header advert
Results 1 - 50 of 55
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 81 - 81
23 Jun 2023
MacDonald SJ Alatassi R Somerville L Howard JL
Full Access

The Canadian Cardiovascular Society (CCS) recommends performing daily troponin testing on postoperative days 0 through 3 for noncardiac surgical patients to decrease the mortality rate due to myocardial injury. Indications for testing include:

->65 yo

-45-64 yo with significant cardiovascular disease

-a Revised Cardiac Risk Index score (RCRI) > 1

Troponin elevation > 30 ng/L is termed “myocardial injury after noncardiac surgery” (MINS).

The study objective was to determine the prognostic relevance of applying CCS recommendations.

669 patients undergoing THA were included in the study. Based on the CCS recommendation there were 4 patient Groups depending on whether or not they met the MINS screening protocol criteria and whether or not it was applied:

-A - met & applied (n=181)

-B - met & not applied (n=248)

-C – not met & applied (n=10)

-D – not met & not applied (n=230)

307 (45.8%) males and 363 (54.2%) females with an average age of 67.8 years were included. Group A- 24% incidence (43 patients) of troponin rise & 5% incidence (9 patients) of cardiac complications. Group B- 0.4% incidence (1 patient) of cardiac complications.

Groups A + B – representing all patients who should have had the MINS screening protocol applied according to the CCS recommendations − 10 (2.3%) patients developed cardiac complication and one (0.2%) patient death

MINS screening protocol group (A & C) LOS was 4.0 days compared to 1.4 days for those not screened (p-value: <0.001).

Applying the CCS MINS screening protocol to elective THA patients added no benefit in predicting/preventing postoperative cardiac events but was associated with a significant increase in LOS. Following current CCS recommendations without more specifications and clinical evidence is unwarranted.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 35 - 35
1 Oct 2018
MacDonald SJ Garach M Lanting B McCalden RW Vasarhelyi E Naudie D Howard J
Full Access

Introduction

The infection rate after total joint arthroplasty (TJA) has been shown to be 1–2% in multiple series and registry data. Irrigation, debridement, and polyethylene exchange (IDPE) is a common first line treatment in many cases of acute prosthetic joint infection (PJI). The reinfection rate in open IDPE procedures is variable with studies showing reinfection rates of 10–70% depending on various patient and microbial factors. Our pilot study aimed to determine if the bacterial load in infected total joints was sufficiently reduced by IDPE to allow for the use of post-debridement cultures as an independent marker of procedural success.

Methods

46 prosthetic joint infections underwent irrigation and debridement using 6L of normal saline and 3L of a normal saline and bacitracin mixture prior to the insertion of a new polyethylene liner. This protocol utilized a single equipment setup with all surgical members donning new gloves prior to polyethylene exchange. Between 3 and 5 intraoperative cultures were obtained both prior to and after debridement as per the surgeon's standard protocol. A two-tailed student's t-test was used to evaluate for any differences in the rate of positive culture between these two groups.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 42 - 42
1 Oct 2018
McCalden RW Clout A Naudie DD MacDonald SJ Somerville LE
Full Access

Purpose

The success of total knee replacement (TKR) surgery can be attributed to improvements in TKR design, instrumentation, and surgical technique. Over a decade ago oxidized zirconium (OxZr) femoral components were introduced as an alternative bearing surface to cobalt-chromium (CoCr), based on strong in-vitro evidence, to improve the longevity of TKR implants. Early reports have demonstrated the clinical success of this material however no long-term comparative studies have demonstrated the superiority of OxZr implants compared to a more traditional CoCr implant. This study aims to compare long-term survivorship and outcomes in OxZr and CoCr femoral components in a single total knee design.

Methods

We reviewed our institutional database to identify all patients whom underwent a TKA with a posterior stabilized OxZr femoral component with a minimum of 10 years of follow-up. These were then matched to patients whom underwent a TKA with the identical design posterior stabilized CoCr femoral component during the same time period by gender, age and BMI. All patients had their patella resurfaced. All patients were prospectively evaluated preoperatively and postoperatively at 6 weeks, 3 months, 12 months, 2 years and every 1 to 2 years thereafter. Prospectively collected clinical outcome measures included, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Short-Form 12 (SF-12) and Knee Society clinical rating scores (KSCRS). Charts and radiographs were reviewed to determine the revision rates and survivorship (both all cause and aseptic) at 10 years allowing comparison between the two cohorts. Paired analysis was performed to determine if differences existed in patient reported outcomes.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 26 - 26
1 Oct 2018
McCalden RW Ponnusamy K Vasarhelyi EM Somerville LE Howard JL MacDonald SJ Naudie DD Marsh JD
Full Access

Introduction

The purpose of this study is to estimate the cost-effectiveness of performing total hip arthroplasty (THA) versus nonoperative management (NM) in non-obese (BMI 18.5–24.9), overweight (25–29.9), obese (30–34.9), severely-obese (35–39.9), morbidly-obese (40–49.9), and super-obese (50+) patients.

Methods

We constructed a state-transition Markov model to compare the cost-utility of THA and NM in the six above-mentioned BMI groups over a 15-year time period. Model parameters for transition probability (i.e. risk of revision, re-revision, death), utility, and costs (inflation adjusted to 2017 US dollars) were estimated from the literature. Direct medical costs of managing hip arthritis were accounted in the model. Indirect societal costs were not included. A 3% annual discount rate was used for costs and utilities. The primary outcome was the incremental cost-effectiveness ratio (ICER) of THA versus NM. One-way and Monte Carlo probabilistic sensitivity analysis of the model parameters were performed to determine the robustness of the model.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 64 - 64
1 Oct 2018
MacDonald SJ Culliton SE Bryant D Hibbert K Chesworth BM
Full Access

Purpose

Patient expectations of total knee arthroplasty (TKA) can be managed through education. E-learning is the application of information technology to education. Providing information to patients at the place and time of their choosing, e-learning has the potential to broaden the reach of existing services for patients. This study evaluated whether an e-learning tool could affect whether patients felt their expectations were met and whether they were satisfied with surgery one year following primary TKA.

Method

We recruited consecutive patients with osteoarthritis and randomized them to either standard patient education (n=207), or to our standard patient education plus a new e-learning tool (n=209). Preoperative measures were completed following the patients’ Pre-Admission clinic (PAC) visit and prior to accessing the e-learning tool. Postoperative patient reported outcome measures (PROMs) were completed at six weeks, three months and one year after TKA.

We used the Postoperative Expectation Questionnaire to measure the degree to which patient expectations had been met and the Patient Acceptable Symptom State (PASS) question to measure patient satisfaction at one year postoperative. We collected several PROMs for descriptive purposes including: new Knee Society Knee Scoring System (KSS); (Pre-Op and Post-Op versions), Knee injury and Osteoarthritis Outcome Score (KOOS), the Medical Outcomes Study 12-Item Short Form Health Survey, version 2 (SF-12), Hospital Anxiety and Depression Scale (HADS), Pain Catastrophizing Scale (PCS), University of California at Los Angeles (UCLA) Activity Score, and the Social Role Participation Questionnaire (SRPQ).


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 891 - 897
1 Jul 2018
Teeter MG Lanting BA Naudie DD McCalden RW Howard JL MacDonald SJ

Aims

The aim of this study was to determine whether there is a difference in the rate of wear between acetabular components positioned within and outside the ‘safe zones’ of anteversion and inclination angle.

Patients and Methods

We reviewed 100 hips in 94 patients who had undergone primary total hip arthroplasty (THA) at least ten years previously. Patients all had the same type of acetabular component with a bearing couple which consisted of a 28 mm cobalt-chromium head on a highly crosslinked polyethylene (HXLPE) liner. A supine radiostereometric analysis (RSA) examination was carried out which acquired anteroposterior (AP) and lateral paired images. Acetabular component anteversion and inclination angles were measured as well as total femoral head penetration, which was divided by the length of implantation to determine the rate of polyethylene wear.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 170 - 175
1 Feb 2018
Lam Tin Cheung K Lanting BA McCalden RW Yuan X MacDonald SJ Naudie DD Teeter MG

Aims

The aim of this study was to evaluate the long-term inducible displacement of cemented tibial components ten years after total knee arthroplasty (TKA).

Patients and Methods

A total of 15 patients from a previously reported prospective trial of fixation using radiostereometric analysis (RSA) were examined at a mean of 11 years (10 to 11) postoperatively. Longitudinal supine RSA examinations were acquired at one week, one year, and two years postoperatively and at final follow-up. Weight-bearing RSA examinations were also undertaken with the operated lower limb in neutral and in maximum internal rotation positions. Maximum total point motion (MTPM) was calculated for the longitudinal and inducible displacement examinations (supine versus standing, standing versus internal rotation, and supine versus standing with internal rotation).


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 616 - 621
1 May 2016
Teeter MG Thoren J Yuan X McCalden RW MacDonald SJ Lanting BA Naudie DDR

Aims

The purpose of the present study was to examine the long-term fixation of a cemented fixed-bearing polished titanium tibial baseplate (Genesis ll).

Patients and Methods

Patients enrolled in a previous two-year prospective trial (n = 35) were recalled at ten years. Available patients (n = 15) underwent radiostereometric analysis (RSA) imaging in a supine position using a conventional RSA protocol. Migration of the tibial component in all planes was compared between initial and ten-year follow-up. Outcome scores including the Knee Society Score, Western Ontario and McMaster Universities Arthritis Index, 12-item Short Form Health Survey, Forgotten Joint Score, and University of California, Los Angeles Activity Score were recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 28 - 32
1 Jan 2016
Hanna SA Somerville L McCalden RW Naudie DD MacDonald SJ

Aims

The purpose of this study was to compare the long-term results of primary total hip arthroplasty (THA) in young patients using either a conventional (CPE) or a highly cross-linked (HXLPE) polyethylene liner in terms of functional outcome, incidence of osteolysis, radiological wear and rate of revision.

Methods

We included all patients between the ages of 45 and 65 years who, between January 2000 and December 2001, had undergone a primary THA for osteoarthritis at our hospital using a CPE or HXLPE acetabular liner and a 28 mm cobalt-chrome femoral head.

From a total of 160 patients, 158 (177 hips) were available for review (CPE 89; XLPE 88). The mean age, body mass index (BMI) and follow-up in each group were: CPE: 56.8 years (46 to 65); 30.7 kg/m2 (19 to 58); 13.2 years (2.1 to 14.7) and HXLPE: 55.6 years (45 to 65); BMI: 30 kg/m2 (18 to 51); 13.1 years (5.7 to 14.4).


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 3 - 5
1 Jan 2016
Perry KI MacDonald SJ

Obesity is a worldwide epidemic that has both economic and health implications of enormous consequence. The obese patients tend to have earlier symptoms related to osteoarthritis, more peri-operative medical problems, higher rates of infection and more technical difficulties intra-operatively following hip and knee arthroplasty. Nevertheless, these patients have good long-term clinical outcomes and implant survival rates and are often some of the most satisfied patients after joint arthroplasty. Therefore, obese patients should not be denied surgery based on their weight alone.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):3–5.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1640 - 1644
1 Dec 2015
Dzaja I Vasarhelyi EM Lanting BA Naudie DD Howard JL Somerville L McCalden RW MacDonald SJ

The purpose of this study was to compare clinical outcomes of total knee arthroplasty (TKA) after manipulation under anaesthesia (MUA) for post-operative stiffness with a matched cohort of TKA patients who did not requre MUA.

In total 72 patients (mean age 59.8 years, 42 to 83) who underwent MUA following TKA were identified from our prospective database and compared with a matched cohort of patients who had undergone TKA without subsequent MUA. Patients were evaluated for range of movement (ROM) and clinical outcome scores (Western Ontario and McMaster Universities Arthritis Index, Short-Form Health Survey, and Knee Society Clinical Rating System) at a mean follow-up of 36.4 months (12 to 120). MUA took place at a mean of nine weeks (5 to 18) after TKA. In patients who required MUA, mean flexion deformity improved from 10° (0° to 25°) to 4.4° (0° to 15°) (p < 0.001), and mean range of flexion improved from 79.8° (65° to 95°) to 116° (80° to 130°) (p < 0.001). There were no statistically significant differences in ROM or functional outcome scores at three months, one year, or two years between those who required MUA and those who did not. There were no complications associated with manipulation.

At most recent follow-up, patients requiring MUA achieved equivalent ROM and clinical outcome scores when compared with a matched control group. While other studies have focused on ROM after manipulation, the current study adds to current literature by supplementing this with functional outcome scores.

Cite this article: Bone Joint J 2015;97-B:1640–4.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 70 - 73
1 Nov 2013
Lanting BA MacDonald SJ

Total hip replacement (THR) is a very common procedure undertaken in up to 285 000 Americans each year. Patient satisfaction with THR is very high, with improvements in general health, quality of life, and function while at the same time very cost effective. Although the majority of patients have a high degree of satisfaction with their THR, 27% experience some discomfort, and up to 6% experience severe chronic pain. Although it can be difficult to diagnose the cause of the pain in these patients, this clinical issue should be approached systematically and thoroughly. A detailed history and clinical examination can often provide the correct diagnosis and guide the appropriate selection of investigations, which will then serve to confirm the clinical diagnosis made.

Cite this article: Bone Joint J 2013;95-B, Supple A:70–3.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1217 - 1221
1 Sep 2013
Corten K Struelens B Evans B Graham E Bourne RB MacDonald SJ

A soft-tissue defect over an infected total knee replacement (TKR) presents a difficult technical problem that can be treated with a gastrocnemius flap, which is rotated over the defect during the first-stage of a revision procedure. This facilitates wound healing and the safe introduction of a prosthesis at the second stage. We describe the outcome at a mean follow-up of 4.5 years (1 to 10) in 24 patients with an infected TKR who underwent this procedure. A total of 22 (92%) eventually obtained a satisfactory result. The mean Knee Society score improved from 53 pre-operatively to 103 at the latest follow-up (p < 0.001). The mean Western Ontario and McMaster Universities osteoarthritis index and Short-Form 12 score also improved significantly (p < 0.001).

This form of treatment can be used reliably and safely to treat many of these complex cases where control of infection, retention of the components and acceptable functional recovery are the primary goals.

Cite this article: Bone Joint J 2013;95-B:1217–21.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 758 - 763
1 Jun 2013
Rajgopal R Martin R Howard JL Somerville L MacDonald SJ Bourne R

The purpose of this study was to examine the complications and outcomes of total hip replacement (THR) in super-obese patients (body mass index (BMI) > 50 kg/m2) compared with class I obese (BMI 30 to 34.9 kg/m2) and normal-weight patients (BMI 18.5 to 24.9 kg/m2), as defined by the World Health Organization.

A total of 39 THRs were performed in 30 super-obese patients with a mean age of 53 years (31 to 72), who were followed for a mean of 4.2 years (2.0 to 11.7). This group was matched with two cohorts of normal-weight and class I obese patients, each comprising 39 THRs in 39 patients. Statistical analysis was performed to determine differences among these groups with respect to complications and satisfaction based on the Western Ontario and McMaster Universities (WOMAC) osteoarthritis index, the Harris hip score (HHS) and the Short-Form (SF)-12 questionnaire.

Super-obese patients experienced significantly longer hospital stays and higher rates of major complications and readmissions than normal-weight and class I obese patients. Although super-obese patients demonstrated reduced pre-operative and post-operative satisfaction scores, there was no significant difference in improvement, or change in the score, with respect to HHS or the WOMAC osteoarthritis index.

Super-obese patients obtain similar satisfaction outcomes as class I obese and normal-weight patients with respect to improvement in their scores. However, they experience a significant increase in length of hospital stay and major complication and readmission rates.

Cite this article: Bone Joint J 2013;95-B:758–63.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 100 - 102
1 Nov 2012
Vasarhelyi EM MacDonald SJ

Obesity is an epidemic across both the developed and developing nations that is possibly the most important current public health factor affecting the morbidity and mortality of the global population. Obese patients have the potential to pose several challenges for arthroplasty surgeons from the standpoint of the influence obesity has on osteoarthritic symptoms, their peri-operative medical management, the increased intra-operative technical demands on the surgeon, the intra- and post-operative complications, the long term outcomes of total hip and knee arthroplasty. Also, there is no consensus on the role the arthroplasty surgeon should have in facilitating weight loss for these patients, nor whether obesity should affect the access to arthroplasty procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 157 - 166
1 Nov 2012
Rosenberg AG Berend ME Berry DJ Della Valle CJ MacDonald SJ Minas T

This conversation represents an attempt by several arthroplasty surgeons to critique several abstracts presented over the last year as well as to use them as a jumping off point for trying to figure out where they fit in into our current understanding of multiple issues in modern hip and knee arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 28 - 28
1 Sep 2012
Whitehead D MacDonald SJ Bourne RB McCalden RW
Full Access

Purpose

The mobile-bearing total knee arthroplasty was designed to increase the contact area with the polyethylene bearing, through the functional range of motion, and subsequently decrease the wear rate previously seen in fixed-bearing implants. In the literature there is no clear clinical advantage between the different designs in the short to mid-term follow-up.

The purpose of this study was to compare the results between a cruciate retaining mobile-bearing design (SAL II, Sulzer) and two cruciate retaining fixed-bearing designs (AMK, Depuy, and the Genesis II, Smith and Nephew).

Method

Ninety patients were randomised to receive either the mobile-bearing or one of the two fixed-bearing designs between 2000 and 2002. Patients were evaluated preoperatively and postoperatively using the WOMAC and the SF-12, both of which are validated scores.

One patient was withdrawn due to dementia before three months and eleven patients died. Two patients were revised due to infection (both had received the SAL II). One patient was revised for aseptic loosening and one patient was revised for pain (both had received the Genesis II).

Of the 74 patients (77 knees) that remain, they were last seen on average 6.4 years (2–10) after their surgery. Their average age at the surgery was 69.2 years (52–81).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 29 - 29
1 Sep 2012
MacDonald SJ Somerville L Naudie DD McAuley J McCalden R Bourne RB
Full Access

Purpose

Unicompartmental versus total knee arthroplasty has been a debated topic for decades. The purpose of this study was to compare the survivorship and clinical outcomes of a large primary total knee arthroplasty versus unicompartmental knee arthroplasty cohort.

Method

A consecutive series of 6352 TKAs and 296 UKAs with a minimum of one year follow-up were evaluated. Pre-operative scores, latest scores, and change in clinical outcome scores (KSCRS, SF12, WOMAC) were compared and tested for significance using the students t-test.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 115 - 115
1 Sep 2012
MacDonald SJ Somerville L Howard J Naudie DD McAuley J McCalden R Bourne R
Full Access

Purpose

The pros and cons of general anesthesia versus spinal anesthesia in total hip arthroplasty has been a long debated topic. The purpose of this study was to compare the surgical times, blood loss and transfusion requirements between anesthetic types in patients undergoing primary total hip arthroplasty.

Method

A consecutive series of 1600 THA procedures with complete preoperative and postoperative data were evaluated. Twenty eight percent of procedures were performed with a general anesthetic (GA), 67% with a spinal anesthetic (SP) and 5% with a combination of the two. Outcomes were compared and tested for significance using the Independent Samples Kruskal Wallis or Pearson Chi-Square analysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 24 - 24
1 Sep 2012
McCalden R Martin R Somerville L Bourne RB MacDonald SJ
Full Access

Purpose

The purpose of this study was to compare the outcomes and complications of normal weight, class one obese (BMI=30-34.9 kg/m2) and superobese (BMI≥50 kg/m2) primary total knee replacement (TKR) patients.

Method

Between January 1995 and December 2005, 4104 primary TKR were performed in our centre. Patients were stratified for their obesity level according the World Health Organisation (WHO) and current surgical literature classification. Sixty-seven superobese patients (group one) were identified. They were matched with normal weight (group two) and class one obese (group three) primary TKR patients for sex, age, side, preoperative diagnosis, implants used, time since surgery and preoperative SF-12 mental component summary score (MCS). Patient clinical outcomes (WOMAC, SF-12 and Knee Society scores), radiographs, complications, readmissions, and revisions rates were compared for normal BMI, class one obese and superobese patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 27 - 27
1 Sep 2012
McAuley JP Lyons M Howard J McCalden R Naudie DD Bourne RB MacDonald SJ
Full Access

Purpose

The patella provides a mechanical advantage to the knee extensor mechanism. Patellectomy, performed for trauma or patellofemoral arthrosis, does not preclude the development of tibiofemoral arthrosis. Total knee arthroplasty is the mainstay of treatment for tibiofemoral arthrosis. The purpose of this study was to evaluate the outcomes of total knee arthoplasty in patients who previously underwent patellectomy.

Method

A retrospective analysis was completed on a prospectively collected database to identify all patients who underwent total knee arthroplasty following a previous patellectomy. Sixty-one total knee arthroplasties in 57 patients were identified. Patient demographics as well as functional outcome scores, including WOMAC and Knee Society Scores, were evaluated.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 559 - 559
1 Nov 2011
McCalden RW MacDonald SJ Charron KD Bourne RB Naudie DD
Full Access

Purpose: The range of motion after TKA depends on many patient, surgical technique, and implant factors. Recently, high-flexion designs have been introduced as a means of ensuring or gaining flexion after TKA. We therefore evaluated factors affecting postoperative flexion to determine whether implant design influences long-term flexion.

Method: We prospectively collected data on patients receiving a primary Genesis II total knee replacement with a minimum of 1-year followup (mean, 5.4 years; range, 1–13 years). We recorded pre – and postoperative outcome measures, patient demographics, and implant design (cruciate retaining [CR, n = 160], posterior stabilized [PS, n = 1177], high-flex posterior stabilized [HF-PS, n = 197]).

Results: Backward stepwise linear regression modeling revealed the following factors that significantly affected postoperative flexion: preoperative flexion, gender, body mass index, and implant design. Independent of gender, body mass index, and preoperative flexion, patients who received a HF-PS and PS design implant resulted in 8° and 5° more flexion, respectively, than those who received a CR implant. Based on analysis examining pre-operative flexion categories, patients with low flexion preoperatively (< 100°) were more likely to gain flexion, whereas those with high flexion preoperatively (> 120°) were most likely to maintain or lose flexion postoperatively. Controlling for implant design, patients with high flexion preoperatively (> 120°) were more likely to gain flexion with the HF-PS design implant (HF-PS = 32.0%; PS = 15.1%; CR = 4.5%).

Conclusion: In summary, our data demonstrate postoperative range of motion after TKA is related to several factors, confirming the important role of the patient’s preoperative range of motion. In addition, our review suggests knee design and, in particular, the use of a so called “high-flexion” PS polyethylene design may be advantageous in maintaining or improving flexion postoperatively, especially in those patients with good pre-operative range of motion.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 567 - 568
1 Nov 2011
McCalden RW Naudie DD Bourne RB MacDonald SJ Holdsworth DW Yuan X Charron KD
Full Access

Purpose: Efforts to decrease polyethylene wear have lead to advances in polyethylene and counter-face technology for total hip replacement. In particular, the use of highly cross-linked polyethylene (XLPE) and more recently, oxidized zirconium (Oxinium) heads, have demonstrated significant in-vitro improvements in THR wear. This study reports on the early clinical performance and wear (measured with RSA) of an randomized controlled trial (RCT) comparing Oxinium and CoCr heads on XLPE and conventional polyethylene (CPE).

Method: Forty patients were enrolled in a RCT and stratified to receive either an Oxinium (Ox) or CoCr head against either XLPE or CPE (ie 10 patients in each group). All patients had otherwise identical THRs and had tantalum beads inserted in the pelvis and polyethylene for wear analysis. There were no significant differences between groups with respect to patient demographics and the average age was 68 years (range 57–76) at index procedure. RSA wear analysis was performed immediately post-op, at six weeks, three and six months and then at one and two years. All patients are a minimum of four years post-op (average 4.6, range 4 – 5.8). Patients were followed prospectively using validated clinical outcome scores (WOMAC, SF-12, Harris Hip scores) and radiographs.

Results: All health-related outcomes were significantly improved from pre-operative with a mean Harris Hip score and WOMAC at last follow-up of 90.9 and 80.2, respectively. Total 3D femoral head penetration at two years for each group were the following: CoCrXLPE (0.068±0.029mm); OxXLPE (0.115±0.038mm); CoCrCPE (0.187±0.079mm); and OxCPE (0.242±0.088mm). Thus, OxCPE was significantly higher than OxXLPE and CoCrXLPE but not CoCrCPE (p=0.001, p> 0.0001 and p=0.094, respectively). In other words, head penetration was higher with CPE compared to XLPE but there was no significant difference between Ox and CoCr heads. Similarily, regardless of head type (ie combining similar poly types), there was a significant difference in 3D head penetration at two years between CPE and XLPE ( CPE 0.213±0.086; XLPE 0.093±0.041, p> 0.0001).

Conclusion: The early results of this RCT, using RSA as the wear analysis tool, indicate a significant improvement in wear with XLPE compared to CPE. However, it failed to show a clear advantage to the use of Oxinium over CoCr against either polyethylene. Longer follow-up is required to determine steady-state wear rates (after bedding-in) and allow comparison between bearing groups.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 586 - 586
1 Nov 2011
McCalden RW Bourne RB Charron KD MacDonald SJ Rorabeck CH
Full Access

Purpose: The Genesis II total knee arthroplasty system was introduced in 1996 as the next evolution in TKR design characterized by “built-in” femoral external rotation and improved trochlear design to optimize patellar tracking and femoral/tibial kinematics, as well as a polished tibial base plate and ethylene-oxide sterilized polyethylene to minimize wear. The purpose of this prospective study was to evaluate the long-term (minimum 10 year) clinical and radiographic results and survivorship of this novel TKA implant system.

Method: Between 1996 and 1999, 478 Genesis II Primary TKRs were implanted and followed prospectively in 414 patients (mean follow-up 11.25±1.11 years). Diagnosis at index surgery included: 94% osteoarthritis, 5% inflammatory arthritis, 1% other diagnoses. Average age at index TKR was 68 years (range 38 to 93 years). There were 149 posterior cruciate retaining (31%) and 329 cruciate sacrificing (69%) knees implanted. Patella resurfacing was performed on 89% (432) of the cases. Sixty-seven deaths occurred prior to 10 years follow-up. Patients were followed prospectively using validated clinical outcome scores (WOMAC, SF-12, Knee Society scores) and radiographs. Kaplan-Meier survival analysis was performed.

Results: All health-related outcomes were significantly improved from preoperative with a mean Knee Society Score and WOMAC at last follow-up of 162 and 69, respectively. To date, 16 revision procedures have been performed. Revisions for infection included six two-stage revisions and two cases of irrigation & debridement with polyethylene exchange. In addition, there were three re-operations for stiffness and one for patellar instability. To date, there have been only two revisions for aseptic loosening and/or osteolysis. Excluding revisions for infection, the Kaplan-Meier survivorship analysis of the total knee system was 98.9±0.5% at five years and 98.2±0.6% at 10 years.

Conclusion: The Genesis II total knee arthroplasty system, characterized by “built-in” femoral external rotation, improved trochlear design, a polished tibial base plate and ethylene-oxide sterilized polyethylene, has demonstrated excellent clinical & radiographic results and long-term survivorship (98% at 10 years) at our institution.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 568 - 568
1 Nov 2011
MacDonald SJ Engh CA Naudie DD Engh CA McCalden RW Thompson AE Sritulanondha S
Full Access

Purpose: A ceramic head coupled to a metal liner is a proposed new alternate bearing in THA. The authors participated in an FDA approved multicentre prospective, randomized, blinded clinical trial comparing ceramic-on-metal (CoM) to metal-on-metal (MoM) in patients receiving a THA.

Method: 390 patients received the same acetabular component and metal insert. 194 patients received a delta ceramic head (CoM) and 196 received a metal head (MoM). Metal ions were evaluated in 72 patients (36-CoM, 36-MoM). Harris Hip scores, radiographs, and metal ion levels (cobalt, chromium and titanium in serum, erythrocytes and urine) were evaluated pre-operatively and at three, 12 and 24 months.

Results: No patients were lost to follow-up. There were no differences between groups’ baseline demographics and clinical scores. At two years there were no differences in Harris Hip scores, radiographs, adverse events or postoperative complications. Both groups had overall very low median metal ion profiles with no statistically significant differences. 24 month MoM vs CoM; Serum cobalt ( g/L), mean: 1.2(+/−0.5) vs 1.1(+/−0.3), median: 0.66(range: 0.2–5.6) vs 1.0 (range: 0.3–2.7); Serum chromium ( g/L), mean: 1.1(+/−0.5) vs 1.4(+/−0.4), median: 0.86(range: 0.3–6.9) vs 1.2(range: 0.3–4.9). Urine cobalt and urine chromium ( g/day) demonstrated similar trends to serum ion levels.

Conclusion: While CoM is a new bearing surface in North America and not currently FDA or HPB approved, it has been in clinical use globally since 2006. Results of this non-inferiority RCT demonstrated no clinical outcome, metal ion, radiographic or adverse event differences between CoM and MoM cohorts.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 558 - 559
1 Nov 2011
Teeter MG Naudie DD McErlain DD Brandt J Yuan X MacDonald SJ Holdsworth DW
Full Access

Purpose: This study develops and validates a technique to quantify polyethylene wear in tibial inserts using micro-computed tomography (micro-CT), a nondestructive high resolution imaging technique that provides detailed images of surface geometry in addition to volumetric measurements.

Method: Six unworn and six wear-simulated Anatomic Modular Knee (DePuy Inc, Warsaw, IN) tibial inserts were evaluated. Each insert was scanned three times using micro-CT at a resolution of 50 μm. The insert surface was reconstructed for each scan through automatic segmentation and the insert volume was calculated. Gravimetric analysis was also performed for all inserts, and the micro-CT and gravimetric volumes were compared to determine accuracy. The utility of surface deviation maps derived from micro-CT was demonstrated by co-registering a worn and unworn insert. 3D deviations were measured continuously across the entire insert surface, including the articular and backside surfaces.

Results: The mean percent volume difference between the micro-CT and gravimetric techniques was 0.04% for the unworn inserts and 0.03% for the worn inserts. No significant difference was found between the micro-CT and gravimetric volumes for the unworn or worn inserts (P = 0.237 and P = 0.135, respectively). The mean coefficient of variation for volume between scans was 0.07% for both unworn and worn inserts. The map of surface deviations between the worn and unworn insert revealed focal deviations exceeding 750 μm due to wear.

Conclusion: Micro-CT provides precise and accurate volumetric measurements of polyethylene tibial inserts. Quantifiable 3D articular and backside surface deviation maps can be created from the detailed geometry provided by the technique. Compared to coordinate mapping, micro-CT provides 10 times greater surface sampling resolution (50 μm vs 500 μm) across the entire insert surface. Micro-CT is a useful analysis tool for wear simulator and retrieval studies of the polyethylene components used in total knee replacement.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 565 - 565
1 Nov 2011
McAuley JP Charron KD Rorabeck CH Bourne RB MacDonald SJ
Full Access

Purpose: The purpose of this study was to investigate the mid to long term (minimum 10 years follow-up) survivorship of the AMK total knee arthroplasty (TKA), as well as determine the effect of implant fixation on outcome.

Method: Between 1988 and 2000, 1074 AMK primary total knee arthroplasties were preformed on 843 patients. All diagnosis included, the distribution was 90% osteoarthritis (971), 7% inflammatory arthritis (76) and 3% other diagnoses (27). Average time from surgery was 15 years (range 10–21 years). Average age at primary procedure was 68 years (range 22–99). Fifty-six percent were female (599) and 44% male (475). Preoperative alignment consisted of 56% varus (601) and 17% valgus (182). Ninety percent (968) had patella resurfacing performed, 62% (661) received cemented TKA fixation, on 32% hybrid fixation (cemented femoral component, cementless tibial tray) was performed and 6% (66) had cementless fixation. Two hundred thirty-seven cases were deceased before 20 years follow-up (22%).

Results: At 10 to 21 years follow-up, 129 revisions were performed (12%). The most common reasons for revision were polyethylene wear, particle induced osteolysis, instability and pain (43% of revisions). Implant fixation significantly influenced the rate of revision with cemented fixation having a 6.7% rate of revision (44/661), hybrid fixation a 14% revision rate (47/336) and cementless a 36.4% revision rate (24/66). Excluding infections (11 cases), overall Kaplan-Meier survivorship at five, 10 and 15 years was 96.4%, 91.9% and 85.8%, respectively. At 20 years the predicted Kaplan-Meier survivorship was estimated at 83.5% (no revisions beyond 17.5 years). Cemented fixation was associated with significantly better survivorship than hybrid and cementless fixation (p< 0.0001). At 5, 10 and 15 years cemented AMK TKA survivorship was 97.5%, 94.9% and 91.9% respectively (no revision performed beyond 13.5 years). For hybrid fixation the survival at 5, 10 and 15 years was 97.8%, 92.2% and 85.1% respectively. Cementless AMK THA had a Kaplan-Meier survivor-ship of 88.9%, 78.2% and 57.4% at 5, 10 and 15 years respectively.

Conclusion: Cemented fixation had superior outcomes compared to cementless and hybrid fixation with the most common reasons for revision being polyethylene wear and osteolysis. To our knowledge this the first medium to long term follow-up of the AMK TKA and it demonstrates that method of fixation had a major influence on revision rates and survivorship.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 587 - 587
1 Nov 2011
McCabe M MacDonald SJ McCalden RW Bourne RB Naudie DD
Full Access

Purpose: Total knee arthroplasty (TKA) is a proven intervention in the management of end-stage knee arthritis. However, the demands of younger, more active patients may result in increased rates of wear and aseptic loosening. The purpose of this study was to assess the long-term outcome of a large cohort of young patients, and to assess if the outcomes of cemented implants differed from non-cemented implants.

Method: Between 1984 and 2003, 350 TKAs were performed in 283 patients who were under 55 years old. Patients were followed a minimum of 5 years. Mean age at time of surgery was 49.0±5.5 years; 64% of patients were female. Primary knee pathologies included degenerative and post-traumatic arthritis (271), inflammatory arthritis (62), and others (17). Multiple implant designs were used; 296 knees were cemented and 54 were non-cemented. The Knee Society Clinical Rating Score (KSCRS) at latest follow-up was calculated. The Kaplan-Meier survivorship was calculated using an endpoint of revision total knee arthroplasty.

Results: Mean follow-up was 8.7±3.4 years. Seventeen knees were revised at a mean of 7.1±4.4 years after the index procedure. Fifteen patients (twenty-five knees) died. Fifty-one patients (sixty-two knees) were lost to follow-up. Sixty patients (sixty-seven knees) had incomplete KSCRS forms. Average function and knee domains of the KSCRS were 70.0±26.7 and 87.3±16.2 respectively. The Kaplan-Meier survival at five, ten, and fifteen years was 0.965±0.011, 0.941±0.015, and 0.933±0.017. The rate of revision was 5.9%. There was no statistically significantly difference observed between the outcomes of cemented and non-cemented implants, male and female patients, or inflammatory versus non-inflammatory arthritis.

Conclusion: This study demonstrates that total knee replacement in younger patients can demonstrate excellent survival rates free of revision. There does not appear to be an obvious survival advantage of cementless designs, or difference in outcomes based on sex of the patient or primary diagnosis of inflammatory or non-inflammatory arthritis.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 587 - 587
1 Nov 2011
Ariaretnam SK Wallace RB Bourne RB MacDonald SJ McCalden RW Naudie DD Charron KD
Full Access

Purpose: Approximately, 10% of two-stage TKA revisions for deep sepsis become re-infected. The purpose of this study was to determine the success in terms of sepsis eradication and factors associated with failure of repeat two-stage revision TKA.

Method: Between 1991 and 2006, 129 two-stage revision TKRs for deep sepsis were performed. Ten cases which became re-infected were identified. These unfortunate patients, representing 8% of all the two-stage TKA revisions performed during this time period, are the focus of this study. Their progress and treatment interventions were followed for the purposes of this study.

Results: Ten patients were identified with a two-stage revision TKA which became re-infected. Mean patient age was 72 with 40 % being female. Following recurrent sepsis all patients went on to require more than one further two-stage revision (mean 3.67 further revision surgeries). Infection was only successfully eradicated in 28.7% of cases, the remaining require chronic suppressive therapy or have ongoing active infection. Two patients went on to have an arthrodesis (both remain on suppressive anti-biotics) and one patient had trans-femoral amputation. Staph Aureus and Coagulase neg Staph accounted for 80% of primary infective organisms with only one primary infection with methicillin resistant staph aureus (MRSA). Cultures at subsequent revisions were the same organism in 67% cases. Additional organism cultured included Pseudomonas and Propionibacterium. These patients had an increased incidence of multiple medical co-morbidities including Type-2 Diabetes Mellitus and Rheumatoid Arthritis.

Conclusion: Patients with recurrent sepsis after a two-stage revision for infection in TKR all required multiple further surgeries. Eradication of infection was only achieved in 28.7% cases. Risk factors for recurrent sepsis include Rheumatoid Arthritis and Type-2 Diabetes Mellitus.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 566 - 566
1 Nov 2011
Wallace R Bourne RB McCalden RW MacDonald SJ Charron KD
Full Access

Purpose: There is no consensus whether the posterior cruciate ligament (PCL)should be preserved (CR) or sacrificed (CS) during primary total knee replacement (TKR). The purpose of this study was to compare the greater than 10 year survivorship and health related outcomes of CR and CS TKRs using a single implant system.

Method: Between 1996 and 2000, 478 Genesis II Primary TKRs were inserted in 414 patients. Excluding those with a primary diagnosis other than osteoarthritis, body mass index greater then 40, history of prior patellectomy, fusion or osteotomy, 358 cases in 310 patients were included. 134 (37%) had a PCL preserving (CR) and 224 (63%) had a PCL sacrificing implant (CS). The two patient cohorts were compared for Kaplan-Meier survivorship, health-related outcomes (Knee Society scores, WOMAC, SF-12), range of motion (ROM) and radiographic loosening or wear.

Results: Mean follow-up was 11.87±1.04 years for CR and 10.96±0.87 years for CS (p=0.001). Four cases were revised for infection. No significant differences were noted between the CR and CS Genesis II cohorts at 10 year Kaplan-Meier survivorship excluding infections (CR 0.984±0.011, CS 0.986±0.008, p=0.30). Overall revisions were two for CR (1.5%, no infections) and seven for CS (1.7%, four for infection; 1.3% excluding infections). Revision rates were not significantly different between groups including or excluding infections (p=0.493 and p=1.00 respectively). CS had significantly greater postoperative ROM than CR (CS=114.20±13.60, CR=111.35±12.38, p=0.024). At 10 years, no differences were observed in satisfaction, health-related outcomes or radiographic wear/loosening. Crepitus was reported more frequently in CS design.

Conclusion: Most studies comparing PCL sacrificing (CS) versus retaining (CR) TKRs are short term. In this large, long term, single implant CR versus CS study, no differences were found in Kaplan-Meier survivorship, health-related outcomes or patient satisfaction. The CS design had more range of motion, but also a higher incidence of peripatellar crepitus than the CR design. We conclude that both CR and CS TKR designs can yield excellent long term clinical outcomes.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 566 - 566
1 Nov 2011
O’Connor PA Bourne RB MacDonald SJ McCalden RW Rorabeck CH Charron KD
Full Access

Purpose: High contact stresses and wear after total knee replacement (TKR) has been a problem. Mobile bearing TKRs have been advocated as a means to increase load bearing area, reduce contact stresses and minimize wear. The purpose of this study was to compare two, large, consecutive cohorts of TKR patients with greater than 10 years follow-up, one with a fixed bearing and one with a mobile bearing design.

Method: One hundred and three SAL II mobile bearing TKR’s were compared to a gender, age, BMI and time from surgery matched fixed bearing Genesis II cohort of equal size. All surgeries were performed between September 1993 and December 2000 (average follow-up, 11.64±1.64 years). Inclusion criteria included patients with osteoarthritis of the knee. Exclusion criteria included revision arthroplasty, inflammatory arthritis, a prior osteotomy or a prior patellectomy. The > 10 year Kaplan-Meier survivorship, health-related outcomes (Knee Society scores, WOMAC and SF-12), radiographs and retrieved implants for the fixed and mobile bearing TKR cohorts were compared.

Results: Fixed bearing TKRs demonstrated better 10 year Kaplan-Meier survivorships for any re-operation, 1.000±0.000 compared to 0.969±0.018 for mobile bearings (Genesis II and SAL I/II respectively). Revision rates were significantly different between groups with fixed bearing having no revisions and mobile four revisions (3.9%). No cases were revised for sepsis. Mobile bearing revisions were for pain (1), patellar maltracking (1), polyethylene wear (1) and aseptic loosening (1). At 10 years, health-related outcomes were similar between the two cohorts. Fixed bearing TKRs demonstrated more range of motion (111.42±12.76 vs 107.19±14.74 degrees) although not significant (p=0.052). Wear was more frequently noted in mobile bearing TKRs on > 10 year radiographs.

Conclusion: In this comparison of two contemporary TKRs, the fixed bearing TKR outperformed the mobile bearing TKR.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 567 - 567
1 Nov 2011
McCalden RW Charron KD Yuan X Bourne RB Naudie DD MacDonald SJ Thompson AE
Full Access

Purpose: The purpose of this prospective blinded randomized control trial was to compare the stem migration of two cemented stem designs using radiostereometric analysis (RSA). This was essentially a safety study in which our hypothesis was that the newer design (CPCS, Smith and Nephew Inc) would demonstrate similar micro-motion to the well-established Exeter (Stryker) design.

Method: Thirty patients were consented and enrolled into a blinded RCT in which 15 patients received a dedicated RSA CPCS stem and 15 patients received a RSA Exeter stem. Both stems are collarless tapered polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS design. Outcome measures were compared (Hip Society Score, WOMAC, SF-12). RSA analysis was conducted immediately postoperatively, at 6 weeks, 3 months, 6 months, 1 year and 2 years.

Results: No difference was found in any of the outcome measures pre-operatively or postoperatively. At 2 years, stem subsidence for the CPCS stem was approximately half that seen for the Exeter stem (0.565±0.189mm and 0.981±0.209mm respectively, p< 0.0001). In contrast, posterior (internal) rotation of the CPCS was approximately twice that of the Exeter stem (1.496±1.215° and 0.716±0.818° respectively, p=0.221). Other migration patterns were no different between stems.

Conclusion: As expected with this stem design, both stems showed some axial and rotational migration within the cement mantle. The subtle differences in design may explain the differences in migration patterns. Our data suggests that the newer CPCS design should perform well over the long-term.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 576 - 576
1 Nov 2011
McCalden RW Bourne RB Charron KD MacDonald SJ Rorabeck CH
Full Access

Purpose: The Synergy femoral component was introduced in late 1996 as a second generation titanium proximally porous-coated tapered stem with dual offsets (standard & high) to help better restore femoral offset at THR. The purpose of this prospective study was to evaluate the long-term (minimum 10 year) clinical and radiographic results and survivorship of this second-generation femoral component at our institution.

Method: From December 1996 to December 1999, 256 cementless Synergy femoral components were inserted and followed prospectively in 254 patients requiring THR. 185 were standard offset stems(72.3%) while 71 stems (27.7%) were high offset. The average follow-up was 11.2 years (range 10.0 to 12.9 years). Average age at index THR was 58.9 years (range 19 to 86 years). Two hundred eight stems had standard porous coating while 48 had additional HA coating. Fifty-two cases were either lost to follow-up or had died prior to 10 years follow-up. Patients were followed prospectively using validated clinical outcome scores (WOMAC, SF-12, Harris Hip scores) and radiographs. Kaplan-Meier survival analysis was performed.

Results: All health-related outcomes were significantly improved from pre-operative with a mean Harris Hip score and WOMAC at last follow-up of 91.6 and 81.8, respectively. From the initial 256 femoral stems inserted, only 5 stems have been revised. Two stems have been revised for infection. To date, only one stem has been revised due to subsidence at nine months following surgery likely, as a result of a calcar fracture occurring at the index THR. Two stems were revised for peri-prosthetic fracture as a result of patient falls at six months and 9.8 years post-op. Radiographic review of remaining stems in-situ identified no cases of loosening with all stems showing evidence of osseous integration. The Kaplan-Meier survivorship analysis of the femoral component, with revision for aseptic loosening, was 99.2%±0.008 at five, 10 and 12 years.

Conclusion: The Synergy femoral component, a second generation titanium proximally porous-coated tapered stem design with dual offsets, has demonstrated excellent clinical & radiographic results and long-term survivorship (99% at 10 years) at our institution.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 273 - 274
1 Jul 2011
MacDonald SJ Engh CA Thompson AE Sritulanondha S Naudie D Engh CA
Full Access

Purpose: Metal-on-metal articulations are an increasingly popular choice as an alternate bearing surface in total hip arthroplasty (THA) and Resurfacing implants. One advantage of a metal-on-metal bearing is the use of larger diameter femoral heads with hip simulator data demonstrating reduced wear. We performed a prospective, multicentre, randomized, blinded clinical trial comparing 28mm to 36mm metal-on-metal bearings assessing multiple validated outcome measures and serum, erythrocyte and urine metal ions.

Method: Ninety-one patients were randomized to receive a metal-on-polyethylene (34), a 28mm metal-on-metal (25) or a 36mm metal-on-metal (32) insert. All patients received the same acetabular and femoral component. Patients were evaluated pre-operatively, at 6, 12 months and annually thereafter, including an evaluation of serum, erythrocyte and urine cobalt, chromium, and titanium, outcome measures (WOMAC, SF-12, Harris Hip Score) and radiographs.

Results: At a minimum two years follow-up there were no differences in WOMAC, SF-12, Harris Hip scores or radiographs. Patients receiving metal liners had significantly (p< 0.001) elevated metal ion measurements compared with the polyethylene control group, however there were no differences between the 28mm and 36mm metal-on-metal bearings (Median serum Co (mg/L): 0.14(poly), 0.77(28mm), 0.73(36mm). Median erythrocyte Co (mg/L): 0.11(poly), 0.42(28mm), 0.42(36mm). Median urine Co(mg/day): 0.44(poly), 4.55(28mm), 5.42(36mm)). (Median serum Cr(mg/L): 0.17(poly), 1.29(28mm), 0.91(36mm). Median erythrocyte Cr(mg/ L): 1.10(poly), 1.10(28mm), 1.20(36mm). Median urine Cr(mg/day): 0.27(poly), 1.92(28mm), 2.02(36mm)).

Conclusion: Both cobalt and chromium ion measurements were significantly elevated in the blood and urine of the patients randomized to receive the metal-on-metal bearings at all time intervals. There were no differences seen between the 28mm and 36mm metal-on-metal bearings, keeping all other variables identical. The larger diameter bearing therefore provides the potential clinical advantages of improved range of motion and stability, while providing a similar metal ion profile. While reduced wear is seen with larger diameter metal-on-metal bearings in-vitro, we could not demonstrate a reduction in blood or urine metal ion levels in-vivo.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 247 - 247
1 Jul 2011
Seslija P Yuan X Naudie D Peters TM Bourne RB MacDonald SJ Holdsworth DW
Full Access

Purpose: Accurate measurement of dynamic joint motion remains a clinical challenge. To address this problem, we have developed a low-dose clinical procedure using the Roentgen Single-plane Photogrammetric Analysis (RSPA) technique. A validation study was performed in a clinical setting, using a conventional digital flat-panel radiography system.

Method: To validate the technique, three experiments were performed: assessment of static accuracy, dynamic repeatability and measurement of effective dose. A knee joint phantom, imbedded with tantalum markers, was utilized for the experiments. Relative spatial positions of the markers were reconstructed using Radiostereometric Analysis (RSA). A digital flat-panel radiography system was used for image acquisition, and the three-dimensional pose of each segment was determined from single-plane projections by applying the RSPA technique. All images were processed using software developed in-house. To assess static accuracy, the phantom was mounted onto a three-axis translational stage and moved through a series of displacements ranging from 0 to 500 μm. Images of the phantom were acquired at each position. Accuracy was calculated by analyzing differences between reconstructed and applied displacements. To assess dynamic repeatability, the phantom was mounted on a six-axis robot, programmed to apply a flexion-extension movement to the joint. Multiple cine acquisitions of the moving phantom were acquired (30 fps, 4 ms exposure). Repeatability was calculated by analyzing the variation between motions reconstructed from repeated acquisitions. The effective dose of the procedure was measured using an ion-chamber dosimeter. The ion chamber was positioned between the phantom and x-ray source, facing the source. Entrance exposure was measured for multiple acquisitions, from which the effective dose was calculated.

Results: The accuracy determined from the static assessment was 25 μm and 450μm at the 95% confidence intervals for translations parallel and orthogonal to the image plane, respectively. Repeatability of the motion reconstructed from dynamic acquisitions was better than ± 200 μm for translations and ± 0.1 for rotations. The average effective dose for a 6 second dynamic acquisition was approximately 2μSv.

Conclusion: The proposed clinical procedure demonstrates both a high degree of accuracy and repeatability, and delivers a low effective dose.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 262 - 262
1 Jul 2011
MacDonald SJ Charron KD Naudie D McCalden RW Hospital U Bourne RB Rorabeck CH
Full Access

Purpose: The growing trend of morbidly obese (BMI 40+) patients requiring a total joint replacement is becoming major concern in total knee Arthroplasty (TKA). The purpose of this study was to investigate the affects that BMI may have on implant longevity and clinical patient outcome using historical patient data.

Method: A consecutive cohort of 3083 TKA’s in 2048 patients since 1995 (minimum 2 years follow-up) were evaluated. Pre-operative scores, latest scores, and change in clinical outcome scores (KSCRS, SF12, WOMAC) were analyzed using ANOVA and Kaplan-Meier (K-M) survivorship was determined.

Results: K-M cumulative survival at 10 years by BMI group was 0.951±0.033 for Normal and Underweight (< 25, n=277), 0.944±0.024 for Overweight (25–29.9, n=915), 0.882±0.032 for Obese (30–39.9, n=1460) and 0.843±0.076 for Morbidly Obese (40+, n=352). Cumulative revision rates were 1.8% for Normal and Underweight, 1.9% for Overweight, 2.9% for Obese and 2.8% for Morbidly Obese. All pre-operative clinical scores were significantly different between the Morbidly Obese and all other BMI groups (p< 0.05), with the non-morbidly obese having higher scores in all cases. Significant difference was found in the change in WOMAC domain scores and the KSCRS knee score (p< 0.05) between the morbidly obese group and all other BMI groups, with the morbidly obese having the greatest improvement in all domains.

Conclusion: The morbidly obese patient cohort (BMI > 40) undergoing TKA demonstrated the most significant improvement in clinical outcome scores; however also had the lowest cumulative 10 year survivorship. This risk/benefit information is important in pre-operative discussions with this challenging, and increasingly prevalent, patient population.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 253 - 253
1 Jul 2011
MacDonald SJ Barrack RL Rosenzweig S Guerin JF McCalden RW Bohm E Bourne RB Rorabeck CH
Full Access

Purpose: There are two broad-based categories of cementless femoral components performed during total hip arthroplasty: proximally coated versus fully porous coated. While both have enjoyed widespread clinical applications, there remains debate regarding differences in clinical outcome scores, relative incidence of thigh pain and the development of stress shielding. The purpose of this study was to investigate these variables in a multi-center prospective randomized blinded clinical trial.

Method: Between three centers 388 patients were enrolled in this clinical trial. 198 patients received a proximally coated tapered cementless femoral component (Synergy, Smith and Nephew, Memphis) and 190 patients received a fully porous coated cementless femoral component (Prodigy, Depuy, Warsaw). Patients were evaluated pre-operatively, at 3, 6, 12 months and annually thereafter, with multiple validated outcome measures including WOMAC, SF12, HSS, UCLA activity and thigh pain scores. A cohort of 72 patients underwent preoperative and postoperative DEXA scanning.

Results: 367 patients had a minimum of 2 years follow-up (average 6.4 years). There were no differences in age at surgery, BMI, or pre-operative clinical outcome scores (WOMAC, SF12, HSS, UCLA activity, thigh pain) between groups. There were no differences in any post-operative clinical outcome scores at any interval of follow-up. There were no differences in incidence of thigh pain between groups at any time. The only measurable difference between study groups was in bone mineral density evaluation. Bone density change in Gruen zone 7 was 23.7% with the Prodigy stem and 15.3% with the Synergy stem (p=0.011).

Conclusion: Both fully porous coated and proximally porous coated cementless stems performed well, with no clinical differences at a minimum of 2 years follow-up. Only bone mineral density evaluations could detect any differences between these femoral components designs.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 321 - 325
1 Mar 2011
McCalden RW Charron KD MacDonald SJ Bourne RB Naudie DD

We evaluated the outcome of primary total hip replacement (THR) in 3290 patients with the primary diagnosis of osteoarthritis at a minimum follow-up of two years. They were stratified into categories of body mass index (BMI) based on the World Health Organisation classification of obesity. Statistical analysis was carried out to determine if there was a difference in the post-operative Western Ontario and McMaster Universities osteoarthritis index, the Harris hip score and the Short-Form-12 outcome based on the BMI.

While the pre- and post-operative scores were lower for the group classified as morbidly obese, the overall change in outcome scores suggested an equal if not greater improvement compared with the non-morbidly obese patients. The overall survivorship and rate of complications were similar in the BMI groups although there was a slightly higher rate of revision for sepsis in the morbidly obese group.

Morbid obesity does not affect the post-operative outcome after THR, with the possible exception of a marginally increased rate of infection. Therefore withholding surgery based on the BMI is not justified.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 935 - 940
1 Jul 2010
McCalden RW Charron KD Yuan X Bourne RB Naudie DD MacDonald SJ

This was a safety study where the hypothesis was that the newer-design CPCS femoral stem would demonstrate similar early clinical results and micromovement to the well-established Exeter stem. Both are collarless, tapered, polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS stem. A total of 34 patients were enrolled in a single-blinded randomised controlled trial in which 17 patients received a dedicated radiostereometric CPCS stem and 17 a radiostereometric Exeter stem. No difference was found in any of the outcome measures pre-operatively or post-operatively between groups. At two years, the mean subsidence for the CPCS stem was nearly half that seen for the Exeter stem (0.77 mm (−0.943 to 1.77) and 1.25 mm (0.719 to 1.625), respectively; p = 0.032). In contrast, the mean internal rotation of the CPCS stem was approximately twice that of the Exeter (1.61° (−1.07° to 4.33°) and 0.59° (0.97° to 1.64°), respectively; p = 0.048). Other migration patterns were not significantly different between the stems. The subtle differences in designs may explain the different patterns of migration.

Comparable migration with the Exeter stem suggests that the CPCS design will perform well in the long term.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 16 - 16
1 Mar 2010
MacDonald SJ Charron K Bourne RB McCalden RW Naudie DD Rorabeck CH
Full Access

Purpose: The increasing trend of morbidly obese patients (BMI 40+) requiring joint replacement is becoming a growing concern in Total Hip Replacement (THR) surgery. The purpose of this study was to investigate the influence that BMI may have on implant longevity and clinical outcome using prospectively collected patient data.

Method: A consecutive cohort of 2864 THR’s in 2488 patients with osteoarthritis and a minimum 2 years follow-up were evaluated. Patients were divided into appropriate BMI categories; Normal and Underweight (BMI< 25, n=650), Overweight (BMI 25–29.9, n=1069), Obese (BMI 30–39.9, n=981), and Morbidly Obese (BMI 40+, n=164). Pre-operative, latest, and change in clinical outcome scores (HSS, SF12, WOMAC) were analyzed using ANOVA and Kaplan-Meier (K-M) survivorship was determined. Categorical variables such as gender and survival status were analyzed using chi-squared.

Results: Morbidly Obese patients requiring THR’s were significantly younger than all other BMI groups by 5.4±0.83 years (p< 0.0001). Gender was also significant to BMI grouping with more females being Morbidly Obese and Normal or Underweight (p< 0.0001). All pre-operative and latest HHS and WOMAC domain scores were lower for the Morbidly Obese, significantly in all preoperative score domains and latest HHS Function (p< 0.05). The change in clinical scores from pre-operative to latest was greatest in all domains for the Morbidly Obese group. K-M cumulative survival with implant revision as the endpoint at 10 years was not different between the BMI groups. Revision rates for infection for the Morbidly Obese, Obese, Overweight, and Normal were 1.3%, 0.65%, 0.3% and 0.69% respectively. Overall Revision rates for the Morbidly Obese, Obese, Overweight, and Normal were 6.7%, 5.4%, 6.9% and 5.7% respectively and were not found to be significant (p=0.496).

Conclusion: The Morbidly Obese cohort undergoing THR had significantly lower preoperative and lower postoperative clinical outcome scores than all other BMI groups but demonstrated the most significant improvement. No difference was found in the K-M survivorship although revisions and revisions for infection were not equal between the groups


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 35 - 35
1 Mar 2010
Whittaker JP McAuley JP Naudie D McCalden RW MacDonald SJ Bourne RB
Full Access

Purpose: The results of medial unicompartmental knee replacement have been reported as excellent over the intermediate term with both fixed and mobile bearing designs. However not all publications report equal success, with different outcomes also reported between mobile and fixed bearing designs. The purpose of this study was to compare the outcomes of mobile and fixed bearing medial unicompartmental arthroplasties.

Method: We evaluated the results of 230 consecutive medial unicompartmental knee arthroplasties (UKA) designs performed between 1989 and 2006 at a single academic centre (London Health Sciences Centre). Eighty mobile bearing UKA (63 patients, mean follow up3.2 years) and 160 fixed bearing UKA (117 patients, mean follow up 6.2 years) were reviewed. The mean age of the patients at the time of surgery was 66 years. Forty nine patients died at a mean of 12.7 years after the index arthroplasty. Patients were evaluated clinically using the Knee Society, WOMAC and SF12 outcome scores and radiographically using the Knee Society rating system.

Results: In the fixed bearing group 21 knees underwent revision at a mean of 6.9 years after the index procedure. In the mobile bearing group 7 knees underwent revision at a mean of 2.6 years. The mean Knee Society knee and function scores for the patients who had not had a revision improved in both groups, with the fixed bearing group mean function and Knee Society Scores improving from 53 and 48 points preoperatively to 80 and 93 points at the time of the most recent evaluation. In the mobile bearing group the mean function and Knee Society Scores improved from 55 and 44 points preoperatively to 85 and 91 points at the time of the most recent evaluation. The five year cumulative survival rates were 96% (SE +/− 0.18) and 89% (SE +/− 0.46) for the fixed and mobile bearing designs respectively, with ten year cumulative survival rates of 85% (SE +/− 0.35) in the fixed bearing group using an endpoint of revision to tricompartmental knee arthroplasty.

Conclusion: Both bearing designs of medial unicompartmental knee arthroplasty provided excellent pain relief and restoration of function in carefully selected patients and demonstrated durable implant survival over the midterm. In this study the fixed bearing designs demonstrated improved survivorship over the mobile bearing designs at 5 years. This may be related to the learning curve of the different bearing systems.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 13 - 14
1 Mar 2010
McCalden RW Marr JT Bourne RB MacDonald SJ
Full Access

Purpose: The purpose of this study is to compare the clinical results of a standard polyethylene tibial insert versus the high flex polyethylene tibial insert component designs of a posterior cruciate substituting total knee replacement.

Method: One-hundred patients were entered into a prospective, randomized clinical trial comparing standard polyethylene tibial inserts versus the high flex polyethylene tibial insert component designs of posterior cruciate substituting total knee replacement(Genesis II, Smith & Nephew, Memphis, TN). Patients were evaluated pre-operatively, at 3, 12 months and annually thereafter. Patient demographics, radiographs, and multiple outcome measures (WOMAC, SF-12 and the Knee Society Clinical Rating System) were evaluated.

Results: No patients were lost to follow-up. One patient died prior to the two year follow up. Ninety- nine patients were reviewed at an average follow-up of 2.7 years (range 2.3 – 3.1 years). There were no significant differences in any outcome measures or radiographic findings. There were no differences in KSCRS at two years (Standard − 170, High Flex −171). There were no differences in knee flexion at 2 years (Standard− 125°, High Flex − 126°).

Conclusion: In this prospective randomized clinical trial, no differences could be seen between standard polyethylene and a “Hi- Flex” polyethylene design at a minimum of 2 years follow-up. In particular, no improvement in knee flexion was observed. Long-term evaluation will be required to comment on differences in polyethylene wear and implant longevity.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 36 - 36
1 Mar 2010
Rajgopal V Bourne RB McCalden RW MacDonald SJ Rorabeck CH
Full Access

Purpose: The purpose of this study was to determine the clinical and radiographic outcomes at a minimum follow-up of ten years of patients who underwent a total knee arthroplasty with an inset patellar component. The incidence of anterior knee pain and the factors which may contribute to were also studied.

Method: Patients who had genesis I/II TKA with an inset patellar button with a minimum follow-up of 10 years were identified. 448 patients with 521 knees were identified. Patients were excluded if they were deceased, had incomplete data, were unable to be contacted or had a known or impending revision. Those who had revision were included in a Kaplan-Meier survivorship analysis. The included patients, deceased patients and those lost to follow-up were named group1, 2, and 3 respectively. Demographics and Knee society scores(KSS) were studies for all 3 groups. This was to identify any exclusion bias. Presence and severity of anterior knee pain as well as radiographic factors were collected for group 3. Logistic regression analysis was used to identify and variables that influenced the KSS and presence of anterior knee pain. Kaplan-Meier survivorship analysis was performed for patellar revision and tibial/femoral revision endpoints.

Results: 144 patients with 175 TKA were included in this study. They were on average 66 years old, 64% female, had a BMI of 30 and had a diagnosis of OA 92% of the time. Their average f/u was 11.3 years. Groups 2 and 3 had similar demographics but of course a much shorter f/u. Group 1 had a pre-op KSS of 84 a post-op KSS of 151 and a KS change score of 67. Groups 2 and 3 had similar pre-op, post-op and KSS change scores. We found anterior knee pain occurred in 5% of patients with an average severity of 5/10. Linear regression analysis did not identify any variables including radiographic parameters that had an independent influence on KSS or anterior knee pain. Kaplan-Meier survivorship with patellar revision for any reason as an endpoint was 96% at 10 years and 94% at 17 years. 20 patella were known to have had a revision or were undergoing a revision.

Conclusion: We conclude that use of an inset patellar component can give excellent durable results over time with a low rate of anterior knee pain and complications


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 24 - 24
1 Mar 2010
MacDonald SJ Charron K Bourne RB McCalden RW Naudie DD Rorabeck CH
Full Access

Purpose: Gender specific total knee replacement design has been a recently debated controversial topic. The purpose of this study was to investigate the survivor-ship and clinical outcomes of a large primary total knee arthroplasty cohort, specifically assessing any differences between gender groups.

Method: A consecutive cohort of 3817 patients with osteoarthritis, having undergone 5289 primary total knee replacements (3100-female, 2179-male) with a minimum of 2 years follow-up were evaluated. All surgeries were performed at the same institution by one of four surgeons. Pre-operative scores, latest scores, and change in clinical outcome scores (KSCRS, SF12, WOMAC) were compared and tested for significance using the students t-test. Kaplan Meier (K-M) survivor-ship was determined and tested for significance and categorical variables were compared using chi-squared.

Results: Men were significantly taller and heavier than women, while women had significantly higher BMI’s (p< 0.0001). While men had higher raw scores preoperatively, women demonstrated statistically greater improvement (p< 0.019) in all WOMAC domains including pain (29.87 vs. 27.30), joint stiffness (26.78 vs. 24.26), function (27.21 vs. 23.09) and total scores (28.34 vs. 25.09) There were no gender differences in improvements of the SF12 scores. Men demonstrated statistically greater improvement (p< 0.0001) in Knee Society function (22.10 vs. 18.63) and total scores (70.01 vs. 65.42), but not the Knee Society knee score (47.83 vs. 46.64, p=0.084). K-M cumulative survivorship at 10 years was 87.4±.01 for females and 82.9±.014 for males. K-M survivorship distribution was found to be significantly different between gender groups (p< 0.013, Mantel-Cox, Breslow, Tarone-Ware). Revision rates were 10.2% for males and 8.3% for females which was found to be significant by crosstabs with chi-squared (p=0.006).

Conclusion: In this cohort of patients undergoing total knee replacements, women demonstrated statistically greater implant survivorship, statistically greater improvement in WOMAC scores and less improvement in KSCR scores, leading one to question the hypothesis of an inferior clinical outcome in total knee arthroplasty that is gender based.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 250 - 250
1 May 2009
Bourne R MacDonald SJ McCalden RW
Full Access

The purpose of this study was to assess the influence of patient factors on six to eleven year TKR outcomes.

Three hundred and sixty-five consecutive patients (436 Genesis II TKR’s) were prospectively analyzed according to gender, diagnosis, body mass index, pre-operative deformity, pre-operative range of motion and implant type.

The Kaplan-Meier survivorship for the TKR patients was 98% ±.8% at nine years. Large and significant improvement in pre-operative health related quality of life (HRQL) outcomes (KSCR, WOMAC and SF-12) were noted Female patients demonstrated significantly worse pre-operative and post-operative KSCR, WOMAC and SF-12 scores but similar change scores and decreased post-operative range of motion compared to their male counterparts. Patients with rheumatoid arthritis had significantly inferior pre-operative and post-operative HRQL indices, but similar change scores. Rheumatoid patients achieved greater post-operative range of motion than patients with osteoarthritis. Patients with a body mass index > 30 had significantly less pre-operative and one year range of motion, but beyond two years follow-up health-related quality of life indices and range of motion were similar to other BMI categories. Pre-operative deformity did not affect patient outcome. Pre-operative range of motion had a significant effect on post-operative range of motion. Comparable outcomes were achieved with both posterior cruciate ligament preserving and sacrificing total knee replacements; however, the posterior cruciate ligament sacrificing implants had significantly greater postoperative range of motion.

With a contemporary total knee replacement with 98% Kaplan-Meier survivorship at nine years, male gender, a diagnosis of osteoarthritis and a good pre-operative range of motion were indicators of improved post-operative outcomes. Change scores of health-related outcomes are a better indicator of efficacy than simply noting pre- and post-operative scores.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 250 - 251
1 May 2009
Tammachote N Bourne RB MacDonald SJ McCalden RW Naudie D Rorabeck CH
Full Access

In patients with previous patellectomy the optimal constrained implant is not well understood. Previous outcome studies have shown contradictory results. There interpretation is limited by small number of patients, included primary and revision implants or involved a heterogeneous group of different constraint implants.

We performed retrospective match controlled analysis of a posterior stabilised primary total knee arthroplasty in forty-two patients who had previous patellectomy. There were nineteen male and twenty-three female patients. The average age of patients at the time of surgery was fifty-nine years (range from forty-one to seventy-four years). The average time from patellectomy to total knee arthroplasty was seventeen years (range from one to thirty-four years). The average duration of follow-up was 5.3 years with minimum two years follow up (range from two to sixteen years). The control group was matched by age, sex, prosthesis type and surgeon. We used the student-t test to compare the outcome measurement.

Preoperatively, the patellectomy and control groups were not significantly different in terms of Knee Society clinical and functional scores or range of motion. Postoperatively clinical component of the knee society score had a significant difference (p< 0.05) however the functional part of the knee society score didn’t (p> 0.05). In patellectomy group the postoperative clinical and functional score were equal to seventy and fifty-eight respectively. The average clinical component of knee society score in the patellectomy group was twelve points (SE=4.8) lower compare to the knee with intact patella. The patellectomy group also had higher extension lag and poorer extension (higher flexion contracture) at the most recent follow up (p< 0.05).

This study demonstrated the outcome of the largest series of primary total knee arthroplasty with posterior stabilised implant in patient with previous patellectomy. The outcome of surgery was significantly improved but not as good as the knee with intact patella especially the function of the extensor mechanism.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 238 - 239
1 May 2009
McCalden R Bourne RB Charron K Chess D MacDonald SJ Rorabeck CH McCalden R
Full Access

This study reports on the clinical and wear performance of a prospective randomised controlled trial comparing highly cross-linked (XLPE) to conventional polyethylene (PE) in total hip arthroplasty at five years minimum follow-up.

One hundred patients enrolled in a prospective randomised controlled trial received identical hybrid total hip arthroplasties with the exception of the polyethylene insert. Fifty patients received a PE liner (2.5 MRads; gamma-in-nitrogen sterilization) and fifty patients received a XLPE liner (10Mrads; gas-plasma sterilization). Clinical outcomes were determined using Harris Hip, WOMAC and SF-12 scores by an independent study nurse. Femoral head penetration rates were determined using a validated radiographic technique (Hip Analysis Suite 8.0.1.1) based on radiographs at six weeks, one year and yearly post-operatively. Linear regression analysis was performed for both the entire polyethylene groups and on each patient, where the slope represents the steady state head penetration rate (after bedding in) from one to five years follow-up.

None of the patients were lost to follow-up, however, nine patients were deceased before their five year follow-up. Two patients have been revised for loose stems. At average follow-up of 6.0 years (range 5.1–6.8 years), there were no differences in Harris Hip, WOMAC or SF-12 scores. XLPE had a significantly lower (p= 0.03) steady-state head penetration rate of 0.018 mm/year compared to 0.050 mm/year for XLPE (approximately 64% reduction). Analysis of individual patient’s head penetration rates demonstrated a similar significantly lower rate with XLPE (0.004 ± 0.067 mm/year) compared to PE (0.045 ± 0.083 mm/year). Interestingly, when examined by gender, the male PE group had a significantly higher head penetration rate (0.081 ± 0.084 mm/year) than both the male and female XLPE (−0.013 ± 0.104, 0.011 ± 0.074 mm/year, respectively).

At minimum five years follow-up, there were no clinical differences between groups. After bedding-in, there was a significant lower head penetration rate with XLPE compared to PE. Thus, mid-term follow-up appears to demonstrate a significant wear reduction (based on head penetration rates) afforded by first generation XLPE. Long-term follow-up is required to demonstrate the clinical benefit of this new material.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 230 - 230
1 May 2009
Bell T Bourne RB MacDonald SJ McCalden RW Naudie DR Ralley F
Full Access

The purpose of this study was to evaluate the impact of dalteparin use on transfusion rates and blood loss in patients undergoing primary total joint arthroplasty at our center.

We prospectively studied the transfusion patterns of 1642 patients who underwent primary total hip or knee arthroplasty between January 2004 and December 2005 by five arthroplasty surgeons. The influence of daltaperin use, release of tourniquet in total knee arthroplasty, and the turnover of house staff were analyzed using SPSS V14.0 statistical software.

We identified seven hundred and three total hip and nine hundred and thirty-nine knee arthroplasty patients. The mean haemoglobin drop was statistically significant between 2004 and 2005 (p< 0.001). This was seen in both hip (p=0.014) and knee (p< 0.001) patients. Subgroup analysis of total knee arthroplasty revealed a significant difference in haemoglobin drop between surgeons who released the tourniquet prior to closure compared to release at the end of the case (p=0.005). In addition, there were significant monthly differences that corresponded with the turnover of house staff (p=0.039). Overall, no statistically significant increase in allogeneic transfusion rates was observed between years, months, and individual surgeons.

The use of dalteparin was found to be associated with a significantly increased haemoglobin drop in primary total joint replacement when compared to warfarin. However, the use of dalteparin was not associated with an increase in allogeneic transfusions at our center. The results also suggest that there may be an advantage to releasing the tourniquet and achieving hemostasis prior to closure in knee arthroplasty. Finally, the results emphasise the importance of educating new house staff on methods to reduce intra-operative blood loss and transfusion rates.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 579 - 579
1 Aug 2008
Busch CA Shore BJ Bhandari R Ganapathy S MacDonald SJ Bourne RB Rorabeck CH McCalden RW
Full Access

Background: Post-operative analgesia using parenteral opioids or epidural analgesia can be associated with troublesome side effects.

Locally administered pre-emptive analgesia is effective, reduces central hyper sensitisation and avoids systemic drug related side-effects and may be of benefit in total knee replacement.

Materials and Methods: 64 patients undergoing total knee replacement were randomised to receive a periarticular intra-operative injection containing ropivacaine, ketorolac, epimorphine and epinephrine or nothing.

All patients received patient controlled analgesia (PCA) for 24 hours post surgery, followed by standard analgesia. Visual Analogue Scale (VAS) pain scores during activity and at rest and patient satisfaction scores were recorded pre and post operatively and at 6 week follow up. PCA consumption and overall analgesic requirement were measured.

Results: PCA use at 6,12 and over 24 hours post surgery was significantly less in patients receiving the injection (P< 0.01, P=0.016, P< 0.01). Patient satisfaction in PACU and 4 hrs post operation was greater (P=0.016, P=0.013). VAS for pain during activity in PACU and at 4 hrs were significantly less (P= 0.04, P=0.007) in the injected group. The average ROM at 6 weeks was no different. Overall hospital stay and the incidence of wound complications was not different between the two groups.

Conclusion: Peri-articular intra-operative multimodal analgesia significantly reduces post-operative PCA requirement. Patient satisfaction was greater in the injection group.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 89 - 89
1 Mar 2008
Bourne RB Rorabeck CH MacDonald SJ McCalden RW Kelman D
Full Access

Femoral stem fracture occurred in five (2%) of 283 revision hip arthroplasties when extensively coated, distal fixation femoral implants were used. Common features were complex revisions, high body mass index, poor proximal support, smaller stems (< 13.5 mm) and use of an extended trochanteric osteotomy. Use of strut allografts can reduce femoral stem stresses.

The purpose of this study was to analyze the surgical factors associated with fracture of cementless distal fixation revision femoral stems and supplement this analysis with a finite element analysis.

Data from our institutional joint replacement database identified five (2%) fractured femoral stems (three Solution, two Echelon) in a cohort of two hundred and eighty-three cementless distal fixation femoral stems (one hundred and eighty-two Solution, one hundred and one Echelon) followed over two years. Patient, surgical and implant factors were compared between the fractured and not fractured stems. Finite element analysis was performed on two fractured stem cases to better understand the fracture mechanism.

Common clinical features of the five fractured stems were complex revisions, high patient body mass index, poor proximal bone support, smaller stems (< 13.5 mm) and use of an extended trochanteric osteotomy (ETO) (3/5). Fatigue failure was the mode failure in all cases.

Finite element analysis confirmed that the location of highest stem stress was near the location of the stem fracture and that use of a strut graft over an extended trochanteric osteotomy in patients lacking proximal femoral cortical support decreased the stem stresses by 48%.

Use of cementless distal fixation revision femoral stems is accompanied by a 2% risk of stem fracture in the face of proximal femoral support of the stem and/or use of a stem with a diameter less than 13.5 mm. When an extended trochanteric osteotomy is used, the stem fracture rate increased to 4%. Use of a strut allograft in conjunction with the ETO can reduce stem stresses by 48% and the risk of stem fracture.

Funding: Research support from J& J DePuy and Smith & Nephew