header advert
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 84-B, Issue 6 August 2002

W. P. Butt J. Walkowiak

FUSION OF THE LUMBAR SPINE Pages 783 - 794
Access Required

Annotation
Access Required
J. Bartoniček

The designation German ‘Adam Bogen’ (arch) which is the used in the German literature as a description of the thick medial cortex of the femoral neck is incorrect. This arch was described by Robert Adams (1795-1871), who was an Irish anatomist and surgeon. Adams, Colles and Smith were outstanding surgeons who described fractures of the proximal femur in detail during the first half of the 19th century and who together formed the Dublin Surgical School. The most important aspects of these fractures were described between 1818 and 1839.


Y. Murata K. Takahashi M. Yamagata H. Sameda H. Moriya

In patients who underwent autogenous iliac bone grafting we studied prospectively injury to the lateral femoral cutaneous nerve (LFCN) in relation to the size (length, depth, width) of the graft. We also examined the neurological deficit, by questioning them about numbness and/or pain in the lateral thigh.

The risk of injury was significantly higher in those in whom the depth of the graft was more than 30 mm. With regard to the length of the graft the incidence of nerve injury was 20% when the graft was 45 mm long or more, 16% when it was between 30 mm and 45 mm long, and 8% when it was less than 30 mm long. We should inform patients of the possibility of such injury, and take size into consideration when harvesting grafts from the ilium.


W. J. Harrison C. P. Lewis C. B. D. Lavy

We performed a prospective, blind, controlled study on wound infection after implant surgery involving 41 procedures in patients infected with the human immunodeficiency virus (HIV) and 141 in HIV-negative patients. The patients were staged clinically and the CD4 cell count determined. Wound infection was assessed using the asepsis wound score. A risk category was allocated to account for presurgical contamination.

In HIV-positive patients, with no preoperative contamination, the incidence of wound infection (3.5%) was comparable with that of the HIV-negative group (5%; p = 0.396). The CD4 cell count did not affect the incidence of infection (r = 0.16). When there was preoperative contamination, the incidence of infection in HIV-positive patients increased markedly (42%) compared with that in HIV-negative patients (11%; p = 0.084).

Our results show that when no contamination has occurred implant surgery may be undertaken safely in HIV-positive patients.


Trauma
Access Required
E. K. Alpar G. Onuoha V. V. Killampalli R. Waters

We investigated the response of chronic neck and shoulder pain to decompression of the carpal tunnel in 38 patients with whiplash injury. We also determined the plasma levels of substance P (SP) and calcitonin gene-related peptide (CGRP), which are inflammatory peptides that sensitise nociceptors. Compared with normal control subjects, the mean concentrations of SP (220 v 28 ng/l; p < 0.0001) and CGRP (400 v 85 ng/l; p < 0.0005) were high in patients with chronic shoulder and neck pain before surgery. After operation their levels fell to normal. There was resolution of neurological symptoms with improvement of pain in 90% of patients. Only two of the 30 with chronic neck and shoulder pain who had been treated conservatively showed improvement when followed up at two years.

In spite of having neuropathic pain arising from the median nerve, all these patients had normal electromyographic and nerve-conduction studies. Chronic pain in whiplash injury may be caused by ‘atypical’ carpal tunnel syndrome and responds favourably to surgery which is indicated in patients with neck, shoulder and arm pain but not in those with mild symptoms in the hand. Previously, the presence of persistent neurological symptoms has been accepted as a sign of a poor outcome after a whiplash injury, but our study suggests that it may be possible to treat chronic pain by carpal tunnel decompression.


J. A. Garcia R. Mykula D. Stanley

Between 1995 and 2000, 19 consecutive patients with fractures of the distal humerus were treated by primary total elbow replacement using the Coonrad-Morrey prosthesis. No patient had inflammatory or degenerative arthritis of the elbow. The mean age at the time of injury was 73 years (61 to 95). According to the AO classification, 11 patients had suffered a C3 injury, two a B3 and two an A3. One fracture was unclassified. Two patients died from unrelated causes and one was unable to be assessed because of concurrent illness.

The mean time to follow-up was three years (1 to 5.5). At follow-up 11 patients (68%) reported no pain, four (25%) had mild pain with activity and one had mild pain at rest. The mean flexion arc was 24° to 125°. The mean supination was 90° (70 to 100) and pronation 70° (50 to 110). No elbow was unstable. The mean Disabilities of the Arm, Shoulder and Hand score was 23 (0.92 to 63.3) and the mean Mayo elbow performance score was 93 (80 to 100). Of the 16 patients, 15 were satisfied with the outcome.

Radiological evaluation revealed only one patient with a radiolucent line at the cement-bone interface. It was between 1 and 2 mm in length, was present on the initial postoperative radiograph and was non-progressive at the time of follow-up.

Primary total elbow arthroplasty is an acceptable option for the management of comminuted fractures of the distal humerus in elderly patients when the configuration of the fracture and the quality of the bone make reconstruction difficult.


W. Schneider N. Aigner O. Pinggera K. Knahr

We have compared different types of intertrochanteric osteotomy for avascular of necrosis of the hip and evaluated their performance in the light of improving outcome after total hip arthroplasty (THA). During a period of 14 years we performed 63 flexion osteotomies (partly combined with varus or valgus displacement), 29 rotational osteotomies, 13 varus osteotomies, eight medialising osteotomies and two extension osteotomies. The mean period of follow-up for all 115 operations was 7.3 years (maximum 24.6).

At follow-up, 27 of 29 patients with a rotational osteotomy had already undergone a THA, compared with 36 of 63 after flexion osteotomy. A high incidence of complications (55.2%) was seen early after rotational osteotomy, compared with 17.5% after flexion osteotomy.

For all osteotomies there was a high correlation between the size of the necrotic area and the incidence of failure, which also correlated with the preoperative Ficat and Steinberg stages. Using Kaplan-Meier survivorship analysis, Sugioka’s rotational osteotomy showed a survival probability after five years of 0.26 (95% confidence interval 0.49 to 0.14), and after ten years of 0.15 (CI 0.36 to 0.06). The survival probability for flexion osteotomy was 0.70 (CI 0.83 to 0.59) after five years and 0.50 (CI 0.65 to 0.38) after ten years. The subgroup of flexion osteotomy with a necrotic sector of less than 180° achieved the best survival probability of 0.90 (CI 1.00 to 0.80) after five years and 0.61 (CI 0.84 to 0.45) after ten years.

The indications for intertrochanteric osteotomy for avascular necrosis of the hip have to be addressed critically. Even flexion osteotomy in cases with small areas of necrosis provides only temporary benefit. Rotational osteotomy was associated with a high incidence of complications.


W. J. van Doorn B. L. E. F. ten Have F. C. van Biezen W. C. J. Hop A. Z. Ginai J. A. N. Verhaar

We report the initial results of an ongoing randomised, prospective study on migration of the Exeter and Elite Plus femoral stems after impaction allografting, as measured by radiostereometry.

Clinically, the impaction technique gave good results for both stems. The mean subsidence in the first year was 1.30 mm and 0.20 mm for the Exeter and the Elite Plus stems, respectively. In the second year, the Exeter stem continued to subside further by a mean of 0.42 mm, while the Elite Plus stem did not do so. Subsidence of the Exeter stem correlated with deficiency of bone stock as graded on the Gustilo and Pasternak scale. This correlation was not found for the Elite Plus stem. None of the other parameters which were studied predisposed to subsidence. There was no significant association between the amount of subsidence and the radiological appearance of the graft for either stem. Our findings do not support the theory that radial compression, due to subsidence of the Exeter stem, is the essential stimulus for remodelling in impaction allografting.


B. Espehaug O. Furnes L. I. Havelin L. B. Engesæter S. E. Vollset

Using data from the Norwegian Arthroplasty Register, we have the assessed survival of 17 323 primary Charnley hip prostheses in patients with osteoarthritis based upon the type of cement used for the fixation of the implant.

Overall, 9.2% had been revised after follow-up for ten years; 71% of the failures involved aseptic loosening of the femoral component. We observed significantly increased rates of failure for prostheses inserted with CMW1 and CMW3 cements. Using implants fixed with gentamicin-containing Palacos cement as the reference, the adjusted Cox regression failure rate ratios were 1.1 (95% CI 0.9 to 1.4) for implants cemented with plain Palacos, 1.1 (95% CI 0.7 to 1.6) for Simplex, 2.1 (95% 1.5 to 2.9) for gentamicin-containing CMW1, 2.0 (95% CI 1.6 to 2.4) for plain CMW1 and 3.0 (95% CI 2.3 to 3.9) for implants fixed with CMW3 cement. The adjusted failure rate at ten years varied from 5.9% for implants fixed with gentamicin-containing Palacos to 17% for those fixed with CMW3.


L. I. Havelin B. Espehaug L. B. Engesæter

We have compared the survival of two hydroxyapatite (HA)-coated cups, 1208 Atoll hemispheric and 2641 Tropic threaded, with cemented Charnley all-polyethylene cups (16 021) using the Cox regression model.

The Tropic cup used in combination with an alumina ceramic femoral head, had good results, similar to those of the Charnley cup. When used in combination with a stainless-steel head, however, the risk of revision beyond four years was increased 3.4 times for the Tropic cup compared with the Charnley cup (p < 0.001). Over the same period, the Atoll cup had an increased risk of revision of 3.8 times when used with the alumina heads (p < 0.001) and an increased risk of 6.1 times when used with stainless-steel heads (p < 0.001). Revision because of wear and osteolysis was more common with both types of HA-coated cup than with the Charnley cup. The rate of revision of the Atoll cup because of aseptic loosening was also increased.

We found that HA-coated cups did not perform better than the Charnley cup.


Knee
Access Required
C. M. Gupte A. Smith I. D. McDermott A. M. J. Bull R. D. Thomas A. A. Amis

The meniscofemoral ligaments were studied in 84 fresh-frozen knees from 49 cadavers. Combined anterior and posterior approaches were used to identify the ligaments. In total, 78 specimens (93%) contained at least one meniscofemoral ligament. The anterior meniscofemoral ligament (aMFL) was present in 62 specimens (74%), and the posterior meniscofemoral ligament (pMFL) in 58 (69%). The 42 specimens (50%) in which both ligaments were present were from a significantly younger population than that with one MFL or none (p < 0.05). Several anatomical variations were identified, including oblique fibres of the posterior cruciate ligament (PCL), which were seen in 16 specimens (19%). These were termed the ‘false pMFL’.

The high incidence of MFLs and their anatomical variations should be borne in mind during arthroscopic and radiological examination of the PCL. It is important to recognise the oblique fibres of the PCL on MRI in order to avoid wrongly identifying them as either a pMFL or a tear of the lateral meniscus. The increased incidence of MFLs in younger donors suggests that they degenerate with age.


Access Required
M. R. Norton R. K. Vhadra A. J. Timperley

We have found poor mid-term results in a multisurgeon series of 94 Johnson-Elloy (Accord) total knee replacements. A total of 27 knees (29%) has required revision, in 26 for aseptic loosening. Only 18 (19%) remain in situ, and these give poor function, are painful and most show radiological evidence of early failure. At 12 to 13 years the survival rate is 43% (confidence interval 29 to 57) with failure requiring revision as the endpoint. Proximal migration of the femoral component is associated with considerable loss of bone stock. We believe that all patients who have this implant should be recalled for regular review in order to anticipate this problem.


J. Herald L. Cooper F. Machart

Many knee surgeons flex the knee and sometimes also extend the hip before inflating a tourniquet on the thigh. This practice stems from the belief that these manoeuvres prevent excessive strain on the quadriceps during surgery, the assumption being that movement of the muscle is restricted by an inflated tourniquet. We therefore examined, using ultrasound, the movement of the quadriceps muscle above and below the tourniquet before and after inflation.

We applied a tourniquet of standard size to the thigh of five volunteers for approximately five minutes. A bubble of air was injected into the quadriceps muscle above the tourniquet and was the proximal point of reference. The musculotendinous junction was the distal point. The movement of the reference point was measured by ultrasound before and after inflation of the tourniquet. Each measurement was repeated with either the knee flexed and the hip extended, or the hip flexed and the knee extended. The mean and standard deviation were recorded.

Before inflation the mean amount of passive movement was 1.1 ± 0.13 cm proximal and 4.0 ± 0.08 cm distal to the tourniquet, with a range of movement of the knee of 0° to 137° (6.7°). After inflation the mean passive movement was 1.0 ± 0.07 cm proximal and 4.0 ± 0.08 cm distal to the tourniquet with a range of 0° to 132° (± 7.6°).

The ultrasound findings therefore have shown no evidence of restriction of the quadriceps muscle by an inflated tourniquet.


M. R. Reed W. Bliss J. L. Sher K. P. Emmerson S. M. G. Jones P. F. Partington

We undertook a prospective, randomised study of 135 total knee arthroplasties to determine the most accurate and reliable technique for alignment of the tibial prosthesis. Tibial resection was guided by either intramedullary or extramedullary alignment jigs.

Of the 135 knees, standardised postoperative radiographs suitable for assessment were available in 100. Correct tibial alignment was found in 85% of the intramedullary group compared with 65% of the extramedullary group (p = 0.019).

We conclude that intramedullary guides are superior to extramedullary instruments for alignment of the tibial prosthesis.


K. Nakagawa Y. Wada M. Minamide A. Tsuchiya H. Moriya

We examined an39 patients (45 knees) who had undergone Elmslie-Trillat procedure for recurrent or habitual dislocation of the patella with a follow-up of more than ten years. The mean age at the time of surgery was 18.4 years; the mean follow-up was 161 months (120 to 238). Using Fulkerson’s functional knee score, 41 knees (91%) had an excellent or good result at a mean follow-up of 45 months, and this was maintained in 29 (64%) at the final review.

The main cause of deterioration in the clinical results was the onset or worsening of patellofemoral joint pain, not patellar instability.


P. Wicart E. Mascard G. Missenard J. Dubousset

Failure of massive knee endoprostheses implanted for malignant tumours of the distal femur in children presents a difficult problem.

We present the results of rotationplasty undertaken under these circumstances in four boys. They had been treated initially at a mean age of 9.5 years for a stage-IIB malignant tumour of the distal femur by resection and implantation of a massive knee endoprosthesis. After a mean period of eight years and a mean of four operative procedures, there was failure of the endoprosthesis because of aseptic loosening in two and infection in two. Function was poor with a mean Musculoskeletal Tumor Society score of 7.5/30, and considerable associated psychological problems.

At a mean follow-up of 4.5 years after rotationplasty there was excellent function with a mean score of 27.5/30 and resolution of the psychological problems.


Eosinophilic granuloma Pages 870 - 872
Access Required
F. Plasschaert C. Craig R. Bell W. G. Cole J. S. Wunder B. A. Alman

Localised Langerhans-cell histiocytosis of bone (eosinophilic granuloma) is a benign tumour-like condition with a variable clinical course. Different forms of treatment have been reported to give satisfactory results. However, previous series all contain patients with a wide age range. Our aim was to investigate the effect of skeletal maturity on the rate of recurrence of isolated eosinophilic granuloma of bone excluding those arising in the spine.

We followed up 32 patients with an isolated eosinophilic granuloma for a mean of five years; 17 were skeletally immature. No recurrences were noted in the skeletally immature group even after biopsy alone. By contrast, four of 13 skeletally mature patients had a recurrence and required further surgery. This suggests that eosinophilic granuloma has a low rate of recurrence in skeletally immature patients.


R. D. Lackman L. D. Khoury A. Esmail R. Donthineni-Rao

Giant-cell tumours of the sacrum are difficult to treat. Surgery carries a high risk of morbidity, local recurrence and mortality. Radiation is effective in some patients, but has a risk of malignant change.

We evaluated the effectiveness of serial arterial embolisation as an alternative to surgery. Five patients with giant-cell tumours of the sacrum which had been primarily treated by serial embolisation were retrospectively reviewed for changes in the size of the tumour. In four the symptoms resolved with full return of function and arrest in the growth of the tumour. They remained free from growth, recurrence, or metastases at follow-up (4 to 17 years). One patient died from metastatic disease within 18 months of the initial diagnosis.


Children's Orthopaedics
Access Required
H. Düppe L. G. Danielsson

Between 1956 1999, 132 601 living children were born in and Malmö, and screened for neonatal instability of the hip. All late diagnosed patients have been followed and re-examined clinically and radiologically. During the first years of screening, less than five per 1000 living newborn infants were treated. This figure increased to 35 per 1000 in 1980, but later diminished again to about six per 1000 annually after 1990. The number of referred cases decreased from 45 per 1000 in 1980 to between 10 to 15 per 1000 from 1990. During the period of high rates of referral and treatment a larger number of paediatricians were involved in the screening procedure than during the periods with low rates of referral and treatment. Altogether 21 patients (0.16 per 1000) with developmental dislocation of the hip were diagnosed late, after one week. At follow-up, 18 were free from symptoms and 15 considered to be radiologically normal.


K. J. Holen A. Tegnander T. Bredland O. J. Johansen O. D. Sæther S. H. Eik-Nes T. Terjesen

The aim of this study was to evaluate whether universal (all neonates) or selective (neonates belonging to the risk groups) ultrasound screening of the hips should be recommended at birth.

We carried out a prospective, randomised trial between 1988 and 1992, including all newborn infants at our hospital. A total of 15 529 infants was randomised to either clinical screening and ultrasound examination of all hips or clinical screening of all hips and ultrasound examination only of those at risk. The effect of the screening was assessed by the rate of late detection of congenital or developmental hip dysplasia in the two groups.

During follow-up of between six and 11 years, only one late-detected hip dysplasia was seen in the universal group, compared with five in the subjective group, representing a rate of 0.13 and 0.65 per 1000, respectively. The difference in late detection between the two groups was not statistically significant (p = 0.22).

When clinical screening is of high quality, as in our study, the effect of an additional ultrasound examination, measured as late-presenting hip dysplasia, is marginal. Under such circumstances, we consider that universal ultrasound screening is not necessary, but recommend selective ultrasound screening for neonates with abnormal or suspicious clinical findings and those with risk factors for hip dysplasia.


A. S. Rai T. K. F. Taylor G. H. H. Smith R. G. Cumming M. Plunkett-Cole

There is a close link between the embryological development of the musculoskeletal system and all other main organ systems. We report a prospective series of 202 patients with congenital vertebral abnormalities and document the associated abnormalities in other systems. There were 100 boys and 102 girls. In 153 there were 460 associated abnormalities, a mean of 2.27 abnormalities for each patient. Intravenous pyelography was carried out on 173 patients (85.6%) and ultrasonography on the remaining 29 (14.4%). Patients with genitourinary anomalies were more likely to have musculoskeletal (p = 0.002), gastrointestinal (p = 0.02) and cardiac abnormalities (p = 0.008) than those without genitourinary involvement. A total of 54 (26.7%) had at least one genitourinary abnormality, the most frequent being unilateral renal agenesis. There was urinary obstruction in six (3%). There was no association between genitourinary abnormality and the place of birth, parental age, birth order, level of spinal curvature, or the number, type and side of spinal anomaly. There was, however, a statistically significant association (p = 0.04) between costal and genitourinary abnormalities. The incidence of genitourinary abnormalities (26.7%) was similar to that of previously reported series. The diagnosis of a congenital vertebral abnormality should alert the clinician to a wide spectrum of possible associated anomalies most of which are of clinical importance.


M. Kelly J. M. McBirnie R. Burnett

The new Ionising Radiation (Medical Exposure) Regulations 2000 (IR (ME)ER) were implemented in January 2001. These regulations state that “the referrer must record in the patient’s notes that a radiograph was taken and what it showed”. As a result it is now incumbent upon the orthopaedic surgeon to document formally the findings of all requested radiographs. We present a case in which a left upper bronchial carcinoma was detected initially on a radiograph of the left shoulder. It highlights the importance of careful examination of the entire radiographic image and the documenting of the findings.


Access Required
A. J. Tindall A. A. Shetty C. Rand

We describe an unusual case of a postoperative bone cyst resulting from a retained fragment of surgical glove. We highlight some of the problems associated with gloves and suggest ways of safeguarding against similar complications.


M. Ding A. Odgaard C. C. Danielsen I. Hvid

Previous studies have shown that low-density, rod-like trabecular structures develop in regions of low stress, whereas high-density, plate-like trabecular structures are found in regions of high stress. This phenomenon suggests that there may be a close relationship between the type of trabecular structure and mechanical properties.

In this study, 160 cancellous bone specimens were produced from 40 normal human tibiae aged from 16 to 85 years at post-mortem. The specimens underwent micro-CT and the microstructural properties were calculated using unbiased three-dimensional methods. The specimens were tested to determine the mechanical properties and the physical/compositional properties were evaluated.

The type of structure together with anisotropy correlated well with Young’s modulus of human tibial cancellous bone. The plate-like structure reflected high mechanical stress and the rod-like structure low mechanical stress. There was a strong correlation between the type of trabecular structure and the bone-volume fraction. The most effective microstructural properties for predicting the mechanical properties of cancellous bone seem to differ with age.


X. Yuan L. Ryd K. E. Tanner L. Lidgren

We present a new approach for the accurate reconstruction of three-dimensional skeletal positions using roentgen single-plane photogrammetric analysis (RSPA). This technique uses a minimum of three markers embedded in each segment which allow continuous, real-time, internal skeletal movement to be measured from single-plane images, provided that the precise distance between the markers is known.

A simulation study indicated that the error propagation in this approach is influenced by focus position, object position, the number of control points, the accuracy of the previous measurement of the distance between markers and the accuracy of image measurement. For reconstruction of normal movement of the knee with an input measurement error of sd = 0.02 mm, the rotational and translational differences between reconstructed and original movement were less than 0.27° and 0.9 mm, respectively.

Our results showed that the accuracy of RSPA is sufficient for the analysis of most movement of joints. This approach can be applied in combination with force measurements for dynamic studies of the musculoskeletal system.


J. E. Bechtold V. Kubic K. Søballe

We have investigated whether the presence of polyethylene (PE) alone is sufficient to cause an aggressive periprosthetic tissue response, or whether certain mechanical interface conditions can allow bone to grow while in the presence of PE. An experimental implant was loaded in the presence and absence of particulate PE under stable and unstable conditions.

Bone with a thin, discontinuous fibrous membrane formed in both groups of stable implants, either in the presence or absence of PE. By contrast, a continuous fibrous membrane consistently formed in both groups of unstable implants. The membrane consisted of loose fibrous connective tissue when PE was absent, and dense connective tissue with macrophages and a synovial lining when PE was present. In this model, if the interface was stable, the presence of PE was not sufficient to prevent the formation of bone or to produce a phagocytic tissue response. Only when the interface was unstable did a fibrous membrane form, and only then in the presence of PE.


B. Liagre S. Moalic P. Vergne J. L. Charissoux D. Bernache-Assollant J. L. Beneytout

We describe a model which can be used for in vitro biocompatibility assays of biomaterials.

We studied the in vitro response of human osteoarthritis or rheumatoid arthritis fibroblast-like synoviocytes to Al2O3 or ZrO2 particles by analyzing the production of interleukin-1 (IL-1) and interleukin-6 (IL-6) and the metabolism of arachidonic acid via lipoxygenase and cyclo-oxygenase pathways.

Our results show that, in these cells and under our experimental conditions, Al2O3 and ZrO2 did not significantly modify the synthesis of IL-1 and IL-6 or the metabolism of arachidonic acid.


Is titanium so bad? Pages 931 - 931
Access Required



Author’s reply Pages 932 - 932
Access Required

Author’s reply Pages 932 - 932
Access Required

Access Required


Access Required

Access Required

Access Required