Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 24 - 24
8 May 2024
McKenna R Wong J Tucker A
Full Access

Muller-Weiss disease is an uncommon condition with unclear etiology and no gold standard treatment. The question arises; which joints to fuse? Although no consensuses prevail, one must postulate fusion should include those affected. Consequently, to establish an algorithm for its surgical management we set out to study clinical and radiographic features with use of SPECT-CT and a literature review.

57 consecutive feet presenting with Muller-Weiss disease analysed; 15 men, 25 women, age 22–84. Condition bilateral in 17, left side 16, right in 7 patients. Specific history and examination by senior author. Radiographic series and SPECT-CT obtained with surgery performed on significantly symptomatic feet. Measurements of Meary-Tomeno angles, anteroposterior thickness of navicular at the midpoint of each naviculo-cuneiform, alongside the medial extrusion distance and percentage of compression in each case performed. Poor correlation between Meary's angle and 1) degree of compression at naviculo-cuneiform joints, 2) degree of extrusion 3) compression vs extrusion using R2 coefficient of determination (invalidating Maceira et al. classification). In unilateral cases, extrusion significantly greater on affected side 94.7% (P< 0.001 Fisher exact test). Degree of extrusion significantly greater in bilateral than unilateral cases (p=0.004 unpaired T test). Valgus hindfoot and Meary's negative most common pattern with no correlation between heel alignment and Meary's R2 = 0.003. SPECT-CT useful to determine subtalar involvement in ‘stage 2 disease.’

Following review of cases and published literature we propose the following classification for Muller-Weiss disease with treatment algorithm. 3 Stage delineation; Stage 1 (Normal hindfoot alignment); 1A. Talonavicular disease only - Isolated Talonavicular arthrodesis 1B. Talonavicular + Subtalar; double medial or triple arthrodesis. Stage 2. Talonavicular + Naviculocuneiform; 2A. Adequate bone stock - Talo-naviculo-cuneiform arthrodesis, 2B. Inadequate bone stock +- subtalar disease; Talo-naviculo-cuneiform arthrodesis with tricortical bone graft (Mayich). Stage 3; Asymmetric ankle varus. Pantalar arthrodesis Double/triple/TNC/TAR arthrodesis with hindfoot re-alignment.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 118 - 118
1 Apr 2019
McKenna R Jacobs H Jones C Redgment A Talbot S Walter W Brighton R
Full Access

Introduction

In total knee arthroplasty, the aim is to relieve pain and provide a stable, functional knee. Sagittal stability is crucial in enabling a patient to return to functional activities. Knee implants with a medial pivot (MP) design are thought to more accurately reproduce the mechanics of the native joint, and potentially confer greater antero-posterior stability through the range of flexion than some other implant designs.

Aim

This study aims to compare the sagittal stability of four different total knee arthroplasty implant designs. Method

Comparison was made between four different implant designs: medial pivot (MP), two different types of cruciate retaining (CR1 and CR 2) and deep dish (DD). A cohort of 30 Medial Pivot (MP) knees were compared with matched patients from each of the other designs, 10 in each group. Patients were matched for age, body mass index and time to follow up.

Clinical examination was carried out by an orthopaedic surgeon blinded to implant type, and sagittal stability was tested using a KT1000 knee arthrometer, applying 67N of force at 30˚ and 90˚.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 119 - 119
1 Apr 2019
McKenna R Marsden-Jones D Walter W
Full Access

Introduction

Component positioning is of great importance in total hip arthroplasty (THA) and navigation systems can help guide surgeons in the optimal placement of the implants. We report on a newly developed navigation system which employs an inertial measurement unit (IMU) to measure acetabular cup inclination and anteversion.

Aims

To assess the accuracy of the IMU when used for acetabular cup placement and compare this with an established optical navigation system (ONS).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 120 - 120
1 Apr 2019
McKenna R Jacobs H Walter W
Full Access

Background

Accurate implant positioning is of supreme importance in total knee replacement (TKR). The rotational profile of the femoral and tibial components can affect outcomes, and the aim is to achieve coronal conformity with parallelism between the medio-lateral axes of the femur and tibia.

Aims

The aim of this study is to determine the accuracy of implant rotation in total knee replacement.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 76 - 76
1 Jan 2018
Marsden-Jones D McKenna R Jones C Walter W
Full Access

The pelvis is known to undergo significant movement during Total Hip Replacement (THR). We developed a 4D-tracking device employing an inertial measurement unit (IMU) to track changes in pelvic orientation during THR.

The IMU was mounted on the iliac crest in 39 cases with tracking initiated at the commencement of surgery and digital logging of significant intra-operative milestones (i.e. acetabular impaction). The system was validated by videoing a select number of cases and the 4D model linked in real-time. Data were processed using a custom Java-based infrastructure to calculate roll (left/right) and tilt (flexion/extension).

19 patients underwent direct anterior approach (DAA) and 20 posterior approach (PA). Comparing DAA to PA, at acetabular impaction there was mean pelvic roll seen of 3.7°(range 0.5–10.1°) in the DAA group, and 5.6°(range 0.1–16.2°) in the PA group. Mean tilt in the DAA group was 3.7°(range: 0.2–7.1°) and in the PA group was 1.7°(range: 0.2–4.3°).

Mean BMI in the DAA group was 25.2(range: 18.4–34.2) and 29.1(range: 21.5–42.4). There was no direct correlation between BMI and the amount of roll or tilt recorded for individual patients.

The IMU tracking device provided a useful and real-time method of assessing pelvic orientation during THR via both the DAA and posterior approach. Specific variations in tilt and roll are consistent with previous literature. Significant variation in the pattern of pelvic movement was noted to be dependent on the approach and the position of the patient on the operating table.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 26 - 26
1 May 2015
McKenna R Breen N Madden M Andrews C McMullan M
Full Access

Background:

Developing a successful outpatient service for Ilizarov frame removal provides both patient and cost benefits. Misinformation and patient trepidation can be detrimental to recovery and influence choices. Education may play an important role in tailoring an efficacious service.

Objective:

Review Belfast Regional Limb Reconstruction frame removal practice, introduce changes aimed at improving care and evaluate effects.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 63 - 63
1 Jul 2012
McKenna R Latif A McLeery M Chambers M Rooney B Leach W
Full Access

Aim

We aim to compare post-operative length of stay and cardiopulmonary morbidity in patients randomised to either navigated or conventional total knee arthroplasty (TKA).

Method

Patients undergoing primary TKA for osteoarthritis were prospectively assigned randomly to either navigation-guided or control groups and blinded to this.

All patients received a PFC implant (DePuy, Warsaw, IN). In the control group the standard femoral intramedullary and tibial extramedullary alignment rod was used. In the navigation group, the BrainLab (Munich, Germany) navigation system was used. All operations were carried out by one of two consultant orthopaedic knee surgeons.

Length of post operative hospital stay and the development of cardiopulmonary complication were recorded and groups compared.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 5 - 5
1 Jul 2012
McKenna R Winter A Rooney B Leach W
Full Access

Aim

We aim to compare revision rates and functional outcome scores in between two contemporary total knee arthoplasty systems.

Methods

A search was carried out of a prospectively maintained outcomes database to identify all patients receiving total knee replacement (TKR) in the department between 2005 and 2006, when evaluation of different knee arthroplasty systems was being undertaken. Data on the first 93 consecutive patients receiving a Scorpio (Stryker, Allendale, NJ) implant and the first 93 consecutively receiving a PFC (DePuy, Warsaw, IN) implant were reviewed. Four year revision rates and functional scores were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIII | Pages 17 - 17
1 Jul 2012
Murray O Lee S Mckenna R Kelly M Roberts J
Full Access

Early failure of metal-on-metal (MoM) total hip replacements (THR) is now well established. We review 93 consecutive patients with CPT¯ stems MoM THR. Our series demonstrates a new mechanism of failure, which may be implant combination specific.

Between January 2005 and June 2009, 93 consecutive MoM total hip replacements were preformed using CPT stems by 3 surgeons at our unit. 73 CPT¯ stems, Metasul¯ Large Diameter Heads (LDH) with Durom¯ acetabulae and 20 CPT¯ stems, Metasul¯ 28mm diameter heads in Allofit¯ shells (zimmer). Clinical outcomes were collected prospectively before surgery, at 3 months, 1 year, 2 years, 3 years, and at 5 years post surgery. Revision for any cause was taken as the primary endpoint and the roentgenograms and explanted prostheses were analyzed for failure patterns.

In the LDH/Durom¯ group a total of 13 (18%) patients required revision (figs. 1) at a median of 35 months (range 6-44). 6 (8%) for periprosthetic fracture. All 6 periprostethic fractures were associated with minimal or no trauma and all had ALVAL identified histologically.

To date there have been no failures in the CPT¯/28mm head Allofit¯ group. Several failures demonstrated bone loss in Gruen zones 8 ± 9 ± 10 (fig. 2).

We demonstrate an unacceptably high rate of failure in CPT¯ MoM LDH hip replacements, with a high failure secondary to periprosthetic fracture and postulate a mechanism associated with local toxicity to metal ions. We strongly advise against this combination of prosthesis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 84 - 84
1 Jul 2012
Winter A Thomson L Mckenna R Rooney B Raby N
Full Access

Aim

This study looks for correlation between pre-operative MRI and intra-operative surgical findings regarding the site of medial patellofemoral ligament (MPFL) rupture in first time patella dislocaters with the aim of confirming the reliability of this modality of imaging.

Methods

A retrospective analysis of all patients who were referred for MRI following patella dislocation was performed. The surgical and MRI findings of those who subsequently underwent MPFL repair were compared to look for any correlation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 43 - 43
1 Jun 2012
McKenna R Winter A Leach W
Full Access

Distal radial fractures are amongst the most common trauma referrals, however controversy remains regarding their optimum management. We undertook a retrospective review of the management of distal radial fractures in our department.

The prospectively maintained trauma database was used to identify patients admitted for operative management of a dorsally displaced distal radial fracture between June 2008 and June 2009. Only extra-articular or simple intra-articular fractures were included (AO classification A2/A3/C1/C2). Operation notes were reviewed to determine the method of fixation. Patients were contacted by post and asked to complete a functional outcome score - Disabilities of the Arm, Shoulder and Hand (DASH). A further 12 patients with similar fractures who had been managed conservatively were also asked to complete a DASH score to provide a comparison between operative and non-operative management.

98 patients were identified - 67 female, 31 male. Mean age was 51 years, range 15-85 years. All patients were at least 1 year post-op.

26 patients had manipulation under anaesthesia (MUA). 48 patients had MUA and K-wire fixation, which was supplemented with synthetic bone substitute in 16 cases. 3 patients had MUA and bone graft and 21 patients had open reduction and internal fixation (ORIF) with a volar plate.

34 correctly completed DASH scores were returned. A lower score equates to a better functional outcome. Mean DASH scores were: MUA 14.8; MUA+K-wire 13.1; ORIF 13.6; conservative 47.1.

This data would indicate that patients with a significantly displaced distal radial fracture have a better functional outcome with operative management to improve the fracture alignment. However, all of the methods of fixation used resulted in similar functional outcomes at one year.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 42 - 42
1 Jun 2012
McKenna R Latif A McLeery M Chambers M Rooney B Leach W
Full Access

We aim to compare post-operative length of stay and cardiopulmonary morbidity in patients randomised to either navigated or conventional total knee arthroplasty (TKA).

Patients undergoing primary TKA for osteoarthritis were prospectively assigned randomly to either navigation-guided or control groups and blinded to this.

All patients received a PFC implant (DePuy, Warsaw, IN). In the control group the standard femoral intramedullary and tibial extramedullary alignment rod was used. In the navigation group, the BrainLab (Munich, Germany) navigation system was used. All operations were carried out by one of two consultant orthopaedic knee surgeons.

Length of post operative hospital stay and the development of cardiopulmonary complication were recorded and groups compared.

100 patients were recruited (55 control vs 45 navigated). Patient demographics were similar in both groups.

Mean length of stay was 7 days in the control group (range 3-101), 5 days in the navigation group (range 3-10). The mode was 4 days in both groups.

7 patients (13%) stayed for >7 days in the control group, 3 patients (7%) stayed >7 days in the navigation group(p=0.339).

4 patients(7%) required >10 days inpatient stay in the control group, 0 patients required to stay in hospital for longer than 10 days in the navigation group(p=0.069).

The causes for the length of stay exceeding 10 days were pulmonary embolus in 3 patients, and chest infection in 1 patient.

Patients undergoing navigation-guided TKA required shorter post-operative inpatient stays than those undergoing arthroplasty using conventional techniques. Fewer patients in the navigation group required stays longer than 7 or 10 days. The difference in post-operative stay was associated with fewer respiratory complications in the navigated group.