header advert
Results 1 - 46 of 46
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 22 - 22
2 May 2024
Logishetty K Whitwell D Palmer A Gundle R Gibbons M Taylor A Kendrick B
Full Access

There is a paucity of data available for the use of Total Femoral Arthroplasty (TFA) for joint reconstruction in the non-oncological setting. The aim of this study was to evaluate TFA outcomes with minimum 5-year follow-up.

This was a retrospective database study of TFAs performed at a UK tertiary referral revision arthroplasty unit. Inclusion criteria were patients undergoing TFA for non-oncological indications. We report demographics, indications for TFA, implant survivorship, clinical outcomes, and indications for re-operation.

A total of 39 TFAs were performed in 38 patients between 2015–2018 (median age 68 years, IQR 17, range 46–86), with 5.3 years’ (IQR 1.2, 4.1–18.8) follow-up; 3 patients had died. The most common indication (30/39, 77%) for TFA was periprosthetic joint infection (PJI) or fracture-related infection (FRI); and 23/39 (59%) had a prior periprosthetic fracture (PPF). TFA was performed with dual-mobility or constrained cups in 31/39 (79%) patients. Within the cohort, 12 TFAs (31%) required subsequent revision surgery: infection (7 TFAs, 18%) and instability (5 TFAs, 13%) were the most common indications. 90% of patients were ambulatory post-TFA; 2 patients required disarticulation due to recurrent PJI. While 31/39 (79%) were infection free at last follow-up, the remainder required long-term suppressive antibiotics.

This is the largest series of TFA for non-oncological indications. Though TFA has inherent risks of instability and infection, most patients are ambulant after surgery. Patients should be counselled on the risk of life-long antibiotics, or disarticulation when TFA fails.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1148 - 1156
1 Sep 2018
Ferguson RJ Broomfield JA Malak TT Palmer AJR Whitwell D Kendrick B Taylor A Glyn-Jones S

Aims

The aim of this study was to determine the stability of a new short femoral stem compared with a conventional femoral stem in patients undergoing cementless total hip arthroplasty (THA), in a prospective randomized controlled trial using radiostereometric analysis (RSA).

Patients and Methods

A total of 53 patients were randomized to receive cementless THA with either a short femoral stem (MiniHip, 26 patients, mean age: 52 years, nine male) or a conventional length femoral stem (MetaFix, 23 patients, mean age: 53 years, 11 male). All patients received the same cementless acetabular component. Two-year follow-up was available on 38 patients. Stability was assessed through migration and dynamically inducible micromotion. Radiographs for RSA were taken postoperatively and at three, six, 12, 18, and 24 months.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1146 - 1147
1 Sep 2018
Ferguson RJ Broomfield JA Malak TT Palmer AJR Whitwell D Kendrick B Taylor A Glyn-Jones S


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 37 - 37
1 May 2018
Ferguson R Broomfield J Malak T Palmer A Whitwell D Taylor A Glyn-Jones S
Full Access

Background

Short bone-conserving femoral stem implants were developed to achieve more physiological, proximal bone loading than conventional femoral stems. Concerns have arisen, however, that improved loading may be offset by lower primary stability because of the reduced potential area for bony contact.

Aims

The aim of this study was to determine the primary stability of a novel short femoral stem compared with a conventional femoral stem following cementless total hip arthroplasty (THA), in a prospective, blinded, randomised, controlled trial using radiostereometric analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 11 - 11
1 May 2018
Alvand A Grammatopoulos G Quiney F Taylor A Whitwell D Price A Dodd C Jackson W Gibbons M
Full Access

Endoprosthetic replacement (EPR) is an available option for the management of massive bone loss around failed knee implants. The aim of this study was to determine the results of knee EPRs performed for non-tumour indications. Since 2007, 85 EPRs were performed for in a single tertiary centre by seven surgeons. Mean age at surgery was 73.5 years (range:35–95) with infection as the most common indication (49%), followed by aseptic loosening (18%), complex primary replacement (16%), fracture (15%) and mechanical failure (2%). Mean follow up was 4 years (range:1–9). Functional outcome was determined using the Oxford Knee Score (OKS). At follow-up, 21 patients were deceased and 2 lost to follow-up. Complication rate was 19%. Of the 7 infected cases, 6 were treated with DAIR (debridement, antibiotics, and implant retention) and one underwent above knee amputation. Four of the patients undergoing DAIR were cleared of infection and 2 are on long-term antibiotics. Accounting for implant revision, loss to follow-up and those on long-term antibiotics as failures, 5-year survival was 89% with an average OKS of 25 (SD=10). This mid-term study shows that distal femur EPR is a valuable option for the increasing burden of complex revision knee surgery


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 4 - 4
1 Dec 2016
Alvand A Grammatopoulos G de Vos F Scarborough M Athanasou N Kendrick B Price A Gundle R Whitwell D Jackson W Taylor A Gibbons M
Full Access

Introduction

The burden of peri-prosthetic joint infection (PJI) following hip and knee surgery is increasing. Endoprosthetic replacement (EPR) is an option for management of massive bone loss resulting from infection around failed lower limb implants.

Aims

To determine clinical outcome of EPRs for treatment of PJI around the hip and knee joint.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1463 - 1470
1 Nov 2016
Grammatopoulos G Alvand A Martin H Whitwell D Taylor A Gibbons CLMH

Objectives

A possible solution for the management of proximal femoral bone loss is a modular femoral endoprosthesis (EPR). Although the outcome of EPRs in tumour surgery has been well described, the outcome of their use in revision hip surgery has received less attention. The aim of this study was to describe the outcome of using EPR for non-neoplastic indications.

Methods

A retrospective review of 79 patients who underwent 80 EPRs for non-neoplastic indications was performed, including the rates of complication and survival and the mean Oxford Hip Scores (OHS), at a mean of five years post-operatively. The mean age at the time of surgery was 69 years (28 to 93) and the mean number of previous operations on the hip was 2.4 (0 to 17). The most common indications for EPR implantation were periprosthetic joint infection (PJI) (n = 40), periprosthetic fracture (n = 12) and failed osteosynthesis of a proximal femoral fracture or complex trauma (n = 11).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 47 - 47
1 Jun 2016
Grammatopoulos G Alvand A Martin H Taylor A Whitwell D Gibbons M
Full Access

The management of proximal femoral bone loss is a significant challenge in revision hip arthroplasty. A possible solution is the use of a modular proximal femur endoprosthesis (EPR). Although the survivorship and functional outcome of megaprostheses used in tumour surgery has been well described, outcome of EPRs used in revision hip surgery has received less attention. The aim of this study was to determine the 5-year outcome following proximal femur EPR and determine factors that influence it.

This was a retrospective consecutive case series of all EPRs (n=80) performed for non-neoplastic indications, by 6 surgeons, in our tertiary referral centre, between 2005–2014. Patient demographics and relevant clinical details were determined from notes. The most common indications for the use of EPRs included infection (n=40), peri-prosthetic fracture (n=12) and failed osteosynthesis of proximal femoral fractures/complex trauma (n=11). Outcome measures included complication and re-operation rates, implant survival and assessment of functional outcome using the Oxford-Hip-Score (OHS).

The mean age at surgery was 69 years and mean follow-up was 4 (0 – 11) years. The mean number of previous hip operations was 2.4 (range: 0 – 17). Twenty-five patients sustained a complication (31%), the most common being infection (n=9) and dislocation (n=4). By follow-up, further surgery was required in 18 (22%) hips, 9 of which were EPR revisions. 5-yr implant survivorship was 87% (95%CI: 76 – 98%). Mean OHS was 28 (range: 4 – 48). Inferior survival and outcome were seen in EPRs performed for the treatment of infection. Infection eradication was achieved in 34/41 with the index EPR procedure and in 40/41 hips by follow-up.

Limb salvage was achieved in all cases and acceptable complication- and re-operation rates were seen. EPRs for periprosthetic fractures and failed osteosynthesis had best outcome. We recommend the continued use of proximal femur EPR in complex revision surgery.


Bone & Joint Research
Vol. 2, Issue 6 | Pages 96 - 101
1 Jun 2013
Harvie P Whitwell D

Objectives

Guidelines for the management of patients with metastatic bone disease (MBD) have been available to the orthopaedic community for more than a decade, with little improvement in service provision to this increasingly large patient group. Improvements in adjuvant and neo-adjuvant treatments have increased both the number and overall survival of patients living with MBD. As a consequence the incidence of complications of MBD presenting to surgeons has increased and is set to increase further. The British Orthopaedic Oncology Society (BOOS) are to publish more revised detailed guidelines on what represents ‘best practice’ in managing patients with MBD. This article is designed to coincide with and publicise new BOOS guidelines and once again champion the cause of patients with MBD.

Methods

A series of short cases highlight common errors frequently being made in managing patients with MBD despite the availability of guidelines.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 714 - 717
1 May 2013
Yates P Kellett C Huntley JS Whitwell D Reed MR Beadel G Snyckers C

In May 2012, in airports across the globe, seven orthopaedic surgeons bravely said goodbye to their loved ones, and slowly turned towards their respective aircraft. Filled with expectation and mild trepidation they stepped into the unknown… the ABC fellowship of 2012.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 96 - 96
1 Jan 2013
Palmer A Thomas G Whitwell D Taylor A Murray D Price A Arden N Glyn-Jones S
Full Access

Introduction

Hip arthroscopy is a relatively new procedure and evidence to support its use remains limited. Well-designed prospective clinical trials with long-term outcomes are required, but study design requires an understanding of current practice. Our aim was to determine temporal trends in the uptake of non-arthroplasty hip surgery in England between 2001 and 2011.

Methods

Using procedure and diagnosis codes, we interrogated the Hospital Episode Statistics (HES) Database for all hip procedures performed between 2001 and 2011, excluding those relating to arthroplasty, tumour or infection. Osteotomy procedures were also excluded.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 119 - 119
1 Jan 2013
Bayliss L van Drunen G Whitwell D Giele H Gibbons M van de Sande M
Full Access

Segmental excision of long-bone sarcomas can require complex reconstruction, often resulting in the use of prosthetic replacements at a young age.

The use of vascularised free fibula grafting (VFFG) is well established as a reconstruction modality in sarcoma surgery.

Aims

To analyse the experience of two European sarcoma centres and their use of vascularised free fibula grafting as a primary and revision procedure in limb salvage for diaphyseal long-bone defects in sarcoma surgery.

Methods

A retrospective analysis was carried out of 70 consecutive patients undergoing VFFG between 1996 and 2009 under the Oxford Sarcoma Service (Nuffield Orthopaedic Centre) and the Dutch Orthopaedic Tumour Society (Leiden University Hospital). Clinical and radiological assessments were made and functional outcome scores collected.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 120 - 120
1 Jan 2013
Bayliss L Thomas S Whitwell D Giele H Gibbons M
Full Access

Aims

Delays to diagnosis and management of soft tissue sarcomas are preventable but still occur. The introduction of a referral proforma to the Thames Valley Cancer Network in 2005 and National guidelines in 2006 aimed to decrease the incidence of partially and inadequately managed soft tissue sarcomas. This study aims to assess referrals for partially or inadequately managed soft tissue sarcomas and their subsequent management.

Methods

A prospective analysis of all patients referred to the Oxford Sarcoma Service following inadvertent excision of a soft tissue sarcoma between January 2010 and August 2011 was carried out. Pre-operative investigation and subsequent secondary managements were recorded. Patients with a diagnosis of dermatofibrosarcoma protuberans were excluded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 247 - 247
1 Sep 2012
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R Mclardy-Smith P Gill H Murray D
Full Access

Introduction

Since the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA), thousands of such prostheses have been implanted worldwide in younger patients with end-stage hip osteoarthritis. However, no independent centre has reported their medium-to-long term outcome. The aim of this study is to report the ten year survival and outcome of the Birmingham Hip Resurfacing (BHR), the most commonly used MoMHRA worldwide.

Methods

Since 1999, 648 BHRs were implanted in 555 patients, the majority of which were male (326). The mean age at surgery was 52.1years (range: 17–82), with primary OA as most common indication (85%). Mean follow up was 7.1years (range: 1–11). The Oxford Hip Score (OHS) and UCLA questionnaires were sent to all patients. Implant survival was established, with revision as the end point. Sub-analysis was performed by gender, femoral component size (small: <45mm, standard: 46–52, large: >53mm) and age at surgery (young:<50yrs, old:>50yrs).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 35 - 35
1 Jul 2012
Pennant S Gibbons C Whitwell D Ostlere S Morley J
Full Access

Introduction

Tissue diagnosis is essential to direct the definitive management of a suspected soft tissue or bone sarcoma tissue. Knowledge of both the diagnostic yield and accuracy of core needle biopsies is therefore important to give the investigating team information on the likelihood of their initial investigations achieving a diagnosis.

Methods

This is a retrospective study of patients referred to a specialist orthopaedic centre for investigation of a suspected soft tissue or bone sarcoma. Details of all core needle biopsies performed in a 13-month period were obtained from the hospital database. We defined a diagnostic biopsy as either a specific tissue diagnosis or a biopsy that decided the definitive management of the patient, specifically if malignancy was excluded and no further intervention was required, to calculate the diagnostic yield. Diagnostic accuracy was established by comparing histological diagnosis at biopsy to that at final excision.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 24 - 24
1 Jul 2012
Cosker T Whitwell D Sharpley F Porter C Gibbons M
Full Access

Introduction

General Practitioners will be confronted with a sarcoma rarely in their working lives. Most will never see a bone sarcoma although most will see at least one soft tissue sarcoma. Guidelines designed to lead to earlier diagnosis of the most common cancers were introduced by NICE in 2000 and were updated in 2005, containing basic guidance on the earlier diagnosis of bone and soft tissue tumours. Referral criteria include: masses greater than 5cm in diameter, masses deep to fascia, masses which are fixed or immobile, masses which are painful, those which are increasing in size and recurrence after previous excision

Methods

We examined 350 General Practitioner referrals over the past 3 years to our service and examined the correlation between the above criteria and the likelihood of malignancy.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 32 - 32
1 Jul 2012
Cosker T White HB James A Athanisou N Whitwell D Gibbons M
Full Access

Introduction

Primary soft tissue sarcomas of the extremities are uncommon. Many such lesions will present to specialists in other clinics such as specialist Hand or Foot and Ankle clinics. Many are of a small size at presentation and may appear to be alternate, more common pathology.

Methods

We collected data from all those patients with acral soft tissues sarcomas and referred to the Oxford Sarcoma Service, Nuffield Orthopaedic Centre, Oxford over a thirteen year period from 1997 – 2010. Data were collected regarding the primary suspected diagnosis, the final diagnosis, the referral route and whether patients had undergone previous inadvertent excision.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 33 - 33
1 Jul 2012
Cosker T Whitwell D James A Reynolds E Porter C Gibbons M
Full Access

Introduction

A GP may only encounter one sarcoma in their professional career. Early diagnosis and treatment will improve the outcomes of this rare and malignant disease. Guidelines designed to lead to earlier diagnosis of the most common cancers were introduced by NICE in 2000 and were updated in 2005. These advise and assist in the early referral of potential bone and soft tissue sarcoma. Prior to 2000 only ~10% of GP referrals were proven to be malignant.

Methods

In a referral region of ∼3m, we reviewed the referral patterns of suspected sarcoma by General Practitioners since 2005 in an effort to determine whether the published NICE guidelines had influenced an improvement in the diagnosis and management of malignant disease.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 11 - 11
1 Jul 2012
Cosker T MacDonnell S Critchley P Whitwell D Giele H Athanasou N Gibbons M
Full Access

Introduction

Our Unit has been treating large volume soft tissue sarcomas involving the sciatic nerve with epineurectomy for over a decade. The aim of this study was to quantify the functional outcome of patients who were known to have sciatic nerve involvement pre-operatively and went on to have nerve preserving surgery utilising a planned marginal excision with epineurectomy.

Methods

20 patients with soft tissue sarcomas involving the sciatic nerve were studied treated between 1997 and 2010. Nineteen underwent surgery with extended epineurectomy of the sciatic nerve and planned marginal excision. All patients underwent staging and follow up at our Sarcoma Clinic with functional assessment and TESS evaluation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 77 - 77
1 Mar 2012
James AR Dean B Moore E Whitwell D Price A Gibbons C
Full Access

Aim

A case series with functional and radiographic outcomes, of modular endoprosthetic distal femoral replacement in complex cases of periprosthetic fracture.

Method

Sixteen cases were identified of endoprosthetic replacement (EPR) from the bone and soft tissue cancer implant registry. A retrospective review was undertaken.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 546 - 546
1 Nov 2011
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R McLardy-Smith P Murray D Gill H
Full Access

Introduction: Metal-on-metal-hip-resurfacing-arthroplasty (MoMHRA) has been associated with the development of inflammatory pseudotumours(IP), especially in females. IPs have been linked to wear debris, which can be related to metal-ion blood levels. Acetabular component position has been shown to influence wear. We have identified an optimum component orientation minimising IP risk around an inclination/anteversion of 40°/20°±10°. Our aim was to see if this optimal position results in lower metal ions and to identify the boundary of an optimal placement zone for low wear.

Methods: A cohort of 104 patients(60M:44F) with unilateral MoMHRA was studied. Blood tests were obtained at a mean follow up of 3.9 years and serum Co/Cr levels were measured(ICPMS). High metal ion concentrations were defined as Co> 4.1ppb and Cr> 5.2ppb. Radiographic cup inclination/anteversion were measured using EBRA. The differences in ion levels between different orientation zones were investigated. Three orientation zones were defined centered on 40°/20°: Z1-within ±5°, Z2-outside ±5°/within ±10° and Z3-within ±10°.

Results: There was a wide range of cup placements. Females had significantly (p< 0.001) smaller components(mean:51, 44–60) than males(mean: 56, 52–64). Cr levels, but not Co, were higher in females(p=0.002) and those with small femoral components(< 50mm, p =0.03). Patients with cups within Z1 (n=13) had significantly lower Co(p=0.005) and Cr(p=0.001). Males with cups within Z3(n=27) had lower ion levels in comparison to those outside, which were significantly lower for Co(p=0.049) but not Cr(p=0.084). Females had similar ion levels within and out of Z3(Cr/Co: p=0.83/0.84). Co levels were significantly lower in Z1(n=13) in comparison to Z2(n=33)(p=0.048) but Cr levels were not different (p=0.06).

Discussion: MoMHRA cups placed within ±5° of the optimum(40°/20°) had significantly lower metal ions indicating lower wear within this narrow zone. This safe zone, could extend to ±10° for males only. The narrower safe zone coupled with smaller components implanted are possible factors contributing to the increased IP incidence seen in females.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 547 - 547
1 Nov 2011
Thomas G Simpson D Taylor A Whitwell D Gibbons C Gundle R Mclardy-smith P Gill H Glyn-jones S Murray D
Full Access

Introduction: The use of highly cross-linked polyethylene (HXLPE) is now commonplace for total hip arthroplasty, however there is no long-term data to support its use. Hip simulator studies suggest that the wear rate of some types of HXLPE is ten times less than conventional polyethylene (UHMWPE). The outcomes of hip simulator studies are not always reproduced in vivo and there is some evidence that HXLPE wear may increase between 5 and 7 years.

Method: A prospective double blind randomised control trial was conducted using Radiostereometric Analysis (RSA). Fifty-four subjects were randomised to receive hip replacements with either UHMWPE liners or HXLPE liners. All subjects received a cemented CPT stem and uncemented Trilogy acetabular component (Zimmer, Warsaw, IN, USA). The 3D penetration of the head into the socket was determined to a minimum of 7 years.

Results: The total liner penetration was significantly different at 7 years (p=0.005) with values of 0.33 mm (SE 0.05 mm) for the HXLPE group and 0.55 mm (SE 0.05 mm) for the UHMWPE group. The steady state wear rate from 1 year onwards was significantly lower for HXLPE (0.005 mm/yr, SE 0.007 mm/yr) than for UHMWPE (0.037 mm/yr, SE 0.009 mm/yr) (p=0.007). The direction of wear was supero-lateral.

Discussion: We have previously demonstrated that the penetration in the first year is creep-dominated, from one year onwards the majority of penetration is probably due to wear. This study confirms the predictions from hip simulator studies which suggest that the wear rate of this HXLPE approaches that of metal-on-metal and ceramic-on-ceramic articulations. HXLPE may have the potential to reduce the need of revision surgery, due to wear debris induced osteolysis. It may also enable surgeons to use larger couples, thus reducing the risk of impingement and dislocation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 546 - 546
1 Nov 2011
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R McLardy-Smith P Gill H Murray D
Full Access

Introduction: Metal on metal hip resurfacing arthroplasty(MoMHRA) is an alternative option to THR in the treatment of young adults with OA. A recognised MoMHRA complication is the development of an inflammatory pseudotumour(IP). Diagnosis is made with the aid of US and/or MRI. To-date, no radiographic indication of the presence of IP has been identified. Neck thinning is a recognised phenomenon in MoMHRA hips not associated with any adverse clinical events. Its pathogenesis is considered multi-factorial. Our aim was to establish whether excessive neck narrowing is associated with the presence of a pseudotumour.

Methods: Twenty-seven hips (26 patients) with IP confirmed clinically, radiologically, intra-operatively and histologically were matched for sex, age, pre-operative diagnosis, component size and follow-up with an asymptomatic MoMHRA cohort (Control n=60). For all patients, prosthesis-neck-ratio(PNR) was measured on plain AP pelvic radiographs post-operatively and at follow-up as previously described and validated.

Results: All IP patients (4M:23F) and all (12M:48F) but two controls had a posterior approach at the time of MoMHRA. Post-operatively, there was no difference in the PNR between the two groups (p=0.19). At an average follow up of 3.5 years (range:0.7–8.3), IP patients(mean 1.26, 1.10–1.79) had a significantly higher (p< 0.0001) PNR in comparison to their controls(mean 1.14, 1.03–1.35). Greater neck narrowing occurred in both genders. IP necks had narrowed by an average of 8% (range:3–23). The degree of neck narrowing was correlated with length of survival of implant (p=0.001).

Discussion: This study shows a strong association between IP and neck narrowing. Processes such as impingement and increased wear are considered to be involved in the pathogenesis of both IP and neck narrowing. Furthermore, the presence of an IP, could lead to altered vascularity via a mass effect and further contribute to neck narrowing. Neck narrowing in symptomatic MOMHRA patients should alert surgeons of the possible presence of IP.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 298 - 298
1 Jul 2011
Glyn-Jones S Pandit H Doll H McLardy-Smith P Gundle R Gibbons M Athanasou N Ostlere S Whitwell D Taylor A Gill R Murray D
Full Access

Metal on metal hip resurfacing (MMHR) is a popular procedure for the treatment of osteoarthritis in young patients. Several centres have observed masses, arising from around these devices, we call these inflammatory pseudotumours. They are locally invasive and may cause massive soft tissue destruction. The aim of this study was to determine the incidence and risk factors for pseudotumours that are serious enough to require revision surgery.

In out unit, 1,419 MMHRs were performed between June 1999 and November 2008. All revisions were identified, including all cases revised for pseudotumour. Pseudotumour diagnosis was made by histological examination of samples from revision. A Kaplan-Meier survival analysis was performed, Cox regression analysis was used to estimate the independent effects of different factors.

The revision rate for pseudotumour increased with time and was 4% (95% CI: 2.2% to 5.8%) at eight years. Female gender was a strong risk factor: at eight years the revision rate for pseudotumours in men was 0.5% (95% CI 0% to 1.1%), in women over 40 it was 6% (95% CI 2.3% to 10.1%) and in women under 40 it was 25% (95% CI 7.3% to 42.9%) (p< 0.001). Other factors associated with an increase in revision rate were, small components (p=0.003) and dysplasia (p=0.019), whereas implant type was not (p=0.156).

We recommend that resurfacings are undertaken with caution in women, especially those younger than 40 years of age, but they remain a good option in men. Further work is required to understand the patho-aetiology of pseudotumours so that this severe complication can be avoided.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 315 - 315
1 Jul 2011
James A Dean B Matthews J Price A Stubbs D Whitwell D Gibbons M
Full Access

Introduction: Although originally designed to aid the management of primary malignant bone tumours, the indications for modular endoprosthetic replacement (EPR) have expanded to include complex periprosthetic fractures and failed internal fixation. The incidence of these challenging cases is increasing with an aged population. We reviewed retrospectively our experience with the use of EPR in patients who had undergone limb salvage following complex trauma presentations.

Methods: Between 2003 and 2008 twenty one patients presented with complex trauma related problems and underwent EPR at a specialist tertiary referral centre. The mean age was 71 years (range 44–87) and the median number of previous surgical procedures was 3 (range 0–11). Eight patients presented following failed internal fixation of proximal femoral fractures. Nine patients had periprosthetic fractures around joint arthroplasties, seven relating to total knee replacements (TKRs) and two to total hip replacements (THRs). One case of periprosthetic fracture around THR had undergone failed internal fixation. Two patients had distal femoral fractures, of which one was infected and had undergone failed internal fixation, while the other was unrecon-structable. Two patients had proximal tibia fractures which had both undergone failed internal fixation.

Results: The mean Harris Hip Score was 89.5 (range 64–85) at a mean follow up period of 8 months (minimum 4 months). The mean American Knee Society Score was 82 (range 62–100) and the mean functional score was 62 (range 30–75) at a mean follow up period of 6 months (minimum 2 months). Complications included two cases of deep infection; one resulted in a two stage revision procedure, while the other retained the EPR following a washout.

Discussion: Modular EPR in the lower limb is a durable reconstructive option in complex trauma problems, particularly in the elderly and those patients with significant bone loss. Preliminary functional results indicate very satisfactory results.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 223 - 223
1 May 2011
Grammatopoulos G Langton D Kwon Y Pandit H Gundle R Mclardy-Smith P Whitwell D Murray D Gill H
Full Access

Introduction: The development of Inflammatory Pseudotumour (IP) is a recognised complication following Metal on Metal Hip Resurfacing Arthroplasty (MoMHRA), thought to occur secondary to wear and elevated ion levels. Studies have shown that acetabular component orientation influences the wear of metal-on-metal hip replacement bearings. The aims of this study were to investigate the significance of cup orientation in the development of IP, and to identify a ‘safe-zone’ for cup placement with lower-risk for IP development.

Methods: Twenty six patients (n=27 hips) with IP confirmed radiologically, intra-operatively and histologically were matched for sex, age, pre-operative diagnosis, component size and follow-up with a cohort of asymptomatic MoMHRA patients (Control n=58). Radiographic acetabular anteversion and inclination were measured using EBRA. We calculated the distance in degree space of each acetabular component from the optimum position of 40° inclination and 20° anteversion, recommended by the designers, and thus compared acetabular component position between the two groups. Three different zones were tested as possibly optimum for acetabular placement. These were Lewinneck’s Zone (LZ) (inclination/anteversion; 30–50°/5–25°), and two zones defined by ±5° (Zone 1) or ± 10° (Zone 2) about the suggested target of 40°/20°. An optimal placement zone was determined based on a significant difference in IP incidence between components in the zone versus those outside.

Results: There was a wide range in cup orientations; mean inclination and anteversion were similar in the two groups: IP 47.5° (10.1°–80.6°)/14.1° (4.1°–33.6°) Vs Control 46.1° (28.8°–59.8°)/15.6° (4.3°–32.9°). Acetabular components in the IP group were significantly further away from the optimum position of 40°/20° in comparison to the controls (p=0.023). There was no difference in IP incidence between cups positioned within (IP:13/27, Control:35/58) or out of LZ (p=0.09) and within (IP: 2/27, Control: 10/58) or out of Zone 1 (p=0.156). Cups placed in Zone 2 (IP:6/27, Control:27/58) had significantly lower IP incidence versus those outside this zone (p=0.01). The odd’s ratio of developing IP when the cup is positioned out-of Zone 2 was 3.7.

Discussion: This study highlights the importance of ace-tabular component orientation in IP development. On the whole, patients with pseudotumour had acetabular components that were further away from the optimum position in comparison to the controls. However, a small number of IP patients had well-placed components implying that additional factors, possibly patient and/or gender specific, are involved in the development of pseudotumour. Furthermore, we defined an optimum, ‘safe-zone’ of ±10° around the cup position of 40°/20°. Patients with acetabular components outside this safe zone have an increased risk of IP development.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 135 - 135
1 May 2011
Dean B Matthews J Price A Stubbs D Whitwell D Gibbons C
Full Access

Introduction: Although originally designed to aid the management of primary malignant bone tumours, the indications for modular endoprosthetic replacement (EPR) have expanded to include complex periprosthetic fractures and failed internal fixation. The objective of this study was to evaluate the success of endoprosthetic replacement (EPR) in patients who had undergone limb salvage following complex trauma presentations.

Materials and Methods: Between 2003 and 2008 twenty one patients presented with complex trauma related problems and underwent EPR at a specialist tertiary referral centre. The mean age was 71 years (range 44–87) and the median number of previous surgical procedures was 3 (range 0–11). Eight patients presented following failed internal fixation of proximal femoral fractures. Nine patients had periprosthetic fractures around joint arthroplasties, seven relating to total knee replacements (TKRs) and two to total hip replacements (THRs). One case of periprosthetic fracture around THR had undergone failed internal fixation. Two patients had distal femoral fractures, of which one was infected and had undergone failed internal fixation, while the other was unreconstruc-table. Two patients had proximal tibia fractures which had both undergone failed internal fixation.

Results: The mean Harris Hip Score was 89.5 (range 64–85) at a mean follow up period of 8 months (minimum 4 months). The mean American Knee Society Score was 82 (range 62–100) and the mean functional score was 62 (range 30–75) at a mean follow up period of 6 months (minimum 2 months). Complications included two cases of deep infection; one resulted in a two stage revision procedure, while the other retained the EPR following a washout.

Conclusion: Modular EPR in the lower limb is a durable reconstructive option in complex trauma problems, particularly in the elderly and those patients with significant bone loss. Preliminary functional results indicate very satisfactory results.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 172 - 172
1 May 2011
Gill H Grammatopoulos G Pandit H Glyn-Jones S Whitwell D Mclardy-Smith P Taylor A Gundle R Murray D
Full Access

Introduction: Metal-on-metal hip resurfacing arthroplasty (MoMHRA) has gained popularity as an alternative to THR for younger patients with osteoarthritis. A growing concern has been the association of MoMHRA with the development of inflammatory pseudotumours (IP), especially in women. These have been linked to metal-on-metal wear, which can be related to metal ion concentrations. Elevated metal wear debris levels may result from impingement, rim contact and edge loading. Head-neck ratio (HNR) is a predetermining factor for range of movement and impingement. Neck thinning is a recognised phenomenon post-MoMHRA and we have found an association of IP with increased neck thinning based on a case control study. Our aims were to identify HNR changes a hip undergoes when resurfaced and at follow up; and whether greater neck thinning at follow-up could be associated with the presence of elevated metal ions.

Methods: A cohort of 91 patients (57M:34F) with unilateral MoMHRAs were included in this study. Blood tests were obtained at a mean follow up of 3.9 years (range 1.7–7 years) and serum (Co:Cr) ion levels were measured (ICPMS). High metal ion concentrations were defined as Co> 4.1ppb and Cr> 5.2ppb. For all patients, head-neck ratio (HNR) was measured on plain anterio-posterior pelvic radiographs pre-operatively, immediately post-operatively and at follow-up.

Results: Female patients had significantly bigger HNR pre-op (mean=1.35, range:1.22–1.64) compared to males(mean=1.22, range:1.05–1.38) (p< 0.01). Immediately post-op, female HNRs (mean: 1.26, range: 1.14–1.34) were not different to male patients(mean=1.24, range=1.11–1.38) (p=0.11). At follow-up HNR was once again significantly bigger (p< 0.01) in females (mean=1.35, range: 1.21–1.49), compare to males (mean=1.27, range:1.11–1.38). HNR alterations with operation (p=0.00) and at follow-up (p< 0.01) were significantly bigger in female patients. Furthermore, there was a significant correlation between high ion levels and HNR change at follow-up for both Co (p=0.02) and Cr (p< 0.01).

Conclusion: This study identified gender-specific changes in HNR that resurfaced hips undergo, not previously documented. Female hips have greater HNR pre-operatively, compared to male hips, and appear to be biomechanically disadvantaged when resurfaced. A decrease in HNR with resurfacing could result in impingement and lead to processes, known to be more prevalent in females, such as neck thinning, increased wear and IP development. In addition, we highlight a correlation between high ion levels and greater neck thinning at follow-up. Increased neck thinning in symptomatic MoMHRA hips could be secondary to increased wear and should be investigated further radiologically for the presence of IP.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 174 - 174
1 May 2011
Grammatopoulos G Kwon Y Langton D Pandit H Gundle R Whitwell D Mclardy-Smith P Murray D Gill H
Full Access

Introduction: Metal-on-metal hip resurfacing arthroplasty (MoMHRA) has gained popularity as an alternative to THR for younger patients with osteoarthritis. A growing concern has been the association of MoMHRA with the development of inflammatory pseudotumours (IP), especially in women. These have been linked to metal-on-metal wear, which can be related to metal ion concentrations. Although cup orientation has been shown to influence wear, the optimum cup position has not been clearly defined. We have identified an optimal cup orientation to minimise IP risk, based on a case controlled study, for inclination/anteversion within ±10° of 40°/20°. Our aim was to see if this optimal position results in lower metal ions, and to identify the boundary of an optimal placement zone for low wear.

Methods: A cohort of 104 patients (60M: 44F) with unilateral MoMHRA was included in this study. Blood tests were obtained at a mean follow up of 3.9 years (range 1.7–7 years) and serum Co and Cr ion levels were measured (ICPMS). High metal ion concentrations were defined as Co> 4.1ppb and Cr> 5.2ppb. Radiographic cup inclination and anteversion were measured using EBRA. The differences in ion levels between different cup orientation zones were investigated. Three orientation zones were defined centered on the target orientation of 40°/20°: Z1 within ±5°, Z2 outside ±5°/within ±10° and Z3: within ±10°.

Results: There was a wide range of cup placements; mean inclination/anteversion were 46.3°(21.5°–64.6°)/15°(2.7°–35.6°). Cr levels, but not Co, were higher in female patients (p=0.002) and those with small femoral components (< 50mm, p =0.03).

For the whole cohort, there was no significant difference in ion levels (Cr: p=0.092. Co=0.075) between cups positioned within Z3 (n=58) versus those outside (n=46 mean). Male patients with cups within Z3 (n=27) had lower ion levels in comparison to those outside Z3, which were significantly lower for Co (p=0.049) but not Cr (p=0.084). Female patients had similar levels within and out of Z3 for both ions (Cr: p=0.83, Co: p=0.84). However, patients with cups within Z1 (n=13) had significantly lower Co (p=0.005) and Cr (p=0.001) than those outside Z1 (n=95). Interestingly, Co levels were significantly lower in Z1 (n=13) in comparison to Z2 (n=33) (p=0.048) but Cr levels were not different (p=0.06).

Discussion: MoMHRA cups placed with ±5° of the ideal position of 40°/20°gave rise to significantly lower metal ions indicating lower wear within this narrow zone, in both sexes. This safe zone, could be extended to ±10° for male patients only. Gender specific factors, such as pelvic anatomy and joint flexibility, could be responsible for the narrower ‘safe’ zone seen in females. The narrower safe zone coupled with smaller components implanted are factors contributing to higher ion levels and hence the increased incidence of IP seen in females.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 54 - 54
1 Jan 2011
Dean B Moore E Matthews J Stubbs D Whitwell D Gibbons C
Full Access

Although originally designed to aid the management of primary malignant bone tumours, the indications for modular endoprosthetic replacement (EPR) have expanded to include complex periprosthetic fractures and failed internal fixation. The incidence of these challenging cases is increasing with an aged population. We reviewed retrospectively our experience with the use of EPR in patients who had undergone limb salvage following complex trauma presentations.

Between 2003 and 2008 twenty one patients underwent EPR following referral to the Oxford Sarcoma Service following lower limb trauma. The average age was 71 years (44–87). The average number of previous surgical procedures was 3 (range 0–11).

The mean Harris Hip Score was 89.5 (range 64–85). The mean American Knee Society Score was 82 (range 62–100) and the mean functional score was 62 (range 30–75). Complications included two cases of deep infection; one resulted in a two stage revision procedure, while the other retained the EPR following a washout. EPR is an effective salvage procedure for failed trauma fixation and periprosthetic fractures. Immediate weight bearing and a good functional outcome can be expected in this difficult group of patients.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 66 - 67
1 Jan 2011
Kwon Y Thomas P Summer B McLardy-Smith P Ostlere S Gundle R Whitwell D Gibbons C Athanasou N Gill H Murray D
Full Access

Introduction: Symptomatic abnormal soft-tissue masses relating to the hip joint, such as those described as pseudotumours, are being increasingly reported following metal-on-metal hip resurfacing arthroplasty (MoMHRA). These were found to be locally destructive, requiring revision surgery in a high proportion (75%) of patients. Lymphocyte infiltrations seen in pseudotumours were similar to aseptic lymphocyte vascular associated lesion (ALVAL), which is thought to represent a T-lymphocyte-mediated delayed type hypersensitivity. Therefore, a delayed hypersensitivity reaction to nickel (Ni), chromium (Cr) or cobalt (Co) has been suggested to play a role in pseudotumour aetiology. In patients with bilateral MoMHRA who presented with symptoms on one side, subsequent scans have demonstrated pseudotumours both on the symptomatic and asymptomatic side. Thus, there are concerns that there may be an appreciable number of asymptomatic pseudotumours that surgeons are unaware of and these may eventually become symptomatic.

Aim: The aims of this study were:

to determine the prevalence of asymptomatic pseudotumours after MoMHRA; and

to measure Co and Cr ion levels as well as lymphocyte proliferation responses to Ni, Co and Cr (the principal elements in the CoCr alloy used in MoMHRA) in MoMHRA patients with and without asymptomatic pseudotumours.

Methods: A total of 201 MoMHRA implanted hips in 158 patients (97 male, 61 female) with a mean age of 56 years (range 33–73 years) were evaluated. The mean follow-up was 61 months (range 13–88 months). Resurfacing devices implanted included 128 Birmingham Hip Resurfacing, 66 Conserve Plus and seven ReCap. The control groups included additional 20 patients, 10 male and 10 female (a mean age 68 years, range 57–80 years) with metal-on-polyethylene total hip arthroplasty and a further 22 age-matched patients (a mean age 55 years) without any metal implants. Ultrasound was used as the initial imaging modality and MRI was used to assess the extent of the identified masses. Patients with a soft-tissue mass had ultrasound-guided aspiration or core biopsy performed. Venous blood samples were collected in all patients for serum cobalt and chromium ion levels analysis using Inductively-Coupled Plasma Mass Spectrometer and lymphocyte transformation tests (LTT). The Oxford Hip Score (OHS) was used to measure the functional outcomes of patients. Acetabular component abduction angle was measured from standardised anteroposterior pelvis radiographs.

Results: Prevalence – Pseudotumours were found in 7 patients (6 female and 1 male). The overall prevalence of asymptomatic pseudotumours was 4%, with a relatively very high (30%) prevalence in females with bilateral implants. Histological examinations showed extensive necrosis of connective tissue, in which there were scattered aggregates of metal particles and a diffuse lymphocyte infiltrate.

Metal Ion Levels – The presence of pseudotumour was associated with significantly higher median serum cobalt levels (9.2mg/L vs. 1.9mg/L, p< 0.001), chromium levels (12.0mg/L vs. 2.1mg/L, p< 0.001), hip aspirate cobalt levels (1182 mg/L vs. 86.2mg/L, p=0.003), and aspirate chromium levels (883mg/L vs. 114.8mg/ L, p=0.006), as well as with inferior functional scores (OHS 41 vs. 47 p< 0.001). There was no significant difference in acetabular cup inclination angle (p=0.51). Lymphocyte Reactivity: A higher incidence and level of enhanced lymphocyte reactivity to Ni (p=0.001), but not to Co or Cr (the principal elements in the CoCr alloy used in metal-on-metal hip resurfacing implants), was found in patients with MoMHRA compared to the patients without MoM implants. However, lymphocyte reactivity to Co, Cr and Ni did not significantly differ in patients with pseudotumours compared to those patients without pseudotumours.

Conclusion: The prevalence of asymptomatic pseudotumours in females was high, especially in females with bilateral MoMHRA implants (30%). The patients with ‘asymptomatic’ pseudotumours were in fact mildly symptomatic. Lymphocyte reactivity to Co, Cr and Ni did not differ in patients with pseudotumour compared to those patients without pseudotumours, suggesting that systemic hypersensitivity type IV reactions, mediated by lymphocyte reactivity to these metals, is not the dominant mechanism in pathogenesis of the soft tissue pseudotumours. Furthermore, pseudotumours were not detected in those patients who had normal levels of cobalt and chromium ions. This suggests that pseudotumours do not occur if MoM articulations are well functioning. Therefore, pseudotumours are likely to be a biological consequence of the large amount of metal debris generated in vivo due to excessive wear.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 79 - 79
1 Jan 2011
White HAB Giele H Critchley P Whitwell D Gibbons CLM
Full Access

Introduction: Acral sarcomas present as small tumours to specialised orthopaedic services. There is a high incidence of inadequate resection compromising clinical and functional outcome.

It is advised that lumps which are greater than 5cm should be referred to a sarcoma centre for management and that small lesions cause less harm with unplanned excision.

Method: Data from the Oxford Registry was collated of all those patients with acral sarcomas who underwent surgery in a period from 1997 – 2008 at The Nuffield Orthopaedic Centre including site, size, histological subtype, of tumours, history of previous surgical excisions, staging, and functional scores.

Results: 27 patients were treated (17 foot and ankle cases, 10 hand tumours). The commonest acral lesions were synovial sarcomas (30%).

Of the hand patients 7 of the 10 patients had wide excision of the lesion with 3 an amputation. 5 of the cases were for inadequate previous excision (50%).

7 of the 17 in the foot and ankle group underwent amputation (41%) the rest wide excision. 29% of cases were for second time surgery due to inadequate previous excision.

Discussion: Our study shows that up to 50% of patients with acral tumours are undergoing further surgery due to previous inadequate excision. The belief that 5cm should be a benchmark for specialist referral should not be applied to such lesions.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 523 - 523
1 Oct 2010
Kwon Y Athanasou N Gill H Gundle R Mclardy-Smith P Murray D Ostlere S Whitwell D
Full Access

Tribological studies of hip arthroplasty suggest that larger diameter metal-on-metal (MOM) articulations would produce less wear than smaller diameter articulations. Other advantages using these large femoral heads implants include better stability with lower dislocation rates and improved range of motion. The aim of the present study was to compare chromium (Cr), cobalt (Co) and titanium (Ti) ion concentrations up to 1-year after implantation of different large diameter MOM total hip arthroplasty (THA).

Methods: Cr, Co and Ti concentrations were measured using a high resolution mass spectrometer (HR-ICP-MS) by an independent laboratory in 110 patients, randomized to receive a large metal-on-metal articulation unce-mented Ti THA from one of the following companies: Zimmer, Smith & Nephew, Biomet or Depuy. Samples of whole blood were collected pre-operatively, and postoperatively at six months and one year.

Summary of Results: At 6 months, whole blood cobalt levels were: (table removed)

Statistical group comparison revealed significant difference for Cr (p=0.006), Co (p=0.047) and Ti (p=< 0.001). With Biomet implants presenting the best results for Cr and Co and Zimmer the highest Ti level.

Discussion: Different implant factors may influence measured metal ion level in whole blood: articular surface wear and implant passive corrosion. Bearing wear may be related to its diameter, quality of the surface finish, component sphericity, radial clearance, manufacturing process (forged vs cast metal) and metal carbon content. Biomet articulation seems to present the best factors selection. Passive corrosion of exposed metallic surfaces is represented by the elevated Ti levels found in all tested systems (Ti was not part of the bearing surfaces). The plasma sprayed acetabular component surface of the Zimmer’s component seems to be responsible for the significant difference in Ti versus the other implants.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 517 - 517
1 Oct 2010
Grammatopoulos G Beard D Gibbons C Gill H Gundle R Mclardy-Smith P Murray D Pandit H Whitwell D
Full Access

Metal on Metal Hip Resurfacing Arthroplasty (MoMHRA) has gained popularity due to its perceived advantages of bone conservation and relative ease of revision to a conventional THR if it fails. Known MoMHRA-associated complications include femoral neck fracture, avascular necrosis/collapse of the femoral head/neck, aseptic loosening and soft tissue responses such as ALVAL and pseudotumours. This study’s aim was to assess the functional outcome of failed MoMHRA revised to THR and compare it with a matched cohort of primary THRs.

Method: We have revised 53 MoMHRA cases to THR; the reasons for revision were femoral neck fracture (Fracture Group, n=21), soft tissue reaction (Pseudotumour Group, n=16) and other causes (Other Group, n=16: loosening, AVN and infection). Average followup was 2.9 years. These MoMHRA revisions were compared with 103 matched controls from a primary THR cohort; matched for age, gender and length of followup. We compared, using the MannWhitney U test, operative time (OT, measured in minutes), and Oxford Hip Score (OHS) between the revised MoMHRA groups and their individual controls. We also compared, using the Kruskal Wallis test, UCLA Activity Score in the revised MoMHRA groups.

Results: There were no differences between the Fracture Group (mean OT 99.6, SD: 30.4; mean OHS 19.8, SD:9.2) and its controls (mean OT 95.9, SD: 31.8; mean OHS 17.3, SD: 7.5) nor between the Other Group (mean OT 129.4, SD: 36.7; mean OHS 22.2, SD: 9.4) and its controls (mean OT 104.4, SD: 39.2; mean OHS 20.3, SD: 10.1) in terms of OT and OHS. The Pseudotumour Group had significantly longer OT (mean 161.6, SD: 24.5, p< 0.001) and worse outcome (mean OHS 39.1, SD: 9.3, p< 0.001) than its controls (mean OT 113.1, SD: 51.7; mean OHS 20.0, SD: 9.2). In the Fracture Group, there were 3 infections requiring revisions. For the Pseudotumour Group, there were 3 recurrent dislocations, 1 femoral artery stenosis and 3 femoral nerve palsies. In the Other Group, there were 2 periprosthetic fractures. There was significant difference (p< 0.001) in UCLA scores between the MoMHRA groups. The Pseudotumour Group had the lowest mean UCLA score of 3.8 (SD: 1.89). The Fracture Group (mean: 7.0, S.D. 2.0) and the Other Group (mean: 6.7, S.D. 2.1) had similar UCLA scores.

Discussion: The results demonstrate that outcome after revision of MoMHRA is dependent upon the indication for revision. Patients revised for soft tissue reactions had significantly worse outcome. Patients with soft tissue reactions are more likely to experience complications and require further surgical intervention. The pseudotumour associated revisions were associated with a significantly prolonged OT. The overall complication rate for the study groups was quite high, with 11 (21%) revised MoMHRA cases experiencing a complication. The Pseudotumour Group had a higher complication rate (37%).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1072 - 1078
1 Aug 2010
Grammatopoulos G Pandit H Glyn-Jones S McLardy-Smith P Gundle R Whitwell D Gill HS Murray DW

Pseudotumours are a rare complication of hip resurfacing. They are thought to be a response to metal debris which may be caused by edge loading due to poor orientation of the acetabular component. Our aim was to determine the optimal acetabular orientation to minimise the risk of pseudotumour formation.

We matched 31 hip resurfacings revised for pseudotumour formation with 58 controls who had a satisfactory outcome from this procedure. The radiographic inclination and anteversion angles of the acetabular component were measured on anteroposterior radiographs of the pelvis using Einzel-Bild-Roentgen-Analyse software. The mean inclination angle (47°, 10° to 81°) and anteversion angle (14°, 4° to 34°) of the pseudotumour cases were the same (p = 0.8, p = 0.2) as the controls, 46° (29° to 60°) and 16° (4° to 30°) respectively, but the variation was greater. Assuming an accuracy of implantation of ± 10° about a target position, the optimal radiographic position was found to be approximately 45° of inclination and 20° of anteversion. The incidence of pseudotumours inside the zone was four times lower (p = 0.007) than outside the zone.

In order to minimise the risk of pseudotumour formation we recommend that surgeons implant the acetabular component at an inclination of 45° (± 10) and anteversion of 20° (± 10) on post-operative radiographs. Because of differences between the radiographic and the operative angles, this may be best achieved by aiming for an inclination of 40° and an anteversion of 25°.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 390 - 390
1 Jul 2010
Kwon Y Ostlere S Mclardy-Smith P Gundle R Whitwell D Gibbons C Taylor A Pandit H Glyn-Jones S Athanasou N Beard D Gill H Murray D
Full Access

Introduction: Despite the satisfactory short-term implant survivorship of MoM hip resurfacing arthroplasty, symptomatic abnormal periprosthetic soft-tissue masses relating to the hip joint, ‘pseudotumours’, are being increasingly reported. These were found be locally destructive, requiring revision surgery in 75% of patients. Asymptomatic pseudotumours have not been previously investigated.

Methods: The aims were: (1) to investigate the prevalence of asymptomatic pseudotumours; and (2) to investigate their potential association with the level of metal ions. A total of 160 hips in 123 patients with a mean age 56 years (range 33–73) were evaluated at a mean follow-up of 61 months (range 13–88). Radiographs and OHS were assessed. Patients with a cystic or solid mass detected on the ultrasound/MRI had an aspiration or biopsy performed. Cobalt and chromium levels were analysed using Inductively-Coupled Plasma Spectrometer.

Results: Pseudotumours were found in 6 patients (5F: 1M). In 80% of bilateral cases, it was found in both sides. Histological examination showed extensive necrosis and diffuse lymphocyte infiltration. The presence of pseudotumour was associated with higher serum cobalt (9.2 μg/L vs. 1.9μg/L, p< 0.001) and chromium levels (12.0μg/L vs. 2.1μg/L, p< 0.001); higher hip aspirate cobalt (1182 μg/L vs. 86.2μg/L, p=0.003) and chromium levels (883μg/L vs. 114.8μg/L, p=0.006); and with inferior OHS (23 vs. 14 p=0.08).

Discussion: The prevalence of asymptomatic pseudotumour (5%) was higher than previously reported for the symptomatic pseudotumours (1%). There was a sixfold elevation of serum and a twelve-fold elevation of hip aspirate levels of cobalt and chromium in patients with pseudotumours. This suggests that pseudotumours may be a biological consequence of the large amount of metal debris generated in vivo. The association between pseudotumour and elevated metal ion levels might theoretically be explained by either systemic hypersensitivity responses to metal ions or local cytotoxic effects due to a high level of metal ions.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 307 - 307
1 May 2010
Pandit H Glynjones S Gundle R Gibbons C Mclardy-Smith P Whitwell D Athanasou N Gill H Murray D
Full Access

Introduction: We report on a group of 20 metal-onmetal resurfaced hips (17 patients) presenting with a soft tissue mass associated with various symptoms; these masses we termed pseudotumours.

Methods: All patients underwent plane radiography; CT, MRI and ultrasound investigations were also performed for some patients. Where samples were available histology was performed. Metal ion levels were measured in six patients and one patient had the metal ion levels in the joint fluid measured.

Results: All patients in this series were female. Presentation was variable; the most common symptom was pain or discomfort in the hip region. Other symptoms included spontaneous dislocation, nerve palsy, a noticeable mass or a rash. In all cases a soft tissue mass was present in the region of the hip, this was either solid or cystic. The common histological features were extensive necrosis and lymphocytic infiltration. The blood cobalt and chromium levels varied considerably between the six patients that had these measurements. The median blood chromium level was 3.8 μg/L (range 0.8 to 23 μg/L) and that for cobalt was 11.5 μg/L (range 2.1 to 15 μg/L). The synovial fluid sample taken from a single joint contained much higher metal levels, 701 μg/L for chromium and 329 μg/L for cobalt. Twelve of the 20 cases have so far required revision to a conventional hip replacement.

Discussion: This complication is best imaged with ultrasound, and is not detected by normal xray. We estimate that about 1% of patients develop a pseudotumour in the first five postoperative years. The cause of these pseudotumours is unknown and is probably multifactorial, further work is required to define this; they may be manifestations of a metal sensitivity response. We are concerned that with time the incidence of these pseudo-tumours will increase.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 307 - 307
1 May 2010
Padnis A Whitwell D Delport H Singhal K
Full Access

Aim: The purpose of the study was to compare the position of the femoral guide wire for during hip resurfacing, computer navigation and an alignment device.

Materials and Methods: 26 cadaver specimens divided in 3 randomly selected groups and 25 patients were used to evaluate the position of the femoral guide wire in resurfacing hip arthroplasty. In two groups of cadavers the Computer Navigation was used to register and template the position of the implant. The position of the guide wire was compared to the one achieved using the alignment device. In the third group of cadaver specimens only the alignment device was used to implant the guide wire. Version was determined from the transversely cut sections of the cadaver specimens. Pre operative and post operative radiographs were used for analysis. In the patient group after registration and templating the guide wire was passed using the alignment device.

Results: There was no notching of the superior femoral neck in either of the groups. The mean and standard deviation of the anatomic neck-shaft angles was 124.91? ? 14.25?. The wire-shaft angle in the Navigation group was 131.46? ? 5.27? and in the alignment device group 134.08? ? 3.80?. In the navigation group the wire was in 0.85? ? 2.15? of retroversion as compared to 1.38? ? 4.19? of anteversion in Jig group. The position of the wires at the narrowest cross section of the femoral neck is shown in figure. The wire shaft angle as per navigation was 134.44(±5.55) as compared to 134.74 (±5.11).

Conclusion: The alignment device consistently positioned the wire more valgus and anteverted than Computer aided navigation. In all cases, the wire position was well within acceptable limits. Computer aided navigation does not seem to offer distinct advantages in resurfacing hip replacements.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 66 - 67
1 Mar 2010
Smith G Machado B Whitwell D
Full Access

The treatment of acetabular metastases with total hip arthroplasty is technically challenging often with significant loss of structural continuity in the medial wall and roof of the acetabulum, as described by Harrington in 1981 as class III defects. Traditionally the acetabular component is stabilised with Harrington rods but the risk of post-operative complications, especially bleeding is significant.

We performed 10 consecutive total hip arthroplasties in patients with metastases involving the acetabulum with Harrington class III defects. The first three patients had acetabular reconstruction with a Kerboull cage, (Stryker Howmedica.) The cage was secured using a combination of screw fixation to the ileum and PMMA cement filling voids behind the cage. A polyethylene acetabular cup is then cemented into the cage. There was concern about the superior fixation using this implant and so the remaining 7 patients were treated using the Graft Augmentation Prosthesis (GAP II), (Stryker How-medica.) This is a titanium reconstruction cage with two superior flanges allowing extensive screw fixation onto the ileum. Two patients had very large defects where there was not sufficient support to use this cage alone, so the technique was augmented with Harrington rods.

No implants have failed to date. One patient, an 83 year old female, died 23 days post-operatively after suffering a stroke. Two patients died of their disease 95 and 115 days after surgery. The remaining patients continue to have good pain and mobility following surgery as demonstrated by the Oxford hip score.

We conclude that in suitable patients with extensive metastatic involvement of the acetabulum, a flanged acetabular reconstruction cage prosthesis is much improved way of providing support for a total hip replacement. This procedure can greatly improve quality of life, and to date we have had no mechanical failures of fixation using this technique.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 500 - 500
1 Sep 2009
Monk P Pandit H Gundle R Whitwell D Ostlere S Athanasou N Gill H McLardy-Smith P Murray D Gibbons C
Full Access

We report on a group of 20 metal-on-metal resurfaced hips (17 patients) presenting with a soft tissue mass associated with various symptoms. We describe these masses as pseudotumours.

All patients underwent plain radiography and fuller investigation with CT, MRI and ultrasound. Where samples were available, histology was performed. All patients in this series were female. Presentation was variable; the most common symptom was pain or discomfort in the hip region. Other symptoms included spontaneous dislocation, nerve palsy, an enlarging mass or a rash. The common histological features were extensive necrosis and lymphocytic infiltration. Fourteen of the 20 cases (70%) have so far required revision to a conventional hip replacement and their symptoms have either settled completely or improved substantially since the revision surgery. Two of the three bilateral cases have asymptomatic pseudotumours on the opposite side.

We estimate that about 1% of patients develop a pseudotumour in the first five postoperative years after a hip resurfacing. The cause of these pseudotumours is unknown and is probably multi-factorial, further work is required to define this; they may be manifestations of a metal sensitivity response. We are concerned that with time the incidence of these pseudotumours will increase.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 406 - 406
1 Sep 2009
Pandit H Glyn-Jones S Gundle R Whitwell D Gibbons C Ostlere S Athanasou N Gill H McLardy-Smith P Murray D
Full Access

Introduction: We report on a group of 20 metal-on-metal resurfaced hips (17 patients) presenting with a soft tissue mass associated with various symptoms; these masses we termed pseudotumours. All patients underwent plane radiography; CT, MRI and ultrasound investigations were also performed for some patients. Where samples were available histology was performed.

Methods: All patients in this series were female. Presentation was variable; the most common symptom was pain or discomfort in the hip region. Other symptoms included spontaneous dislocation, nerve palsy, a noticeable mass or a rash. The common histological features were extensive necrosis and lymphocytic infiltration. Fourteen of the 20 cases (70%) have so far required revision to a conventional hip replacement and their symptoms have either settled completely or improved substantially since the revision surgery. Two of the three bilateral cases have asymptomatic pseudotumours on the opposite side.

Conclusions: We estimate that about 1% of patients develop a pseudotumour in the first five postoperative years after a hip resurfacing. The cause of these pseudotumours is unknown and is probably multi-factorial, further work is required to define this; they may be manifestations of a metal sensitivity response. We are concerned that with time the incidence of these pseudotumours will increase.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 567 - 567
1 Aug 2008
Harvie P McLardy-Smith P Whitwell D
Full Access

Introduction: Optimal positioning of the femoral component in hip resurfacing is determined by accurate guidwire placement in the centre of the femoral neck. This can be a challenging procedure. The more extensile approach needed, patient size, the shape of the femoral head and the presences of osteophytes can all result in sub-optimal guidewire positioning and ultimately in varus insertion or femoral notching both of which have been shown to increase the risk of post-operative fracture, the commonest cause of implant failure. Various alignment guides are available but these are cumbersome and time consuming and their accuracy is highly operator dependent. Anecdotally, accuate guidewire insertion is regarded as the most challenging part of this procedure with heightened anxiety levels particularly when low down on the‘learning curve’.

Methods: We describe the technique, difficulties and learning curve experienced with the first ten navigated hip resurfacing procedures at our institution. Post-operative radiographs were obtained and randomly incorporated into a series of 40 post-operative resurfacing radiographs. Radiographic assessment was undertaken by a senior colleague with experience of over 600 resurfacing procedures (blinded to which cases utilised navigation) and classified as poor, satisfactory or good.

Results: The use of navigation in femoral resurfacing has a definite but short learning curve. It provides a means of achieving excellent alignment of the femoral component without any subjective increase in operation time. Anxiety levels associated with accurate guidewire positioning are greatly reduced. Navigation should offer benefits to all surgeons particularly those low down on the ‘learning curve’ for this procedure reducing the risk of femoral component malpositioning and early failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 847 - 851
1 Jul 2008
Pandit H Glyn-Jones S McLardy-Smith P Gundle R Whitwell D Gibbons CLM Ostlere S Athanasou N Gill HS Murray DW

We report 17 patients (20 hips) in whom metal-on-metal resurfacing had been performed and who presented with various symptoms and a soft-tissue mass which we termed a pseudotumour. Each patient underwent plain radiography and in some, CT, MRI and ultrasonography were also performed. In addition, histological examination of available samples was undertaken.

All the patients were women and their presentation was variable. The most common symptom was discomfort in the region of the hip. Other symptoms included spontaneous dislocation, nerve palsy, a noticeable mass or a rash. The common histological features were extensive necrosis and lymphocytic infiltration. To date, 13 of the 20 hips have required revision to a conventional hip replacement. Two are awaiting revision.

We estimate that approximately 1% of patients who have a metal-on-metal resurfacing develop a pseudotumour within five years. The cause is unknown and is probably multifactorial. There may be a toxic reaction to an excess of particulate metal wear debris or a hypersensitivity reaction to a normal amount of metal debris. We are concerned that with time the incidence of these pseudotumours may increase. Further investigation is required to define their cause.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 398 - 398
1 Jul 2008
Glyn-Jones S Pandit H Whitwell D Athanasou N Gibbons M
Full Access

Purpose of study: We report the results of a prospective case series of 10 patients who developed tumour-like masses following resurfacing arthroplasty

Method: Ten subjects were referred to the tumour service at the Nuffield Orthopaedic Centre with symptomatic masses around the hip, all had previously received a resurfacing arthroplasty.

We report the clinical, radiographic and histologic features of these cases.

Results: MRI and ultrasound scanning was preformed, which demonstrated masses with solid and cystic components.

Biopsy was performed and subsequent histological examination revealed a profound plasma-cell lymphocytic response associated with metal wear debris.

There were no infections in this series.

Three subjects required revision surgery.

Conclusion: Over 50,000 resurfacing arthroplasties have been implanted worldwide over the past ten years. Although the early clinical results are encouraging little is known about the long term consequences of large head metal on metal bearing surfaces. Despite this, these devices are being widely marketed and are often implanted in younger patients. Resurfacing arthroplasties are associated with high serum and urine metal ion concentrations, metal particles have also been shown to migrate along the lymphatic system. In addition, there is now evidence that high local metal ion concentrations can induce haempoietic cancers.

This study suggests that resurfacing arthoplasty can also induce a local hypersensitivity reaction in response to metal wear debris. It therefore raises new concerns regarding the long-term safety of this procedure.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 298 - 298
1 May 2006
Gwilym S Whitwell D Giele H Gibbons C
Full Access

Purpose: To assess the functional outcome of patients who pre-operatively, were known to have sciatic nerve tumour involvement and proceeded to have nerve-preserving planned marginal excision with epineurectomy.

Methods: We identified patients who had surgery between 1997 and 2004, for soft tissue sarcomas in the posterior thigh with known sciatic nerve involvement. During this period it was the practice of the senior authors (MG & HG) to apply a nerve-preserving epineurectomy approach as part of their planned marginal excision of these tumours.

The identified patients had their notes reviewed, and were contacted by post to complete a Toronto Extremity Severity Score (TESS) questionnaire to assess lower limb function in day-to-day life. Details of their presenting features, oncological work-up, surgical intervention and adjuvant therapy was established and correlated to the TESS score.

Conclusion: This study demonstrates that a careful epineurectomy can preserve sciatic nerve function and allow tumour excision with no increase in local recurrence rate. With good soft tissue cover it appears nerve function can be maintained, even in cases where adjuvant radiotherapy is indicated.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1035 - 1040
1 Nov 1999
Atkins RM Madhavan P Sudhakar J Whitwell D

The ipsilateral and contralateral fibulae have been used as a vascularised bone graft for loss of tibial bone usually by methods which have involved specialised microvascular techniques to preserve or re-establish the blood supply.

We have developed a method of tibialisation of the fibula using the Ilizarov fixator system, ipsilateral vascularised fibular transport (IVFT), and have used it in five patients with massive loss of tibial bone after treatment of an open fracture, infected nonunion or chronic osteomyelitis. All had successful transport, proximal and distal union, and hypertrophy of the graft without fracture. One developed a squamous-cell carcinoma which ultimately required amputation of the limb.

The advantage of IVFT is that the fibular segment retains its vascularity without the need for microvascular dissection or anastomoses. Superiosteal formation of new bone occurs if the tibial periosteal bed is retained. Other procedures such as corticotomy and lengthening can be carried out concurrently.