header advert
Results 1 - 67 of 67
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 48 - 48
1 Mar 2017
Tei K Minoda M Shimizu T Matsuda S Matsumoto T Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed and widely used. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femoro-tibial joint as well as posterior-stabilized (PS) polyethylene insert, even if PCL is sacrificed after TKA. The purpose of this study is an investigation of in vivo kinematics of femoro-tibial joint with use of CS polyethylene insert before and after PCL resction using computer assisted navigation system and tensor device intra-operatively in TKA.

Materials and Methods

Sixty-one consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. During surgery, using a tensor device, after bony cut of femur and tibia, joint gaps were assessed in 0 and 90 degrees in flexion. Then, CS polyethylene tibial trial insert were inserted after trial implantation of femoral and tibial components, before and after resection of PCL, respectively. The kinematic parameters of the soft-tissue balance, and amount of coronal and sagittal relative movement between femur and tibia were obtained by interpreting kinematics, which display tables throughout the range of motion (ROM) in the navigation system. In each ROM (30, 45, 60, 90, max degrees), the data were analyzed with a ANOVA test, and mean values were compared by the multiple comparison test (Turkey HSD test) (p< 0.05).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 25 - 25
1 Feb 2017
Inokuchi T Ishida K Shibanuma N Matsumoto T Takayama K Toda A Kodato K Kuroda R Kurosaka M
Full Access

Introduction

Range of motion (ROM) is one of the important factor for better functional outcome after total knee arthroplasty (TKA). In posterior cruciate ligament (PCL) retaining (CR) TKA, adequate PCL function is suggested to be important for better kinematics and ROM. However, intraoperative assessment of PCL function is relatively subjective, thus more objective evaluation is required to improve the functional outcomes after TKA. In clinical practice, tibial posterior sagging sign is well known to indicate PCL deficiency. Hence, we hypothesized that intraoperative femorotibial antero-posterior (AP) changes at 90° of flexion indirectly reflected the PCL function and associated with postoperative maximum flexion angles in CR TKA. The purpose of this study was to investigate the correlation between intraoperative femorotibial AP changes at 90° of flexion and postoperative maximum flexion range in navigated CR TKA.

Methods

Between March 2014 and March 2015, forty patients with varus osteoarthritis underwent primary TKA. All of the cases were using same types of implant (Triathlon; Stryker Orthopedics, Mahwah, NJ, USA), with an image-free navigation system (Stryker 4.0 image-free computer navigation system; Stryker). PCL was retained and cruciate substituting (CS) inserts were used in all cases. The mean age at the time of surgery was 71.7 ± 6.8 years old (ranging: 62 – 85). The mean follow-up was 10.9 ± 6.4 months. After minimum release of medial and lateral soft tissue, resection of anterior cruciate ligaments, and protection of PCL, registration and kinematic measurements were performed prior to bone resection. The kinematic measurements were performed again after implantation. The center of proximal tibial and distal femur were defined during registration. The point of proximal tibia was projected to the mechanical axis of femur and the distance between the projected point and the distal femur at 90° of flexion were measured and defined as femorotibial AP position. Distal relative to the center of distal femur indicates as minus, and proximal relative to the point indicates as plus. The correlation between the intraoperative changes of AP position and postoperative maximum flexion angles were investigated.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 29 - 29
1 Feb 2017
Ishida K Shibanuma N Toda A Kodato K Inokuchi T Matsumoto T Takayama K Kuroda R Kurosaka M
Full Access

PURPOSE

Total knee arthroplasty (TKA) is a successful technique for treating painful osteoarthritic knees. However, the patients' satisfaction is not still comparable with total hip arthroplasty. Basically, the conditions with operated joints were anterior cruciate ligament (ACL) deficient knees, thus, the abnormal kinematics is one of the main reason for the patients' incomplete satisfaction. Bi-cruciate stabilized (BCS) TKA was established to reproduce both ACL and posterior cruciate ligament (PCL) function and expected to improve the abnormal kinematics. However, there were few reports to evaluate intraoperative kinematics in BCS TKA using navigation system. Hence, the aim in this study is to reveal the intraoperative kinematics in BCS TKA and compare the kinematics with conventional posterior stabilized (PS) TKA.

Materials and Methods

Twenty five consecutive subjects (24 women, 1 men; average age, 77 years; age range, 58–85 years) with varus osteoarthritis undergoing navigated BCS TKA (Journey II, Smith&Nephew) were enrolled in this study. An image-free navigation system (Stryker 4.0 image-free computer navigation system; Stryker) was used for the operation. Registration was performed after minimum medial soft tissue release, ACL and PCL resection, and osteophyte removal. Then, kinematics including tibiofemoral rotational angles from maximum extension to maximum flexion were recorded. The measurements were performed again after implantation. We compared the kinematics with the kinematics of paired matched fifty subjects who underwent conventional posterior stabilized (PS) TKA (25 subjects with Triathlon, Stryker; 25 subjects with PERSONA, ZimmerBiomet) using navigation statistically.


Bone & Joint Research
Vol. 5, Issue 12 | Pages 602 - 609
1 Dec 2016
Muto T Kokubu T Mifune Y Inui A Sakata R Harada Y Takase F Kurosaka M

Objectives

Triamcinolone acetonide (TA) is widely used for the treatment of rotator cuff injury because of its anti-inflammatory properties. However, TA can also produce deleterious effects such as tendon degeneration or rupture. These harmful effects could be prevented by the addition of platelet-rich plasma (PRP), however, the anti-inflammatory and anti-degenerative effects of the combined use of TA and PRP have not yet been made clear. The objective of this study was to determine how the combination of TA and PRP might influence the inflammation and degeneration of the rotator cuff by examining rotator cuff-derived cells induced by interleukin (IL)-1ß.

Methods

Rotator cuff-derived cells were seeded under inflammatory stimulation conditions (with serum-free medium with 1 ng/ml IL-1ß for three hours), and then cultured in different media: serum-free (control group), serum-free + TA (0.1mg/ml) (TA group), serum-free + 10% PRP (PRP group), and serum-free + TA (0.1mg/ml) + 10% PRP (TA+PRP group). Cell morphology, cell viability, and expression of inflammatory and degenerative mediators were assessed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 65 - 65
1 May 2016
Takayama K Matsumoto T Muratsu H Ishida K Kuroda R Kurosaka M
Full Access

The influence of amount of tibial posterior slope changes on joint gap and postoperative range of motion was investigated in 35 patients undergoing unicompartmental knee arthroplasty (UKA). Component gap between the medial tibial osteotomy surface and the femoral trial prosthesis was measured throughout the range of motion using a tensor. The mean tibial posterior slope decreased from 10.2 to 7.3 degrees. Increased tibial slope change was positively correlated with component gap differences of 90° −10°, 120° −10°, and 135° −10° and negatively correlated with postoperative extension angle. Increasing tibial slope should be avoided to achieve full extension angle after UKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 52 - 52
1 May 2016
Ishida K Shibanuma N Toda A Matsumoto T Takayama K Sasaki H Oka S Kodato K Kuroda R Kurosaka M
Full Access

Purpose

To investigate the tibiofemoral rotational profiles during surgery in navigated posterior-stabilized (PS) total knee arthroplasty (TKA) and investigated the effect on postoperative maximum flexion angles.

Materials and Methods

At first, twenty-five consecutive subjects (24 women and 1 man; age: mean, 77 years; range, 58–85 years) with varus osteoarthritis treated with navigated PS TKA (Triathlon, Stryker, Mahwah, NJ) were enrolled in this study. Kinematic parameters, including the tibiofemoral rotational angles from maximum extension to maximum flexion, were recorded thrice before and after PCL resections, and after implantation. The effect of PCL resection and component implantation on tibiofemoral rotational kinematics was statistically evaluated. Then, the effect of tibiofemoral rotational alignment changes on the postoperative maximum angles were retrospectively examined with 96 subjects (84 women, 12 men; average age, 76 years; age range, 56–88 years) who underwent primary TKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 24 - 24
1 May 2016
Matsumoto T Shibanuma N Takayama K Sasaki H Ishida K Nakano N Matsushita T Kuroda R Kurosaka M
Full Access

The influence of soft tissue balance in mobile-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) on the patellofemoral (PF) joint was investigated in thirty varus-type osteoarthritis patients. Intraoperative soft tissue balance including joint component gap and varus/valgus ligament balance and the medial/lateral patellar pressure were measured throughout the range of motion after the femoral component placement and the PF joint repair. The lateral patellar pressure, which was significantly higher than the medial side in the flexion arc, showed inverse correlation with the lateral laxity at 60° and 90° of flexion. The lateral patellar pressure at 120° and 135° of flexion also inversely correlated with the postoperative flexion angle. Surgeons should take medial and lateral laxity into account when considering PF joint kinematics influencing postoperative flexion angle in PS TKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 76 - 76
1 May 2016
Tei K Kihara S Shimizu T Matsumoto T Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femolo-tibial joint as well as posterior-stabilized (PS) polyethylene insert, even if PCL is sacrificed after TKA. The purpose of this study is an investigation of in vivo kinematics of femolo-tibial joint with use of CS polyethylene insert before and after PCL resction using computer assisted navigation system intra-operatively in TKA.

Materials and Methods

Twenty-four consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. In all patients, difference between extension and flexion gap was under 3mm after bony cut of femur and tibia. During surgery, CS polyethylene tibial trial insert were inserted after trial implantation of femoral and tibial components, before and after resection of PCL, respectively. The kinematic parameters of the soft-tissue balance, and amount of coronal (valgus/varus), sagittal (anterior/posterior) and rotational relative movement between femur and tibia were obtained by interpreting kinematics, which display tables throughout the range of motion (ROM) (Figure1). During record of kinematics, the surgeon gently lifted the experimental thigh three times, flexing the hip and knee. In each ROM (30, 45, 60, 90, max degrees), the data were analyzed with paired t-test, and an ANOVA test, and mean values were compared by the multiple comparison test (Turkey HSD test) (p < 0.05).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 138 - 138
1 May 2016
Yamaura K Muratsu H Tsubosaka M Annziki K Kudo K Minamino S Oshima T Matsumoto T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction

As the aging society progresses rapidly, the number of patients underwent total knee arthroplasty (TKA) is increasing especially for the elderly population. In Japan, the average age for TKA is around 75 years old. Japanese Orthopaedic Association indicated a new clinical entity of musculoskeletal ambulation disability symptom complex (MADS) to define the higher risk of fall and ambulatory disability in the elderly population in 2006. The diagnosing criteria for MADS consists of 2 simple performance tests. 3m timed up and go test (TUG) evaluates ambulatory function, and one leg standing time (ST) assesses balancing ability.

Objective

In this study, we analyzed the effect of TKA on the ambulatory function by quantitative measurement using 2 simple performances test: TUG and ST.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 68 - 68
1 May 2016
Muratsu H Takemori T Matsumoto T Annziki K Kudo K Yamaura K Minamino S Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction

To achieve well aligned and balanced knee is essential for the post-operative outcome in total knee arthroplasty (TKA). Gap balancing technique can adjust the bone cut depending on the soft tissue balance in addition to soft tissue releases. Therefore, gap balancing technique would be more advantageous in soft tissue balance comparing to measured resection technique (MRT) in which soft tissue balancing relayed on soft tissue releases alone. Nevertheless, the influence of surgical technique on the post-operative knee stability has not been fully investigated.

Objective

We introduced a new surgical technique (medial gap technique: MGT) according to modified gap technique regarding medial knee stability as important. The intra-operative soft tissue balance and post-operative knee stability were compared between MGT and MRT in posterior-stabilized (PS) TKA for varus type osteoarthritic knees.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 32 - 32
1 May 2016
Hashimoto S Hayashi S Kanzaki N Chinzei N Kuroda R Kurosaka M
Full Access

Introduction

The advance of surgical technique and implant design have led to improvement in total hip arthroplasty (THA), and short stem THA is now gaining number as a treatment option for younger patients to preserve bone in the proximal femur for a future revision. The SMF stem is shorter stem, and requires a slightly higher neck resection and implanted in slight varus to contact at lateral cortex. Developmental dysplasia of the hip (DDH) is the most common cause to hip osteoarthritis (OA) in Japan, and the morphology of the dysplastic femur is narrow canal and increased anteversion. Thus, the purpose of this study is to evaluate the SMF stem design can fit for Japanese patients, using CT based 3-D template planning.

Methods

We evaluated 30 patients who required THA in our institution. Inclusion criteria are hip OA, but cases with post-trauma, post-osteotomy, and any other hip disease in childhood are excluded. Patients were selected with their femoral anteversion, based on the dispersion of anteversion in dysplastic hip population, which was reported by Noble and collegues in 2003. Preoperative planning with ZedHip software (Lexi, Japan) was performed by established protocol. The center of socket was placed at 15mm proximal from teardrop and medialized to primary acetabulum, with 40° of radiographic inclination and 20° of anteversion. Neck resection of femur was 20mm proximal from the top of smaller trochanter, and stem was placed with lateral fit at distal and medial fit at calcar with appropriate size. Stem offset was selected by leg extension and balanced shenton line. Finally, ROM simulation was performed and the socket anteversion was arranged to achieve the optimal ROM. And then, SMF stem alignment and appropriate fitting was evaluated in Japanese OA cases.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 34 - 34
1 May 2016
Hayashi S Hashimoto S Kanzaki N Kuroda R Kurosaka M
Full Access

Purpose

The purpose of this study was to evaluate periprosthetic bone mineral density (BMD) changes around a cementless short tapered-wedge stem and determine correlations between BMD changes and various clinical factors, including daily activity, after total hip arthroplasty (THA) with a short tapered-wedge stem.

Methods

The study included 65 patients (65 joints) who underwent THA with a TriLock stem. At baseline, and 6, 12, and 24 months postoperatively, BMDs of the seven Gruen zones were evaluated using dual-energy X-ray absorptiometry. Correlations were determined between BMD changes and clinical factors, including the Harris hip score, body mass index, University of California at Los Angeles (UCLA) activity rating score, age at surgery, and initial lumbar BMD.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 74 - 74
1 May 2016
Nakano N Matsumoto T Muratsu H Takayama K Kuroda R Kurosaka M
Full Access

Introduction / Purpose

Many factors can influence postoperative knee flexion angle after total knee arthroplasty (TKA), and range of flexion is one of the most important clinical outcomes. Although many studies have reported that postoperative knee flexion is influenced by preoperative clinical conditions, the factors which affect postoperative knee flexion angle have not been fully elucidated. As appropriate soft-tissue balancing as well as accurate bony cuts and implantation has traditionally been the focus of TKA success, in this study, we tried to investigate the influence of intraoperative soft-tissue balance on postoperative knee flexion angle after cruciate-retaining (CR) TKA using a navigation system and offset-type tensor.

Methods

We retrospectively analyzed 55 patients (43 women, 12 men) with osteoarthritis who underwent TKA using the same mobile-bearing CR-type implant (e.motion; B. Braun Aesculap, Germany). The mean age at the time of surgery was 74.2 (SD 7.3) years. The exclusion criteria for this study included valgus deformity, severe bony defect requiring bone graft or augmentation, revision TKA, active knee joint infection, and bilateral TKA. Intraoperative soft-tissue balance parameters such as varus ligament balance and joint component gap were measured in the navigation system (Orthopilot 4.2; B. Braun Aesculap) while applying 40-lb joint distraction force at 0°, 10°, 30°, 60°, 90°, and 120° of knee flexion using an offset-type tensor with the patella reduced. Varus ligament balance was defined as the angle (degree, positive value in varus imbalance) between the seesaw and platform plates of the tensor that was obtained from the values displayed by the navigation system. To determine clinical outcome, we measured knee flexion angle using a goniometer with the patient in the supine position before and 2 years after surgery. Correlations between the soft-tissue parameters and postoperative knee flexion angle were analyzed using simple linear regression models. Pre- and postoperative knee flexion angle were also analyzed in the same manner.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 78 - 78
1 May 2016
Chinzei N Hayashi S Kanzaki N Hashimoto S Kihara S Haneda M Takeuchi K Kuroda R Kurosaka M
Full Access

Introduction

Failure of acetabular components has been reported to lead to large bone defects, which determine outcome and management after revision total hip arthroplasty (THA). Although Kerboull-type (KT) plate (KYOCERA Medical Corporation, Kyoto, Japan) has been used for compensating large bone loss, few studies have identified the critical risk factors for failure of revision THA using a KT plate. Therefore, the aim of this study is to evaluate the relationship between survival rates for radiological loosening and the results according to bone defect or type of graft.

Patients and methods

This study included patients underwent revision THA for aseptic loosening using cemented acetabular components with a KT plate between 2000 and 2012. Bone defects were filled with beta Tricalcium phosphate (TCP) granules between 2000 and 2003 and with Hydroxyapatite (HA) block between 2003 and 2009. Since 2009, we have used femoral head balk allografts. Hip function was evaluated by using the Japanese Orthopaedic Association (JOA) score and University of California, Los Angeles (UCLA) activity. Acetabular defects were classified according to the American Academy of Orthopedic Surgeons (AAOS) classification. The postoperative and final follow-up radiographs were compared to assess migration of the implant. Kaplan–Meier method for cumulative probabilities of radiographic failure rate, and the comparison of survivorship curves for various subgroups using the log-rank test were also evaluated. Logistic regression was performed to examine the association of such clinical factors as the age at the time of operation, body mass index, JOA score, UCLA activity score, and AAOS classification with radiographic failure. Odds ratios (ORs) and 95% CIs were calculated. Multivariate analysis was performed to adjust for potential confounders by clinical factors. Values of p < 0.05 were considered significant.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 50 - 50
1 Jan 2016
Takemori T Muratsu H Takeoka Y Matsumoto T Takashima Y Tsubosaka M Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective

The goal of total knee arthroplasty (TKA) is to achieve a stable and well-aligned tibiofemoral and patello-femoral (PF) joint, aiming at long-term clinical patient satisfaction. The surgical principles of both cruciate retaining (CR) and posterior stabilized (PS) TKA are accurate osteotomy and proper soft tissue balancing. We have developed an offset-type tensor, and measured intra-operative soft tissue balance under more physiological joint conditions with femoral component in place and reduced PF joint.

In this study, we measured intra-operative soft tissue balance and assessed the post-operative knee joint stability quantitatively at one month, six months and one year after surgery, and compared these parameters between CR and PS TKAs.

Material and Method

Sixty patients with varus osteoarthritis of the knee underwent TKAs (30 CR TKAs: CR and 30 PS TKAs: PS). Mean varus deformity in standing position was 11.1 degrees in CR, and 12.6 degrees in PS. All TKAs were performed by a single surgeon with measured resection technique. The external rotation of posterior femoral condyle osteotomy was performed according to surgical epicondylar axis in pre-operative CT. We measured intra-operative soft tissue balance using an offset-type tensor with 40 lbs of joint distraction force at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. The joint component gap (mm) and varus angle (degrees) were measured at each flexion angles.

One month, six months and one year after surgery, we evaluated the knee stability at extension by varus and valgus stress radiography using Telos (10kg) and at flexion by epicondylar view with 1.5kg weight at the ankle. We measured joint separation distance at medial as medial joint looseness (MJL) and at lateral as lateral joint looseness (LJL). Intra-operative measurements and post-operative joint stabilities were compared between CR and PS using unpaired t-test. The change of joint looseness in each group was analyzed using repeated measures ANOVA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 62 - 62
1 Jan 2016
Ishida K Sasaki H Toda A Kodato K Matsumoto T Takayam K Kuroda R Kurosaka M Shibanuma N
Full Access

Background

Data on varus-valgus and rotational profiles can be obtained during navigated total knee arthroplasty (TKA). Such intraoperative kinematic data might provide instructive clinical information for refinement of surgical techniques, as well as information on the anticipated postoperative clinical outcomes. However, few studies have compared intraoperative kinematics and pre- and postoperative clinical outcomes; therefore, the clinical implications of intraoperative kinematics remain unclear.

In clinical practice, subjects with better femorotibial rotation in the flexed position often achieve favorable postoperative range of motion (ROM); however, no objective data have been reported to prove this clinical impression. Hence, the present study aimed to investigate the correlation between intraoperative rotation and pre- and postoperative flexion angles.

Materials and Methods

Twenty-six patients with varus osteoarthritis undergoing navigated posterior-stabilized TKA (Triathlon, Stryker, Mahwah, NJ) were enrolled in this study. An image-free navigation system (Stryker 4.0 image-free computer navigation system; Stryker) was used for the operation. Registration was performed after minimum soft tissue release and osteophyte removal. Then, maximum internal and external rotational stress was manually applied on the knee with maximum extension and 90° flexion by the same surgeon, and the rotational angles were recorded using the navigation system. After knee implantation, the same rotational stress was applied and the rotational angles were recorded again. In addition, ROM was measured before surgery and at 1 month after surgery. The correlation between the amount of pre- and postoperative tibial rotation and ROM was statistically evaluated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 29 - 29
1 Jan 2016
Matsumoto T Takayama K Kawakami Y Ishida K Muratsu H Matsuzaki T Uefuji A Nakano N Matsushita T Kuroda R Kurosaka M
Full Access

Purpose

Surgeons sometimes encounter moderate or severe varus deformed osteoarthritic cases in which medial substantial release including semimembranosus is compelled to appropriately balance soft tissues in total knee arthroplasty (TKA). However, medial stability after TKA is important for acquisition of proper knee kinematics to lead to medial pivot motion during knee flexion. The purpose of the present study is to prove the hypothesis that step by step medial release, especially semimembranosus release, reduces medial stability in cruciate-retaining (CR) total knee arthroplasty (TKA).

Methods

Twenty CR TKAs were performed in patients with moderate varus-type osteoarthritis (10° < varus deformity <20°) using the tibia first technique guided by a navigation system (Orthopilot). During the process of medial release, knee kinematics including tibial internal rotation and anterior translation during knee flexion were assessed using the navigation system at 3 points; (1) after anterior cruciate ligament resection (pre-release), (2) medial tibial and femoral osteophyte removal and release of minimum deep layer of medial collateral ligament (minimum release) and (3) release of semimembranosus (semimembranosus release). In addition, the kinematics after all prostheses implantation (semimembranosus release group) were assessed and compared with those assessed in another 20 patients in which only minimum release was performed (minimum release group).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 65 - 65
1 Jan 2016
Muratsu H Takemori T Nagai K Matsumoto T Takashima Y Tsubosaka M Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction

Appropriate osteotomy alignment and soft tissue balance are essential for the success of total knee arthroplasty (TKA). The management of soft tissue balance still remains difficult and it is left much to the surgeon's subjective feel and experience.

We developed an offset type tensor system for TKA. This device enables objective soft tissue balance measurement with more physiological joint conditions with femoral trial component in place and patello-femoral (PF) joint reduced. We have reported femoral component placement decreased extension gap.

The purpose of the present study was to analyze the influence of femoral component size selection on the decrease of extension gap in posterior-stabilized (PS) TKA.

Material & Method

120 varus type osteoarthritic knees implanted with PS TKAs (NexGen LPS flex: Zimmer) were subjected to this study. All TKAs were performed using measured resection technique with anterior reference.

The femoral component size was evaluated intra-operatively using conventional femoral sizing jig. The selected femoral component size was expressed by the antero-posterior (AP) size increase (mm) comparing to that of original femoral condyles. Gap measurements were performed using a newly developed offset type tensor device applying 40lbs (178N) of joint distraction force. Firstly, conventional osteotomy gaps (mm) were measured at extension and flexion. Secondary, component gaps (mm) after femoral trial placement with PF joint reduced were evaluated at 0° and 90° of knee flexion.

To compare conventional osteotomy gaps and component gaps, estimated extension and flexion gaps were calculated by subtracting the femoral component thickness at extension (9mm) and flexion (11mm) from conventional osteotomy gaps respectively. The decrease of gap at extension and flexion were calculated with estimated gaps subtracted by component gaps. The simple linear regression analysis was used to evaluate the influence of selected femoral component size on the decrease of gap after femoral component placement.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 48 - 48
1 Jan 2016
Takayama K Matsumoto T Muratsu H Nakano N Shibanuma N Tei K Matsushita T Kuroda R Kurosaka M
Full Access

Purpose

The tibia first technique in unicompartmental knee arthroplasty (UKA) may have the advantage that surgeons can obtain a balanced flexion-extension gap. However, changes of the soft tissue tension during UKA has not been elucidated yet. The purpose of this study was to examine the correlation between the soft tissue tension before the femoral osteotomy and after the femoral component in place using the tensor in UKA.

Methods

Thirty UKAs for isolated medial compartmental osteoarthritis or idiopathic osteonecrosis were assessed. The mean age was 71.8±8.5 years old (range: 58–85), and the average coronal plane femorotibial angle (FTA) was 181.2±3.2 degree preoperatively. All the patients received a conventional medial Zimmer Unicompartmental High Flex Knee System (Zimmer Inc, Warsaw, Ind). The actual values of the proximal and posterior femoral osteotomy were calculated by adding the thickness of the bone saw blades to the thickness of the bony cut. Using a UKA tensor which designed to facilitate intra-operative soft tissue tension throughout the range of motion (ROM), the original gap before the femoral osteotomy, the component gap after the femoral osteotomy, and component placement were assessed under 20 lb distraction forces. (Figure 1)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 78 - 78
1 Jan 2016
Nakano N Matsumoto T Muratsu H Matsushita T Takayama K Kawakami Y Nagai K Kuroda R Kurosaka M
Full Access

Patients planning to undergo total knee arthroplasty (TKA), especially in Asian and Middle Eastern countries, usually expect to be able to perform activities requiring knee flexion such as sitting cross-legged or kneeling with ease after the surgery. Postoperative range of motion (ROM) can be affected by multiple factors such as the patient's gender, age, preoperative ROM, diagnosis, the surgeon's technique, the pre- and post-operative rehabilitation program, and the design of the prosthesis. Among these, the choice of the prosthesis depends on the surgeon's preference. As a result, several trials and studies have been conducted to improve postoperative ROM by modifying prosthesis design. The present study aimed to examine the results of TKA with the NexGen LPS-Flex system (Zimmer, Warsaw, Indiana), which is one of several high-flexion total knee prostheses that were designed to achieve a wide ROM for osteoarthritis in the valgus knee. A total of 27 primary TKAs in 26 osteoarthritis patients with valgus knee deformities (femorotibial angle (FTA) ≤ 170°) were performed using the NexGen LPS-Flex fixed prosthesis between July 2003 and December 2011. The patients included 2 men (7.7%, 2 knees) and 24 women (92.3%, 25 knees) with a mean age of 72.6 years (range, 59 to 83 years) at the time of the surgery. The mean duration of follow-up after surgery was 50.1 months (range, 24 to 126 months). Knee Society Knee Score (KSKS), Knee Society Function Score (KSFS), maximum flexion angle, maximum extension angle, and radiological femorotibial angle (FTA) were evaluated pre- and post-operatively. The mean preoperative KSKS and KSFS were 42.6 points (SD 7.5) and 41.1 points (SD 8.6), respectively, which improved after surgery to 82.2 points (SD 8.2) and 80.9 points (SD 7.6), respectively (P < 0.01). The maximum flexion angle improved from 109.1° (SD 23.1) to 117.3° (SD 12.4) postoperatively, but it did not reach statistical significance (P = 0.097). The preoperative maximum extension angle improved from −9.7° (SD 10.8) to −3.6° (SD 4.9) postoperatively (p < 0.05). The mean radiological FTA was 166.4° (SD 4.2; range: 155° − 170°) preoperatively and 172.4° (SD 2.7; range: 168° − 178°) at the final follow-up, and the difference was statistically significant (P < 0.01). None of the patients had undergone revision surgery by the final follow-up. As a conclusion, the results of the present study showed that the use of NexGen LPS-Flex implant in TKA for knee osteoarthritis with valgus deformity produced a satisfactory improvement in the clinical and radiological outcomes. Further studies on the outcomes of other prosthesis are needed to determine whether the NexGen LPS-Flex implant is advantageous for osteoarthritis patients with valgus knees who undergo TKA, and further large-scale studies with longer term follow-up are necessary to verify our results.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1144 - 1151
1 Aug 2015
Waki T Lee SY Niikura T Iwakura T Dogaki Y Okumachi E Kuroda R Kurosaka M

MicroRNAs (miRNAs ) are small non-coding RNAs that regulate gene expression. We hypothesised that the functions of certain miRNAs and changes to their patterns of expression may be crucial in the pathogenesis of nonunion. Healing fractures and atrophic nonunions produced by periosteal cauterisation were created in the femora of 94 rats, with 1:1 group allocation. At post-fracture days three, seven, ten, 14, 21 and 28, miRNAs were extracted from the newly generated tissue at the fracture site. Microarray and real-time polymerase chain reaction (PCR) analyses of day 14 samples revealed that five miRNAs, miR-31a-3p, miR-31a-5p, miR-146a-5p, miR-146b-5p and miR-223-3p, were highly upregulated in nonunion. Real-time PCR analysis further revealed that, in nonunion, the expression levels of all five of these miRNAs peaked on day 14 and declined thereafter.

Our results suggest that miR-31a-3p, miR-31a-5p, miR-146a-5p, miR-146b-5p and miR-223-3p may play an important role in the development of nonunion. These findings add to the understanding of the molecular mechanism for nonunion formation and may lead to the development of novel therapeutic strategies for its treatment.

Cite this article: Bone Joint J 2015; 97-B:1144–51.


Bone & Joint Research
Vol. 3, Issue 12 | Pages 328 - 334
1 Dec 2014
Harada Y Kokubu T Mifune Y Inui A Sakata R Muto T Takase F Kurosaka M

Objectives

To investigate the appropriate dose and interval for the administration of triamcinolone acetonide (TA) in treating tendinopathy to avoid adverse effects such as tendon degeneration and rupture.

Methods

Human rotator cuff-derived cells were cultured using three media: regular medium (control), regular medium with 0.1 mg/mL of TA (low TA group), and with 1.0 mg/mL of TA (high TA group). The cell morphology, apoptosis, and viability were assessed at designated time points.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 108 - 108
1 Jul 2014
Onishi Y Kawamoto T Ueha T Hara H Toda M Harada R Minoda M Morishita M Kurosaka M Akisue T
Full Access

Summary Statement

A novel transcutaneous CO2 therapy significantly enhanced the antitumor effectiveness of X-ray irradiation in human MFH xenografts The results strongly suggest that transcutaneous CO2 therapy could be a novel therapeutic tool for overcoming radioresistance in human malignancies.

Introduction

Hypoxia contributes to tumor radioresistance. In the presence of oxygen, reactive oxygen species (ROS) play crucial roles in cellular apoptosis to irradiation. We previously showed that a novel transcutaneous application of CO2 can improve hypoxia and that it induces apoptosis and decreases the expression of HIF-1α in sarcoma. Therefore, we hypothesised that a transcutaneous application of CO2 may increase radiosensitivity in sarcoma by improvement of hypoxic condition and increasing ROS production in tumors. The purpose of this study is to examine the effect of transcutaneous application of CO2 on radiosensitivity in human malignant fibrous histiocytoma (MFH) cells.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 350 - 350
1 Jul 2014
Lee S Okumachi E Dogaki Y Niikura T Iwakura T Waki T Nishida K Kurosaka M
Full Access

Summary Statement

Low-intensity pulsed ultrasound (LIPUS) enhanced osteogenic differentiation of osteoprogenitor cells derived from mouse induced pluripotent cells (iPSCs) without embryoid body formation. Our findings provide insights on the development of LIPUS as an effective technology for bone regeneration strategies using iPSCs.

Introduction

iPSCs represent a promising cell source for regenerative medicine such as bone regeneration because of their unlimited self-renewal property and ability of differentiation into all somatic cell types. Recently, we developed an efficient protocol for generating a highly homogeneous population of osteoprogenitor cells from embryonic stem cells by using a direct-plating method without EB formation step. It is well-recognised that LIPUS accelerates the fracture healing. There have been several reports showing that LIPUS stimulates the osteogenic differentiation of mesenchymal stem cells (MSCs) in vitro. To date, effect of LIPUS on iPSCs remains unknown. In this study, we investigated in vitro effect of LIPUS on osteogenic differentiation of osteoprogenitor cells derived from mouse iPS cells via a direct-plating method.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 343 - 343
1 Dec 2013
Hayashi S Fujishiro T Hashimoto S Kanzaki N Nishiyama T Kurosaka M
Full Access

Introduction:

Implant dislocations are often caused by implant or bone impingement, and less impingement is critical to prevent dislocations. Several reports demonstrated that greater femoral offset delayed bony impingement and led to an improved range of motion (ROM) after THA. Therefore, an increase in the femoral offset may improve ROM and decrease implant dislocation. The aim of this study was to clarify the effect of the femoral offset in avoiding component or bony impingement after total hip arthroplasty (THA).

Methods:

Seventy-eight patients underwent THA with a Pinnacle cup and Summit stem (DePuy). Intraoperative kinematic analysis was performed with a navigation system, which was used to obtain intraoperative range of motion (ROM) measurements during trial insertion of stems of 2 different offset lengths with the same head size. Further, ROM was also measured after actual component insertion.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 521 - 521
1 Dec 2013
Sasaki H Ishida K Tei K Shibanuma N Matsumoto T Kuroda Y Oka S Matsuzaki T Uefuji A Tateishi H Kuroda R Kurosaka M
Full Access

Introduction

Increased long-term survival of TKA is becoming more important. Several studies have confirmed that optimal positioning and alignment of prosthetic components is crucial for the best long-term results. Therefore, the purpose of the current study was to compare the postoperative alignment and sizing of femoral prosthesis among patients performed by 3 different navigation systems.

Methods

Twenty patients who underwent primary TKA (E. motion; B. Braun Aesculap, Tuttlingen, Germany) using a CT-free navigation system (OrthoPilot v 4.2) by modified gap technique were enrolled in this study. The results of this study group were retrospectively compared with those in a control group of 20 matched-paired posterior stabilized TKAs (Triathlon;Stryker; Mahwah, NJ, USA) which were using another CT-free navigation system (Stryker Navigation System) by measured technique and 20 matched-paired posterior stabilized TKAs (Press-fit Condylar prosthesis; DePuy, Tokyo, Japan) using CT-based navigation system (VectorVision) by measured technique. Several parameters were evaluated for each patient using Athena Knee (Softcube Co, Ltd. Osaka, Japan), 3-D image-matching software. The coronal component angles and sagittal component angles were measured in relation to mechanical axis (MA). In addition, axial femoral component angle was measured in relation to surgical epicondylar axis (SEA) and axial tibial component angle was measured in relation to Akagi line.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 384 - 384
1 Dec 2013
Kuroda Y Ishida K Matsumoto T Sasaki H Oka S Tei K Kawakami Y Matsuzaki T Uefuji A Nagai K Tsumura N Kuroda R Kurosaka M
Full Access

Background:

The axis of the fibula in the sagittal plane are known as a landmark for the extramedullary guide in order to minimize posterior tibial slope measurement error in the conventional total knee arthroplasty (TKA). However, there are few anatomic studies about them. We also wondered if the fibula in the coronal plane could be reliable landmark for the alignment of the tibia. This study was conducted to confirm whether the fibula is reliable landmark in coronal and sagittal plane.

Methods:

We evaluated 60 osteoarthritic knees after TKA using Athena Knee (SoftCube Co, Ltd, Osaka, Japan) 3-D image-matching software. Angle between the axis of the fibula (FA) and the mechanical axis (MA) in the coronal and sagittal plane were measured.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 442 - 442
1 Dec 2013
Muratsu H Kirizuki S Kihara S Takeoka Y Matsumoto T Maruo A Miya H Kuroda R Kurosaka M
Full Access

[Introduction]

Rapid increase of aged population has been one of major issue affecting national health care plan in Japan. In 2006, Japanese Orthopaedic Association indicated a new clinical entity of musculoskeletal ambulation disorder symptom complex (MADS) to define the higher risk of fall and ambulatory disability in the elderly population caused by musculoskeletal disorders. Osteoarthritis of the knee is one of major cause of MADS. The number of patients with MADS underwent total knee arthroplasty (TKA) had been increased in Japan, and also expected to increase worldwide in the near future. The effectiveness of TKA for the patient with MADS would be a key issue for the patient satisfaction in TKA. In the present study, we analyzed the influence of pre-operative factors on the ambulatory functions in the patients of primary TKA.

[Material & Method]

132 patients with osteoarthritic knees implanted with posterior-stabilized (PS) TKAs were subjected to this study. There were 113 female and 19 male patients. The mean age of the patients was 73.6 years (range, 59 to 87 years). Patients were pre-operatively subjected to 2 functional performance tests which were essential tests for MADS diagnosis. Firstly, 3 meter timed up and go test (TUG) was used to evaluate ambulation ability. Secondary one leg standing time (ST) with open eyes was measured with both operated and non-operated leg to assess balancing ability. MADS was diagnosed if TUG and ST were not less than 11 seconds and/or less than 15 seconds respectively. The influence of each pre-operative factor was evaluated simple linear regression analysis (p < 0.05). Pre-operative factors consisted of age, sex, weight, height, BMI, standing femoro-tibial angle (FTA) and active knee range of motion.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 180 - 180
1 Dec 2013
Takeoka Y Muratsu H Kihara S Matsumoto T Miyaji N Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective

The goal of total knee arthroplasty (TKA) is to achieve a stable and well-aligned tibiofemoral and patello-femoral (PF) joint, aiming at long-term clinical patient satisfaction. The surgical principles of both cruciate retaining (CR) and posterior stabilized (PS) TKA are accurate osteotomy and proper soft tissue balancing. We have developed an offset-type tensor, and measured intra-operative soft tissue balance under more physiological joint conditions with femoral component in place and reduced PF joint.

In this study, we measured intra-operative soft tissue balance and assessed the early post-operative knee joint stability quantitatively, and compared these parameters between CR and PS TKA.

Material and Method

Seventy patients with varus osteoarthritis of the knee underwent TKAs (35 CR TKAs: CR and 35 PS TKAs: PS). Mean varus deformity in standing position was 9.8 degrees in CR, and 10.7 degrees in PS (p = 0.45). All TKAs were performed by a single surgeon with measured resection technique. The external rotation of posterior femoral condyle osteotomy was performed according to surgical epicondylar axis (SEA) in pre-operative CT. We measured intra-operative soft tissue balance using an offset-type tensor with 40 lbs of joint distraction force at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. The joint component gap (mm) and varus angle (degrees) were measured at each flexion angle.

Four weeks after operation, we evaluated the knee stability at extension by varus and valgus stress radiography using Telos (10 kg) and at flexion by epicondylar view with 1.5 kg weight at the ankle. We measured joint separation distance at medial as medial joint looseness (MJL) and at lateral as lateral joint looseness (LJL). Joint looseness was defined as the average of MJL and LJL.

Intra-operative measurements and post-operative joint stabilities were compared between CR and PS using unpaired t-test.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 556 - 556
1 Dec 2013
Tei K Matsumoto T Shibanuma N Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femolo-tibial joint as well as posterior-stabilized polyethylene insert, even if posterior cruciate ligament (PCL) is sacrificed after total knee arthroplasty (TKA). The purpose of this study is an investigation of in vivo kinematics of three different tibial insert designs using computer assisted navigation system intra-operatively in TKA.

Materials and Methods

Sixty-four consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker, New Jersey, USA) were performed using computer assisted navigation system. During surgery, three different designs of polyethylene tibial trial inserts (PS, CS, and cruciate-retaining (CR) polyethylene insert) were inserted respectively after implantation of femoral and tibial components. The kinematic parameters of the soft-tissue balance were obtained by interpreting kinematics curve, which display bicompartmental gaps throughout the range of motion (ROM) after implantation of each trial insert (Figure. 1). During record of kinematics, the surgeon gently lifted the experimental thigh three times, flexing the hip and knee. Deviation of these three values in each ROM was calculated in each tibial insert in each patient for descriptive analysis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 34 - 34
1 Apr 2013
Koga T Niikura T Lee SY Dogaki Y Okumachi E Waki T Ueha T Sakai Y Oe K Miwa M Kurosaka M
Full Access

Introduction

It is well known that blood flow is a critical key component of fracture repair. Previously, we demonstrated that transcutaneous application of CO2 increased blood flow in the human body. To date, there has been no report investigating the effect of the carbonated therapy on fracture repair.

Hypothesis

We hypothesized that the transcutaneous application of CO2 to fracture site would accelerate fracture repair.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 88 - 88
1 Apr 2013
Kawakami Y Hiranaka T Hida Y Chinzei N Uemoto H Doita M Kurosaka M Tsuji M
Full Access

Introduction

In most cases of stable type medial femoral neck fracture and some cases of dislocated medial femoral neck fracture, internal fixation was undertaken. Dual SC Screw (DSCS) System is an internal fixation device which has sliding mechanism and preventing mechanism of back out of the screw. The purpose of this study is to evaluate the results and complication of medial femoral neck fracture treated with DSCS.

Methods

Fifty two patients operated for fractures of the medial femoral neck with DSCS were identified as the study population. All patients followed up at least 2years. Outcome measures included the period of bone union, revision surgery, operating times and clinical symptoms and complication.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 91 - 91
1 Apr 2013
Okumachi E Lee SY Niikura T Koga T Dogaki Y Waki T Kurosaka M
Full Access

Introduction

Recently, some case reports have been published, in which nonunions were successfully healed with parathyroid hormone 1–34 (PTH) administration. Previously, we demonstrated that the intervening tissue at the nonunion site contains multilineage mesenchymal progenitor cells and plays an important role during the healing process of nonunion. We investigated the effect of PTH on osteogenic differentiation of human nonunion tissue-derived cells (NCs) in vitro.

Hypothesis

We hypothesized that PTH directly promoted osteogenic differentiation of NCs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 23 - 23
1 Apr 2013
Kawakami Y Ii M Kawamoto A Matsumoto T Mifune Y Shoji T Fukui T Kuroda R Kurosaka M Asahara T
Full Access

Introduction

Failures in fracture healing are mainly caused by a lack of neovascularization. We have previously demonstrated that G-CSF-mobilized peripheral blood (GM-PB) CD34+ cells, an endothelial progenitor enriched cell population, contributed to fracture healing via vasculogenesis and osteogenesis. We postulated the hypothesis that local transplantation of culture expanded bone marrow (cEx-BM) CD34+ cells could exhibit therapeutic potential for fracture healing.

Materials

BM CD34+ cells were cultured in specific medium with 5 growth factors for 1week. A reproducible model of femoral fracture was created in nude rats with periosteum cauterization, which leads to nonunion at 8 weeks post-fracture. Rats received local administration of the following cells or PBS alone(1)cEx-BM, (2)BM, (3)GM-PB CD34+ cells or (4)PBS.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 32 - 32
1 Apr 2013
Lee S Niikura T Koga T Dogaki Y Okumachi E Waki T Kurosaka M
Full Access

Introduction

Low-intensity pulsed ultrasound (LIPUS) has been reported to enhance healing of fracture and nonunion. Bone morphogenetic protein-7 (BMP-7) has also been reported to promote bone formation. Recently, we demonstrated progenitor cells with osteogenic/chondrogenic differentiation potential existed in human fracture hematoma and nonunion tissue.

Hypothesis

We hypothesised the combined application of LIPUS and BMP-7 would cause major effect on osteogenesis of hematoma-derived cells (HCs) and nonunion tissue-derived cells (NCs).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 24 - 24
1 Apr 2013
Kawakami Y Kuroda T Matsumoto T Kwon S Ii M Kawamoto A Mifune Y Shoji T Kuroda R Kurosaka M Asahara T
Full Access

Introduction

CXC chemokine receptor 4 (CXCR4) is a specific receptor for stromal-derived-factor 1 (SDF-1). SDF-1/CXCR4 interaction contributes to the regulation of endotherial progenitor cell (EPC) recruitment in ischemic tissues. The purpose of this study is to investigate the mechanistic function of CXCR4 on EPCs for bone fracture healing.

Materials and methods

We made CXCR4 gene knockout mice using the Cre/loxP system. A reproducible model of femoral fracture was created in both Tie2-Cre CXCR4 knockout mice (CXCR4KO) and wild type mice (control). To evaluate gain function of the SDF-1/CXCR4 pathway, we set three groups of the SDF-1 intraperitoneally injected group, wild type group, and SDF-1 injected CXCR4 KO group.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 55 - 55
1 Apr 2013
Kawakami Y Hiranaka T Niikura T Matsuzaki T Hida Y Uemoto H Doita M Tsuji M Kurosaka M
Full Access

Introduction

Plate fixations have been recommended for dislocated clavicle fractures. However, existing plates are inadequate for morphological compatibility with the clavicle. The aim of this study is to measure the anatomical shape of the clavicle and to compare the radiographical and clinical outcomes of our tree-dimensional (3D) reconstruction plate with conventional straight plate.

Methods

Chest CT image of 15 patients with normal clavicle were analyzed. Their clavicles were reconstructed and measured their anatomical variables. A hospital-based case-control study was conducted, including a consecutive series of 52 patients with displaced midshaft clavicle fractures. 3D reconstruction plate was used for 26 patients and another 26 patients were treated with conventional straight plate. Outcome measures included the period of bone union, revision surgery, operating times and clinical symptoms using DASH score.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 56 - 56
1 Apr 2013
Dogaki Y Niikura T Lee S Koga T Okumachi E Waki T Kurosaka M
Full Access

Introduction

Our previous study using microarray analysis showed that Rad (Ras associated with diabetes) was highly expressed in nonunion. The purpose of this study is to investigate the gene expression and immunolocalization of Rad, and other Ras-related G proteins: Rem1 and Rem2 in fracture/nonunion site using rat experimental models.

Hypothesis

We hypothesized that Rad had a significant role in nonunion formation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 84 - 84
1 Apr 2013
Koga T Niikura T Lee SY Dogaki Y Okumachi E Waki T Kurosaka M
Full Access

Introduction

The hematoma occurring at a fracture site is known to play an important role in fracture healing. Previously, we demonstrated that fracture hematoma contained multilineage mesenchymal progenitor cells. On the other hand, the process of fracture healing is associated by two different mechanisms, intramembranous and endochondral. However, there are no reports proving the details about cellular analysis in the process of endochondoral ossification.

Hypothesis

We hypothesized that one of the cell origins for endochondral ossification after fracture was hematoma.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 80 - 80
1 Apr 2013
Dogaki Y Lee S Niikura T Koga T Okumachi E Waki T Kakutani K Nishida K Kurosaka M
Full Access

Introduction

iPSCs represent a promising cell source for bone regeneration. To generate osteoprogenitor cells, most protocols use the generation of embryoid bodies (EBs). However, these protocols give rise to heterogeneous population of different cell lineage.

Hypothesis

We hypothesized that a direct plating method without EB formation step could be an efficient protocol for generating a homogeneous population of osteoprogenitor cells from iPSCs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 82 - 82
1 Apr 2013
Dogaki Y Lee S Niikura T Koga T Okumachi E Waki T Kurosaka M
Full Access

Introduction

Parathyroid hormone 1–34 (PTH) has been reported to accelerate fracture healing. Previously, we demonstrated human fracture hematoma contained osteo-/chondro-progenitor cells. To date, there has been no study investigating the effect of PTH on fracture hematoma-derived cells (HCs) in vitro.

Hypothesis

We hypothesized PTH treatment affected osteogenesis and chondrogenesis of HCs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 28 - 28
1 Apr 2013
Niikura T Lee SY Koga T Dogaki Y Okumachi E Waki T Kurosaka M
Full Access

Introduction

Many surgeons assess biological activity of fracture nonunion by the presence or absence of callus using radiograph. However, it is difficult to assess biological activity only by radiographic appearance. Bone scintigraphy reflects blood supply and bone metabolism and is possibly useful to assess biological activity in nonunion cases.

Hypothesis

We hypothesized that poor callus visualization did not always mean lack of biological activity.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 90 - 90
1 Apr 2013
Kawakami Y Matsumoto T Ii M Kawamoto A Kuroda R Mifune Y Shoji T Fukui T Kurosaka M Asahara T
Full Access

Introduction

The therapeutic potential of hematopoietic stem cells for fracture healing has been demonstrated with mechanistic insight of vasculogenesis and osteogenesis enhancement. Lnk has recently been proved an essential inhibitory signaling molecule in SCF-c-Kit signaling pathway for stem cell self-renewal demonstrating enhanced hematopoietic and osteogenic reconstitution in Lnk-deficient mice. We investigated the hypothesis that down regulation of Lnk enhances regenerative response via vasculogenesis and osteogenesis in fracture healing.

Methods

A reproducible model of femoral fracture was created in mice. Immediately after fracture creation, mice received local administration of the following materials with AteloGene, 10μM (1)Lnk siRNA, (2)control siRNA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 174 - 174
1 Mar 2013
Fujishiro T Nishiyama T Hayashi S Kanzaki N Hashimoto S Shibanuma N Kurosaka M
Full Access

Background

The cementless acetabular component fixed with several screws is one of the most widely used approaches in THA. These screws rely on contact pressure and the resultant friction between the screw head and the cup to control translation and angulation of the prosthesis. However, intraoperative change of the acetabular component alignment during screw fixation should be hardly detected. Acetabular component alignment can be assessed using computer-assisted navigation systems with realtime adjustments for component position. The purpose of the current study was to evaluate intraoperative change of acetabular component alignment during screw fixation using navigation system.

Patients and Methods

Primary THAs were performed in 74 hips using CT based fluoroscopic matching navigation system (VectorVision, BrainLAB). The patients were 18 men and 56 women with a mean age of 64.4 years (range, 47–78 years) at operation. Intraoperative acetabular component inclination and anteversion were measured at the time of press-fit, and after screw fixation using the cup verification function in the system. Mean of the absolute difference between at the time of press-fit and after screw fixation was evaluated as intraoperative change of acetabular component. We measured the distance from the center of the femoral head to the inter-teardrop line as a horizontal and vertical reference on the postoperative radiograph. The number of screws was also investigated.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 123 - 123
1 Mar 2013
Matsumoto T Muratsu H Kubo S Tei K Sasaki H Matsuzaki T Matsushita T Kurosaka M Kuroda R
Full Access

Backgrounds

In order to permit soft tissue balancing under more physiological conditions during total knee arthroplasties (TKAs), we developed an offset type tensor to obtain soft tissue balancing throughout the range of motion with reduced patella-femoral (PF) and aligned tibiofemoral joints and reported the intra-operative soft tissue balance assessment in cruciate-retaining (CR) and posterior-stabilized (PS) TKA [1, 2]. However, the soft tissue balance in unicompartmental knee arthroplasty (UKA) is unclear. Therefore, we recently developed a new tensor for UKAs that is designed to assist with soft tissue balancing throughout the full range of motion. The first purpose of the present study is to assess joint gap kinematics in UKA. Secondly, we attempted to compare the pattern in UKA with those in CR and PS TKA with the reduced PF joint and femoral component placement, which more closely reproduces post-operative joint alignment.

Methods

Using this tensor, we assessed the intra-operative joint gap measurements of UKAs performed at 0, 10, 30, 45, 60, 90, 120 and 135° of flexion in 20 osteoarthritic patients. In addition, the kinematic pattern of UKA was compared with those of CR and PS TKA that were calculated as medial compartment gap from the previous series of this study.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 257 - 257
1 Mar 2013
Matsuzaki T Matsumoto T Kubo S Muratsu H Matsushita T Oka S Nagai K Kurosaka M Kuroda R
Full Access

Introduction

Appropriate intraoperative soft tissue balancing is recognized to be essential in total knee arthroplasty (TKA). However, it has been rarely reported whether intraoperative soft tissue balance reflects postoperative outcomes. In this study, we therefore assessed the relationship between the intra-operative soft tissue balance measurements and the post-operative stress radiographs at a minimum 1-year follow-up in cruciate-retaining (CR) TKA, and further analyzed the postoperative clinical outcome.

Methods

The subjects were 25 patients diagnosed with osteoarthritis with varus deformity and underwent primary TKA. The mean age at surgery was 72.0 ± 7.5 years (range, 47–84 years). The Surgeries were performed with the tibia first gap technique using CR-TKA (e motion, B. Braun Aesculap) and the image-free navigation system (Orthopilot). We intraoperatively measured varus ligament balance (°, varus angle; VA) and joint component gap (mm, center gap; CG) at 10° and 90° knee flexion guided by the navigation system, with the patella reduced. At a minimum 1-year follow-up, post-operative coronal laxity at extension was assessed by varus and valgus stress radiographs of the knees with 1.5 kgf using a Telos SE arthrometer (Fa Telos) and that at flexion was assessed by epicondylar view radiographs of the knees with a 1.5-kg weight at the ankle. After calculating postoperative VA and CG from measurements of radiographs, measurements and preoperative and postoperative clinical outcome, such as Knee Society Clinical Rating System (Knee score; KSS, Functional score; KSFS) and postoperative knee flexion, were analyzed statistically using linear regression models and Pearson's correlation coefficient.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 217 - 217
1 Mar 2013
Kihara S Muratsu H Matsumoto T Kirizuki S Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction

Rapid increase of aged population has been one of major issue affecting national health care plan in Japan. In 2006, Japanese Orthopaedic Association proposed the clinical entity of musculoskeletal ambulation disorder symptom complex (MADS) to define the elderly population with high risk of fall and ambulatory disability caused by musculoskeletal disorders. Osteoarthritis of the knee is one of major cause of MADS. The number of patients with MADS underwent total knee arthroplasty (TKA) had been increased in Japan, and also expected to increase worldwide in the near future. The effectiveness of TKA for the patient with MADS has not been well evaluated. In the present study, we analyzed the early post-operative functional recovery after TKA using 2 simple performance tests to diagnose MADS.

Material & Method

Fifty patients with varus type osteoarthritic knees implanted with posterior-stabilized (PS) TKAs were subjected to this study. There were 44 female and 6 male patients. The mean age of the patients was 71.6 years (range, 59 to 84 years). Patients were subjected to 2 functional performance tests which were essential tests for MADS diagnosis. Firstly, 3 meter timed up and go test (TUG) was used to evaluate ambulation. Secondary one leg standing time with open eyes was measured to assess balancing ability. 2 tests were performed pre-operatively, 2 weeks after surgery and at discharge (23.8 days po). MADS was defined to be diagnosed if TUG and one leg standing time was not less than 11 seconds and/or less than 15 seconds respectively. Each parameter was compared among at above mentioned three time points -using a repeated measured analysis of variance (p<0.05).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 54 - 54
1 Sep 2012
Fujishiro T Nishiyama T Hayashi S Kanzaki N Takebe K Kurosaka M
Full Access

Background

Total hip arthroplasty for Crowe type IV developmental dysplasia of the hip is a technically demanding procedure. Restoration of the anatomical hip center frequently requires limb lengthening in excess of 4 cm and increases the risk of neurologic traction injury. However, it can be difficult to predict potential leg length change, especially in total hip arthroplasty for Crowe type IV developmental hip dysplasia. The purpose of the present study was to better define features that might aid in the preoperative prediction of leg length change in THAs with subtrochanteric femoral shortening osteotomy for Crowe type IV developmental dysplasia of the hip.

Patients and Methods

Primary total hip arthroplasties with subtrochanteric femoral shortening osteotomy were performed in 70 hips for the treatment of Crowe type IV developmental hip dysplasia. The patients were subdivided into two groups with or without iliofemoral osteoarthritis. Leg length change after surgery was measured radiographically by subtracting the amount of resection of the femur from the amount of distraction of the greater trochanter. Preoperative passive hip motion was retrospectively reviewed from medical records and defined as either higher or lower motion groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 183 - 183
1 Sep 2012
Takahara S Muratsu H Nagai K Matsumoto T Kubo S Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective

Although both accurate component placement and adequate soft tissue balance have been recognized as essential surgical principle in total knee arthroplasty (TKA), the influence of intra-operative soft tissue balance on the post-operative clinical results has not been well investigated. In the present study, newly developed TKA tensor was used to evaluate soft tissue balance quantitatively. We analyzed the influence of soft tissue balance on the post-operative knee extension after posterior-stabilized (PS) TKA.

Materials and Methods

Fifty varus type osteoarthritic knees implanted with PS-TKAs were subjected to this study. All TKAs were performed using measured resection technique with anterior reference method. The thickness of resected bone fragments was measured.

Following each bony resection and soft tissue releases, we measured soft tissue balance at extension and flexion of the knee using a newly developed offset type tensor. This tensor device enabled quantitative soft tissue balance measurement with femoral trial component in place and patello-femoral (PF) joint repaired (component gap evaluation) in addition to the conventional measurement between osteotomized surfaces (osteotomy gap evaluation). Soft tissue balance was evaluated by the center gap (mm) and ligament balance (°; positive in varus) applying joint distraction forces at 40 lbs (178 N).

Active knee extension in spine position was measured by lateral X-ray at 4 weeks post-operatively. The effect of each parameter (soft tissue balance evaluations, thickness of polyethylene insert and resected bone) on the post-operative knee extension was evaluated using simple linear regression analysis. P<0.05 was considered statistically significant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 129 - 129
1 Sep 2012
Oka S Matsumoto T Kubo S Muratsu H Sasaki H Matsushita T Kuroda R Kurosaka M
Full Access

Introductions

In cruciate-retaining total knee arthroplasty (TKA), among many factors influencing post-operative outcome, increasing the tibial slope has been considered as one of the beneficial factors to gain deep flexion because of leading more consistent femoral rollback and avoiding direct impingement of the insert against the posterior femur. In contrast, whether increasing the tibial slope is useful or not is controversial in posterior-stabilized (PS) TKA, Under such recognition, accurate soft tissue balancing is also essential surgical intervention for acquisition of successful postoperative outcomes in TKA. In order to permit soft tissue balancing under more physiological conditions during TKAs, we developed an offset type tensor to obtain soft tissue balancing throughout the range of motion with reduced patello-femoral(PF) and aligned tibiofemoral joints and have reported the relationship between intra-operative soft tissue balance and flexion angles. In this study, we therefore assessed the relationship between intra-operative soft tissue balance assessed using the tensor and the tibial slope in PS TKA.

Materials and methods

Thirty patients aged with a mean 72.6 years were operated PS TKA(NexGen LPS-Flex, Zimmer, Inc. Warsaw, IN) for the varus type osteoarthritis. Following each bony resection and soft tissue release using measure resection technique, the tensor was fixed to the proximal tibia and femoral trial prosthesis was fitted. Assessment of the joint component gap (mm) and the ligament balance in varus (°)was carried out at 0, 10, 45, 90and 135degrees of knee flexion. The joint distraction force was set at 40lbs. Joint component gap change values during 10-0°,45-0°, 90-0°, 135-0° flexion angle were also calculated. The tibial slopes were measured by postoperative lateral radiograph. The correlation between the tibial slope and values of soft tissue balance were assessed using linear regression analysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 242 - 242
1 Jun 2012
Tei K Shibanuma N Kubo S Matsumoto T Matsumoto A Tateishi H Kurosaka M Kuroda R
Full Access

Introduction

Achieving high flexion after total knee arthroplasty (TKA) is one of the most important clinical results, especially in eastern countries where the high flexion activities, such as kneeling and squatting, are part of the important lifestyle. Numerous studies have examined the kinematics after TKA. However, there are few numbers of studies which examined the kinematics during deep knee flexion activities. Therefore, in the present study, we report analysis of mobile-bearing TKA kinematics from extension to deep flexion kneeling using 2D-3D image matching technique.

Materials and Methods

The subjects were 16 knees of 8 consecutive patients (all women, average age 75.9), who underwent primary mobile-bearing PS TKA (P.F.C. sigma RP-F: Depuy Orthopedics Inc., Warsaw, IN, USA) between February 2007 and May 2008. All cases were osteoarthritis with varus deformity. Postoperative radiographs were taken at the position of extension, half-squatting and deep flexion kneeling 3 month after the surgery, and the degrees of internal rotation of the tibial component was measured by 2D-3D image matching technique. Pre- and post-operative ROM was recorded. Then, we compared the absolute value and relative movement of tibial internal rotation between extension, half-squatting and deep flexion kneeling, and evaluated the correlation of the ROM and the internal rotation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 237 - 237
1 Jun 2012
Takayama K Kubo S Matsumoto T Ishida K Sasaki K Matsushita T Kurosaka M Kuroda R
Full Access

Introduction

Total knee arthroplasty (TKA) with a computer-assisted navigation system has been developed to improve the accuracy of the alignment of osteotomies and implantations. One of the most important goals of TKA is to improve the flexion angle. Although accurate soft tissue balancing has been recognized as an essential surgical intervention influencing flexion angle, the direct relationship between post-operative flexion angle and intra-operative soft tissue balance during TKA, has little been clarified. In the present study, therefore, we focused on the relationship between them in cruciate-retaining (CR) TKA with a navigation system.

Materials and methods

The subjects were 30 consecutive patients (2 men, 28 women), who underwent primary CR TKA (B. Braun Aesculap, e-motion) between May 2006 and December 2009. TKAs were performed using a image-free navigation system (OrthoPilot; B. Braun Aesculap, Tuttlingen, Germany). All cases were osteoarthritis with varus deformity. Average patient age at the time of surgery was 74.0 years (range, 62-86 years). After all bony resections and soft tissue releases were completed appropriately using a navigation system with tibia-first gap technique, a tensor was fixed to the proximal tibia and the femoral trial was fitted. Using the tensor that is designed to facilitate soft tissue balance measurements throughout the range of motion with a reduced patello-femoral (PF) joint and femoral component in place, the joint component gap and ligament balance (varus angle) were measured after the PF joint reduced and femoral component in place (Fig.1). Assessments of joint component gap and ligament balance were carried out at 0°, 30°, 60°, 90°, 120° flexion angle, which were monitored by the navigation system. Joint component gap change values during 30°- 0°, 60°- 0°, 90°- 0°, 120°- 0° flexion angle were calculated. The correlation between post operative flexion angles and pre-operative flexion angle, intra-operative joint component gaps, joint component gap change values and ligament balances were assessed using linear regression analysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 143 - 143
1 Jun 2012
Matsumoto T Kubo S Muratsu H Ishida K Takayama K Matsushita T Tei K Kurosaka M Kuroda R
Full Access

Using a tensor for total knee arthroplasty (TKA) that is designed to facilitate soft tissue balance measurements with a reduced patello-femoral (PF) joint, we examined the influence of pre-operative deformity on intra-operative soft tissue balance during posterior-stabilized (PS) TKA. Joint component gap and varus angle were assessed at 0, 10, 45, 90 and 135° of flexion with femoral trial prosthesis placed and PF joint reduced in 60 varus type osteoarthritic patients. Joint gap measurement showed no significant difference regardless the amount of pre-operative varus alignment. With the procedures of soft tissue release avoiding joint line elevation, however, intra-operative varus angle with varus alignment of more than 20 degrees exhibited significant larger values compared to those with varus alignment of less than 20 degrees throughout the range of motion. Accordingly, we conclude that pre-operative severe varus deformity may have the risk for leaving post-operative varus soft tissue balance during PS TKA.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 440 - 440
1 Nov 2011
Tei K Matsumoto T Kubo S Sasaki K Ishida K Shibanuma N Muratsu H Kurosaka M Kuroda R
Full Access

Recently, many researches of minimal incision surgery (MIS) total knee arthroplasty (TKA) have been reported, however very few of these contain clinical results. Regardless of this, MIS TKA is widely promoted as an improvement over traditional TKA. Although traditional TKA allows for excellent visualization, component orientation, fixation, and has been associated with remarkable long-term implant survival, many patients expect an extremely small incision, minimal or no pain and discomfort associated with their surgery, and certainly no increase in the complication rate. While there is some evidence that short term benefits may occur, there is concern that there may be an increase in complications with the use of MIS technique. We report here cases that malalignments in early phase were occurred after MIS TKAs. A consecutive series of MIS TKA for varus osteoarthritis undertaken by 2 surgeons at 2 centers during 2-year priod (2006–2007) was reviewed. During this interval, 50 MIS TKAs were performed. The mean age was 75.6 years (range 54 to 88 years). Cases for post-operatively infection were excluded. There were 2 cases that early failures due to varus sinking of tibial component were confirmed in early phase (7 and 3 months after primary surgery). We analyzed data between early failed cases and non-failed cases. Patients with early failure were younger, which showed a trend toward significance (p=0.11; failed; 66.5, non-failed; 75.9 years). There was no difference in amount of both medial and lateral side of distal femoral cut between early failed cases and non-failed cases. Proximal tibial cut was significantly larger in early failed cases compared with non-failed cases (p=0.01; failed; 16.5±4.5, nonfailed; 11.4±6.6). There was no difference in Femorotibial angle (FTA) after surgery between them. Substantial backgrounds of occurring early failure after MIS TKA are not still clarified, however, very early failure were occurred in patients, who had significant large cut of proximal tibia, in our experienced cases. MIS TKA may lead to varus imbalance due to increased amount of bony cut and decreased medial soft tissue release. Henceforth, the high prevalence of MIS failures occurring in early phase is disturbing, because of limited working space and warrants further investigation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 464 - 464
1 Nov 2011
Matsumoto T Kubo S Muratsu H Ishida K Tei K Sasaki K Matsushita T Kurosaka M Kuroda R
Full Access

Purpose: A common difficulty with manually-performed total knee arthroplasties (TKAs) is obtaining accurate intra-operative soft tissue balancing, an aspect of this procedure that surgeons traditionally address through their “subjective feel” and experience with an unphysiological joint condition. We have therefore developed a new tensor for TKAs that enables us to assess for soft tissue balancing throughout the range of motion about the knee with a reduced patello-femoral (PF) joint and femoral component in place. This tensor permits us to intra-operatively reproduce the post-operative alignment of the PF and tibio-femoral joints. The main purpose of this study is to compare ligament balance in cruciate-retaining (CR) and posterior-stabilized (PS) TKAs.

Methods: Using the tensor, we intra-operatively compared the ligament balance measurements of CR and PS TKAs performed at 0, 10, 45, 90 and 135° of flexion, with the patella both everted and reduced. From a group of 40 consecutive females (40 varus osteoarthritic knees) blinded to the type of implant received, we prospectively randomized 20 patients to receive a CR TKA (NexGen CR Flex) and the other 20 patients a PS TKA (NexGen LPS Flex). The CR TKA group had a mean age of 73.7 ± 1.3 years while the PS TKA group had a mean age of 73.8 ± 1.7 years.

Results: The mean values of varus angle in CR TKA with the knee at 0, 10, 45, 90 and 135 degrees of flexion were 3.0, 3.2, 2.7, 4.2 and 5.1 ° with the patella everted, and 3.9, 4.2, 2.5, 2.0 and 2.0 ° with the patella reduced. The mean values of varus angle in PS TKA at these same degrees of flexion, respectively, were 3.0, 4.1, 6.0, 6.2 and 6.1 ° with the patella everted, and 3.8, 4.1, 6.3, 6.3 and 4.9 ° with the patella reduced. While the ligament balance measurements with a reduced patella of PS TKAs slightly increased in varus from extension to mid-range of flexion (p< 0.05), these values slightly decreased for CR TKA (p< 0.05). Additionally, the ligament balance at deep knee flexion was significantly smaller in varus for both types of prosthetic knees when the PF joint was reduced (p< 0.05).

Conclusion: Accordingly, we conclude that the ligament balance kinematic patterns differ between everted and reduced patellae, as well as between PS and CR TKA.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 465 - 465
1 Nov 2011
Ishida K Matsumoto T Kubo S Tsumura N Kitagawa A Kurosaka M Kuroda R
Full Access

Background: The use of computer-assisted navigation system had proved to result in consistently accurate alignment of prosthesis in total knee arthroplasty (TKA), however, the clinical midterm to long-term results remains unclear. The objective of this study is to investigate whether clinical results after computer-assisted TKA is superior to the conventional surgical method at midterm, minimum for 5 years follow-up.

Materials: From October 2002 to May 2003, we implanted 30 posterior stabilized total knee prostheses (PFC Sigma; DePuy Inc) using a computed tomography-free navigation system (Vector Vision) for patients diagnosed as osteoarthritis. A control group of 30 matched total knee prostheses of the same type were implanted via a classical, surgeon-controlled technique. Midterm 5 year clinical results including range of motion and Knee Society Clinical Rating Score were compared with these groups. The navigation group was comprised of 23 women and 4 men with a mean age of 81.0 years (range: 56–89 years) at final follow-up and the manual group was comprised of 23 women and 4 men with a mean age of 78.2 years (range: 51–87 years).The results were analyzed statistically and differences of p < 0.05 were considered statistically significant.

Results: Mean follow-up duration was 68.9 months (range: 60–78 months) in the navigation group and 72.8 months (range: 60–80 months) in the manual group. Total 6 patients (3 patients in each group) were lost to follow-up because of their death or lost contact. The follow-up rate was 90 %. No revision or reoperations were required in this study. The average preoperative knee society knee score (KSS) and knee society functional score (KSFS) in the navigation group were 52.9 points (range: 43–77 points) and 51.4 points (range: 25–80 points), respectively and the average postoperative scores were 89.7 points (range: 64–100 points) and 79.7 points (range: 40–100 points), respectively. The average preoperative KSS and KSFS in the manual group were 50.7 points (range: 43–77 points) and 50.3 points (range: 10–80 points), respectively, and the average postoperative scores were 89.6 points (range: 70–100 points) and 75.2 (range: 5–100 points), respectively. No significant differences were noted between the two groups both pre-and postoperatively. The average preoperative range of motion (ROM) in the navigation group was 105.0° (75°–125°); −8.6° (range: 0° to −25°) for extension and 113.6° (range: 85°–135°) for flexion, respectively. The average postoperative ROM was 113.8° (85°–130°); −1.0° (range: 0° to −10°) for extension and 117.0° (range: 105°–130°) for flexion, respectively. The average preoperative ROM in the manual group was 102.5° (65°–140°); −10.2° (range: 0° to −25°) for extension and 112.7° (range: 75°–140°) for flexion, respectively, the average postoperative ROM was 106.9° (80°–130°); −0.0° (range: 0°) for extension and 106.9° (range: 80°–130°) for flexion, respectively. Although no significant difference was found between preoperative ROM for the two groups, the navigation group showed a significantly better ROM compared to the manual group.

Conclusions: Minimum 5-year follow-up of computer-assisted TKA used in the present study revealed that better ROM was achieved, compared with the conventional surgical method. KSS and KSFS were equally good among these two groups. The results focused on the radiographically malaligned patients and further longer follow-up were needed to reveal whether computer-assisted TKA has true clinical benefits compared with the conventional surgical method.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 448 - 448
1 Nov 2011
Sasaki K Kubo S Matsumoto T Ishida K Tei K Matsushita T Kurosaka M Kuroda R
Full Access

Purpose: Continuous femoral nerve block (CFNB) has been revealed to be a safe and effective method to decrease postoperative pain after total knee arthroplasty (TKA).

However, optimal duration for CFNB to decrease pain and accelerate rehabilitation program after TKA has not been addressed. We, therefore, compared three groups of patients which had different duration of CFNB (0, 2, and 5days) in this study.

Methods: Sixty patients who received primary TKA for osteoarthritis were divided into three groups based on the duration to receive CFNB for 0day, 2days or 5days (twenty patients for each group). Ropivacaine 2mg/mL was given through the femoral nerve catheter using elastomeric infusers (delivering 2ml/hr for each group).

Outcomes including visual analog scale (VAS) pain scores and range of motion (ROM) were compared at 1st, 3rd, 6th, 14th and 21th days after surgery. In addition, the postoperative date when patients could walk stably with parallel bar, walker, or T-cane were recorded and compared.

Results: At 1st and 3rd day postoperatively, the VAS was significantly better in the CFNB 2 days and CFNB 5 days group than in the CFNB 0 day group (P< 0.05).

ROM did not show significant difference among the three groups over postoperative days 1st to 21st (P> 0.05), although groups with the CFNB showed greater ROM at all time points. The CFNB 5 days group obtained stable walking ability with T-cane earlier than other groups (P< 0.05). No patient had any side effect by having CFNB in this study.

Discussion: Postoperative use of CFNB reduced pain at first 3days, and shorten the time to acquire stable walking ability after TKA. We conclude that CFNB should be kept for 5days after surgery to decrease pain and accelerate rehabilitation program after TKA.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 475 - 480
1 Apr 2009
Matsumoto T Kuroda R Kubo S Muratsu H Mizuno K Kurosaka M

We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0°, 10°, 45°, 90° and 135° of flexion, with the patella both everted and reduced.

While the measurement of the joint gap with a reduced patella in posterior-stabilised knees increased from extension to flexion, it remained constant for cruciate-retaining joints throughout a full range of movement. The joint gaps at deep knee flexion were significantly smaller for both types of prosthetic knee when the patellofemoral joint was reduced (p < 0.05).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 264 - 270
1 Feb 2009
Hasegawa T Miwa M Sakai Y Niikura T Kurosaka M Komori T

The haematoma occurring at the site of a fracture is known to play an important role in bone healing. We have recently shown the presence of progenitor cells in human fracture haematoma and demonstrated that they have the capacity for multilineage mesenchymal differentiation. There have been many studies which have shown that low-intensity pulsed ultrasound (LIPUS) stimulates the differentiation of a variety of cells, but none has investigated the effects of LIPUS on cells derived from human fracture tissue including human fracture haematoma-derived progenitor cells (HCs). In this in vitro study, we investigated the effects of LIPUS on the osteogenic activity of HCs. Alkaline phosphatase activity, osteocalcin secretion, the expression of osteoblast-related genes and the mineralisation of HCs were shown to be significantly higher when LIPUS had been applied but without a change in the proliferation of the HCs. These findings provide evidence in favour of the use of LIPUS in the treatment of fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 258 - 264
1 Feb 2007
Nagura I Fujioka H Kokubu T Makino T Sumi Y Kurosaka M

We developed a new porous scaffold made from a synthetic polymer, poly(DL-lactide-co-glycolide) (PLG), and evaluated its use in the repair of cartilage. Osteochondral defects made on the femoral trochlear of rabbits were treated by transplantation of the PLG scaffold, examined histologically and compared with an untreated control group.

Fibrous tissue was initially organised in an arcade array with poor cellularity at the articular surface of the scaffold. The tissue regenerated to cartilage at the articular surface. In the subchondral area, new bone formed and the scaffold was absorbed. The histological scores were significantly higher in the defects treated by the scaffold than in the control group (p < 0.05).

Our findings suggest that in an animal model the new porous PLG scaffold is effective for repairing full-thickness osteochondral defects without cultured cells and growth factors.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 133 - 138
1 Jan 2007
Oe K Miwa M Sakai Y Lee SY Kuroda R Kurosaka M

We isolated multilineage mesenchymal progenitor cells from haematomas collected from fracture sites. After the haematoma was manually removed from the fracture site it was cut into strips and cultured. Homogenous fibroblastic adherent cells were obtained. Flow cytometry revealed that the adherent cells were consistently positive for mesenchymal stem-cell-related markers CD29, CD44, CD105 and CD166, and were negative for the haemopoietic markers CD14, CD34, CD45 and CD133 similar to bone-marrow-derived mesenchymal stem cells. In the presence of lineage-specific induction factors the adherent cells could differentiate in vitro into osteogenic, chondrogenic and adipogenic cells.

Our results indicate that haematomas found at a fracture site contain multilineage mesenchymal progenitor cells and play an important role in bone healing. Our findings imply that to enhance healing the haematoma should not be removed from the fracture site during osteosynthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 129 - 133
1 Jan 2006
Lee SY Miwa M Sakai Y Kuroda R Niikura T Kurosaka M

We have investigated whether cells derived from haemarthrosis caused by injury to the anterior cruciate ligament could differentiate into the osteoblast lineage in vitro. Haemarthroses associated with anterior cruciate ligament injuries were aspirated and cultured. After treatment with β-glycerophosphate, ascorbic acid and dexamethasone or 1,25 (OH)2D3, a significant increase in the activity of alkaline phosphatase was observed. Matrix mineralisation was demonstrated after 28 days and mRNA levels in osteoblast-related genes were enhanced.

Our results suggest that the haemarthrosis induced by injury to the anterior cruciate ligament contains osteoprogenitor cells and is a potential alternative source for cell-based treatment in such injury.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 422 - 422
1 Apr 2004
Kurosaka M Komistek R Northcut E Dennis D Anderson D
Full Access

Introduction: Previous in vivo kinematic studies have assessed total knee arthroplasty (TKA) motion under weight-bearing conditions. This in vivo study analyzed and compared posterior cruciate retaining (PCR) and posterior stabilized (PS) kinematics under passive and weight-bearing conditions in subjects implanted with both a PCR and PS TKA.

Methods: Eighteen subjects were implanted with a PCR and a PS TKA, by a single surgeon using a similar surgical technique. Both implant designs had similar condylar geometry. Femorotibial contact positions for all 18 subjects (PCR and PS), implanted by a single surgeon, were analyzed using video fluoroscopy. Each subject,while under fluoroscopic surveillance, performed a weight-bearing deep knee bend and a passive, nonweight-bearing flexion. Video images were downloaded to a workstation computer and analyzed at varying degrees of knee flexion. Femorotibial contact paths for the medial and lateral condyles, axial rotation and femoral condylar lift-off were then determined using a computer automated model-fitting technique. Femorotibial contact anterior to the tibial midline in the sagittal plane was denoted as positive and contact posterior was denoted as negative.

Results: Under passive and weight-bearing conditions, the PCR TKA experienced more paradoxical anterior translation than the PS TKA. Under passive, non weight-bearing conditions, the PS TKA, on average, experienced 3.5 mm of posterior femoral rollback, compared to only 0.6 mm for the PCR TKA. Under weight-bearing conditions, the PS TKA experienced only 0.6 mm of posterior femoral rollback, compared to 0.9 mm for the PCR TKA. The maximum anterior slide was 10.0 mm for the PCR TKA and only 2.7 mm for the PS TKA. There was greater variability in both the PCR and PS anteroposterior data. Subjects having a PCR TKA experienced more normal axial rotation patterns. Sixteen of 18 PCR TKA experienced a normal axial rotation pattern under weight-bearing conditions, while only 9/18 PS TKA experienced a normal pattern. Nonweight-bearing, passive axial rotation patterns were more abnormal for both groups than the weight-bearing patterns. The greatest difference between passive and weight-bearing conditions occurred in the condylar lift-off data. Under passive conditions, both TKA groups experienced significantly greater magnitude and incidence of condylar lift-off. The maximum amount of condylar lift-off under passive conditions was 5.0 mm for the PCR TKA and 6.4 mm for the PS TKA.

Discussion: This is the first in vivo kinematic study to assess a comparison between PCR and PS TKA implanted by the same surgeon in the same patient. Subjects in this study experienced more abnormal kinematic patterns, especially condylar lift-off, when tested under passive, nonweight-bearing conditions. Subjects having a PS TKA experienced less variability in their kinematic data, but PCR TKA, on average, experienced more normal axial rotation and less condylar lift-off.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 115 - 118
1 Jan 2004
Miyamoto H Sumi M Kataoka O Doita M Kurosaka M Yoshiya S

We describe a patient with a traumatic spondylolisthesis of L5 and multiple, bilateral pedicle fractures from L2 to L5. Conservative treatment was chosen, with eventual neurological recovery and bony union. We are not aware of previous reports of this pattern of injury.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 177 - 177
1 Jul 2002
Kurosaka M
Full Access

The French word debridement means the removal of the foreign matter or devitalised tissue from a lesion until surrounding healthy tissue is exposed. Arthroscopic techniques facilitated the removal of the intra-articular torn menisci, loose bodies, degenerated articular cartilage, and osteophytes. However, debridement procedure itself cannot induce tissue regeneration thus, the basic goal of the procedure is relief of pain. If pain can be relieved by non-surgical means very few patients can be considered for arthroscopic management. Debridement of early osteoarthritic knees can be carried out with a minimally invasive procedure with extremely low risk of infection and morbidity. However, it should be understood that this procedure is basically indicated for early degenerative knee disease with mechanical problems such as torn menisci or flap lesion of the cartilage.

The general principle is to resect and remove less tissue and preserve the anatomical structure as much as possible. For example in the case of a degenerated horizontal tear of the medial meniscus, the torn fragment can be left alone as long as the remaining segment is not unstable. Arthroscopic removal and shaving of the fibrillated articular cartilage can minimise and reduce crepitation and abnormal sensation of the patello-femoral and tibio-femoral joint but the articular cartilage will not regenerate by this procedure. The longer-term knee function will be better if the anatomical structure is preserved as much as possible.

With increasing awareness of the important functions of the meniscus and the improved understanding of the operative procedure, arthroscopic meniscal repair has become a widely accepted method of treatment for the symptomatic peripheral meniscal tears in the younger athletic population. However, in the patients with degenerative arthritis this procedure is rarely recommended due to the degenerative nature of the repaired meniscus itself.

Recent studies and publications have shown that articular cartilage defects in the younger population can be managed by cartilage cell transplantation, periosteal or perichondral graft, osteochondral autograft, and osteochondral allograft. Good results can be expected by these procedures as long as the cartilage defect is contained and the rest of the cartilage is healthy. Unfortunately, this is not the story for most of the degenerative knee problems thus, excellent results are expected to be limited by arthroscopic treatment.

Relatively large chondral defects with associated degenerative change can be managed by arthroscopic drilling, abrasion arthroplasty, and microfracture. Although cartilage regeneration by these techniques is not predictable and consistent, reasonable results can be obtained in the selective cases with controlled postoperative management. The patients should not be too old and 4 to 8 weeks postoperative non-weight-bearing is needed. Cases treated with this type of approach will be presented and discussed in this presentation.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 179 - 180
1 Jul 2002
Kurosaka M
Full Access

Currently available knee prostheses can provide 100 to 110° of knee flexion and this is generally good enough to ascend and descend stairs, arise from a chair, and perform most of the daily life activity. However, in certain situations like gardening, sitting on the flat floor and activities that require a squatting position, deep knee bends are required. In some countries, such as Japan, deep knee flexion is very important for the activity of daily life such as leading a life on a Tatami mattress and using a Japanese style toilet. There are several crucial factors, which influence postoperative knee flexion. Those are 1.) preoperative range of motion, 2.) surgical technique, 3.) prosthesis design, and 4.) postoperative rehabilitation.

If a patient has longstanding, poor, preoperative range of motion, then the extensor mechanism itself became stiff in addition to the periarticular fibrotic change of the soft tissue and severe destruction of the bony structure. In this circumstance, it is awfully difficult to obtain deep knee flexion with currently available prostheses and surgical techniques. This indicates that we cannot wait for the last minute to perform TKR if a patient desires to gain deep knee flexion after the surgery.

Surgical technique influences postoperative range of motion significantly. Anatomically the structures that get tight in knee flexion are the extensor mechanism and PCL. Thus, to obtain more flexion you should recess tight PCLs if you choose PCR type prostheses. Since the appropriate amount of PCL recession is not always easy, PCS type prostheses generally yield better flexion. To reduce tension of the extensor mechanism you should resect more patella than usual but this may cause postoperative patellar fracture. Or you can deepen the patellar groove by prosthesis modification but we should remember that both of these techniques will cause loss of the extensor lever arm and power. All posterior overhanging bone should be knocked out after trial reduction of a femoral prosthesis. Slightly flexed positioning of the femoral component and posteriorly tilted positioning of the tibial component can provide better flexion although too much of this positioning causes postoperative extension block.

Regarding the prosthesis design, PCS type prostheses can provide more predictable postoperative knee flexion. Other alternatives are a femoral component with a smaller AP dimension and deep patello-femoral groove. However, both of these will cause weaker extensor power. Posterior lip of the tibial polyethylene decreases the contact pressure in knee flexion but will prevent posterior roll back of the femur and can cause impingement in deep knee flexion. In the normal knee, extreme internal rotation of the tibia occurs in deep knee flexion and this rotation cannot be achieved by a currently available knee design. Mobile bearing prostheses may be needed to achieve better kinematics.

Aggressive postoperative rehabilitation is advised to prevent postoperative contracture of the soft tissue. Finally, although getting deep knee flexion is needed it should be remembered that ensuring postoperative stability and long-term survivorship should always be the most important goal for successful TKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 34 - 37
1 Jan 2002
Kurosaka M Yoshiya S Kuroda R Matsui N Yamamoto T Tanaka J

We undertook 114 arthroscopic meniscal repairs in 111 patients and subsequently carried out second-look arthroscopy to confirm meniscal healing at a mean of 13 months after repair. Stable healing at the repaired site was seen in 90. Of these, however, 13 had another arthroscopy later for a further tear. The mean period between the repair and the observation of a repeat tear was 48 months. Of the 13 patients, 11 had returned to high activity levels (International Knee Documentation Committee level I or II) after the repair.

An attempt should be made to preserve meniscal function by repairing tears, but even after arthroscopic confirmation of stable healing repaired menisci may tear again. The long-term rate of healing may not be as high as is currently reported. Second-look arthroscopy cannot predict late meniscal failure and may not be justified as a method of assessment for meniscal healing. Young patients engaged in arduous sporting activities should be reviewed regularly even after arthroscopic confirmation of healing.