header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Knee

MID-TERM RESULTS OF REVISION ARTHROPLASTY USING THE SCORPIO TOTAL STABILISED REVISION KNEE SYSTEM

British Association for Surgery of the Knee (BASK)



Abstract

The aim of this study was to determine the mid-term survival and functional outcomes of the Scorpio Total Stabilised Revision Knee prosthesis.

Sixty seven prostheses were implanted between November 2001 and April 2008. 42 females and 23 males. Average patient age was 67.9 (37-89). Outcomes were assessed with WOMAC (Western Ontario and McMaster Universities Osteoarthritis index), Knee Society Scores, Short Form-8 scores, patient satisfaction and radiological review. Average follow-up was over 3 years (8-93mths) with 95% follow-up.

One patient died post operatively and 4 patients from 18 months to 5 years post-operatively. Average body mass index was 32.9 (21.5- 55.1). 65% (42 patients) of patients operated on had a Body Mass Index of greater than 30. 48 patients were ASA 3 or greater.

Thirteen second stage revision arthroplasties were performed after treatment for infected arthroplasty surgery. Twenty six prostheses were revised for aseptic loosening. Eight prostheses were revised for stiffness and 9 for worn polyethylene inserts. Five prostheses were revised for symptomatic tibio-femoral instability/ dislocation and one for patello-femoral instability. Two revisions were performed for peri-prosthetic fractures and 2 for previously operated tibial plateau fractures.

Seven patients required tibial tubercle osteotomy and seven a rectus snip. Thirty one patients had greater than a 15mm polyethylene insert. The average KSS increased from 49 pre-operatively to 64 at 7.5 years. The average KS function score increased from 21 to 45. 68% (44) of patients had other significant joint involvement which affected daily function. 24% of patients were unsatisfied with the outcome. 89.5% of patients radiographs were assessed for loosening or subsidence. 51% of femoral components and 36% of tibial components had radiosclerotic lines. The surface area of each implant including the stem was measured on antero-posterior and lateral images. The degree of lucency was calculated as a percentage and in mm from the component.

Two prostheses (3%) were revised for deep infection, one (1.5%) for stiffness and one for aseptic loosening (1.5%). Complications included a popliteal artery injury, two superficial wound infections, and one patella tendon avulsion.

Survival rate for revision of prosthesis was 87% at 7.5 years and 90% excluding infection. Success of second stage revision arthroplasty after treatment of infection was 92%.