header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

Total Hip Arthroplasty Following Failure of Core Decompression and Tantalum Rod Insertion for Femoral Head Avascular Necrosis

International Society for Technology in Arthroplasty (ISTA)



Abstract

Introduction:

One method of femoral head preservation following avascular necrosis (AVN) is core decompression and Tantalum Rod insertion. There is, however, a published failure rate of up to 32% at 4 years. The purpose of the present study was to document the clinical and radiological outcome following Total Hip Arthroplasty (THA) subsequent to failed Tantalum Rod insertion.

Methods:

Twenty-five failed Tantalum Rod insertions subsequently requiring THA were identified from a prospectively updated database. Seventeen patients met minimum 2 year clinical and radiographic follow-up criteria. St. Michael's Hip (SMH) scores were compared to a matched cohort of patients with THA for AVN without prior Tantalum Rod insertion. Postoperative radiographs were reviewed assessing component alignment, linear wear (Dorr & Wan) and presence of tantalum residue within the joint space.

Results:

Nine females and eight males underwent removal of a Tantalum Rod with subsequent THA between May 2005 and March 2010. The mean time between Tantalum Rod insertion and conversion to THA was 23 months (range 6–48) with a mean follow-up of 3.5 years (range 2–5). At each follow-up interval the mean SMH scores were comparable between the two groups (p = 0.445). Femoral stem alignment (p = 0.428) and acetabular cup inclination (p = 0.723) were comparable between groups. Articular tantalum residue was identified in 12 of 17 articulations (7 mild, 3 moderate, 2 severe). Linear wear rates were comparable between the tantalum group (0.07 mm/yr, range 0.01–0.40) and controls (0.07 mm/yr, range 0.02–0.21, p = 0.951). There was no evidence of catastrophic wear.

Conclusion:

Tantalum rod conversion to THA in the young adult patient with AVN reveals no early catastrophic sequelae. In the short term, Tantalum Rod insertion does not demonstrate a deleterious effect on subsequent total joint replacement surgery. There is, however, a high rate of retained tantalum debris within the effective joint space with the procedure and thus there is an unknown risk of accelerated articular wear necessitating longer term study.


*Email: