header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Volume 104-B, Issue SUPP_10 October 2022 The European Bone and Joint Infection Society (EBJIS) Meeting, Graz, Austria, 8–10 September 2022.

S. Simon B. J. H. Frank A. Aichmair M. Dominkus J. A. Mitterer S. Hartmann M. Kasparek J. Hofstätter

Purpose

Unexpected-positive-intraoperative-cultures (UPIC) in presumed aseptic revision-total-knee-arthroplasties (rTKA) are common, and the clinical significance is not entirely clear. In contrast, in some presumably septic rTKA, an identification of an underlying pathogen was not possible, so called unexpected-negative-intraoperative-cultures (UNIC). The purpose of this study was to evaluate alpha defensin (AD) levels in these patient populations.

Methods

In this retrospective analysis of our prospectively maintained biobank, we evaluated synovial AD levels from 143 rTKAs. The 2018-Musculoskeletal Infection Society score (MSIS) was used to define our study groups. Overall, 20 rTKA with UPIC with a minimum of one positive intraoperative culture with MSIS 2-≥6 and 14 UNIC samples with MSIS≥6 were compared to 34 septic culture-positive samples (MSIS ≥6) and 75 aseptic culture-negative (MSIS 0–1) rTKAs. Moreover, we compared the performance of both AD-lateral-flow-assay (ADLF) and an enzyme-linked-immunosorbent-assay (ELISA) to test the presence of AD in native and centrifuged synovial fluid. Concentration of AD determined by ELISA and ADLF methods, as well as microbiological, and histopathological results, serum and synovial parameters along with demographic factors were considered.


I. K. Sigmund M. Luger R. Windhager M. McNally

Aim

Diagnosing periprosthetic joint infections (PJI) can be very challenging, especially infections caused by low virulence microorganisms. No single test with a 100% accuracy is available yet. Hence, different infection definitions were introduced to improve the diagnostic confidence and quality of research articles. Due to constant developments in this field, infection definitions are adopted continuously. The aim of our study was to find the most sensitive currently available infection definition among three currently used criteria (International Consensus Meeting – criteria 2018 (ICM), Infectious Diseases Society of America - criteria 2013 (IDSA), and European Bone and Joint Infection Society – criteria 2021 (EBJIS)) for the diagnosis of PJI.

Method

Between 2015 and 2020, patients with an indicated revision surgery due to septic or aseptic failure after a total hip or knee replacement were included in this retrospective analysis of prospectively collected data. A standardized diagnostic workup was done in all patients. The components of the IDSA-, ICM-, and EBJIS- criteria for the diagnosis of PJI were identified in each patient.


N. Trebše M. Pokorn

Aim

metagenomic next-generation sequencing (mNGS) has shown to be a useful method for pathogen detection in prosthetic joint infections (PJI). The technique promises to minimize the PJIs without the known causative agent. Our study aimed to compare diagnostic accuracies of cultures and mNGS.

Method

In this study, a meta-analysis following PRISMA recommendations was performed. PubMed and OVID Medline databases were used for article search. The studies using mNGS whole-genome sequencing method and the ones where PJI diagnosis was based on one of the currently recognized criteria were included. Studies were excluded if they comprised less than twenty cases, the ones with insufficient data for the analyses (true positive, true negative, false positive and false negative values for both mNGS and culture results) and publications with strong duplication bias. Univariate metanalysis using a random-effect model has been performed in R studio with a “meta” package. Pooled sensitivity and pooled specificity were calculated.


C. Dupieux A. Dubois C. Loiez H. Marchandin J. P. Lavigne C. Munier E. Chanard V. Gazzano C. Courboulès A. Roux E. Tessier S. Corvec P. Bemer F. Laurent T. Roussel-Gaillard

Aim

Bone and joint infections (BJIs) are serious infections requiring early optimized antimicrobial therapy. BJIs can be polymicrobial or caused by fastidious bacteria, and the patient may have received antibiotics prior to sampling, which may decrease the sensitivity of culture-based diagnosis. Furthermore, culture-based diagnosis can take up to 14 days. Molecular approaches can be useful to overcome these concerns. The BioFire® system performs syndromic multiplex PCR in 1 hour, with only a few minutes of sample preparation. The BioFire® Joint Infection (JI) panel (BF-JI), recently FDA-cleared, detects both Gram-positive (n=15) and Gram-negative bacteria (n=14), Candida, and eight antibiotic resistance genes directly from synovial fluids. The aim of this study was to evaluate its performance in acute JIs in real-life conditions.

Method

BF-JI was performed on synovial fluid from patients with clinical suspicion of acute JI, either septic arthritis or periprosthetic JI, in 6 French centers. The results of BF-JI were compared with the results of culture of synovial fluid and other concomitantly collected osteoarticular samples obtained in routine testing in the clinical microbiology laboratory.


S. Hartmann J. A. Mitterer B. J. H. Frank S. Simon M. Prinz M. Dominkus J. Hofstätter

Aim

Culture-based conventional methods are still the gold standard to identify microorganisms in hip and knee PJIs diagnosis. However, such approach presents some limitations due to prior antimicrobial treatment or the presence of unusual and fastidious organisms. Molecular techniques, in particular specific real-time and broad-range polymerase chain reaction (PCR), are available for diagnostic use in a suspected PJI. However, limited data is available on their sensitivity and specificity.

This study aimed to evaluate the performance of a rapid and simple Investigational Use Only (IUO) version of the BioFire® JI multiplex PCR panel when compared to traditional microbiological procedures.

Method

Fifty-eight native synovial fluid samples were recovered from 49 patients (female n=26; male =23) who underwent one or multiple septic or aseptic revision arthroplasties of the hip (n=12) and knee (n=46). The JI panel methodology was used either on specimens freshly collected (n=6) or stored at −80°C in our Musculoskeletal Biobank (n=52). The JI panel performance was evaluated by comparison with culture reference methods. Patient's medical records were retrieved from our institutional arthroplasty registry as well as our prospectively maintained PJI infection database.


J. Schoenmakers R. Boer L. Gard G. A. Kampinga M. van Oosten J. M. van Dijl P. C. Jutte M. Wouthuyzen-Bakker

Aim

Prompt recognition and identification of the causative microorganism in acute septic arthritis of native and prosthetic joints is vital to increase the chances of successful treatment. The aim of this study was to independently assess the diagnostic accuracy of the multiplex BIOFIRE® Joint Infection (JI) Panel (investigational use only) in synovial fluid for rapid diagnosis

Method

Synovial fluid samples were prospectively collected at the University Medical Center Groningen from patients who had a clinical suspicion of a native septic arthritis, early acute (post-operative, within 3 months after arthroplasty) periprosthetic joint infection (PJI) or late acute (hematogenous) PJI. JI Panel results were compared to culture-based methods as reference standard.


M. Bottagisio M. Viganò L. Zagra A. Pellegrini E. De Vecchi

Aim

The analysis of synovial fluid has proved to be of crucial importance in the diagnostic process of prosthetic joint infections (PJI), suggesting the presence of an infection before the microbiological culture results. In this context, several studies illustrated the efficacy of synovial calprotectin in supporting the diagnosis of PJI [1, 2]. However, several testing methods have been explored to detect synovial calprotectin levels, emphasizing the need to use a standardized, rapid and rapid test.

In this study, synovial calprotectin was analyzed by means of a commercial stool test [3] to explore whether the detected levels might predict PJIs and, therefore, being a promising tool for the fast and reliable diagnosis of this complication.

Method

The synovial fluid of 55 patients underwent to revision of the prosthetic implant were analyzed. The measurement of calprotectin was carried out by of commercial stool test, following the protocol for liquid samples. Calprotectin levels were then compared to other synovial biomarkers of PJI such as leucocyte esterase and count and percentage of polymorphonuclear cells.

Data analysis were performed using R software v4.1.1 (R Core Team) and package “pROC” [4]. Receiver operator characteristics curves were designed using culture test as gold standard to evaluate the area under curve (AUC) of each method (with DeLong method for confidence-interval calculation). Thresholds were calculated to maximize Youden's index; sensitivity and specificity were reported. One-to-one Pearson's correlations coefficient were calculated for each pair of methods. P value <0.05 were considered statistically significant.


A. Busch M. Jäger B. Giebel A. Wegner C. Bielefeld T. Tertel

Aim

Periprosthetic joint infections (PJI) are severe complications after total joint arthroplasty (TJA). Up to now, a gold standard in the diagnostics of PJI is missing. Small extracellular vesicles (sEVs) are secreted by all types of cells and play a key role in immune response in presence of infection (1).

In this prospective study, the diagnostic accuracy of sEVs in the synovial fluid to detect PJI of knee, hip and shoulder joints was investigated. We hypothesized increased surface markers of sEVs in PJI compared to aseptic complications (e.g. implant loosening, stress shielding related pain).

Method

Synovial fluid from 48 patients with painful arthroplasty was examined. The distinction between aseptic and infectious cases was made on the basis of the 2018 Definition of Periprosthetic Hip and Knee Infection (2). 35 (72,9%) probands assigned to aseptic and 13 patients (27,1%) to PJI group. Immuno-fluorescence flow cytometry served to document the concentrations of CD9, CD63, CD66b, CD82 and HLA-DR on sEVs.


S. Klim T. Madl H. Habisch F. Amerstorfer M. Stradner G. Hauer A. Leithner M. Glehr

Aim

The aim of this study was to investigate the metabolomic profile of synovial fluid in periprosthetic joint infection (PJI) cases regarding a possible diagnostic approach. Also, further information about the metabolic composition of synovial fluid in PJI may point to future diagnostic and therapeutic approaches.

Method

Patients with a clinical suspicion of a prosthesis infection who underwent a joint puncture in our outpatient department or ward were included. After sample preparation, the nuclear magnetic resonance (NMR) experiments were performed at 310 K on an AVANCE™ NeoBruker Ultrashield 600 MHz spectrometer. Bruker Topspin version 4.0.2 was used for NMR data acquisition. The spectra for all samples were automatically processed (exponential line broadening of 0.3 Hz), phased, and referenced using TSP at 0.0 ppm. In total, 37 metabolites were analysed using a volume of 200 µl per synovial sample. The PJI and aseptic cases were assigned according to the EBJIS criteria.


V. Sweere J. Sliepen S. Haidari M. Depypere M. Mertens F. IJpma W. Metsemakers G. Govaert

Aim

Fracture-related infection (FRI) is one of the most serious complications in orthopedic trauma surgery [1]. The role of Negative Pressure Wound Therapy (NPWT) remains controversial in the management pathway of FRI [2]. Currently, as scientific evidence is lacking, most recommendations for NPWT with respect to the treatment of FRI are based on expert opinion [3]. The aim of this study was to assess the influence of NPWT and its duration on recurrence of infection in operatively treated FRI patients.

Methods

This is a retrospective cohort study based on the FRI database of three Level 1 Trauma Centres. To be included, patients had to be at least 16 years of age and needed to be surgically treated for FRI between January 1st 2015 and September 1st 2020. Included patients were subdivided in either the NPWT group, or in the control group, when no NPWT had been applied. To avoid confounding, patients were excluded if they (also) underwent NPWT prior to the FRI diagnosis. The relation between the duration of NPWT during FRI treatment and the recurrence rate of infection was analyzed using a multivariable logistic regression model.


N. Kristensen J. Lange T. Frøslev A. B. Pedersen

Aim

To investigate the incidence and time-trend in reoperation due to deep Surgical Site Infection (SSI) following hip fracture surgery.

Method

This was a population-based, nationwide, cohort study. We included 74,771 from the Danish Multidisciplinary Hip Fractures Register (1) consisting of patients 65 years of age or older, who underwent surgery between January 1st 2005 and December 31st 2016 for all types of hip fracture. Cross-linkage with the Danish National Patient Register and The Danish Civil Registration system was made.

Demographic data extracted included vital status, civil status, gender, age, Body Mass Index (BMI), fracture classification (AO/OTA 31A-C) and surgical procedures binary registered as joint replacement or internal fixation, Charlson comorbidity index (CCI) and secondary diseases not included in CCI. Outcome was reoperations due to deep SSI in accordance with the definition from Centre for Disease Control (2). We computed cumulative incidence rates and risk ratios (RR) by calendar year periods and by different risk factors, considering death as competing risk and adjusting for age, gender, CCI, fracture type and surgery type.


A. F. Fes A. C. Leal A. Alier S. L. Pardos M. L. S. Redó L. P. Verdié S. M. Diaz D. Pérez-Prieto

Aim

The most frequent mechanical failure in the osteosynthesis of intertrochanteric fractures is the cut-out. Fracture pattern, reduction quality, tip-apex distance or the position of the cervico-cephalic screw are some of the factors that have been associated with higher cut-out rates. To date, it has not been established whether underlying bacterial colonization or concomitant infection may be the cause of osteosynthesis failure in proximal femur fractures (PFF). The primary objective of this study is to assess the incidence of infection in patients with cut-out after PFF osteosynthesis.

Method

Retrospective cohort study on patients with cut-out after PFF osteosynthesis with endomedullary nail, from January 2007 to December 2020. Demographic data of patients (such as sex, age, ASA), fracture characteristics (pattern, laterality, causal mechanism) and initial surgery parameters were collected (time from fall to intervention, duration of surgery, intraoperative complications). Radiographic parameters were also analyzed (tip-apex distance and Chang criteria). In all cut-out cases, 5 microbiological cultures and 1 anatomopathological sample were taken and the osteosynthesis material was sent for sonication. Fracture-related infection (FRI) was diagnosed based on Metsemakers et al (2018) and McNally et al (2020) diagnostic criteria.


R. Corrigan M. Dudareva J. Sliepen M. Wouthuyzen R. Rentenaar F. Ijpma F. Hietbrink B. Atkins G. Govaert M. McNally

Aim

Fracture related infection (FRI) is classically defined as early (0–2 weeks), delayed (3–10 weeks) or late (>10 weeks). Treatment strategies reflect this, particularly with debridement and implant retention (DAIR), but there is little evidence to support this. This multinational study clarified the relationship between pathogens isolated and time from injury.

Methods

All confirmed FRI cases, managed surgically, at three hospitals were included. Data were analyzed on patient demographics, time from injury and pathogens isolated. Patients who underwent DAIR were also analyzed separately.


J. Sliepen M. Depypere J. Onsea Y. Debaveye G. Govaert F. Ijpma W. Zimmerli W. Metsemakers

Purpose

Fracture-related infection (FRI) is an important complication related to orthopaedic trauma. Although the scientific interest with respect to the diagnosis and treatment of FRI is increasing, data on the microbiological epidemiology remains limited. Therefore, the primary aim of this study was to evaluate the microbiological epidemiology related to FRI, including the association with clinical symptoms and antimicrobial susceptibility data. The secondary aim was to analyze whether there was a relationship between the time to onset of infection and the microbiological etiology of FRI.

Methods

Over a five-year period, FRI patients treated at the University Hospitals of Leuven, Belgium, were retrospectively included. The microbiological etiology and antimicrobial susceptibility data were analyzed. Patients were classified as having an early (<2 weeks after implantation), delayed (2–10 weeks) or late-onset (> 10 weeks) FRI.


A. Loro

Aim

In recent years, the number of victims of road traffic accidents (RTAs) and resulting surgeries have been on the rise in low income countries. Treatments are often long and costly; resources required to treat fracture related infections (FRI) continue to be a limiting factor in low income countries and standardized management protocols are lacking. This retrospective study reports our facility's experience of femoral FRI management in a low income country and evaluates the surgical outcomes with a minimum follow up of five years.

Methods

The clinical and radiographic records of patients who underwent surgery for femoral FRI in our facility between 2005–2016 were analyzed. Twenty-six patients were included (15 males), with a median age of 29 years (range 4–71). The initial fracture was caused by RTA in 22 patients, gunshot in 2, accidental fall in 1 and acute osteomyelitis in 1. Polytrauma was observed in 10. All patients but one were referred for limb reconstruction from other institutions. Surgical treatment was instituted in all: site debridement (SD) alone was performed in 2 patients; SD and hardware removal in 4; SD and external fixation in 4; SD, hardware removal and external fixation in 16. In this latter group, complex treatments such as bone transport (BT) and vascularized fibula flap (VFF) were utilized in 4 and 3 patients respectively.


F. Loïc M. Kennedy N. Denis N. F. Olivier N. Y. M. Ange T. Ulrich H. E. Daniel

Introduction

Open tibial fractures (OTF) rank first among lower limb fractures in sub-Saharan Africa and bone infection remains the main challenge. The aim of this study was to identify the factors associated with chronic bone infection after OTF in a limited-resource setting.

Methods

Patients aged 18 years and older, who underwent OTF treatment in a tertiary care hospital during the period from December 2015 to December 2020 were included in this retrospective study. Patients were contacted via phone calls and invited for a final clinical and radiological evaluation. Patients who met diagnostic criteria of chronic osteomyelitis were identified. Logistic regression was used to determine the predictive factors of OTF related chronic osteomyelitis.


S. Vittrup P. Hanberg M. B. Knudsen S. Tøstesen J. O. Kipp J. Hansen N. P. Jørgensen M. Stilling M. Bue

Aim

Prompt and sufficient broad spectrum empirical antibiotic treatment is key to prevent infection following open tibial fractures. Succeeding co-administration, we dynamically assessed the time for which vancomycin and meropenem concentrations were above relevant epidemiological cut-off minimal inhibitory concentrations (T>MIC) in tibial compartments for the bacteria most frequently encountered in open fractures. Low and high MIC-targets were applied: 1 and 4 µg/mL for vancomycin and 0.125 and 2 µg/mL for meropenem.

Materials and methods

8 pigs received a single dose of 1000 mg vancomycin and 1000 mg meropenem simultaneously over 100 min and 10 min, respectively. Microdialysis catheters were placed for sampling over 8 h in tibial cancellous bone, cortical bone, and adjacent subcutaneous adipose tissue. Venous blood samples were collected as references.


M. Veloso M. Bernaus M. Lopez A. A. de Nova P. Camacho M. A. Vives M. I. Perez D. Santos J. E. Moreno A. Auñon L. Font-Vizcarra

Aim

The treatment of fracture-related infections (FRI) focuses on obtaining fracture healing and eradicating infection to prevent osteomyelitis. Treatment guidelines include removal, exchange, or retention of the implants used according to the stability of the fracture and the time from the infection. Infection of a fracture in the process of healing with a stable fixation may be treated with implant retention, debridement, and antibiotics. Nonetheless, the retention of an intramedullary nail is a potential risk factor for failure, and it is recommended to exchange or remove the nail. This surgical approach implies additional life-threatening risks in elderly fragile hip fracture patients.

Our study aimed to analyze the results of implant retention for the treatment of infected nails in elderly hip fracture patients.

Methods

Our retrospective analysis included patients 65 years of age or older with an acute fracture-related infection treated with implant retention from 2012 to 2020 in 6 Spanish hospitals with a minimum 1-year follow-up. Patients that required open reduction during the initial fracture surgery were excluded. Variables included in our analysis were patient demographics, type of fracture, date of FRI diagnosis, causative microorganism, and outcome. Treatment success was defined as fracture healing with infection eradication without the need for further hospitalization.


H. M. Schenk M. Sebillotte J. Lomas A. Taylor E. Benavent O. Murillo M. Fernandez-Sampedro K. Huotari C. Aboltins R. Trebse A. Soriano M. Wouthuyzen-Bakker

Aim

Patients with late acute periprosthetic joint infections (PJI) and treated with surgical debridement have a high failure rate. Previous studies have shown that rheumatoid arthritis (RA) is an independent risk factor for treatment failure. We conducted a case-control study to identify predictors for failure in late acute PJI treatment in RA patients. We hypothesize that patients with RA have a higher failure rate compared to controls due to the use of immunosuppressive drugs.

Method

Data of an international multicenter retrospective observational study was used. Late acute PJI was defined as a sudden onset of symptoms and signs of a PJI, more than 3 months after implantation. Failure of treatment was defined as persistent signs of infection, relapse with the same or reinfection with a different micro-organism, need for prosthesis removal or death. Cases with RA were matched with cases without RA based on the affected joint. A Cox survival analyses, stratified for RA, was used to calculate hazard ratio's (HR) for failure. Subgroup analyses were used to explore other predictors for treatment failure in RA patients.


H. Scheper R. Van der Wal R. Mahdad S. Keizer N. Delfos J. Van der Lugt K. E. Veldkamp P. Nolte E. Schippers H. Wattel L. G. Visser R. Nelissen M. G.J. De Boer

Background

Treatment of staphylococcal prosthetic joint infection (PJI) usually consists of surgical debridement and prolonged rifampicin combination therapy. Tailored antimicrobial treatment alternatives are needed due to frequent side effects and drug-drug interactions with rifampicin combination therapy. We aimed to assess the effectiveness of several alternative antibiotic strategies in patients with staphylococcal PJI.

Methods

In this prospective, multicenter registry-based study, all consecutive patients with a staphylococcal PJI, treated with DAIR or one-stage revision surgery between January 1st, 2015 and November 3rd, 2020, were included. Patients were treated according to a predefined protocol for PJI. Antimicrobial treatment strategies differed between centers, which was accepted and used as pseudorandomization. Depending on the hospital patients were admitted to, they were treated with either a long-term rifampicin strategy (consisting of 12 weeks rifampicin combination therapy) ore one of several short-term rifampicin strategies, consisting of only five days of rifampicin combination treatment, started immediately postoperative, followed by clindamycin, flucloxacillin or vancomycin monotherapy. Patients were stratified in different groups, depending on the used antimicrobial strategy. Cox proportional hazards models were used to compare outcome between the groups.


A. A. Rubio L. F. Vizcarra M. V. Durán M. B. Johnson M. M. Oleaga N. H. González A. A. de Nova J. B. Oliete J. C. Robles R. R. Sayol J. C. M. Pastor A. Alías L. Boadas E. M. Mahamud M. S. Martos

Aim

To describe the impact of a failed DAIR in the further prognosis of the prosthesis after a PJI

Method

A retrospective multicentrically study was conducted, including 10 institutions from all over the country. PJI-confirmed patients who underwent DAIR clinical records were revised. Age, sex, relevant previous conditions, Charlson comorbidity score, previous surgery, PJI diagnosis and surgical and antibiotic treatment, from the index surgery onwards. DAIR failure was defined as the removal of the prosthesis and/or an antibiotic suppressive treatment.


B. J.H. Frank A. Aichmair S. Hartmann S. Simon M. Dominkus J. Hofstätter

Aim

Analysis of microbiological spectrum and resistance patterns as well as the clinical outcome of patients who underwent a Debridement, antibiotics and implant retention (DAIR) procedure in the early phase following failed two-stage exchange arthroplasty of the knee and hip.

Method

Of 312 patients treated with two-stage exchange arthroplasty between January 2011 and December 2019, 16 (5.1%) patients (9 knee, 7 hip) underwent a DAIR procedure within 6 months following second stage. We retrospectively analyzed the microbiological results as well as changes in the microbiological spectrum and antibiotic resistance patterns between stages of two-stage exchange arthroplasties and DAIR procedures. Patient's re-revision rates after a minimum follow-up of 12 months following DAIR procedure were evaluated. Moreover, differences between knee and hip and between infected primary total joint replacement (TJRs) and infected revision TJRs as well as patient's host factors and microbiological results regarding the outcome of DAIR were analyzed.


T. Ferry C. Kolenda T. Briot A. Conrad S. Lustig C. Cassino F. Laurent C. Batailler

Background

Exebacase, an antistaphylococcal lysin in Phase 3 of development as a treatment for S. aureus bacteremia/right-sided endocarditis has demonstrated antibiofilm activity in vitro and has previously been used as salvage therapy in four patients with relapsing multidrug-resistant (MDR) S. epidermidis knee prosthetic joint infection (PJI) using a procedure called LysinDAIR (administration of the lysin during the performance of an arthroscopic DAIR).

Materials/methods

We performed a single center, exploratory, open-label prospective study using the LysinDAIR procedure in patients with chronic (inoculation >3 months prior to treatment) coagulase-negative staphylococci (CNS) PJI of the knee with two different clinical presentations and treatment paradigms. Cohort A: first episode of CNS knee PJI, for whom the LysinDAIR was followed by clindamycin + levofloxacin planned to be prescribed for three months and then stopped; and Cohort B: relapsing episodes of MDR CNS knee PJI for whom the LysinDAIR was followed by primary antimicrobial therapy for three months, followed by suppressive antimicrobial therapy (SAT). Exebacae susceptibility testing was performed before treatment for each patient. In agreement with the French Health authority, exebacase (2 to 3.5 total mg in 30–50 ml (∼0.067 – 0.075 mg/m) was administered directly into the joint during arthroscopy.


M. Petrie S. Panchani M. A. Einzy D. Partridge T. Harrison I. Stockley

Aim

The duration of systemic antibiotic therapy following first-stage surgery is contentious. Our Institution's philosophy is to perform an aggressive debridement, use high concentration targeted antibiotics through cement beads and systemic prophylactic antibiotics alone. In the presence of significant soft tissue infection or microbiological diagnostic uncertainty; systemic antibiotics may be prescribed for 5 days whilst awaiting tissue culture results. The aim of this study was to assess the success of our philosophy in the management of PJI of the hip using our two-stage protocol.

Method

A retrospective review of our Institution's prospectively-collected database was performed to identify those patients who were planned to undergo a two-stage hip revision procedure for PJI. All patients had a confirmed diagnosis of PJI as per the major criteria of MSIS 2013, a minimum 5-years follow up and were assessed at the time of review using the MSIS working group outcome-reporting tool (2018). They were then grouped into “successful” or “unsuccessful” (suppressive antibiotics, further revision for infection, death within 1 year).


M. Casali N. Rani I. Cucurnia M. Filanti V. Coco D. Reale P. Zarantonello C. Musiani M. Zaffagnini M. Romagnoli

Aim

Aim of this monocentric, prospective study was to evaluate the safety, efficacy, clinical and radiographical results at 24-month follow-up (N = 6 patients) undergoing hip revision surgery with severe acetabular bone defects (Paprosky 2C-3A-3B) using a combination of a novel phase-pure betatricalciumphosphate - collagen 3D matrix with allograft bone chips.

Method

Prospective follow-up of 6 consecutive patients, who underwent revision surgery of the acetabular component in presence of massive bone defects between April 2018 and July 2019. Indications for revision included mechanical loosening in 4 cases and history of hip infection in 2 cases. Acetabular deficiencies were evaluated radiographically and CT and classified according to the Paprosky classification. Initial diagnosis of the patients included osteoarthritis (N = 4), a traumatic fracture and a congenital hip dislocation. 5 patients underwent first revision surgery, 1 patient underwent a second revision surgery.


G. Vles J. Bossen J. Kloos P. Debeer S. Ghijselings

Aim

A septic revision of an artificial joint is routinely split up in a so-called dirty phase and a clean phase. The measures taken to initiate the start of the clean phase vary significantly between musculoskeletal infection centers. We performed simulations of one-step exchanges of infected THAs and sought to 1) determine the effect of different clean phase protocols on the sterile field, and 2) determine whether or not it is possible to re-implant the new prosthesis completely clean.

Method

Nine fresh frozen cadaveric hips were used and primary THA was undertaken via a direct anterior approach. Before implantation of the components varying amounts of fluorescent powder (GloGerm) were deposited, simulating bacterial infection. Second, a one-step exchange was performed via a posterolateral approach. After implant removal, debridement, and lavage, randomization determined which clean phase protocol was followed, i.e. no, some or full additional measures. Finally, the new prosthesis was re-implanted (fig. 1).

In order to determine the effect of different clean phase protocols on contamination of the sterile field standardized UV light-enhanced photographs were obtained of 1) the gloves, 2) the instrument table, 3) the drapes, and 4) the wound and these were ranked on cleanliness by a blind panel of hip surgeons.

In order to determine whether or not it is possible to re-implant the prosthesis completely clean, the implant was taken out again at the end of the one-step exchange and inspected for contamination under UV light.


S. Vittrup L. K. Jensen P. Hanberg J. Slater M. A. Hvistendahl M. Stilling N. Jørgensen M. Bue

Aim

This study investigated if co-administration of rifampicin with moxifloxacin led to a decrease in moxifloxacin concentrations in relevant tissues in a porcine model of implant-associated osteomyelitis caused S. aureus. Pharmacokinetics were measured using microdialysis and treatment effect was measured by quantifying bacterial load from implant and periprosthetic bone following a 1-stage revision and antibiotics.

Method

15 female pigs received a stainless-steel implant in the right proximal tibia and were randomized into two groups. Infection was introduced by inoculating the implant with Staphylococcus aureus as previously described1. On day 7 post surgery, all pigs were revised with implant removal, debridement of implant cavity and insertion of a sterile implant. 7 days of treatment was then initiated with either moxifloxacin 400 mg iv q.d. (M) or moxifloxacin and rifampicin 450 mg iv b.i.d. (RM). At day 14, animals were sedated and microdialysis was applied for continuous sampling of moxifloxacin concentrations during 8 h in five compartments: the implant cavity, cancellous bone in both the infected and non-infected proximal tibia, and adjacent subcutaneous tissue on both the infected and non-infected side using a previously described setup2. Venous blood samples were collected. Implant and adjacent bone were removed for analysis.


G. Mannala M. Rupp V. Alt

Aim

Galleria mellonella larvae is a well-known insect infection model that has been used to test the virulence of bacterial and fungal strains as well as for the high throughput screening of antimicrobial compounds against infections. Recently, we have developed insect infection model G. mellonella larvae to study implant associated biofilm infections using small K-wire as implant material. Here, we aimed to further expand the use of G. mellonella to test other materials such as bone cement with combination of gentamicin to treat implant-associated infections.

Method

The poly methyl methacrylate (PMMA) with and without gentamicin and liquid methyl methacrylate (MMA) were kindly provided by Heraeus Medical GmbH, Wehrheim. To make the bone cement implants as cubes, Teflon plate (Karl Lettenbauer, Erlangen) with specified well size was used. The Radiopaque polymer and monomer were mixed well in a bowl, applied over on to the Teflon plate and pressed with spatula to form fine and uniform cubes. After polymerization, the bone cement implants were taken out of the Teflon well plate with the help of pin. For the infection process, bone cement cubes were pre-incubated with S. aureus EDCC 5055 culture at 5×106 CFU/ml for 30 min at 150 rpm shaking conditions. Later, these implants were washed with 10ml PBS and implanted in the larvae as mentioned. Survival of the larvae were observed at 37°C in an incubator. To analyze the susceptibility of the bacterial infections towards gentamicin, survival of the larvae compared with control group implanted only with bone cement. The effect of gentamicin was also measured in terms of S. aureus load in larvae on 2nd day. SEM analysis was performed to see the effect of gentamicin on biofilm formation on bone cement.


M. Ibrahim T. Mah H. Abdelbary

Introduction

Gram-negative prosthetic joint infections (GN-PJI) present unique challenges in management due to their distinct pathogenesis of biofilm formation on implant surfaces. The purpose of this study is to establish a clinically representative GN-PJI model that can reliably recapitulate biofilm formation on titanium implant surface in vivo. We hypothesized that biofilm formation on an implant surface will affect its ability to osseointegrate.

Methods

The model was developed using 3D-printed titanium hip implants, to replace the femoral head of male Sprague-Dawley rats. GN-PJI was induced using two bioluminescent Pseudomonas aeruginosa strains: a reference strain (PA14-lux) and a mutant biofilm-defective strain (ΔflgK-lux). Infection was monitored in real-time using the in vivo imaging system (IVIS) and Magnetic Resonance Imaging (MRI). Bacterial loads on implant surface and in periprosthetic tissues were quantified utilizing viable-colony-count. Field-emission scanning-electron-microscopy of the explanted implants was used to visualize the biofilm formation at the bone-implant-interface. The implant stability, as an outcome, was directly assessed by quantifying the osseointegration in vitro using microCT scan, and indirectly assessed by identifying the gait pattern changes using DigiGaitTM system in vivo.


L. K. Jensen H. E. Jensen S. A. Blirup M. Bue P. Hanberg S. Soto B. Aalbaek M. Arkas M. Vardavoulias

Aim

To develop a new system for antibacterial coating of joint prosthesis and osteosynthesis material. The new coating system was designed to release gentamicin immediately after insertion to eradicate surgical contamination.

Method

Steel implants (2×15mm) were coated with a solid nanocomposite xerogel made from silica and the dendritic polymer, hyperbranched polyethyleneimine. The xerogel was anchored inside a porous surface made by pre-coating with titanium microspheres. Finally, gentamicin was encapsulated in the xerogel, i.e. no chemical binding. A total of 50 µg gentamicin was captured into each implant. The efficacy of the new coating was evaluated in a porcine model of implant associated osteomyelitis. In total, 30 female pigs were randomized into 3 study groups (n=10). Group A; plain implants + saline, Group B; plain implants + 104 CFU of Staphylococcus aureus, and Group C; coated implants + 104 CFU of S. aureus. Implant + inoculum was placed into a pre-drilled implant cavity of the right tibia and the pig was euthanized 5 days afterwards. Postmortem microbiology and pathology were performed. Two additional pigs were used in a pharmacokinetic study where microdialysis (MD) catheters were placed alongside coated implants. Extracellular fluid was sampled regularly for 24 hours from the MD catheters and analyzed for gentamicin content.


B. v. Dijk F. H. v. Duyvenbode L. de Vor F. R. H. A. Nurmohamed M. Lam A. Poot R. Ramakers S. Koustoulidou F. Beekman J. v. Strijp S. Rooijakkers E. Dadachova H. C. Vogely H. Weinans B. C.H. van der Wal

Aim

Implant infections caused by Staphylococcus aureus are difficult to treat due to biofilm formation, which complicates surgical and antibiotic treatment. Herewith we introduce an alternative approach using monoclonal antibodies (mAbs) targeting S. aureus and provide the biodistribution and specificity in a mouse implant infection model.

Methods

4497-IgG1targeting S. aureus Wall Teichoic Acid was labeled to Indium-111 using “CHXA” as a chelator. SPECT-CT scans were performed at 24, 72 and 120 hours after administration in Balb/cAnNCrl mice with a subcutaneous implant pre-colonized with biofilm of S. aureus. Biodistribution over the various organs of this labelled antibody was visualized and quantified using SPECT-CT imaging and compared to uptake at the target tissue with implant infection.


S. Tøstesen M. Stilling P. Hanberg T. M. Thillemann T. Falstie-Jensen M. Tøttrup M. Knudsen E. T. Petersen M. Bue

Aim

Deadspace is the tissue and bony defect in a surgical wound after closure. This space is presumably poorly perfused favouring bacterial proliferation and biofilm formation. In arthroplasty surgery, an obligate deadspace surrounding the prosthesis is introduced and deadspace management, in combination with obtaining therapeutic prophylactic antibiotic concentrations, is important for limiting the risk of acquiring a periprosthetic joint infection (PJI). This study aimed to investigate cefuroxime distribution to an orthopaedic surgical deadspace in comparison with plasma and bone concentrations during two dosing intervals (8 h × 2).

Method

In a setup imitating shoulder arthroplasty surgery, but without insertion of a prosthesis, microdialysis catheters were placed for cefuroxime sampling in a deadspace in the glenohumeral joint and in cancellous bone of the scapular neck in eighteen pigs. Blood samples were collected from a central venous catheter as a reference. Cefuroxime was administered according to weight (20 mg/kg). The primary endpoint was time above the cefuroxime minimal inhibitory concentration of the free fraction of cefuroxime for Staphylococcus aureus (fT > MIC (4 µg/mL)).


T. Ferry C. Kolenda T. Briot F. Craighero A. Conrad S. Lustig C. Bataillers F. Laurent

Background

Bacteriophages are natural viruses of interest in the field of PJI. A paper previously reported the PhagoDAIR procedure (use of phages during DAIR) in three patients with PJI for whom explantation was not desirable. As the need to isolate the pathogen before surgery to perform phage susceptibility testing is a strong hindrance for the development of this procedure, we developed post-operative phage injections using ultrasound, in patients infected with S. aureus and/or P. aeruginosa who were eligible for the PhagoDAIR procedure, but for whom phages were not available at the time of surgery.

Materials/Methods

We performed a single center, exploratory, prospective cohort study including patients with knee PJI who received phage therapy with ultrasound after performance of a DAIR or a partial prosthesis exchange. All patients had PJI requiring conservative surgery and suppressive antimicrobial therapy (SAT) as salvage procedure. Each case was discussed in multidisciplinary meetings in agreement with French health authority, based on the clinical presentation, and the phage susceptibility testing. The cocktail of highly concentrate active phages (5 mL; about 10e9 PFU/mL) was extemporaneous prepared and administered three times directly into the joint using sonography (1 injection per week during 3 weeks) during the postoperative period, before switching antibiotics to SAT.


M. Dudareva R. Corrigan A. Hotchen R. Muir C. Scarborough M. Kumin B. Atkins M. Scarborough M. McNally G Collins

Aim

Smoking is known to impair wound healing and to increase the risk of peri-operative adverse events and is associated with orthopaedic infection and fracture non-union. Understanding the magnitude of the causal effect on orthopaedic infection recurrence may improve pre-operative patient counselling.

Methods

Four prospectively-collected datasets including 1173 participants treated in European centres between 2003 and 2021, followed up to 12 months after surgery for clinically diagnosed orthopaedic infections, were included in logistic regression modelling with Inverse Probability of Treatment Weighting for current smoking status [1–3]. Host factors including age, gender and ASA score were included as potential confounding variables, interacting through surgical treatment as a collider variable in a pre-specified structural causal model informed by clinical experience. The definition of infection recurrence was identical and ascertained separately from baseline factors in three contributing cohorts. A subset of 669 participants with positive histology, microbiology or a sinus at the time of surgery, were analysed separately.


O. Thompson A. W-Dahl A. Stefánsdóttir

Background

Periprosthetic joint infection (PJI) following total knee arthroplasty (TKA) is a severe complication in terms of disability, morbidity, and cost. We performed a study to investigate whether early PJI (within 90 days of primary TKA) is associated with increased mortality. Secondary aims were to compare mortality rates over time and between surgical treatment methods.

Methods

Patients with suspected PJI were identified by linkage of the Swedish Knee Arthroplasty Register (SKAR) and the Swedish Prescribed Drug Register (SPDR) in 2007–2008 and 2012–2013. Medical records of patients receiving more than 4 weeks of continuous antibiotic therapy were subsequently reviewed to verify the PJI diagnosis. Information on mortality was obtained through the SKAR which is updated daily from the tax agency and patients with PJI were compared to patients without PJI.


C. Minea A. A. Rubio J. E. Moreno J. J. A. Correa

Aim

Prosthetic joint replacement is more commonly done in the elderly group of patients due to an increase pathology related to joint degeneration that comes with age. In this age group is also more frequent having underling condition that may predispose to a prosthetic joint infection. Also, the pharmacological intervention in those patients may play an important role as a risk factor for infection after joint replacement surgery. The use of oral anticoagulants seems to be particularly increased in elderly patients but there aren't enough data published to support an association between prosthetic joint infection and the use of oral anticoagulants.

Identifying risk factors in elderly patients age >75 years old with a special focus on the oral anticoagulation therapy is the aim of the study.

Methods

In a retrospective study from 2011 till 2018 all the patients >75 years old with knee and hip replacement surgery have been review looking for acute prosthetic infection and risk factors that may be predispose to it. Patients with previous surgery or any other mechanical complication that needed intervention on the same area have been excluded.


O. Lutro S. Mo T. H. Leta A. M. Fenstad M. B. Tjørhom T. Bruun G. Hallan O. Furnes H. Dale

Aim

In recent years, many studies on revision for infection after arthroplasty have been published. In national arthroplasty registers, revision for infection is defined as surgical debridement, with or without removal or exchange of the entire or parts of the prosthesis due to deep infection, and should be reported to the register immediately after surgery. The diagnosis of infection is made at the surgeon's discretion, based on pre- and perioperative assessment and evaluation, and is not to be corrected to the register based on peroperative bacterial cultures. Due to this lack of validation, the rate of revision for infection will only be an approximation of the true rate of periprosthetic joint infection (PJI). Our aim was to validate the reporting of infection after total hip arthroplasty, and to assess if revisions for infection actually represented true PJI.

Methods

We investigated the reported revisions for infection and aseptic loosening after total hip arthroplasty from 12 hospitals, representing one region of the country, reported during the period 2010–2020. The electronic patient charts were investigated for information on surgical treatment, use of antibiotics, biochemistry and microbiology findings. PJI was defined as growth of at least two phenotypically identical microbes in perioperative tissue samples. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated.


M. Coppeaux D. Popescu M. Julie H. Poilvache R. B. Mbuku V. C. Maïte J. Yombi O. Cornu

Introduction

The surgical management of late PJI was usually done in two stages with the placement of a temporary cement spacer. The development of one-stage surgical care raises questions about the two-stage strategy. The objectives of this study are to identify the complications related to the presence of the cement spacer within a two-stage strategy. The septic recurrence rate is also evaluated after a minimum follow-up of two years.

Material and methods

Medical files of 208 patients (101 knees and 107 hips) who underwent a two-stage revision for late PJI prosthesis infection were retrospectively reviewed. Antibiotic loaded articulated homemade cement spacers were used. Second stage was usually planned on average 4 to 6 weeks after the first stage. Patients were allowed to walk without loading. The success rate was defined as the absence of septic recurrence after a minimum follow-up of two years. Descriptive statistics and uni- and multivariate analysis were conducted.


C. Vargas-Reverón A. Soriano J. Fernandez-Valencia J. C. Martinez-Pastor L. Morata E. Muñoz-Mahamud

Aim

Our aim was to evaluate the prevalence and impact of unexpected intraoperative cultures on the outcome of total presumed aseptic knee and hip revision surgery.

Method

Data regarding patients prospectively recruited in our center, who had undergone elective complete hip and knee revision surgery from January 2003 to July 2017 with a preoperative diagnosis of aseptic loosening was retrospectively reviewed. Partial revisions and patients with follow up below 60 months were excluded from the study. The protocol of revision included at least 3 intraoperative cultures. Failure was defined as the need for re-revision due to any-cause at 5 years and/or the need for antibiotic suppressive therapy.


K. Ottink D. Dorleijn M. Wouthuyzen-Bakker

Background

A few patients undergoing a total hip replacement need a subsequent revision of the cup. In some of these cases, the treating surgeon may be confronted with Unexpected Positive Intraoperative Cultures (UPIC). The exact incidence of this finding is unclear. Moreover, it is unknown what the clinical outcome of these patients is when the stem is left in situ. The aim of our study was to describe the incidence of UPIC in patients undergoing cup revision and to determine the need for total revision in this patient group during follow-up.

Methods/design

In this retrospective multicenter cohort study, we included all consecutive patients that underwent a cup revision between 2015–2017 and had a minimal follow-up of 2 years. Patients were divided in 3 cohorts: i) no positive intra operative cultures; ii) one UPIC; iii) two or more UPIC. Cases in whom 2 or fewer cultures were obtained during cup revision were excluded from the analysis.


A. Ribau M. Budin L. Zanna F. Dasci T. Gehrke M. Citak

Aim

The prevalence of unexpected positive cultures (UPC) in aseptic revision surgery of the joint with a prior septic revision procedure in the same joint remain unknown. The purpose of this study was to determine the prevalence of UPC in aseptic revisions performed in patients with a previous septic revision in the same joint. As secondary outcome measure, we explore possible risk factors associated with UPC and the re-revision rates.

Method

This retrospective single-center study includes all patients between January 2016 and October 2018 with an aseptic revision total hip or knee arthroplasty procedure with a prior septic revision in the same joint. Patients with less than three microbiology samples, without joint aspiration or with aseptic revision surgery performed <3 weeks after a septic revision were excluded. UPC was defined as a single positive culture in a revision that the surgeon had classified as aseptic according to the 2018 International Consensus Meeting.


J. Goosen W. V. D. Weegen W. Rijnen J. V. Eck W. Liu

Aim

To date, the value of culture results after a debridement, antibiotics and implant retention (DAIR) for early (suspected) prosthetic joint infection (PJI) as risk indicators in terms of prosthesis retention is not clear. At one year follow-up, the relative risk of prosthesis removal was determined for culture-positive and culture-negative DAIRs after primary total hip or knee arthroplasty. The secondary aim was to explore differences in patient characteristics, infection characteristics and outcomes between these two groups.

Methods

A retrospective regional registry study was performed in a group of 359 patients (positive cultures: n = 299, negative cultures n = 60) undergoing DAIR for high suspicion of early PJI in the period from 2014 to 2019. Differences in patient characteristics, deceased patients and number of subsequent DAIRs between the positive and negative DAIR groups were analyzed using independent t-tests, Mann-Whitney, Pearson's Chi-square tests and Fisher's Exact tests.


K. Moore A. Li N. Gupta B. Price C. Delury P. Laycock S. Aiken P. Stoodley

Aim

Multispecies biofilms are associated with difficult periprosthetic joint infections (PJI), particularly if they have different antibiotic sensitivities. We aimed to determine if we could generate and kill a multispecies biofilm consisting of a Gram negative and Gram positive pathogen in-vitro with antibiotic loaded calcium sulfate beads containing single or combination antibiotics.

Methods

To establish whether we could co-culture mixed species biofilms various combinations of Pseudomonas aeruginosa (PA), Enterococcus faecalis (EF), Staphylococcus aureus (SA) and Enterobacter faecalis (EF) were grown together on 316L stainless steel coupons and agar plates. Based on this screen we focused on PA + EF and challenged them with high purity calcium sulfate beads (Stimulan Rapid Cure) loaded with vancomycin (V), alone tobramycin (T) alone or vancomycin and tobramycin in combination (V+T). Bioluminescence, light imaging, plate count, confocal microscopy and scanning electron microscopy were used to quantify growth.


B. Young M. Dudareva M. Vicentine A. Hotchen M. McNally

Aim

Local antibiotic treatment for bone and joint infections offers direct delivery of high concentrations of antibiotics with reduced systemic exposure and favourable safety profile. However, the possibility of prolonged release of antibiotics at sub-therapeutic levels creates concern about the possible development of antimicrobial resistance.

We investigated patients with recurrent bone and joint infection for evidence of antimicrobial resistance emerging from the use of local antibiotics.

Method

125 patients with recurrent infection (prosthetic joint infection, fracture related infection and osteomyelitis) in the UK between 2007 and 2021 were identified. Electronic patient records (including operative notes, pathology results and prescriptions) were reviewed to extract site of infection, date of surgery, the use of local antibiotics, culture results, empiric and definitive antibiotic therapy. All antibiotic sensitivity results were recorded as sensitive, intermediate or resistant according to contemporary guidelines (BSAC and EUCAST).


A. F. Fes A. P. Pol D. Pérez-Prieto P. H. Gomez A. Alier L. P. Verdié J. C. M. Garcia

Aim

One of the most severe complications of primary total knee arthroplasty (TKA) is periprosthetic joint infection (PJI). Nowadays, the use of antibiotic-loaded cement for prevention of infection is still controversial. The aim of the present study is to evaluate the use of an antibiotic-loaded cement to reduce the infection rate in primary total knee arthroplasty.

Method

Prospective randomized study, with 2893 cemented total knee arthroplasties performed between 2005 and 2010 in our institution. Two different groups were formed depending on which bone cement was used, without antibiotic (the control group) or loaded with erythromycin and colistin (the study group). All patients received the same systemic prophylactic antibiotics. The patients were followed for a minimum of twelve months. The rate of infection was analyzed according to the criteria of the Centers for Disease Control and Prevention (CDC).


G. Porcellini A. Giorgini M. Montanari

Aim

Studies have shown that retention of antibiotic cement spacer in selected elderly patients with low functional demand represents a viable option for periprosthetic joint infections (PJI) treatment1,2.

The aim of this study is to compare the efficacy in infection treating among modular taylored preformed and hand-made antibiotic spacers. Our hypothesis is that modular tailored preformed spacer provides a better rate of infection resolution, better radiological and functional outcomes compared to hand-made spacers.

Materials and methods

We identified 48 patients treated with antibiotic cement spacer for shoulder chronic infection between 2015 and 2021 in our institution; (13 hand-made spacers and 35 modular tailored preformed spacers). We collected data about comorbidities, associated microorganism, infection resolution, clinical and radiographic evaluation.


F. D. Meo G. Cacciola A. Bruschetta P. Cavaliere

Aim

The aim of this study is to evaluate if the gentamycin elution from bone cement is influenced by the timing of application of the antibiotic powder.

Method

This was an experimental in vitro study that compared the elution properties of different formulation of gentamycin from a commercially available hip, knee and shoulder cement spacers. Four different experimental models were prepared. Five different spacers were prepared for each experimental mode and for each joint. We compared four different formulation of cement spacers: spacer #1, in which the spacer was prepared with a premixed bone-cement antibiotic mixture; spacer #2, in which the spacer was prepared by adding antibiotic powder to the bone cement at the time of spacer preparation; spacer #3, in which the spacer was prepared as spacer #2 but was stored for two months before starting the experiment; spacer #4, in addition to the gentamycin, other two antibiotics (tobramycin and vancomycin) were added to the bone cement. Gentamycin concentration was documented at seven intervals of time: T0 = 0h, T1 = 1h, T2 = 24h, T3 = 1W, T4 = 2W, T5 = 1M, T6 = 3M and T7 = 6M. The gentamycin elution at each interval of time was evaluated by using a T-student test.


K. Bos A. v. Dorp B. C.P. Koch L. Ringeling E. S. Veltman J. v. Oldenrijk

Aim

The current antibiotic treatment of periprosthetic joint infection (PJI) is optimized by measuring concentrations in plasma. However, it remains unclear whether effective concentrations of the antibiotics are reached at the site of PJI. Nonetheless, adequate target site concentrations are important to achieve effective eradication of the micro-organism. In order to determine the efficacy of cefuroxime and flucloxacillin in synovial fluid, synovial tissue and bone tissue in relation to the minimal inhibitory concentration (MIC) of the pathogen causing the PJI, we perform a pharmacokinetic/pharmacodynamic (PK/PD) study. Therefore, we aimed to develop validated analytical methods for analysis of cefuroxime and flucloxacillin in synovial fluid, synovial tissue and bone tissue.

Method

Blank samples of synovial fluid, synovial tissue and bone tissue were obtained by orthopedic surgeons during surgery. For validation the samples of each matrix were spiked with both cefuroxime and flucloxacillin. Synovial tissue and bone tissue was pulverized with a mikro-dismembrator. Samples were kept frozen at −20°C until analysis. After a sample preparation quantification of cefuroxime and flucloxacillin in each matrix was performed on the ultra-performance convergence chromatography-tandem mass spectrometry (UPC2-MS/MS). Stable-isotope-labeled meropenem-d6 served as internal standard. The linearity, limits of quantification, accuracy and precision and carry-over were determined for all methods separately. The methods were validated according to the European Medicine Agency (EMA) and Food and Drug Administration (FDA) guidelines on bioanalytical method validation.


N. Walter M. Rupp V. Alt

Aim

The aim of the present work was (i) to survey the situation of healthcare regarding the use of antibiotics in orthopaedics and trauma surgery in Germany, (ii) to determine which empiric antibiotic regimens are preferred in the treatment of periprosthethic joint infections (PJI) and (iii) to evaluate the hypothetical antibiotic adequacy of the applied empirical antibiotic therapy regimens based on a patient collective of a German university hospital.

Method

A survey on empirical and prophylactic antibiotic therapy was conducted at German university and occupational health clinics (BG clinics), each in the specialties of orthopedics and trauma surgery. A total of 71 clinics were contacted by email. The questionnaire sent included open-ended questions on systemic antibiotic prophylaxis in primary hip arthroplasty; a distinction was made between hip arthroplasty due to femoral fractures and elective hip arthroplasty. In addition, the empirical antibiotic therapy used in PJIs was surveyed. To determine the success rate of prophylaxis and therapy according to sensitivity to the antibiotics applied, the survey results were compared with previously published data on antimicrobial treatment in n=81 PJI patients treated in our department between 2017 and 2020.


S. L. Pardos L. R. No A. Arderiu M. L. S. Redó D. P. Prieto J. G. Junyent L. P. Verdie A. A. Fabrego N. Prim S. G. Cerrato

Aim

Vancomycin is frequently used for bone and joint infections (BJI) because of the main role of Gram-positive bacteria as potential causal agents. It is crucial to achieve optimal vancomycin plasma concentrations since the first day to maximize treatment clinical and microbiological efficacy. The aim was to describe the patients’ profile that are more likely to achieve an optimal pharmacokinetic/pharmacodynamics (PK/PD) vancomycin target in the first therapeutic drug monitoring (TDM) sample.

Methods

Retrospective study (March 2018-January 2022) in a university hospital including all patients treated with vancomycin for a BJI and undergoing TDM. Initial dose (1g/8-12h) was selected by the responsible clinician. Vancomycin plasma concentrations were obtained pre-dose (Cmin,ss) and 60-minutes after the infusion on day 2 of treatment. Global exposure measured by the area under the curve of plasma concentrations during 24h (AUC024h) was estimated using a bicompartmental PK model.

An AUC024h/CMI=400–600mg*h/L was considered optimal, <400 infratherapeutic and >600 supratherapeutic, based on recent guidelines, and patients were classified into these 3 groups. A value of CMI=1 mg/L was considered, following guidelines recommendations.

Categorial data: percentages and quantitative data as mean (standard deviation).


T. Azamgarhi A. Scobie N. Karunaharan S. O. Mepham D. Mack K. Vekaria K. Crick S. H. Chin S. Warren

Aim

There is a lack of data supporting the use of doxycycline as a single agent after removing infected orthopaedic metalwork. We evaluated the efficacy and safety of doxycycline compared with other single antibiotic regimens used at our specialist orthopaedic hospital.

Methods

A retrospective observational study including all adult patients diagnosed with an orthopaedic metalwork infection due to staphylococci. All patients were managed with the removal of metalwork, and multiple intraoperative samples were sent for culture, followed by the administration of at least four weeks of oral antibiotics. Antibiotic selection was on the recommendation of an infection consultant.

Infection outcome was assessed as the proportion of patients meeting the OVIVA Trial definition of definite failure at follow-up. The probability of definite failure for doxycycline and the alternatives group was estimated using the Kaplan-Meier survival method. All adverse drug reactions (ADR) during treatment were analysed.


N. Müller A. Trampuz M. Gonzalez-Moreno

Aim

The rise of multidrug-resistant bacteria and the decreasing efficacy of antibiotic therapy in successfully treating biofilm-associated infections are prompting the exploration of alternative treatment options. This study investigates the efficacy of different bioactive glass (BAG) formulations - alone or combined with vancomycin - to eradicate biofilm. Further, we study the influence of BAG on pH and osmotic pressure as important factors limiting bacterial growth.

Method

Different BAG-S53P4 formulations were used for this study, including (a) BAG-powder (<45 μm), (b) BAG-granules (500–800 μm), (c) a cone-shaped BAG-scaffold and (d) two kinds of BAG-putty containing granules, with no powder (putty-A) or with additional powder (putty-B), and a synthetic binder. Inert glass beads were included as control. All formulations were tested in a concentration of 1750 g/ml in Müller-Hinton-Broth. Targeted bacteria included methicillin-resistant Staphylococcus aureus (MRSA) and epidermidis (MRSE). Vancomycin was tested at the minimum-inhibitory-concentration for each strain (1 µg/ml for MRSA; 2 μg/ml for MRSE).

To investigate the antibiofilm effect of BAG alone or combined with vancomycin, 3 hour-old MRSA or MRSE biofilms were formed on porous glass beads and exposed to BAG ± vancomycin for 24h, 72h and 168h. After co-incubation, biofilm-beads were deep-washed in phosphate-buffered saline and placed in glass vials containing fresh medium. Recovering biofilm bacteria were detected by measuring growth-related heat production at 37°C for 24h by isothermal microcalorimetry.

Changes in pH and osmotic pressure over time were assessed after co-incubation of each BAG formulation in Müller-Hinton-Broth for 0h, 24h, 72h and 168h.


C. G. Cardona I. Omiste M. C. B. Johnson M. Veloso L. Gómez B. E. Cisneros J. H. N. Camarena D. B. García L. Font-Vizcarra

Aim

Acute post-surgical infection is one of the most serious complications after instrumented thoracolumbar fusion with an incidence of 0.7%-12%. Acute infection can lead to an increase in morbidity, mortality, and economic costs for the healthcare system.

The main objective of our study was to determine the variables associated with a higher risk of acute infection after thoracolumbar instrumentation in our center.

Methods

We conducted an observational case-control study including instrumented fusions of the thoracolumbar spine performed between 2015 and 2021 at our institution. We included patients with thoracolumbar fusions after a fracture or for the treatment of degenerative pathology.

We analyzed demographic variables related to the surgical procedure, the causative microorganism of infection, the outcome of infection treatment, and complications.

We performed a descriptive analysis of all variables and a univariate comparison of cases and controls. The dichotomous variables were compared using the Fisher test, while the quantitative variables were compared using the Student's T-test. A p-value of <0.05 is taken into account to consider the statistical significance. SPSS v25 Windows program was used for statistical analyses.


J. A. Mitterer B. JH. Frank S. Gardete-Hartmann L. F Panzenboek S. Simon P. Krepler J. G. Hofstaetter

Aim

In severe cases of postoperative spinal implant infections (PSII) multiple revision surgeries may be needed. Little is known if changes of the microbiological spectrum and antibiotic resistance pattern occur between revision surgeries. Therefore, the aim of this study was to analyze the microbiological spectrum and antibiotic resistance pattern in patients with multiple revision surgeries for the treatment of PSII. Furthermore, changes of the microbiological spectrum, distribution of mono vs. polymicrobial infections, and changes of the antimicrobial resistance profile in persistent microorganisms were evaluated.

Method

A retrospective analysis of a prospectively maintained single center spine infection database was performed with a minimum follow-up of 3 years. Between 01/2011 and 12/2018, 103 patients underwent 248 revision surgeries for the treatment of PSII. Overall, 20 patients (6 male/14 female) underwent 82 revisions for PSII (median 3; range 2–12). There were 55/82 (67.1%) procedures with a positive microbiological result. Microbiological analysis was performed on tissue and implant sonication fluid. Changes in microbial spectrum and antibiotic resistance pattern between surgeries were evaluated using Chi-Square and Fisher's exact test.


A. Hotchen J. Kendall M. Scarborough M. McNally

Aim

To assess whether recurrence of PJI and osteomyelitis impacts patient-reported quality of life (QoL).

Method

We studied patients receiving surgical treatment for confirmed PJI or osteomyelitis in one of 26 centres in the UK. Patients completed the EQ-5D-3L questionnaire, directly after surgery, at day 14, day 42, day 120 and day 365 after surgery and were assessed for evidence of recurrence.


S. Stevoska F. Himmelbauer J. Stiftinger C. Stadler L. Pisecky T. Gotterbarm A. Klasan

Aim

Antimicrobial resistance (AMR) aggravates an already difficult treatment of periprosthetic joint infections (PJI). The prevalence of drug-resistant pathogens varies across countries and increases over time. Regular monitoring of bacteriological analyses should be performed. Due to many factors influencing the AMR, the correct choice of antimicrobial management remains arguable. The primary purpose of this retrospective study was to identify and compare causative bacteria and to compare the incidence of antibiotic resistance between the septic revision total knee arthroplasty (TKA) and septic revision total hip arthroplasty (THA).

Method

A review of all revision TKAs and revision THAs, undertaken between 2007 and 2020 in a tertiary referral centre, was performed. Included were cases meeting the consensus criteria for PJI, in which an organism has been identified. There were no major differences in tissue sampling between revision TKAs and revision THAs over time.


B. Young M. Dudareva M. Vicentine A. Hotchen M. McNally

Aim

We reviewed a cohort of individuals with recurrent orthopaedic infection to describe the relative rates of microbial persistence vs re-infection at recurrence surgery.

Method

A cohort of 125 individuals with recurrent infection (prosthetic joint infection, fracture-related infection and osteomyelitis) from two centres in the UK between 2007 and 2021. Electronic patient records were reviewed to identify culture results from surgical samples at index surgery and the next operation for recurrent infection. Antibiotic sensitivity results were recorded as sensitive, intermediate or resistant according to contemporary sensitivity testing guidelines.


L. Cecotto K.P.M. van Kessel M.A. Wolfert H.C. Vogely B.C.H. van der Wal H.H. Weinans J.A.G. van Strijp S. Amin Yavari

Aim

In the current study we aim to characterize the use of cationic host defense peptides (HDPs) as alternative antibacterial agents to include into novel antibacterial coatings for orthopedic implants.

Staphyloccous aureus represent one the most challenging cause of infections to treat by traditional antibacterial therapies. Thanks to their lack of microbial resistance described so far, HDPs represent an attractive therapeutic alternative to antibiotics. Furthermore, HDPs have been showed to control infections via a dual function: direct antimicrobial activity and regulation of immune response. However, HDPs functions characterization and comparison is controversial, as changing test conditions or cell type used might yield different effects from the same peptide. Therefore, before moving towards the development of HDP-based coatings, we need to characterize and compare the immunomodulatory and antibacterial functions under the same conditions in vitro of 3 well-known cathelicidins: human LL-37, chicken CATH-2, and bovine-derived IDR-1018.

Method

S. aureus, strain SH1000, was incubated with different concentrations of each HDP and bacterial growth was monitored overnight. Primary human monocytes were isolated from buffy coats using Ficoll-Paque density and CD14 microbeads, and differentiated for 7 days to macrophages. After 24h incubation in presence of LPS and HDPs, macrophages cytokines production was measured by ELISA. Macrophages cultured for 24h in presence of HDPs were infected with serum-opsonized S. aureus. 30 min and 24h after infection, bacterial phagocytosis and intracellular killing by macrophages were measured by flow cytometry and colony forming units (CFU) count respectively.


I. N. M. Santos M. N. L. Kurihara F. F. Santos T. B. Valiatti J. T. P. d. Silva A. C. C. Pignatari M. Salles

Aim

S. aureus and S. epidermidis remain the leading biofilm-forming agents causing orthopedic implant-associated infections (OIAI), but other coagulase-negative Staphylococcus (CoNS) with clinical importance is emerging. Besides, few studies have assessed specific genomic traits associated with patient outcome. This is a preliminary descriptive study of phenotypic and genomic features identified in clinical isolates of S. aureus and CoNS isolates recovered from OIAIs patients that progressed to treatment failure.

Methods

Ten isolates were identified by matrix-time-of-flight laser-assisted desorption mass spectrometry (MALDI-TOF-MS) and tested for antibiotic susceptibility and biofilm formation. Genotypic characteristics, including, MLST (Multi Locus Sequence Typing), SCCmec typing, virulence and resistance genes were assessed by whole-genome sequencing (WGS) that was performed on an Illumina HiSeq 2500 platform. Bioinformatics analyzes were performed using CGE, PATRIC, VFDB, CARD RGI, SnapGene, BLAST, and PubMLST. S. aureus (215, 260 and 371) isolates belonged to CC5 (ST5 and ST105, spa type t002) and carried SCCmec type I (1B), II (2A) and V(5C2), respectively.


M. Dudareva R. Corrigan A. Hotchen R. Muir A. Sattar C. Scarborough M. Kumin B. Atkins M. Scarborough M. McNally G. Collins

Aim

Recurrence of bone and joint infection, despite appropriate therapy, is well recognised and stimulates ongoing interest in identifying host factors that predict infection recurrence. Clinical prediction models exist for those treated with DAIR, but to date no models with a low risk of bias predict orthopaedic infection recurrence for people with surgically excised infection and removed metalwork. The aims of this study were to construct and internally validate a risk prediction model for infection recurrence at 12 months, and to identify factors that predict recurrence. Predictive factors must be easy to check in pre-operative assessment and relevant across patient groups.

Methods

Four prospectively collected datasets including 1173 participants treated in European centres between 2003 and 2021, followed up to 12 months after surgery for orthopaedic infections, were included in logistic regression modelling [1–3]. The definition of infection recurrence was identical and ascertained separately from baseline factors in three contributing cohorts. Eight predictive factors were investigated following a priori sample size calculation: age, gender, BMI, ASA score, the number of prior operations, immunosuppressive medication, glycosylated haemoglobin (HbA1c), and smoking. Missing data, including systematically missing predictors, were imputed using Multiple Imputation by Chained Equations. Weekly alcohol intake was not included in modelling due to low inter-observer reliability (mean reported intake 12 units per week, 95% CI for mean inter-rater error −16.0 to +15.4 units per week).


A. Fuglsang-Madsen N. L. Henriksen L. A. Kvich J. K. M. Birch K. T. Hartmann T. Bjarnsholt T. L. Andresen L. K. Jensen J. R. Henriksen A. E. Hansen

Aim

Several local antibiotic-eluting drug delivery systems have been developed to treat bacterial bone infections. However, available systems have significant shortcomings, including suboptimal drug-release profiles with a burst followed by subtherapeutic release, which may lead to treatment failure and selection for drug resistance.

Here, we present a novel injectable, biocompatible, in situ-forming depot, termed CarboCells, which can be fine-tuned for the desired antibiotic-release profile. The CarboCell technology has flexible injection properties that allow surgeons to accurately place antibiotic-eluting depots within and surrounding infectious sites in soft tissue and bones. The CarboCell technology is furthermore compatible with clinical image-guided injection technologies.

These studies aimed to determine the therapeutic potential of CarboCell formulations for treatment of implant-associated osteomyelitis by mono- and dual antimicrobial therapy.

Methods

The solubility and stability of several antibiotics were determined in various CarboCell formulations, and in vitro drug release was characterized. Lead candidates for antimicrobial therapy were selected using a modified semi-solid biofilm model with 4-day-matured Staphylococcus aureus biofilm (osteomyelitis-isolate, strain S54F9). Efficacy was investigated in a rat implant-associated osteomyelitis model established in the femoral bone by intraosseous implantation of a stainless-steel pin with 4-day-old in vitro-matured S. aureus biofilm. CarboCells were injected subcutaneously at the femur, and antimicrobial efficacy was evaluated 7 days post-implantation. Lead formulations were subsequently tested in a well-established translational implant-associated tibial S. aureus osteomyelitis pig model. Infection was established for 7 days before revision surgery consisting of debridement, washing, implantation of a new stainless-steel pin, and injection of antibiotic-releasing CarboCells into the debrided cavity and in the surrounding bone- and soft-tissue. Seven days post-revision, pigs were euthanized, and samples were collected for microbial and histopathological evaluation.


Full Access
K. Browne C. Luney N. Riley

Aim

There are no definitive criteria for the definition of osteomyelitis in the hand and wrist and published case series are small. It remains a relatively uncommon, but difficult to treat problem. We present a series of 30 cases from 2016 to 2021 from a tertiary referral centre. We propose that the principles of thorough surgical debridement, dead space management, skeletal stabilisation and culture driven antibiotic therapy are the key to management of osteomyelitis in the hand and wrist. In addition, we show how these basic principles can be used for both functional and aesthetic impact for the wrist and digits with illustrated cases.

Methods

We conducted a retrospective chart review over a 6 year period and recorded the site of the infection, the soft tissue and bony management, whether antibiotic eluting bone filler was used, the isolated bacterial species, the number of surgical procedures undertaken to treat the infection and the success rate for clearing the infection.


D. H. Mendelsohn N. Walter T. Niedermair V. Alt C. Brochhausen M. Rupp

Aim

Osteomyelitis is a difficult-to-treat disease with high chronification rates. The surgical amputation of the afflicted limb sometimes remains as the patients’ last resort. Several studies suggest an increase in mitochondrial fission as a possible contributor to the accumulation of intracellular reactive oxygen species and thereby to cell death of infectious bone cells. The aim of this study is to analyze the ultrastructural impact of bacterial infection and its accompanying microenvironmental tissue hypoxia on osteocytic and osteoblastic mitochondria.

Method

19 Human bone tissue samples from patients with osteomyelitis were visualized via light microscopy and transmission electron microscopy. Osteoblasts, osteocytes and their respective mitochondria were histomorphometrically analyzed. The results were compared to the control group of 5 non-infectious human bone tissue samples.


A. Menon V. Agashe C. Rodrigues R. Soman A. Sunavala A. Shetty

Aim

Melioidosis is a significant public health problem in endemic regions such as India. Lack of awareness, predominant empiric antibiotic use reducing culture yields, morphotypic variability of cultures and frequent misidentification by automated blood culture systems, pose myriad challenges in diagnosis and treatment. Through this series, we present our experience of Hematogenous Osteomyelitis with Burkholderia pseudomallei.

Method

This was a single centre, retrospective, observational study performed at a tertiary case hospital in Mumbai, India from June 2011 to June 2021.


A. Leeuwesteijn K. Veerman E. Steggink D. Telgt

Aim

Treatment recommendations for periprosthetic joint infections (PJI) include surgical debridement, antibiotic therapy or staged revision. In surgical related foot and ankle infections (SR-FAI), implant removal will lead to instability. Debridement is difficult because the implant is outside the joint. Recommendations regarding PJI treatment can therefore not be extrapolated to the treatment of SR-FAI.

Method

We searched PubMed for the etiology and treatment of SR-FAI, taken into account the time of occurrence, causative microorganisms and surgical treatment options. We integrated this knowledge into a treatment algorithm for SR-FAI.


Full Access
D. Hulsen C. Arts J. Geurts D. Loeffen C. Mitea

Aim

Magnetic resonance imaging (MRI) and 2-[18F]-fluoro-2-deoxy-D-glucose (18F-FDG) Positron Emission Tomography, paired with Computed Tomography (PET/CT) are two indicated advanced imaging modalities in the complicated diagnostic work-up of osteomyelitis. PET/MRI is a relatively novel hybrid modality with suggested applications in musculoskeletal infection imaging. The goal of this study was to assess the value of hybrid 18F-FDG PET/MRI for chronic osteomyelitis diagnosis and surgical planning.

Method

Five suspected chronic osteomyelitis patients underwent a prospective 18F-FDG single-injection/dual-imaging protocol with hybrid PET/CT and hybrid PET/MR. Diagnosis and relevant clinical features for the surgeon planning treatment were compared. Subsequently, 36 patients with 18F-FDG PET/MRI scans for suspected osteomyelitis were analysed retrospectively. Sensitivity, specificity, and accuracy were determined with the clinical assessment as the ground truth. Standardized uptake values (SUV) were measured and analysed by means of receiver operating characteristics (ROC).


H. Dale A. M. Fenstad G. Hallan S. Overgaard A. B. Pedersen N. P. Hailer J. Kärrholm O. Rolfson A. Eskelinen K. Mäkelä O. Furnes

Aim

Previous publications have suggested that the incidence of revisions due to infection after THA is increasing. We performed updated time-trend analyses of risk and timing of revision due to infection after primary THAs in the Nordic countries during the period 2004–2018.

Methods

569,463 primary THAs reported to the Nordic Arthroplasty Register Association from 2004 through 2018 were studied. We estimated adjusted hazard ratios (aHR) with 95% confidence interval by Cox regression with the first revision due to infection after primary THA as endpoint. The risk of revision was investigated. In addition, we explored changes in the time span from primary THA to revision due to infection.


K. Bos A. Spekenbrink-Spooren M. Reijman S. Bierma-Zeinstra P. Croughs J. v. Oldenrijk

Aim

Aim was to compare revision rates when using single versus dual antibiotic loaded cement (ABLC) in hip fracture arthroplasty and aseptic revision hip or knee arthroplasty using data from the Dutch national joint registry (LROI).

Methods

All primary cemented (hemi-)arthroplasties for acute hip fractures and cemented aseptic hip or knee revision arthroplasties, were incorporated in 3 datasets. All registered implants between 2007 and 2018 were included (minimum 2 years follow-up). Primary end-point was subsequent revision rates for infection and for any reason in the single and dual ABLC groups.

Cumulative crude incidence of revision was calculated using competing risk analysis.


S. Roskar R. Mihalic A. Mihelic R. Trebse

Aim

Debridement, antibiotics and implant retention (DAIR) are considered as an optimal curative treatment option for prosthetic joint infection (PJI) when the biofilm is still immature and radical debridement is achievable. There are two main groups of patients suitable for DAIR. Those with an early acute PJI and patients with acute hematogenous PJI. However, there is also a third group of early PJI resulting from a wound healing problem or leaking hematoma. These may be either high or low grade depending on the microorganisms that infected the artificial joint “per continuitatem”.

Methods

We retrospectively analysed 100 successive DAIR procedures on prosthetic hip and knee joints performed between January 2010 and January 2022, from total of 21000 primary arthroplasties implanted within the same time period. We only included PJI in primary total replacements with no previous surgeries on the affected joint. Patients data (demographics, biochemical, microbiological, histopathological results, and outcomes) were collected from hospital bone and joint infection registry. The aim of surgery was radical debridement and the mobile parts exchange. The standardized antibiotic regime based on antibiofilm antibiotics.


M. Westberg Ø. T. Fagerberg F. Snorrason

Aim

Acute hematogenous periprosthetic joint infection (AHI) is a diagnosis on the rise. The management is challenging and the optimum treatment is not clearly defined. The purpose of this study was to evaluate the characteristics of AHI, and to study risk factors affecting treatment outcome.

Methods

We retrospectively analysed 44 consecutive episodes with AHI in a total hip or knee arthroplasty beween 2013 and 2020 at a single center. AHI was defined as abrupt symptoms of infection ≥ 3 months after implantation in an otherwise well functioning arthroplasty. We used the Delphi criteria to define treatment failure with a minimum of 1-year follow-up.


T. Ferry C. Arvieux E. Stendel C. Nich P. Delobel V. Zeller A. Sotto F. Dauchy C. RONDE-OUSTAU A. Tizon

Aim

To describe the management of PJI due to S. aureus in CRIOAcs in 2019 and to particularly focus on the evaluation of the efficacy of DAIR regarding control of infection and risk factors for failure up to 12 months.

Method

Thirteen CRIOAcs were selected to participate to the study. Data concerning the management of all the PJI in the year 2019 were retrospectively collected and registered in eCRFs. Inclusion criteria were: ≥ 18 years old patients with S. aureus ± other bacteria (in per surgical procedure sample); knee or hip PJI and with clinical signs of infection. Patients treated with bacteriophages were excluded. All eligible patients were notified by an information letter. Patients treated by the DAIR procedure were selected, and rate of control of infection (no inflammatory local signs or no new surgical procedure or no S. aureus in case of puncture) was analyzed using Kaplan Meier method and risk factors for failure at 12 months were assessed using Cox regression model.


A. Fontanellas Fes D. Pérez-Prieto A. Alier L. P. Verdié S. M. Diaz A. P. i. Pol M. L. S. Redó J. Gómez-Junyent P. H. Gomez

Aim

The gold standard treatment for late acute hematogenous (LAH) periprosthetic joint infection (PJI) is surgical debridement, antibiotics and implant retention (DAIR). However, this strategy is still controversial in the case of total knee arthroplasty (TKA) as some studies report a higher failure rate. The aim of the present study is to report the functional outcomes and cure rate of LAH PJI following TKA treated by means of DAIR at a long-term follow-up.

Method

A consecutive prospective cohort consisting of 2,498 TKA procedures was followed for a minimum of 10 years (implanted between 2005 and 2009). The diagnosis of PJI and classification into LAH was done in accordance with the Zimmerli criteria (NEJM 2004). The primary outcome was the failure rate, defined as death before the end of antibiotic treatment, a further surgical intervention for treatment of infection was needed and life-long antibiotic treatment or chronic infection. The Knee Society Score (KSS) was used to evaluate clinical outcomes. Surgical management, antibiotic treatment, the source of infection (primary focus) and the microorganisms isolated were also assessed.


L. Zanna R. Sangaletti M. Akkaya T. Gehrke M. Citak

Aims

Despite numerous studies on periprosthetic joint infections (PJI), there are no robust data on the risk factors and timing of metachronous infections. This study was performed to answer the following questions: 1) Is there any difference of manifestation time of metachronous PJIs between different localizations of multiple artificial joints? 2) Can we identify any specific risk factor for metachronous PJIs for different localizations of multiple artificial joints?

Methods

Between January 2010 and December 2018, 661 patients with more than one prosthetic joint at the time of PJI surgical treatment were recruited. Seventy-one developed metachronous PJI after a mean time interval of 101.4 months (range 37.5 to 161.5 months). The remaining patients were chosen as control group. The diagnosis of the PJI, including the metachronous PJI, was made according to the Muscoloskeletal Infection Society (MSIS) criteria. The metachronous infections were divided in group 1: metachronous infections in the same extremity (e.g. right hip and right knee); group 2: metachronous infections of the other extremity (e.g. right knee and left hip); group 3: metachronous infections of the lower extremity and upper extremity (e.g. right knee and left shoulder).


R. Osinga G. Sapino D. Guillier D. Schaefer M. Clauss P. d. Summa

Aim

In the context of total knee arthroplasty (TKA), trauma with perigenicular fracture fixation or oncological surgical treatment, soft tissue defects can expose critical structures such as the extensor apparatus, the knee joint, bone or implants. This work compares soft tissue reconstruction (STR) between a classical pedicled gastrocnemius (GC) muscle flap and a pedicled chimeric sural artery perforator (SAP) musculocutaneous GC flap in complex orthoplastic scenarios.

Method

A retrospective study was conducted on prospectively maintained databases in three University Hospitals from January 2016 to February 2021 after orthopaedic, traumatological or oncological treatment. All patients with a perigenicular soft tissue defect and implant-associated infection were included undergoing STR either with a pedicled GC flap or with a pedicled chimeric SAP-GC flap. The outcome analysis included successful STR and flap related complications. The surgical timing, preoperative planning and surgical technique are discussed together with the postoperative rehabilitation protocol.


DAIR AND FLAP Pages 75 - 75
Full Access
L. Boadas M. S. Martos M. Ferrer A. Soriano J. C. Martínez

Background

Acute soft tissue defects (wound dehiscence or necrosis) after a total knee arthroplasty (TKA) may be the cause of the devasting complication of deep infection. When a medium (4–6cm) defect is present, in patellar or infra-patellar localization, a medial hemi-gastrocnemius flap is widely used to cover it, because of its low morbidity and high functional results. Normally, this coverage is not associated to a debridement, antibiotics and implant retention surgery (DAIR).

When facing this situation, we should consider associating to the coverage treatment, like muscle flap, a DAIR procedure, in order to treat the possible acute infection, even when the diagnosis of infection is not clear. We could not find any studies comparing the benefice of this association in the same surgical act to isolated treatment of soft tissue defects.

Our hypothesis was that when a TKA surgical wound defect is present, the risk of an acute infection is elevated and the patient would benefit from a muscle flap with DAIR procedure and polyethylene exchange.

Methods

We performed a retrospective study to compare TKA infection clearance in patients with DAIR and flap in the same surgical act against those who received an isolated flap procedure for soft tissue coverage after an acute surgical wound defect. Patients were identified from a prospectively collated TKA database.

Between 2005 and 2021, 19 patients met our inclusion criteria. A medial hemi-gastrocnemius flap was performed in 15 patients (78%).

Healing or TKA infection clearance was defined as the presence of the original prosthesis after soft tissue coverage intervention, no need of DAIR after soft tissue coverage or no suppressive antibiotic treatment.


C. Russell S.T. J. Tsang M. Dudareva H. Simpson R. Sutherland M. McNally

Aim

Pelvic osteomyelitis following pressure ulceration results in substantial patient morbidity. Previous studies have reported a heterogenous approach to diagnosis and medical management by physicians, suggesting equipoise on key clinical questions. This study hypothesised that the same equipoise exists amongst Orthopaedic surgeons.

Method

An 18-question multiple-choice questionnaire was designed through an iterative feedback process until the final version was agreed by all authors. Likert-type scale responses were used with graded responses (e.g., never/fewer than half of patients/around half of patients/more than half of patients/every patient). The online survey was sent to members of the Musculoskeletal Infection Society (MSIS), the European Bone and Joint Infection Society (EBJIS), and the ESCMID Study Group for Implant-Associated Infections (ESGIAI). No incentive for participation was provided.


J. Schwarze M. Daweke G. Gosheger B. Moellenbeck T. Ackmann J. Puetzler C. Theil

Aim

Repeat revision surgery of total hip or knee replacement may lead to massive bone loss of the femur. If these defects exceed a critical amount a stable fixation of a proximal or distal femur replacement may not be possible. In these extraordinary cases a total femur replacement (TFR) may be used as an option for limb salvage. In this retrospective study we examined complications, revision free survival (RFS), amputation free survival (AFS) and risk factors for decreased RFS and AFS following a TRF in cases of revision arthroplasty with a special focus on periprosthetic joint infection (PJI).

Method

We included all implantations of a TFR in revision surgery from 2006–2018. Patients with a primary implantation of a TFR for oncological indications were not included. Complications were classified using the Henderson Classification. Primary endpoints were revision of the TFR or disarticulation of the hip. The minimum follow up was 24 month. RFS and AFS were analyzed using Kaplan-Meier method, patients´ medical history was analyzed for possible risk factors for decreased RFS and AFS.


G. Cacciola A. Bruschetta F. D. Meo P. Cavaliere

Aim

The primary endpoint of this study is to characterize the progression of bone defects at the femoral and tibial side in patients who sustained PJI of the knee that underwent two-stage revision with spacer implantation. In addition, we want to analyze the differences between functional moulded and hand-made spacers.

Methods

A retrospective analysis of patients that underwent two-stage revision due to PJI of the knee between January 2014 and December 2021 at our institution. Diagnosis of infection was based on the criteria of the Muscoloskeletal Infection Society. The bone defect evaluation was performed intraoperatively based on the AORI classification. The basal evaluation was performed at the time the resection arthroplasty and spacer implantation surgery. The final evaluation was performed at the second-stage surgery, at the time of spacer removal and revision implant positioning. The differences between groups were characterized by using T-test student for continuous variables, and by using chi-square for categorical variables. A p-value < 0.05 was defined as significant.


M. Bernaus Y. L. Cubillos S. Soto A. Bermúdez J. A. Calero D. Torres M. Veloso L. Font-Vizcarra

Aim

To evaluate the efficiency of pulse lavage combined with electrical fields to remove biofilm from a metallic surface.

Method

Using a 12-well culture plate designed for the application of electrical fields, strains of S. epidermidis were incubated at each well for 24 hours at 37ºC. After incubation, supernatant culture medium was removed, and each well was filled with 3ml of normal saline. Six different models were compared: a) control, b) low-pressure pulse lavage, c) high-pressure pulse lavage, d) pulsed electrical fields, e) low-pressure pulse lavage in combination with pulsed electrical fields, and f) high-pressure pulse lavage in combination with pulsed electrical fields. In all cases, exposure time was set to 25 seconds. In the electrical field models, 50 pulses were applied.

After exposure, each bottom electrode was scraped carefully to release adhered bacteria. Subsequently, different dilutions of biofilm removed were spread onto Müller Hinton agar plates and incubated for 24h at 37 ºC, and colony-forming units (CFU) per milliliters were counted. Bacterial counts were then compared to the control model.


P. Morovic S. Karbysheva S. Meller S. Kirschbaum C. Perka A. Conen A. Trampuz

Aim

Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA.

Method

Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity.


M. A. Hvistendahl M. Bue P. Hanberg A. E. Kaspersen A. V. Schmedes M. Stilling K. Høy

Background

Surgical site infection following spine surgery is associated with increased morbidity, mortality and increased cost for the health care system. The reported pooled incidence is 3%. Perioperative antibiotic prophylaxis is a key factor in lowering the risk of acquiring an infection. Previous studies have assessed perioperative cefuroxime concentrations in the anterior column of the cervical spine with an anterior surgical approach. However, the majority of surgeries are performed in the posterior column and often involve the lumbar spine. Accordingly, the objective was to compare the perioperative tissue concentrations of cefuroxime in the anterior and posterior column of the same lumbar vertebra using microdialysis in an experimental porcine model.

Method

The lumbar vertebral column was exposed in 8 female pigs. Microdialysis catheters were placed for sampling in the anterior column (vertebral body) and posterior column (posterior arch) within the same vertebra (L5). Cefuroxime (1.5 g) was administered intravenously over 10 min. Microdialysates and plasma samples were continuously obtained over 8 hours. Cefuroxime concentrations were quantified by Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry. Microdialysis is a catheter-based pharmacokinetic tool, that allows dynamic sampling of unbound and pharmacologic active fraction of drugs e.g., cefuroxime. The primary endpoint was the time with cefuroxime above the clinical breakpoint minimal inhibitory concentration (T>MIC) for Staphylococcus aureus of 4 µg/mL as this has been suggested as the best predictor of efficacy for cefuroxime. The secondary endpoint was tissue penetration (AUCtissue/AUCplasma).


H. Scheper R. Mahdad B. Elzer C. Löwik W. Zijlstra T. Gosens J.C.T. van der Lugt R. van der Wal R.W. Poolman M. Somford P. Jutte K. Bos C. Kooijman H. Maree R. Nelissen Leo G. Visser M. G.J. De Boer

Background

The duration and extent of postoperative wound leakage after joint arthroplasty in patients with or without a complicated course, like a prosthetic joint infection (PJI), is currently unknown. Adequate differentiation between normal postoperative wound leakage and wound leakage due to a postoperative PJI is important and prevents unnecessary surgical procedures. We investigated the association between postoperative wound leakage and development of PJI in patients who used a previously developed mobile wound care app.

Methods

A multicenter, prospective cohort study with patients aged 18 years or older after primary implantation or revision of a total joint arthroplasty. During 30 post-operative days after arthroplasty, patients recorded their wound status in the woundcare app. An algorithm calculated a daily score from imputed data. If the daily score exceeded a predefined threshold, the patients received an alert that advised them to contact their physician.


S. Browning L. Manning S. Metcalf D. L. Paterson O. Robinson B. Clark J. S. Davis

Aim

Culture negative (CN) prosthetic joint infections (PJI) account for approximately 10% of all PJIs and present significant challenges for clinicians. We aimed to explore the significance of CN PJI within a large prospective cohort study, and to compare their characteristics and outcomes with culture positive cases.

Methods

The Prosthetic joint Infection in Australia and New Zealand Observational (PIANO) study is a prospective, binational, multicentre observational cohort study conducted at 27 hospitals between July 2014 and December 2017. We compared baseline characteristics and outcomes of all patients with culture negative (CN) prosthetic joint infection (PJI) from the PIANO cohort with culture positive (CP) cases. “Treatment success” was defined as absence of clinical or microbiological signs of infection, no need for ongoing antibiotics, and no need for revision or resection arthroplasty since the end of the initial treatment. We also describe PJI diagnostic criteria in the CN cohort and apply internationally recognised PJI diagnostic guidelines.


J. Sliepen R. Corrigan M. Dudareva M. Wouthuyzen-Bakker R. Rentenaar B. Atkins F. Hietbrink G. Govaert M. McNally F. Ijpma

Background

Fracture-related infection (FRI) is treated by adequate debridement, lavage, fracture stabilization (if indicated), adequate soft tissue coverage and systemic antimicrobial therapy. Additional administration of local antibiotics (LA), placed directly in the surgical field, is thought to be beneficial for successful eradication of infection.

Aims

1) To evaluate the effect of local antibiotics on outcome in patients with FRI. 2) To evaluate whether bacterial resistance to the implanted local antibiotics influences its efficacy.


G. Mannala M. Rupp V. Alt

Aim

Fungal periprosthetic joint infections are difficult to treat and often associated with a limited outcome for patients. Candida species account for approximately 90% of all fungal infections. In vivo biofilm models play major role to study biofilm development, morphology, and regulatory molecules for bacteria. However, in vivo modeling of biofilm-associated fungi models are very rare. Furthermore, due to ethical restrictions, mammalian models are replaced with other alternative models in basic research. Recently, we have developed insect infection model G. mellonella larvae to study implant associated biofilm infections with bacteria. This model organism was not used for fungi biofilm infection yet. Thus, we aimed to establish G. mellonella as in vivo model to study fungal implant infections using Candida albicans as model organism and to test anti-fungal medication.

Method

Titanium and Stainless steel K-wires were cut into small pieces with size of 4mm. For the infection process, implants were pre-incubated in specified fungal growth culture Candida albicans at 1×107 CFU/ml for 30 min at 150 rpm shaking conditions. Later, these implants were washed with 10ml PBS and implanted in the larvae as mentioned. To analyze the susceptibility of the implant-associated fungal infections towards anti fungal compounds, the larvae were treated with amphotericin B, fluconazole and voriconazole after 24h of implantation. The effect of anti-fungal compounds was measured in terms of survival observation for 5 days and fungal load in larvae on 2nd day. To reveal the fungal biofilm formation on implant, the implants were removed on day 3 and processed for SEM analysis.


M. McNally J. Ferguson M. Scarborough A. Ramsden D. Stubbs B. Atkins

Aim

Excision of chronic osteomyelitis (cOM) creates a dead space which must be managed to avoid early recurrence of infection. Systemic antimicrobials cannot penetrate this space in high concentration so local therapy has become an attractive adjunct to surgery. This study presents the mid- long-term results of local therapy with gentamicin in a bioabsorbable ceramic carrier.

Method

A prospective series of 100 patients with Cierny & Mader Types III and IV cOM, affecting 105 bones, were treated with a single stage procedure, including debridement, deep tissue sampling, local and systemic antimicrobials, stabilization and immediate skin closure. cOM was confirmed with strict diagnostic criteria. Patients were followed up for a mean of 6.05 years (range 4.2–8.4 years).


J. Puetzler J. Hasselmann G. Gosheger S. Niemann M. Fobker J. Hillebrand J. Schwarze C. Theil M. Schulze

Aim

A novel anti-infective biopolymer implant coating was developed to prevent bacterial biofilm formation and allow on-demand burst release of anti-infective silver (Ag) into the surrounding of the implant at any time after surgery via focused high-energy extracorporeal shock waves (fhESW).

Method

A semi-crystalline Poly-L-lactic acid (PLLA) was loaded with homogeneously dissolved silver (Ag) applied onto Ti6Al4V discs. A fibroblast WST-1 assay was performed to ensure adequate biocompatibility of the Ag concentration at 6%. The prevention of early biofilm formation was investigated in a biofilm model with Staphylococcus epidermidis RP62A after incubation for 24 hours via quantitative bacteriology.

In addition, the effect of released Ag after fhESW (Storz DUOLITH SD1: 4000 impulses, 1,24 mJ/mm2, 3Hz, 162J) was assessed via optical density of bacterial cultures (Escherichia coli TG1, Staphylococcus epidermidis RP62A, Staphylococcus aureus 6850) and compared to an established electroplated silver coating. The amount of released Ag after the application of different intensities of fhESW was measured and compared to a control group without fhESW via graphite furnace atomic absorption spectrometry (GF-AAS), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS).


E. Steggink A. Leeuwesteijn D. Telgt K. Veerman

Aim

Failed consolidation (nonunion) after foot and ankle arthrodesis is a major complication, which can lead to additional revision arthrodesis with increased risk of morbidity. Multiple factors can contribute to developing a nonunion, including a low-grade infection. The aim of this study was to investigate the rate of unsuspected low-grade infection in revision arthrodesis for nonunions after foot and ankle arthrodesis. We also analyzed the outcome of unsuspected low-grade infections.

Method

We conducted a retrospective study in The Sint Maartenskliniek, The Netherlands. All patients who underwent revision arthrodesis for assumed aseptic nonunion after foot and ankle arthrodesis between January 2020 and July 2021 were included. Patients were excluded if <5 tissue samples were obtained during revision arthrodesis or if they were treated for infection after the index arthrodesis. For the included patients, at least 5 tissue samples for culture were taken during the revision arthrodesis. The causative microorganisms, antibiotic susceptibility and treatment were assessed. An unsuspected infection was defined as ≥2 positive cultures with phenotypical identical microorganisms. Success was defined as union on imaging during clinical follow-up, without signs of persistent infection after finishing the antibiotic treatment.


A. Alier B. Gasol D. Pérez-Prieto F. Santana C. Torrens

Aim

A significant number of patients undergoing shoulder arthroplasty surgery have C acnes contamination at the end of the primary surgery. The objective of this study is to determine whether patients with C acnes contamination at the end of their primary shoulder surgery have a worse prognosis than those who end up without C. acnes contamination.

Method

Prospective study including all patients who underwent a reverse shoulder prosthesis from January 2015 to December 2018. In all of them, 5 to 12 cultures were performed during primary surgery. The patients underwent surgery for shoulder arthritis secondary to rotator cuff tears, acute fracture of the proximal humerus, and sequelae of fracture of the proximal humerus. Exclusion criteria included the existence of previous surgeries on the affected shoulder, the presence of signs of infection, having received infiltrations and / or complementary invasive examinations (Arthro-MRI and Arthro-CT). Follow-up from 2 to 5 years. Functional assessment according to the Constant Functional Scale. All complications were also recorded.


L. K. Jensen H. E. Jensen H. Gottlieb

Aim

To describe the histopathology of the first and last debrided bone tissue in chronic osteomyelitis and answer the following research question; is the last debrided bone tissue viable and without signs of inflammation?

Method

In total, 15 patients with chronic osteomyelitis were allocated to surgical treatment using a one stage protocol including extensive debridement. Suspected infected bone tissue eradicated early in the debridement procedure was collected as a clearly infected sample (S1). Likewise, the last eradicated bone tissue was collected as a suspected non-infected sample (S2), representing the status of the bone void. In all cases, the surgeon debrided the bone until visual confirmation of healthy bleeding bone. The samples were processed for histology, i.e. decalcification and paraffin embedding, followed by cutting and staining with Haematoxylin and Eosin. Immunohistochemistry with MAC-387 antibodies towards the calprotectin of neutrophil granulocytes (NGs) was also performed and used for estimation of a neutrophil granulocyte (NG) score (0, 1, 2 or 3), by the method described for fracture related infections (1).