header advert
Results 1 - 50 of 77
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 22 - 22
2 May 2024
Logishetty K Whitwell D Palmer A Gundle R Gibbons M Taylor A Kendrick B
Full Access

There is a paucity of data available for the use of Total Femoral Arthroplasty (TFA) for joint reconstruction in the non-oncological setting. The aim of this study was to evaluate TFA outcomes with minimum 5-year follow-up.

This was a retrospective database study of TFAs performed at a UK tertiary referral revision arthroplasty unit. Inclusion criteria were patients undergoing TFA for non-oncological indications. We report demographics, indications for TFA, implant survivorship, clinical outcomes, and indications for re-operation.

A total of 39 TFAs were performed in 38 patients between 2015–2018 (median age 68 years, IQR 17, range 46–86), with 5.3 years’ (IQR 1.2, 4.1–18.8) follow-up; 3 patients had died. The most common indication (30/39, 77%) for TFA was periprosthetic joint infection (PJI) or fracture-related infection (FRI); and 23/39 (59%) had a prior periprosthetic fracture (PPF). TFA was performed with dual-mobility or constrained cups in 31/39 (79%) patients. Within the cohort, 12 TFAs (31%) required subsequent revision surgery: infection (7 TFAs, 18%) and instability (5 TFAs, 13%) were the most common indications. 90% of patients were ambulatory post-TFA; 2 patients required disarticulation due to recurrent PJI. While 31/39 (79%) were infection free at last follow-up, the remainder required long-term suppressive antibiotics.

This is the largest series of TFA for non-oncological indications. Though TFA has inherent risks of instability and infection, most patients are ambulant after surgery. Patients should be counselled on the risk of life-long antibiotics, or disarticulation when TFA fails.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 59 - 59
24 Nov 2023
McCulloch R Martin A Kendrick B Jeys L Alvand A Young B Taylor A Stevenson J Palmer A
Full Access

Introduction

A proportion of patients with hip and knee prosthetic joint infection (PJI) undergo multiple revisions with the aim of eradicating infection and improving quality of life. The aim of this study was to describe the microbiology cultured from multiply revised hip and knee replacement procedures to guide antimicrobial therapy at the time of surgery.

Patients and Methods

Consecutive patients were retrospectively identified from databases at two specialist orthopaedic centres in the United Kingdom between 2011 and 2019. Patient were included who had undergone repeat revision total knee replacement (TKR) or total hip replacement (THR) for infection, following an initial failed revision for infection.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 32 - 32
7 Jun 2023
Howgate D Roberts PG Palmer A Price A Taylor A Rees J Kendrick B
Full Access

Primary total hip replacement (THR) is a successful and common operation which orthopaedic trainees must demonstrate competence in prior to completion of training. This study aimed to determine the impact of operating surgeon grade and level of supervision on the incidence of 1-year patient mortality and all-cause revision following elective primary THR in a large UK training centre.

National Joint Registry (NJR) data for all elective primary THR performed in a single University Teaching Hospital from 2005–2020 were used, with analysis performed on the 15-year dataset divided into 5-year temporal periods (B1 2005–2010, B2 2010–2015, B3 2015–2020). Outcome measures were mortality and revision surgery at one year, in relation to lead surgeon grade, and level of supervision for trainee-led operations.

9999 eligible primary THR were undertaken, of which 5526 (55.3%) were consultant led (CL), and 4473 (44.7%) trainees led (TL). Of TL, 2404 (53.7%) were non-consultant supervised (TU), and 2069 (46.3%) consultant supervised (TS). The incidence of 1-year patient mortality was 2.05% (n=205), and all-cause revision was 1.11% (n=111). There was no difference in 1-year mortality between TL (n=82, 1.8%) and CL (n=123, 2.2%) operations (p=0.20, OR 0.78, CI 0.55–1.10). The incidence of 1-year revision was not different for TL (n=56, 1.3%) and CL (n=55, 1.0%) operations (p=0.15, OR 1.37, CI 0.89–2.09). Overall, there was no temporal change for either outcome measure between TL or CL operations. A significant increase in revision within 1-year was observed in B3 between TU (n=17, 2.7%) compared to CL (n=17, 1.0%) operations (p=0.005, OR 2.81, CI 1.35–5.87).

We found no difference in 1-year mortality or 1-year all-cause revision rate between trainee-led primary THR and consultant-led operations over the entire fifteen-year period. However, unsupervised trainee led THR in the most recent 5-year block (2015–2020) has a significantly increased risk of early revision, mainly due to instability and prosthetic joint infection. This suggests that modern surgical training is having a detrimental effect on THR patient outcomes. More research is needed to understand the reasons if this trend is to be reversed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 19 - 19
1 Oct 2022
Schenk HM Sebillotte M Lomas J Taylor A Benavent E Murillo O Fernandez-Sampedro M Huotari K Aboltins C Trebse R Soriano A Wouthuyzen-Bakker M
Full Access

Aim

Patients with late acute periprosthetic joint infections (PJI) and treated with surgical debridement have a high failure rate. Previous studies have shown that rheumatoid arthritis (RA) is an independent risk factor for treatment failure. We conducted a case-control study to identify predictors for failure in late acute PJI treatment in RA patients. We hypothesize that patients with RA have a higher failure rate compared to controls due to the use of immunosuppressive drugs.

Method

Data of an international multicenter retrospective observational study was used. Late acute PJI was defined as a sudden onset of symptoms and signs of a PJI, more than 3 months after implantation. Failure of treatment was defined as persistent signs of infection, relapse with the same or reinfection with a different micro-organism, need for prosthesis removal or death. Cases with RA were matched with cases without RA based on the affected joint. A Cox survival analyses, stratified for RA, was used to calculate hazard ratio's (HR) for failure. Subgroup analyses were used to explore other predictors for treatment failure in RA patients.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 37 - 37
1 Jul 2022
McCulloch R Palmer A Donaldson J Kendrick B Warren S Atkins B Alvand A Carrington R Taylor A Miles J
Full Access

Abstract

Aims

The primary aim of this study was to evaluate the outcomes of fungal knee periprosthetic joint infection following knee arthroplasty. The secondary aim was to evaluate risk factors for acquiring a fungal PJI.

Patients and Methods

This was a retrospective analysis of patients presenting with a confirmed fungal PJI of the knee in two tertiary centres. There were a total of 45 cases. Isolated fungal infections along with mixed bacterial and fungal infections were included. Mean follow up was 40 months (range 3–118).


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 729 - 735
1 Jun 2022
Craxford S Marson BA Nightingale J Forward DP Taylor A Ollivere B

Aims

The last decade has seen a marked increase in surgical rib fracture fixation (SRF). The evidence to support this comes largely from retrospective cohorts, and adjusting for the effect of other injuries sustained at the same time is challenging. This study aims to assess the impact of SRF after blunt chest trauma using national prospective registry data, while controlling for other comorbidities and injuries.

Methods

A ten-year extract from the Trauma Audit and Research Network formed the study sample. Patients who underwent SRF were compared with those who received supportive care alone. The analysis was performed first for the entire eligible cohort, and then for patients with a serious (thoracic Abbreviated Injury Scale (AIS) ≥ 3) or minor (thoracic AIS < 3) chest injury without significant polytrauma. Multivariable logistic regression was performed to identify predictors of mortality. Kaplan-Meier estimators and multivariable Cox regression were performed to adjust for the effects of concomitant injuries and other comorbidities. Outcomes assessed were 30-day mortality, length of stay (LoS), and need for tracheostomy.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 22 - 22
1 Apr 2022
France J Tucker A Norrish A Taylor A Ollivere B
Full Access

Introduction

The use of the Taylor Spatial Frame (TSF) in the management of tibial fractures and deformity correction is well established in the literature, however the majority of published papers are small in patient number. The aim of the project was to evaluate clinical and radiographic outcomes of patients with tibial fractures treated with a TSF.

Materials and Methods

A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, frame construct, time duration in frame, union rates and complications of treatment.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 84 - 84
1 Dec 2021
Hotchen A Wismayer M Robertson-Waters E McDonnell S Kendrick B Taylor A Alvand A McNally M
Full Access

Aim

This study assesses the ability of the JS-BACH classification of bone infection to predict clinical and patient-reported outcomes in prosthetic joint infection (PJI).

Method

Patients who received surgery for suspected PJI at two specialist bone infection centres within the UK between 2010 and 2015 were classified using the JS-BACH classification into either ‘uncomplicated’, ‘complex’ or ‘limited options’. All patients were classified by two clinicians blinded to outcome, with any discrepancies adjudicated by a third reviewer. At the most recent follow-up, patients were assessed for (i) any episode of recurrence since the index operation and (ii) the status of the joint. A Cox proportional-hazard model assessed significant predictors of recurrence following the index procedure. Patient-reported outcomes included the EuroQol EQ-5D-3L index score and the EQ-visual analogue score (VAS) at 0, 14, 42, 120 and 365 days following the index operation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 31 - 31
1 Aug 2021
Ahmed B George D El Ashmawy A Minhas Z Palmer A Taylor A Kendrick B
Full Access

Treatment of periprosthetic joint infection (PJI) can include local delivery of antibiotics. A frequently used medium is absorbable calcium sulphate beads. The aims of this study were to:

identify how often organisms in infected THRs are sensitive to the added antibiotics

establish the incidence of persistent wound discharge and hypercalcaemia

All patients who received an antibiotic loaded calcium sulphate carrier (Stimulan, Biocomposites, Keele, UK) for either confirmed infection, presumed infection or for prophylaxis between July 2015 and July 2020 were included. Stimulan use was at the discretion of the surgeon, and between 10 and 40cc was used. In the absence of a known organism we routinely used 1g vancomycin and 240mg gentamicin per 10 cc of calcium sulphate. Post-operative sensitivities for all organisms cultured were compared to the antibiotics delivered locally. Persistent wound drainage was defined as discharge beyond the third postoperative day. Patients had serum calcium measured if they developed symptoms consistent with hypercalcaemia (Ca >2.6 mmol/L) or the clinical team felt they were at high risk.

189 patients (mean age 66.9 years, mean BMI 28.9, 85 male, 104 female) were included. 11 patients had a native joint septic arthritis, 42 presented with acute PJI and 136 presented with chronic PJI. 133 patients grew an organism, of which 126 were sensitive to the added antibiotics. Of the seven patients with resistant growth five had vancomycin-resistent Enterococcus, one Pseudomonas and one multi-organism growth including coagulase negative Staphylococcus. 40 patients experienced persistent wound discharge, with eight requiring re-operation. All other cases settled with dressing management. 12 patients developed hypercalcaemia (3/64 10cc, 7/117 20cc, 0/2 30cc and 2/6 40cc). The peak calcium reading ranged between the second and twelfth post-operative day.

The addition of vancomycin and gentamicin to absorbable calcium sulphate covers the majority of organisms found in culture positive infection in our cohort. It also appears safe, with an acceptable incidence of hypercalcaemia or wound discharge. Further work is required to identify patients at greatest risk of culturing resistant organisms or delayed wound healing.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1173 - 1173
1 Jun 2021
Alsousou J Oragui E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 644 - 649
1 Apr 2021
Alsousou J Oragu E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S

Aims

The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA).

Methods

A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 25 - 25
1 Feb 2020
De Villiers D Collins S Taylor A Dickinson A
Full Access

INTRODUCTION

Hip resurfacing offers a more bone conserving solution than total hip replacement (THR) but currently has limited clinical indications related to some poor design concepts and metal ion related issues. Other materials are currently being investigated based on their successful clinical history in THR such as Zirconia Toughened Alumina (ZTA, Biolox Delta, CeramTec, Germany) which has shown low wear rates and good biocompatibility but has previously only been used as a bearing surface in THR. A newly developed direct cementless fixation all-ceramic (ZTA) resurfacing cup offers a new solution for resurfacing however ZTA has a Young's modulus approximately 1.6 times greater than CoCr - such may affect the acetabular bone remodelling. This modelling study investigates whether increased stress shielding may occur when compared to a CoCr resurfacing implant with successful known clinical survivorship.

METHODS

A finite element model of a hemipelvis constructed from CT scans was used and virtually reamed to a diameter of 58mm. Simulations were conducted and comparisons made of the ‘intact’ acetabulum and ‘as implanted’ with monobloc cups made from CoCr (Adept®, MatOrtho Ltd, UK) and ZTA (ReCerf ™, MatOrtho Ltd. UK) orientated at 35° inclination and 20° anteversion. The cups were loaded with 3.97kN representing a walking load of 280% for an upper bound height patient with a BMI of 35. The cup-bone interface was assigned a coulomb slip-stick function with a coefficient of friction of 0.5. The percentage change in strain energy density between the intact and implanted states was used to indicate hypertrophy (increase in density) or stress shielding (decrease in density).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 15 - 15
1 Dec 2019
Minhas Z Palmer A Alvand A Taylor A Kendrick B
Full Access

Introduction

Antibiotic loaded absorbable calcium sulphate beads (ALCSB) are an increasingly popular adjunct in the treatment of musculoskeletal infections including osteomyelitis and peri-prosthetic joint infections (PJI). Limited data exist regarding the clinical indications and biochemical outcomes of ALCSB in PJI cases.

Aims

To determine the proportion of organisms that were sensitive to the gentamicin and vancomycin that we add to the ALCSB as a part of our treatment protocol and to determine the prevalence of postoperative hypercalcaemia when used for treatment of hip and knee DAIR (debridement and implant retention) and revision arthroplasty for PJI.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 40 - 40
1 May 2019
Vanhegan I Martin A Gundle R Taylor A Kendrick B
Full Access

Introduction

We are a high-volume arthroplasty unit performing over 800 primary THRs annually at an approximate reimbursement of £6.5 million to the Trust. 70% are hybrid and we have been using the Taperfit - Trinity combination (Corin, Cirencester) since March 2016. We aimed to investigate the potential cost-savings and clinical benefits of instrument rationalisation using this system following GIRFT principles.

Methods

Taperfit (ODEP 10A) is a polished, collarless, double tapered stem available in multiple sizes/offsets. Trinity is a hemispherical porous titanium cementless shell. A prospective audit of implant size was performed for the first 50 cases. Based on these findings, instruments were reduced to a single tray per component based on predicted size, named ‘Corin Hip for the Osteoarthritic Patient’ (CHOP). A further re-audit was performed to confirm correct tray constituent sizes. Financial data were calculated using known TSSU costs of approximately £50 per tray.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 11 - 11
1 May 2019
Jordan S Taylor A Jhaj J Akehurst H Ivory J Ashmore A Rigby M Brooks R
Full Access

Background

Total hip arthroplasty (THA) is increasingly used for active patients with displaced intracapsular hip fractures. Dislocation rates in this cohort remain high postoperatively compared to elective practice, yet it remains unclear which patients are most at risk. The aim of this study was to determine the dislocation rate for these patients and to evaluate the contributing patient and surgeon factors.

Methods

A five-year retrospective analysis of all patients receiving THA for displaced intracapsular hip fractures from 2013–18 was performed. Data was collected from the institutions' hip fracture database, including data submitted to the National Hip Fracture Database (NHFD). Cox regression analysis and log-rank tests were implemented to evaluate factors associated with THA dislocation. Patient age, sex, ASA grade, surgeon seniority, surgical approach, femoral head diameter and acetabular cup type were all investigated as independent factors.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 93 - 93
1 Apr 2019
Avila C Taylor A Collins S
Full Access

INTRODUCTION

Unlike current acetabular cups, this novel ceramic cup has a Ti/HA coating which removes the requirement for assembly into a metal shell which avoiding potential chipping/misalignment and reducing wall thickness [Figure 1]. This study examines the resistance of novel thin-walled, direct to bone fixation ceramic cups to critical impact loads.

METHODS

Samples of the smallest (Ø46mm) and largest (Ø70mm) diameter ReCerfTM acetabular cups and corresponding femoral head implants were implanted into Sawbones foam blocks considered representative of pelvic cancellous bone. Two different positional configurations were tested and were considered worst case and the extremes of surgical compromise; P1 simulates the cup fully supported by the acetabulum with a high inclination angle (70°) and a vertical impaction axis (worst case loading near the cup rim) and. P2 simulates the cup implanted with a lower inclination (55°) but with the superior section unsupported by acetabulum bone [Figure 2]. For each size, three acetabular cups were tested in each position. The impact fixture was positioned within a drop weight rig above a bed of sand and ≈22mm of pork belly representative of soft tissues damping effect and the implant components aligned to achieve the defined impact point on the cup [Figure 2]. Lateral falls were tested on all available samples applying impact energy of 140J [1] and 3m/s impact velocity [2]. After the lateral fall test, each sample was tested under impact conditions equivalent to a frontal car crash considering a peak impact force of 5.7kN occurring 40ms from initial contact (able to produce acetabular fracture)[3].


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 21 - 21
1 Dec 2018
Harrison C Alvand A Chan J West E Matthews P Taylor A Giele H McNally M Ramsden A
Full Access

Aim

A number of orthopaedic strategies have been described for limb salvage following periprosethic joint infection (PJI). However, this is often only possible with concomitant soft tissue reconstruction in the form of flap coverage. The purpose of this study was to determine the long-term clinical outcome of patients who underwent pedicled gastrocnemius flap coverage as part of their treatment for knee PJI.

Method

We performed a retrospective review of all patients undergoing gastrocnemius muscle transfer with split thickness skin grafting as part of their treatment for knee PJI at a tertiary referral centre between 1994 and 2015. Data recorded included patient characteristics, orthopaedic procedure, microbiology result and antimicrobial management. Outcome measures included flap failure, infection recurrence, amputation, functional outcome (Oxford knee score; OKS) and mortality.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 92 - 92
1 Dec 2018
Wouthuyzen-Bakker M Sebillotte M Lomas J Taylor A Palomares EB Murillo O Parvizi J Shohat N Reinoso JC Sánchez RE Fernandez-Sampedro M Senneville E Huotari K Allende JB Garcia-Cañete J Lora-Tamayo J Ferrari MC Vaznaisiene D Yusuf E Aboltins C Trebse R Salles M Benito N Vila A Del Toro MD Kramer T Petershof S Diaz-Brito V Tufan ZK Sanchez M Arvieux C Soriano A
Full Access

Aim

Debridement, antibiotics and implant retention (DAIR) is the recommended treatment for all acute prosthetic joint infections (PJI). However, the efficacy of DAIR and identification of risk factors for failure in patients with late acute PJI, is not well described.

Method

Patients diagnosed with late acute PJI between 2005 and 2015 were retrospectively evaluated. Late acute PJI was defined as the development of acute symptoms (≤ 3 weeks) occurring ≥ 3 months after arthroplasty. Failure was defined as: i) the need for implant removal, ii) infection related death, iii) the need for suppressive antibiotic therapy due to persistent signs of infection and/or iv) relapse or reinfection during follow-up.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1148 - 1156
1 Sep 2018
Ferguson RJ Broomfield JA Malak TT Palmer AJR Whitwell D Kendrick B Taylor A Glyn-Jones S

Aims

The aim of this study was to determine the stability of a new short femoral stem compared with a conventional femoral stem in patients undergoing cementless total hip arthroplasty (THA), in a prospective randomized controlled trial using radiostereometric analysis (RSA).

Patients and Methods

A total of 53 patients were randomized to receive cementless THA with either a short femoral stem (MiniHip, 26 patients, mean age: 52 years, nine male) or a conventional length femoral stem (MetaFix, 23 patients, mean age: 53 years, 11 male). All patients received the same cementless acetabular component. Two-year follow-up was available on 38 patients. Stability was assessed through migration and dynamically inducible micromotion. Radiographs for RSA were taken postoperatively and at three, six, 12, 18, and 24 months.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1146 - 1147
1 Sep 2018
Ferguson RJ Broomfield JA Malak TT Palmer AJR Whitwell D Kendrick B Taylor A Glyn-Jones S


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 37 - 37
1 May 2018
Ferguson R Broomfield J Malak T Palmer A Whitwell D Taylor A Glyn-Jones S
Full Access

Background

Short bone-conserving femoral stem implants were developed to achieve more physiological, proximal bone loading than conventional femoral stems. Concerns have arisen, however, that improved loading may be offset by lower primary stability because of the reduced potential area for bony contact.

Aims

The aim of this study was to determine the primary stability of a novel short femoral stem compared with a conventional femoral stem following cementless total hip arthroplasty (THA), in a prospective, blinded, randomised, controlled trial using radiostereometric analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 11 - 11
1 May 2018
Alvand A Grammatopoulos G Quiney F Taylor A Whitwell D Price A Dodd C Jackson W Gibbons M
Full Access

Endoprosthetic replacement (EPR) is an available option for the management of massive bone loss around failed knee implants. The aim of this study was to determine the results of knee EPRs performed for non-tumour indications. Since 2007, 85 EPRs were performed for in a single tertiary centre by seven surgeons. Mean age at surgery was 73.5 years (range:35–95) with infection as the most common indication (49%), followed by aseptic loosening (18%), complex primary replacement (16%), fracture (15%) and mechanical failure (2%). Mean follow up was 4 years (range:1–9). Functional outcome was determined using the Oxford Knee Score (OKS). At follow-up, 21 patients were deceased and 2 lost to follow-up. Complication rate was 19%. Of the 7 infected cases, 6 were treated with DAIR (debridement, antibiotics, and implant retention) and one underwent above knee amputation. Four of the patients undergoing DAIR were cleared of infection and 2 are on long-term antibiotics. Accounting for implant revision, loss to follow-up and those on long-term antibiotics as failures, 5-year survival was 89% with an average OKS of 25 (SD=10). This mid-term study shows that distal femur EPR is a valuable option for the increasing burden of complex revision knee surgery


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 43 - 43
1 Dec 2017
Alvand A Li HK Rombach I Zambellas R Kendrick B Taylor A Atkins B Bejon P McNally M Scarborough M
Full Access

Aim

To assess the influence of route of antibiotic administration on patient-reported outcome measures (PROMS) of individuals treated for hip and knee infections in the OVIVA multi-centre randomised controlled trial.

Method

This study was designed to determine whether oral antibiotic therapy is non-inferior to intravenous (IV) therapy when given for the first six weeks of treatment for bone and joint infections. Of the 1054 participants recruited from 26 centres, 462 were treated for periprosthetic or native joint infections of the hip or knee. There were 243 participants in the IV antibiotic cohort and 219 in the oral cohort. Functional outcome was determined at baseline through to one year using the Oxford Hip/Knee Score (OHS/OKS) as joint-specific measures (0 the worse and 48 the best). An adjusted quantile regression model was used to compare functional outcome scores.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 101 - 101
1 Dec 2017
Street T Sanderson N Atkins B Brent A Cole K Foster D McNally M Oakley S Peto L Taylor A Peto T Crook D Eyre D
Full Access

Aim

Culture of multiple periprosthetic tissue samples is the current gold-standard for microbiological diagnosis of prosthetic joint infections (PJI). Additional diagnostic information may be obtained through sonication fluid culture of explants. These current techniques can have relatively low sensitivity, with prior antimicrobial therapy or infection by fastidious organisms particularly influencing culture results. Metagenomic sequencing has demonstrated potential as a tool for diagnosis of bacterial, viral and parasitic infections directly from clinical samples, without the need for an initial culture step. We assessed whether metagenomic sequencing of DNA extracts from sonication fluid can provide a sensitive tool for diagnosis of PJI compared to sonication fluid culture.

Method

We compared metagenomic sequencing with standard aerobic and anaerobic culture in 97 sonication fluid samples from prosthetic joint and other orthopaedic device-related infections. Sonication fluids were filtered to remove whole human cells and tissue debris, then bacterial cells were mechanically lysed before DNA extraction. DNA was sequenced and sequencing reads were taxonomically classified using Kraken. Using 50 derivation samples, we determined optimal thresholds for the number and proportion of bacterial reads required to identify an infection and confirmed our findings in 47 independent validation samples.


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 41 - 48
1 Apr 2017
Fernquest S Arnold C Palmer A Broomfield J Denton J Taylor A Glyn-Jones S

Aims

The aim of this study was to examine the real time in vivo kinematics of the hip in patients with cam-type femoroacetabular impingement (FAI).

Patients and Methods

A total of 50 patients (83 hips) underwent 4D dynamic CT scanning of the hip, producing real time osseous models of the pelvis and femur being moved through flexion, adduction, and internal rotation. The location and size of the cam deformity and its relationship to the angle of flexion of the hip and pelvic tilt, and the position of impingement were recorded.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 53 - 53
1 Jan 2017
Devivier C Roques A Taylor A Heller M Browne M
Full Access

There is a critical need for safe innovation in total joint replacements to address the demands of an ageing yet increasingly active population. The development of robust implant designs requires consideration of uncertainties including patient related factors such as bone morphology but also activity related loads and the variability in the surgical procedure itself. Here we present an integrated framework considering these sources of variability and its application to assess the performance of the femoral component of a total hip replacement (THR).

The framework offers four key features. To consider variability in bone properties, an automated workflow for establishing statistical shape and intensity models (SSIM) was developed. Here, the inherent relationship between shape and bone density is captured and new meshes of the target bone structures are generated with specific morphology and density distributions. The second key feature is a virtual implantation capability including implant positioning, and bone resection. Implant positioning is performed using automatically identified bone features and flexibly defined rules reflecting surgical variability. Bone resection is performed according to manufacturer guidelines. Virtual implantation then occurs through Boolean operations to remove bone elements contained within the implant's volume. The third feature is the automatic application of loads at muscle attachment points or on the joint contact surfaces defined on the SSIM. The magnitude and orientation of the forces are derived from models of similar morphology for a range of activities from a database of musculoskeletal (MS) loads. The connection to this MS loading model allows the intricate link between morphology and muscle forces to be captured. Importantly, this model of the internal forces provides access to the spectrum of loading conditions across a patient population rather than just typical or average values. The final feature is an environment that allows finite element simulations to be run to assess the mechanics of the bone-implant construct and extract results for e.g. bone strains, interface mechanics and implant stresses. Results are automatically processed and mapped in an anatomically consistent manner and can be further exploited to establish surrogate models for efficient subsequent design optimization. To demonstrate the capability of the framework, it has been applied to the femoral component of a THR.

An SSIM was created from 102 segmented femurs capturing the heterogeneous bone density distributions. Cementless femoral stems were positioned such that for the optimal implantation the proximal shaft axis of the femurs coincided with the distal stem axis and the position of the native femoral head centre was restored. Here, the resection did not affect the greater trochanter and the implantations were clinically acceptable for 10000 virtual implantations performed to simulate variability in patient morphology and surgical variation. The MS database was established from musculoskeletal analyses run for a cohort of 17 THR subjects obtaining over 100,000 individual samples of 3D muscle and joint forces. An initial analysis of the mechanical performance in 7 bone-implant constructs showed levels of bone strains and implant stresses in general agreement with the literature.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 56 - 56
1 Dec 2016
Kendrick B Grammatopoulos G Philpott A Pandit H Atkins B Bolduc M Alvand A Athanasou N McNally M McLardy-Smith P Murray D Gundle R Taylor A
Full Access

Aim

Advocates of Debridement-Antibiotics-and-Implant-Retention (DAIR) in hip peri-prosthetic joint infection (PJI) argue that a procedure not disturbing a sound prosthesis-bone interface is likely to lead to better survival and functional outcome compared to revision. However, no evidence supports this. This case-control study's aims were to compare outcome of DAIRs for infected 1° total hip arthroplasty (THA) with outcomes following 1° THA and 2-stage revisions of infected 1° THAs.

Method

We retrospectively reviewed all DAIRs, performed for confirmed infected 1° THR (DAIR-Group, n=80), in our unit between 1997–2013. Data recorded included patient demographics, medical history, type of surgery and organism identified. Outcome measures included complications, mortality, implant survivorship and functional outcome using the Oxford Hip Score (OHS). Outcome was compared with 2 control groups matched for gender and age; a cohort of 1° THA (1°-THA-Group, n=120) and a cohort of 2-stage revisions for infection (2-Stage-Revision-Group, n=66).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 4 - 4
1 Dec 2016
Alvand A Grammatopoulos G de Vos F Scarborough M Athanasou N Kendrick B Price A Gundle R Whitwell D Jackson W Taylor A Gibbons M
Full Access

Introduction

The burden of peri-prosthetic joint infection (PJI) following hip and knee surgery is increasing. Endoprosthetic replacement (EPR) is an option for management of massive bone loss resulting from infection around failed lower limb implants.

Aims

To determine clinical outcome of EPRs for treatment of PJI around the hip and knee joint.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1463 - 1470
1 Nov 2016
Grammatopoulos G Alvand A Martin H Whitwell D Taylor A Gibbons CLMH

Objectives

A possible solution for the management of proximal femoral bone loss is a modular femoral endoprosthesis (EPR). Although the outcome of EPRs in tumour surgery has been well described, the outcome of their use in revision hip surgery has received less attention. The aim of this study was to describe the outcome of using EPR for non-neoplastic indications.

Methods

A retrospective review of 79 patients who underwent 80 EPRs for non-neoplastic indications was performed, including the rates of complication and survival and the mean Oxford Hip Scores (OHS), at a mean of five years post-operatively. The mean age at the time of surgery was 69 years (28 to 93) and the mean number of previous operations on the hip was 2.4 (0 to 17). The most common indications for EPR implantation were periprosthetic joint infection (PJI) (n = 40), periprosthetic fracture (n = 12) and failed osteosynthesis of a proximal femoral fracture or complex trauma (n = 11).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 18 - 18
1 Jun 2016
Grammatopoulos G Hodhody G Lane J Taylor A Kendrick B Glyn-Jones S
Full Access

Image-guided intra-articular hip injection of local-anaesthetic and steroid is commonly used in the management of hip pain. It can be used as a diagnostic and/or therapeutic tool and is of low cost (£75). The aim of this study was to assess how often a hip injection has a therapeutic effect.

This is a retrospective, consecutive, case series of intra-articular hip injections performed in a tertiary referral hospital over a 2-year period (2013–4). Patients were identified from the radiology department's prospectively entered database. Clinical information, reason for injection and subsequent management was obtained from hospital records. All patients prospectively reported their pain levels in a numeric pain scale diary (out of 10) at various time points; pre-, immediately post-, 1st day-, 2nd day- and 2 weeks- post-injection. Only patients with complete pain scores at all time points were included (n=200, of the 250 injections performed over study period, 80%).

The majority of injections were performed for osteoarthritis (OA) treatment (82%). The pain was significantly reduced from a pre-injection score of 7.5 (SD:2) to 5.0 (SD:3) immediately post-injection(p<0.001); only 24 (11%) reported any worsening of pain immediately post-injection. Pain significantly reduced further to 3.8(SD:3) at 2-weeks post-injection (p<0.001). 50% of patients had at least a 3 point drop in reported pain. No improvement was seen in 18 patients and 10 (5%) reported worse pain at 2-weeks compared to pre-injection. Of the OA cohort, 10% have required repeat injections, 45% required no further intervention and 45% underwent or are due for hip replacement. No immediate complications occurred.

Intra-articular hip injection reduced pain in 86% of cases and has delayed any further surgical treatment for at least 2 years in over 50% of OA cases. It is hence a cost-effective treatment modality. Further work is necessary to describe factors predicting response.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 49 - 49
1 Jun 2016
Spiegelberg B Kendrick B Taylor A Stubbs D McLardy-Smith P Gundle R
Full Access

Introduction

Native hip joint infection can result in hip arthrosis as a complication requiring the need for subsequent arthroplasty. There is little evidence to support single or staged THA. We present the results of patients who have undergone total hip arthroplasty (THA) following hip joint sepsis in our institution.

Methods

Patients receiving a THA following previous hip joint sepsis between 2003 and 2015 were identified from the operative records database. Further clinical information was collected from the medical records, including timing of infection and surgery, as well as culture results. Functional outcome (Oxford Hip Score, OHS) and patient satisfaction scores (PSS) were recorded.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 47 - 47
1 Jun 2016
Grammatopoulos G Alvand A Martin H Taylor A Whitwell D Gibbons M
Full Access

The management of proximal femoral bone loss is a significant challenge in revision hip arthroplasty. A possible solution is the use of a modular proximal femur endoprosthesis (EPR). Although the survivorship and functional outcome of megaprostheses used in tumour surgery has been well described, outcome of EPRs used in revision hip surgery has received less attention. The aim of this study was to determine the 5-year outcome following proximal femur EPR and determine factors that influence it.

This was a retrospective consecutive case series of all EPRs (n=80) performed for non-neoplastic indications, by 6 surgeons, in our tertiary referral centre, between 2005–2014. Patient demographics and relevant clinical details were determined from notes. The most common indications for the use of EPRs included infection (n=40), peri-prosthetic fracture (n=12) and failed osteosynthesis of proximal femoral fractures/complex trauma (n=11). Outcome measures included complication and re-operation rates, implant survival and assessment of functional outcome using the Oxford-Hip-Score (OHS).

The mean age at surgery was 69 years and mean follow-up was 4 (0 – 11) years. The mean number of previous hip operations was 2.4 (range: 0 – 17). Twenty-five patients sustained a complication (31%), the most common being infection (n=9) and dislocation (n=4). By follow-up, further surgery was required in 18 (22%) hips, 9 of which were EPR revisions. 5-yr implant survivorship was 87% (95%CI: 76 – 98%). Mean OHS was 28 (range: 4 – 48). Inferior survival and outcome were seen in EPRs performed for the treatment of infection. Infection eradication was achieved in 34/41 with the index EPR procedure and in 40/41 hips by follow-up.

Limb salvage was achieved in all cases and acceptable complication- and re-operation rates were seen. EPRs for periprosthetic fractures and failed osteosynthesis had best outcome. We recommend the continued use of proximal femur EPR in complex revision surgery.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 52 - 52
1 Jun 2016
Grammatopoulos G Kendrick B Glyn-Jones S McLardy-Smith P Taylor A Gundle R
Full Access

Introduction

The value of Debridement-Antibiotics-and-Implant-Retention (DAIR) in prosthetic-joint-infection (PJI) is still a matter of debate as most studies to-date are underpowered with variable end-points. In our, tertiary referral, bone infection unit we consider DAIR to be a suitable option in all PJIs with soundly fixed prostheses, despite chronicity. The aims of this study were to define the long-term outcome following DAIR in hip PJI and identify factors that influence it.

Methods

This is a retrospective consecutive case series of DAIRs performed between 1997 and 2013. Only infected cases confirmed by established criteria were included. Data recorded included patient demographics, medical history (ASA grade, Charlson and KLICC scores), type of surgery performed (DAIR or DAIR + exchange of modular components) and organism grown. Outcome measures included complications, implant survivorship and functional outcome (Oxford Hip Score, OHS).


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 37 - 37
1 Dec 2015
Brent A Barrett L Dudareva M Figtree M Colledge R Newnham R Bejon P Mcnally M Taylor A Atkins B
Full Access

Collection of 4–5 independent peri-prosthetic tissue samples is recommended for microbiological diagnosis of prosthetic joint infections. Sonication of explanted prostheses has also been shown to increase microbiological yield in some centres. We compared sonication with standard tissue sampling for diagnosis of prosthetic joint and other orthopaedic device related infections.

We used standard protocols for sample collection, tissue culture and sonication. Positive tissue culture was defined as isolation of a phenotypically indistinguishable organism from ≥2 samples; and positive sonication culture as isolation of an organism at ≥50 cfu/ml. We compared the diagnostic performance of each method against an established clinical definition of infection (Trampuz 2011), and against a composite clinical and microbiological definition of infection based on international consensus (Gehrke & Parvizi 2013).

350 specimens were received for sonication, including joint prostheses (160), exchangeable components (76), other orthopaedic hardware and cement (104), and bone (10). A median of 5 peri-prosthetic tissue samples were received from each procedure (IQR 4–5). Tissue culture was more sensitive than sonication for diagnosis of prosthetic joint and orthopaedic device related infection using both the clinical definition (66% versus 57%, McNemar's Χ2 test p=0.016) and the composite definition of infection (87% vs 66%, p<0.001). The combination of tissue culture and sonication provided optimum sensitivity: 73% (95% confidence interval 65–79%) against the clinical definition and 92% (86–96%) against the composite definition.

Results were similar when analysis was confined to joint prostheses and exchangeable components; other orthopaedic hardware; and patients who had received antibiotics within 14 days prior to surgery.

Tissue sampling appears to have higher sensitivity than sonication for diagnosis of prosthetic joint and orthopaedic device infection at our centre. This may reflect rigorous collection of multiple peri-prosthetic tissue samples. A combination of methods may offer optimal sensitivity, reflecting the anatomical and biological spectrum of prosthetic joint and other device related infections.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 72 - 72
1 Dec 2015
Grammatopoulos G Kendrick B Athanasou N Byren I Atkins B Mcnally M Mclardy-Smith P Gundle R Taylor A
Full Access

Debridement, antibiotics and implant retention (DAIR) is a surgical option in the treatment of prosthetic joint infection (PJI). It is thought to be most appropriate in the treatment of early (≤6 weeks post-op) PJI. Most studies to-date reporting on DAIRs in hip PJI have been underpowered by reporting on small cohorts (n= <45), or report on registry data with associated biases and limitations. In our, tertiary referral, bone infection unit we consider DAIR to be a suitable option in all cases of PJI with a soundly fixed prosthesis, with early or late presentation, especially in patients who are too elderly or infirm to undergo major surgery.

Aim: To define the 10-year outcome following DAIR in hip PJI and identify factors that influence it.

We retrospectively reviewed all DAIRs performed in our unit between 1997 and 2013 for hip PJI. Only infected cases confirmed by histological and microbiological criteria were included. Data recorded included patient demographics and medical history, type of surgery performed (DAIR or DAIR + exchange of modular components), organism identified and type/duration of antibiotic treatment. Outcome measures included complications, mortality rate, implant survivorship and functional outcome.

121 DAIRs were identified with mean age of 71 years (range: 33–97). 67% followed an index procedure of 1° arthroplasty. 53% included exchange of modular components. 60% of DAIRs were for early onset PJI. Isolated staphylococcus was present in 50% of cases and 25% had polymicrobial infection. At follow-up (mean:7 years, range: 0.3 – 18), 83 patients were alive; 5- and 10- year mortality rates were 15% and 35% respectively. 45% had a complication (persistence of infection: 27%, dislocation: 10%) and 40% required further surgery. Twenty hips have been revised to-date (17%). Performing a DAIR and not exchanging the modular components was associated with an almost 3× risk (risk ratio: 2.9) of subsequent implant failure (p=0.04). 10-yr implant survivorship was 80% (95%CI: 70 – 90%). Improved 10-year implant survivorship was associated with DAIR performed for early PJI (85% Vs 68%, p=0.04). Functional outcome will be discussed.

DAIR is a particularly valuable option in the treatment of hip PJI, especially in the early post-operative period. Whenever possible, exchange of modular implants should be undertaken, however DAIRs are associated with increased morbidity even in early PJI. Factors that predict success of DAIR in late PJI need to be identified.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1031 - 1037
1 Aug 2015
da Assunção RE Pollard TCB Hrycaiczuk A Curry J Glyn-Jones S Taylor A

Periprosthetic femoral fracture (PFF) is a potentially devastating complication after total hip arthroplasty, with historically high rates of complication and failure because of the technical challenges of surgery, as well as the prevalence of advanced age and comorbidity in the patients at risk.

This study describes the short-term outcome after revision arthroplasty using a modular, titanium, tapered, conical stem for PFF in a series of 38 fractures in 37 patients.

The mean age of the cohort was 77 years (47 to 96). A total of 27 patients had an American Society of Anesthesiologists grade of at least 3. At a mean follow-up of 35 months (4 to 66) the mean Oxford Hip Score (OHS) was 35 (15 to 48) and comorbidity was significantly associated with a poorer OHS. All fractures united and no stem needed to be revised. Three hips in three patients required further surgery for infection, recurrent PFF and recurrent dislocation and three other patients required closed manipulation for a single dislocation. One stem subsided more than 5 mm but then stabilised and required no further intervention.

In this series, a modular, tapered, conical stem provided a versatile reconstruction solution with a low rate of complications.

Cite this article: Bone Joint J 2015;97-B:1031–7.


Bone & Joint Research
Vol. 3, Issue 11 | Pages 321 - 327
1 Nov 2014
Palmer AJR Ayyar-Gupta V Dutton SJ Rombach I Cooper CD Pollard TC Hollinghurst D Taylor A Barker KL McNally EG Beard DJ Andrade AJ Carr AJ Glyn-Jones S

Aims

Femoroacetabular Junction Impingement (FAI) describes abnormalities in the shape of the femoral head–neck junction, or abnormalities in the orientation of the acetabulum. In the short term, FAI can give rise to pain and disability, and in the long-term it significantly increases the risk of developing osteoarthritis. The Femoroacetabular Impingement Trial (FAIT) aims to determine whether operative or non-operative intervention is more effective at improving symptoms and preventing the development and progression of osteoarthritis.

Methods

FAIT is a multicentre superiority parallel two-arm randomised controlled trial comparing physiotherapy and activity modification with arthroscopic surgery for the treatment of symptomatic FAI. Patients aged 18 to 60 with clinical and radiological evidence of FAI are eligible. Principal exclusion criteria include previous surgery to the index hip, established osteoarthritis (Kellgren–Lawrence ≥ 2), hip dysplasia (centre-edge angle < 20°), and completion of a physiotherapy programme targeting FAI within the previous 12 months. Recruitment will take place over 24 months and 120 patients will be randomised in a 1:1 ratio and followed up for three years. The two primary outcome measures are change in hip outcome score eight months post-randomisation (approximately six-months post-intervention initiation) and change in radiographic minimum joint space width 38 months post-randomisation. ClinicalTrials.gov: NCT01893034.

Cite this article: Bone Joint Res 2014;3:321–7.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 876 - 883
1 Jul 2014
Grammatopoulos G Pandit HG da Assunção R Taylor A McLardy-Smith P De Smet KA Murray DW Gill HS

The orientation of the acetabular component is influenced not only by the orientation at which the surgeon implants the component, but also the orientation of the pelvis at the time of implantation. Hence, the orientation of the pelvis at set-up and its movement during the operation, are important. During 67 hip replacements, using a validated photogrammetric technique, we measured how three surgeons orientated the patient’s pelvis, how much the pelvis moved during surgery, and what effect these had on the final orientation of the acetabular component. Pelvic orientation at set-up, varied widely (mean (± 2, standard deviation (sd))): tilt 8° (2sd ±32), obliquity –4° (2sd ±12), rotation –8° (2sd ±14). Significant differences in pelvic positioning were detected between surgeons (p < 0.001). The mean angular movement of the pelvis between set-up and component implantation was 9° (sd 6). Factors influencing pelvic movement included surgeon, approach (posterior >  lateral), procedure (hip resurfacing > total hip replacement) and type of support (p < 0.001). Although, on average, surgeons achieved their desired acetabular component orientation, there was considerable variability (2sd ±16) in component orientation. We conclude that inconsistency in positioning the patient at set-up and movement of the pelvis during the operation account for much of the variation in acetabular component orientation. Improved methods of positioning and holding the pelvis are required.

Cite this article: Bone Joint J 2014; 96-B:876–83.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 12 - 12
1 Jan 2014
Salar O Shivji F Holley J Choudhry B Taylor A Moran C
Full Access

Introduction:

We report our 10-year experience of post-operative complications of calcaneal fractures treated by internal fixation and attempt to correlate these with previously cited patient risk factors.

Methods:

All calcaneal fractures treated by internal fixation in our Major Trauma Centre between September 2002 and September 2012 were identified. Patient indices (age, gender, smoking status and pre-existing co-morbidities), time to surgery and method of surgery (open reduction and internal fixation (ORIF) versus closed reduction and percutaneous fixation) were recorded. Primary outcome was the incidence of wound infection requiring intravenous antibiotics and/or re-operation. Statistical analysis through Mann-Whitney-Wilcoxon testing and relative risk ratio calculations with 95% Confidence Intervals (CI) was performed.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 33 - 33
1 Jan 2014
Raglan M Taylor A Dhar S
Full Access

Introduction:

Total ankle replacement is a recognised treatment for disabling end stage ankle arthritis and an alternative to arthrodesis, although results are not yet comparable to other joint replacements. This has stimulated a constant evolution in design of implants and instrumentation. The Nottingham Foot and Ankle Unit used the STAR until 2005, when it switched to Mobility, due to the perceived advantages of less bone resection, improved instrumentation and potentially less polyethylene insert wear. The aim of this study is to report the unit's results and review the different outcomes between the two ankle replacements used.

Methods:

A retrospective analysis of all total ankle replacements carried out by the foot and ankle unit at Nottingham City Hospital between March 1999 and June 2013. Post operative complications, associated reoperations and revisions were recorded. The American Orthopaedic Foot and Ankle Score (AOFAS), Foot Function Index (FFI), European five dimension quality of life scores (EQ-D5) and patient satisfaction was independently assessed at each follow up visit. Other ankle replacements or those performed elsewhere or with less than 12 month follow up were excluded.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 11 - 11
1 Jan 2014
Salar O Shivji F Holley J Choudhry B Taylor A Moran C
Full Access

Introduction:

Calcaneal fractures are rare but debilitating injuries assumed to affect particular demographic sub groups. This study aimed to relate epidemiological factors (age, gender, smoking status and social deprivation scores) to the incidence of calcaneal fractures requiring operative fixation over a 10-year period.

Methods:

Data (age, gender and smoking status) was extracted from a prospective trauma database regarding calcaneal fractures between September 2002 and September 2012. The Rank of Index of Multiple Deprivation (IMD) scores was collated for each patient and data sub-stratified in 20% centiles. 2010 National Census Data was used to formulate patient subgroups and incidences. Resulting data was subjected to statistical analysis through calculation of relative risk (RR) scores with 95% confidence intervals (95% CI).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 286 - 286
1 Dec 2013
Dickinson A Taylor A Roques A Browne M
Full Access

Introduction:

Novel biomaterials may offer alternatives to metal arthroplasty bearings. To employ these materials in thin, bone conserving implants would require direct fixation to bone, using Titanium/HA coatings. Standard tests are used to evaluate the adhesion strength of coatings to metal substrates [1], versus FDA pass criteria [2]. In tensile adhesion testing, a disc is coated and uniform, uniaxial tension is exerted upon the coating-substrate interface; the strength is calculated from the failure load and surface area. Rapid failure occurs when the peak interface stress exceeds the adhesion strength, as local failure will propagate into an increasing tensile stress field.

Ceramics and reinforced polymers (e.g. carbon-fibre-reinforced PEEK), have considerably different stiffness (E) and Poisson's Ratio (ν) from the coating and implant metals. We hypothesised that this substrate-coating stiffness mismatch would produce stress concentrations at the interface edge, well in excess of the uniform stress experienced with coatings on similar stiffness metals.

Methodology:

The interface tensile stress field was predicted for the ASTM F1147 tensile strength test with a finite element analysis model, with a 500 μm thick coating (50 μm dense Ti layer, 450 μm porous Ti/HA/adhesive layer), bonded to a stainless steel headpiece with FM1000 adhesive (Fig. 1). Solutions were obtained for:

Configuration A: ASTM-standard geometry with Ti-6Al-4V (E = 110GPa, ν = 0.31), CoCrMo (E = 196GPa, ν = 0.30), ceramic (E = 350GPa, ν = 0.22, e.g. BIOLOX delta) and CFR-PEEK (E = 15GPa, ν = 0.41, e.g. Invibio MOTIS) substrates.

Modified models were used to analyse oversized substrate discs:

Configuration B: coated fully and bonded to the standard diameter headpiece, and

Configuration C: Coated only where bonded to the headpiece.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 166 - 166
1 Mar 2013
Dickinson A Taylor A Roques A Browne M
Full Access

Representative pre-clinical analysis is essential to ensure that novel prosthesis concepts offer an improvement over the state-of-the-art. Proposed designs must, fundamentally, be assessed against cyclic loads representing common daily activities [Bergmann 2001] to ensure that they will withstand conceivable in-vivo loading conditions. Fatigue assessment involves:

cyclic mechanical testing, representing worst-case peak loads encountered in-vivo, typically for 10 million cycles, or

prediction of peak fatigue stresses using Finite Element (FE) methods, and comparison with the material's endurance limit.

Cyclic stresses from gait loading are super-imposed upon residual assembly stresses. In thick walled devices, the residual component is small in comparison to the cyclic component, but in thin section, bone preserving devices, residual assembly stresses may be a multiple of the cyclic stresses, so a different approach to fatigue assessment is required.

Modular devices provide intraoperative flexibility with minimal inventories. Components are assembled in surgery with taper interfaces, but resulting residual stresses are variable due to differing assembly forces and potential misalignment or interface contamination. Incorrect assembly can lead to incomplete seating and dissociation [Langdown 2007], or fracture due to excessive press-fit stress or point loading [Hamilton 2010]. Pre-assembly in clean conditions, with reproducible force and alignment, gives close control of assembly stresses. Clinical results indicate that this is only a concern with thick sectioned devices in a small percentage of cases [Hamilton 2010], but it may be critical for thin walled devices.

A pre-clinical analysis method is proposed for this new scenario, with a case study example: a thin modular cup featuring a ceramic bearing insert and a Ti-6Al-4V shell (Fig. 1). The design was assessed using FE predictions, and manufacturing variability from tolerances, surface finish effects and residual stresses was assessed, in addition to loading variability, to ensure physical testing is performed at worst case:

assembly loads were applied, predicting assembly residual stress, verified by strain gauging, and a range of service loads were superimposed.

The predicted worst-case stress conditions were analysed against three ‘constant life’ limits [Gerber, 1874, Goodman 1899, Soderberg 1930], a common aerospace approach, giving predicted safety factors. Finally, equivalent fatigue tests were conducted on ten prototype implants.

Taking a worst-case size (thinnest-walled 48 mm inner/58 mm outer), under assembly loading the peak tensile stress in the titanium shell was 274 MPa (Fig. 2). With 5kN superimposed jogging loading, at an extreme 75° inclination, 29 MPa additional tensile stress was predicted. This gave mean fatigue stress of 288.5 MPa and stress amplitude of 14.5 MPa (R=0.9). Against the most conservative infinite life limit (Soderberg), the predicted safety factor was 2.40 for machined material, and 2.03 for forged material, or if a stress-concentrating surface scratch occurs during manufacturing or implantation (Fig. 3). All cups survived 10,000,000 fatigue cycles.

This study employed computational modelling and physical testing to verify the strength of a joint prosthesis concept, under worst case static and fatigue loading conditions. The analysis technique represents an improvement in the state of the art where testing standards refer to conventional prostheses; similar methods could be applied to a wide range of novel prosthesis designs.


Bone & Joint Research
Vol. 2, Issue 2 | Pages 33 - 40
1 Feb 2013
Palmer AJR Thomas GER Pollard TCB Rombach I Taylor A Arden N Beard DJ Andrade AJ Carr AJ Glyn-Jones S

Objectives

The number of surgical procedures performed each year to treat femoroacetabular impingement (FAI) continues to rise. Although there is evidence that surgery can improve symptoms in the short-term, there is no evidence that it slows the development of osteoarthritis (OA). We performed a feasibility study to determine whether patient and surgeon opinion was permissive for a Randomised Controlled Trial (RCT) comparing operative with non-operative treatment for FAI.

Methods

Surgeon opinion was obtained using validated questionnaires at a Specialist Hip Meeting (n = 61, 30 of whom stated that they routinely performed FAI surgery) and patient opinion was obtained from clinical patients with a new diagnosis of FAI (n = 31).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 96 - 96
1 Jan 2013
Palmer A Thomas G Whitwell D Taylor A Murray D Price A Arden N Glyn-Jones S
Full Access

Introduction

Hip arthroscopy is a relatively new procedure and evidence to support its use remains limited. Well-designed prospective clinical trials with long-term outcomes are required, but study design requires an understanding of current practice. Our aim was to determine temporal trends in the uptake of non-arthroplasty hip surgery in England between 2001 and 2011.

Methods

Using procedure and diagnosis codes, we interrogated the Hospital Episode Statistics (HES) Database for all hip procedures performed between 2001 and 2011, excluding those relating to arthroplasty, tumour or infection. Osteotomy procedures were also excluded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 247 - 247
1 Sep 2012
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R Mclardy-Smith P Gill H Murray D
Full Access

Introduction

Since the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA), thousands of such prostheses have been implanted worldwide in younger patients with end-stage hip osteoarthritis. However, no independent centre has reported their medium-to-long term outcome. The aim of this study is to report the ten year survival and outcome of the Birmingham Hip Resurfacing (BHR), the most commonly used MoMHRA worldwide.

Methods

Since 1999, 648 BHRs were implanted in 555 patients, the majority of which were male (326). The mean age at surgery was 52.1years (range: 17–82), with primary OA as most common indication (85%). Mean follow up was 7.1years (range: 1–11). The Oxford Hip Score (OHS) and UCLA questionnaires were sent to all patients. Implant survival was established, with revision as the end point. Sub-analysis was performed by gender, femoral component size (small: <45mm, standard: 46–52, large: >53mm) and age at surgery (young:<50yrs, old:>50yrs).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 49 - 49
1 Sep 2012
Dickinson A Taylor A Browne M
Full Access

INTRODUCTION

Resurfacing prostheses are implanted by impaction onto the prepared femoral head. Ceramic resurfacings can be proposed as an alternative to metal implants, combining bone conservation with mitigation of sensitivity reaction risks. With low wall-thickness required for bone conservation, their strength must be verified. This study aimed to assess a ceramic resurfacing prosthesis' strength under surgical loads using a computational model, tuned and verified with physical tests.

METHODS

Tests were conducted to obtain baseline impact data (Fig1 left). Ø58mm DeltaSurf prostheses (Finsbury Development Ltd., UK), made from BIOLOX Delta (CeramTec AG, Germany) ceramic were cemented onto 40pcf polyurethane foam stubs (Sawbone AG, Sweden) attached to a load cell (Instron 8874, Instron Corp., USA). Ten repeatable 2ms−1 slide hammer impacts were applied with a 745g mass. The reaction force at the bone stub base was recorded, and the cumulative impulse was calculated by integrating reaction force over time.

A half-plane symmetry model was developed using LS-DYNA (ANSYS Inc., USA) explicit dynamic FE analysis software (Fig1, right). The bone stub was constrained, and the mallet was given an initial velocity of 2.0m/s. Outputs were the impact reaction force at the bone stub base, the impact duration and the peak tensile prosthesis stress.

First, the model was solved representing the experimental setup, to fit damping parameters. Then the damped model was used to predict the peak prosthesis stresses under more clinically representative loads from a 990g mallet. The smallest (Ø40mm) and largest (Ø58mm) prosthesis heads in the size range were analysed, with two impact directions: along the prosthesis axis, and with the impactor inclined at 10°.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 75 - 75
1 May 2012
Bayley E Duncan N Taylor A
Full Access

Introduction

Comminuted mid-foot fractures are uncommon. Maintenance of the length and alignment of the medial column, with restoration of articular surface congruity, is associated with improved outcomes. Conventional surgery has utilised open or closed reduction with K-wire fixation, percutaneous techniques, ORIF, external fixation or a combination of these methods.

In 2003 temporary bridge plating of the medial column was described to reconstruct and stabilise the medial column. The added advantage of locking plates is the use of angle-stable fixation. We present our experience with temporary locking plates in complex mid-foot fractures.

Materials and methods

Prospective audit database of 12 patients over a 6 year period (2003-2009).

5 males 7 females mean age 41.9.

Mechanism of injury: 11 high-energy injuries (6 falls from height, 5 RTCs), 1 low energy injury. Fracture type: All involved the medial column - 12 fracture dislocations of the medial column.

4 concomitant injuries to the lateral column.

All underwent ORIF, realignment, and stabilisation with locking plates across the mid-foot.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 546 - 546
1 Nov 2011
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R McLardy-Smith P Murray D Gill H
Full Access

Introduction: Metal-on-metal-hip-resurfacing-arthroplasty (MoMHRA) has been associated with the development of inflammatory pseudotumours(IP), especially in females. IPs have been linked to wear debris, which can be related to metal-ion blood levels. Acetabular component position has been shown to influence wear. We have identified an optimum component orientation minimising IP risk around an inclination/anteversion of 40°/20°±10°. Our aim was to see if this optimal position results in lower metal ions and to identify the boundary of an optimal placement zone for low wear.

Methods: A cohort of 104 patients(60M:44F) with unilateral MoMHRA was studied. Blood tests were obtained at a mean follow up of 3.9 years and serum Co/Cr levels were measured(ICPMS). High metal ion concentrations were defined as Co> 4.1ppb and Cr> 5.2ppb. Radiographic cup inclination/anteversion were measured using EBRA. The differences in ion levels between different orientation zones were investigated. Three orientation zones were defined centered on 40°/20°: Z1-within ±5°, Z2-outside ±5°/within ±10° and Z3-within ±10°.

Results: There was a wide range of cup placements. Females had significantly (p< 0.001) smaller components(mean:51, 44–60) than males(mean: 56, 52–64). Cr levels, but not Co, were higher in females(p=0.002) and those with small femoral components(< 50mm, p =0.03). Patients with cups within Z1 (n=13) had significantly lower Co(p=0.005) and Cr(p=0.001). Males with cups within Z3(n=27) had lower ion levels in comparison to those outside, which were significantly lower for Co(p=0.049) but not Cr(p=0.084). Females had similar ion levels within and out of Z3(Cr/Co: p=0.83/0.84). Co levels were significantly lower in Z1(n=13) in comparison to Z2(n=33)(p=0.048) but Cr levels were not different (p=0.06).

Discussion: MoMHRA cups placed within ±5° of the optimum(40°/20°) had significantly lower metal ions indicating lower wear within this narrow zone. This safe zone, could extend to ±10° for males only. The narrower safe zone coupled with smaller components implanted are possible factors contributing to the increased IP incidence seen in females.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 547 - 547
1 Nov 2011
Thomas G Simpson D Taylor A Whitwell D Gibbons C Gundle R Mclardy-smith P Gill H Glyn-jones S Murray D
Full Access

Introduction: The use of highly cross-linked polyethylene (HXLPE) is now commonplace for total hip arthroplasty, however there is no long-term data to support its use. Hip simulator studies suggest that the wear rate of some types of HXLPE is ten times less than conventional polyethylene (UHMWPE). The outcomes of hip simulator studies are not always reproduced in vivo and there is some evidence that HXLPE wear may increase between 5 and 7 years.

Method: A prospective double blind randomised control trial was conducted using Radiostereometric Analysis (RSA). Fifty-four subjects were randomised to receive hip replacements with either UHMWPE liners or HXLPE liners. All subjects received a cemented CPT stem and uncemented Trilogy acetabular component (Zimmer, Warsaw, IN, USA). The 3D penetration of the head into the socket was determined to a minimum of 7 years.

Results: The total liner penetration was significantly different at 7 years (p=0.005) with values of 0.33 mm (SE 0.05 mm) for the HXLPE group and 0.55 mm (SE 0.05 mm) for the UHMWPE group. The steady state wear rate from 1 year onwards was significantly lower for HXLPE (0.005 mm/yr, SE 0.007 mm/yr) than for UHMWPE (0.037 mm/yr, SE 0.009 mm/yr) (p=0.007). The direction of wear was supero-lateral.

Discussion: We have previously demonstrated that the penetration in the first year is creep-dominated, from one year onwards the majority of penetration is probably due to wear. This study confirms the predictions from hip simulator studies which suggest that the wear rate of this HXLPE approaches that of metal-on-metal and ceramic-on-ceramic articulations. HXLPE may have the potential to reduce the need of revision surgery, due to wear debris induced osteolysis. It may also enable surgeons to use larger couples, thus reducing the risk of impingement and dislocation.