header advert
Results 1 - 14 of 14
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 11 - 11
1 Apr 2019
Wong M Desai B Bautista M Kwon O Chimento G
Full Access

PURPOSE

YouTube is a video sharing platform that is a common resource for patients seeking medical information. The objective of this study is to assess the educational quality of YouTube videos pertaining to total knee arthroplasty and knee arthritis.

METHODS

A systematic search for the terms “knee replacement” and “knee arthritis” was performed using Youtube's search function. Data from the 60 most relevant videos were collected for each search term. Videos not in English or those without audio or captions were excluded. Quality assessment checklists with a scale of 0 to 10 points were developed to evaluate the video content. Videos were grouped into poor quality (grade 0–3), acceptable quality (grade 4–7) and excellent quality (grade 8– 10), respectively. Four independent reviewers assessed the videos using the same grading system and independently scored all videos. Discrepancies regarding the scoring were clarified by consensus discussion.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 20 - 27
1 Jan 2018
Kang K Son J Suh D Kwon SK Kwon O Koh Y

Objectives

Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient’s own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA.

Methods

The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs.


Objectives

Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA.

Methods

We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior direction, and -3°, 0°, 3° and 6° PTS models with each of the PCO models. Using a validated finite element (FE) model, we investigated the influence of the changes in PCO and PTS on the contact stress in the patellar button and the forces on the posterior cruciate ligament (PCL), patellar tendon and quadriceps muscles under the deep knee-bend loading conditions.


Bone & Joint Research
Vol. 6, Issue 11 | Pages 623 - 630
1 Nov 2017
Suh D Kang K Son J Kwon O Baek C Koh Y

Objectives

Malalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions.

Methods

Validated finite element models for varus and valgus malalignment by 3° and 5° were developed to evaluate the effect of malalignment on the tibial component in TKA. Maximum contact stress and contact area on a polyethylene insert, maximum contact stress on patellar button and the collateral ligament force were investigated.


Objectives

Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA.

Methods

We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.


Bone & Joint Research
Vol. 5, Issue 11 | Pages 552 - 559
1 Nov 2016
Kang K Koh Y Son J Kwon O Baek C Jung SH Park KK

Objectives

Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments.

Materials and Methods

Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 27 - 27
1 May 2016
Kwon O Baek C Kang K Son J Koh Y
Full Access

Unicompartmental knee arthroplasty (UKA) is often considered to be attractive alternate surgical technique to total knee arthroplasty (TKA) and high tibial osteotomy (HTO), in particular young patients. In addition, it is recently reported that preservation of joint line in UKA is crucial factor for positive long-term outcome, especially in revision case for UKA. However, the role of this joint line has neither been invested nor is it consciously bothered during surgical implantation.

Validated finite element (FE) analysis was introduced in this study to investigate the effects of maximum contact stress on polyethylene (PE) insert and maximum compressive stress in opposite compartments for joint line in fixed-type UKA. As suggested by Weber et al., FE model for joint line was developed by means of determination of the angle between the pre-operative joint line and the reference line from lateral cortical is of the femur. Based on the method above, joint lines were modeled in −3, −2, −1, 0, +1, +2, and +3 mm cases and these seven FE models were compared and analyzed (Fig. 1). All implant components were modeled as linear elastic isotropic materials. However, the model was considered to have plastic characteristics of PE insert. FE analysis was performed using high kinematics displacement and rotation inputs, which were based on the kinematics of the natural knee. ISO standards were used for axial load and flexion (Fig. 2).

The FE model was subjected to validation based on cadaveric experimental data available in the literature by Sohn et al. and from previous cadaveric tests conducted by current investigators. The maximum contact stress was found at around 43 % of the gait cycle in 0 mm case. There were no difference between ± 1 and 0 mm cases, but maximum contact stress on PE insert becomes greater in ± 3 mm cases. The maximum compressive stress of the lateral meniscus in 0 mm case occurred at 62 % of the gait cycle. There were no difference in positive joint line cases in maximum compressive stress, however maximum compressive stress of the lateral meniscus becomes greater in - 3 mm cases.

This study emphasized the importance of joint line preservation after implantation of UKA. It would be critical to determine the joint line in UKA surgery in future based on the result showing that there has been no remarkable difference in stress but changed rapidly from the position beyond the joint line. In future study, it would be valuable study to compare between joint lines of fixed- and mobile-type UKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 143 - 143
1 May 2016
Yoon S Lee C Hur J Kwon O Lee H
Full Access

Introduction

Mechanically aligned total knee arthroplasty(TKA) relies on restoring the hip-knee-ankle angle of the limb to neutral or as close to a straight line as possible. This principle is based on studies that suggest limb and knee alignment is related long term survival and wear. For that cause, there has been recent attention concerning computer-assisted TKA and robot is also one of the most helpful instruments for restoring neutral alignment as known. But many reported data have shown that 20% to 25% of patients with mechanically aligned TKA are dissatisfied. Accordingly, kinematically aligned TKA was implemented as an alternative alignment strategy with the goal of reducing prevalence of unexplained pain, stiffness, and instability and improving the rate of recovery, kinematics, and contact forces. So, we want to report our extremely early experience of robot-assisted TKA planned by kinematic method.

Materials and Methods

This study evaluated the very short term results (6 weeks follow up) after robot-assisted TKA aligned kinematically. 50 knees in 36 patients, who could be followed up more than 6 weeks after surgery from December 2014 to January 2015, were evaluated prospectively. The diagnosis was primary osteoarthritis in all cases. The operation was performed with ROBODOC (ISS Inc., CA, USA) along with the ORTHODOC (ISS Inc., CA, USA) planning computer. The cutting plan was made by single radius femoral component concept, each femoral condyles shape-matched method along the transverse axis using multi-channel CT and MRI to place the implant along the patient's premorbid joint line. Radiographic measurements were made from long bone scanograms. Clinical outcomes and motion were measured preoperatively and 6 weeks postoperatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 367 - 367
1 Mar 2013
Yoon S Lee C Hur J Kwon O Trabish M Lee H Park J
Full Access

Introduction

The success of total knee arthroplasty depends on many factors, including the preoperative condition of the patient, the design and materials of the components and surgical techniques. It is important to position the femoral and tibial components accurately and to balance the soft tissues. Malpositioning of the component can lead to failures due to aseptic loosening, instability, polyethylene wear and dislocation of the patella. In order to improve post-operative alignment, computer-aid systems have been developed for total knee arthroplasty. Many clinical and experimental studies of these systems have shown that the accuracy of implanted components can be improved in spite of the increase in costs and operating time. This may not, however, improve the outcome in the short-term. Restoration of the normal mechanical axis of the knee and balancing of the surrounding soft tissues have been shown to have an important bearing on the final outcome of knee replacement operations. In severely deformed knees, whether varus or valgus, these goals may be difficult to achieve. We compared the radiologic results of the mechanical axis and implant position of Total Knee Arthroplasty using a robot-assisted method with conventional manually implanted method in severe varus deformed knee.

Materials and Methods

A data set of 50 consecutive cases that were performed from April 2007 to December 2010 using the robot assisted TKA(Group A) were compared with a data set of 50 consecutive cases from the same period that were done using conventional manual TKA(Group B). All cases had a preoperative mechanical varus deformity >15° and one brand of implant was used on all cases. The diagnosis was primary osteoarthritis in all knees. The operations were performed by one-senior author with the same robot system, ROBODOC (ISS Inc., CA, USA) along with the ORTHODOC (ISS Inc., CA, USA) planning computer. (See Figure 1.) The radiological evaluations included mechanical axis, implant position (α,β,γ,δ angle) according to the system of American Knee Society.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 366 - 366
1 Mar 2013
Yoon S Lee C Hur J Kwon O Trabish M Lee H Park J
Full Access

Introduction

Since Smith-Peterson's glass mold arthroplasty in 1939, hip resurfacing arthroplasty was developed and introduced to orthopaedic surgery field but it had many problem like early loosening. Recently it is being popular for some indication as development of new implant design and manufacturing. There are still many suggested advantages of hip resurfacing arthroplasty. These include bone conservation, improved function as a consequence of retention of the femoral head and neck and more precise biomechanical restoration, decreased morbidity at the time of revision arthroplasty, reduced dislocation rates, normal femoral loading and reduced stress-shielding, simpler management of a degenerated hip with a deformity in the proximal femoral metaphysic, an improved outcome in the event of infection, and a reduced prevalence of thromboembolic phenomena as a consequence of not using instruments in the femur. But, there are limited or inconsistent data to support some of these claims regarding the benefits of hip resurfacing including the potential for a more natural feel because of the minimal disturbance of the proximal part of the femur resulting in a better and faster functional outcome. We evaluate the short term results of hip resurfacing arthroplasty using custom patient-specific tooling for prosthesis placement for better standardization.

Materials and Methods

40 cases, 36 patients(male:20, female:16) those of who were candidates of a Hip Resurfacing procedure, participated in the study. Mean follow up period was 2.5 years (8 months ∼3 years). A CT scan was performed on each patient and a 3D model was generated using the computer tomography dataset. From this model a bone-surface skin was extracted and this data set was used to create a personalized jig. Detailed analysis of the native bone structure was then used to preoperatively plan the appropriate size and position of the implant. A mean 7 degree corrective valgus angle was prescribed on all cases. Postoperative radiological datasets were superimposed onto preoperative plan position and offsets were measured. Operative times were recorded per step during the procedure. Surgeon comfort and ease of use was also noted.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 124 - 124
1 Jun 2012
Kwon O Kamath A Voleti P Garino J
Full Access

Introduction

While the use of stemmed implants is accepted for patients with medial ligament laxity in primary total knee arthroplasty (TKA), the role of stemmed implants in the setting of isolated lateral laxity is unclear. We present a cohort study to assess the effect of unstemmed, constrained TKA for isolated lateral laxity.

Methods

1745 primary TKA performed by the senior surgeon were reviewed. 39 knees in 33 patients with isolated lateral laxity managed with unstemmed components were compared to matched stemmed controls (37 knees in 28 patients). Lateral instability was defined intra-operatively based on >7mm gap in mid-flexion/full extension/figure-of-four with well-positioned components. Primary outcome measures were clinical failure for aseptic loosening (with need for revision as the endpoint) and any radiographic signs of loosening.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 539 - 539
1 Oct 2010
Kim Y Choi Y Kim J Kwon O
Full Access

Background: Whether total knee arthroplasty using computer-assisted surgical navigation can improve the limb and component alignment is a matter of debate. We hypothesized that total knee arthroplasty using computer-assisted surgical navigation is superior to the conventional total knee arthroplasty with regard to the precision of implant positioning.

Methods: Sequential simultaneous bilateral total knee arthroplasties were carried out in 160 patients (320 knees). One knee was replaced using a computer-assisted surgical navigation system and the other conventionally without using computer-assisted surgical navigation. The two methods were compared for accuracy of orientation and alignment of the components determined by radiographs and computed tomographs. The mean follow-up was 3.4 years.

Results: The mean preoperative Knee Society score was 26 points in the computer-assisted total knee arthroplasty group, which was improved to 92 points postoperatively and it was 25 points, which improved to 93 points post-opertively in the conventional total knee arthroplasty group. Ranges of motion of the knees were similar in both groups. The operating and tourniquet times were significantly longer in the computer-assisted total knee arthroplasty group than in the conventional total knee arthroplasty group (P< 0.001). Accuracy and the number of outliers of component position between the two groups were not significantly different (P> 0.05).

Conclusions: Our data demonstrated that total knee arthroplasty using computer-assisted surgical navigation did not result in more accurate implant positioning than that achieved in conventional total knee arthroplasty, determined by both radiographs and computed tomographs.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 136 - 136
1 Mar 2010
Kwon O Kim Y Bae D
Full Access

The use of stem provides consistent component alignment with immediate stable fixation and protects grafted bone by reducing stress on metaphyseal area in revision total knee arthroplasty. One of major concern with use of stems involves stem tip pain in cementless diaphyseal engaging stem. The purpose of this study is to evaluate the effect of stem design and method of fixation on stem tip pain in revision total knee arthroplasty by finite element analysis.

3D finite element model of normal tibia was reconstructed from CT scan images of 26 year old male and the CAD model of revision total knee arthroplasty was developed using commercial software(CATIA®, Dassault system, USA, version 8.20). The tibia component models were assembled based on conventional surgical procedure. The design changes of stem such as the length, diameter and slot were performed and methods of fixation including press fit and coefficient of friction was considered. The contact pressure and von-Mises stress around the stem and the micromotion at the interface were evaluated for a 2000 N of external load by finite element analysis to investigate the effect of stem design and methods of fixation on stem tip pain. The longer length and larger diameter press fit stem significantly increase the contact pressure & stress at the end of stem. The distal slot reduces the contact pressure & stress at the end of stem. Less displacement between tibial component and bone was noted in the increased coefficient of friction.

It would be better to avoid using press fit stem with extended length and larger diameter in revision total knee arthroplasty. More flexibility of stem tip would be favorable because of less concentration of stress. Stem fixation with higher coefficient of friction would be recommended for less displacement of tibial component. Stem with shorter length enough to engage proximal diaphysis, closer diameter of proximal canal and minimal press fit could be accepted to reduce stem tip pain if patient’s surgical anatomy such as bone loss and quality is tolerable in revision total knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 316 - 320
1 Mar 2009
Kim Y Kwon O Kim J

We investigated whether simultaneous bilateral sequential total hip replacement (THR) would increase the rate of mortality and complications compared with unilateral THR in both low- and high-risk groups of patients.

We enrolled 978 patients with bilateral and 1666 with unilateral THR in the study. There were no significant pre-operative differences between the groups in regard to age, gender, body mass index, diagnosis, comorbidity as assessed by the grading of the American Society of Anesthesiologists (ASA), the type of prosthesis and the duration of follow-up. The mean follow-up was for 10.5 years (5 to 13) in the bilateral THR group and 9.8 years (5 to 14) in the unilateral group.

The peri-operative mortality rate of patients who had simultaneous bilateral THR (0.31%, three of 978 patients) was similar to that of patients with unilateral THR (0.18%, three of 1666 patients). The peri-operative mortality rate of patients in the bilateral group was similar in high risk and low risk patients (0.70%, two of 285 patients vs 0.14%, one of 693 patients) and this was also true in the unilateral THR group (0.40%, two of 500 patients vs 0.09%, one of 1166 patients). Patients with bilateral THR required more blood transfusions and a longer hospital stay than those in the unilateral THR group. There was no significant difference (p = 0.32) in the overall number of complications between the groups. This was also true for the low-risk (p = 0.81) vs high-risk (p = 0.631) patients.

Our findings confirm that simultaneous sequential bilateral THR is a safe option for patients who are considered to be either high or low risk according to the ASA classification.