header advert
Results 1 - 76 of 76
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 14 - 14
2 May 2024
Menakaya C Durand-Hill M Carrington R Hart A Donaldson J Miles J Briggs T Skinner J
Full Access

The management of femoral bone loss is challenging during revision hip arthroplasty. In patients with Paprosky grade IIIB and IV defects, obtaining fixation and rotational stability using traditional surgical constructs is difficult. The use of a custom-made internal proximal femoral replacement prostheses has been proposed as a solution in patients, with severe femoral bone stock loss. However, there is a paucity in the literature on their use and long-term outcomes. We report on the clinical and radiological results of our cohort.

We retrospectively reviewed all patients who underwent internal proximal femoral replacement for revision hip arthroplasty between April 1996 and April 2019. All patients had at least 2 years of follow-up time.

160 patients underwent limb salvage at our institution using internal proximal femoral replacement. The mean follow-up was 79.7 months (S.D 41.3). Indications for revision included periprosthetic fractures, aseptic loosening, and deep infection. The mean Oxford hip score increased from 13.8 (0–22) to 31.5 (18–43) (paired t-test, p < 0.001). Kaplan-Meier prosthesis survival analysis with revision as the endpoint was 87% at 5 years. None required revision of the femoral stem. There were four dislocations (5%) and there was failure to eradicate the deep infection in four.

This technique allows instant distal fixation, allowing for early mobilisation. Long-term clinical and radiological outcomes are encouraging and the complication rates are acceptable for this patient group.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 41 - 41
7 Aug 2023
Al-Jabri T Bentley G McCulloch R Miles J Carrington R Shearman A Donaldson J Jayadev C
Full Access

Abstract

Background

Autologous chondrocyte implantation is a NICE approved intervention however it involves the morbidity of two operations, a prolonged rehabilitation and substantial healthcare costs. This study describes a novel, one-step, bone marrow (BM) derived mesenchymal stem cell (MSC) transplantation technique for treating knee osteochondral lesions and presents our prospective clinical study investigating the success of this technique in 206 lesions over a 5 year period.

Methodology

The surgical technique involves harvesting BM from patients’ anterior superior iliac spines, centrifugation to isolate MSCs and seeding into a type 1 collagen scaffold (SyngenitTM Biomatrix). Autologous fibrin glue is used to secure the scaffold into the defect. Inclusion criteria included patients aged 15 – 55 years old with symptomatic osteochondral lesions >1cm2. Exclusion criteria included patients with ligament instability, uncorrected alignment, inflammatory arthropathy and a Body Mass Index >35 kg/m2. Outcome measures included the Modified Cincinnati Knee Rating System (MCKRS), complications and reoperations.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 37 - 37
7 Aug 2023
Mudiganty S Jayadev C Carrington R Miles J Donaldson J Mcculloch R
Full Access

Abstract

Introduction

Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR.

Methodology

We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 17 - 17
7 Jun 2023
Madanipour S Lemanu D Jayadev C Aston W Donaldson J Miles J Carrington R McCulloch R Skinner J
Full Access

Custom acetabular components have become an established method of treating massive acetabular bone defects in hip arthroplasty. Complication rates, however, remain high and migration of the cup is still reported. Ischial screw fixation (IF) has been demonstrated to improve mechanical stability for non-custom, revision arthroplasty cup fixation. We hypothesise that ischial fixation through the flange of a custom acetabular component aids in anti-rotational stability and prevention of cup migration.

Electronic patient records were used to identify a consecutive series of 49 custom implants in 46 patients from 2016 to 2022 in a unit specializing in complex joint reconstruction. IF was defined as a minimum of one screw inserted into the ischium passing through a hole in a flange on the custom cup.

The mean follow-up time was 30 months. IF was used in 36 cups. There was no IF in 13 cups. No difference was found between groups in age (68.9 vs. 66.3, P = 0.48), BMI (32.3 vs. 28.2, P = 0.11) or number of consecutively implanted cups (3.2 vs. 3.6, P = 0.43). Aseptic loosening with massive bone loss was the primary indication for revision. There existed no difference in Paprosky grade between the groups (P = 0.1). 14.2% of hips underwent revision and 22.4% had at least one dislocation event.

No ischial fixation was associated with a higher risk of cup migration (6/13 vs. 2/36, X2 = 11.5, P = 0.0007). Cup migration was associated with an increased risk for all cause revision (4/8 vs. 3/38, X2 = 9.96, P = 0.0016, but not with dislocation (3/8 vs. 8/41, X2 = 1.2, P = 0.26).

The results suggest that failure to achieve adequate ischial fixation, with screws passing through the flange of the custom component into the ischium, increases the risk of cup migration, which, in turn, is a risk factor for revision.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 37 - 37
1 Jul 2022
McCulloch R Palmer A Donaldson J Kendrick B Warren S Atkins B Alvand A Carrington R Taylor A Miles J
Full Access

Abstract

Aims

The primary aim of this study was to evaluate the outcomes of fungal knee periprosthetic joint infection following knee arthroplasty. The secondary aim was to evaluate risk factors for acquiring a fungal PJI.

Patients and Methods

This was a retrospective analysis of patients presenting with a confirmed fungal PJI of the knee in two tertiary centres. There were a total of 45 cases. Isolated fungal infections along with mixed bacterial and fungal infections were included. Mean follow up was 40 months (range 3–118).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 80 - 80
1 Apr 2018
Sugand K van Duren B Wescott R Carrington R Hart A
Full Access

Background

Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure.

Methods

This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR) were recorded for each attempt.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 81 - 81
1 Apr 2018
Sugand K Wescott R van Duren B Carrington R Hart A
Full Access

Background

Training within surgery is changing from the traditional Halstedian apprenticeship model. There is need for objective assessment of trainees, especially their technical skills, to ensure they are safe to practice and to highlight areas for development. In addition, due to working time restrictions in both the UK and the US, theatre time is being limited for trainees, reducing their opportunities to learn such technical skills. Simulation is one adjunct to training that can be utilised to both assess trainees objectively, and provide a platform for trainees to develop their skills in a safe and controlled environment. The insertion of a dynamic hip screw (DHS) relies on complex psychomotor skills to obtain an optimal implant position. The tip-apex distance (TAD) is a measurement of this positioning, used to predict failure of the implant. These skills can be obtained away from theatre using workshop bone simulation, however this method does not utilise fluoroscopy due to the associated radiation risks. FluoroSim is a novel digital fluoroscopy simulator that can recreate digital radiographs with workshop bone simulation for the insertion of a DHS guide-wire. In this study, we present the training effect demonstrated on FluoroSim. The null hypothesis states that no difference will be present between users with different amounts of exposure to FluoroSim.

Methods

Medical students were recruited from three London universities and randomised into a training (n=23) and a control (n=22) cohort. All participants watched a video explanation of the simulator and task and were blinded to their allocation. Training participants completed 10 attempts in total, 5 attempts in week one, followed by a one week wash out period, followed by 5 attempts in week 2. The control group completed a single attempt each week. For each attempt, 5 metrics were recorded; TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 79 - 79
1 Apr 2018
van Duren B Wescott R Sugand K Carrington R Hart A
Full Access

Background

Hip fractures affect 1.6 million people globally per annum, associated with significant morbidity and mortality. A large proportion are extracapsular neck of femur fractures, treated with the dynamic hip screw (DHS). Mechanical failure due to cut-out is seen in up to 7% of DHS implants. The most important predictor of cut-out is the tip-apex distance (TAD), a numerical value of the lag screw”s position in the femoral head. This distance is determined by the psychomotor skills of the surgeon guided by fluoroscopic imaging in theatre. With the current state of surgical training, it is harder for junior trainees to gain exposure to these operations, resulting in reduced practice. Additionally, methods of simulation using workshop bones do not utilise the imaging component due to the associated radiation risks. We present a digital fluoroscopy software, FluoroSim, a realistic, affordable, and accessible fluoroscopic simulation tool that can be used with workshop bones to simulate the first step of the DHS procedure. Additionally, we present the first round of accuracy tests with this software.

Methods

The software was developed at the Royal National Orthopaedic Hospital, London, England. Two orthogonally placed cameras were used to track two coloured markers attached to a DHS guide-wire. Affine transformation matrices were used in both the anterior-posterior (AP) and cross table lateral (CTL) planes to match three points from the camera image of the workshop bone to three points on a pre-loaded hip radiograph. The two centre points of each marker were identified with image processing algorithms and utilised to digitally produce a line representing the guide-wire on the two radiographs. To test the accuracy of the system, the software generated 3D guide-wire apex distance (GAD) (from the tip of the guide-wire to a marker at the centre of calibration) was compared to the same distance measured with a digital calliper (MGAD). In addition, the same accuracy value was determined in a simulation scenario, from 406 attempts by 67 medical students.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 19 - 19
1 Jun 2016
Stirling E Gikas P Aston W Miles J Pollock R Carrington R Skinner J Briggs T
Full Access

Introduction

THR is one of the most frequently performed operations nationally. A large number of prostheses are available, and the procedure is therefore associated with variation in practice and outcomes. NICE guidelines aim to standardise best practice, and are informed by separate, independent bodies, such as the NJR and ODEP, which monitor data about the implants used and their performance. This study aims to determine whether clinical practice and component use has changed since the publication of NJR data.

Methods

NJR reports from 2006–2014 were analysed, with record made of the different prostheses used in THR, noting ODEP ratings of components used. Analysis was also performed by component type (i.e. cemented and cementless stems and cups), and combinations of components, according to their frequency of use in a given year. The Kruksal-Wallis test was used for statistical analysis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 22 - 22
1 Jun 2016
Davidson J Sabah S Berber R Hothi H Miles J Carrington R Power A Skinner J Hart A
Full Access

Introduction

The Birmingham Hip Resurfacing (Smith & Nephew London, UK) is the most popular hip resurfacing (HR) in the UK. However, it is now subject to two Medical Device Alerts (MDA) from the Medicines and Healthcare products Regulatory Agency (MHRA).

Patients/Materials & Methods

A cross-sectional survey of primary metal-on-metal hip procedures recorded on the National Joint Registry for England, Wales and Northern Ireland (NJR) until 5th November 2013 was performed.

Cost-analysis was based on an algorithm for surveillance of HR at a tertiary referral centre and followed previous MHRA guidance. NIHR NHS Treatment costs were used.

The local protocol encompassed: patient outcome scoring (Oxford hip score), blood metal ion measurement (cobalt, chromium), cross-sectional imaging (MRI) and discussion at an internet-enabled multidisciplinary team meeting (iMDT) in addition to routine hip surveillance.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 25 - 25
1 Jun 2016
Ferguson D Henckel J Holme T Berber R Matthews W Carrington R Miles J Mitchell P Jagiello J Skinner J Hart A
Full Access

Introduction

Surgical simulation and ‘virtual’ surgical tools are becoming recognised as essential aids for speciality training in Trauma & Orthopaedics, as evidenced by the BOA T&O Simulation Curriculum 20131,2. The current generation of hip arthroplasty simulators, including cadaveric workshops, offers the trainee limited exposure to reproducible real life bony pathology. We developed and implemented a novel training course using pathological dry bone models generated from real patient cases to support senior orthopaedic trainees and new consultants in developing knowledge and hands on skills in complex total hip arthroplasty.

Patient/Materials & Methods

A two-day programme for 20 delegates was held at a specialist centre for hip arthroplasty. Three complex femoral and three complex acetabular cases were identified from patients seen at our centre. 3D models were printed from CT scans and dry bone models produced (using a mold-casting process), enabling each delegate to have a copy of each case at a cost of around £30 per case per delegate (Figure 1). The faculty was led by 4 senior Consultant revision hip surgeons. A computerised digitising arm was used to measure cup positioning and femoral stem version giving candidates immediate objective feedback (Figure 2). Candidate experience and satisfaction with the course and models was evaluated with a standardised post-course questionnaire.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 27 - 27
1 Nov 2015
Berber R Khoo M Carrington R Miles J Skinner J Hart A
Full Access

Introduction

Uncertainties in the management of patients with MOM hip implants continue to be a problem for all surgeons. Guidelines vary and do not fully define or quantify thresholds. We aimed to assess the differences in decision-making amongst an international community of six specialist orthopaedic institutions.

Methods

Five international tertiary referral orthopaedic units (one UK, two USA, and two European) were invited to participate. Each unit organised an MDT panel consisting of 2 or more hip surgeons and a musculoskeletal radiologist. All units discussed the same 10 patients. A full clinical dataset was provided including blood test and all imaging. Differences in the interpretation of findings, management decision and rationale for decisions were compared between institutions.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 21 - 21
1 Mar 2013
RAHMAN J KAYANI B GILLOTT E BENTLEY G SKINNER J MILES J CARRINGTON R BRIGGS T
Full Access

The Royal National Orthopaedic Hospital has completed an extensive trial of ACI versus MACI in the treatment of symptomatic osteochondral defects of the knee. A new technique has now been proposed which is quicker and easier to perform. This is the Gel-Type Autologous Chondrocyte Transplantation, CHONDRONTM. At Stanmore CHONDRON has been used for the past 17 months. Our aim was to assess the short term functional outcome of patients who have undergone CHONDRONTM using validated outcome scoring questionnaires. We retrospectively reviewed the notes of 43 patients that had undergone CHONDRONTM over one year ago and scored them using the Modified Cincinnati Score, the Visual Analogue Score and the Benltey Stanmore Functional Rating Score.

RESULTS

The mean pre-operative Modified Cincinnati Score was 39.9, which improved to a mean of 59.8 post-operatively. The mean Visual Analogue Score improved from 6.7 to 5.1 post-operatively. The median Bentley Functional Rating Score was 3 pre-operatively and 2 post-operatively.

CONCLUSIONS

These early results show that 76% of the patients who were treated with CHONDRONTM experienced a reduction in pain and improvement in post-operative function. In the patients in whom the symptoms were worse, the deterioration in score could be partly explained by numerous previous procedures on the same site, presence of early osteoarthritis or the presence of multiple osteochondral lesions. This highlights the importance of careful patient selection in order to gain maximum benefit from the procedure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 7 - 7
1 Feb 2013
Sewell M Carrington R Pollock R Skinner J Cannon S Briggs T
Full Access

Patients with skeletal dysplasia are prone to developing advanced degenerative knee disease requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure due to the bone deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We set out to retrospectively review the outcome of 11 TKR's performed in eight patients with skeletal dysplasia at our institution using the SMILES custom-made rotating-hinge total knee system. There were 3 males and 5 females with mean age 57 years (range, 41–79 years), mean height 138 cm (range, 122–155 cm) and mean weight 56 kg (range, 40–102 kg). Preoperative diagnoses included achondroplasia, spondyloepiphyseal dysplasia, pseudoachondroplasia, multiple epiphyseal dysplasia, morquio syndrome, diastrophic dysplasia and Larson's Syndrome. Patients were followed clinically and radiographically for a mean of 7 years (range, 3–11.5 years). Knee pain and function improved in all 11 joints. Mean Knee Society clinical and function scores improved from 24 (range, 14–36) and 20 points (range, 5–40) preoperatively to 68 (range, 28–80) and 50 points (range, 22–74) respectively at final follow-up. Four complications were recorded (36%), including a patellar fracture following a fall, a tibial periprosthetic fracture, persistent anterior knee pain and a femoral component revision for aseptic loosening. Our results suggest that custom rotating-hinge TKR in patients with skeletal dysplasia is effective at relieving pain, optimising movement and improving function. It compensates for bony deformity and ligament deficiency and reduces the need for corrective osteotomy. Patellofemoral joint complications are frequent and functional outcome is worse than primary TKR in the general population.

Submission endorsed by Mr Peter Calder, Consultant Orthopaedic Surgeon and Society member


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 31 - 31
1 Jan 2013
Dhinsa B Gallagher K Dawson-Bowling S Mohan A Miles J Carrington R Skinner J Briggs T
Full Access

Introduction

The aim of this study was to see if the evaluation of the initial postoperative radiograph following primary knee and hip arthroplasty correlated with clinical outcome at five years postoperatively.

Methodology

Using our institution database we identified forty-nine hip replacements and fifty-two knee replacements performed between 2000 and 2006. All the patients underwent postoperative radiographs one day after surgery and clinical evaluation up to at least five years postoperatively. A consultant radiologist evaluated the radiographs for alignment and component position. The hip arthroplasty patients were assessed clinically using the Harris hip score, Oxford hip score, and the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC). The knee arthroplasty patients were assessed using the Knee Society score, Oxford knee score, and the WOMAC score.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 73 - 73
1 Jan 2013
Gillott E Sun SNM Carrington R Skinner J Briggs T Miles J
Full Access

Background

The Enhanced Recovery Programme (ERP) is an evidence based initiative aimed at speeding up patient recovery after major surgery and improving their outcomes. The Royal National Orthopaedic Hospital, Stanmore (RNOH) is a specialist orthopaedic and implemented an ERP for primary knee arthroplasties from October 2010.

Aims

To analyse the initial results of patients participating in our ERP for primary knee arthroplasty to identify what factors predict their Length of Stay (LoS) and establish where changes can be made to improve outcomes further.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 85 - 85
1 Sep 2012
Stammers J Kahane S Malek S Aston W Miles J Pollock R Carrington R Briggs T Skinner J
Full Access

Infection after knee arthroplasty is a devastating complication. Our aim is to present our outcomes of treating infected knee replacements at a tertiary referral centre.

We performed a consecutive, retrospective case series of all revision knee arthroplasty for infection between January 2006 and December 2008. Case notes were reviewed and data collated on the date and institution of primary arthroplasty, procedures undertaken at our institution, microbiology and bone loss post first stage, serological markers (C-reactive protein, ESR) prior to second stage and outcome.

During this three year period we performed 430 knee revision operations. 51 were in the presence of deep chronic infection. 90% were referred from other hospitals. Overall infection was successfully eradicated in 69%.

Nineteen patients underwent repeat two-stage and overall eleven (58%) patients had successful eradication of infection with multiple two-stages. Of these 47% had F3/T3, the highest grading of Anderson Orthopaedic Research Institute bone loss indicating no metaphyseal bone. A further 12% had bicondylar deficiency on the tibia and no femoral metaphyseal bone (F3/T2b).

Multidrug resistance present in 69% and 47% were infected with multiple organisms. All members of the unsuccessful outcome group had at least one multidrug resistant organism compared to 43% in the successful cohort (P=0.0002). Multiple organisms are associated with an unsuccessful outcome (P=0.056).

Serological markers were not significantly different between the successful and unsuccessful outcome groups.

Where the referring hospital had attempted revision and failed, the chance of eradicating infection dropped from 75% to 58% and the rate of above knee amputation was twelve times higher (3% vs. 36%).

Custom constrained, rotating hinge prostheses enable aggressive soft tissue debridement including ligaments. Successful two-stage requires a multidisciplinary approach including tissue viability nurses, microbiologists and plastic surgeons. Where units lack revision expertise this series suggests early referral increases the chance of limb salvage.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 90 - 90
1 Sep 2012
Nawaz S Gallagher K Dhinsa B Carrington R Skinner J Briggs T Bentley G
Full Access

Chondral injuries of the knee are extremely common and present a unique therapeutic challenge due to the poor intrinsic healing of articular cartilage. These injuries can lead to significant functional impairment. There are several treatment modalities for articular osteochondral defects, one of which is autologous chondrocyte implantation. Our study evaluates the mid to long term functional outcomes in a cohort of 828 patients who have undergone an autologous chondrocyte implantation procedure (either ACI or MACI), identifying retrospectively factors that may influence their outcome.

The influence of factors including age, sex, presence of osteoarthritis and size and site of lesion have been assessed individually and with multivariate analysis. All patients were assessed using the Bentley Functional Score, Visual Analogue Score and the Cincinnati Functional Score. Assessment were performed pre-operatively and of their status in 2010.

The longest follow-up was 12 years (range 24 to 153 months) with a mean age of 34 years at time of procedure. The mean defect size was 409 mm2 (range 64 to 2075 mm2). The distribution of lesions was 51% Medial Femoral Condyle, 12.5% Lateral Femoral Condyle, 18% Patella (single facet), 5% Patella (Multifacet) and 6% Trochlea. 4% had cartilage transplant to multiple sites.

High failure rates were noted in those with previous cartilage regenerative procedures or evidence of early osteoarthritis and those with transplantation to multiple sites.

Autologous chondrocyte implantation is an effective method of decreasing pain and increasing function, however patient selection plays clear role in the success of such procedure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 15 - 15
1 Sep 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

Background

It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome.

Methods

A retrospective study of patients undergoing primary THR at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires after a minimum follow-up of 11 months. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. A factorial linear regression model was used to analyse data.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 571 - 571
1 Sep 2012
Nawaz S Bentley G Briggs T Carrington R Skinner J Gallager K Dhinsa B
Full Access

Chondral injuries of the knee are extremely common and present a unique therapeutic challenge due to the poor intrinsic healing of articular cartilage. These injuries can lead to significant functional impairment. There are several treatment modalities for articular osteochondral defects, one of which is autologous chondrocyte implantation. Our study evaluates the mid to long term functional outcomes in a cohort of 828 patients who have undergone an autologous chondrocyte implantation procedure (either ACI or MACI), identifying retrospectively factors that may influence their outcome.

The influence of factors including age, sex, presence of osteoarthritis and size and site of lesion have been assessed individually and with multivariate analysis. All patients were assessed using the Bentley Functional Score, Visual Analogue Score and the Cincinnati Functional Score. Assessment were performed pre-operatively and of their status in 2010. The majority of patients had several interim scores performed at varying intervals.

The longest follow-up was 12 years (range 24 to 153 months) with a mean age of 34 years at time of procedure. The mean defect size was 486 mm2 (range 64 to 2075 mm2). The distribution of lesions was 51% Medial Femoral Condyle, 12.5% Lateral Femoral Condyle, 18% Patella (single facet), 5% Patella (Multifacet) and 6% Trochlea. 4% had cartilage transplant to multiple sites. 30% failed following this procedure at a mean time of 72 months. 52% patients stated a marked improvement in their functional outcomes within the first two years. 49% stated an excellent result following their procedure.

High failure rate was noted in those with previous cartilage regenerative procedures, transplants occurring on the patella, particularly if involving multifacets. Multiple site cartilage transplantation was also associated with a high failure rate.

Autologous chondrocyte implantation is an effective method of decreasing pain and increasing function, however patient selection plays clear role in the success of such procedure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 231 - 231
1 Sep 2012
Matthews D Bhamra J Gupta A Ranawat V Miles J Skinner J Carrington R
Full Access

Aims

Revision total hip arthroplasty is a common operation. The MP Link (Waldemar Link, Hamburg, Germany) system is a distally loading, modular, tapered femoral stem component for revision hip surgery. MP Link in revision total hip arthoplasty was investigated clinically, radiologically and with Oxford hip scores.

Methods

A prospective study was conducted of 43 patients undergoing revision total hip arthroplasty with MP Link prostheses between 2004 and 2010. The patients were operated upon by one of the senior authors (JM, JS, RC). Outcome data was collected in clinic and via patient questionnaires.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 69 - 69
1 Aug 2012
Picardo N Nawaz Z Gallagher K Whittingham-Jones P Parratt T Briggs T Carrington R Skinner J Bentley G
Full Access

The aim of this study was to determine whether the clinical outcome of autologous chondrocyte transplantation was dependent on the timing of a high tibial osteotomy in tibio-femoral mal-aligned knees. Between 2000 and 2005, forty-eight patients underwent autologous chondrocyte implantation with HTO performed at varying times relative to the second stage autologous chondrocyte implantation procedure. 24 patients had HTO performed simultaneously with their second stage cartilage transplantation, (the HTO Simultaneous Group). 5 patients had HTO prior to their cartilage procedure, (the HTO pre-ACI Group) and 19 had HTO performed between 1 to 4 years after their second stage cartilage implantation, (the HTO post-ACI Group). There were 29 men and 19 women with a mean age of 37 years (Range 28 to 50) at the time of their second stage procedure.

With average follow-up of 72 months we have demonstrated a significant functional benefit in performing the HTO either prior to or simultaneously with the ACI procedure in the mal-aligned knee. The failure rate in the Post-ACI group was 45% compared to the Pre-ACI and Simultaneous group, with failure rates of 20% and 25%, respectively.

An HTO performed prior to or simultaneously with an autologous chondrocyte implantation procedure in the mal-aligned knee, provides a significant protective effect by reducing the failure rate by approximately 50%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 5 - 5
1 Aug 2012
Dhinsa B Perera J Gallagher K Spiegelberg B Hanna S Tai S Pollock R Carrington R Cannon S Briggs T
Full Access

The aim of this study is to investigate whether MoM implants result in more chromosome aberrations and increased blood metal ions postoperatively whe compared to MoP implants.

MoM arthroplasties are being inserted in increasing numbers of younger patients due to the increased durability and reduced requirements for revision in these implants. Recent studies have raised many concerns over possible genotoxicity of MoM implants.

This is a prospective study of patients who have undergone elective total hip replacement, they were selected and then randomised into two groups. Group A received a MoP implant and group B received a MoM implant. Patients are reviewed pre-operatively (control group), at 3 months, 6 months, 1 year and 2 years post-operatively. On each occasion blood tests are taken to quantify metal ion levels (chromium, cobalt, titanium, nickel and vanadium) using HR-ICPMS method and chromosome aberrations in T lymphocytes using 24 colour fluorescent in situ hydridisation (FISH).

51 patients have been recruited to date, 23 of whom had MoP prosthesis and 28 a MoM. 47 of these had their 1 year follow-up with blood analysis and 38 have had 2 year follow up. There appeared to be a bedding period for both MoM and MoP groups, with an increase in metal ion release. The blood concentration of chromium, cobalt and titanium rise significantly in the MoM group at the 2 year stage. Chromosome aberrations occurred in both groups. Both the MoM and MoP groups showed increase frequency of aneuploidy aberrations and structural damage. The greatest increase in metal ion levels occurred at the 1 to 2 year interval corresponding to significant rise in chromosome aberrations.

Preliminary results of this study show that the levels of chromium, cobalt and titanium are significantly higher in the MoM group compared to the MoP group. This corresponds to increases in chromosome aberrations in the groups with increases in structural chromosome damage after two years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 120 - 120
1 Aug 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

Background

The position of the hip-joint centre of rotation (HJC) within the pelvis is known to influence functional outcome of total hip replacement (THR). Superior, lateral and posterior relocations of the HJC from anatomical position have been shown to be associated with greater joint reaction forces and a higher incidence of aseptic loosening. In biomechanical models, the maximum force, moment-generating capacity and the range of motion of the major hip muscle groups have been shown to be sensitive to HJC displacement. This clinical study investigated the effect of HJC displacement and acetabular cup inclination angle on functional performance in patients undergoing primary THR.

Methods

Retrospective study of primary THR patients at the RNOH. HJC displacement from anatomical position in horizontal and vertical planes was measured relative to radiological landmarks using post-operative, calibrated, anterior-posterior pelvic radiographs. Acetabular cup inclination angle was measured relative to the inter-teardrop line. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 40 - 40
1 Aug 2012
Dhinsa B Nawaz S Gallagher K Carrington R Briggs T Skinner J Bentley G
Full Access

Introduction

Autologous chondrocyte implantation (ACI) is contra-indicated in a joint rendered unstable by a ruptured anterior cruciate ligament (ACL). We present our experience of ACI repair with ACL reconstruction

Methods

Patients underwent arthroscopic examination and cartilage harvesting of the knee. A second operation was undertaken approximately six weeks later to repair the ruptured ACL with hamstring graft or Bone patella-Bone (BPB) and to implant the chondrocytes via formal arthrotomy. Three groups were assessed: Group 1: Simultaneous ACL Reconstruction and ACI; Group 2: Previous ACL Reconstruction with subsequent ACI repair; Group 3: Previously proven partial or complete ACL rupture, deemed stable and not treated with reconstruction with ACI procedure subsequently. Patients then underwent a graduated rehabilitation program and were reviewed using three functional measurements: Bentley functional scale, the modified Cincinnati rating system, and pain measured on a visual analogue scale. All patients also underwent formal clinical examination at review.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 111 - 111
1 Aug 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome.

Methods

Retrospective study of primary THR patients at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.

Results

90 THRs were studied in 87 patients (55 Female). Mean age at THR=62 (22-86). Mean follow-up=17 months (11-39 months). Median OHS=16, WOMAC=8. Coronal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05). Sagittal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 12 - 12
1 Aug 2012
Shekkeris A Perera J Bentley G Flanagan A Miles J Carrington R Skinner J Briggs T
Full Access

Articular cartilage implantation (ACI) and associated procedures (MACI = Matrix-assisted cartilage implantation) are now established treatments for osteochondral defects in the knee. The quality of repair in terms of histological appearance is frequently not known, whilst the correlation of histology results with functional outcomes remains undefined. Histological data of the quality of the repair tissue is sparse and a precise classification proved difficult.

This was a single-centre, prospective study. Over 12 years (1998-2010) 406 patients that underwent articular cartilage implantation procedures at our institution (ACI = 170, MACI = 205) had biopsies taken at the 1-2 year interval, in order to assess whether these contained ‘hyaline-like’ cartilage, ‘mixed hyaline-like with fibrocartilage’, fibrocartilage or fibrous tissue alone.

Histological sections of the biopsies were prepared and stained with haematoxylin, eosin and proteoglycan stains and viewed under polarised light. All biopsies were studied by a single histopathologist in a specialist, dedicated musculoskeletal laboratory.

All patients were assessed by the Cincinnati, Bentley and Visual Analogue scores both pre-operatively and at the time of the review.

The findings revealed that 56 patients healed with ‘hyaline-like’ cartilage (14.9%), 103 with ‘mixed’ (27.5%), 179 with fibrocartilage (47.7%) and 37 with fibrous tissue (9.9%).

These findings showed that 42.4% of defects were filled with ‘hyaline-like’ or ‘mixed’ cartilage, with 70% of these achieving a ‘fair’ to ‘excellent’ functional outcome. This was also observed in the fibrocartilage group, where 72% achieved similar results. Predictably 89% of the patients that healed by fibrous tissue had a poor functional outcome.

This study shows that 71% of patients whose osteochondral defects healed by either ‘hyaline-like’, ‘mixed’ or fibrocartilage experienced an improvement in the function. In contrast, only 11% of the patients whose defects filled with fibrous tissue, showed some functional improvement. Additionally, this data indicates the advantage of biopsies in assessing the overall results of cartilage implantation procedures.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 43 - 43
1 Jun 2012
Dhinsa B Jalgaonkar A Nawaz Z Briggs T Muirhead-Allwood S Carrington R Skinner J Bentley G Miles J
Full Access

Patients with osteochondrodysplasia frequently require Total Hip Arthroplasty at a younger age, as a result of early degenerative disease of the hip joint. The outcome of Modular Total Hip Arthroplasty in this group of patients has been reported previously. In this retrospective study we evaluated the outcome of custom made (CADCAM) Total Hip Arthroplasty in patients with osteochondrodysplasia.

Between 1974 and 2009, twenty one CADCAM Total Hip Arthroplasty procedures were performed in fourteen patients in our institution. There were eight female and six male patients, with the mean age at time of surgery of 40.95 years (20 to 78). The patients were followed up clinically and with the Harris hip score for a mean of 7.12 years (0.5 to 17 years).

Four of the twenty-one hips (23.8%) required revision surgery at a mean of 11.54 years (6.5 to 17 years); one required it for aseptic loosening of the femoral component; one required complete revision of the acetabular component; one required exchange of acetabular liner; and one was for symptomatic non-union of a lesser trochanter avulsion.

This study shows encouraging clinical outcomes of custom made (CADCAM) Total Hip Arthroplasty in patients with osteochondrodysplasia,


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 44 - 44
1 Jun 2012
Dhinsa B Nawaz Z Gallagher K Carrington R Skinner J Briggs T Bentley G
Full Access

Purpose

The rate of arthroplasty or osteotomy in patients who had undergone autologous chondrocyte implantation (ACI) for osteochondral defects in the knee was determined. Furthermore, we investigated whether any radiographic evidence of osteoarthritis (OA) prior to ACI was associated with poorer outcome following surgery.

Methods

We retrospectively reviewed the medical notes and radiographs of 236 patients (mean age 34.9) who underwent ACI from 1998 to 2005 at our institution. Knee function was assessed according to the Modified Cincinnati Score (MCS) pre-operatively and at a mean of 64.3 months postoperatively (range 12 – 130). Radiographic changes were graded according to the Stanmore grading system.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 45 - 45
1 Jun 2012
Dhinsa B Gallagher K Nawaz Z Spiegelberg B Hanna S Tai S Pollock R Carrington R Cannon S Briggs T
Full Access

The aim of this study is to investigate whether Metal-on-Metal (MoM) implants result in more chromosome aberrations and increased blood metal ions post-operatively when compared to Metal-on-Polyethylene (MoP) implants. Metal-on-metal arthroplasties are being inserted in increasing numbers of younger patients due to the increased durability and reduced requirement for revision in these implants. Recent studies have raised many concerns over possible genotoxicity of MoM implants. This is a prospective study of patients who have undergone elective total hip replacement, they were selected and then randomised into two groups. Group A received a MoP implant and group B received a MoM implant. Patients are reviewed pre-operatively (control group), at 3 months, 6 months, 1 year and 2 years post-operatively. On each occasion blood tests are taken to quantify metal ion levels (chromium, cobalt, titanium, nickel and vanadium) using HR-ICPMS method and chromosome aberrations in T lymphocytes using 24 colour fluorescent in situ hybridisation (FISH). 53 patients have been recruited to date. 24 of whom had MoP prosthesis and 29 a MoM. 37 of these have had their one year follow-up with blood analysis and 14 have had 2 year follow up. Cobalt and chromium concentration increased during the first 6 months in both MoM and MoP groups, in the MoM group the chromium levels were twice that of MoP group and 12x that of the preoperative samples. Chromosome aberrations occurred in both groups. At 6 months both the MoM and MoP groups showed increase frequency of aneuploidy aberrations with further increases after one year. Structural damage in the form of translocations occurred in the MoM group after one year, but not in the MoP group, by two years there was a profound increase in translocations Preliminary results of this study show that the levels of chromium and cobalt are significantly higher in the MoM group compared to the MoP group. This corresponds to increases in chromosome aberrations in the groups with increases in structural chromosome damage after two years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 131 - 131
1 Jun 2012
Macmull S Bartlett W Miles J Blunn G Pollock R Carrington R Skinner J Cannon S Briggs T
Full Access

Polymethyl methacrylate spacers are commonly used during staged revision knee arthroplasty for infection. In cases with extensive bone loss and ligament instability, such spacers may not preserve limb length, joint stability and motion.

We report a retrospective case series of 19 consecutive patients using a custom-made cobalt chrome hinged spacer with antibiotic-loaded cement. The “SMILES spacer” was used at first-stage revision knee arthroplasty for chronic infection associated with a significant bone loss due to failed revision total knee replacement in 11 patients (58%), tumour endoprosthesis in four patients (21%), primary knee replacement in two patients (11%) and infected metalwork following fracture or osteotomy in a further two patients (11%). Mean follow-up was 38 months (range 24–70). In 12 (63%) patients, infection was eradicated, three patients (16%) had persistent infection and four (21%) developed further infection after initially successful second-stage surgery. Above knee amputation for persistent infection was performed in two patients.

In this particularly difficult to treat population, the SMILES spacer two-stage technique has demonstrated encouraging results and presents an attractive alternative to arthrodesis or amputation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 131 - 131
1 Mar 2012
Jaiswal P Park D Carrington R Skinner J Briggs T Flanagan A Bentley G
Full Access

Introduction

We report the initial 2 and 3 year follow-up results of this randomised controlled trial of autologous chondrocyte implantation (ACI) using porcine-derived collagen membrane as a cover (ACI-C) versus matrix-carried autologous chondrocyte implantation (MACI) for the treatment of osteochondral defects of the knee.

Methods

217 patients were randomised to have either ACI (92 patients) or MACI (125 patients). The mean age in each group was 35.1 and 33 years respectively. There were equal proportion of males and females and there was no difference in the size of lesions in each of the treatment groups. One year following surgery, patients underwent check arthroscopy (with or without biopsy) to assess the graft. Functional assessment was performed yearly by using the Modified Cincinatti Knee score, the SF-36 score, the Bentley Functional Rating Score and the Visual Analogue Score.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 122 - 122
1 Feb 2012
Gooding C Bartlett W Bentley G Skinnner J Carrington R Flanagan A
Full Access

The results for autologous chondrocyte implantation (ACI) in the treatment of osteochondral defects in the knee are encouraging. At present, two techniques have been described to retain the chondrocyte suspension within the defect. The first involves using a periosteal flap harvested from the distal femur and the second involves using a type I/III collagen membrane. To the authors' knowledge there are no comparative studies of these two techniques in the current literature.

A total of 68 patients with a mean age of 30.52 years (range 15 to 52 years) with symptomatic articular cartilage defects were randomised to have either ACI with a periosteal cover (33 patients) or ACI with a type I/III collagen cover (35 patients). The mean defect size was 4.54 cm2 (range 1 to 12 cm2). All patients were followed up at 24 months.

A functional assessment using the Modified Cincinnati score showed that 74% of patients had a good or excellent result following the ACI with collagen cover compared with 67% after the ACI with periosteum cover at 2 years (p>0.05). Arthroscopy at 1 year also demonstrated similar results for both techniques. However, 36.4% of the periosteum covered grafts required shaving for hypertrophy compared with 1 patient for the collagen covered technique.

This prospective, randomised study has shown no statistical difference between the clinical outcome of ACI with a periosteal cover versus ACI with a collagen cover at 2 years. A significant number of patients who had the ACI with periosteum technique required shaving of a hypertrophied graft within the first year of surgery. We conclude that there is no advantage in using periosteum as a cover for retaining the chondrocytes within an osteochondral defect; as a result we advocate the use of an alternative cover such as a porcine-derived, type I/III collagen membrane.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 155 - 155
1 Feb 2012
Krishnan S Skinner J Jaggiello J Carrington R Flanagan A Briggs T Bentley G
Full Access

Aims

To investigate (1) The relationship between macroscopic grading and durability of cartilage repair following collagen-covered autologous chondrocyte implantation (ACI-C) in the knee; (2) The influence of histology on durability of cartilage repair; (3) The relationship between macroscopic appearance and histology of repair tissue.

Patients and methods

The modified Cincinnati scores (MCRS) of eighty-six patients were evaluated prospectively at one year and at the latest follow-up (mean follow-up = 4.7yrs. Range = 4 to 7 years). Needle biopsies of their cartilage repair site were stained with Haematoxylin and Eosin and some with Safranin O and the neo-cartilage was graded as hyaline-like (n=32, 37.2%), mixed fibro-hyaline (n=19, 22%) and fibro-cartilagenous tissue (n=35, 40.7%). Macroscopic grading of the repair tissue using the international cartilage repair society grading system (ICRS) was available for fifty-six patients in the study cohort. Statistical analyses were performed to investigate the significance of histology and ICRS grading on MCRS at 1 year and at the latest follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 153 - 153
1 Feb 2012
Park D Krishnan S Skinner J Carrington R Flanagan A Briggs T Bentley G
Full Access

Purpose

We report on minimum 2 year follow-up results of 71 patients randomised to autologous chondrocyte implantation (ACI) using porcine-derived collagen membrane as a cover (ACI-C) and matrix-induced autologous chondrocyte implantation (MACI) for the treatment of osteochondral defects of the knee.

Introduction

ACI is used widely as a treatment for symptomatic chondral and osteochondral defects of the knee. Variations of the original periosteum-cover technique include the use of porcine-derived type I/type III collagen as a cover (ACI-C) and matrix-induced autologous chondrocyte implantation (MACI) using a collagen bilayer seeded with chondrocytes.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 472 - 472
1 Nov 2011
Macmull S Parratt M Bentley G Skinner J Carrington R Briggs T
Full Access

Autologous chondrocyte implantation (ACII) has been shown to have favourable results in the treatment of symptomatic chondral and osteochondral lesions. However, there are few reports on the outcomes of this technique in adolescents.

The aim was to assess functional outcome and pain relief in adolescents undergoing autologous chondrocyte implantation (ACI).

Thirty-one adolescent patients undergoing ACI or Matrix-assisted chondrocyte implantation (MACI) were identified from a larger prospective study. Mean age was 16.3 years (range 14 – 18) with a mean follow-up of 66.3 months (12–126 months).

There were 22 males and nine females. All patients were symptomatic; 30 had isolated lesions and one had multiple lesions. Patients were assessed pre and postoperatively using the Visual Analogue Score (VAS), the Stanmore/Bentley Functional Rating Score and the Modified Cincinnati Rating System.

The mean VAS improved from 5.8 pre-operatively to 2 post-operatively. The Stanmore/Bentley Functional Rating Score improved from 2.9 to 0.9 whilst the Modified Cincinnati Rating System improved from 49.8 pre-operatively to 81.3 postoperatively with 87% of patients achieving excellent or good results. All postoperative scores exhibited statistically significant improvement from pre-operative scores.

The results show that, in this particular group of patients, this procedure produces reduction in pain and a statistically significant improvement in function postoperatively. We strongly recommend this procedure in the management of adolescents with symptomatic chondral defects.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 298 - 298
1 Jul 2011
Briggs T Spiegelberg B Hanna S Tai S Gokaraju K Carrington R Pollock R Cannon S
Full Access

Metal-on-metal arthroplasties are being inserted in increasing numbers of younger patients due to the increased durability and reduced requirement for revision in these implants. Recent studies have raised many concerns over possible genotoxicity of MoM implants. This is a prospective study of patients who have undergone elective total hip replacement, they were selected and then randomised into two groups. Group A received a MoP implant and group B received a MoM implant. Patients are reviewed pre-operatively (control group), at 3 months, 6 months, 1 year and 2 years post-operatively. On each occasion blood tests are taken to quantify metal ion levels (chromium, cobalt, titanium, nickel and vanadium) using HR-ICPMS method and chromosome aberrations in T lymphocytes using 24 colour fluorescent in situ hybridisation (FISH).

Fiffty three patients have been recruited to date, 24 of whom had MoP prosthesis and 29 a MoM. 25 of these have had their one-year follow-up with blood analysis. Cobalt and chromium concentration increased during the first 6 months in both MoM and MoP groups, in the MoM group the chromium levels were twice that of MoP group and 12x that of the preoperative samples. There was no difference with the levels of titanium, nickel and vanadium. Chromosome aberrations occurred in both groups. At 6 months both the MoM and MoP groups showed increase frequency of aneuploidy aberrations with further increases after one year. Structural damage in the form of translocations occurred in the MoM group after one year, but not in the MoP group.

Preliminary results of this study show that the levels of chromium and cobalt are significantly higher in the MoM group compared to the MoP group. This corresponds to increases in chromosome aberrations between the groups particularly in translocations present in the MoM group at 1 year.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 292 - 292
1 Jul 2011
Parratt M Macmull S Gikas P Gokaraju K Carrington R Skinner J Bentley G Briggs T
Full Access

High Tibial Osteotomy (HTO) is a recognised method of correction for knee joint malalignment and unicom-partmental osteoarthritis. Long-term results of this technique have been reported and are favourable. Good results have also been reported with Autologous Chondrocyte Implantation (ACI-C, MACI). Malalignment, if present, should be corrected when ACI is performed. Although results have been reported for either procedure separately, the outcomes of combined HTO-ACI remain unreported. The aim of this study was to evaluate functional outcome in patients undergoing combined HTO-ACI procedures.

Twenty three patients undergoing a combined ACI-HTO procedure were identified retrospectively from a larger trial of patients undergoing ACI for symptomatic chondral defects. The mean age of the patients was 36 (28 – 49). The mean follow-up was 54 months (12 – 108) and mean defect size was 689mm2 (range 350 – 1200). Nine patients had ACI-C and HTO, the remainder having MACI and HTO. Pre and post-operative assessment was carried out using the Visual Analogue Score (VAS), the Bentley Functional Rating Score and the Modified Cincinnati Rating System.

The Mean VAS score improved from 7.4 (4 – 10) pre-operatively to 2.9 (0 – 6) post-operatively at the latest follow-up (p< 0.0001). The Bentley Functional Rating Score improved from 2.9 (2 – 4) to 1.8 (0 – 4), which was statistically significant (p< 0.0001). The Modified Cincinnati Rating System improved from 35.2 (20 – 49) pre-operatively to 68.7 (46 – 85) post-operatively (p< 0.0001). Fourteen patients underwent biopsy of the graft site at a mean of 13.7 months: 21% of biopsies were hyaline-like cartilage, 36% were mixed hyaline/fibrocartilage, 29 % were fibrocartilage and 14% were fibrous tissue.

Combining high tibial osteotomy with autologous chondrocyte implantation is an effective method of decreasing pain and increasing function in the short term. Further evaluation of this procedure is required.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 287 - 287
1 Jul 2011
Gikas P Parratt T Carrington R Skinner J Bentley G Briggs T
Full Access

Introduction: Autologous Chondrocyte Implantation (ACI) is a treatment option for symptomatic, full-thickness chondral/osteochondral injuries. Goals of surgery and rehabilitation include replacement of damaged cartilage with hyaline/hyaline-like cartilage, leading eventually to improved level of function. Intermediate and long-term results are promising in terms of functional improvement.

Purpose: To explore the hypothesis that non-hyaline cartilage repair tissue is associated with worse functional outcome and to assess whether the quality of the repair tissue formed following ACI improves with time post-surgery.

Methods and Results: Two hundred and forty eight patients who underwent ACI at our institution were studied, having had post-implantation biopsies of the repair tissue. Mean timing of biopsy was 14.8 months (range 3–55). 59 biopsies showed hyaline tissue (24%), 67 mixed hyaline and fibrocartilage (27%), 113 biopsies were fibrocartilage only (46%) and 9 patients had a fibrous tissue biopsy result (9%). 126 patients (51%) had hyaline tissue in the regenerate and demonstrated a mean Modified Cincinnati Rating Score (MCRS) of 84 and a mean Lysholm Score of 88 at last follow-up (Group 1). 122 patients (49%) had no hyaline tissue in the regenerate and scored a mean MCRS of 71 and a mean Lysholm Score of 73 (Group 2). Both Groups 1 and 2 demonstrated a statistically significant improvement in functional outcome between pre and post-operative scores (p< 0.0001). There was significant difference in post-operative scores between Groups 1 and 2 suggesting that presence of hyaline tissue in the regenerate is associated with improved functional outcome (p< 0.05). Finally, our statistical analysis suggested that if time post-implantation doubles, then the likelihood of a favourable histological outcome increases significantly.

Conclusion: ACI forms a durable repair tissue that remodels and continues to improve in quality with time. Poor functional outcome may reflect the presence of a non-hyaline cartilage repair tissue.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 287 - 287
1 Jul 2011
Jaiswal P Macmull S Bentley G Carrington R Skinner J Briggs T
Full Access

Introduction: Autologous chondrocyte implantation (ACI) has been used to treat patella cartilage lesions but several studies have indicated poorer results compared to lesions on the femoral condyles. This paper investigates the effectiveness of two different methods of ACI; porcine-derived collagen membrane as a cover (ACI-C) and matrix-carried autologous chondrocyte implantation (MACI).

Methods: 124 patients (mean age 33.5) with symptomatic osteochondral lesions in the patella were selected to undergo either ACI (56 patients) or MACI (68 patients). 1 year following surgery patients underwent check arthroscopy to assess the graft. Functional assessment was performed pre-operatively, at 6 months and yearly by using the modified Cincinnati score (MCS).

Results: 37.5% of patients experienced good or excellent clinical results according to the MCS in the ACI group compared with 69.2% in the MACI group (p = 0.0011). The mean MCS improved from 43.7 pre-operatively to 49.8 2 years following surgery in the ACI group, whereas in the MACI group the improvement was from 44.6 to 60.6 (p=0.07). Arthroscopic assessment showed a good to excellent International Cartilage Repair Society score in 89.7% of ACI-C grafts and 69.6% of MACI grafts (p = 0.08). There was a higher re-operation rate (p = 0.044) in the ACI group (29%) compared with MACI (10%).

Conclusions: The results from this paper suggest that MACI is more successful in the treatment of patella cartilage lesions than ACI even though arthroscopic assessment showed the converse to be true. The higher complication and re-operation rate suggests that we should be treating such patients with MACI.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 92 - 92
1 May 2011
Parratt M Nawaz Z Gikas P Carrington R Skinner J Bentley G Briggs T
Full Access

High tibial osteotomy (HTO) is a recognised method of correction for knee joint malalignment and unicompartmental osteoarthritis. The long term results of this technique have been reported and are favourable. Autologous chondrocyte implantation (ACI-C, MACI) has also been reported to have good results It is advised that malalignment, if present, should be corrected if ACI is to be performed. Although results have been reported for either procedure separately, the outcomes of combined HTO-ACI remain unreported.

To evaluate functional outcome in a group of patients undergoing combined HTO-ACI procedures.

Twenty three patients undergoing a combined ACI-HTO procedure were identified retrospectively from a larger trial of patients undergoing ACI for symptomatic chondral defects. The mean follow-up was 54 months (range 12 – 108) and the mean defect size was 689 mm2 (range 350 – 1200). Nine patients had ACI-C and HTO, the remainder having MACI and HTO. Pre and postoperative assessment was carried out using the Visual Analogue Score (VAS), the Bentley Functional Rating Score and the Modified Cincinnati Rating System.

The Mean VAS score improved from 7.4 pre-operatively to 2.9 post-operatively (p< 0.0001). The Bentley Functional Rating Score improved from 2.9 to 1.8 (p< 0.0001) whilst the Modified Cincinnati Rating System improved from 35.2 pre-operatively to 68.7 post-operatively (p< 0.0001). There was no significant difference between ACI-C and MACI. Two patients developed a non union at a mean of 13 months and a further two patients had a failure of the chondrocyte graft at a mean of 22.5 months.

Combining high tibial osteotomy with autologous chondrocyte implantation is an effective method of decreasing pain and increasing function at mean of 54 months follow-up. Further follow-up is required to assess the long term outcomes of these combined procedures.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 81 - 81
1 Jan 2011
Spiegelberg BGI Hanna SA Tai S Gokaraju K Carrington R Pollock R Cannon SR Briggs TWR
Full Access

Introduction: The aim of this study is to investigate whether MoM implants result in more chromosome aberrations and increased blood metal ions post-operatively when compared to MoP implants.

Large head metal-on-metal articulating surfaces of the hip are being used in increasing numbers of patients for oncological purposes due to the increased stability and reduced dislocation rate. Recent studies have raised many concerns over possible genotoxicity of MoM implants.

Methods: This is a prospective study of patients who have undergone elective total hip replacement. Patients were randomised into two groups (MoP and MoM). Patients are reviewed pre-operatively (control group), at 3 months, 6 months, 1 year and 2 years post-operatively. On each occasion blood tests are taken to quantify metal ion levels (chromium, cobalt, titanium, nickel and vanadium) using HR-ICPMS and chromosome aberrations in T lymphocytes using 24 colour fluorescent in situ hybridisation (FISH).

Results: 24 patients had MoP prosthesis and 29 a MoM. Cobalt and chromium concentration increased during the first 6 months in both MoM and MoP groups, in the MoM group the chromium levels were twice that of MoP group and 12x that of the preoperative samples. There was no difference with the levels of titanium, nickel and vanadium. Chromosome aberrations occurred in both groups. At 6 months both the MoM and MoP groups showed increase frequency of aneuploidy aberrations with further increases after one year. Structural damage in the form of translocations occurred in the MoM group after one year, but not in the MoP group.

Discussion: Results of this study show that the levels of chromium and cobalt are significantly higher in the MoM group compared to the MoP group. This corresponds to increases in chromosome aberrations between the groups particularly in aneuploidy and translocations present in the MoM group at 1 year.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 419 - 420
1 Jul 2010
Malikian R Maruthainar K Skinner J Carrington R Maruthainar N Cannon S Briggs T Dowd G Blunn G
Full Access

Purpose: To determine if Cobalt-Chrome (CoCr) femoral components of knee replacement components roughen significantly, and when significant roughening may start.

Methods:

Retrieval study:

14 knee replacement components were retrieved after revision procedures. The average surface roughness (Ra) of the articulating regions of each condyle was measured by surface profilometry and compared to Ra of non-articulating regions, which acted as controls on each implant.

In vitro testing:

Pin-on-plate testing of 6 paired CoCr pins and vacuum γ-irradiated UHMWPE discs was carried out under a force of 2.3kN at 1Hz to investigate how the articular Ra of CoCr pins varied with increasing number of cycles. Ra was measured at 0, 10, 100 and 1000 cycles using surface profilometry.

Results:

Retrieval analysis:

Average medial femoral condyle Ra was significantly greater than control Ra (p=0.040). Average lateral femoral condyle Ra was not significantly greater than control Ra (p=0.158). Significantly higher average Ra was seen on the medial condyles when compared with the lateral condyles (p < 0.05). 8/14 retrieved femoral components had ≥1 significantly roughened condyle (p< 0.05).

In vitro testing:

At 100 and 1000 cycles the Ra of the CoCr pins was significantly greater than Ra at 0 cycles (p< 0.05).

Conclusion: A large proportion of femoral components of knee replacement implants roughen significantly in vivo, a finding supported by our in vitro testing which indicates that roughening may begin very early on. This may have important implications for aseptic loosening of knee replacement components. However, the average Ra of those CoCr surfaces significantly (p< 0.05) roughened was within acceptable limits for orthopaedic implants (0.050μm).


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 392 - 392
1 Jul 2010
Spiegelberg B Hanna S Tai S Gokaraju K Pollock R Carrington R Cannon S Briggs T
Full Access

Introduction: Metal-on-metal arthroplasties are being used for their increased durability and reduced requirement for revision. Previous data reports that metal-on-metal bearing surfaces release three times more cobolt and chromium ions than metal-on-polyethelene hip replacements. Data also suggests that these metal ions can cause DNA damage.

Method: A prospective study of patients (aged 60–80), meeting exclusion criteria were selected and randomised to metal-on-metal or metal-on-polyethylene articulation. Patients were reviewed preoperatively (control model) and at 3 months, 6 months and one year postoperatively. On each occasion blood tests were taken to quantify metal ion levels (chromium, cobalt, nickel, vanadium and titanium) and chromosome aberrations in T lymphocytes using 24 colour fluorescent in situ hybridization (FISH).

Results: The number of chromosome aberrations increased with time; in particular there was a statistically significant increase in aneuploidy after one year, there was also an increase in chromosome translocations. There was a similar increase in blood concentration of metal ions over this same time period which proved significant. Higher levels of metal ions were seen in the metal-on-metal group when compared with the metal-on-polyethylene.

Conclusion: This study has highlighted the effects of metal ions on chromosome replication in particular causing aneuploidy aberrations. This provides evidence of the short-term effects of metal-on-metal arthroplasty but further research needs to be undertaken to assess long-term risk and also the risk associated to other cell lines.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 411 - 412
1 Jul 2010
Gikas P Carrington R Skinner J Briggs T Bentley G
Full Access

Introduction: Autologous Chondrocyte Implantation (ACI) is a treatment option for full-thickness chondral, or osteochondral injuries that are painful and debilitating. Goals of surgery and rehabilitation include replacement of damaged cartilage with hyaline or hyaline-like cartilage, leading eventually to improved level of function. Intermediate and long-term results are promising in terms of functional and clinical improvement.

Purpose: To explore the hypothesis that the quality of the repair tissue, formed following Autologous Chondrocyte Implantation (ACI), improves with time post-surgery.

Methods and Results: Two hundred and forty eight patients who underwent autologous chondrocyte implantation in our institution were studied after having had post implantation biopsies of the repair tissue. Mean timing of biopsy was 14.8 months (range 3–55). 59 biopsies gave hyaline tissue (24%), 67 mixed hyaline and fibrocartilage (27%), 113 biopsies were fibrocartilage only (46%) and 9 patients had a fibrous tissue biopsy result (9%). Due to NHS restraints and waiting list targets biopsies were actually performed at various time points post implantation allowing us to statistically correlate histological findings with the maturity of the repair tissue.

Our statistical analysis suggests that if time post implantation doubles then the likelihood of a favourable histological outcome increases significantly.

Conclusion: Autologous chondrocyte implantation forms a durable repair tissue that remodels and continues to improve in quality with time. It is recommended that for future research/study purposes 24 months is used as an optimal time to look at histology, since our data show that outcome is still improving until this point.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 317 - 317
1 May 2010
Bayliss L Jameson-Evans M Hanna S Gikas P Carrington R Briggs T Skinner J Bentley G
Full Access

Introduction: Initial results for the management of osteochondral defects with both ACI-C and MACI have been encouraging, showing significant clinical improvement. This single-centre study set out to determine any significant difference in outcomes between ACI-C and MACI.

Aim: Reporting three year follow up of clinical and arthroscopic assessment of prospective analysis of ACI-C and MACI used in the management of symptomatic, full-thickness chondral and osteochondral defects in the knee.

Method: Following assessment arthroscopy and harvesting of chondrocytes for culture, patients were randomised into the ACI-C or MACI arm and underwent their respective procedures one month later. In ACI-C a covered technique is employed using a porcine-derived type I/III collagen membrane sutured in place; MACI requires cultured autologous chondrocytes to be seeded in a bi-layered type I/III collagen membrane which is glued into position. An arthroscopy was performed at 12 and 24 months postprocedure to assess graft coverage and biopsies taken to determine extent of hyaline, mixed and fibro-cartilage proliferation.

Results: 102 patients underwent either ACI-C (44) or MACI (58) with an average age of 33.6 (14–52). Mean Cincinnati knee rating scores recorded prior to assessment arthroscopy for ACI-C: 45.2 (10 – 94) and MACI: 45.5 (10 – 90) showed improvement at follow up with 63% of patients in the ACI-C group scoring good or excellent at three years, and 60% in the MACI group. ICRS arthroscopy scores were good or excellent in 91.4% of ACI-C and 76.1% of MACI patients at 24 months. Biopsies of the transplants at 24 months revealed proliferation of hyaline and mixed cartilage (hyaline and fibro-cartilage) in 48.6% of the ACI-C and 30.5% of the MACI patients.

Conclusion: Results to date suggest significant clinical and arthroscopic improvement following ACI-C and MACI, with evidence of proliferation of hyaline cartilage at the transplant site. Limited differences are noted between the outcomes of the two techniques.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 321 - 322
1 May 2010
Jaiswal P Park D Carrington R Skinner J Briggs T Bentley G
Full Access

Purpose: We attempted to identify whether patients with early evidence of osteoarthritis (OA) on their pre-operative radiographs were associated with poorer outcomes after Autologous Chondrocyte Implantation (ACI).

Methods: We retrospectively reviewed radiographs of 94 consecutive patients who underwent ACI and had already had their knee function assessed according to the Modified Cincinatti Score 2 years following surgery. Changes were graded according to The Kellgren and Lawrence (K& L) and the Stanmore grading system. Two independent observers analysed the films to assess the reproducibility and accuracy of these grading systems for assessment of OA in the knee.

Results: Patients were divided into 2 groups; Group A were patients with excellent/good outcome (52 patients), those with fair/poor outcome were Group B (42 patients).13 patients in Group A and 21 patients in Group B had radiographic evidence of OA (p< 0.025). In 34 patients who had OA (mean age 33.6) the increase in Cincinatti score following surgery was minimal (33.5 to 37.5). In 60 patients where there was no evidence of OA (mean age 33.7) the score increased from 40 to 53.4. The inter-observer variation was greater using K& L (Kappa=0.31) compared with the Stanmore grading systems (Kappa=0.72).

Conclusions: Patients with early radiographic evidence of OA are unlikely to gain maximum benefit from ACI. Furthermore, we recommend the use of Stanmore grading system for the assessment of OA as it is more reproducible than the K& L grading system.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 298 - 298
1 May 2010
Gikas P Hanna S Bayliss L Aston W Jagiello J Carrington R Skinner J Briggs T Cannon S
Full Access

Introduction: The use of custom made CAD-CAM femoral stems in primary Total Hip Replacement allows preservation of valuable bone stock in anatomically challenging femora whilst optimising biomechanics and improving function. The custom prosthesis design and manufacturing process is carried out with the aid of computed tomography (CT), a system of tomographic image processing, a Computer–Aided Design (CAD) system and a Computer–Aided Manufacturing (CAM) system.

Aim: To report seven year minimum follow up of a custom made and designed femoral component used in total hip replacement, focusing on clinical and radiographic evidence of failure.

Methods: Patients who had an uncemented total hip arthroplasty, by one of the two senior authors, with a CAD-CAM hip between February 1993 and February 2000 were retrospectively studied. An independent observer evaluated all patients radiologically using Engh’s criteria of osteointegration and clinically using Harris and Oxford Hip Scores.

Results: 85 patients (47 male, 38 female) (102hips) underwent THA for a variety of reasons between February 1993 and February 2000. Average age was 53.7 (25.4–91.5). Average follow up was 9.3 years (7–15). The aetiologies for THA were: Developmental Dysplasia of Hip (22 hips), Osteoarthritis (25), Slipped Upper Femoral Epiphysis (3), Skeletal Dysplasia (11), Trauma (9), Perthe’s Disease (6), Avascular Necrosis (14), Tumour (4) and other (8). At last follow up 4 hips had been revised: 2 for aseptic loosening, 1 for deep infection and 1 for excessive acetabular cup liner wear. 84 patients were evaluated (one deceased from unrelated causes). Average Harris Hip Score was 81 (range 53–96). Average Oxford Hip Score was 24 (range15–43). A full set of x-rays was available for 73 patients and when evaluated all were radiographically stable. Endosteal bone formation or spots welds were present on all 73 of the x-rays. Radiolucent lines at the bone-implant interface were present on 7/73 x-rays but did not correlate with clinical problems. There was no evidence of bone pedestal formation.

Conclusions: Clinical results are good to excellent with little radiographic evidence of failure. CAD-CAM hips can be safely and reliably used for a variety of aetiologies with predictable result at least up to seven years postoperatively.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 124 - 124
1 Mar 2010
Parratt M Waters T Carrington R Skinner J Bentley G
Full Access

Orthopaedic surgeons vary in their attitude towards resurfacing of the patella in total knee arthroplasty. Few studies are available to assess outcome and patient preference. We evaluated post-operative anterior knee pain and knee preference in patients with bilateral knee replacements and unilateral patellar resurfacing.

We reviewed 30 patients who had undergone bilateral knee replacement with patellar resurfacing on only one side. Follow-up was from five to 12 years and the patients were assessed using the Knee Society rating, an anterior knee pain rating and a satisfaction score. Patients were also asked specifically if they had a preference for either knee. Assessment was performed without knowing which patella had been resurfaced.

Fourteen patients (47%) favoured the resurfaced knee, six (20%) the un-resurfaced knee and 10 (33%) had no particular preference. The overall prevalence of anterior knee pain was 50% in the un-resurfaced cases (six mild, six moderate, three severe) and 20% in the resurfaced knees (four mild, two moderate). No significant difference was found between knee scores. Three un-resurfaced patellae have been secondarily resurfaced.

This study shows a significant preference for the resurfaced side (p< 0.01), with a higher prevalence of anterior knee pain in non-resurfaced patellae (p< 0.05).


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 501 - 502
1 Sep 2009
Coltman T Chhaya N Briggs T Skinner J Carrington R
Full Access

Our aim was to review the short-term clinical results of a single-institution cohort undergoing opening wedge high tibial osteotomy (HTO).

We undertook a prospective clinical and radiographic review of our cohort of patients who had undergone opening wedge HTO for varus malalignment. The Cincinnati scoring system was used for objective assessment. Pre- and post-operative radiographs were evaluated and Blackburne-Peel (BP) and Insall-Salvati (IS) ratios recorded, as well as integrity of the lateral hinge.

We reviewed 55 knees (51 patients: 34 men and 17 women; mean age, 44.2years; range 34–58years) followed up for a minimum 12 months (range, 12–62months). All patients had relief of pain, but six met our criteria of failed treatment where either revision fixation was required or proceeded to total knee arthroplasty for persisting symptoms. Cincinnati scores were 94.5% excellent (52/55) and 5.5% good (3/55) at 1 year, whilst at last follow-up they were 87.2% excellent (48/55), 9.1% good (5/55) and 3.6% fair (2/55). There was a significant improvement in mean American Knee Society score at 1 year and maintained at last follow-up (p< 0.05). Radiographically the lateral hinge was noted to be breached in 9.1% (5/55), but no incidence of non-union was identified. There was no significant change in IS index, however BP index diminished by a mean 15.3% (range, 7.4–28.2%). Medial opening wedge tibial osteotomy results in patellar infera, but successful clinical and functional outcomes have been demonstrated. The fact ther e is inconsistency between the two indices assessing patellar height ratio we believe reflects the inherent variability in the techniques employed. Distalisation of the tibial tubercle will mean the IS ratio remains unaffected, whilst the BP index more accurately demonstrates the lowering of patella relative to the joint line. However there may be other factors which are not immediately appreciated, such as changes in the tibial inclination or antero-posterior translation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 409 - 410
1 Sep 2009
Bayliss L Gikas P Hanna S David L Aston W Carrington R Skinner J Cannon S Briggs T
Full Access

Introduction: We report our experience with use of the SMILES prosthesis in primary knee arthroplasty.

Methods: The Stanmore Modular Individualised Lower Extremity System (SMILES prosthesis) has been shown to be effective in complex revision knee surgery. It incorporates a rotating hinge platform knee joint and can overcome the major problems of bone loss and ligamentous laxity.

38 patients (41 knees) who received a primary SMILES knee prosthesis by one of the senior authors between 1990 and 2006 were retrospectively studied. Knee function was assessed pre and post-operatively using the Oxford knee score (0–48 scoring system) and the Knee Society Score. Patients receiving surgery for tumours were excluded. The main indications for primary SMILES were bone loss and ligamentous laxity.

Results: The minimum follow-up was 18 months with a mean of 5 years (1–17). The mean age of the patients was 57.7 years (23–86); 15 of the patients were male. The indications for surgery were trauma (12), osteoarthritis with deficient medial collateral ligament (8), polio (7), rheumatoid arthritis (5), epiphyseal dysplasia (4), achondroplasia (2), avascular necrosis (1), osteogenesis imperfecta (1) and ankylosing spondylitis (1).

2 patients died and 5 were lost to follow-up. 2 patients required revision surgery (one for infection and one for re-bushing). Post-operative complications included peroneal nerve palsy (1) and DVT (1). The mean Oxford knee score improved from 9 pre-op to 44 post-op, and the mean knee society score improved from 24 pre-op to 71 post-op. The average range of motion was 57 degrees pre-op and 88 degrees post-op.

Conclusion: We conclude that the SMILES prosthesis offers significant improvement in clinician and patient assessed outcome scores in complex primary knee arthroplasty. The cost compares favourably with other designs and its use is well established.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 501 - 501
1 Sep 2009
Coltman T Chhaya N Briggs T Skinner J Carrington R
Full Access

Our aim was to review the short-term clinical results of a single-institution cohort undergoing opening wedge high tibial osteotomy (HTO).

We undertook a prospective clinical and radiographic review of our cohort of patients who had undergone opening wedge HTO for varus malalignment. The Cincinnati scoring system was used for objective assessment. Pre- and post-operative radiographs were evaluated and Blackburne-Peel (BP) and Insall-Salvati (IS) ratios recorded, as well as integrity of the lateral hinge.

We reviewed 55 knees (51 patients: 34 men and 17 women; mean age, 44.2years; range 34–58years) followed up for a minimum 12 months (range, 12–62months). All patients had relief of pain, but six met our criteria of failed treatment where either revision fixation was required or proceeded to total knee arthroplasty for persisting symptoms. Cincinnati scores were 94.5% excellent (52/55) and 5.5% good (3/55) at 1 year, whilst at last follow-up they were 87.2% excellent (48/55), 9.1% good (5/55) and 3.6% fair (2/55). There was a significant improvement in mean American Knee Society score at 1 year and maintained at last follow-up (p< 0.05). Radiographically the lateral hinge was noted to be breached in 9.1% (5/55), but no incidence of non-union was identified. There was no significant change in IS index, however BP index diminished by a mean 15.3% (range, 7.4–28.2%). Opening wedge HTO provides a means of relieving stress distribution through the medial tibiofemoral compartment and results in effective relief of symptoms with improvement in functional outcome and quality of life.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 416 - 416
1 Sep 2009
Coltman T Chhaya N Briggs T Skinner J Carrington R
Full Access

Aim: To review the short-term clinical results of a single-institution cohort undergoing opening wedge high tibial osteotomy (HTO).

Method: We undertook a prospective clinical and radiographic review of our cohort of patients who had undergone opening wedge HTO for varus malalignment. The Cincinnati scoring system was used for objective assessment. Pre- and post-operative radiographs were evaluated and Blackburne-Peel (BP) and Insall-Salvati (IS) ratios recorded, as well as integrity of the lateral hinge.

Results: we reviewed 55 knees (51 patients: 34 men and 17 women; mean age, 44.2 years; range 34–58 years) followed up for a minimum 12 months (range, 12–62 months). All patients had relief of pain, but six met our criteria of failed treatment where either revision fixation was required or proceeded to total knee arthroplasty for persisting symptoms. Cincinnati scores were 94.5% excellent (52/55) and 5.5% good (3/55) at 1 year, whilst at last follow-up they were 87.2% excellent (48/55), 9.1% good (5/55) and 3.6% fair (2/55). There was a significant improvement in mean American Knee Society score at 1 year and maintained at last follow-up (p< 0.05). Radiographically the lateral hinge was noted to be breached in 9.1% (5/55), but no incidence of non-union was identified. There was no significant change in IS index, however BP index diminished by a mean 15.3% (range, 7.4–28.2%).

Discussion: Medial opening wedge tibial osteotomy results in patellar infera, but successful clinical and functional outcomes have been demonstrated. The fact there is inconsistency between the two indices assessing patellar height ratio we believe reflects the inherent variability in the techniques employed. Distalisation of the tibial tubercle will mean the IS ratio remains unaffected, whilst the BP index more accurately demonstrates the lowering of patella relative to the joint line. However there may be other factors which are not immediately appreciated, such as changes in the tibial inclination or antero-posterior translation.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1172 - 1177
1 Sep 2009
Gikas PD Morris T Carrington R Skinner J Bentley G Briggs T

Autologous chondrocyte implantation is an option in the treatment of full-thickness chondral or osteochondral injuries which are symptomatic. The goal of surgery and rehabilitation is the replacement of damaged cartilage with hyaline or hyaline-like cartilage, producing improved levels of function and preventing early osteoarthritis. The intermediate results have been promising in terms of functional and clinical improvement.

Our aim was to explore the hypothesis that the histological quality of the repair tissue formed after autologous chondrocyte implantation improved with increasing time after implantation.

In all, 248 patients who had undergone autologous chondrocyte implantation had biopsies taken of the repair tissue which then underwent histological grading. Statistical analysis suggested that with doubling of the time after implantation the likelihood of a favourable histological outcome was increased by more than fourfold (p < 0.001).


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 75 - 76
1 Mar 2009
bhadra A Krishnan S Young S Chaya N Carrington R Goldhill D Briggs T Skinner J
Full Access

Introduction: Blood management in the perioperative period of the total joint arthroplasty procedure has evolved over the last 3 decades. We performed two separate studies:

1) observational study to analyse surgeon’s and anaesthetist’s attitude to transfusion

2) prospective study to analyse the influence of perioperative haemoglobin concentration (Hb) on post-operative fatigue, hand grip strength, duration of in-patient physiotherapy and post-operative morbidity score (POMS) and also the prognostic factors to predict functional recovery.

Method: 500 orthopaedic surgeons and 336 anaesthetists were surveyed to assess current UK attitudes towards transfusion practice following arthroplasty.

200 patients (88 THR, 99 TKR, 13 hip resurfacing) were evaluated. Blood Hb, hand grip strength and vigour scores using fatigue questionnaire were estimated both preoperatively and at 3 days following surgery. POMS and the required duration of in-patient physiotherapy were also noted. The protocol for blood transfusion was for those with Hb less than 8 g/dL and/or post-operative symptoms attributable to anaemia.

Results: In an uncomplicated patient following total hip arthroplasty, 53.2% of surgeons and 63.1% of anaesthetists would transfuse at or below Hb of 8g/dL. Mean transfusion threshold in surgeons was 8.3g/dL compared to 7.9g/dL for anaesthetists (p< 0.01). 97% of surgeons transfused two or more units compared to 78% anaesthetists (p< 0.01). This threshold Hb increased if patient was symptomatic (surgeons 9.3g/dL, anaesthetists 8.8g/dL, p< 0.05), or if known to have pre-existing ischaemic heart disease (surgeons 9.0g/dL, anaesthetists 9.2g/dL, p< 0.05).

A greater fall in postoperative Hb correlated significantly with a greater reduction in post-operative vigour score (p=0.02). Also a greater fall in vigour score was found to correlate significantly with the duration of in-patient physiotherapy (p< 0.001). A reduction in Hb of > 4g/dL from the pre-operative Hb predicted a significantly higher reduction in vigour score (p=0.03). A weak correlation was seen between a fall in Hb and POMS (p=0.09).

A higher pre-operative Hb did not reduce the required duration of in-patient physiotherapy (p=0.72). There was no correlation between post-operative Hb and POMS (p=0.21) or duration of in-patient physiotherapy (p=0.20).

A higher pre-operative grip strength predicted an early date of discharge by the physiotherapists (p=0.02).

Conclusion: Haemoglobin level below 9g/dL is the most common ‘trigger’ for blood transfusion. Surgeons tend to be more aggressive in their attitude to transfusion. A fall in Hb of more than 4 g/dL has a detrimental effect on post-operative rehabilitation. Pre-operative grip strength measurements are valuable in predicting the rehabilitation potential of patients undergoing lower limb arthroplasty.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 84 - 84
1 Mar 2009
Jaiswal P Park D Jagiello J Carrington R Skinner J Briggs T Bentley G
Full Access

Introduction: Smoking is associated with impaired wound healing, delayed bony union following fractures and an adverse effect on the immune system. Furthermore, smoking is an important risk factor for the development pulmonary complications following major surgical procedures, as well as wound complications. We determined whether smoking had a deleterious effect on outcome after autologous chondrocyte implantation (ACI) in the treatment of ostechondral defects of the knee.

Methods: We identified 103 (54 females and 49 males) patients with a mean age of 34.2 (range 18 to 49) who had undergone ACI between January 2001 and August 2004 who also had their smoking status recorded. The patients were divided into 3 groups according to their smoking status. The Visual Analogue Score, Bentley Functional Rating Score and Modified Cincinatti Scores were used to assess function pre-operatively, 6 months and then yearly thereafter.

Results: Group 1 consisted of 31 smokers (mean pack years of 13.4), group 2 consisted of 63 non-smokers and group 3 contained 9 ex-smokers. In Group 1, the Modified Cincinatti Score pre-operatively, 6 months, 1 year and 2 years following surgery were 34.1, 42.6, 43.5 and 46.7 respectively. In group 2 the scores were 47.4, 59.6, 59.1, 65.3, and in group 3 the scores were 39.8, 50, 53.3, 51.8. At the 1 year check arthroscopy, the graft failure rate in group 1 was 12% and biopsies revealed mixed hyaline and fibrocartilage in only 25% (there were no patients with hyaline cartilage). There were no graft failures in group 2 and 43.8% of the biopsies performed were either hyaline (12.5%) or mixed hyaline and fibrocartilage (31.3%). The wound complication rate was 24% in group 1 and 8% in group 2.

Conclusions: The results of this study suggest that people who smoke have a worse functional outcome and a higher complication rate following chondrocyte implantation. This association has not been previously described and should be included in the pre-operative counselling of patients undergoing the procedure.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 84 - 84
1 Mar 2009
Jaiswal P Park D Jagiello J Carrington R Skinner J Briggs T Bentley G
Full Access

Introduction: Several studies have implicated excessive weight as a negative predictor of success of total knee arthroplasty. In addition, obese patients are known to have increased risk of wound complications after orthopaedic and general surgery. The purpose of this study was to compare the clinical and functional outcomes of autologous chondrocyte implantation for treatment of osteochondral defects of the knee performed in obese patients with those performed in non-obese patients.

Methods: We analysed the data on all our patients that have been followed up for a minimum of 2 years and had their height and weight recorded initially in our database. Functional assessment consisted of Bentley Functional Rating Score, Visual Analogue Score, and the Modified Cincinatti Scores (collected prospectively at 6 months, 1 year, 2 years and 3 years following surgery). Patients were placed into 3 groups according to their body mass index (BMI). Group A consisted of patients with BMI of 20 to 24.9, group B patients with BMI of 25 to 29.9 and Group C are patients with BMI of 30 to 39.9.

Results: There were 80 patients (41 males and 39 females) with a mean age of 35.4 (range 18 to 49). The mean BMI for the entire group was 26.6. The pre-operative, 6 month, 1 year, 2 year, and 3 year Modified Cincinatti Score in Group A (32 patients) was 54.4, 80.3, 82.7, 74.7 and 72.6. Similarly in Group B, the scores were 53, 41, 54, 56, 49.5 and in Group C the scores were 36.3, 36.3, 49.6, 36, and 35.7. The wound infection rate in Group A was 6.25%, in Group B was 17.6% and Group C was 14.3%.

Conclusions: Initial results from this study suggest that BMI is an important predictor of outcome after chondrocyte implantation. The group of patients that would gain most benefit from ACI are patients that are not overweight (defined by BMI in the range of 20 to 24.9). Further work is being carried out to support the hypothesis that surgeons should strongly consider not operating on patients unless the BMI is less than 25.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 84 - 84
1 Mar 2009
Jaiswal P Park D Carrington R Skinner J Briggs T Flanagan A Bentley G
Full Access

Introduction: ACI is used widely as a treatment for symptomatic chondral and osteochondral defects of the knee. Variations of the original periosteum-cover technique include the use of porcine-derived type I/type III collagen as a cover (ACI-C) and matrix-induced autologous chondrocyte implantation (MACI) using a collagen bilayer seeded with chondrocytes. We report the minimum 2 year follow-up results of 192 patients randomised to autologous chondrocyte implantation (ACI) using porcine-derived collagen membrane as a cover (ACI-C) and matrix-induced autlogous chondrocyte implantation (MACI) for the treatment of osteochondral decfects of the knee.

Methods: 192 patients (mean age 34.2) were randomised to have either ACI (86 patients) or MACI (106 patients). 1 year following surgery patients underwent check arthroscopy (with or without biopsy) to assess the graft. Functional assessment was performed yearly by using the modified Cincinatti knee score, the Bentley functional rating score and the visual analogue score.

Results: 24 patients were excluded from the study as they underwent additional procedures (e.g. high tibial osteotomy). In the ACI group the modified Cincinatti score increased from 42.5 pre-operatively to 56.7, 54.1, and 60.4 at 1 year, 2 years and 3 years respectively. In the MACI group the Cincinatti scores increased from 46.0 pre-operatively to 59.9, 58.9, and 58.4. Arthroscopic assessment showed a good to excellent International Cartilage Repair Society score in 90.7% of ACI-C grafts and 68.4% of MACI grafts. Hyaline-like cartilage or hyaline-like with fibrocartilage was found in biopsies of 51.9% of ACI-C grafts and 25.9% of MACI grafts.

Conclusions: ACI grafts are more likely to produce hyaline-like or mixed hyaline-like cartilage and fibro-cartilage with better ICRS grades than MACI grafts. However, this does not translate to better a clinical functional outcome. More importantly, ACI and MACI had similar results that were maintained at 3 years.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 51 - 52
1 Mar 2009
Skinner J Donaldson J Abuzakuk T Shenava Y Kumar S Jaiswal P Pollock R Carrington R Briggs T
Full Access

We aimed to determine whether proximal femoral bone remodelling, as measured by DEXA scan for each Gruen Zone, differed for 3 different femoral stem designs. These were:

Group 1 – Triple taper polished (C-stem J& J DePuy)

Group 2 – Double taper polished (TPS J& J DePuy)

Group 3 – Collared satin finish stem (Stanmore Biomet)

Ethical Committee approval was obtained and all patients gave informed consent. All operations were performed by 3 surgeons using a standard lateral approach, third generation cementing technique and a standard post-operative regime.

Seventy-five patients were randomised prospectively using a stratified randomisation programme for known risk factors in bone density. The randomisation was stratified by age, sex, Charnley Group (A or B), BMI and femoral neck bone mineral density. There were 25 patients in each Group, 5 patients did not have complete data sets and were therefore withdrawn from evaluation.

The Groups were similar with regard to age, sex, BMI, BMD and Charnley Group. Patients were followed up at 3, 6, 12 and 24 months by Nurse Practitioners for clinical and radiological evaluation and DEXA scan at each time of follow-up. There were no catastrophic failures of sepsis or dislocation. All patients functioned well at 24 months by Harris Hip Score.

The bone remodelling pattern will be described for each stem design. Findings are summarised thus. In the lateral Gruen Zones the triple taper and collared stem design faired better and both behaved differently to the double taper design. In Gruen Zone 7, all stems demonstrated reduced bone density as compared to pre-operative scans but this was less with the triple taper design.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 578 - 578
1 Aug 2008
Jaiswal P Jameson-Evans M Jagiello J Carrington R Skinner J Briggs T Bentley G
Full Access

Aims: To compare the clinical and functional outcomes of autologous chondrocyte implantation for treatment of osteochondral defects of the knee performed in overweight, obese and patients of ‘ideal weight’as defined by their BMI.

Methods: We analysed the data on all our patients that have been followed up for a minimum of 2 years and had their height and weight recorded initially in our database. Functional assessment consisted of the Modified Cincinatti Scores (collected prospectively at 6 months, 1 year, 2 years and 3 years following surgery). Patients were placed into 3 groups according to their body mass index (BMI). Group A consisted of patients with BMI of 20 to 24.9, group B patients with BMI of 25 to 29.9 and Group C are patients with BMI of 30 to 39.9.

Results: There were 80 patients (41 males and 39 females) with a mean age of 35.4 (range 18 to 49). The mean BMI for the entire group was 26.6. The pre-operative, 6 month, 1 year, 2 year, and 3 year Modified Cin-cinatti Score in Group A (32 patients) was 54.4, 80.3, 82.7, 74.7 and 72.6. Similarly in Group B, the scores were 53, 41, 54, 56, 49.5 and in Group C the scores were 36.3, 36.3, 49.6, 36, and 35.7. The wound infection rate in Group A was 6.25%, in Group B was17.6% and Group C was 14.3%.

Conclusions: Initial results from this study suggest that BMI is an important predictor of outcome after chon-drocyte implantation. The group of patients that would gain most benefit from ACI are patients that are not overweight (defined by BMI in the range of 20 to 24.9). Further work is being carried out to support the hypothesis that surgeons should strongly consider not operating on patients unless the BMI is less than 25.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 391 - 391
1 Jul 2008
Krishnan S Skinner J Jagiello J Carrington R Flanagan A Briggs T Bentley G
Full Access

Aims: To investigate

the influence of histology on durability of cartilage repair following collagen-covered autologous chon-drocyte implantation (ACI-C) in the knee.

the relationship between macroscopic grading and durability of cartilage repair; and

the relationship between macroscopic appearance and histology of repair tissue.

Patients and methods: The modified Cincinnati scores (MCRS) of eighty-six patients were evaluated prospectively at one year and at the latest follow-up (mean follow-up = 4.7yrs. Range = 4 to 7 years). Biopsies of their cartilage repair site were stained with Haema-toxylin and Eosin and some with Safranin O and the neo-cartilage was graded as hyaline-like (n=32), mixed fibro-hyaline (n=19) and fibro-cartilagenous tissue (n=35). Macroscopic grading of the repair tissue using the international cartilage repair society grading system (ICRS) was available for fifty-six patients in this study cohort. Statistical analyses were performed to investigate the significance of histology and ICRS grading on MCRS at 1 year and at the latest follow-up.

Results: The MCRS of all three histology groups were comparable at one year evaluation (p=0.34). However, their clinical scores at the latest follow-up showed a significantly superior result for those with hyaline-like repair tissue when compared to those with mixed fibro-hyaline and fibro-cartilagenous repair (p=0.05).

There was no correlation between the ICRS grading and MCRS either at one year (p=0.12) or at the latest follow-up (p=0.16). Also, the ICRS grading of the repair tissue did not correlate with its histological type (p=0.12).

Conclusion: We conclude that any form of cartilage repair gives good clinical outcome at one year. At four years and beyond, hyaline-like repair tissue produces a more favourable clinical outcome. Macroscopic evaluation using the ICRS grading system does not reflect the clinical outcome or its durability or the histological type of repair tissue.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 393 - 393
1 Jul 2008
Park D Krishnan S Skinner J Carrington R Flanagan A Briggs T Bentley G
Full Access

Purpose: We report on minimum 2 year follow-up results of 71 patients randomised to autologous chon-drocyte implantation (ACI) using porcine-derived collagen membrane as a cover (ACI-C) and matrix-induced autologous chondrocyte implantation (MACI) for the treatment of osteochondral defects of the knee.

Introduction: ACI is used widely as a treatment for symptomatic chondral and osteochondral defects of the knee. Variations of the original periosteum-cover technique include the use of porcine-derived type I/type III collagen as a cover (ACI-C) and matrix-induced autolo-gous chondrocyte implantation (MACI) using a collagen bilayer seeded with chondrocytes.

Results: 71 patients with a mean age of 33 years (15–48) were randomised to undergo either an ACI-C or a MACI. 37 had ACI-C and 34 MACI. The mean size of the defect was 5.0cm2. Mean duration of symptoms was 104.4 months (9–456). Mean follow-up was 33.5 months (24–45). Functional assessment using the modified Cincinnati knee score, the Bentley functional rating score and the visual analogue score was carried out. Assessment using the modified Cincinnati knee score showed a good to excellent result in 57.1% of patients followed up at 2 years, and 65.2% at 3 years in the ACI-C group; and 63.6% of patients at 2 years, and 64% at 3 years in the MACI group. Arthroscopic assessments showed a good to excellent International Cartilage Repair Society score in 81.8% of ACI-C grafts (22 patients) and 50% of MACI grafts (6 patients). Fisher’s exact test showed a p value of p=0.35 (not statistically significant). Hyaline-like cartilage or hyaline-like cartilage with fibrocartilage was found in biopsies of 56.3% of the ACI-C grafts (9 out of 16 patients) and 30% of the MACI grafts (3 out of 10 patients) after 2 years. Fisher’s exact test showed a p value of p=0.25 (not statistically significant).

Conclusion: At this stage of the trial we conclude that the clinical, arthroscopic and histological outcomes are comparable for both ACI-C and MACI.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 323 - 324
1 Jul 2008
Krishnan S Skinner J Jagiello J Carrington R Flanagan A Briggs T Bentley G
Full Access

Aim: The aim of this study was to correlate the histology of cartilage repair site with long term clinical function.

Materials and methods: We have analyzed the clinical results of a cohort of patients who had collagen-covered autologous chondrocyte implantations performed since 1998. Our hypothesis was that the hyaline cartilage repair does influence the clinical outcome.

The modified Cincinnati scores (MCRS) of eighty-six patients were evaluated prospectively at one year and at the latest follow-up following ACI-C (mean follow-up= 4.7 years. Range= 4 to 7 years). All these patients underwent biopsies of their cartilage repair site performed at variable periods between six months and five years following ACI-C (mean=22.2 months). The neo-cartilage was graded as hyaline (n=32), mixed fibrohyaline (n=19), fibrocartilagenous (n=35) and fibrous (n=0).

Results: The clinical results showed that at one year, the percentage of patients with excellent and good results was 84.4, 89.5 and 74.3 respectively for those with hyaline, mixed fibro-hyaline and fibro-cartilagenous histology respectively. Their mean MCRS were 70.8, 72.4 and 66.2 respectively. This difference was not statistically significant (p=0.34).

However, their clinical scores at the latest follow-up demonstrated a significantly superior result for those with hyaline repair tissue when compared to those with mixed fibro-hyaline and fibro-cartilagenous repair tissue (p=0.05). The percentage of patients with excellent and good results for those with hyaline, mixed fibro-hyaline and fibro-cartilagenous repair was 75, 42 and 68.6 respectively. Their mean MCRS were 70.6, 56.8 and 63.9 respectively.

Conclusion: This study demonstrates that any form of cartilage repair would give good clinical outcome at one year. At four years and beyond, it appears that patients with hyaline repair tissue tend to show a more favourable clinical outcome whereas those who demonstrated mixed fibrohyaline and fibrocartilagenous repair would show less favourable clinical results.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 390 - 390
1 Jul 2008
Krishnan S Bhadra A Chayya N Skinner J Carrington R Briggs T Goldhill D
Full Access

Introduction and Aims: Allogenic blood transfusion is often required in lower-limb arthroplasty. The aims of this study were (1) to analyze the influence of anaemia on post-operative fatigue, hand grip strength, duration of in-patient physiotherapy and post-operative morbidity score (POMS) and (2) to investigate for prognostic factors to predict functional recovery following primary arthroplasty of the lower limb.

Patients and methods: This study was approved by the regional ethics committee. Two hundred patients (88 THR, 99 TKR and 13 hip resurfacing) were evaluated in this prospective trial. Blood haemoglobin concentration (Hb), hand grip strength and vigour scores using a validated fatigue questionnaire were estimated both preoperatively and at 3 days following surgery. Postoperative morbidity score (POMS) and the required duration of in-patient physiotherapy were also noted. The protocol for blood transfusion was for those with Hb less than 8 g/dL and/or post-operative symptoms attributable to anaemia.

Results: A greater fall in postoperative Hb correlated significantly with a greater reduction in post-operative vigour score (p=0.02). Also a greater fall in vigour score was found to correlate significantly with the duration of in-patient physiotherapy (p< 0.001). A reduction in Hb of > 4g/dL from the pre-operative Hb predicted a significantly higher reduction in vigour score (p=0.03). A weak correlation was seen between a fall in Hb and POMS (p=0.09).

A higher pre-operative Hb did not reduce the required duration of in-patient physiotherapy (p=0.72). There was no correlation between post-operative Hb and POMS (p=0.21) or required duration of in-patient physiotherapy (p=0.20).

A higher pre-operative grip strength predicted an early date of discharge by the physiotherapists (p=0.02).

Conclusion: We conclude that a fall in Hb of more than 4 g/dL has a detrimental effect on post-operative rehabilitation. Pre-operative grip strength measurements are valuable in predicting the rehabilitation potential of patients undergoing lower limb arthroplasty.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 242 - 243
1 May 2006
Krishnan S Carrington R Jeffery R Thevendran G Garlick N
Full Access

Functional evaluations using the Harris hip scoring system and the delayed Trendelenberg test were performed on fifty randomly selected patients who had undergone cemented primary CPT total hip replacements (Zimmer UK) at least 12 months previously using Hardinge approach. The prosthesis used increases offset with femoral stem diameter but did not allow separate correction of neck offset.

Patients were grouped according to whether hip offset had been accurately reconstructed, increased or decreased. Their functional outcomes were compared. There was no significant difference (p value 0.57) in the final functional outcome between the three groups. Reconstruction of the hip using a standard cemented CPT prosthesis produced considerable variation in the reconstructed hip arthroplasty offset. This resulted in no functionally significant effect.

Accurate reconstruction of the hip joint offset in total hip arthroplasty may therefore not be as important in the early functional outcome as recently advocated.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 254 - 255
1 May 2006
Bartlett W Lee C Carrington R Cohen A Skinner J
Full Access

Purpose: The purpose of this study was to use the thromboelastogram to determine whether autologous blood transfusion following primary total knee replacement surgery results in an alteration to systemic coagulation.

Methods: 44 patients were randomised to receive either Hartmann’s solution alone postoperatively (control group), or Hartmann’s solution and autologous blood at six hours (ABT group). Thromboelastogram measurements of systemic blood clotting were performed pre-operatively, and post operatively at 6h just prior to the commencement of the ABT, 6h 30mins, and 8h.

Results: At 8h post operation (2h post ABT), the ABT group when compared with the control group showed an earlier onset of coagulation (3.83 minutes versus 4.49 minutes, p=0.003) and the formation of a stronger clot as assessed by the TEG maximum amplitude (maximum clot strength 83.9mm versus 75.9mm, p< 0.001).

Conclusion: The transfusion of drained autologous blood following total knee replacement may lead to an exaggerated hypercoagulable postoperative state. Further investigation of this potentially serious consequence of autologous blood transfusion is required.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 114 - 114
1 Mar 2006
Bartlett W Gooding C Amin A Skinner J Carrington R Flanagan A Briggs T Bentley G
Full Access

Background: Autologous chondrocyte implantation (ACI) was introduced over 15 years ago as a treatment for full-thickness chondral defects in the knee. Current understanding of ACI graft morphology and maturation in humans is limited. The aims of this study were determine the incidence of hyaline-like repair following ACI, and to clarify the relationship between repair morphology and clinical outcome.

Methods: A retrospective review of 194 ACI graft biopsies from 180 patients, and their clinical outcome was conducted. 154 Biopsies were performed 1 year after implantation and 40 biopsies were performed at 2 years. Three techniques of ACI implantation were used; Collagen covered ACI (ACI-C), periosteum covered ACI (ACI-P) and Matrix-Induced ACI (MACI).

Results: At 1 year, hyaline repair tissue was found in 48 (53%) ACI-C grafts, 7 (44%) ACI-P grafts, and 12 (36%) MACI grafts. The frequency of hyaline tissue found in biopsies performed at 2 years (84%) was significantly higher than those performed at 1 year (48.6%), p=0.0001, suggesting that grafts continue to remodel after the first year post implantation.

Clinical outcomes during the first two postoperative years did not vary according to repair morphology type, though hyaline repair was associated with better clinical outcomes beyond 2 years; At 1 year, good to excellent clinical scores were observed in 29 (78.4%) patients with hyaline-like repair, 23 (76.7%) patients with fibrohyaline repair, and 54 (74.0%) patients with fibrocartilage repair. By years 3 and 4 post-implantation, clinical scores further improved in patients with hyaline-like repair yet declined in those with fibrocartilage and fibrohyaline. The difference was significant at 3 years though not at 4 due to the small number of cases.

Conclusions: Achieving hyaline-like repair is critical to the longevity of cartilage repair. The finding of hyaline-like cartilage or fibrohyaline cartilage in 31 of 37 biopsies (84%) performed after 2 years is therefore encouraging and supports further use of the ACI technique.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 114 - 114
1 Mar 2006
Bartlett W Gooding C Skinner J Carrington R Flanagan A Briggs T Bentley G
Full Access

Background: Autologous Chondrocyte Implantation (ACI) is widely used as a treatment for symptomatic chondral and osteochondral defects of the knee. Variations of the original periosteum cover technique include the use of porcine-derived type I/III collagen as a cover (ACI-C), and the use of a collagen bilayer seeded with chondrocytes (MACI).

Aim: To determine whether differences in clinical, arthroscopic and histological outcomes at 1 year exist between ACI-C and MACI techniques.

Methods: We have performed a prospective randomised comparison of ACI-C versus MACI for the treatment of symptomatic chondral defects of the knee on 91 patients of whom 44 received ACI-C and 47 received MACI grafts.

Results: Both treatments resulted in improvements of clinical scores after 1 year. Mean modified Cincinnati knee scores increased by 17.5 in the ACI-C group and 19.6 in the MACI group (p> 0.05). Arthroscopic assessments performed after 1 year demonstrated good to excellent ICRS graft repair scores in 79% of ACI-C grafts and 67% of MACI grafts. Hyaline-like or hyaline-like cartilage with fibrocartilage was found in the biopsies of 43% of ACI-C grafts and 36% of MACI grafts after 1 year. The rate of graft hypertrophy was 9% in the ACI-C group and 6% in the MACI group. The frequency of re-operation was 9% in each group.

Conclusions: We conclude that clinical, arthroscopic and histological outcomes are comparable for both ACI-C and MACI techniques. While the MACI technique is technically attractive, further long-term studies are required before widespread adoption of this new technique.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 322 - 322
1 Sep 2005
Gooding C Bentley G Carrington R Briggs T Skinner J
Full Access

Introduction and Aims: ACI (autologous chondrocyte implantation) using a periosteum cover was developed by Peterson et al. Recently, the technique has been developed using a Type I/Type III collagen membrane (Chondro-Gide). A second technique MACI (matrix-induced autologous chondrocyte implantation) has evolved using a membrane with chondrocytes seeded onto its surface. Aim is to review the one and two-year results of the first 159 patients at a single regional centre.

Method: The two-stage procedure was performed with a standardised, progressive rehabilitation program. Patients were assessed clinically at three, six, nine, 12 and 24 months (pain score, Modified Cincinnati, Bentley), and arthroscopically at 12 and 24 months.

Results: 159 patients have been assessed at one year and 101 patients at two years. Of those patients reviewed at one year, 110 patients had the ACI repair with Chondro-Gide, 31 patients had the ACI repair with periosteum and 18 patients had the MACI repair. Sixty-nine percent had good or excellent results at one year and 60% at two years.

These figures represent the early results of this study performed at this unit.

Conclusion: We propose that the ACI technique is valuable for selected patients with Chondral and osteochondral defects of the knee even with large and multiple defects in the articular cartilage.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 344 - 345
1 Sep 2005
Beard D Bentley G Carrington R Briggs T Skinner J
Full Access

Introduction and Aims: Uni-compartmental knee arthroplasty (UKA) is appropriate for one in three osteoarthritic knees requiring replacement. An accelerated protocol enables patients undergoing UKA to be discharged within 24 hours of surgery. Before such an approach is universally accepted it must be safe, effective and economically viable. A study was performed to compare the new accelerated protocol with current standard care in a state healthcare system.

Method: A single blind RCT design was used. Patients eligible for UKA were screened for NSAID tolerance, social circumstances and geographical location before allocation to either an accelerated recovery group (Group A) or a standard non-accelerated group (Group S). The accelerated protocol included dedicated pain management and discharge support. Primary outcome was the Oxford Knee Assessment at six months post-operation, compared using independent t tests. Pain, range of movement and incidence of complications were also recorded by assessors blind to group allocation. Cost effectiveness was calculated in quality life adjusted years (QLAY) using the Euroqual instrument. The study power was sufficient to avoid type 2 errors. The study was supported by a NHS Regional R& D grant.

Results: Forty-one patients (21 group A, 20 group S) were included. Groups had comparable age and patient profiles. Average discharge time was 37 hours (1.5 days) for group A and 114 hours (4.3 days) for group S. Pain on hospital discharge was similar for both groups. No significant difference was found between groups for pain or range of movement at any time, although patients in group S regained pre-operative flexion faster than group A. One major complication occurred in each group; one infection (group S) and one manipulation for poor movement (group A). The cost per QLAY for the new protocol was 59% of the standard care.

Conclusion: The new protocol allows for safe accelerated discharge from hospital after UKA. The approach is cost-effective and should help to increase the throughput of patients who require knee replacement.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 354 - 354
1 Sep 2005
Krishnan S Morris R Garlick N Carrington R
Full Access

Introduction and aims: Increasingly the accurate reconstruction of the hip in total hip arthroplasty is planned using pre-operative pelvic radiographs. The accuracy of reconstruction is assessed using post-operative pelvic radiographs. This study defines significant variations in the offset, hip joint centre and femoral head centre-trochanteric height relations in normal radiographs.

Method: One hundred standard normal pelvic radiographs were examined based on a defined criterion. The medial offset, the vertical height of hip joint centre with reference to the ischial tuberosity and the femoral head centre-trochanterc height relation were measured for both hips. The differences in measurements were evaluated to determine the normal variation in offset and the hip joint centre. The relationship of the femoral head centre to the tip of the greater trochanter was determined.

Results: On average, the right hip and left hip differed by 2.54mm in their offset .The standard deviation of differences was 2.31. Therefore the offset of one hip will predict the offset of the other hip to within 4.62mm, with 95% accuracy. If the reconstructed hip has an offset to within + 4.62 to – 4.62mm of the contra lateral side, then the offset should be considered to be reconstructed as normal. The average difference in height of the hip joint centres of right hip from left hip with reference to bi-ischial line was found to be 3.49mm. The standard deviation of differences was 3.15. Therefore the hip joint centre height measured in one hip will predict the hip joint centre height of the opposite hip to within 6.3mm with 95% accuracy. Thus the hip joint centre height of one hip may differ from the opposite hip by 6.3mm in normal individuals. The tip of greater trochanter was on average 8mm higher than the centre of rotation of the femoral head. The greater trochanter was not at the same level as the femoral head centre as commonly believed.

Conclusion: This study demonstrates considerable variation in the medial offset and the hip joint centre location on pelvic wall. The femur head centre is lower than commonly assumed. These factors should be taken into account when pre-operative planning using pelvic radiographs and assessing the quality of the post-operative reconstruction.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 263 - 263
1 Mar 2004
Carrington R Skinner J Lewis A Bentley G
Full Access

Aims: The objective of this study was to clinically assess the outcome of CADCAM femoral components in the revision hip replacement. Methods: Between 1991 and 2000, 125 revision total hip replacements using CAD-CAM femoral components were performed. Clinical assessment was performed using the Harris Hip score, by direct patient consultation, and telephone or postal questionnaire. Survivorship was defined as the requirement for revision. Results: The patients were reviewed at a mean of 5.2 yrs (1 to 10)

The mean Harris hip score increased from 44 points (range, 27 to 71 points) preoperatively to 71 points (range, 21 to 98 points) at the time of the most recent follow-up. 9 patients required subsequent revision; 4 for aseptic loosening, 1 for septic loosening and 4 for fracture of the femoral component. Conclusions: CAD-CAM technology provides a viable alternative to the challenge of revision hip surgery, with results comparable to other cementless techniques.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 105 - 105
1 Feb 2003
Bentley G Biant LC Hunter M Nicolau M Carrington R Williams A Goldberg A Akmal M Pringle J
Full Access

Mosaicplasty1 and Autologous Chondrocyte Implantation2 (ACI) are both modern cartilage repair techniques used to repair symptomatic articular cartilage defects in the knee, based on small osteochondral grafts and cultured chondrocytes respectively. The aim is the restoration of articular cartilage, but until now there is no data comparing the two methods.

100 consecutive patients aged 15–45 with a symptomatic articular cartilage lesion in the knee suitable for cartilage repair were randomised at arthroscopic assessment to undergo either mosaicplasty or ACI. 42 patients underwent mosaicplasty, 58 had ACI. Mean age at time of surgery was 31 years and the average defect size 4. 66 cm2.

46% of the defects were post-traumatic, 19% had osteochondritis dissecans, 14% had chondromalacia patella and 16% had lesions of unknown aetiology. 53% had a medial femoral condyle lesion, 25% patella, 18% lateral femoral condyle, 3% trochlea and there was one defect of the lateral tibial plateau.

The mean duration of symptoms was 7. 2 years and the average number of previous operations (excluding arthroscopies) was 1. 5. Only 6 patients had no prior surgical interventions to the affected knee. The mean follow-up was 1. 7 years.

Patients were evaluated using Modified Cincinnati and Stanmore Functional rating systems, visual analogue scores and clinical assessment. Arthroscopy and biopsy was performed at one year and repair assessed with the International Cartilage Repair Society grading system.

Clinical results at one year showed 70% of mosaic-plasty patients and 87% of ACI patients had a good or excellent result. Arthroscopy at one year demonstrated more complete healing in ACI patients. Eleven (26%) of the mosaicplasty group subsequently failed clinically and arthroscopically, with peak failure at 2 years.

At one year follow-up, both techniques of articular cartilage repair can be useful in selected patients. ACI is preferred for lesions of the patella. Long-term follow-up is needed to assess the durability of articular cartilage repair using these methods, in particular mosaicplasty which showed signs of progressive failure over 2 years.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 106 - 106
1 Feb 2003
Bentley G Hunter M Biant LC Nicolau M Carrington R Williams A Goldberg A Akmal M Pringle J
Full Access

Autologous Chondrocyte Implantation’ (ACI) is a cartilage repair technique that involves implantation of cultured chondrocytes beneath a membrane of autologous periosteum. In this study a porcine biodegradable membrane was also used to assess its effectiveness. The aim is to restore articular cartilage to symptomatic defects, rather than initiating a fibrocartilagenous repair.

We undertook a prospective study of 125 consecutive patients who underwent ACI. Average age at the time of surgery was 30. 9 years (range 14 – 49), 55% of patients were male. The average size of the defect was 4. 35 cm².

44% of defects were attributable to known traumatic incidents, 2 1 % had osteochondritis dessicans, 18% chondromalacia patella, 12% had defects of unknown aetiology and 5% other.

The average duration of symptoms prior to this surgery was 7. 16 years. The mean number of previous operations (excluding arthroscopies) was 1. 6. Only 9 patients had no previous major surgery to the affected knee. 44% had defects of the medial femoral condyle, 31% patella, 20% lateral femoral condyle and 5% had a trochlea lesion. 26% of the defects were covered with periosteum and 74% with a porcine collagen membrane (chondrogide)

Minimum follow-up was six months, 70 patients had minimum follow-up of one year. Mean follow-up 18 months.

Patients were assessed using Modified Cincinnati and Stanmore Functional rating systems, visual analogue scores and clinical evaluation.

Arthroscopy and biopsy was performed at one year and the repair assessed using the International Cartilage Research Society grading system.

At one year follow-up overall 41 % patients had an excellent result, 48% good, 8% fair and 3% poor. For defects of the medial femoral condyle, 88% had a good or excellent result, 85% for the lateral femoral condyle and 80% for the patella.

61 patients were arthroscopically assessed at one year. 50/61 (82%) demonstrated ICRS grade 1 or 2 repair. Healing of the defect occurred with either a periosteum or chondrogide defect cover.

Results at one year suggest that ACI is a successful articular cartilage repair technique in selected patients. Long-term follow-up is required to assess the durability of the repair.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 242 - 242
1 Nov 2002
Bentley G Goldberg A Biant L Hunter M Carrington R
Full Access

Many methods have been described over the past 5 years for repair of articular cartilage defects. The best reported results have been from the use of autologous chondrocyte transplantation (ACT)(1) and mosaicplasty.(2) There have, however, been no prospective clinical trials of these two methods. In this trial 70 patients were prospectively randomized to receive either autologous chondrocyte transplantation (37) or mosaicplasty (33) in the knee. 37 patients were female and 33 male. The average age was 32 years (16 – 44). The indications for surgery were persistent pain and mechanical symptoms in the knee with an isolated defect of the articular cartilage. 38 (56%) were post-traumatic, 12 (16%) due to osteochondritis dissecans, 10 (14%) due to previous meniscectomy, and 10 (14%) due to chondromalacia patellae. The size of the defects ranged from 2cm2 to 12cm2 (mean 4.8cm2). There were 35 defects on the medial femoral condyle, 13 on the lateral femoral condyle, 17 on the patella and 5 on the trochlear. 31 patients were undergoing primary surgery and 39 secondary surgery. All were independently reviewed using the Visual Analogue Pain Score, the Cincinatti Pain Score and the Stanmore Score. Patients were arthroscoped at one year with MRI scan and biopsies where possible.

Results: The visual analogue pain score improved overall from a mean of 5.4 (range 3.4 – 7.4) pre-operatively to 3.9 (1.8 – 5.1) at one year review. Similarly the Cincinatti pain score improved from 6.5 pre-operatively to 10.2 post-operatively and the Cincinatti function score improved from 46 to 62 at one year before sport commenced. Overall 71% (49) patients were excellent or good on the clinical scoring scales, 15% (11) were fair, and 14% (10) were poor. The 10 poor results were no different from the main group with regard to age, sex, pain level or site or size of lesion. However, 5 were secondary procedures, 2 had multiple lesions, and 3 had had previous ruptured anterior cruciate ligaments. Arthroscopy and biopsy of 21 lesions so far after one year has shown mature articular cartilage in 2, and immature cartilage in 19. In all cases there was bonding of the repair tissue to the underlying bone. This study is already clarifying the role of ACT and mosaicplasty in the management of cartilage defects in the knee and also the necessity for the use of periosteal covering membrane.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 117 - 118
1 Jul 2002
Biant L Carrington R Tsui J Garlick N
Full Access

This study examined the reliability of pre-operative templating of the femur in total hip replacement (THR), and the accuracy of the templates provided by leading arthroplasty manufacturers. Templates are provided by arthroplasty manufacturers to be used with pre-operative radiographs as an aid to selecting the appropriate size of prosthesis that will allow an optimal cement mantle in THR. These templates vary in magnification from 10-20% (Mode 15%).

A retrospective review of the pre- and post-operative AP pelvis radiographs of 50 randomly selected patients who underwent THR in 1998 was performed. The radiographs were taken using the uniform standard technique. The magnification of the post-op radiograph was calculated by measuring the femoral head size. This was compared to the magnification of the pre-op radiographs using the ratio of the inter-teardrop distance. The post-operative radiographs were templated using a 15% template and compared to the size of prosthesis inserted.

The mean radiograph magnification was 22.5% (range 10.7 to 32.6%), with the majority (74%) between 20–25%. The 15% template oversized the prosthesis in 68% of cases. A 10% template would have been inaccurate in 96% of our sample group.

In a standard AP pelvis radiograph, the only variable that affects magnification is the extent to which the patient’s soft tissues raise the bony structures away from the plate. This variation in magnification renders preoperative templating of the femur in THR unreliable. Accuracy could be improved by using templates with a magnification of 22.5%.