header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 5 - 5
1 Jun 2023
Church D Pawson J Hilton C Fletcher J Wood R Brien J Vris A Iliadis A Collins K Lloyd J
Full Access

Introduction

External fixators are common surgical orthopaedic treatments for the management of complex fractures and in particular, the use of circular frame fixation within patients requiring limb reconstruction. It is well known that common complications relating to muscle length and patient function without rehabilitation can occur. Despite this there remains a lack of high-quality clinical trials in this area investigating the role of physiotherapy or rehabilitation in the management of these patients. We aim to complete a systematic review of rehabilitation techniques for patients undergoing external fixator treatment for Limb Reconstruction of the lower limb.

Materials & Methods

A comprehensive search of AMED, CINAHL, MEDLINE and COCHRANE databases was conducted to identify relevant articles for inclusion, using a search strategy developed in collaboration with a research librarian. Inclusion criteria consisted of adults aged 18 years and over who have experienced leg trauma (open fracture, soft tissue damage), elective leg deformity corrective surgery, bone infection or fracture non-union who have been treated with the use of an external fixator for fixation. Specific exclusion criteria were patients below the age of 18 years old, patients with cancer, treatment of the injury with internal nail, patients who underwent amputation, the use of external fixators for soft tissue contracture management, editorials, comment papers, review papers, conference proceedings and non-English papers.

Titles, abstracts, and full texts were screened for suitability by pairs of reviewers according to the inclusion and exclusion criteria using Rayyan QCRI online software. Any conflicts were resolved through discussion with three independent specialist senior reviewers. Following full text screening, references lists of included articles were manually searched to ensure that all relevant studies were identified. Due to lack of evidence, forward searching was also completed for studies included in the review. Data quality was assessed using the mixed methods appraisal tool and the CERT assessment tool was utilised to look at completeness of reporting of exercise interventions.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 8 - 8
1 Aug 2021
Clewes P Lohan C Stevenson H Coates G Wood R Blackburn S Tritton T Knaggs R Dickson A Walsh D
Full Access

Due to limitations of existing pharmacological therapies for the management of chronic pain in osteoarthritis (OA), surgical interventions remain a major component of current standard of care, with total joint replacements (TJRs) considered for people who have not responded adequately to conservative treatment. This study aimed to quantify the economic burden of moderate-to-severe chronic pain in patients with OA in England prior to TJR.

A retrospective, longitudinal cohort design was employed using Clinical Practice Research Datalink GOLD primary care data linked to Hospital Episode Statistics secondary care data in England. Patients (age ≥18 years) with an existing OA diagnosis of any anatomical site (Read/ICD-10) were indexed (Dec-2009 to Nov-2017) on a moderate-to-severe pain event (which included TJR) occurring within an episode of chronic pain. 5-year TJR rates from indexing were assessed via Kaplan-Meier estimates. All-cause healthcare resource utilisation and direct medical costs were evaluated in the 1–12 and 13–24 months prior to the first TJR experienced after index. Statistical significance was assessed via paired t-tests.

The study cohort comprised 5,931 eligible patients (57.9% aged ≥65 years, 59.2% female). 2,176 (36.7%) underwent TJR (knee: 54.4%; hip: 42.8%; other: 2.8%). The 5-year TJR rate was 45.4% (knee: 24.3%; hip: 17.5%; other: 6.8%). Patients experienced more general practitioner consultations in 1–12 months pre-TJR compared with 13–24 months pre-TJR (means: 12.13 vs. 9.61; p<0.0001), more outpatient visits (6.68 vs. 3.77; p<0.0001), more hospitalisations (0.74 vs. 0.62; p=0.0032), and more emergency department visits (0.29 vs. 0.25, p=0.0190). Total time (days) spent as an inpatient was higher in 1–12 months pre-TJR (1.86 vs. 1.07; p<0.0001). Mean total per-patient cost pre-TJR increased from £1,771 (13–24 months) to £2,621 (1–12 months) (p<0.0001).

Resource-use and costs incurred were substantially greater in the 12 months immediately prior to TJR, compared with 13–24 months prior. Reasons for increased healthcare and economic burden in the pre-TJR period deserve further exploration as potential targets for efforts to improve patient experience and efficiency of care.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_9 | Pages 3 - 3
1 May 2014
Wood R Granville-Chapman J Clasper J
Full Access

Surgical planning is the first step in operative fracture management. Complex situations are often faced which pose difficulties on both technical and logistic fronts. Surgical planning is the first step in operative fracture management. The degree of planning that is required is therefore determined by a number of factors including: the nature of the injury mechanism and its concomitant physiological insult, complexity of the fracture and region, expertise of the surgical team and equipment limitations. This paper explores a novel planning process in orthopaedic trauma surgery based upon British Military Doctrine. The seven questions of surgical planning represent a novel method that draws inspiration from the combat estimate process. It benefits from a global approach that encompasses logistic as well as surgical constraints. This, in turn, allows the surgical team to form an understanding of the nature of the fracture in order to develop, document and deliver a surgical plan. This has benefits for the operating surgeon, operating room practitioners and trainees alike and ultimately can result in improved patient care.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 36 - 36
1 Dec 2013
Cook R Shearwood-Porter N Nicolae C Bolland B Latham J Wood R
Full Access

Introduction:

Cemented femoral components have been used in hip replacement surgery since its inception. For many patients this works well, but recent retrieval studies1–4 and more fundamental studies5, 6 have highlighted the issues of damage and material loss from the both matt and polished cemented stems.

Materials and methods:

This study will focus on a cohort of retrievals from the Southampton Orthopaedics Centre for Arthroplasty Retrieval Surgery (SOCARS). The cohort consisted of a number of hybrid modular total hip replacements with cemented femoral components, both from mixed and matched manufacturer stem and head combinations. Femoral stems were polished, collarless, tapered designs; head sizes ranged from 28–54 mm. For each femoral stem, samples of Palacos R + G cement (Heraeus Medical GmbH, Hanau, Germany) were retrieved from the proximal region of the cement mantle (Gruen zones 1 and 7), corresponding to both macroscopically damaged and undamaged surfaces of the stem. The areas of damage were determined using calibrated digital photography; damaged surfaces were then imaged in detail using an Alicona InfiniteFocus microscope (Alicona Imaging GmbH, Graz, Austria). The technique uses optical microscopy and focus variation technology to extract 3D morphology and depth information from the surface with a resolution of 10 nm. A series of measurements were made and two different analysis routes were used to provide volumetric material loss measurements from the stem surface. High-resolution microscopy and elemental analysis of the cement and stem surfaces was conducted via SEM and EDX to identify the mechanisms leading to material loss at the cement-stem interface.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 12 - 12
1 Mar 2013
Bolland B Roques A Maul C Cook R Wood R Tuke M Latham J
Full Access

The poor outcome of large head metal on metal total hip replacements (LHMOMTHR) in the absence of abnormal articulating surface wear has focussed attention on the trunnion / taper interface. The RedLux ultra-precision 3D form profiler provides a novel indirect optical method to detect small changes in form and surface finish of the head taper as well as quantitative assessment of wear volume. This study aimed to assess and compare qualitatively tapers from small and large diameter MOMTHR's. Tapers from 3 retrieval groups were analysed. Group 1: 28mm CoCr heads from MOMTHRs (n=5); Group 2: Large diameter CoCr heads from LHMOMTHRs (n=5); Gp 3 (control): 28mm heads from metal on polyethylene (MOP) THRs; n=3). Clinical data on the retrievals was collated. RedLux profiling of tapers produced a taper angle and 3D surface maps. The taper angles were compared to those obtained using CMM measurements. There was no difference between groups in mean 12/14 taper angles or bearing surface volumetric and linear wear. Only LHMOMs showed transfer of pattern from stem trunnion to head taper, with clear demarcation of contact and damaged areas.3D surface mapping demonstrated wear patterns compatible with motion or deformations between taper and trunnion in the LHMOM group. These appearances were not seen in tapers from small diameter MOM and MOP THRs. Differences in appearance of the taper surface between poorly functioning LHMOMTHRs and well functioning MOP or MOM small diameter devices highlight an area of concern and potential contributor to the mode of early failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 18 - 18
1 Mar 2013
Bolland B Maul C Cook R Roques A Tuke M Wood R Latham J
Full Access

The poor outcome of large head metal on metal total hip replacements (LHMOMTHR) in the absence of abnormal wear at the articulating surfaces has focussed attention on the trunnion / taper interface. The RedLux ultra-precision 3D form profiler provides a novel indirect optical method to detect small changes in the form and surface finish of the head taper as well as a quantitative assessment of wear volume. This study aimed to assess and compare qualitatively the tapers from well functioning small diameter, with poorly functioning LHMOMTHR's using the above technique.

Method

3 groups of retrieval tapers were analysed (Group 1: 28 mm CoCr heads from well functioning MOMTHRs (n=5); Group 2: Large diameter CoCr heads from LHMOMTHRs revised for failure secondary to adverse reaction to metal debris (n=5); Gp 3 (control): 28 mm heads from well functioning metal on Polyethylene (MOP) THRs; n=3). Clinical data on the retrievals was collated. The Redlux profiling of modular head tapers involves a non direct method whereby an imprint of the inside surface of a modular head is taken, and this is subsequently scanned by an optical non contact sensor using dedicated equipment [1]. The wear was also measured on the bearing surface [1]. RedLux profiling of the tapers produced a taper angle and 3D surface maps. The taper angles obtained with the Redlux method were compared to those obtained using CMM measurement on 3 parts. The Redlux profiling, including imprints, was also repeated 3 times to gauge potential errors.

Results

There was no difference in mean 12/14 taper angles between groups. There was no difference in volumetric and linear wear at the bearing surface between groups. Only the LHMOMs showed transfer of pattern from the stem to the internal head taper, with clear demarcation of the contact and damaged area between head taper and stem trunnion (see figure 1 – interpretation of head taper surface features demonstrated using Redlux optical imaging). 3D surface mapping demonstrated wear patterns compatible with motion or deformations between taper and trunnion in the LHMOM group. These appearances were not seen in tapers from small diameter MOM and MOP THRs (see Figure 2).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 139 - 139
1 Jan 2013
Bolland B Maul C Cook R Roques A Wood R Latham J
Full Access

The poor outcome of large head metal on metal total hip replacements (LHMOMTHR) in the absence of abnormal wear at the articulating surfaces has focussed attention on the trunnion/taper interface. The RedLux ultra-precision 3D form profiler provides a novel indirect optical method to detect small changes in form and surface finish of the head taper as well as a quantitative assessment of wear volume. This study aimed to assess and compare qualitatively the tapers from small diameter with LHMOMTHR's. 3 groups of retrieval tapers were analysed (Group 1: 28mm CoCr heads from MOMTHRs (n=5); Group 2: Large diameter CoCr heads from LHMOMTHRs (n=5); Group 3: 28mm heads from metal on polyethylene (MOP) THRs; n=3). Clinical data on the retrievals was collated. Both bearing surfaces and head tapers were measured for wear using the Redlux profiling non contact measurement system. Measurements included taper angle and 3D surface maps. Taper angles obtained with the Redlux method were compared to those obtained using CMM measurement on 3 parts. The Redlux profiling, including imprints, was also repeated 3 times to gauge potential errors. There was no difference in mean 12/14 taper angles between groups. There was no difference in volumetric and linear wear at the bearing surface between groups. Only the LHMOMs showed transfer of pattern from the stem to the internal head taper, with clear demarcation of the contact and damaged area between head taper and stem trunnion. 3D surface mapping demonstrated wear patterns compatible with motion or deformations between taper and trunnion in the LHMOM group alone. Discussion: Differences in appearance of the taper surface between LHMOMTHRs and MOP or MOM small diameter devices highlight an area of concern and potential contributor to the mode of early failure. Further work is required to fully qualify the Redlux method capabilities.