PSEUDOTUMOURS ASSOCIATED WITH METAL-ON-METAL HIP RESURFACINGS



Abstract

Introduction: We report on a group of 20 metal-onmetal resurfaced hips (17 patients) presenting with a soft tissue mass associated with various symptoms; these masses we termed pseudotumours.

Methods: All patients underwent plane radiography; CT, MRI and ultrasound investigations were also performed for some patients. Where samples were available histology was performed. Metal ion levels were measured in six patients and one patient had the metal ion levels in the joint fluid measured.

Results: All patients in this series were female. Presentation was variable; the most common symptom was pain or discomfort in the hip region. Other symptoms included spontaneous dislocation, nerve palsy, a noticeable mass or a rash. In all cases a soft tissue mass was present in the region of the hip, this was either solid or cystic. The common histological features were extensive necrosis and lymphocytic infiltration. The blood cobalt and chromium levels varied considerably between the six patients that had these measurements. The median blood chromium level was 3.8 μg/L (range 0.8 to 23 μg/L) and that for cobalt was 11.5 μg/L (range 2.1 to 15 μg/L). The synovial fluid sample taken from a single joint contained much higher metal levels, 701 μg/L for chromium and 329 μg/L for cobalt. Twelve of the 20 cases have so far required revision to a conventional hip replacement.

Discussion: This complication is best imaged with ultrasound, and is not detected by normal xray. We estimate that about 1% of patients develop a pseudotumour in the first five postoperative years. The cause of these pseudotumours is unknown and is probably multifactorial, further work is required to define this; they may be manifestations of a metal sensitivity response. We are concerned that with time the incidence of these pseudo-tumours will increase.

Correspondence should be addressed to: EFORT Central Office, Technoparkstrasse 1, CH – 8005 Zürich, Switzerland. Email: office@efort.org