Results 1 - 50 of 90
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 14 - 14
2 May 2024
Menakaya C Durand-Hill M Carrington R Hart A Donaldson J Miles J Briggs T Skinner J
Full Access

The management of femoral bone loss is challenging during revision hip arthroplasty. In patients with Paprosky grade IIIB and IV defects, obtaining fixation and rotational stability using traditional surgical constructs is difficult. The use of a custom-made internal proximal femoral replacement prostheses has been proposed as a solution in patients, with severe femoral bone stock loss. However, there is a paucity in the literature on their use and long-term outcomes. We report on the clinical and radiological results of our cohort.

We retrospectively reviewed all patients who underwent internal proximal femoral replacement for revision hip arthroplasty between April 1996 and April 2019. All patients had at least 2 years of follow-up time.

160 patients underwent limb salvage at our institution using internal proximal femoral replacement. The mean follow-up was 79.7 months (S.D 41.3). Indications for revision included periprosthetic fractures, aseptic loosening, and deep infection. The mean Oxford hip score increased from 13.8 (0–22) to 31.5 (18–43) (paired t-test, p < 0.001). Kaplan-Meier prosthesis survival analysis with revision as the endpoint was 87% at 5 years. None required revision of the femoral stem. There were four dislocations (5%) and there was failure to eradicate the deep infection in four.

This technique allows instant distal fixation, allowing for early mobilisation. Long-term clinical and radiological outcomes are encouraging and the complication rates are acceptable for this patient group.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 36 - 36
7 Jun 2023
Hothi H Henckel J Di Laura A Skinner J Hart A
Full Access

3D printing acetabular cups offers the theoretical advantage of enhanced bony fixation due to greater design control of the porous implant surfaces. Analysing retrieved 3D printed implants can help determine whether this design intent has been achieved.

We sectioned 14 off-the-shelf retrieved acetabular cups for histological analysis; 7 cups had been 3D printed and 7 had been conventionally manufactured. Some of the most commonly used contemporary designs were represented in both groups, which were removed due to either aseptic loosening, unexplained pain, infection or dislocation. Clinical data was collected for all implants, including their age, gender, and time to revision.

Bone ingrowth was evaluated using microscopic assessment and two primary outcome measures: 1) bone area fraction and 2) extent of bone ingrowth.

The additively manufactured cups were revised after a median (IQR) time of 24.9 months (20.5 to 45.6) from patients with a median (IQR) age of 61.1 years (48.4 to 71.9), while the conventional cups had a median (IQR) time to revision of 46.3 months (34.7 to 49.1, p = 0.366) and had been retrieved from patients with a median age of 66.0 years (56.9 to 68.9, p = 0.999).

The additively and conventionally manufactured implants had a median (IQR) bone area fraction of 65.7% (36.4 to 90.6) and 33.9% (21.9 to 50.0), respectively (p < 0.001).

A significantly greater amount of bone ingrowth was measured into the backside of the additively manufactured acetabular cups, compared to their conventional counterparts (p < 0.001). Bone occupied a median of 60.0% and 5.7% of the porous depth in the additively manufactured and conventional cups, respectively.

3D printed components were found to achieve a greater amount of bone ingrowth than their conventionally manufactured counterparts, suggesting that the complex porous structures generated through this manufacturing technique may encourage greater osteointegration.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 27 - 27
7 Jun 2023
Hothi H Henckel J Di Laura A Schlueter-Brust K Hart A
Full Access

3D printing is rapidly being adopted by manufacturers to produce orthopaedic implants. There is a risk however of structural defects which may impact mechanical integrity. There are also no established standards to guide the design of bone-facing porous structures, meaning that manufacturers may employ different approaches to this. Characterisation of these variables in final-production implants will help understanding of the impact of these on their clinical performance.

We analysed 12 unused, final-production custom-made 3D printed acetabular cups that had been produced by 6 orthopaedic manufacturers. We performed high resolution micro-CT imaging of each cup to characterise the morphometric features of the porous layers: (1) the level of porosity, (2) pore size, (3) thickness of porous struts and (4) the depth of the porous layers. We then examined the internal cup structures to identify the presence of any defects and to characterise: (1) their total number, (2) volume, (3) sphericity, (4) size and (5) location.

There was a variability between designs in the level of porosity (34% to 85%), pore size (0.74 to 1.87mm), strut thickness (0.28 to 0.65mm), and porous layer depth (0.57 to 11.51mm). One manufacturer printed different porous structures between the cup body and flanges; another manufacturer printed two differing porous regions within the cup body.

5 cups contained a median (range) of 90 (58–101) defects. The median defect volume was 5.17 (1.05–17.33) mm3. The median defect sphericity and size were 0.47 (0.19–0.65) and 0.64 (0.27–8.82) mm respectively. The defects were predominantly located adjacent to screw holes, within flanges and at the transition between the flange and main cup body; these were between 0.17 and 4.66mm from the cup surfaces.

There is a wide variability between manufacturers in the porous titanium structures they 3D print. The size, shape and location of the structural defects identified are such that there may be an increased risk of crack initiation from them, potentially leading to a fracture. Regulators, surgeons, and manufacturers should be aware of this variability in final print quality.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 37 - 37
1 Dec 2022
Moisan P Montreuil J Bernstein M Hart A Tanzer M
Full Access

Although day surgery has a good patient satisfaction and safety profile, accurate episode-of-care costs (EOCC) calculation for of this procedure compared to standard same-day admission (SDA), while considering functional outcomes, is not well known. This study assesses the EOCC for patients with a THA while comparing DS and Same Day Admission (SDA) (with a 1-day hospitalization) pathways.

The episode-of-care cost (EOCC) of 50 consecutive day surgery and SDA patients who underwent a THA was evaluated. The episode-of-care cost was determined using a bottom-up Time Driven- Activity Based Funding method. Functional outcomes were measured using preoperative and postoperative Harris Hip Score (HHS).

Overall, the SDA THA cost 11% more than a DS THA. The mean total EOCC of DS THA was 9 672 CAD compared to 10 911 CAD in the SDA THA group. Both groups showed an improvement in HHS score following the procedure but patients in the DS group had a significantly higher postoperative HHS score and a significantly greater improvement in their HHS score postoperatively.

Day surgery THA is cost-effective, safe and associated with high patient satisfaction due to functional improvement. Providing policymakers the information to develop optimal financing methods is paramount for clinicians wishing to develop modern protocols, increase productivity while providing the optimal care for patients.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 639 - 649
19 Oct 2021
Bergiers S Hothi H Henckel J Di Laura A Belzunce M Skinner J Hart A

Aims

Acetabular edge-loading was a cause of increased wear rates in metal-on-metal hip arthroplasties, ultimately contributing to their failure. Although such wear patterns have been regularly reported in retrieval analyses, this study aimed to determine their in vivo location and investigate their relationship with acetabular component positioning.

Methods

3D CT imaging was combined with a recently validated method of mapping bearing surface wear in retrieved hip implants. The asymmetrical stabilizing fins of Birmingham hip replacements (BHRs) allowed the co-registration of their acetabular wear maps and their computational models, segmented from CT scans. The in vivo location of edge-wear was measured within a standardized coordinate system, defined using the anterior pelvic plane.


Bone & Joint Research
Vol. 10, Issue 7 | Pages 388 - 400
8 Jul 2021
Dall’Ava L Hothi H Henckel J Di Laura A Tirabosco R Eskelinen A Skinner J Hart A

Aims

The main advantage of 3D-printed, off-the-shelf acetabular implants is the potential to promote enhanced bony fixation due to their controllable porous structure. In this study we investigated the extent of osseointegration in retrieved 3D-printed acetabular implants.

Methods

We compared two groups, one made via 3D-printing (n = 7) and the other using conventional techniques (n = 7). We collected implant details, type of surgery and removal technique, patient demographics, and clinical history. Bone integration was assessed by macroscopic visual analysis, followed by sectioning to allow undecalcified histology on eight sections (~200 µm) for each implant. The outcome measures considered were area of bone attachment (%), extent of bone ingrowth (%), bone-implant contact (%), and depth of ingrowth (%), and these were quantified using a line-intercept method.


Bone & Joint Research
Vol. 9, Issue 8 | Pages 515 - 523
1 Aug 2020
Bergiers S Hothi H Henckel J Eskelinen A Skinner J Hart A

Aims

The optimum clearance between the bearing surfaces of hip arthroplasties is unknown. Theoretically, to minimize wear, it is understood that clearances must be low enough to maintain optimal contact pressure and fluid film lubrication, while being large enough to allow lubricant recovery and reduce contact patch size. This study aimed to identify the relationship between diametrical clearance and volumetric wear, through the analysis of retrieved components.

Methods

A total of 81 metal-on-metal Pinnacle hips paired with 12/14 stems were included in this study. Geometrical analysis was performed on each component, using coordinate and roundness measuring machines. The relationship between their as-manufactured diametrical clearance and volumetric wear was investigated. The Mann-Whitney U test and unpaired t-test were used, in addition to calculating the non-parametric Spearman's correlation coefficient, to statistically evaluate the acquired data.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 32 - 32
1 Jul 2020
Horga L Henckel J Fotiadou A Laura AD Hirschmann A Hart A
Full Access

Background

Over 30 million people run marathons annually. The impact of marathon running on hips is unclear with existing literature being extremely limited (only one study of 8 runners).

Aim and Objectives

We aimed to better understand the effect of marathon running on the pelvis and hip joints by designing the largest MRI study of asymptomatic volunteers. The objectives were to evaluate the pelvis and both hip joints before and after a marathon.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 76 - 76
1 Jul 2020
Hart A Rainer W Taunton M Mabry T Berry D Abdel M
Full Access

Patients who are actively smoking at the time of primary total joint arthroplasty (TJA) are at considerably increased risk of perioperative complications. Therefore, strategies to assist patients with smoking cessation before surgery have become routine practice. A secondary benefit is the theoretical catalyst for long-term smoking cessation. However, questions remain as to whether patients actually cease smoking prior to the procedure, and if so, how long this lasts postoperatively.

Our high-volume, academic institution documents self-reported smoking status at each clinic visit (at 6-month intervals), as well as at the time of surgery through a total joint registry. As such, all patients who underwent TJA from 2007 to 2018 were identified and grouped as: non-smokers, smokers (regularly smoking cigarettes within 1 year from surgery), and former smokers (those who quit smoking within a year before surgery). Thereafter, smoking status in the postoperative period was assessed, with special attention to the former smokers in order to see who remained smoke-free.

From the 28,758 primary TJAs identified, 91.3% (26,244) were non-smokers, 7.3% (2,109) were smokers, and 1.4% (405) had quit smoking before surgery. Among patients who quit smoking before surgery, only 38% were still abstinent at 9 years from surgery. Conversely, 24% of smokers at the time of surgery eventually quit and 3.1% of non-smokers started smoking over the same time period.

Despite a concerted effort to help patients stop smoking before TJA, an important proportion (7.3%) are unsuccessful. Among those patients who do manage to stop smoking, only a minority (38%) remain smoke-free after surgery. Compared to current smokers, patients who managed to quit before surgery are more likely to remain smoke-free after surgery. These findings highlight that smoking remains a tremendous challenge in contemporary TJA practices. Additional strategies targeting smoking cessation before after surgery are needed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 24 - 24
1 Jul 2020
Di Laura A Henckel J Belzunce M Hothi H Hart A
Full Access

Introduction

The achieved anteversion of uncemented stems is to a large extent limited by the internal anatomy of the bone. A better understanding of this has recently become an unmet need because of the increased use of uncemented stems.

We aimed to assess plan compliance in six degrees of freedom to evaluate the accuracy of PSI and guides for stem positioning in primary THAs.

Materials and Methods

We prospectively collected 3D plans generated from preoperative CTs of 30 consecutive THAs (17 left and 13 right hips), in 29 patients with OA, consisting of 16 males and 13 females (median age 68 years, range 46–83 years). A single CT-based planning system and cementless type of implant were used.

Post operatively, all patients had a CT scan which was reconstructed using state-of-the-art software solution: the plan and CT reconstruction models were

Outcome measures: 1) discrepancy between planned and achieved stem orientation angles Fig.2&3; 2) clinical outcome.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 130 - 130
1 Feb 2020
Ghaednia H Tallman T Owens C Hart A Varadarajan K
Full Access

INTRODUCTION

Joint replacement is one of the most common orthopaedic procedures, with over 2 million surgeries performed each year across the globe. Loss of implant fixation, or aseptic loosening, is the leading cause of revision following primary joint replacement, accounting for ∼25% of all revision cases [1]. However, diagnosis of aseptic loosening and its underlying causes remain challenging due to the low sensitivity and specificity of plain radiographs. To address this, we propose a novel approach inspired by [2] involving the use of a self-sensing bone cement (by imparting strain-dependent electrical conductivity or piezoresistivity) combined with electrical impedance tomography (EIT). Piezoresistivity is imparted to cement via incorporation of micro/nanoscale conductive fillers. Therefore mechanical effects such as loosening and cracks will manifest as a conductivity change of the cement. This work explores if EIT is able to detect strains and cracks within the bone cement volume.

METHODS

Experiments were designed to determine whether EIT combined with piezoresistive cement can be used to detect strains and cracks (Fig. 1). The setup consists of a tank filled with water, 16 electrodes, sample, a loading machine (MTS), and an EIT system. To develop the piezoresistive bone cement, microscale carbon fibers were used with varying CF/PMMA volumetric ratios (VR) from VR = 0.25% to 3.0%. Three conical samples were made to model a loading condition similar to knee implants (Fig. 1). The samples were compressed while the conductivity map of the tank was measured with the EIT system.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 26 - 26
1 Oct 2019
Taunton MJ Wyles CC Hart A Hevesi M Perry KI Abdel MP Pagnano MW
Full Access

Introduction

There is renewed interest in dislocation after surgical approach with popularization of the direct anterior approach. The purported advantage of both the lateral and direct anterior approaches is decreased risk of dislocation. The purpose of this study was to assess the risk of dislocation by approach following modern primary THA.

Methods

All primary THAs at a single academic institution from 2010 to 2017 were analyzed through our institutional total joint registry. There were 7023 THAs including 3754 posterior, 1732 lateral, and 1537 direct anterior. Risk of dislocation was assessed against the competing risks of revision surgery and death as well as by individual patient and surgical factors including surgical approach. Risk of revision surgery was considered as a secondary outcome. Step-wise selection was utilized to develop multivariable models. Clinical outcomes were documented with the Harris Hip Score (HHS). Mean age was 63 years, 51% were female, and mean body mass index (BMI) was 30 kg/m2. Minimum follow-up was 2 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 31 - 31
1 May 2019
Dall'Ava L Hothi H Di Laura A Henckel J Shearing P Hart A
Full Access

Introduction

Three-dimensional (3D) printing of porous titanium implants marks a revolution in orthopaedics, promising enhanced bony fixation whilst maintaining design equivalence with conventionally manufactured components. No retrieval study has investigated differences between implants manufactured using these two methods. Our study was the first to compare these two groups using novel non-destructive methods.

Materials and methods

We investigated 16 retrieved acetabular cups divided into ‘3D printed’ (n = 6; Delta TT) and ‘conventional’ (n = 10; Pinnacle Porocoat). The groups were matched for age, time to revision, size and gender (Table 1). Reasons for revision included unexplained pain, aseptic loosening, infection and ARMD. Visual inspection was performed to evaluate tissue attachment. Micro-CT was used to assess clinically relevant morphometric features of the porous structure, such as porosity, depth of the porous layer, pore size and strut thickness. Scanning electron microscopy (SEM) was applied to evaluate the surface morphology.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 85 - 85
1 Apr 2019
Dall'Ava L Hothi H Henckel J Cerquiglini A Laura AD Shearing P Hart A
Full Access

Introduction

The use of Additive Manufacturing (AM) to 3D print titanium implants is becoming widespread in orthopaedics, particularly in producing cementless porous acetabular components that are either custom-made or off-the-shelf; the primary design rationale for this is enhanced bony fixation by matching the porosity of bone. Analysis of these retrieved components can help us understand their performance; in this study we introduce a non-destructive method of the retrieval analysis of 3D printed implants.

Material and methods

We examined 11 retrieved 3D printed acetabular cups divided into two groups: “custom-made” (n = 4) and “off-the-shelf” (n = 7). A macroscopic visual analysis was initially performed to measure the area of tissue ongrowth. High resolution imaging of each component was captured using a micro-CT scanner and 3D reconstructed models were used to assess clinically relevant morphometric features of the porous structure: porosity, porous structure thickness, pore size and strut thickness. Optical microscopy was also used as a comparison with microCT results. Surface morphology and elemental composition of the implants were investigated with a Scanning Electron Microscope (SEM) coupled with an Energy Dispersive X-ray Spectroscope (EDS). Statistical analysis was performed to evaluate possible differences between the two groups.


Bone & Joint Research
Vol. 7, Issue 11 | Pages 595 - 600
1 Nov 2018
Bergiers S Hothi HS Henckel J Eskelinen A Skinner J Hart A

Objectives

Previous studies have suggested that metal-on-metal (MoM) Pinnacle (DePuy Synthes, Warsaw, Indiana) hip arthroplasties implanted after 2006 exhibit higher failure rates. This was attributed to the production of implants with reduced diametrical clearances between their bearing surfaces, which, it was speculated, were outside manufacturing tolerances. This study aimed to better understand the performance of Pinnacle Systems manufactured before and after this event.

Methods

A total of 92 retrieved MoM Pinnacle hips were analyzed, of which 45 were implanted before 2007, and 47 from 2007 onwards. The ‘pre-2007’ group contained 45 implants retrieved from 21 male and 24 female patients, with a median age of 61.3 years (interquartile range (IQR) 57.1 to 65.5); the ‘2007 onwards’ group contained 47 implants retrieved from 19 male and 28 female patients, with a median age of 61.8 years (IQR 58.5 to 67.8). The volume of material lost from their bearing and taper surfaces was measured using coordinate and roundness measuring machines. These outcomes were then compared statistically using linear regression models, adjusting for potentially confounding factors.


Bone & Joint Research
Vol. 7, Issue 7 | Pages 476 - 484
1 Jul 2018
Panagiotopoulou VC Davda K Hothi HS Henckel J Cerquiglini A Goodier WD Skinner J Hart A Calder PR

Objectives

The Precice nail is the latest intramedullary lengthening nail with excellent early outcomes. Implant complications have led to modification of the nail design. The aim of this study was to perform a retrieval study of Precice nails following lower-limb lengthening and to assess macroscopical and microscopical changes to the implants and evaluate differences following design modification, with the aim of identifying potential surgical, implant, and patient risk factors.

Methods

A total of 15 nails were retrieved from 13 patients following lower-limb lengthening. Macroscopical and microscopical surface damage to the nails were identified. Further analysis included radiology and micro-CT prior to sectioning. The internal mechanism was then analyzed with scanning electron microscopy and energy dispersive x-ray spectroscopy to identify corrosion.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 39 - 39
1 May 2018
Di Laura A Hothi H Henckel J Skinner J Hart A
Full Access

Introduction

Modular-neck hips have twice the rate of revision compared to fixed stems. Metal related pathology is the second most common reason for revision of implants featuring titanium stems with cobalt chrome necks. We aimed to understand the in-vivo performance of current designs and explore the rationale for their continued use.

Methods

This study involved the examination of 200 retrieved modular-neck hips grouped according to the material used for their neck and stem. Groups A, B and C had neck/stems featuring CoCr/beta Ti-alloy (TMZF), CoCr/Ti6Al4V-alloy, and Ti6Al4V/Ti6Al4V respectively. Reasons for revision included pain, elevated metal ion levels and fluid collection. The stem-neck interface was assessed for severity of fretting/corrosion using metrology methods to compute linear wear penetration rate.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 29 - 29
1 May 2018
Hothi H Eskelinen A Henckel J Blunn G Skinner J Hart A
Full Access

Introduction

Numerous studies have reported on clinically significant volumes of material loss and corrosion at the head-stem junction of metal-on-metal (MOM) hips; less is understood about metal-on-polyethylene (MOP) hips. We compared the effect of bearing type (MOM vs MOP) on taper material loss for a hip system of a single design (DePuy Pinnacle).

Methods

We recruited retrieved MOM (n=30) and MOP (n=22) bearing hips that were consecutively received at our centre.

We prospectively collected associated clinical and imaging data. We measured the severity of corrosion and volumes of material loss at each head taper surface and used multivariate statistical analysis to investigate differences between the two bearing types.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 80 - 80
1 Apr 2018
Sugand K van Duren B Wescott R Carrington R Hart A
Full Access

Background

Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure.

Methods

This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR) were recorded for each attempt.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 81 - 81
1 Apr 2018
Sugand K Wescott R van Duren B Carrington R Hart A
Full Access

Background

Training within surgery is changing from the traditional Halstedian apprenticeship model. There is need for objective assessment of trainees, especially their technical skills, to ensure they are safe to practice and to highlight areas for development. In addition, due to working time restrictions in both the UK and the US, theatre time is being limited for trainees, reducing their opportunities to learn such technical skills. Simulation is one adjunct to training that can be utilised to both assess trainees objectively, and provide a platform for trainees to develop their skills in a safe and controlled environment. The insertion of a dynamic hip screw (DHS) relies on complex psychomotor skills to obtain an optimal implant position. The tip-apex distance (TAD) is a measurement of this positioning, used to predict failure of the implant. These skills can be obtained away from theatre using workshop bone simulation, however this method does not utilise fluoroscopy due to the associated radiation risks. FluoroSim is a novel digital fluoroscopy simulator that can recreate digital radiographs with workshop bone simulation for the insertion of a DHS guide-wire. In this study, we present the training effect demonstrated on FluoroSim. The null hypothesis states that no difference will be present between users with different amounts of exposure to FluoroSim.

Methods

Medical students were recruited from three London universities and randomised into a training (n=23) and a control (n=22) cohort. All participants watched a video explanation of the simulator and task and were blinded to their allocation. Training participants completed 10 attempts in total, 5 attempts in week one, followed by a one week wash out period, followed by 5 attempts in week 2. The control group completed a single attempt each week. For each attempt, 5 metrics were recorded; TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 79 - 79
1 Apr 2018
van Duren B Wescott R Sugand K Carrington R Hart A
Full Access

Background

Hip fractures affect 1.6 million people globally per annum, associated with significant morbidity and mortality. A large proportion are extracapsular neck of femur fractures, treated with the dynamic hip screw (DHS). Mechanical failure due to cut-out is seen in up to 7% of DHS implants. The most important predictor of cut-out is the tip-apex distance (TAD), a numerical value of the lag screw”s position in the femoral head. This distance is determined by the psychomotor skills of the surgeon guided by fluoroscopic imaging in theatre. With the current state of surgical training, it is harder for junior trainees to gain exposure to these operations, resulting in reduced practice. Additionally, methods of simulation using workshop bones do not utilise the imaging component due to the associated radiation risks. We present a digital fluoroscopy software, FluoroSim, a realistic, affordable, and accessible fluoroscopic simulation tool that can be used with workshop bones to simulate the first step of the DHS procedure. Additionally, we present the first round of accuracy tests with this software.

Methods

The software was developed at the Royal National Orthopaedic Hospital, London, England. Two orthogonally placed cameras were used to track two coloured markers attached to a DHS guide-wire. Affine transformation matrices were used in both the anterior-posterior (AP) and cross table lateral (CTL) planes to match three points from the camera image of the workshop bone to three points on a pre-loaded hip radiograph. The two centre points of each marker were identified with image processing algorithms and utilised to digitally produce a line representing the guide-wire on the two radiographs. To test the accuracy of the system, the software generated 3D guide-wire apex distance (GAD) (from the tip of the guide-wire to a marker at the centre of calibration) was compared to the same distance measured with a digital calliper (MGAD). In addition, the same accuracy value was determined in a simulation scenario, from 406 attempts by 67 medical students.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 53 - 53
1 Dec 2017
Henckel J Durand-Hill M Noory S Skinner J Hart A
Full Access

Additive manufacturing has enabled a radical change in how surgeons reconstruct massive acetabular defects in revision hip surgery. We report on the early clinical and radiological results from our methods for surgical planning, design, and implantation of 3D printed trabecular titanium implants in a cohort of patients with large unclassifiable pelvic defects.

We set up a prospective investigation involving 7 consecutive patients. Inclusion criteria was the following: 1) A history of previous total hip replacement; and 2) Current imaging showing at least a Paprosky 3B defect. Planned acetabular inclination and version was 40° and 20° respectively. Post operatively all patients had a CT scan which was analysed with software to determine component position and compared to planned. Outpatient review was done at 2 weeks (For wound), 6 weeks (for weight bearing and fixation) and 52 weeks (for fixation and infection) post-operative.

The median age at surgery was: 65 years (40–78). The median bone defect volume was 140cm3. Median surgery length was 5.2 hours (3–6.25). Median blood loss was 1300mL (450– 2000). Radiologically, components were stable and no screw breakages were identified. Achieved inclination was 41.0° (29.0–55.6) and achieved version was 15.8° (3.8–43.6). Median Oxford Hip score improved from 9 (2–44) to 25 (18–32).

We have demonstrated a new series of pre, intra and post-operative methods for reconstruction of unclassifiable acetabular bony defects. Initial clinical and radiological results are excellent considering the severity of the bony defects. We recommend the use of our or similar methods when trying to reconstruct these defects.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 32 - 32
1 Jun 2017
Di Laura A Hothi H Henckel J Liow M Kwon Y Skinner J Hart A
Full Access

Dual mobility (DM) cups are designed to improve stability, however have been associated with increased risk of impingement that can ultimately result in intraprosthetic dislocation. It is speculated that the femoral neck plays a role in their performance. We investigated the effect of neck topography on the wear of new-generation liners.

This was a retrieval study involving 70 DM cups implanted with liners made of highly crosslinked polyethylene and paired with two neck types: either highly polished (n=35) or rough necks (n=35). The median time of implantation was 30 months.

The rim edge of all inserts was investigated by two examiners for evidence of contact with the femoral neck, presenting as deformation of the polyethylene. A high precision roundness machine and micro-CT scans of the components were used to measure the size of the deformations observed.

28 of the 35 (80%) DM liners paired with rougher necks had evidence of neck impingement resulting in a raised lip, whilst 8 out of 35 (23%) liners paired with smooth necks had a raised lip; this difference was significant (p<0.0001). The repeatability and the inter-observer reproducibility of the deformation scores was found to be substantial κ >0.70. The height of the raised rims of the DM cups paired with rough necks had a median (range) of 139 µm (72–255), whilst had a median (range) of 52 µm (45–90) with smooth necks, the difference between the groups was significant (p<0.0001).

Liner rim deformation resulting from contact with the femoral neck likely begins during early in-vivo function.

Rough necks can increase the damage on the polyethylene rim in dual-mobility bearing, which may lead to loss of the retentive power of these components over time.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 16 - 16
1 Jun 2017
Hothi H Henckel J Shearing P Atrey A Skinner J Hart A
Full Access

Several implants have a proven track record of durability and function in patients over many years. As manufacturers' patents expire it is understandable that cheaper generic copies would be considered. There is currently no established, independent method of determining design equivalence between generic and branded orthopaedic implants.

We acquired 10 boxed, as manufactured components consisting of the generic OptiStem XTR model (n=5) and branded Exeter (n=5) femoral stems. Two examiners were blinded to the implant design and independently measured the mass, volume, trunnion surface topography, roughness, trunnion cone angle, CCD angle and femoral offset using peer-reviewed methods. We then compared the stems using these parameters.

We found that the OptiStems (1) were lighter (p<0.001) (2) had a rougher trunnion surface (p<0.001) with a greater spacing and depth of the machined threads (p<0.001), (3) had greater trunnion cone angles (p=0.007) and (4) a smaller radius at the top of the trunnion (p=0.007). There was no difference for stem volume (p=0.643), CCD angle (p=0.788) or offset (p=0.993).

This study is the first independent investigation of the equivalence of a generic orthopaedic implant to its branded design. We found a clear difference in trunnion roughness, trunnion cone angle and radius, and implant mass when comparing the two generic and branded stem designs. All implants require standard regulatory processes to be followed. It does not appear feasible that generic implants can be manufactured to predictability guarantee the same performance as generic drugs.

We found a number of physical differences between the generic and branded implants. Whilst both designs are likely to work in clinical practice, they are different.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 1 - 1
1 Jun 2017
Panagiotopoulou V Davda K Hothi H Henckel J Cerquiglini A Goodier W Skinner J Hart A Calder P
Full Access

Introduction

The Precice nail is the latest intramedullary lengthening nail with excellent early outcomes. Implant complications have led to modification of the nail design. The aim of this study was to perform a retrieval study of Precice nails following lower limb lengthening. To assess macroscopic and microscopic changes to the implants and assess differences following design modification, with identification of potential surgical, implant and patient risk factors.

Method

15 nails were retrieved from 13 patients following lower limb lengthening. Macroscopic and microscopic surface damage to the nails were identified. Further analysis included radiology and micro-CT prior to sectioning. The internal mechanism was then analysed with Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy to identify corrosion.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 51 - 51
1 Jun 2017
Di Laura A Hothi H Henckel J Liow M Kwon Y Skinner J Hart A
Full Access

Dual-taper implants provide surgeons with options to optimise patients' anatomy intraoperatively but are at risk of early revision due to adverse tissue reactions to corrosion debris. Risk factors for failure and linkage with symptoms however are not fully understood. We related retrieval findings to clinical and implant variables.

This study involved 88 failed dual-taper implants with TMZF femoral stems and cobalt-chromium necks, revised for pain, elevated Co (median = 7.3μg/L) and Cr (median = 2.15μg/L) ions levels and fluid collection on MRI.

Stem-neck surfaces were assessed for: 1) severity of corrosion using a published visual method and 2) severity of material lost and location of damage with a roundness-measuring machine. Five traces were taken on each round section of the taper surface at 45° increments to compute the relative depth of damage. The total area of these traces provided a measure of surface damage for comparative purposes.

The stem-neck taper junctions were severely corroded; the deepest areas of damage were on the inferior-proximal and superior-distal part of the necks, compatible with cantilever bending. Elemental analysis revealed chromium rich deposits indicative of corrosion processes and metal transfer from the stem to the neck.

There was a positive correlation between the severity of damage and time of implantation (p<0.0001). Co and Cr levels in the blood were also strongly correlated (p<0.0001, p=0.0002). No other implant or patient variables were linked.

The stem-neck junction was severely corroded in all cases. The severity and location of the areas of surface damage did not link with implant or patient characteristics in this big cohort suggesting that the design and material combination is the predominant source of failure in these designs.

Dual-taper hips are severely corroded at the stem-neck junction; this appears to be due to the use of a TMZF alloy stem paired with CoCrMo necks.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 9 - 9
1 Jun 2017
Hothi H Duncan C Garbuz D Henckel J Skinner J Hart A
Full Access

Trunnionosis, due to mechanical wear and/or corrosion at the head stem taper junction, can occur in metal on polyethylene (MOP) hip implants. In some patients this results in severe soft tissue destruction or Adverse Reaction to Metal Debris (ARMD). The amount of material required to cause ARMD is unknown but analyses of retrieved hips may provide the answer to this clinically important question.

We collected implants from 20 patients with failed hips with MOP bearings, revised due to ARMD. We collected clinical, imaging and blood test data. We graded the severity of taper corrosion (1 to 4), and quantified the volume of material loss from this junction. We compared our results with previous data collected for metal-on-metal (MOM) hips.

The median time to revision of the MOP hips was 51.3 (23.1–56.4) months. All head tapers were moderately to severely corroded with a median corrosion score of 4. The median (range) of total material loss at the taper of the MOP hips was 3.9 mm3 (2.96 – 7.85 mm3) and the material loss rate was 1.4 mm3 / year (0.56 – 1.82).

Comparison with MOM hips revealed no significant difference in taper material loss (p=0.7344) with a median rate of 0.81 mm3 / year (0.01–3.45).

We are the first to quantify the volume of material loss at the head taper of hip implants with MOP bearings that were revised due to trunnionosis. This data indicates that a clinically significant dose of cobalt and chromium to induce ARMD is approximately 1.4 mm3 / year.

We have identified a clinically significant volume of taper material loss in MOP hips.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 7 - 7
1 Jun 2017
Berber R Abdel-Gadir A Palla L Moon J Manisty C Skinner J Hart A
Full Access

Circulating cobalt and chromium from metal-on-metal implants cause rare but fatal autopsy-diagnosed cardiotoxicity. Concern exists that milder cardiotoxicity may be common and under-recognized. Unacceptably high failure rates of metal-on-metal hip implants have prompted regulatory authorities to issue worldwide safety alerts. Despite this, approximately 1 million patients continue to live with metal-on-metal implants, putting them at risk of systemic toxicity. Although blood cobalt and chromium levels are easily measured and track local toxicity, no non-invasive tests for organ deposition exist.

We recently demonstrated the utilisation of a T2* protocol (cardiovascular MRI) to detect cobalt and chromium deposition within the liver of a patient with elevated blood cobalt levels (confirmed by liver biopsy tissue analysis and X-ray fluorescence spectroscopy).

We sought to detect and constrain the correlation between blood metal ions and a comprehensive panel of established markers of early cardiotoxicity. In addition we applied T2* protocols with the aim of detecting cardiac metal deposition.

90 patients were recruited through RNOH clinics into this prospective single centre blinded study. Patients were divided into 3 age and gender-matched groups according to type of implant and blood metal ion levels as follows: [Group A] Non-metal bearing hip implants; [Group B] Metal-on-metal implants, low blood metal ion levels (<7ppb); and [Group C] Metal-on-metal implants, high blood levels (>7ppb).

All underwent detailed cardiovascular phenotyping using cardiac MRI (with T2*, T1 and ECV mapping, in addition to LV size and ejection fraction), advanced echocardiography (LV size and ejection fraction), and cardiac blood biomarker (Troponin and BNP) sampling in the same sitting at the Heart Hospital London. Primary outcomes were pre-specified. See study flow diagram – figure 1. (The study was registered with clinicaltrials.gov: NCT02331264).

Blood cobalt levels were significantly different between groups (0.17ppb (range 0·10–0·47, SD 0·08) vs. 2·47 (0·72–6·9, SD 1·81) vs. 30·0 (7·54–118.0, SD 29·1) respectively for groups A, B and C).

No significant between-group differences were found for LV size, ejection fraction (CMR or echocardiography), LA size, T1, T2*, ECV, BNP or troponin, with all results within normal ranges. There was no relationship between blood cobalt levels and either left ventricular ejection fraction or T2* (r=-0·022 and r=-0·108 respectively). Although small, the study was sufficiently powered to detect, as a minimum, a difference in ejection fraction of 4.8% (Cohen's d effect size 0·8).

Using best available technologies, exposure of patients with metal-on-metal hip implants to high (but not extreme) blood cobalt and chromium levels has no detectable effect on the heart. We believe these findings will offer reassurance to one million patients worldwide living with a metal-on-metal hip implant and will support clinicians caring for such patients.

For any figures or tables, please contact the authors directly by clicking on ‘Info & Metrics’ above to access author contact details.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 10 - 10
1 Jun 2017
Di Laura A Quinn P Hothi H Henckel J Mosselmans F Skinner J Hart A
Full Access

Total hip arthroplasties are known to corrode predominantly at the taper junctions between Cobalt Chromium Molybedenum (CoCrMo) and Titanium (Ti) alloy components.

We aimed to understand the modes underlying clinically significant tissue reactions to metals from corroded implants by determining: (1) what type of metal is present in the tissues, (2) which cells contain the metal species and (3) how this compares with results from metal-on-metal (MOM) hip resurfacings (HRs).

This study involved periprosthetic tissue from patients that had undergone revision surgery due to adverse reactions to metal debris (ARMD) from dual-taper prostheses consisting of Ti-based alloy stems paired with CoCrMo necks. We used Synchrotron micro X-ray Fluorescence Spectroscopy (µXRF) and micro X-ray Absorption Near Edge Spectroscopy (µXANES) for detection of Co, Cr and Ti, and determination of their oxidation state.

Synchrotron radiation has shown that the chromium in tissues is Cr2O3 when derived from corroded CoCrMo/Ti junctions beside the CrPO4 species found when hip implants release CoCrMo nanoparticles from their bearing surfaces (MoM HRs). Presence of Cr2O3 was associated with titanium oxide TiO2. This may be the outcome of the chemical interaction between the two species. Histological examination showed corrosion products present within viable macrophages and in the extracellular connective tissue, Figure 1.

Understanding corrosion at taper junctions and the pathogenesis of the biological response is of significant clinical importance. This is the first study to co-register histology and metal distribution maps and to explore the potential synergy effect of CoCrMo with Ti alloy.

This study provides guidance for toxicological studies on wear/corrosion particles, how they stimulate the host response and the cellular mechanisms involved in the pathogenesis of ARMD.

For any figures or tables, please contact the authors directly by clicking on ‘Info & Metrics’ above to access author contact details.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 310 - 316
1 Mar 2017
Hothi H Henckel J Shearing P Holme T Cerquiglini A Laura AD Atrey A Skinner J Hart A

Aims

The aim of this study was to compare the design of the generic OptiStem XTR femoral stem with the established Exeter femoral stem.

Materials and Methods

We obtained five boxed, as manufactured, implants of both designs at random (ten in total). Two examiners were blinded to the implant design and independently measured the mass, volume, trunnion surface topography, trunnion roughness, trunnion cone angle, Caput-Collum-Diaphyseal (CCD) angle, femoral offset, stem length, neck length, and the width and roughness of the polished stem shaft using peer-reviewed methods. We then compared the stems using these parameters.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 12 - 12
1 Feb 2017
Hart A Henckel J
Full Access

Background

Surgeons are waiting for a hassle free, time saving, precise and accurate guide for hip arthroplasty. Industry are waiting for instruments to reduce manufacturing costs associated with washing, assembling, sterilization and transportation. Patient specific / custom made surgical guides may deliver these goals but current systems have had limited assessments.

We comprehensively assessed a new guiding system for the acetabular component of hip replacement, “Bullseye”.

Methods

Planning. We used either Computer Tomography (CT) (n=22) or Magnetic Resonance (MR) (n=6) imaging to plan the position of acetabular components into 28 acetabulums of cadavers (n=12) and dry bone models (n=16). 10 of the dry bone models had complex deformities (crowe 4 hip dysplasia or Paprosky 3A defects).

Surgical positioning. Patient specific “Bullseye” guides were manufactured using 3D printing and standard instruments were used to ream the acetabulum, guided by Bullseye, and position cup components.

Post surgery. The pelvises underwent CT scanning after implantation of acetabular cups. 3D software measured the “radiographic” (as opposed to operative or anatomic) cup inclination and version angles using the anterior pelvic plane as a reference. Achieved position was compared to the plan.

Statistics. We used Bland Altman plots to quantify the strength of the agreement between the planned and achieved cup orientations in terms of fixed bias, correlation coefficient and 2 standard deviation limits of agreement.


Bone & Joint Research
Vol. 6, Issue 1 | Pages 52 - 56
1 Jan 2017
Hothi HS Kendoff D Lausmann C Henckel J Gehrke T Skinner J Hart A

Objectives

Mechanical wear and corrosion at the head-stem junction of total hip arthroplasties (THAs) (trunnionosis) have been implicated in their early revision, most commonly in metal-on-metal (MOM) hips. We can isolate the role of the head-stem junction as the predominant source of metal release by investigating non-MOM hips; this can help to identify clinically significant volumes of material loss and corrosion from these surfaces.

Methods

In this study we examined a series of 94 retrieved metal-on-polyethylene (MOP) hips for evidence of corrosion and material loss at the taper junction using a well published visual grading method and an established roundness-measuring machine protocol. Hips were retrieved from 74 male and 20 female patients with a median age of 57 years (30 to 76) and a median time to revision of 215 months (2 to 324). The reasons for revision were loosening of both the acetabular component and the stem (n = 29), loosening of the acetabular component (n = 58) and infection (n = 7). No adverse tissue reactions were reported by the revision surgeons.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 70 - 70
1 Dec 2016
Alhamzah H Hart A AlSaran Y Burman M Martineau P
Full Access

Our study is still in progress. The results mentioned in the abstract are preliminary results. The final results will be provided at the time of presentation.

Over the past decade, the widespread availability of high-resolution ultrasonography coupled with advances in regional anaesthesia have popularised peripheral nerve blocks for anterior cruciate ligament reconstructions (ACLRs). The aim of this study is to investigate whether the femoral nerve block (FNB) administered at the time of ACLR has any long-term impact on the quadriceps strength as compared to patients who did not receive a FNB.

This is a retrospective study. Four hundred charts of patients who underwent ACLR at our institution and had subsequent Biodex testing (an isokinetic rehabilitation test that provides objective information about muscle strength deficits and imbalances of the operated leg compared to the non-operated leg) from 2004 to 2015 were reviewed. Patients who had prior ipsilateral knee surgery, multi-ligament knee injury or at extreme ages were excluded from the study. The following baseline patient characteristics was recorded for each reviewed chart: age, sex, medical comorbidities, the date of the injury, date of the surgery, surgery technical notes and associated procedures, the surgeon, the hospital were the patient was operated, the Biodex test date and the Biodex test results. Data extraction assessed any association between the ACLR patients' who received FNB with the results of the Biodex test after completing the rehabilitation protocol. Descriptive statistics were used to compare the type of anaesthesia, mode of pain control and the results of the Biodex tests between patients grouped by the mode of anaesthesia used at the time of surgery (FNB versus no FNB). A multivariate regression model then compared quadriceps strength (inferred by Biodex test results) between groups while controlling for baseline differences between groups.

Fifty five percent of the ACLR patients received FNB compared to 45% that did not receive FNB over the last 11 years of performing ACLRs (2004–2015) at our institute. Fifty percent of the patients that received FNB failed to achieve more than or equal to 80% quadriceps strength (compared to the contralateral non-operated leg) at 6 months on Biodex test. On the other hand, only 20% of the non-FNB group failed to achieve more than or equal to 80% quadriceps strength.

This study lead us to think that ACLR patients that received FNB are significantly weaker in quadriceps strength at 6 months post ACLR in comparison to non-FNB ACLR patients. This finding subsequently might affect the time needed to return to sports and might indicate a considerable clinical consequence of the FNB on ACL-reconstruction patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 78 - 78
1 Dec 2016
Hart A Epure L Bergeron S Huk O Zukor D Antoniou J
Full Access

Hip fractures are among the most common orthopaedic injuries and represent a growing burden on healthcare as our population ages. Despite improvements in preoperative optimisation, surgical technique and postoperative care, complication rates remain high. Time to surgery is one of the few variables that may be influenced by the medical team. The aim of the present study was to evaluate the impact of time to surgery on mortality and major complications following surgical fixation of hip fractures.

Utilising the American College of Surgeons' National Quality Improvement Program (NSQIP) database, we analysed all hip fractures (femoral neck, inter-trochanteric, and sub-trochanteric) treated from 2011 to 2013 inclusively. We divided patients into three groups based on time to surgery: less than one day (<24h), one to two days (24–48h), and two to five days (48–120h). Baseline characteristics were compared between groups and a multivariate analysis performed to compare 30-day mortality and major complications (return to surgery, deep wound infection, pneumonia, pulmonary embolus, acute renal failure, cerebrovascular accident, cardiac arrest, myocardial infarction, or coma) between groups.

A total of 14,730 patients underwent surgical fixation of a hip fracture and were included in our analysis. There were 3,475 (24%) treated <24h, 9,960 (67%) treated 24–48h, and 1,295 (9%) treated 48–120h. Thirty-day mortality and major complication rates were 5.0% and 6.2% for the <24h group, 5.3% and 7.0% for the 24–48h group, 7.9% and 9.7% for the 48–120h group respectively. After controlling for baseline demographic differences between groups (age, sex, race) as well as pertinent comorbidities (diabetes, dyspnea, chronic obstructive pulmonary disease, chronic steroid use, hypertension, cancer, bleeding disorders, and renal failure), time to surgery beyond 48h resulted in greater odds of both mortality (1.45, 95%CI 1.10–1.91) and major complications (1.45, 95%CI 1.12–1.84).

Time to surgery is one of the few variables that can be influenced by timely medical assessment and access to the operation room. Expediting surgery within 48h of hip fracture is of paramount importance as it may significantly reduce the risk of mortality as well as major complications.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 45 - 45
1 Oct 2016
Niu J Henckel J Hart A Liu* C
Full Access

Osteoarthritis (OA) affects bone cartilage and underlying bone. Mechanically, the underlying bone provides support to the healthy growth of the overlying cartilage. However, with the progress of OA, bone losses and cysts occur in the bone and these would alter the biomechanical behaviour of the joint, and further leading to bone remodelling adversely affect the overlying cartilage.

Human femoral head and femoral condyle were collected during hip or knee replacement operation due to the end stage of osteoarthritis (age 50–70), and the cartilage patches were graded and marked. A volunteer patient, with minor cartilage injury in his left knee while the right knee is intact, was used as control. Peripheral quantitative computed tomography (pQCT) was used to scan the bone and to determine the volumetric bone mineral density (vBMD) distribution.

The examination of retrieved tissue explants from osteoarthritic patients revealed that patches of cartilage were worn away from the articular surface, and patches of intact cartilage were left. The cysts, ranging from 1 to 10mm were existed in all osteoarthritic bones, and were located close to cartilage defects in the weight-bearing regions, and closely associated with the grade of cartilage defect as measured by pQCT. The bone mineral density (vBMD) distribution demonstrated that the bones around cysts had much higher vBMD than the trabecular bone away from the cysts. Compared to the subchondral bone under thicker cartilage, subchondral bone within cartilage defect has higher vBMD. This may result from the mechanical stimulation as a result of bone-bone direct contact with less protection of cartilage in cartilage defect regions.

This study showed an association between cartilage defect and subchondral bone mineral density distribution. Cysts were observed in all osteoarthritic samples and they are located close to cartilage defects in the weight-bearing regions. Cartilage defect altered the loading pattern of the joints, this leading to the bone remodelling and resultant bone structural changes as compared to the normal bone tissues.

This work was financially supported by The ARUK Proof of Concept Award (grant no: 21160).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 12 - 12
1 Oct 2016
Unadkat R Riehle M Burchmore R Hart A
Full Access

Tissue expansion is a technique used by plastic and restorative surgeons to cause the body to grow additional skin, bone or other tissues. For example, distraction osteogenesis has been widely applied in lower limb surgery (trauma / congenital), and congenital upper limb reconstruction (e.g. radial dysplasia). This complex and tightly regulated expansion process can thus far only be optimised by long-term animal or human experimentation.

Here the intent is to develop an in vitro model of tissue expansion that will allow to both optimise the extension regime (µm/h, continuous/ intermittent) and investigate using proteomic techniques which molecular pathways are involved in its regulation. Cells cultured onto sheets of polymer (PCL) can be stretched at very low, adjustable speeds, using a stepper motor and various 3D printed and laser cut designs. The system utilises plastic flow of the polymer, enabling the material to stay extended upon strain being released.

Tensile tests have displayed the plastic behaviour of the polymer sheet when stretched, and digital image correlation (DIC) has been used to analyse homogeneity of the strain field. Further analysis involving nuclear localisation of yes-associated protein (YAP) aims to link cell response to this strain field.

Nuclear orientation analysis has demonstrated a morphological response to strain (1 mm/day) in comparison to not being stretched, and this is in the process of being linked to nanoscale changes of the substrate (using atomic force microscopy) during the stretching regime. Future work will identify how strain is affecting the cell cycle, before a mass tagging approach is used to identify protein changes induced by strain.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 3 - 3
1 Jun 2016
Laura AD Whittaker R Hothi H Kwon Y Skinner J Hart A
Full Access

Introduction

Dual-mobility bearings increase the stable range of motion of total hip arthroplasty (THA) but are limited by the mechanical effects of a large diameter metal on polyethylene bearing which may cause high rates of wear from the surfaces of the polyethylene bearing and the head-stem taper. Improved polyethylene (PE) has reduced concern over bearing wear but the effects on the taper junction are unknown.

We aimed to better understand the effect of dual mobility bearings on fretting-corrosion damage to the taper junction by comparison to standard bearings.

Materials and Methods

We collected and analysed retrieved hips of one design with either dual mobility (n= 39) or standard bearings (n=30). The bearing size in the dual mobility group was 42mm whereas in the standard bearing group it had a median of 36mm. Stem trunnions had V40 tapers. Time of implantation and body mass index were comparable between the two groups.

Fretting and corrosion at the stem trunnions was quantified by: 1) visual scoring and 2) surface profilometry.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 22 - 22
1 Jun 2016
Davidson J Sabah S Berber R Hothi H Miles J Carrington R Power A Skinner J Hart A
Full Access

Introduction

The Birmingham Hip Resurfacing (Smith & Nephew London, UK) is the most popular hip resurfacing (HR) in the UK. However, it is now subject to two Medical Device Alerts (MDA) from the Medicines and Healthcare products Regulatory Agency (MHRA).

Patients/Materials & Methods

A cross-sectional survey of primary metal-on-metal hip procedures recorded on the National Joint Registry for England, Wales and Northern Ireland (NJR) until 5th November 2013 was performed.

Cost-analysis was based on an algorithm for surveillance of HR at a tertiary referral centre and followed previous MHRA guidance. NIHR NHS Treatment costs were used.

The local protocol encompassed: patient outcome scoring (Oxford hip score), blood metal ion measurement (cobalt, chromium), cross-sectional imaging (MRI) and discussion at an internet-enabled multidisciplinary team meeting (iMDT) in addition to routine hip surveillance.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 25 - 25
1 Jun 2016
Ferguson D Henckel J Holme T Berber R Matthews W Carrington R Miles J Mitchell P Jagiello J Skinner J Hart A
Full Access

Introduction

Surgical simulation and ‘virtual’ surgical tools are becoming recognised as essential aids for speciality training in Trauma & Orthopaedics, as evidenced by the BOA T&O Simulation Curriculum 20131,2. The current generation of hip arthroplasty simulators, including cadaveric workshops, offers the trainee limited exposure to reproducible real life bony pathology. We developed and implemented a novel training course using pathological dry bone models generated from real patient cases to support senior orthopaedic trainees and new consultants in developing knowledge and hands on skills in complex total hip arthroplasty.

Patient/Materials & Methods

A two-day programme for 20 delegates was held at a specialist centre for hip arthroplasty. Three complex femoral and three complex acetabular cases were identified from patients seen at our centre. 3D models were printed from CT scans and dry bone models produced (using a mold-casting process), enabling each delegate to have a copy of each case at a cost of around £30 per case per delegate (Figure 1). The faculty was led by 4 senior Consultant revision hip surgeons. A computerised digitising arm was used to measure cup positioning and femoral stem version giving candidates immediate objective feedback (Figure 2). Candidate experience and satisfaction with the course and models was evaluated with a standardised post-course questionnaire.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 179 - 186
1 Feb 2016
Berber R Skinner J Board T Kendoff D Eskelinen A Kwon Y Padgett DE Hart A

Aims

There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries.

Methods

Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 4 - 4
1 Nov 2015
Osman K Panagiotidou A Meswania J Skinner J Hart A Haddad F Blunn G
Full Access

Introduction

Recent studies on large diameter femoral head hip replacements have implicated the modular taper junction as one of the significant sources of wear and corrosion products and this has been attributed to increased torque and bending on the taper interface. The aim of this study was to assess the effect of frictional torque and bending moment on fretting corrosion at the taper junction and to investigate whether different material combinations also had an effect.

Patients/Materials & Methods

We examined 1) Cobalt Chromium (CoCr) heads on CoCr stems 2) CoCr heads on Titanium alloy (Ti) stems and 3) Ceramic heads on CoCr stems. In test 1 increasing torque was imposed by offsetting the femoral stem in the anterior posterior plane in increments of 0 mm, 4 mm, 6 mm and 8 mm where the force generated was equivalent to 0Nm, 9Nm, 14Nm and 18Nm. In Test 2 we investigated the effect of increasing bending moment by offsetting the application of axial load from the midline in the medial-lateral (ML). Offset increments equivalent to +0, +7 and +14 heads were used. For each test we used n=3 for each different material combination.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 27 - 27
1 Nov 2015
Berber R Khoo M Carrington R Miles J Skinner J Hart A
Full Access

Introduction

Uncertainties in the management of patients with MOM hip implants continue to be a problem for all surgeons. Guidelines vary and do not fully define or quantify thresholds. We aimed to assess the differences in decision-making amongst an international community of six specialist orthopaedic institutions.

Methods

Five international tertiary referral orthopaedic units (one UK, two USA, and two European) were invited to participate. Each unit organised an MDT panel consisting of 2 or more hip surgeons and a musculoskeletal radiologist. All units discussed the same 10 patients. A full clinical dataset was provided including blood test and all imaging. Differences in the interpretation of findings, management decision and rationale for decisions were compared between institutions.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 26 - 26
1 Nov 2015
Skinner J Sabah S Henckel J Cook E Hothi H Hart A
Full Access

Introduction

The National Joint Registry (NJR) for England, Wales and Northern Ireland contributes important information on the performance of implants and surgeons. However, the quality of this data is not known. This study aimed to perform an independent validation of primary metal-on-metal hip procedures recorded on the NJR through linkage to the London Implant Retrieval Centre (LIRC).

Patients/Materials & Methods

Primary, metal-on-metal hip arthroplasties performed between 1st April 2003 and 5th November 2013 were recruited from the NJR (n=67045). Retrieved, metal-on-metal components were recruited from the LIRC (n=782). Data linkage and validation checks were performed.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 2 - 2
1 Nov 2015
Govind G Henckel J Hothi H Sabah S Skinner J Hart A
Full Access

Introduction

Retrieved metal-on-metal acetabular components are invaluable resources from which to investigate the wear behaviour of failed hip implants. New forensic and investigative techniques continue to be developed to help the surgeon further understand factors which contribute to early failure. We have developed a novel technique to locate the in vivo location of the primary wear scar of an explanted cup.

Patients/Materials & Methods

Thirteen (13) patients with failed metal hip resurfacings were recruited and their acetabular components retrieved. A 3D wear map was generated and the precise location of the primary wear scar in each cup was identified using a coordinate measuring machine (CMM). This wear scar position and location was noted in relation to standard landmarks on the acetabular cup. All patients underwent a computerised tomography (CT) scan prior to revision surgery. The 3D positional map from the CMM was then co-registered with the implant on the patient's pelvic 3D CT scan.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 463 - 472
1 Apr 2015
Panagiotidou A Meswania J Osman K Bolland B Latham J Skinner J Haddad FS Hart A Blunn G

The aim of this study was to assess the effect of frictional torque and bending moment on fretting corrosion at the taper interface of a modular femoral component and to investigate whether different combinations of material also had an effect. The combinations we examined were 1) cobalt–chromium (CoCr) heads on CoCr stems 2) CoCr heads on titanium alloy (Ti) stems and 3) ceramic heads on CoCr stems.

In test 1 increasing torque was imposed by offsetting the stem in the anteroposterior plane in increments of 0 mm, 4 mm, 6 mm and 8 mm when the torque generated was equivalent to 0 Nm, 9 Nm, 14 Nm and 18 Nm.

In test 2 we investigated the effect of increasing the bending moment by offsetting the application of axial load from the midline in the mediolateral plane. Increments of offset equivalent to head + 0 mm, head + 7 mm and head + 14 mm were used.

Significantly higher currents and amplitudes were seen with increasing torque for all combinations of material. However, Ti stems showed the highest corrosion currents. Increased bending moments associated with using larger offset heads produced more corrosion: Ti stems generally performed worse than CoCr stems. Using ceramic heads did not prevent corrosion, but reduced it significantly in all loading configurations.

Cite this article: Bone Joint J 2015;97-B:463–72.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 78 - 78
1 Dec 2013
Hothi H Cro S Bills P Blunt L Racasan R Blunn GW Skinner JA Hart A
Full Access

Introduction

Metal-on-metal (MOM) total hip arthroplasty using large diameter femoral heads offer clinical advantages however the failure rates of these hips is unacceptably high. Retrieved hips have a wide range of wear rates of their bearing and taper surfaces and there is no agreement regarding the cause of failure.

Detailed visual inspection is the first step in the forensic examination of failed hip components and may help explain the mechanisms of failure. The aim of this study was to determine if there was a correlation between the results of detailed inspections and the volumetric wear of the bearing and taper surfaces of retrieved hips.

Method

Detailed, non-destructive macroscopic and stereomicroscopic examinations of 89 retrieved MOM hip components were performed by a single experienced examiner using quantitative assessment to document the severity of 10 established damage features:

Light scratches, Moderate scratches, Heavy scratches, Embedded particles, Discolouration, Haziness, Pitting, Visible wear zone, Corrosion, Fretting

Each surface was considered in terms of zones comprising of quadrants (cup, head, and taper) and subquadrants (cup and head), Figure 1. Each zone was scored on a scale of 0 to 3 by determining the percentage of the surface area of the zone that exhibited the feature in question: a score of 0=0%, 1<25%, 25%<2<75%, 3>75%. The sum of the scores of each zone was used for the assessment of each damage feature.

The volume of wear at the surfaces of each hip was measured with a Zeiss Prismo coordinate measuring machine (cup and head) and a Talyrond 365 roundness measurement instrument (taper), using previously reported methods1, 2.

Simple linear regression models were used to asses the univariable associations between the inspection scores and wear volumes. Multiple linear regression models were subsequently used to asses the simultaneous contribution of the inspection scores, found significant in univariable analyses, on the wear outcome variables.

All statistical analysis was performed using Stata/IC version 12.1 (StataCorp, USA) and throughout a p value < 0.05 was considered statistically significant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 474 - 474
1 Dec 2013
Panagiotidou A Meswania J Hua J Muirhead-Allwood SK Skinner JA Hart A Blunn G
Full Access

Introduction:

There has been widespread concern regarding the adverse tissue reactions after metal-on-metal (MoM) total hip replacements (THR). Concerns have also been expressed with mechanical wear from micromotion and fretting corrosion at the head/stem taper junction in total hip replacements. In order to understand the interface mechanism a study was undertaken in order to investigate the effect of surface finish and contact area associated with modular tapers in total hip replacements with a single combination of materials of modular tapers.

Methods:

An inverted hip replacement setup was used (ASTM F1875-98). 28 mm Cobalt Chrome (CoCr) femoral heads were coupled with either full length (standard) or reduced length (mini) 12/14 Titanium (Ti) stem tapers. These Ti stem tapers had either a rough or smooth surface finish whilst all the head tapers had a smooth surface finish. Wear and corrosion of taper surfaces were compared after samples were sinusoidally loaded between 0.1 kN and 3.1 kN for 10 million cycles at 4 Hz. In test 1 rough mini stem tapers were compared with rough standard stem tapers whilst in test 2 rough mini stem tapers were compared with smooth mini stem tapers. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed between rough mini stem tapers and smooth mini stem tapers under loaded and non-loaded conditions.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 142 - 142
1 Dec 2013
Alexander J Hexter A Ismaily S Hart A Noble P
Full Access

Introduction

Tribo-chemical damage of modular taper junctions is often observed at revision THR and may be a contributing factor to chronic inflammation of peri-prosthetic tissues through generation of chromium rich corrosion products. At the time of revision, surgeons may elect to leave the primary femoral stem in situ and replace the original femoral head with a new component. This decision is based on the assumption that the interface formed between the original trunnion and the new bore is capable of withstanding the loads and torques applied during use, without failure of the new interface. This study was performed to determine the extent to which the mechanical properties of the taper interface are degraded with varying degrees of tribo-chemical damage secondary to prior implantation.

Materials and Methods

Fifteen CoCr femoral heads (DePuy: 6, Smith & Nephew: 5; Zimmer: 4) were retrieved at revision THR and were examined with stereomicroscopy. The surface of each bore was scored for the presence of fretting and corrosion using the grading system of Goldberg et al. Nine additional heads in original (unimplanted) condition (3 per manufacturer) were also selected to act as controls. Each head was manually assembled on a matching unimplanted TiAlV trunnion in a mechanical testing machine (MTS Bionix) and loaded at 500N/sec to a maximum assembly load of 4000N. The head/trunnion specimen was then mounted in a torsional loading fixture and immersed in bovine serum. A cyclic torque was applied to the head with an initial maximum value of 2 Nm. The specimen was unloaded and held for a 30 sec wait period and the torsional loading was repeated to a peak value of 4 Nm. With each torsional cycle the peak torque was increased by 2 Nm until the taper junction underwent rotational failure. During testing, relative motion between the femoral head and the trunnion was measured with a displacement transducer (DVRT-3, MicroStrain, accuracy = ± 0.1%, resolution = 1.5 μm, hysteresis & repeatability = ± 1 μm). A separate disassembly test was performed by first assembling each specimen with 4000N and then applying a distraction force at 0.008 mm/sec until separation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 473 - 473
1 Dec 2013
Panagiotidou A Bolland B Meswania J Skinner J Haddad F Hart A Blunn G
Full Access

Introduction:

High failure rates with large diameter, metal on metal hip replacements have highlighted a potential issue with the head/stem taper junction as one of the significant sources of metal ion release. Postulated reasons as to why this may be such a problem with large head metal on metal hip replacements is due to the increased torque achieved by the larger head size. This may be responsible for applying greater micromotion between the head and stem taper and consequently greater amounts of fretting corrosion. The aim of this study was to perform short term in vitro electrochemical tests to assess the effect of increasing head diameter and torque on the fretting corrosion susceptibility of the head/stem taper interface and to investigate its effect on different material combinations.

Methods:

36 mm Cobalt Chrome (CoCr) femoral heads were coupled with either a CoCr or Titanium (Ti) stem with 12/14 tapers, all with a smooth surface finish. Increasing perpendicular horizontal offsets in the sagittal plane created incremental increases in torque. Offset increments of 0 mm, 5.4 mm and 7.5 mm were selected (Figure 1) to simulate the torque force equivalent to 9 Nm, 12 Nm and 17 Nm. An inverted hip replacement setup was used (ASTM F1875-98) (Figure 2). Components were statically loaded at 0 kN and 2.3 kN prior to sinusoidal cyclic loading and electrochemical testing. Mean & fretting currents were calculated every 50 cycles up to a maximum of 1000 cycles of sinusoidal cyclic loading at 3 Hz along with the Overall Mean Current (OMC), Overall Mean Fretting Current (OMFC) and Overall Current change (OCC).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 77 - 77
1 Dec 2013
Hothi H Berber R Whittaker R Cro S Blunn G Skinner JA Hart A
Full Access

Introduction

It has been suggested that corrosion and fretting at the taper junctions of stemmed metal-on-metal hip replacements may contribute to their high failure rates. A peer-reviewed semi-quantitative scoring system [Goldberg et al., 2002] has been used to visually assess the severity of corrosion and fretting of the taper junction but has not been validated using multiple examiners. The aim of this study was to assess the inter-observer variability of this method.

Method

Macroscopic and stereomicroscopic examinations of the femoral head and stem tapers of 100 retrieved large diameter metal on metal (MOM) hip components were performed by two independent observers using the methods defined by Goldberg et al. [2002] to quantify corrosion and fretting. Scores ranging from 1 (none) to 4 (severe) were assigned to the medial, lateral, posterior and anterior quadrants of the neck taper and the distal and proximal regions of the head taper. An overall score was then assigned to each surface as a whole.

Cohen's weighted Kappa statistic (κ) was used to measure the inter-observer agreement. A quadratic weighting scheme, that allocated weights to the importance of disagreements that are proportional to the square of the number of categories apart, was used to take account of scaled disagreement.

Kappa values were assessed using previously established criteria where κ ≤ 0 = poor, 0.01 to 0.20 = slight, 0.21 to 0.40 = fair, 0.41 to 0.60 = moderate, 0.61 to 0.80 = substantial, 0.81 to 1 = almost perfect.

A sample size of 100 was used in order to detect a coefficient of 0.60 to within 0.25 with 95% confidence with two experienced observers. Statistical analysis was performed using Stata/IC version 12.1 (StataCorp, College Station, TC, USA) and a p value < 0.05 was considered statistically significant.