header advert
Results 21 - 40 of 119
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 468 - 468
1 Dec 2013
Morison Z Olsen M Donnolly M Blankstein M Schemitsch E
Full Access

The purpose of this study was to examine the utility of the acetabular component introducer as a tool to intra-operatively predict implant inclination in total hip arthroplasty. This study investigated (1) the correlation between intra-operative photographic assessment of cup inclination using the acetabular introducer and that measured on post-operative radiograph; and (2) the accuracy of intra-operative prediction of abduction angle.

For this study, we prospectively recruited 56 patients scheduled to receive primary hip arthroplasty from one of two senior surgeons. During the procedure, the lead surgeon provided a prediction of the abduction angle based on the alignment of the impactor attached to the cup in its final seated position. A standardized anteroposterior (AP) photograph was then taken of the acetabular impactor in situ. Abduction angles were measured by two observers on the photographs and post-operative AP pelvis radiographs. Linear regression was used to determine the correlation between the angle of the guide measured on the photographs and the actual position of the implant measured on the radiograph. Descriptive statistics were further used to analyze the accuracy of the intra-operative prediction as compared with the abduction angle measured on the photographs.

Measurements of cup position made from post-operative radiographs were significantly correlated with the measurements as assessed by intra-operative photographs (r = 0.34, p = 0.00). Our findings demonstrate that radiological abduction angles tend to be greater than that assessed by intra-operative photographs by a mean of 5.6 degrees (SD = 6.6 degrees; 95% CI = 7.3 to 3.9 degrees). Conversely, surgeon prediction of cup inclination based on the acetabular introducer differed from the radiographic measurements by a mean of 6.8 degrees (SD = 8.7 degrees). There was good agreement between the two observers in both photographic and radiographic measurement (k = 0.95, k = 0.96, respectively).

In conclusion, we found that the intra-operative photographic assessment of acetabular cup inclination by acetabular impactor alignment tends to underestimate the abduction angle by a mean of approximately 5 degrees. In addition, intra-operative surgeon estimation of acetabular inclination did not appear accurate in this study demonstrating that cup position should rely on additional visual cues beyond that captured in the anteroposterior view of the cup introducer.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 466 - 466
1 Dec 2013
Olsen M Naudie D Edwards M Sellan M McCalden RW Schemitsch E
Full Access

Introduction:

Alignment of the initial femoral guidewire is critical in avoiding technical errors that may increase the risk of failure of the femoral component. A novel alternative to conventional instrumentation for femoral guidewire insertion is a computed tomography (CT) based alignment guide. The aim of this study was to assess the accuracy of femoral component alignment using a CT-based, patient specific femoral alignment guide.

Methods:

Between March 2010 and January 2011, 25 hip resurfacings utilizing a CT-based femoral alignment guide were performed by three surgeons experienced in hip resurfacing. Stem-shaft angle (SSA) accuracy was assessed using minimum 6 week post-operative digital radiographs. A benchside study was also conducted utilizing six pairs of cadaveric femora. Each pair was divided randomly between a group utilizing firstly a conventional lateral pin jig followed by computer navigation and a group utilizing a CT-based custom jig. Guidewire placement accuracy for each alignment method was assessed using AP and lateral radiographs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 467 - 467
1 Dec 2013
Morison Z Olsen M Mehra A Schemitsch E
Full Access

Purpose:

The use of computer navigation has been shown to improve the accuracy of femoral component placement compared to conventional instrumentation in hip resurfacing. Whether exposure to computer navigation improves accuracy when the procedure is subsequently performed with conventional instrumentation without navigation has not been explored. We examinedwhether femoral component alignment utilizing a conventional jig improves following experience with the use of imageless computer navigation for hip resurfacing.

Methods:

Between December 2004 and December 2008, 213 consecutive hip resurfacings were performed by a single surgeon. The first 17 (Cohort 1) and the last 9 (Cohort 2) hip resurfacings were performed using a conventional guidewire alignment jig. In 187 cases the femoral component was implanted using the imageless computer navigation. Cohorts 1 and 2 were compared for femoral component alignment accuracy.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 143 - 143
1 Dec 2013
Olsen M Lewis P Wolek R McKee M Waddell J Schemitsch E
Full Access

Introduction:

One method of femoral head preservation following avascular necrosis (AVN) is core decompression and Tantalum Rod insertion. There is, however, a published failure rate of up to 32% at 4 years. The purpose of the present study was to document the clinical and radiological outcome following Total Hip Arthroplasty (THA) subsequent to failed Tantalum Rod insertion.

Methods:

Twenty-five failed Tantalum Rod insertions subsequently requiring THA were identified from a prospectively updated database. Seventeen patients met minimum 2 year clinical and radiographic follow-up criteria. St. Michael's Hip (SMH) scores were compared to a matched cohort of patients with THA for AVN without prior Tantalum Rod insertion. Postoperative radiographs were reviewed assessing component alignment, linear wear (Dorr & Wan) and presence of tantalum residue within the joint space.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 11 - 11
1 Apr 2013
Hoang-Kim A Beaton D Kulkarni AV Bhandari M Schemitsch E
Full Access

Introduction

There has been a paradigm shift in orthopaedic research, it is now recognized that the extent to which interventions really make a difference to a patient's overall life is indicated by measuring one's general health status. The primary aim of this study was to report how the methodology of current evidence in hip fracture research can improve if studies included patients with cognitive impairment.

Materials and methods

Using multiple databases inclusive from 1990 to May 2009, we performed a systematic review of all hip fracture observational cohorts and randomized studies (RCTs).


The Study to Prospectively Evaluate Reamed Intramedullary Nails in Tibial Shaft Fractures (SPRINT) randomised 1,226 patients treated by intramedullary nailing to reamed versus unreamed groups. We aimed to determine if there was a difference in the number of patients requiring more than one reoperation between the groups.

We hypothesised there would be differences in the number of patients with more than one reoperation in the reamed versus unreamed groups and in patients with open fractures versus closed fractures.

We identified patients requiring more than one reoperation during the 12 m follow-up. We considered those that were reamed versus unreamed, open versus closed, and those with a reoperation planned post 12 m follow-up. We also compared patient and fracture characteristics.

We identified a total of 44 patients requiring two or more reoperations. No difference between the reamed and unreamed groups was found in the risk of having more than one reoperation. Patients with two or more reoperations were older (p=0.03), had a higher frequency of open fractures (p<0.001), and had higher energy mechanisms of injury (p<0.001). The first reoperation was in response to infection for 25 patients. 12 patients had additional reoperations planned after the 12 m follow-up.

A relatively small number of tibial shaft fracture patients required more than one reoperation. Further study is required to assess consequences of needing multiple reoperations in this high risk group.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 17 - 17
1 Apr 2013
Giles E Nauth A Lin T Glick M Schemitsch E
Full Access

Introduction

Nonunion is a common and costly fracture outcome. Intricate reciprocity between angiogenesis and osteogenesis means vascular cell-based therapy offers a novel approach to stimulating bone regeneration.

Hypothesis

The current study compared early and late outgrowth endothelial progenitor cell subtypes (EPCs vs OECs) for fracture healing potential in vitro and in vivo.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 68 - 68
1 Jan 2013
Pagkalos J Davis E Gallie P Macgroarty K Waddell J Schemitsch E
Full Access

Implant alignment in knee arthroplasty has been identified as critical factor for a successful outcome. Human error during the registration process for imageless computer navigation knee arthroplasty directly affects component alignment. This cadaveric study aims to define the error in the registration of the landmarks and the resulting error in component alignment.

Five fresh frozen cadaveric limbs including the hemipelvis were used for the study. Five surgeons performed the registration process via a medial parapatellar approach five times. In order to identify the gold standard point, the soft tissues were stripped and the registration was repeated by the senior author. Errors are presented as mm or degrees from the gold standard registration.

The error range in the registration of the femoral centre in the coronal plane was 6.5mm laterally to 5.0mm medially (mean: −0.1, SD: 2.7). This resulted in a mechanical axis error of 5.2 degrees valgus to 2.9 degrees varus (mean: 0.1, SD: 1.1). In the sagittal plane this error was between −1.8 degrees (extension) and 2.7 degrees (flexion). The error in the calculation of the tibial mechanical axis ranged from −1.0 (valgus) to 2.3 (varus) degrees in the coronal plane and −3.2 degrees of extension to 1.3 degrees of flexion. Finally the error in calculating the transepicondylar axis was −11.2 to 6.3 degrees of internal rotation (mean: −3.2, SD: 3.9).

The error in the registration process of the anatomical landmarks can result in significant malalignment of the components. The error range for the mechanical axis of the femur alone can exceed the 3 degree margin that has been previously been associated with implant longevity. The technique during the registration process is of paramount importance for image free computer navigation. Future research should be directed towards simplifying this process and minimizing the effect of human error.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 202 - 202
1 Sep 2012
Van Der Weegen W Hoekstra H Sijbesma T Bos E Schemitsch E Poolman R
Full Access

Introduction

Hip resurfacing arthroplasty (HRA) has seen a recent revival with third generation Metal-on-Metal prostheses and is now widely in use. However, safety and effectiveness of hip resurfacing are still questioned. We systematically reviewed peer-reviewed literature on hip resurfacing arthroplasty to evaluate implant survival and functional outcomes of hybrid Metal-on-Metal hip resurfacing Arthroplasty.

Method

Electronic databases and reference lists were searched from 1988 to September 2009. Identified abstracts were checked for inclusion or exclusion by two independent reviewers. Data were extracted and summarized by one reviewer and verified by a second reviewer. Main study endpoint was implant survival, which we compared with the National Institute of Clinical Excellence (NICE) benchmark. We also evaluated radiological and functional outcomes, failure modes and other adverse events.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 152 - 152
1 Sep 2012
Van Der Weegen W Hoekstra H Sybesma T Bos E Schemitsch E Poolman R
Full Access

Background

Hip resurfacing arthroplasty (HRA) has seen a recent revival with third generation Metal-on-Metal prostheses and is now widely in use. However, safety and effectiveness of hip resurfacing are still questioned. We systematically reviewed peer-reviewed literature on hip resurfacing arthroplasty to address these issues.

Objective

To evaluate implant survival and functional outcomes of hybrid Metal-on-Metal hip resurfacing arthroplasty (HRA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 142 - 142
1 Sep 2012
Edwards M Lutz M Keast-Butler O Escott B Schemitsch E Waddell J
Full Access

To review prospectively collected data on patients undergoing primary total hip arthroplasty utilizing two different cementless acetabular components.

All patients undergoing primary total hip replacement surgery at our institution are entered prospectively into a database which includes history and physical examination, radiology, WOMAC and SF-36 scores. The patients are re-examined, re-x-rayed and re-scored at 3 months, 6 months and 1 year after surgery and yearly thereafter.

Using this database we are able to identify patients who have undergone total hip replacement using one of two geometric variants of the acetabular component. The first design is hemispherical and the second design has a peripheral rim expansion designed to increase initial press-fit stability.

Five hundred and twenty-seven consecutive primary total hip replacements were identified using either of the geometric variants of the acetabular component. Results at a mean of 7 years revealed a 95.6% survivorship with no significant difference between the two component designs with revision for aseptic loosening as the end point. Functional scores between the two groups of patients also demonstrated no statistically significant difference.

Radiologic assessment, however, showed a difference between the two designs. The hemispherical design which matches the reamer line-to-line had 80% complete osseointegration on final radiologic review while the second design with a peripheral rim expansion had only 57% complete osseointegration. This was statistically significant. The peripherally expanded components also had a greater number of screws inserted at the time of surgery, felt by us to be a reflection of initial surgeon dissatisfaction with component stability at the time of insertion of the component.

The difference in screw numbers was also statistically significant. This study demonstrates that a hemispherical design with line-to-line contact between the acetabular component surface and the acetabular bone is statistically superior in terms of bone ingrowth and probably statistically superior in terms of initial press-fit stability when compared to a peripherally expanded component.

Peripherally expanded components appear to offer no advantage over hemispherical components in terms of clinical outcome and are statistically inferior to hemispherical components in radiologic parameters at 7 years follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 110 - 110
1 Sep 2012
Nikolaou V Edwards M Bogoch E Schemitsch E Waddell J
Full Access

This prospective randomised controlled trial aims to compare the clinical and radiological outcomes of ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces at a minimum of five years.

One hundred and two primary total hip replacements were performed in ninety one patients between February 2003 and March 2005. All patients were younger than 65 (mean 52.7, 19–64). They were randomised to receive one of the three bearing surfaces. All patients had 28mm articulations with a Reflection uncemented acetabular component and a Synergy stem (Smith & Nephew, Memphis, Tennessee). Patients were followed up periodically up to at least sixty months following surgery. Outcome measures included WOMAC and SF12 scores. Radiological assessment included implant position, evidence of osteolysis and measurement of linear wear.

Ninety seven hip replacements in eighty seven patients were available for review at a minimum of five years. Two hips were revised (one for infection and one for periprosthetic fracture), leaving a total of ninety four hips available for final review. There were no differences in age, gender, body mass index, diagnosis, level of activity, and co-morbidities between the three groups. At a minimum of five years there were no statistical differences in the clinical outcomes using the WOMAC or SF12 scores. Three patients in the ceramic group reported squeaking. Radiological evaluation revealed mean annual wear rates in the ceramic group of 0.006mm/yr, standard polyethylene of 0.151mm/yr and highly cross linked polyethylene of 0.059mm/yr. ANOVA analysis revealed these differences in wear rates to be significant (p<0.0001).

In the mid term there are no differences in clinical outcome between ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces in total hip arthroplasty. Ultra high molecular weight polyethylene has a significantly greater annual linear wear rate than highly cross-linked polyethylene.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 172 - 172
1 Jun 2012
Waddell J Edwards M Lutz M Keast-Butler O Escott B Schemitsch E Nikolaou V
Full Access

Purpose

To review prospectively collected data on patients undergoing primary total hip arthroplasty utilizing two different cementless acetabular components.

Materials & Methods

All patients undergoing primary total hip replacement surgery at our institution are entered prospectively into a database which includes history and physical examination, radiology, WOMAC and SF-36 scores. The patients are re-examined, re-x-rayed and re-scored at 3 months, 6 months and 1 year after surgery and yearly thereafter.

Using this database we are able to identify patients who have undergone total hip replacement using one of two geometric variants of the acetabular component. The first design is hemispherical and the second design has a peripheral rim expansion designed to increase initial press-fit stability.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 6 - 6
1 Jun 2012
Waddell J Baird R Nikolaou V Schemitsch E
Full Access

To review prospectively collected data on patients undergoing femoral revision arthroplasty for failed cemented or cementless primary stems.

Materials & Methods

All patients undergoing primary and revision joint replacement surgery at our institution are prospectively entered into a database which includes history and physical examination, radiology, WOMAC and SF-36 scores. These investigations are repeated 3 months, 6 months, 1 year and yearly thereafter at each patient visit.

This database identified all patients undergoing femoral revision arthroplasty over the last 10 years.

Results

There were a total of 231 patients with 248 revision procedures performed. There were 127 female and 104 male patients and the mean age at the time of revision surgery was 69.4 years. Twenty-two of these patients had had at least one prior revision operation on the index hip. Thirty hips were treated with a cemented Echelon stem and 218 treated with a cementless Echelon stem. Of the 248 hips 14 patients were lost to follow-up (14 hips) and 9 patients (9 hips) are deceased. The average follow-up was 5.9 years.

Of the 225 hips remaining in the follow-up series there was a single case of aseptic loosening confirmed radiologically. Twenty-one hips were diagnosed with infection (9.3%); 6 of those patients had had at least one prior revision procedure and 4 additional patients had a prior diagnosis of infection. Therefore, 10 of the 21 hips were either definitely or probably infected at the time of their revision operation on which we are reporting. Nine patients (4%) had multiple dislocations post-operatively. These were patients who had undergone multiple revisions or whose primary revision operation was for instability. An additional 18 patients (8%) had a single dislocation treated by closed reduction requiring no further treatment.

There were 6 hips with intra-operative fracture requiring immediate re-revision plus fracture fixation and a further 12 hips (5.3%) who sustained a peri-prosthetic fracture some time after their revision procedure.

Despite the number of complications the majority of patients required no further surgical treatment. Eleven hips (4.8%) required re-revision of the femoral component. Therefore the overall survival rate at 5.9 years of the Echelon revision stem was 95.2%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 173 - 173
1 Jun 2012
Waddell J Nikolaou V Edwards M Bogoch E Schemitsch E
Full Access

Aim

This prospective randomised controlled trial aims to compare the clinical and radiological outcomes of ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces at a minimum of five years.

Methods

One hundred and two primary total hip replacements were performed in ninety one patients between February 2003 and March 2005. All patients were younger than 65 (mean 52.7, 19-64). They were randomised to receive one of the three bearing surfaces. All patients had 28mm articulations with a Reflection uncemented acetabular component and a Synergy stem (Smith & Nephew, Memphis, Tennessee). Patients were followed up periodically up to at least sixty months following surgery. Outcome measures included WOMAC and SF12 scores. Radiological assessment included implant position, evidence of osteolysis and measurement of linear wear.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 99 - 99
1 May 2012
Higgins G Tunggal J Schemitsch E Waddell J
Full Access

We designed this study to determine the clinical evidence to support use of the five degree tibial extra-medullary cutting block over the zero degree cutting block.

We identified three groups of patients from the databases and clinical notes at St Michaels Hospital, Toronto. Group one were primary total knees performed using the five degree cutting block, group two were primary total knees performed using the zero degree cutting block and the third group were computer navigated primary total knees. Patients in all three groups were age and sex matched. The senior author advocating use of the five degree block aimed to obtain a five degree posterior slope. The senior author who advocated the use of computer navigation, or the traditional zero degree cutting block, aimed to obtain a three degree posterior slope. All operations were performed by residents or clinical fellows, under the supervision of the senior authors. Patient radiographs were assessed to obtain the optimal direct lateral view obtained and they were saved on a database. Two independent blinded researchers assessed the posterior slope using Siemens Magicweb Software Version VA42C_0206. Two methods were used and the results averaged. The average posterior slope for the navigated total knee replacements was 0.1 degrees (−2 to 4). The average posterior slope for the five degree cutting block was 5.2 degrees (−2 to 16). The average posterior slope for the zero degree block was 3.79 degrees (−2 to 13). Computer navigated knee arthroplasty patients had significantly less variation in outlier measurements compared to the traditionally jigged arthroplasty patients. They were however, less accurate. The five degree cutting block tended to provide a more consistent posterior slope angle, but both the five degree and zero degree cutting blocks had variability in outliers. Computer Navigated Total Knee replacement provides a more consistent and reproducible tibial cut with less variability in alignment than extra-medullary jigs. The traditional five degree cutting block tended to provide a more reliable five degree posterior slope than the zero degree block, but was still subject to outliers.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 68 - 68
1 Mar 2012
Higgins G Kuzyk P Olsen M Waddell J Schemitsch E
Full Access

The aim of this study was to determine the mid-term survival and functional outcomes of the Scorpio Total Stabilised Revision Knee prosthesis.

Sixty seven prostheses were implanted between November 2001 and April 2008. 42 females and 23 males. Average patient age was 67.9 (37-89). Outcomes were assessed with WOMAC (Western Ontario and McMaster Universities Osteoarthritis index), Knee Society Scores, Short Form-8 scores, patient satisfaction and radiological review. Average follow-up was over 3 years (8-93mths) with 95% follow-up.

One patient died post operatively and 4 patients from 18 months to 5 years post-operatively. Average body mass index was 32.9 (21.5- 55.1). 65% (42 patients) of patients operated on had a Body Mass Index of greater than 30. 48 patients were ASA 3 or greater.

Thirteen second stage revision arthroplasties were performed after treatment for infected arthroplasty surgery. Twenty six prostheses were revised for aseptic loosening. Eight prostheses were revised for stiffness and 9 for worn polyethylene inserts. Five prostheses were revised for symptomatic tibio-femoral instability/ dislocation and one for patello-femoral instability. Two revisions were performed for peri-prosthetic fractures and 2 for previously operated tibial plateau fractures.

Seven patients required tibial tubercle osteotomy and seven a rectus snip. Thirty one patients had greater than a 15mm polyethylene insert. The average KSS increased from 49 pre-operatively to 64 at 7.5 years. The average KS function score increased from 21 to 45. 68% (44) of patients had other significant joint involvement which affected daily function. 24% of patients were unsatisfied with the outcome. 89.5% of patients radiographs were assessed for loosening or subsidence. 51% of femoral components and 36% of tibial components had radiosclerotic lines. The surface area of each implant including the stem was measured on antero-posterior and lateral images. The degree of lucency was calculated as a percentage and in mm from the component.

Two prostheses (3%) were revised for deep infection, one (1.5%) for stiffness and one for aseptic loosening (1.5%). Complications included a popliteal artery injury, two superficial wound infections, and one patella tendon avulsion.

Survival rate for revision of prosthesis was 87% at 7.5 years and 90% excluding infection. Success of second stage revision arthroplasty after treatment of infection was 92%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 4 - 4
1 Mar 2012
Higgins G Kuzyk P Tunggal J Waddell J Schemitsch E
Full Access

The purpose of this study was to evaluate 3 methods used to produce posterior tibial slope.

Methods

110 total knee arthroplasties performed during a 4 year period were included(2005 to 2009). All operations were performed by 2 surgeons. Group 1 used an extramedullary guide with a 0 degree cutting block tilted by placing 2 fingers between the tibia and the extramedullary guide proximally and three fingers distally to produce a 3 degree posterior slope (N=40). Group 2 used computer navigation to produce a 3 degree posterior slope (N=30). Group 3 used an extramedullary guide placed parallel to the anatomic axis of the tibia with a 5 degree cutting block to produce a 5 degree slope (N=40).

Posterior tibial slope was measured by 2 independent blinded reviewers. The reported slope for each sample was the average of these measurements. All statistical calculations were performed using SPSS Windows Version 16.0 (SPSS Inc., IL, USA).

Results

There was excellent agreement for the mean posterior slopes measured by the 2 independent reviewers. The linear correlation constant was 0.87 (p<0.01). The paired t test showed no significant difference (p=0.82).

The measurements for Group 1 (4.15±3.24 degrees) and Group 2 (1.60±1.62 degrees) were both significantly different to the ideal slope of 3 degrees (p=0.03 for Group 1 and p<0.01 for Group 2). The mean posterior tibial slope of Group 3 (5.00±2.87 degrees) was not significantly different to the ideal posterior tibial slope of 5 degrees (p=1.00). Group 2 exhibited the lowest standard deviation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 18 - 18
1 Feb 2012
Aslam N Pan J Schemitsch E Waddell J
Full Access

The purpose of this study was to evaluate total hip arthroplasty (THA) in the treatment of post-traumatic arthritis following acetabular fracture and to compare the long-term outcome of THA after previous open reduction and internal fixation (ORIF) or conservative treatment of the acetabular fracture.

Thirty-four patients (thirty-six hips) underwent total hip arthroplasty for arthritis resulting from acetabular fractures. There were twenty-six males (27 hips) and eight females (9 hips). The mean age at the time of hip arthroplasty was 49 years (range, 25-78 years). The mean follow-up was eight years and nine months (range, 4-17 years). The mean interval from fracture to arthroplasty was 7.5 years (range, 5 months-29 years). Two patients died of unrelated causes and two patients were lost to follow-up. Thirty patients (32 hips) were available for latest follow-up. Twenty-one hips had been previously treated by open reduction internal fixation and 11 hips had conservative treatment.

Sixteen patients achieved and maintained a good to excellent result over the course of the follow-up. There was no difference in improvement of mean Harris Hip Score between both groups (p>0.05). Ten out of 32 hips required revision; 9 acetabular components were revised because of aseptic loosening (3), osteolysis/excessive wear (4), instability (1) and infection (1) with a total revision rate of 28%. Eight patients needed acetabular revision alone, one femoral revision alone and one revision of both components. There was no significant difference in bone grafting, heterotopic bone formation, revision rate, operative time and blood loss between the two groups (p> 0.05).

Those patients initially treated conservatively had similar long term results compared to those treated primarily by open reduction internal fixation. At long term follow-up the main problem identified was osteolysis and acetabular wear.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 5 - 5
1 Feb 2012
Davis E Lingard E Schemitsch E Waddell J
Full Access

We aimed to identify whether patients in lower socioeconomic groups had worse function prior to total knee arthroplasty and to establish whether these patients had worse post-operative outcome following total knee arthroplasty.

Data were obtained from the Kinemax outcome study, a prospective observational study of 974 patients undergoing primary total knee arthroplasty for osteoarthritis. The study was undertaken in thirteen centres, four in the United States, six in the United Kingdom, two in Australia and one in Canada. Pre-operative data were collected within six weeks of surgery and patients were followed for two years post-operatively. Pre-operative details of the patient's demographics, socioeconomic status (education and income), height, weight and co-morbid conditions were obtained. The WOMAC and SF-36 scores were also obtained. Multivariate regression was utilised to analyse the association between socioeconomic status and the patient's pre-operative scores and post-operative outcome. During the analysis, we were able to control for variables that have previously been shown to effect pre-operative scores and post-operative outcome.

Patients with a lower income had a significantly worse pre-operative WOMAC pain (p=0.021) and function score (p=0.039) than those with higher incomes. However, income did not have a significant impact on outcome except for WOMAC Pain at 12-months (p=0.014). At all the other post-operative assessment times, there was no correlation between income and WOMAC Pain and WOMAC Function. Level of education did not correlate with pre-operative scores or with outcome at any time during follow-up. This study demonstrates that across all four countries, patients with lower incomes appear to have a greater need for total knee arthroplasty. However, level of income and educational status did not appear to affect the final outcome following total knee arthroplasty. Patients with lower incomes appear able to compensate for their worse pre-operative score and obtain similar outcomes post-operatively.