header advert
Results 1 - 20 of 22
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 25 - 25
1 Mar 2017
Mitsui H Sugimoto K Sakamoto M
Full Access

Introduction

Achieving primary and long-term stability of femoral implant is critical for THA. This can be influenced by the shape and location of surface preparation as well as geometry. The Corail® stem has developed in 1986 in France, which is a straight quadrangular, and full HA coated standard titanium alloy stem featuring a metaphyseal tulip flare in combination with horizontal and vertical grooves. We have performed 75 THAs using it since May 2013. The purpose of this study was to evaluate radiographic changes of femur over time in Japanese patients after THA using this HA coated stem.

Materials and Methods

Between May 2013 and September 2015, we implanted 75 THAs using a Corail® stem (DePuy-Synthes) in 66 patients. Their ages at operation were 47 to 93 years (avg. 66.5 years). Durations of follow up were 6 to 34 months after implantation (avg. 13.7 months). Acetabular components were standard titanium alloy, either 37 Pinnacle Porocoat®, 19 Pinnacle Gription® (DePuy-Synthes), 8 Ranawat®, 5 Regenerex®, or 6 G7® (Zimmer-Biomet) uncemented cups. Heads were either 73 BIOLOX delta® ceramic (CeramTec) or 2 CoCr. Liners were either 56 Marathon® (DePuy-Synthes) or 19 E1® HXLPE (Zimmer-Biomet). We studied 74 hips except one hip which was revised due to infection at the time of 3 weeks after surgery. Postoperative radiographic evaluations were done at the time of 2, 4, 6, 9, 12 months and then every 6 months thereafter. We examined cancellous condensation, radiolucent line, osteolysis, cortical hypertrophy and stress shielding using both of plain X-ray and Tomosynthesis (Shimadzu, Japan).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 23 - 23
1 Feb 2017
Iguchi H Mitsui H Kobayashi M Nagaya Y Goto H Nozaki M Murakami S Shibata Y Fukui T Okumura T Otsuka T
Full Access

Introduction

Since 1989 we have been using custom lateral-flare stems. Using this stem, its lateral flare can produce high proximal fit and less fit in distal part. Applying this automatic designing software to the average femoral geometries, we can make off the shelf high proximal fit stem (Revelation ®). Putting the off the shelf stem, the original center of the femoral heads were well reproduced. But in DDH cases, severe deformities around hip sometimes make complicated difficulty for better functional reconstruction. They are high hip center such as Crowe II-IV, shortening of the femoral neck, high anteversion etc. DDH cases are well known to have higher anteversion than non DDH cases. There would be no definite explanations for it. The high anteversion would not always be harmful for the preoperative patients. But in some cases, osteophytes are observed at posterior side of the femoral head which make another sphere with different centre. We can guess that the patient's biomechanics had not been matched with the original anteversion. Then posterior osteophytes can correct inappropriate anteversion (self-reduction.) (Fig.1) In those patients, reduction of the anteversion by putting stems twisted into the canal or using modular stems are sometimes done by the surgeons' decision.

Younger DDH cases can also be treated with THA, because of the complicated deformities or biomechanical disorders. Short stems are expected to reduce operative invasion and stress shielding then can reserve bone quality and quantity. From these point of view to improve the understanding of the characteristics of the DDH anteversion, and design a DDH oriented short stem could be one of good solution for those cases.

Method

For the better understanding of the high anteversion 57 femora (mean anteversion: 34.4 deg.) were analyzed slice by slice. The direction of femoral head centre, lesser trochanter (LTR), linea aspera (aspera) just below LTR, aspera in the middle of the femur and aspera between the last 2 sections. All of the directions were assessed from PC line

To clarify the meaning of the head osteophytes, 35 operated cases were analyzed the extent of the head osteophytes.

According to the results, a DDH oriented short stem was designed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 45 - 45
1 May 2016
Iguchi H Mitsui H Kobayashi M Nagaya Y Goto H Nozaki M Watanabe N Shibata Y Shibata Y Fukui T Joyo Y Otsuka T
Full Access

Introduction

In DDH cases often have high anteversion. They also often have high hip center. THA for those cases sometimes requires subtrochanteric derotational/shortening osteotomy. To achieve good results of the surgery, accurate preoperative planning based on biomechanics of the high anteversion cases, method for accurate application of the plan, and stable fixation are very important. At ISTA 2008, we have reported that the location of the anteversion exist several centimeters below the lesser trochanter. Independently from the extent of anteversion, femoral head, grater trochanter, and lesser trochanter are aligned in the same proportion. We have also reported in 2007, in improper high anteversion cases, many cases grow osteophytes posterior side of femoral head to reduce it functionally. In 2014, we reported about development of the stem for subtrochanteric osteotomy. (ModulusR)[Fig.1] In the present study, we established systematic planning way for estimate proper derotation and shortening and apply it for the surgery.

Methods

Leg alignment during walking were well observed. According to the CT, 3D geometry of the femur, anteversion in hip joint and its compensation by the osteophyte, and knee rotation were measured. It was divided into proximal part and distal part at several centimeter below the lesser trochanter. Adequate hip local anteversion was determined by local original anteversion – compensation if IR-ER can be done. Keeping that anteversion for the proximal part, distal part was rotated as knee towards front. Thus derotation angle was decided. Using 3D CAD (Magics®) proper size of Modulus R was selected and overlapping with canal was extracted then its center of gravity was calculated. This level is decided as the height of osteotomy to obtain equal fixation to both proximal and distal part.[Fig.2] If the derotation angle is less than 15 degree, modular neck adjustment was selected first. By trial reduction and motion test, according to the instability osteotomy was performed. In the high hip center cases, original hip center was reconstructed. Shortening length was determined not to make leg elongation more than 3cm. ModulusR were used for the replacement and fixation of the osteotomy.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 46 - 46
1 May 2016
Iguchi H Okamoto H Mitsui H Kobayashi M Nagaya Y Goto H Nozaki M Takeichi Y Otsuka T
Full Access

Background

Infection is one of the most severe comlications of the total arthroplasty. We sometimes encounter cases, which are very hard to finish repeated recurrence. Usage of steroids, immunosuppressants, and biologics would possibly effect to the incidence of the prosthetic infection and to the result of its treatment. Biologics have drastically decreased the number of the total arthoplasic patients, on the other hand, we must be more careful about the infectious conditions. For the infection two stage revision surgery; first removal and antibiotics cement spacer insertion then reimplantation later; is often chosen but sometimes one time antibiotics cement spacer cannot stop the infection and requires multi times spacer insertion. In those cases the dead spaces, poor blood supply and tight skin could be the cause of the recurrence. For these cases we had been performing musclo-cutaneal flap and successfully finish the infection.

Objectives

Our objectives are to review infection cases treated with musclo-cutaneal flap and compare with treatment without it. Methods: Since 2004 to 2013, 6 infection cases were treated. Our standard policy is 2-staged revision. In the first surgery, the prosthesis was removed and cement spacer was inserted. If no evidence of the remained infection was found reimplantation would be done in the second surgery. Otherwise debridement and cement spacer were repeated. In 3 cases, the infection could be finished without musclo-cutaneal flap but in 3 cases musclo-cutaneal flap was finally done then the infection was finished. The clinical courses were reviewed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 42 - 42
1 Jan 2016
Mitsui H Iguchi H Nozaki M Watanabe N Goto H Nagaya Y Kobayashi M Otsuka T
Full Access

Objective

This study shows the radiographic results of total hip arthroplasty (THA) using the Revelation hip system® for hip joint disease.

Methods

We performed THA for hip disease using the Revelation Hip System®. From July 2007 to May 2009, 30cases (35 hips) were available for this study. Radiographic evaluation was performed at the last follow-up. Evaluation items included the presence or absence of subsidence, spot welds, demarcation line, cortical hypertrophy and stress shielding. The stem was designed to be implanted without cement and to be combined to the femur bone at the proximal portion to avoid stress shielding. Zone of Gruen zone 1 was divided into 1A or 1B, above and below the outermost tip of the lateral flare of the stem.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 56 - 56
1 Jan 2016
Iguchi H Mitsui H Murakami S Kobayashi M Nagaya Y Nozaki M Goto H Watanabe N Shibata Y Shibata Y Fukui T Otsuka T
Full Access

Introduction

Since 1989, we have been developing lateral flare stem. The concept of lateral flare stem is to deliver proximal part big enough to fill the proximal cavity that most of the cement stems can fill and most of the cementless stems cannot. Also having distal part polished, much less distal load transfer occurs than cement stem. Thus, we can expect high proximal load transfer to prevent stress shielding. To deliver lateral flare stem, straight insertion path cannot be available, as proximal lateral part to fill inside the greater throchanter collides to the greater trochanter. So 3-Dimension insertion path was calculated to deliver that part through the narrow made by neck osteotomy. The first generation of the lateral flare stem was custom made. The second generation was designed as an off-the-shelf stem from what we have learned by the experience of custom stems. With the third generation, the stem was shortened to achieve more proximal load transfer.

Direct Anterior Approach (DAA) developed by Judet is one of less invasive hip approach. With a stem with straight insertion path, the extended line of proximal femoral axis should come out of the skin. To achieve this position, proximal end of the femur has to be fully pulled up. (Fig.1) Some of the cases would be able to be lifted up but some have difficulty. Using lateral flare stem with curved 3 dimensional insertion path, even the axis extension does not come out of the skin, it would be expected to be inserted. In the present study, 3D insertion path of the lateral flare short stem for DAA was analyzed.

Materials and methods

Preoperative CAT scan data were transferred to STL data by Mimics®. The procedures after that were done by Magics®. First, neck osteotomy was done, externally rotated, and mild extension that doesn't make the axis come out of the skin was added. Then insertion path was verified keeping the stem attached medial sidewall of the canal (Fig. 2). In actual case, skin translation and pelvis rotation was assessed by 3D scanner. (Fig. 3)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 57 - 57
1 Jan 2016
Iguchi H Mitsui H Murakami S Kobayashi M Nagaya Y Nozaki M Goto H Watanabe N Shibata Y Shibata Y Fukui T Otsuka T
Full Access

Introduction

During THA in lateral position, keeping accurate lateral position is very important for obtaining good cup position. We normally use two kinds of hip positioner, but sometimes we can only use universal positioner provided with operational table. The pelvic tilt can be changed by surgical procedures such as traction, dislocation, reduction and so forth. In the present study, pre-op and post-op pelvic tilt was assessed using Kinect (Xbox 360′s sensor) as 3D scanner.

Materials and Methods

As a 3D scanner, “Kinect®” was used (Fig. 1) with scanning software “Artec Studio 9 ®”. First, accuracy of the scanning system was validated, then 6 postero-lateral approach hip replacement with lateral position surgery cases (Fig.2) (1 male and 5 female, average 55.5 y.o., average BMI 27.6, IMP® positioner: 3 cases, Kyocera positioner: 2 cases, universal fixator provided with surgical table: 1 case), one direct anterior approach case, and one supine antero lateral case (Fig. 3) were scanned pre and post operatively. Pelvic tilts were assessed using tableside rails or edges of positioner that is tightly fixed to the table, as the reference.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 117 - 117
1 Jan 2016
Kobayashi M Nagaya Y Goto H Nozaki M Mitsui H Iguchi H Otsuka T
Full Access

Introduction

Patient specific surgical guide (PSSG) is a relatively new technique for accurate total knee arthroplasty (TKA), and there are many reports supporting PSSG can reduce the rate of outlier in the coronal plane. We began to use PSSG provided by Biomet (Signature®) and have reported the same results. Before using Signature, we performed TKA by modified gap technique (parallel cut technique) to get the well balanced flexion gap. Signature is the one of the measured resection technique using the anatomical landmarks as reference points on the images of CT or MR taken before surgery. We usually measure the center gap width and gap balance during operation with the special device “knee balancer”(Fig. 1) that can be used on patella reposition. After cutting all of the bone with Signature, gap balance in the extension position was very good but the gap balance was shown slight lateral opening in the 90 degrees flexion position. So we have changed the surgical procedure. We use Signature for cutting only distal femur and proximal tibia to get extension gap and apply the modified gap technique to decide the rotation of the femoral component (Signature with modified gap technique).

The purpose of this study is to compare the gap balance between the two techniques.

Materials & Methods

From November, 2012 through March, 2014, 50 CR type TKA (Vanguard Knee®, Biomet) in osteoarthritis patients were performed using Signature. 25 TKA were performed using only Signature (group S) and other 25 TKA were done using Signature with modified gap technique (group SG). After all osteotomies of femur and tibia were completed, applying femoral trial, center gap width and gap balance (plus means lateral opening angle) were measured using knee balancer with respect to 30 degrees of the knee flexion angle from zero to 120 degrees (Fig. 2).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 53 - 53
1 Jan 2016
Iguchi H Ida R Murakami S Mitsui H
Full Access

Introduction

Biomechanists have been trying to obtain integrated and accurate human motion data. However, it is not so easy, because some have limitation of accuracy, some have limitation of the observation area, and some are expensive.

For example, motion capturing can obtain whole body motion data, but needs space, is expensive, but only surface motion could be obtained. So is not so sensitive for the bone rotation. Sensors of pressure, acceleration, and so forth are less expensive and less hard to use, but the data are limited. 2D–3D shape matching such as Jointtrack can describe bone motion including rotation, but the detectable area is limited by the size of flat panel fluoroscopy.

In this study, we have combined multiple joint motion analysis by Jointtrack and reconstructed full lower extremities' motion.

Method

Pelvis, bilateral femurs, and bilateral tibiae geometries were obtained from CAT scan using Mimics®. Gait motion fluoroscopy was done on a treadmill around hip joints and knee joints (Fig.1). On each heal thin film switch was attached and connected to electrically driven metal flag which can be recorded in fluoroscopic images on heal strikes. Images of five gait cycles were taken with 15Hz and every image was sorted by the percentage of gait cycle, and then processed by Jointtrack. Centre of femoral head of observing side was defined as our origin. Using treadmill, the walking direction could be uniquely defined. From the femoral 3D displacement and rotation, knee position can be calculated. The same procedures were done for the knee assessment, mutual coordinate of hip centre from the knee can be calculated. All of them are sorted by the percentage of the gait cycle too. Combining data from hip and knee, complete lower extremities' motion could be described. Regression analyses of x, y, z coordinates of femurs from hip and from knee were done to evaluate the accuracy.

Motion capture of floor gait and treadmill gait were done to evaluate the difference. (Fig.2)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 55 - 55
1 Jan 2016
Iguchi H Mitsui H Murakami S Kobayashi M Nagaya Y Nozaki M Goto H Watanabe N Shibata Y Shibata Y Fukui T Otsuka T
Full Access

Introduction

In THA of DDH cases, sometimes shortening and/or derotational subtrochanteric osteotomy is required, for cases with high hip center and/or high anteversion. Initial fixation is one of the most important problems after subtrochanteric osteotomy. To prevent rotational displacement V-osteotomy or step osteotomy is often used. Even though until the osteotomy part unites, additional fixation is required. When a stem with distal load transfer was used body weight can be transferred to healthy part, so early full weight bearing should be expected. However, the muscles around hip joint can pull up proximal part, so it would be possible osteotomy part to be split. When a stem with proximal load transfer, body weight would be loaded on non united osteotomy part. So full weight bearing could sometimes be postponed. A stem that has both proximal and distal load transfer, and has facility for prevent rotation, those situations would possibly be simply solved.

Lima (Italy) has a proximal load transfer conical stem with fins “Modulus” and a distal load transfer conical stem “Revision.” Combining these two stems, a stem as explained prior was designed. In the present study, applicability of the stem for cases such as subtrochanteric osteotomy was assessed.

Materials and Methods

The stem geometry data were provided by the maker. Forty CAT scan DICOM data, 12 male, 28 female, 58+/−13.8 Y.O. were transferred to STL geometry data using Mimics®. Then using Magics® fit studies were done. For each femur, most suitable size of conventional “Modulus” and double conical stem “Modulus R” were selected to have tight fit making greater trochanter top height as head center height, then the area where stem core attaches to the inside surface of the canal were determined.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 41 - 41
1 Jan 2016
Mitsui H Sugimoto K Sakamoto M
Full Access

Between April 2008 and February 2012, we implanted 159 large-diameter MOM stemmed THA with head diameters of 38–50mm. There were 6–38mm, 22–40mm, 42–42mm, 42–44mm, 24–46mm, 13–48mm, 4–50mm, 5–52mm, and one-54mm heads implanted in 138 patients (21 males and 117 females). The pre-operative diagnoses included: 120 OAs, 12 IONs, 4 femoral neck fractures, one RA, and one post-traumatic OA. Their ages were 40–86 years (avg. 63.6 yrs). Follow up was 4 to 67 months post implantation (avg. 40.4 months). All implants were manufactured by one company (Wright Medical Technology, Arlington, TN, USA). The stems were of a standard titanium-aluminum alloy, either 44 ANCA-FIT or 115 PROFEMUR Z non-cemented stems. Acetabular components were all CONSERVE PLUS cobalt-chromium monoblock shells. Heads were also fabricated out of cobalt-chromium alloy, with modular junctions. Patients with complaints of groin pain and/or swelling or hip instability underwent MRI examination in order to detect the presence of fluid collections or soft tissue masses. The statistical correlation between abnormal findings on MRI and age, gender, head diameter, component position and duration post-surgery was performed.

35 hips in 31 patients (22.0%) were found to have either a fluid collection or “pseudotumor” on MRI. These were in 5 males and 26 female patients. According to Hart's MRI classification, they were classified 21 hips in Type 1, twelve hips in Type 2, and two hips in Type 3 (Fig. 1, 2 and 3). 8 hips in 8 patients who had any pseudotumors were undergone revision THA (Fig. 4, 5 and 6). All hips had corrosions at head-neck taper junctions (Fig. 7). There was no difference in age between these two groups of patients (63.7 vs. 63.6 yrs.), but a significant difference in duration from the time of implantation of two groups (23.9 vs. 44.8 months). There appeared to be no significant difference between the mean head diameter of the two groups, 43.2mm and 44.0mm respectively. There was no statistical difference between the two groups with regard to implant orientation: cup inclination 18–70 degrees (41.8 vs. 43.6 degrees); cup anteversion −13–49 degrees (15.1 vs. 14.7 degrees); stem anteversion 2–48 degrees (20.1 vs. 23.3 degrees); and stem offset 17.5–56.2mm (38.2 vs. 37.8mm). Furthermore, according to Lewinnek's safe zone, there was no difference in cup orientation between the two groups (Fig. 8). When we investigated the types of modular neck, the hips having any pesudotumors tended to have long or varus necks.

In this study, it is important to emphasize that the appearance of symptoms and development of a pseudotumor occurred early after a MOM THA in some patients. Also it will be important to subject all patients to MRI examination to evaluate the possibility of “silent” fluid collections and pseudotumors. In large-diameter head metal-on-metal stemmed THAs, femoral stems having long or varus neck may contribute to head-neck junction failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 430 - 430
1 Dec 2013
Mitsui H Sugimoto K Sakamoto M
Full Access

[Introduction]

In 1995, Muller reported on the improvement of metal-on-metal (MOM) bearing over the existing metal-on-polyethylene (MOP) articulations which demonstrated more rapid wear together with granulomatous foreign body reactions, damage of periarticular bony and soft tissues and associated expansile psoas bursal masses. He suggested that adequate lubrication together with improved material properties and manufacturing technologies would bring to the market a superior device with greater longevity. We wish to present our experience with a modern version of a MOM bearing.

[Material and Methods]

Between April 2008 and February 2012, we implanted 160 MOM THA with head diameters of 38–50 mm in 139 patients (21 males and 118 females). Their ages were 40–86 years (avg. 63.6 yrs). Follow up was 9 to 53 months post implantation (avg. 28 months). All implants were manufactured by one company (Wright Medical Technology, Arlington, TN, USA). The stems were of a standard titanium-aluminum alloy, either 45 ANCA-FIT or 115 PROFEMUR Z non-cemented stems. Acetabular components were all CONSERVE PLUS cobalt-chromium monoblock shells. Heads were also fabricated out of cobalt-chromium alloy, with modular junctions. Patients with complaints of groin pain and/or swelling or hip instability underwent MRI examination in order to detect the presence of fluid collections or soft tissue masses (Fig. 1 and 2). The statistical correlation between abnormal findings on MRI and age, gender, head diameter, component position and duration post-surgery was performed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 533 - 533
1 Dec 2013
Shibata Y Iguchi H Murakami S Mitsui H
Full Access

Background:

For hip prostheses, short stems allow easy insertion and reduce thigh pain risk, and are therefore suitable for Minimally Invasive Surgery. However, clinical outcome depends on sufficient initial fixation in the proximal femoral component. Revelation stems are designed to increase medullary cavity occupancy in the proximal femoral component and allow physiological load transmission within this component. Theoretically, on initial fixation of the proximal part of the stem, fixation remains unaffected by cutting the distal part of the stem. Recently, the Revelation micro MAX stem has become available. In this system, only the distal part of the stem is removed. To prepare for the introduction of this stem, we evaluated its rotational stability by installing it in the femurs of formalin-fixed cadavers. We then evaluated the time course of changes in bone density at the stem circumference and stem position by CT in the first eight patients undergoing hip arthroplasty.

Subjects and Methods:

Micro MAX stems were inserted into the left femurs of one male and six female cadavers (76 to 95 years of age). A commonly used torque meter was mounted on the stem, and stem fixation was evaluated by the application of clockwise torque of 6 to 12 N-m. Further, in patients, three men and five women (age range 38–83 years, mean 67 years; two cases of femoral head necrosis, two of femoral neck fracture, and four of osteoarthritis of the hip) who underwent surgery with the micro MAX stem from July 2012 to April 2013 were evaluated at 3 weeks, and 3 and 6 months after surgery for stem insertion angle and stem subsidence by CT, and for bone density around the stem by the DEXE method.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 81 - 81
1 Dec 2013
Iguchi H Mitsui H Murakami S Watanabe N Tawada K Nozaki M Goto H Kobayashi M Otsuka T
Full Access

Introduction

We have been developed lateral flare stem and have been using it since 1989. It was custom stem at first. After being experienced, using the same software, off-the-shelf version lateral flare stem (Revelation) was developed in 1996 in the U.S. We could start using it since 2001 in our country. Lateral flare stems are designed to reproduce physiological proximal load transfer lateral side as well as medial side. It was obtained by having bigger and more accurate proximal part with lateral flare. The design is optimized by matching with 3D insertion path.

Using many custom stems including different length and off-the-shelf standard stems, we have come to feel that as for this high proximal fit and load transfer design, it is not necessary to having long distal part and sometimes it is harmful to obtain good proximal load transfer in some situation such as type A (champagne flute) canal. So we have developed short version of the stem. Many makes of the hip stems have included short stems recently. Some aimed to improve easier insertion, some aimed to improve the volume of residual bone quantity. We have aimed to improve proximal fit expecting more proximal and more physiological load transfer to the femur.

Objectives

Our objectives are to comare standard stem and short stem from biomechanical aspect and clinical aspect.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 439 - 439
1 Dec 2013
Murakami S Iguchi H Kobayashi M Mitsui H Otsuka T
Full Access

Introduction:

Obesity is one of the biggest issues to harm health so as increase medical costs worldwide. Unfortunately, Japan is no exception. Under a big governmental campaign, obese rate in Japanese elderly begins to decrease very recently. However, we cannot help to have impression that our patients who undergo hip/knee replacement surgery have been getting heavier and heavier. The purpose of this study is to examine the change of body mass in our patients and find related factors.

Patients and methods:

We reviewed hospital record of patients who underwent knee or hip replacement from January 1 to December 31 in 2004 or 2012. Patient who underwent either unicompartmental or total knee arthroplasty was included, however, those who went through femoral head replacement (hemiarthroplasty) was excluded from this study population. Body mass index (BMI) was calculated from body height and weight measured within a week before surgery. Unlike in United States, BMI greater than 25 is categorized as obese, and below 18.5 is considered underweight in Japan. Additionally, gender, age at surgery, operated site (hip or knee), primary surgery or revision, blood loss in operation, surgery time, anesthesia time were evaluated as co-factors.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 431 - 431
1 Dec 2013
Mitsui H Iguchi H Tawada K Watanabe N Nozaki M Goto H Nagaya Y Kobayashi M Otsuka T
Full Access

This study shows the radiographic results of total hip arthroplasty (THA) using Revelation stem ® (Djo surgical USA) for hip joint disease.

We removed cases which we couldn't follow up, the remaining of the patients who had undergone a primary THA July 2007 to December 2009 in our institution using Revelation hip stem® and 58 cases-65 hips (14 men and 44 women) were possible for progress observation on this study, and radiographic evaluation was done at the time of the last observation. The preoperative diagnosis of the hip included osteoarthritis (OA) in 40 patients, idiopatic, necrosis of the hip in 13 patients, Rheumatoid arthritis (RA) in 4 patients, and femoral head fracture in 1 patient.

Three patients had undergone femoral head replacement (FHA) and 55 patients had undergone THA.

At the time of the last evaluation, spot welds were detected in 63 hips (97%) in zone1 and 7. Demarcation lines, which indicates movement of the stem, were detected in zone3,4,5, but not in the proximal of the stem.

Stress shielding were observed in 32 joints, according to Engh's classification, first degree were 27 joints and second degree were 5 joints. Cortical hypertrophy were detected in 13 joints.

The revelation stem features a lateral overhang structure (lateral flare) and the stem has an expanded proximal geometry allowing the device to rest on both medial and lateral cortices at the metaphyseal level. Above all the stem has anterior overhand structure (trapezoidal structure). The medullary cavity occupation rate is made to increase by these structures. Above all, the stability of the stem is increased by a proximal portion by three point support.

The distal stem is tapered and polished, which prevents the stress loading to a distal portion of the device.

Stress shielding more than the third degree is not detected, and spots welds were detected in the proximal of the stem. These facts indicate that the concept of this stem, transmit loading to the femur bone, at the proximal portion of the stem, would be achieved.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 82 - 82
1 Dec 2013
Iguchi H Mitsui H Murakami S Watanabe N Tawada K Nozaki M Kobayashi M Otsuka T
Full Access

Introduction

Massive defect of the acetabular bone is one of the severe situation in the hip arthroplasty. Installation of cup supporter or acetabular reinforcement device is one of the important method as well as big cup and bone graft etc. Preparing the device to be suitable shape is very important and installing it at the very position where the shaping was intended is also very important to obtain a stable condition for the arthroplasty. When we use navigation system, the device must be programmed in. But it is impossible to programme a device we have bended by ourselves into the system. If we can use a navigation system for such devices for those cases, we can expect better installation. We can fit the device on the patient's bone during the surgery of course; which is the ordinary procedure fot it; but it requires much time and tissue damage maybe with less accurate fitting.

Materials and Methods

Two primary and three revision total hip arthroplasty cases with severe acetabular bone defect were treated with this method. First we have made chemical wood model for each case and bended the cup supporter on it. (Fig. 1) Then CAT scan of the model and the bended device on it were taken. Then the coordinate system of DICOM data set of the patient's original pelvis and the second DICOM data set i.e. the bended prosthesis were unified using MIMICS (Materialize, Belgium.) An STL format geometry data file of the bended device was extracted and merged into original DICOM dataset. Thus we could obtain a DICOM data set we call “predicted post-op DICOM.” During the surgery, a navigation system was used based on the predicted DICOM data.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 264 - 264
1 Mar 2013
Mitsui H Iguchi H Kobayashi M Nagaya Y Goto H Nozaki M Watanabe N Murakami S Otsuka T
Full Access

INTRODUCTION

In total hip arthroplasty, preoperative planning is almost indispensable. Moreover, 3-dimensional preoperative planning became popular recently. Anteversion management is one of the most important factors in preoperative planning to prevent dislocation and to obtain better function.

In arthritic hip patients osteophytes are often seen on both femoral head and acetabulum. Especially on femoral head, osteophytes are often seen at posterior side and its surface creates smooth round contour that assumes new joint surface. (Fig. 1). We can imagine new femoral head center tracing that new joint surface.

OBJECTIVES

In the present study, the posterior osteophytes are compared in osteoarthritic patients and other patients.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 263 - 263
1 Mar 2013
Mitsui H Sugimoto K Nishino K
Full Access

Introduction

Pseudotumor is a known complication of Metal-on-Metal (MOM) total hip arthroplasty (THA). MRI is usually used to visualize pseudotumor formation. However, small pseudotumors close to the THA components may not be observed using MRI due to image distortion by the interaction between the metallic objects and the magnetic fields. The CT image quality also degrades because MOM THA components can induce X-ray beam-hardening effects. Therefore, we evaluated contrast-enhanced (CE) tomosynthesis. Tomosynthesis is known as an X-ray tomography technique that provides images with fewer metal artifacts and lower X-ray doses for the patients. The aim of this report was to investigate the detectability of pseudotumors by tomosynthesis.

Case Report

A 71-year-old woman had undergone unilateral cementless large-diameter MOM THA using a couple of Conserve Plus acetabular cup and Profemur Z femoral component (Wright Medical, Memphis, Tennessee) for primary arthritis of the left hip at our hospital. She presented with severe hip, groin and buttock pain and swelling at fifteen months after surgery. Therefore, she was examined MRI and tomosynthesis using Sonialvision-Safire X-ray Radiography/Fluoroscopy System (Shimadzu Corporation, Japan). Plain tomosynthesis was obtained before the contrast media injection and followed by CE-tomosynthesis. Then, subtraction tomosynthesis between plain and CE-tomosynthesis were calculated in order to increase the image contrast. The subtraction tomosynthesis image enhanced the pseudotumor visibility, which was considered to be equal to that depicted using MRI (Fig. 1 and 2). However, using MRI, cystic lesions in the pseudotumor appeared as a very high signal in the T2 weighted images, whereas CE-tomosynthesis resulted in no image contrast (Fig. 3). The tomosynthesis image resulted in less image distortion and fewer metal artifacts than MRI, even in the area close to the hip implants.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 344 - 344
1 Mar 2013
Sugimoto K Mitsui H Minoda Y Nishino K
Full Access

Frontal and lateral plain radiographs are the first choice for follow-up observations of the osteotomy boundary that faces the femoral and tibial components of a TKA. However, as plain radiographs provide no information in the image depth direction, it is difficult to determine the exact position of early-stage bone radiolucent lines. A new tomosynthesis technique, which uses both iterative reconstruction and metal extraction methods, has recently attracted attention. We report that this technique provides multi-slice images of the boundary between the metallic implant and the osteotomy surface, which is difficult to observe using conventional multi-slice imaging methods such as CT and MRI, and permits semi-three-dimensional evaluations of polyethylene wear.