Abstract

Debridement, antibiotics and implant retention (DAIR) is a surgical option in the treatment of prosthetic joint infection (PJI). It is thought to be most appropriate in the treatment of early (≤6 weeks post-op) PJI. Most studies to-date reporting on DAIRs in hip PJI have been underpowered by reporting on small cohorts (n= <45), or report on registry data with associated biases and limitations. In our, tertiary referral, bone infection unit we consider DAIR to be a suitable option in all cases of PJI with a soundly fixed prosthesis, with early or late presentation, especially in patients who are too elderly or infirm to undergo major surgery.

Aim: To define the 10-year outcome following DAIR in hip PJI and identify factors that influence it.

We retrospectively reviewed all DAIRs performed in our unit between 1997 and 2013 for hip PJI. Only infected cases confirmed by histological and microbiological criteria were included. Data recorded included patient demographics and medical history, type of surgery performed (DAIR or DAIR + exchange of modular components), organism identified and type/duration of antibiotic treatment. Outcome measures included complications, mortality rate, implant survivorship and functional outcome.

121 DAIRs were identified with mean age of 71 years (range: 33–97). 67% followed an index procedure of 1° arthroplasty. 53% included exchange of modular components. 60% of DAIRs were for early onset PJI. Isolated staphylococcus was present in 50% of cases and 25% had polymicrobial infection. At follow-up (mean:7 years, range: 0.3 – 18), 83 patients were alive; 5- and 10- year mortality rates were 15% and 35% respectively. 45% had a complication (persistence of infection: 27%, dislocation: 10%) and 40% required further surgery. Twenty hips have been revised to-date (17%). Performing a DAIR and not exchanging the modular components was associated with an almost 3× risk (risk ratio: 2.9) of subsequent implant failure (p=0.04). 10-yr implant survivorship was 80% (95%CI: 70 – 90%). Improved 10-year implant survivorship was associated with DAIR performed for early PJI (85% Vs 68%, p=0.04). Functional outcome will be discussed.

DAIR is a particularly valuable option in the treatment of hip PJI, especially in the early post-operative period. Whenever possible, exchange of modular implants should be undertaken, however DAIRs are associated with increased morbidity even in early PJI. Factors that predict success of DAIR in late PJI need to be identified.