header advert
Results 1 - 19 of 19
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims

To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia.

Methods

We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 760 - 767
1 Jul 2023
Tanaka S Fujii M Kawano S Ueno M Sonohata M Kitajima M Mawatari D Mawatari M

Aims

The aims of this study were to validate the Forgotten Joint Score-12 (FJS-12) in the postoperative evaluation of periacetabular osteotomy (PAO), identify factors associated with joint awareness after PAO, and determine the FJS-12 threshold for patient-acceptable symptom state (PASS).

Methods

Data from 686 patients (882 hips) with hip dysplasia who underwent transposition osteotomy of the acetabulum, a type of PAO, between 1998 and 2019 were reviewed. After screening the study included 442 patients (582 hips; response rate, 78%). Patients who completed a study questionnaire consisting of the visual analogue scale (VAS) for pain and satisfaction, FJS-12, and Hip disability and Osteoarthritis Outcome Score (HOOS) were included. The ceiling effects, internal consistency, convergent validity, and PASS thresholds of FJS-12 were investigated.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 767 - 774
1 Jul 2022
Nakashima Y Ishibashi S Kitamura K Yamate S Motomura G Hamai S Ikemura S Fujii M

Aims

Although periacetabular osteotomies are widely used for the treatment of symptomatic dysplastic hips, long-term surgical outcomes and patient-reported outcome measures (PROMs) are still unclear. Accordingly, we assessed hip survival and PROMs at 20 years after transpositional osteotomy of the acetabulum (TOA).

Methods

A total of 172 hips in 159 patients who underwent TOA were followed up at a mean of 21.02 years (16.6 to 24.6) postoperatively. Kaplan-Meier analysis was used to assess survivorship with an endpoint of total hip arthroplasty (THA). PROMs included the visual analogue scale (VAS) Satisfaction, VAS Pain, Oxford Hip Score (OHS), and Forgotten Joint Score-12 (FJS-12). Thresholds for favourable outcomes for OHS (≥ 42) and FJS-12 (≥ 51) were obtained using the receiver operating characteristic curve with VAS Satisfaction ≥ 50 and VAS Pain < 20 as anchors.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 52 - 52
1 Nov 2021
Nakashima Y Ishibashi S Kitamura K Yamate S Motomura G Hamai S Ikemura S Fujii M Yamaguchi R
Full Access

Although periacetabular osteotomies are widely used for the treatment of symptomatic acetabular dysplasia, the surgical outcomes after long term follow-up are still limited. Thus, we assessed hip survival and patient-reported outcomes (PROMs) at 20 years after the transposition osteotomy of acetabulum (TOA).

Among 260 hips in 238 patients treated with TOA, 172 hips in 160 patients were evaluated at average 20.8 years, excluding patients who died or lost to follow-up. Kaplan-Meier analysis was used to assess survivorship with an end-point of THA. PROMs were evaluated using the VAS satisfaction, VAS pain, Oxford hip score (OHS), and Forgotten joint score (FJS). The thresholds of favorable outcomes of FJS and OHS were obtained using the receiver-operating characteristic curve with VAS satisfaction ≥ 50 and VAS pain < 20 as anchors.

Thirty-three hips (19.2%) underwent THA at average 13.3 years after TOA. Kaplan-Meier analysis revealed hip survival rate at 20 years was 79.7%. Multivariate analysis showed the preoperative Tönnis grade significantly influenced hip survival. Survival rates with Tönnis grade 0, grade 1, and grade 2 were 93.3%, 86.7%, and 54.8% at 20 years, respectively. More than 60% of the patients showed favorable PROMs (VAS satisfaction ≥ 50, VAS pain < 20, OHS ≥ 42, FJS ≥ 51). Advanced Tönnis grade at the latest follow-up and higher BMI were significantly associated with unfavorable OHS, but not with other PROMs.

This study demonstrated the durability of TOA for hips with Tönnis grade 0–1 and favorable satisfaction in majority of the patients at 20 years after surgery. Current presence of advanced osteoarthritis is associated with the lower hip function (OHS), but not necessarily associated with subjective pain and satisfaction. Higher BMI also showed a negative impact on postoperative function.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 131 - 131
1 Apr 2019
Kijima H Tateda K Yamada S Nagoya S Fujii M Kosukegawa I Miyakoshi N Shimada Y
Full Access

Purpose

Various approaches have been reported for the total hip replacement (THR). In recent years, a muscle sparing approach with low postoperative muscle weakness and low dislocation risk has been frequently selected. However, such surgery has a learning curve. Thus, at the time of switching from the conventional approach to such approaches, invasion or infection risk may increase with the operation time extension. The purpose of this study is to clarify the change of invasiveness or latent infection rate with the change in approach in order to select the cases safely at the beginning of introducing a new approach in THR.

Methods

In facility A, THR was performed with Dall's approach (Dall), but 1 surgeon changed Dall to anterolateral modified Watson-Jones approach (OCM) and another surgeon changed Dall to direct anterior approach (DAA). In facility B, all 3 surgeons changed posterolateral (PL) approach to OCM. The subjects are 150 cases in total, including the each last 25 cases operated with the conventional approach and the each first 25 cases operated with a new approach (Dall to OCM: 25 + 25, Dall to DAA: 25 + 25, PL to OCM: 25 +25 cases). And, differences in operative time, intraoperative bleeding volume, postoperative hospital stay, and postoperative hemoglobin, white blood cell count, lymphocyte count, creatine kinase (CK), C-reactive protein (CRP) were investigated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 51 - 51
1 Apr 2018
Kamatsuki Y Furumatsu T Miyazawa S Fujii M Kodama Y Hino T Ozaki T
Full Access

Purpose

Injuries of the meniscal attachments can lead to meniscal extrusion. We hypothesized that the extent of lateral meniscal extrusion (LME) was associated with the severity of the lateral meniscus posterior root tear (LMPRT). This study aimed to evaluate the relationship between preoperative LME and arthroscopic findings of LMPRT in knees with anterior cruciate ligament (ACL) injury.

Methods

Thirty-four knees that had LMPRTs with concomitant ACL injuries on arthroscopy were evaluated. Patients were divided into two groups, partial and complete root tears, via arthroscopic findings at the time of ACL reconstruction. We retrospectively measured preoperative LMEs using magnetic resonance imaging (MRI). Statistical analysis was performed using the Mann-Whitney U-test and Chi-square test.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 16 - 16
1 May 2017
Furumatsu T Inoue H Miyazawa S Tanaka T Fujii M Ozaki T
Full Access

Background

Meniscus repair can restore the function of torn meniscus in anterior cruciate ligament (ACL)-reconstructed knees. However, few reports investigate the relationship between concurrent meniscus repair with ACL reconstruction and postoperative meniscal position. This study aimed to evaluate the size of the medial meniscus in patients who underwent ACL reconstruction and concomitant all-inside medial meniscus repair.

Methods

This study received the approval of our Institutional Review Board. Twenty patients underwent ACL reconstruction and concurrent medial meniscus repair of a peripheral longitudinal tear using the FasT-Fix meniscal repair device. Medial tibial plateau length (MTPL) and width (MTPW) were determined by radiographic images. We evaluated the Lysholm score, anteroposterior instability (difference in KT-2000 arthrometer measurement), meniscal healing, and magnetic resonance imaging (MRI)-based medial meniscal length (MML) and width (MMW). The healing status of repaired medial meniscus was assessed by 2nd-look arthroscopy.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 14 - 14
1 Apr 2017
Tanaka T Furumatsu T Miyazawa S Fujii M Inoue H Ozaki T
Full Access

Background

Hyaluronan (HA) promotes extracellular matrix (ECM) production and inhibits the activity of matrix degrading enzymes in chondrocytes. The meniscus is composed of the avascular inner and vascular outer regions. Inner meniscus cells have a chondrocytic phenotype compared with outer meniscus cells. In this study, we examined the effect of HA on chondrocytic gene expression in human meniscus cells.

Methods

Human meniscus cells were prepared from macroscopically intact lateral meniscus. Inner and outer meniscus cells were obtained from the inner and outer halves of the meniscus. The proliferative activity of meniscus cells was evaluated by WST-1 assay in the presence or absence of HA (MW = 600–1200 kDa; Seikagaku). Gene expression of SOX9, COL2A1, and COL1A1 was assessed by a quantitative real-time PCR analysis. The effect of HA on the gene expression and cellular proliferation was investigated under the treatment of interleukin (IL)-1α. Meniscal samples perforated by a 2-mm-diameter punch were maintained for 3 weeks in HA-supplemented media. Cultured meniscal samples were evaluated by histological analyses.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 117 - 117
1 Jan 2017
Suzuki M Miyakoshi N Kasukawa Y Nozaka K Tsuchie H Fujii M Sato C Masutani N Kawano T Shimada Y
Full Access

The superior analgesic effects of minodronate compared with other bisphosphonates has been previously reported. However, to our knowledge, there are no studies analyzing the analgesic effects of bisphosphonates on chronic pain. The purpose of the present study was to evaluate the analgesic effects of minodronate (MIN), alendronate (ALN), and pregabalin (PRG) on chronic pain caused by chronic constriction injury (CCI) of the sciatic nerve.

Four-week-old female Wister rats underwent ovariectomy. At 8 weeks old, the left sciatic nerve was ligated to induce the chronic pain model (CCI side), and sham surgery was performed on the right posterior limb as a CCI control (control side). The rats were divided into the following four groups: 1) MIN group, administered with minodronate (0.15 mg/kg/week) (n = 10); 2) ALN group, administered with alendronate (0.15 mg/kg/week) (n = 10); 3) PRG group, administered with pregabalin (10 mg/kg) (n = 9); and 4) Control group, administered with vehicle (n = 10). Treatments were administered subcutaneously every week for 2 weeks immediately after CCI. To quantify the sensitivity to a tactile stimulus, paw withdrawal in response to a tactile stimulus was measured using von Frey filaments at 0, 1, and 2 weeks after CCI. Von Frey filaments were applied to the plantar surface of the hindpaws for 3 s, and this was repeated three times. Paw withdrawal in response to the stimulus was evaluated by scoring as follows: 0, no response; 1, a slow and/ or slight response to the stimulus; 2, a quick withdrawal response; 3, an intense withdrawal response away from the stimulus. The mean value of the score was adopted as the pain score. After evaluating the response, bilateral femurs were harvested for bone mineral density (BMD) measurements.

The pain score of the CCI side was significantly higher than that of the sham side in all groups (p < 0.05) at each time point. The pain score for the MIN group, but not the ALN group, of the CCI side was significantly lower (p = 0.05) at 0 and 1 week after CCI. Total femoral BMD of the CCI side was significantly lower in the PRG and Control groups than those of the MIN and ALN groups (p < 0.05). No significant difference was identified for BMD between the MIN and ALN groups.

Minodronate showed a significant analgesic effect on chronic pain and suppressed osteoporotic changes caused by CCI.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 167 - 167
1 Jul 2014
Iwamoto K Tomita T Yamazaki T Sasaki A Kii Y Futai K Miyamoto T Fujii M Yoshikawa H Sugamoto K
Full Access

Summary

The effect of the geometry of the tibial polyethylene insert was investigated in vivo loaded conditions.

Introduction

The decision to choose CR (cruciate retaining) insert or CS (condylar stabilised) insert during TKA remains a controversial issue. Triathlon CS type has a condylar stabilised insert with an increased anterior lip that can be used in cases where the PCL is sacrificed but a PS insert is not used. The difference of the knee kinematics between CR and CS insert remains unclear. This study measured knee kinematics of deep knee flexion under load in two insert designs using 2D/3D registration technique.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 291 - 291
1 Mar 2013
Okada Y Abe N Miyazawa S Furumatsu T Fujii M Ozaki T
Full Access

Introduction

In Japan, edoxaban has been used for the prevention of venous thromboembolism (VTE) after total knee arthroplasty (TKA) since June 2011. Edoxaban is an oral direct factor Xa inhibitor, expected to be more convenient for the postoperative treatment of TKA. Enoxaparin, a II and Xa inhibitor, was approved in Japan for the prevention of VTE in patients undergoing orthopedics surgery from 2008. In this study, the effect for the prevention of VTE after TKA was compared between these two drugs in Japanese patients.

Patients and Methods

We studied 42 Japanese patients who underwent TKA from May 2011 to April 2012. The operations were performed under general anesthesia, continuous femoral nerve block, an air tourniquet, and using cements for implant fixation. These patients were divided in two groups, use of 30 mg edoxaban once daily (ED group), and use of 1000 IU of enoxaparin twice daily (EN group). The initial dose was administered between 12 and 21 hours after surgery. We compared the incidence of VTE, bleeding complications, D dimer levels, and hemoglobin (Hb) loss. The screening of VTE was performed by enhanced CT scan screening from the chest to the foot on postoperative day 5 or 6 in all patients. The bleeding complication was divided into major bleeding and minor bleeding with Japanese guideline for the prevention of VTE. D dimer levels and Hb levels were preoperatively and postoperative day 1, 3, 5, 7, and 14. The loss of Hb was calculated from preoperative Hb level minus lowest postoperative Hb level.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 329 - 329
1 Mar 2013
Shimizu N Tomita T Patil S Yamazaki T Iwamoto K Kurita M Fujii M Lima DD Sugamoto K
Full Access

Background

The decision to choose CR (cruciate retaining) insert or CS (condylar stabilized) insert during TKA remains a controversial issue. Triathlon CS type has a condylar stabilized insert with an increased anterior lip that can be used in cases where the PCL is sacrificed but a PS insert is not used. The difference of the knee kinematics remains unclear. This study measured knee kinematics of deep knee flexion under load in two insert designs using 2D/3D registration technique.

Materials and methods

Five fresh-frozen cadaver lower extremity specimens were surgically implanted with Triathlon CR components (Stryker Orthopedics, Mahwah, NJ). CR insert with retaining posterior cruciate ligament were measured firstly, and then CS insert after sacrificing posterior cruciate ligament were measured. Under fluoroscopic surveillance, the knees were mounted in a dynamic quadriceps-driven closed-kinetic chain knee simulator based on the Oxford knee rig design. The data of every 10° knee flexion between 0° and 140° were corrected. Femorotibial motion including tibial polyethylene insert were analyzed using 2D/3D registration technique, which uses computer-assisted design (CAD) models to reproduce the spatial position of the femoral, tibial components from single-view fluoroscopic images. We evaluated the knee flexion angle, femoral axial rotation, and anteroposterior translation of contact points.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 173 - 173
1 Mar 2013
Fujii M Abe N Furumatsu T Miyazawa S Okada Y Ozaki T
Full Access

Purpose

Computer navigation system has been reported as a useful tool to obtain the proper alignment of lower leg and precise implantation in TKA. This system alsoãζζhas shown the accurate gap balancing which was lead to implants longevity and optimal knee function. The aim of this study was determine that the postoperative acquired deep knee flexion would be influenced by intraoperative kinematics on navigated TKA even under anesthesia.

Materials & methods

Forty knees from 40 patients, who underwent primary TKA (P.F.C. sigma RPF, DePuy Orhopaedic International, Leed, UK) with computer-navigation system (Ci Knee, BrainLAB / DePuy Inc, Leeds, UK), were recruited in this study. These patients were classified into two groups according to the recorded value of maximum knee flexion at three month after surgery: 15 patients who obtained more than 130 degrees of flexion in Group A, and 25 patients less than 130 degrees in Group B. We retrospectively reviewed about intraoperative kinematics in each group, to obtain the clue for post operative deep-flexion. The measurements of intraoperative kinematics were consisted of 3 points: femoral rotation angle (degree) and antero-posterior translation (mm), which were measured as the translation of the lowest points of femoral component to tibial cutting surface, and the joint gap difference between the medial and lateral components gap (mm). All joint kinematic data were recorded at every 10 degrees of flexion from maximum extension to flexion under anesthesia.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 123 - 123
1 Jun 2012
Kurita M Tomita T Fujii M Yamazaki T Kunugiza Y Futai K Kawashima K Shimizu N Sugamoto K
Full Access

Background

Mobile-bearing (MB) total knee prostheses have been developed to achieve lower contact stress and higher conformity compared to fixed-bearing total knee prostheses. However, little is known about the in vivo kinematics of MB prostheses especially about the kinematics of polyethylene insert (PE). In vivo motion of PE during squatting still remains unclear. The objective of this study is to investigate the in vivo motion of MB total knee arthroplasty including PE during squatting.

Patients and methods

We investigated the in vivo knee kinematics of 11 knees (10 patients) implanted with Vanguard Rotationg Platform High Flex (Biomet(r)). Under fluoroscopic surveillance, each patient did a wight-bearing deep knee bending motion. Motion between each component was analyzed using two- to three-dimensional registration technique, which uses computer-assisted design (CAD) models to reproduce the spatial position of the femoral, tibial components, and PE (implanted with five tantalum beads intra-operatively) from single-view fluoroscopic images. We evaluated the range of motion between the femoral and tibial components, axial rotation between the femoral component and PE, the femoral and tibial component, and the PE and tibial component, and AP translation of the nearest point between the femoral and tibial component and between the femoral component and PE.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 235 - 235
1 Jun 2012
Takahira N Uchiyama K Fukushima K Kawamura T Ashihara M Fujii M Kihara Y Yoshimoto M Kitagawa J
Full Access

The purpose of this study is to prove whether Japanese patients undergoing primary total hip arthroplasty (THA) for the hip dysplasia were able to return to sport after surgery.

A questionnaire survey was completed by 77 patients in 9 males and 68 females between 1 and 3 years after surgery. Mean age at surgery was 66.1 (range, 49 to 87).

In the 3 years before surgery 40 (51.9%) patients were participating in sport. By 1 to 3 years after surgery 43 (55.8%) patients were participating in sport. A total of 33 (82.5%) had returned to their sporting activities by 1 to 3 years after surgery in groups who played sports before surgery and 7 (17.5%) were unable to do with the most common reason being “cannot move as much as I wanted”. On the other hand, a total of 10 (27%) had started playing sports after surgery. The sports activities after surgery were the most common being walking, radio calisthenics, and swimming as low-impact sports. A total of 27 (73%) did not play sports before or after surgery with the most common reason being “fear of damage to the hip joint”.

In conclusion, when Japanese patients who have undergone THA for hip dysplasia choose to participate in sports, orthopedic surgeons should provide information with which to evaluate the risk of sports activity and recommend appropriate sports activity.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1449 - 1456
1 Nov 2011
Fujii M Nakashima Y Yamamoto T Mawatari T Motomura G Iwamoto Y Noguchi Y

In order to clarify how intra-articular lesions influence the survival of a periacetabular osteotomy in patients with dysplasia of the hip, we performed an observational study of 121 patients (121 hips) who underwent a transposition osteotomy of the acetabulum combined with an arthroscopy. Their mean age was 40.2 years (13 to 64) and the mean follow-up was 9.9 years (2 to 18). Labral and cartilage degeneration tended to originate from the anterosuperior part of the acetabulum, followed by the femoral side. In all, eight hips (6.6%) had post-operative progression to Kellgren–Lawrence grade 4 changes, and these hips were associated with the following factors: moderate osteoarthritis, decreased width of the joint space, joint incongruity, and advanced intra-articular lesions (subchondral bone exposure in the cartilage and a full-thickness labral tear). Multivariate analysis indicated subchondral bone exposure on the femoral head as an independent risk factor for progression of osteoarthritis (p = 0.003). In hips with early stage osteoarthritis, femoral subchondral bone exposure was a risk factor for progression of the grade of osteoarthritis.

Although the outcome of transposition osteotomy of the acetabulum was satisfactory, post-operative progression of osteoarthritis occurred at a high rate in hips with advanced intra-articular lesions, particularly in those where the degenerative process had reached the point of femoral subchondral bone exposure.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 141 - 141
1 Mar 2010
Matsushita A Nakashima Y Yamamoto T Mawatari T Motomura G Fujii M Iwamoto Y
Full Access

Combined anteversion (CA) is defined as the sum of the anteversions of acetabular and femoral components. In this study, we determined the appropriate CA in a variety of femoral versions using a total hip arthroplasty model. In addition, we also examined the usefulness of a changeable neck to improve range of hip motion in these cases.

Using a THA model, the range of motion (ROM) was tested in various CA values obtained by changing the anteversion of a cup in six increments after setting the femoral anteversion to 20° or 60° anteversion and 20° retroversion. The angle of the changeable neck was changed in 11 increments of 5°. To evaluate stability, the range of internal rotation at 90° flexion, the external rotation at 0° extension, and the range flexion was measured when any impingement occurred prior to dislocation. We defined the required ROM that met 40° internal rotation, 30° external rotation, and 110° flexion.

In normal 20° anteversion group, the required ROM was achieved with CA between 30° and 50° without using any changeable necks. In excessive anteversion 60° group, the range of external rotation was less than 10° even when the acetabular component was set 10° retroverted, because of the bone impingement between the greater trochanter and the posterior acetabulum. When 25° retroverted changeable neck was used, ROM improved to 30° external rotation and satisfied the required ROM. In 20° retroversion group, the internal rotation angle was 31° even when the acetabular component was opened 35° anteverted, because of anterior neck-liner impingement. When 25° anteverted changeable neck was used, ROM improved to 39° internal rotation and 130° flexion.

In cases with normal anteversions, the required ROM can be achived by adjusting CA. In cases with excessive anteversion or retroversion, there was a limitation of the CA adjustment. The use of changeable necks allows for further improvement of ROM by compensating femoral anteversions.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 189 - 189
1 Mar 2008
Watanabe T Tomita T Yamazaki T Fujii M Sugamoto K Yoshikawa H
Full Access

The current study aimed to analyze in vivo kinematics during deep knee bending motion by subjects with fully congruent designed mobile-bearing total knee arthroplasty (TKA) allowing axial rotation and anterior/posterior (AP) gliding.

Twelve subjects were implanted with Dual Bearing-Knee (DBK, slot type: Finsbury, UK) prostheses. These implants include a mobile-bearing insert that is fully congruent with the femoral component throughout flex-ion and allows axial rotation and a 4–6 mm limited AP translation. Sequential fluoroscopic images were taken in the sagittal plane during loaded knee bending motion. In vivo kinematics of knee prostheses were computed accurately using a 2D/3D registration technique, which uses computer-assisted design models to reproduce the spatial position of metallic femoral and tibial components from calibrated single-view fluoroscopic images.

The average femoral component demonstrated 13.4° external axial rotation for 0° to 120° flexion. On average, the medial condyle moved anteriorly 6.2 mm for 0° to 100° flexion, then posteriorly 4.0 mm for 100° to 120° flexion. On average, the lateral condyle moved anteriorly 1.0 mm for0° to 40° flexion, then posteriorly 8.7 mm for 40° to 120° flexion. The average subject experienced a lateral pivot pattern from −5° to 60° flexion, a central pivot pattern from 60° to 100° flexion, and a rollback pattern which bilateral condyles moved backward from 100° to 120° of knee flexion.

Subjects with DBK mobile-bearing TKA in some-degree reproduced femoral external rotation during increasing knee flexion and bicondylar posterior rollback during terminal flexion, due to surrounding soft tissue structures. The geometry of replaced articular surfaces and mobility of the mobile-bearing insert produced lateral-to-central pivoting motions during the flexion cycle, a phenomenon not typically observed in normal knees. Using the current technique, we characterized the unique kinematics of fully congruent designed DBK mobile-bearing knee prostheses.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 209 - 209
1 May 2006
Kuriyama K Hashimoto J Fujii M Murase T Tsuboi H Myoui A Yoshikawa H
Full Access

Background: Juxta-articular intraosseous cystic lesions (JAICL) are common lesion in patients with rheumatoid arthritis (RA) and could cause spontaneous pathological fractures and extensive joint destruction. Although surgical treatment is well indicated for benign bone tumour such as solitary bone cyst, RA induced JAICL have been rarely treated surgically because of following reasons. The first is the possible re-absorption of grafted bone due to disease progression. The second is donor site problem of iliac bone autografting. The third is limitation of autograft for possible operations in the future. The fourth is the lack of bone graft substitutes with good osteoconductivity. We have developed the interconnected porous calcium hydroxyapatite ceramic (IP-CHA) with excellent osteoconductivity. The IP-CHA achieved major incorporation with host bone much more rapid than the other porous calcium hydroxyapatite ceramics. We evaluated the feasibility and effectiveness of curettage and packing with the IP-CHA for the treatment of JAICL in RA patients.

Methods: Nine JAICL in 7 RA patients were treated by curettage and packing with IP-CHA. Eight lesions were impending pathological fractures. Two were male and five were female, the average age of operation was 57.8 years (range, forty-nine to seventy-two years). Follow-up assessment was based on final radiography at an average of 10.9 months after surgery (range, five to seventeen months). The expansion of the cystic lesions around the implanted IP-CHA and the re-absorption of the IP-CHA itself, which means erosion or increasing porosity of implanted IP-CHA, were assessed on the basis of the radiographies at just after operation and final follow up.

Results: The locations were as follows: distal radius, 6 lesions; distal ulna, 1; proximal tibia, 1; distal fibula, 1. No lesions showed the re-absorption of implanted IP-CHA itself. One of 9 lesions showed out-expansion of radiolucent area around the implanted IP-CHA without re-absoption of IP-CHA itself at the final follow-up. There were no postoperative fractures as complication.

Conclusions: These results suggested that surgical intervention with the IP-CHA could be useful for prevention of pathological fractures due to arthritis related JAICL. The efficacies of this technique might be augmented by amelioration of disease activity with concomitant drug therapy including biologics, since there was one case with out-expansion of cystic lesions in RA patients.