header advert
Results 1 - 80 of 80
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 380 - 386
1 Apr 2024
Cho J Lee S Kim D Oh W Koh I Chun Y Choi Y

Aims

The study aimed to assess the clinical outcomes of arthroscopic debridement and partial excision in patients with traumatic central tears of the triangular fibrocartilage complex (TFCC), and to identify prognostic factors associated with unfavourable clinical outcomes.

Methods

A retrospective analysis was conducted on patients arthroscopically diagnosed with Palmer 1 A lesions who underwent arthroscopic debridement and partial excision from March 2009 to February 2021, with a minimum follow-up of 24 months. Patients were assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, Mayo Wrist Score (MWS), and visual analogue scale (VAS) for pain. The poor outcome group was defined as patients whose preoperative and last follow-up clinical score difference was less than the minimal clinically important difference of the DASH score (10.83). Baseline characteristics, arthroscopic findings, and radiological factors (ulnar variance, MRI, or arthrography) were evaluated to predict poor clinical outcomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 147 - 147
11 Apr 2023
Baker M Clinton M Lee S Castanheira C Peffers M Taylor S
Full Access

Osteoarthritis (OA) of the equine distal interphalangeal joint (DIPJ) is a common cause of lameness. MicroRNAs (miRNAs) from biofluids such as plasma and synovial fluid make promising biomarker and therapeutic candidates.

The objectives of this study are (1) Identify differentially expressed (DE) miRNAs in mild and severe equine DIPJ OA synovial fluid samples and (2) Determine the effects of DE miRNAs on equine chondrocytes in monolayer culture.

Synovial fluid samples from five horses with mild and twelve horses with severe DIPJ OA were submitted for RNA-sequencing; OA diagnosis was made from MRI T2 mapping, macroscopic and histological evaluation. Transfection of equine chondrocytes (n=3) was performed using the Lipofectamine® RNAiMAX system with a negative control and a miR-92a mimic and inhibitor. qPCR was used to quantify target mRNA genes.

RNA-seq showed two miRNAs (miR-16 and miR-92a) were significantly DE (p<0.05). Ingenuity Pathway Analysis (IPA) identified important downstream targets of miR-92a involved in the pathogenesis of osteoarthritis and so this miRNA was used to transfect equine chondrocytes from three donor horses diagnosed with OA. Transfection was successfully demonstrated by a 1000-20000 fold increase in miR-92a expression in the equine chondrocytes. There was a significant (p<0.05) increase in COMP, COL3A1 and Sox9 in the miR-92a mimic treatment and there was no difference in ADAMTS-5 expression between the miR-92 mimic and inhibitor treatment.

RNA-seq demonstrated miR-92a was downregulated in severe OA synovial fluid samples which has not previously been reported in horses, however miR-92a is known to play a role in the pathogenesis of OA in other species. Over expression of miR-92a in equine chondrocytes led to significantly increased COMP and Sox9 expression, consistent with a chondrogenic phenotype which has been identified in human and murine chondrocytes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 92 - 92
23 Feb 2023
Lee S Lin J Lynch J Smith P
Full Access

Dysmorphic pelves are a known risk factor for malpositioned iliosacral screws. Improved understanding of pelvic morphology will minimise the risk of screw misplacement, neurovascular injuries and failed fixation. Existing classifications for sacral anatomy are complex and impractical for clinical use. We propose a CT-based classification using variations in pelvic anatomy to predict the availability of transosseous corridors across the sacrum. The classification aims to refine surgical planning which may reduce the risk of surgical complications.

The authors postulated 4 types of pelves. The “superior most point of the sacroiliac joint” (sSIJ) typically corresponds with the mid-lower half of the L5 vertebral body. Hence, “the anterior cortex of L5” (L5a) was divided to reference 3 distinct pelvic groups. A 4th group is required to represent pelves with a lumbosacral transitional vertebra. The proposed classification:

A – sSIJ is above the midpoint of L5a

B – sSIJ is between the midpoint and the lowest point of L5a

C – sSIJ is below the lowest point of L5a

D – pelves with a lumbosacral transitional vertebra

Specific measures such as the width of the S1 and S2 axial and coronal corridors and the S1 lateral mass angles were used to differentiate between pelvic types.

Three-hundred pelvic CT scans were classified into their respective types. Analysis of the specific measures mentioned above illustrated the significant difference between each pelvic type. Changes in the size of S1 and S2 axial corridors formed a pattern that was unique for each pelvic type. The intra- and inter-observer ratings were 0.97 and 0.95 respectively.

Distinct relationships between the sizes of S1 and S2 axial corridors informed our recommendations on trans-sacral or iliosacral fixation, number and orientation of screws for each pelvic type. This classification utilises variations in the posterior pelvic ring to offer a planning guide for the insertion of iliosacral screws.


Aims

There are concerns regarding nail/medullary canal mismatch and initial stability after cephalomedullary nailing in unstable pertrochanteric fractures. This study aimed to investigate the effect of an additional anteroposterior blocking screw on fixation stability in unstable pertrochanteric fracture models with a nail/medullary canal mismatch after short cephalomedullary nail (CMN) fixation.

Methods

Eight finite element models (FEMs), comprising four different femoral diameters, with and without blocking screws, were constructed, and unstable intertrochanteric fractures fixed with short CMNs were reproduced in all FEMs. Micromotions of distal shaft fragment related to proximal fragment, and stress concentrations at the nail construct were measured.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 142 - 142
1 Nov 2021
Negri S Wang Y Lee S Qin Q Cherief M Hsu GC Xu J Tower RJ Levi B Levin A James A
Full Access

Introduction and Objective

Heterotopic ossification is the formation of extraskeletal mineralized tissue commonly associated with either trauma or surgery. While several mouse models have been developed to better characterize the pathologic progression of HO, no model currently exists to study HO of the hip, the most common location of acquired HO in patients. Owing to the unique biological mechanisms underpinning the formation of HO in different tissues, we sought to develop a model to study the post-surgical HO of the hip.

Materials and Methods

Wild-type mice C57BL/6J mice were used to study the procedure outcomes, while Pdgfra-CreERT2;mT/mG and Scx-GFP reporter animals were used for the lineage tracing experiments (total n=16 animals, male, 12 weeks old). An anterolateral approach to the hip was performed. Briefly, a 2 cm incision was made centered on the great trochanter and directed proximal to the iliac crest and distally over the lateral shaft of the femur. The joint was then reached following the intermuscular plane between the rectus femoris and gluteus medius muscles. After the joint was exposed, the articular cartilage was removed using a micropower drill with a 1.2 mm reamer. The medius gluteus and superficial fascia were then re-approximated with Vicryl 5-0 suture (Ethicon Inc, Somerville, NJ) and skin was then closed with Ethilon 5-0 suture (Ethicon Inc). Live high resolution XR imaging was performed every 2 wks to assess the skeletal tissues (Faxitron Bioptics, Tucson, AZ). The images were then scored using the Brooker classification. Ex-vivo microCT was conducted using a Skyscan 1275 scanner (Bruker-MicroCT, Kontich, Belgium). 3D reconstruction and analysis was performed using Dragonfly (ORS Inc., Montreal, Canada). For the histological analysis of specimens, Hematoxylin and Eosin (H&E), modified Goldner's Trichrome (GMT) stainings were performed. Reporter activity was assessed using fluorescent imaging.


Bone & Joint Research
Vol. 10, Issue 4 | Pages 250 - 258
1 Apr 2021
Kwak D Bang S Lee S Park J Yoo J

Aims

There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning.

Methods

In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1349 - 1353
3 Oct 2020
Park CH Song K Kim JR Lee S

Aims

The hypothesis of this study was that bone peg fixation in the treatment of osteochondral lesions of the talus would show satisfactory clinical and radiological results, without complications.

Methods

Between September 2014 and July 2017, 25 patients with symptomatic osteochondritis of the talus and an osteochondral fragment, who were treated using bone peg fixation, were analyzed retrospectively. All were available for complete follow-up at a mean 22 of months (12 to 35). There were 15 males and ten females with a mean age of 19.6 years (11 to 34). The clinical results were evaluated using a visual analogue scale (VAS) and the American Orthopaedic Foot and Ankle Society (AOFAS) score preoperatively and at the final follow-up. The radiological results were evaluated using classification described by Hepple et al based on the MRI findings, the location of the lesion, the size of the osteochondral fragment, and the postoperative healing of the lesion.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 35 - 35
1 Apr 2018
Ko J Wang F Lee S Siu K Chou W Wang C
Full Access

Introduction

Blood loss after TKA varied, but not uncommon with up to 1500 ml or a decrease in hemoglobin of 3–4 g/dL. In addition to improving prosthetic alignment, computer-assisted TKAs also contribute to reduced operative blood loss and systemic emboli. These observations imply that navigation TKAs may cause less microvascular endothelial damage than conventional TKAs. Cell adhesion molecules (CAMs) have been employed as markers for endothelial or vascular damage. We hypothesized serum levels of CAMs in patients receiving navigation TKAs may be different from those receiving conventional TKAs.

Material and Methods

A prospective comparative study, enrolling 87 patients with osteoarthritic knees was conducted. There were 54 navigation TKAs and 33 conventional TKAs. Levels of cell adhesion molecules (CAM) in sera and hemovac drainage were measured by ELISA before and 24 hours after the surgery. Hb and Ht were checked pre- and post-operatively. The blood loss was calculated though the formula by Nadler and Sehat et al.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 26 - 26
1 Apr 2018
Yoon P Kim C Park J Lee S Yoon K
Full Access

Background

A stem sitting proud (SP) or that above the final rasp position remains in some patients who undergo hip replacement using proximally coated tapered wedge stems. Surgeons may face challenges providing the best fit due to unpredictable stem seating. Zimmer Inc. introduced a new rasp to solve this issue but the clinical results of this rasp have not yet been published. Therefore, we aimed to address the following: 1) What is SP incidence using a proximally coated cementless tapered wedge stem? 2) Does the new rasp system improve seating height? 3) What are the risk factors of SP?

Methods

We performed a retrospective study with 338 hips, in which Tri-Lock Bone Preservation Stem (BPS) was used in 181 and M/L Taper stem was used in 157 hips (82 hips before and 75 hips after the new rasp). A positive stem SP was defined as a stem proud height of >2 mm. We analyzed and compared SP incidence in two stems and in M/L Taper stems before and after the new rasp use.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 1 - 1
1 Apr 2018
Jo S Lee S Lim W Kim D Lee J
Full Access

Introduction

Cobalt chrome femoral head has been used widely in total hip arthroplasty and has shown favorable outcome. However, there is still of concern of potential metal toxicity from the wear debris. In the other hand, titanium is well known for its biocompatibility but it is not used in bearing surface of arthroplasty due to its brittleness. Recently, coating of the prosthesis using plasma electrolytic oxidation (PEO) has shown favorable surface protection. Thus, in this study, we tried to find out whether the PEO coating on the titanium surface would provide surface protection.

Materials and methods

Five Titanium alloy (Ti-6Al-4V) ball mimicking femoral head was manufactured and was coted using plasma electrolytic oxidation. Wear rate was tested using validated wear tester with 10N compression force at 80rpm. The amount of wear was detected by measuring change of weight after wear test was completed. This was compared with femoral head manufactured with titanium alloy without PEO coating. Toxicity of the debris was also tested using MTT assay with human osteoblast cell line.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 2 - 2
1 Apr 2018
Jo S Lee S Kang S
Full Access

Introduction

The correct anteversion of the acetabular cup is critical to achieve optimal outcome after total hip arthroplasty. While number of method has been described to measure the anteversion in plane anteroposterior and lateral radiograph, it is still controversial which method provides best anteversion measurement. While many of the previous studies used CT scan to validate the anteversion measured in plane anteroposterior radiograph, this may cause potential bias as the anteversion measured in CT scan reflects true anteversion while the anteversion measurement methods in plane radiograph are design to measure the planar anteversion. Thus, in the current study, we tried to find the optimal anteversion measurement method free from the previously described bias.

Material and method

Custom made cup model was developed which enables change in anteversion and inclination. Simple radiograph was taken with the cup in 10° to 70° degree of inclination at 10° increments and for each inclination angle, anteversion was corrected from 0° to 30° at 5° increments. The radiograph was taken with the beam directed at the center of the cup (mimicking hip centered anteroposterior radiograph) and at 9cm medial to the cup (mimicking pelvis anteroposterior radiograph). The measurements were done by two orthopaedic surgeons using methods described by 1) Pradhan et al, 2) Lewinak et al, 3) Widmer et al, and 4) Liaw et al. For each measurements, the anteversion were compared with the actual anteversion.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 111 - 111
1 Mar 2017
Kim J Jeong H Lee S Kim H Yoo J
Full Access

Clinical and radiological results of total hip arthroplasty (THA) using proximally coated single wedge (PSW) cementless stems are generally excellent. The geometry of cementless stems and the morphology of proximal femurs (Dorr types) provide optimal fit for primary stability and secondary biologic fixation. Because the geometry of PSW shape is designed to be engaged at the metaphysis, cementless PSW stem is not traditionally recommended to Dorr type C femurs with concerns of inadequate implant-host bone contact and the risk of femoral fracture. Nevertheless, previous studies on PSW cementless stems have not examined long-term survivorship according to Dorr types of femur. Paucity of a long-term comparative study makes it difficult to know whether the PSW stem plays a role in Dorr type C femurs or not. We postulated that the PSW stem could achieve stable fixation without increased risk of femoral fracture even in Dorr type C femurs, and demonstrate acceptable long-term results. The aim of this study was to investigate differences of clinical and radiological outcomes of THA using PSW stem according to proximal femoral geometry (Dorr types) in more than a 10-year follow-up.

Three hundred and seven primary THA in 247 patients, which was performed with use of a single-designed PSW stem from 1997 to 2003 and was followed up for over 10 years, were included in this retrospective study. According to Dorr's criteria, 89 femora were classified as Type A, 156 as Type B, and 62 as Type C. The patients' mean age at operation was 43.2 years (range, 18.4 – 69.6 years). They were followed-up for an average of 13.2 years (the range, 10.0 – 17.3 years). All of the hips were evaluated clinically and radiologically with special attention to the occurrence of implant loosening and periprosthetic femoral fracture.

The mean preoperative Harris hip score (50.4±20.6 points) improved significantly to 95.6±9.0 points at the final follow-ups. The improvements were observed regardless of Dorr types (p<0.001 in all 3 groups). The incidence of thigh pain (p=0.704) was not significantly different among groups. Implant survivorship was 100% in all 3 groups. None of the stems were loosened or revised. No significant differences were observed in osteolysis (p=0.492), pedestal formation (p=0.323), or cortical hypertrophy (p=0.169) among the groups [Fig. 1]. Radiolucent lines less than 2mm in thickness in Gruen zone 4 were observed more in Dorr type C femora than in Dorr type A or B (p=0.003) [Fig. 2]. Spot weld (p<0.001) and stress shielding (p=0.010) of proximal femur were more pronounced in Dorr C type femora than in type A or B [Fig. 3]. The prevalence of intraoperative (p=0.550) or postoperative (p=0.600) femoral fractures were not significantly different among the groups.

From over a 10-year follow-up, the PSW stem provided excellent stem survivorship regardless of Dorr type with satisfactory outcomes. The remodeling process around the stem was more pronounced in Dorr type C femur. The present study shows that the PSW stem is a recommendable option for Dorr type C femur.

For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 114 - 114
1 Mar 2017
Yoon P Lee S Kim J Kim H Yoo J
Full Access

Alternative bearing surfaces has been introduced to reduce wear debris-induced osteolysis after total hip arthroplasty (THA) and offered favorable results. Large population-based data for total joint surgery permit timely recognition of adverse results and prediction of events in the future. The purpose of this study was to present the epidemiology and national trends of bearing surface usage in primary total hip arthroplasty (THA) in Korea using nationwide database.

A total of 30,881 THAs were analyzed using the Korean Health Insurance Review and Assessment Service database for 2007 through 2011. Bearing surfaces were sub-grouped according to device code for national health insurance claims and consisted of ceramic-on-ceramic (CoC), metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and metal-on-metal (MoM). The prevalence of each type of bearing surface was calculated and stratified by age, gender, hospital type, primary payer, and procedure volume of each hospital.

The number of primary THAs increased by 25.2% from 5,484 in 2007 to 6,866 in 2011. The average age of the entire study population was 58.1 years, and 53.5% were male [Table 1]. CoC was the most commonly used bearing surface (76.7%), followed by MoP (11.9%), CoP (7.3%), and MoM (4.1%). The distribution of bearing surfaces was identical to that in the general population regardless of age, gender, hospital type, and primary payer [Table 2]. The mean age of patients that received hard-on-hard bearing surfaces (CoC and MoM) was significantly younger than that of patients receiving hard-on-soft bearing surfaces (CoP and MoP) (56.9 years vs. 62.6 years). During the study period, 55.1% of THAs that used a hard-on-hard bearing surface were performed in males, while 53.0% of THAs that used a hard-on-soft bearing surface were performed in females. The order of prevalence of bearing surfaces was identical in low- and medium-volume hospitals (CoC was first, MoP was second, CoP was third, and MoM was fourth). The mean hospital charges did not differ according to the bearing surface used, with the exception of CoP, which was associated with a lower mean hospital charge. There were no changes in the distribution of bearing surfaces in each year between 2007 and 2011. Overall, the percentage of THAs that used CoC bearing surfaces increased substantially from 71.6% in 2007 to 81.4% in 2011, while the percentage that used CoP, MoP, and MoM decreased significantly [Fig. 1].

One of the reasons for the dominant usage of hard-on-hard bearing surfaces may be that the principal diagnosis of primary THAs and the patient age group distribution in Korea differ from those in other countries. The most common indication for primary THA is osteonecrosis of the femoral head in Korea. In contrast, the majority of primary THAs are performed for osteoarthritis in Western countries. The choice of bearing surface may be affected by many factors, including the nation's medical delivery system, payment type, disease pattern, and age distribution of patients that undergo THA. In future, the results of a large-scale nationwide study on primary THAs using CoC bearing surfaces in Korea will be reported.

For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 110 - 110
1 Mar 2017
Yoo J Lee S Kim J Seo W Kim H
Full Access

Background

A cell-based tissue-engineered construct can be employed for treating meniscal lesions occurring in the non-vascularized inner two-thirds. The objective of this study was to test the hypothesis that both pre-differentiation of human bone marrow derived stromal cells (hBMSCs) into chondrogenic lineage before cell seeding and platelet-rich plasma (PRP) pretreatment on a PLGA mesh scaffold enhances the healing capacity of the meniscus with hBMSCs-seeded scaffolds in vivo.

Methods

PRP of 5 donors was mixed and used for the experiments. The woven PLGA mesh scaffold (VicrylTM, Ethicon) measuring 20×8 mm (thickness, 0.2 mm) was prepared. The scaffolds were immersed into 1,000 μl of PRP and were centrifuged at 150g for 10 min. Then, the scaffold was flipped 180° and the same procedure was done for the other side. After washing, the scaffolds were soaked into 1,000 μl of DMEM media. hBMSCs from an iliac crest of 10 patients after informed consent and approval of our IRB were induced into chondrogenic differentiation with chondrogenic media containing 10 ng/ml rhTGF-ß3 in 1.2% alginate bead culture system for 7 days. Then, 2×105 hBMSCs were recovered, seeded onto the scaffold, and cultured under dynamic condition. Based on the presence of pre-differentiation into chondrogenic lineage and the PRP pretreatment, 4 study groups were prepared. (no differentiation without PRP, no differentiation with PRP, chondrogenic differentiation without PRP, chondrogenic differentiation with PRP) Cell number for each cell-seeded scaffold was determined at 24 hours after seeding. Then, scaffolds were placed between human meniscal discs and were implanted subcutaneously in nude mice for 6 weeks (n=10 per group).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 112 - 112
1 Feb 2017
Chun C Chun K Baik J Lee S
Full Access

Purpose

To compare and analyze the long term follow up clinical & radiological result after utilization of fixed-type & rotating-type implant for high flex both total knee replacement.

Subject & Method

This paper targeted 45 patients, 90 cases that got high flex both total knee replacement with utilization of fixed-type implant(LPS-flex®) & rotating-type implant(P.F.C® Sigma RP-F) for 1 patient by 1 operator(C.C.H) in our hospital from 2005.01 to 2006.11. Preoperative diagnoses were degenerative arthritis (43 patients, 86 cases), rheumatic arthritis (2 patients, 4 cases), mean age at the operation was 66.4 years old(54∼78), 3 men, 42 women, mean follow up period was 110.8months(97∼120). We compared and estimated Hospital for Special Surgery(HSS) score and Knee Society Score(KSS), Western Ontario and MacMaster Universities Osteoarthritis(WOMAC) score and mean range of motion of knee joint at pre-operation and last follow up for functional & clinical evaluation. And we compared and estimated change of femorotibial angle and radiolucency through erect AP & lateral x-ray at pre-, post-operation and last follow up using American Knee Society Roentgen Graphic Evaluation for radiological evaluation.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 113 - 113
1 Feb 2017
Lee S
Full Access

Objectives

The purpose of this study was to evaluate the impact of multi-radius (MR, n=20) versus gradually reducing radius (GR, n=18) knee design on the kinematics and kinetics of the knee during level ground walking one year after total knee arthroplasty.

Materials and Methods

Thirty-eight knees with end-stage knee osteoarthritis were examined before and one year after total knee arthroplasty. The groups consisted of subjects who had undergone total knee arthroplasty with a representative MR designed implant (B Braun-Aesculap Vega® Knee System) and a representative GR designed implant (Depuy Attune® Knee System) (Figure 1). The kinematic and kinetic parameters of knee varus angle, first peak knee adduction moment, sagittal plane knee excursion and extensor moment were evaluated during gait, as well as the spatiotemporal gait outcomes of walking speed, stride length, cadence, step length, the percentage of stance phase. Comparisons of preoperative and postoperative outcomes were done by the paired t-test. Independent t-test was also done to compare the postoperative outcomes of MR designed implant and GR designed implant.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 64 - 64
1 Feb 2017
Yoon P Kim C Lee S Yoo J Kim H
Full Access

Few epidemiological studies from Asian countries have addressed this issue and reported that FAI is less prevalent in Asian population. The purpose of this study was to determine the prevalence of radiographic hip abnormalities associated with FAI in asymptomatic Korean volunteers. The authors hypothesized that the prevalence of FAI in Korean population would not be less than that in western population.

Two hundred asymptomatic volunteers with no prior hip surgery or childhood hip problems underwent three-view plain radiography (pelvis anteroposterior (AP) view, Sugioka view, and 45° Dunn view) of both hips. Cam lesions were defined as the presence of the following signs on each views: pistol-grip deformity, osseous bump at the femoral head-neck junction, flattening of the femoral head-neck offset, or alpha angle >50°. Pincer lesions were determined by radiographic signs, including crossover sign, posterior wall deficient sign, or lateral center-edge (CE) angle >40°. Only positive cases agreed by both observers were defined as true FAI-related deformities.

There were 146 male and 254 female hips, with a mean age of 34.7 years. On pelvis AP view, the prevalence of pistol grip deformity, bump, flattening, and alpha angle >50° was 1.3% (male 3.4%, female 0%), 0.8% (male 2.1%, female 0%), 0.8% (male 2.1%, female 0%), and 1.0% (male 2.7%, female 0%), respectively. On Sugioka view, the prevalence of bump, flattening, and alpha angle >50° was 9.8% (male 14.4%, female 7.1%), 13.5% (male 20.5%, female 9.4%), and 14.0% (male 26.7%, female 6.7%), respectively. On 45° Dunn view, the prevalence of bump, flattening, and alpha angle >50° was 8.0% (male 14.4%, female 4.3%), 17.5% (male 27.4%, female 11.8%), and 27.5% (male 44.5%, female 17.7%), respectively. The prevalence of cam lesion which was identified on at least one radiograph was 42.5% (male 62.3%, female 31.1%). The prevalence of cam lesion which was identified on ≥2 radiographs was 19.3% (male 30.8%, female 12.6%). The prevalence of cam type FAI (at least one cam lesion) was 2.0% (male 5.5%, female 0%) on pelvis AP view, 25.8% (male 37.0%, female 19.3%) on Sugioka view, and 35.8% (male 55.5%, female 24.4%) on 45° Dunn view. On pelvis AP view, the prevalence of crossover sign, posterior wall sign, and CE angle >40° was 20.0% (male 23.3%, female 18.1%), 20.8% (male 22.6%, female 19.7%), and 2.0% (male 2.7%, female 1.6%), respectively. The prevalence of pincer type of FAI (at least one pincer lesion) was 23.0% (male 27.4%, female 20.5%).

In asymptomatic Korean volunteers, the prevalence of cam type FAI was low on AP pelvis radiographs, whereas the prevalence of cam type FAI on Sugioka and 45° Dunn view was found to be comparable to that previously reported in Western populations. The prevalence of pincer type FAI in asymptomatic Korean volunteers was also comparable that in Western populations and was similar in both gender. Considering the high prevalence of FAI morphologic features on plain radiographs in asymptomatic Korean populations, it is also important to determine whether FAI is a cause of hip pain when considering surgery in Asian patients.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 69 - 69
1 Feb 2017
Kim K Lee S
Full Access

Background

To evaluate the causes and modes of complications after unicompartmental knee arthroplasty (UKA), and to identify its prevention and treatment method by analyzing the complications after UKA.

Materials and Methods

A total of 1,576 UKAs were performed between January 2002 and December 2014 at a single-institution. Postoperative complications occurred in 89 knees (83 patients, 5.6%), and 86 of them were found in females and 3 in males. Their mean age was 61 years (range, 46 to 81 years) at the time of initial UKA and 66 years (range, 46 to 82 years) at the time of revision surgery. We analyzed the complications after UKA retrospectively andinvestigated the proper methods of treatment (Table 1).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 109 - 109
1 Feb 2017
Kim J Han H Lee S Lee M
Full Access

Background

Rotational alignment is important for the long-term success and good functional outcome of total knee arthroplasty (TKA). While the surgical transepicondylar axis (sTEA) is the generally accepted landmark on the distal femur, a precise and easily identifiable anatomical landmark on the tibia has yet to be established. Our aim was to compare five axes on the proximal tibia in normal and osteoarthritic (OA) knees to determine the best landmark for determining rotational alignment during TKA.

Methods

One hundred twenty patients with OA knees and 30 without knee OA were recruited for the study. Computed tomography (CT) images were obtained and converted through multiplanar reconstruction so the angles between the sTEA and the axes of the proximal tibia could be measured. Five AP axes were chosen: the line connecting the center of the posterior cruciate ligament(PCL) and the medial border of the patellar tendon at the cutting level of the tibia (PCL-PT), the line from the PCL to the medial border of the tibial tuberosity (PCL-TT1), the line from the PCL to the border of the medial third of the tibia (PCL-TT2), the line from the PCL to the apex of the tibia (PCL-TT3), and the AP axis of the tibial prosthesis along with the anterior cortex of the proximal tibia (anterior tibial curved cortex, ATCC).


Purpose

We aimed to investigate whether the anterior superior iliac spine could provide consistent rotational landmark of the tibial component during mobile-bearing medial unicompartmental knee arthroplasty (UKA) using computed tomography (CT).

Methods

During sagittal tibial resection, we utilized the ASIS as a rotational landmark. In 47 knees that underwent postoperative CT scans after medial UKA, the tibial component position was assessed by drawing a line tangential to the lateral wall of the tibial component. Rotation of the tibial component was measured using two reference lines: a line perpendicular to the posterior cortical rim of the tibia (angle α) and Akagi's line (angle β). Instant bearing position and posterior cruciate ligament fossa involvement were also evaluated. External rotation of the tibial component relative to each reference line and external rotation of the bearing relative to the lateral wall of the tibial component were considered positive values.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 108 - 108
1 Feb 2017
Lee S Yoon P Yoo J Kim H
Full Access

Introduction

Legg-Calve-Perthes disease (LCPD), a juvenile osteonecrosis of the femoral head (ONFH), can remain sequelae around hip joint, and results in osteoarthritis necessitating total hip arthroplasty (THA) in middle-age. THA for sequelae of LCPD needs specific concerns for anatomical deformity, leg length discrepancy (LLD), and relatively young patient's age. To date, few studies are available for the results of THA for LCPD sequelae. Moreover, there was no study for the result of Alumina-Alumina THA (Al-Al THA) in patient with LCPD sequelae, even excellent long term outcome of Al-Al THA has been documented in relatively young patients. The aim of this retrospective study is to evaluate the clinical and radiological outcome of Al-Al THA for LCPD sequelae, especially in terms of the restoration of LLD and the occurrence of complication. In addition, we compared the results of THA for LCPD sequelae with those for adult onset ONFH, in which THA is necessitated in relatively young age and excellent long term outcome has been proven after Al-Al THA.

Method

Between 1997 and 2007, 41 cementless Al-Al THA were performed in 37 patients with LCPD sequelae and followed up for mean, 10.4 years. Mean age at THA was 43.6 years. Using the propensity score matching with age, gender, and the length of follow-up as variables, 41 THAs in 37 patients were identified from 339 hips in 256 patients who underwent primary Al-Al THA for ONFH during the same period. Clinical and radiological outcomes in terms of implant survival, Harris hip score (HHS), LLD change, and perioperative complication were compared between the two groups.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 110 - 110
1 Feb 2017
Park I Lee M Chung K Kim K Lee S Im S Han H
Full Access

Buechel and Pappas invented a modified version of LCS RP system (Co-Cr) with light material (Titanium), axial rotation limiting bar and improved conformity. The purpose of this prospective randomized study was to compare the minimum 3-year clinical outcomes including lightness, preference, and instability between the Co-Cr implant system and the Titanium implant system in bilateral total knee arthroplasty.

We prospectively enrolled 108 patients and 20 patients were lost to follow-up. Therefore, 88 patients (176 knees; mean age, 69.9±6.0years) were included in the study. The range of motion and clinical scores such as Knee Society score (KSS), Hospital for Special Surgery score (HSS) and Western Ontario and McMaster University (WOMAC) scores were measured preoperatively and postoperatively. At each follow-up, patients also complete a Likert scale questionnaire regarding subjective pain, lightness, left-right side preference (naturalness and satisfaction) and subjective instability.

There were no significant differences in all preoperative variables between two groups (p>.05). Mean follow-up period was 46.3±8.8 (36 to 72) months. The mean weight of Titanium implants was three times lighter than that of Co-Cr implants (133.9g versus 390.1g, p<.01). At the minimum of 3-year follow-up, there were no significant differences in pain, range of motion (ROM), clinical scores including KSS, HSS, and WOMAC between both groups. Also, the study showed no significant differences with subjective pain, lightness, preference (convenience, naturalness, and satisfaction), and subjective instability between the Co-Cr protheses and the Titanium protheses (p>.05).

No differences in clinical outcomes as well as subjective side-to-side differences between the Co-Cr prostheses and the Titanium prostheses were observed in the minimum 3-year follow-up. This implies that patients do not feel differently with two different weighted implants in mid-term follow-up.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 111 - 111
1 Feb 2017
Chun C Chun K Baik J Lee S
Full Access

Background

This study was conducted to assess the clinical and radiologic results of total knee arthroplasty (TKA) with an allogenic bone graft using varus-valgus constrained (VVC) prostheses in knees with severe bone defects and unstable neuropathy.

Methods

This study included 20 knees of 16 patients who underwent TKA between August 2001 and January 2006 due to unstable knees with severe bone destruction resulting from neuropathic arthritis. At the time of surgery, the mean age of the patients was 56 years. The mean length of the follow-up period was 10.7 years. A VVC condylar prosthesis was used with an allogenic femoral head graft to reconstruct large bony defects. Clinical results were evaluated using the Hospital for Special Surgery (HSS), Knee Society (KS) function, and Western Ontario and McMaster Universities Osteoarthritis (WOMAC) scores. Three-dimensional computed tomography (3D-CT) was used to evaluate the radiological parameters, which included the tibiofemoral angle, loosening or osteolysis of components, and incorporation of the bone graft.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 111 - 111
1 May 2016
Park S Jeong S Lee S
Full Access

Introduction

Most surgeons that have performed kinematically aligned TKA have noticed an overall better clinical outcome, better motion, better patient satisfaction, and a quicker recovery than their patients treated with mechanically aligned TKA.

Materials and Methods

We prospectively followed all 128 knees who underwent primary total knee arthroplasty. The Lysholm knee score and VAS scale was recorded initially and 12months after the surgery. Independent T-test was used for statistical analysis at probability level of 95%. SPSS for Windows (Version 12, Chicago, Illinois) was used.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 69 - 69
1 May 2016
Jung K Kumar R Lee S Ong A Ahn H Park H
Full Access

Introduction

Positive expectations can increase compliance with treatment and realistic expectations may reduce postoperative dissatisfaction. Recently there are articles regarding expectations of patients from their TKA in western literature and only few articles based on Korean populations which don't encompass the whole spectrum of expectations in Korean patients. In all those articles based on pre-operative expectation, results were applied to whole expectation category uniformly not differentially. We aimed to document the pre-operative expectations in Korean patients undergoing total knee replacement using an established survey form and to determine whether expectations were influenced by socio-demographic factors and socio-demographic factors influences expectation items in particular category uniformly or differentially.

Methods

Expectations regarding 19 items in the Knee Replacement Expectation Survey form were investigated in 228 patients scheduled for total knee replacement. The levels and distribution patterns of individual and summated expectation of five expectation categories; relief from pain, baseline activity, high flexion activity, social activity and psychological wellbeing, constructed from the 19 items were assessed. Univariate analyses and Binary logistic regression were performed and analyzed to examine the association of expectations with the socio-demographic factors.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 70 - 70
1 May 2016
Jung K Kumar R Lee S Ahn H Gondalia V Ong A Park H
Full Access

Introduction

Unicompartmental knee arthroplasty (UKA) is becoming an increasingly popular option in single compartment osteoarthritis. As a result, diverse re-operations including revisions to total knee arthroplasty (TKA) has also increase. The objective of this study is to investigate the distribution of causes of re-operations after UKA and to analyze the types of re-operations.

Method

We retrospectively reviewed 691 UKAs performed on 595 patients between January 2003 and December 2011. Except in one case, all UKAs were performed for medial compartment osteoarthritis of the knee. The UKAs were performed in 487 (81.8%) women and 108 (18.2%) men. The mean age at the time of UKA was 61.5 years (47 to 88 years). Mobile-bearing designs were implanted in 627 (90.7%) knees (626- Oxford knee and 1- Scorpio knee) and fixed designs were implanted in 64 (9.3%) knees (42- Tornier and 18- Zimmer). The mean interval between UKA and second operation was 15.4 months (10 days to 10 years) and between second and third operation was 7.7 months (5 weeks to 17 months). In the re-operation group, there were 50 knees (48 patients) with 38 female and 10 male patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 110 - 110
1 May 2016
Park S Jeong S Lee S
Full Access

Purpose

The purpose of this study was to demonstrate postoperative improvement and high satisfaction rates after a surgical approach that includes arthroscopic labral repair only, in patients with borderline dysplasia, without instability.

Methods

Between September 2009 and December 2011, patients less than 50 years old who underwent hip arthroscopy for symptomatic intra-articular hip disorders, with a lateral center-edge (CE) angle between 20 and 25, were included in this study. Patients with Tönnis grade 2 or greater, hip joint space narrowing, severe hip dysplasia, hip joint instability and Legg-Calve-Perthes disease were excluded. Patient-reported outcome scores, including the modified Harris Hip Score (mHHS), Western Ontario and McMaster Universities Arthritis index (WOMAC), and visual analog scale (VAS) for pain were obtained in all patients preoperatively and at 1, 2, and 3 years postoperatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 146 - 146
1 May 2016
Lee S Wang L
Full Access

Objectives

To evaluate the clinical and radiographic outcomes of total knee arthroplasty using Vega® Knee System (B Braun-Aesculap, Tuttlingen, Germany) [Fig. 1] designed to allow high flexion by shortening the length of posterior condylar flange of femoral component after at least 2 year and to assess the occurrence of periprosthetic osteolysis and loosening at final follow-up.

Materials and Methods

Of the patients who underwent total knee arthroplasty using Vega® Knee System between April 2011 and May 2013, 40 patients (46 knees) were enrolled. The mean age of the patients at the time of surgery was 72.3 years and the mean follow-up period was 29.4 months. Clinical parameters, including Knee Society Knee score, Knee Society Function score, maximal flexion and range of motion were evaluated. Relationship between postoperative maximal flexion and radiographic factors including the posterior tibial slope, the femoral condylar offset and the change of the posterior flange length of femoral condyle was analyzed. Also, the occurrence of periprosthetic osteolysis and loosening was assessed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 96 - 96
1 May 2016
Kim K Lee S Kim J Shin W
Full Access

Background

In this study, we investigated the long-term clinical results and survivorship of minimally invasive unicompartmental knee arthroplasty (UKA) by collecting cases that have been implanted for >10 years ago.

Methods

Medial UKA on 180 cases in 142 patients was performed over a period of 1 year after the first introduction of minimally invasive UKA from January 2002 to December 2002. Among these, 166 cases in 128 patients who underwent Oxford phase 3 medial UKA using the minimally invasive surgery, with the exclusion of 14 cases including 10 cases of follow-up loss and 4 cases of death, were selected as the subject. The mean age of the patients at the time of surgery was 61 years, and the duration of the follow-up was minimum 10 years. All the preoperative diagnosis was osteoarthritis of the knee joint. Clinical and radiographic assessments were measured by the Knee Society clinical rating system, and the survival analysis was confirmed by the Kaplan–Meier method with 95% confidence interval (CI).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 97 - 97
1 May 2016
Kim K Lee S Kim J Ko D
Full Access

Purpose

To identify the modes of failure after total knee arthroplasty (TKA) in patients ≤ 55 years of age and to compare with those ≥ 56 years of age in patients who underwent revision TKA.

Materials and Methods

We retrospectively reviewed 256 revision TKAs among patients who underwent TKA for knee osteoarthritis between January 1992 and December 2012. The causes of TKA failure were analyzed and compared between those ≤ 55 years of age and those ≥ 56 years of age. The age at the time of primary surgery was ≤ 55 years in 30 patients (31 knees) and ≥ 56 years in 210 patients (225 knees).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 17 - 17
1 Feb 2016
Song E Seon J Lee S Seol Y
Full Access

Among many factors that influence the outcomes of Total Knee Arthroplasties (TKAs), the mechanical alignment has played major roles for the success of TKA, the survival rates of the implants, and patient functionality. Most, but not all, studies have shown that alignment of the mechanical axis in the coronal plane within a range of 3° varus/valgus is associated with improved long-term function and increased survival rates. Robot-assisted TKA has been developed to improve improves the accuracy and precision of component implantation and mechanical axis (MA) alignment. We hypothesised that robot-assisted TKA would lead to a more accurate leg alignment and component implantation, and thus, improve radiological and clinical outcomes.

Between January 2003 and December 2004, a total of 98 primary TKA procedures were compared: 49 using a robotic-assisted procedure and 49 using conventional manual techniques. The cohorts were followed for 121.2 and 119.5 months on average, respectively. Radiographic assessments of the patients were performed preoperatively and at final follow-up and made according to the Knee Society Roentgenographic Evaluation System (KSRES) which included measurements of the coronal mechanical axis and sagittal and coronal inclinations of femoral and tibial components. The radiographic measurements were made using a PACS (Picture Archiving and Communication System). Clinical assessments were performed preoperatively, and at a final follow-up date that was a minimum of postoperative nine years. The clinical results included ranges of motion (ROM), Hospital for Special Surgery (HSS) scores, Western Ontario and McMaster University (WOMAC) scores (for pain and function).

The radiographic results showed no statistical differences when comparing the means of the two groups. When considering outliers (defined as error ≥ ±3°) for the mechanical axis, femoral coronal and sagittal inclinations, and tibial coronal and sagittal inclinations, the ROBODOC group had zero outliers for all measurements except for one in tibial sagittal inclination. On the other hand, the conventional group had 12 outliers for mechanical axis, 2 for femoral coronal inclination, 3 for femoral sagittal inclination, 3 for tibial coronal inclination, and 4 for tibial sagittal inclination. However, there were no statistically significant differences between groups for ROM, HSS, or WOMAC scores at the final follow-up.

The results of this study support previous work and demonstrate that the ROBODOC-assisted implantation of TKA results in better radiographic outcomes and better ligament balance with equivalent safety when compared to conventional TKA at a minimum follow-up of nine years.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 146 - 146
1 Jan 2016
Lee MC Lee S Park IW Ro DH Kim KB Chung KY Seong SC
Full Access

Purpose

Although the use of stems in revision total knee arthroplasty (RTKA) enhances survival by improving the stability of implant, questions as to the optimal fixation method as well as the vertical extent of the cement, remain unanswered. This study aimed 1) to determine the correlation between the vertical extent of cement and implant loosening; and 2) to determine the minimum cementing extent for a stable implant in revision TKA with a hybrid technique.

Materials and Methods

We retrospectively analyzed 109 stemmed RTKAs with average follow-up of 63 months. In each case, a single varus-valgus constrained implant was used and fixed with a hybrid technique. During surgery, stem was partially covered with cement beyond stem-implant junction. Stability of implant was evaluated according to the modified Knee Society Radiographic Scoring System. Cementing extent was defined as length from implant base to the end of the radiopaque line around the stem. The correlation between the vertical cementing extent and implant stability was analyzed, and the minimal vertical cementing extent for a stable implant was evaluated with a scatter plot.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 112 - 112
1 Jan 2016
Park IW Im SH Kim KB Chung KY Lee S Seong SC Lee MC
Full Access

Over the past twenty years, the Low Contact Stress Rotating Platform (LCS RP) showed good results. Buechel and Pappas invented the Buechel-Pappas Knee (B-P Knee) system that is a modified version of the LCS system with different material (titanium), axial rotation limiting bar and improved conformity. The purpose of this prospective randomized study was to compare the 2-year clinical outcomes between two implants in the same patients who had been operated with bilateral TKAs. We prospectively enrolled 107 patients and 18 patients were lost to follow-up. Therefore, 89 patients (178 knees; mean age, 69.8±6.0years) were included in the study. The range of motion and clinical scores such as Knee Society score (KSS), Hospital for Special Surgery score (HSS) and Western Ontario and McMaster University (WOMAC) scores were measured preoperatively and postoperatively. At each follow-up, patients also complete a Likert scale questionnaire regarding subjective pain, lightness, left-right side preference (naturalness and satisfaction) and subjective instability. There were no significant differences in all preoperative variables between the two groups(P<.05). Mean follow-up period was 29.9±7.2 months. At the 2-year follow-up, mean value of flexion contracture, further flexion and range of motion were not significantly different between both groups. Also, there were no significant differences in the clinical scores and in side to side difference for the feeling of laterality between two groups(P<.05). After minimum 2-year follow-up, we found no differences in early clinical outcomes as well as subjective side to side difference between the LCS RP and B-P Knee system in this study.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 15 - 15
1 Dec 2015
Chang Y Lee S
Full Access

This study aimed to determine the optimal formulation of antibiotic-loaded bone cement (ALBC) for periprosthetic joint infection (PJI) using both in vitro and in vivo models incorporating various combinations of gram-positive and gram-negative antibiotics.

The in vitro antibiotic release characteristics and antibacterial capacities of ALBCs loaded with either 4 g of vancomycin or teicoplanin and 4 g of ceftazidime, imipenem, or aztreonam were measured against methicillin-susceptible S. aureus, methicillin-resistant S. aureus, coagulase-negative staphylococci, Pseudomonas aeruginosa and Escherichia coli. ALBC spacers with superior in vitro antibacterial capacity were then implanted into ten patients (five females and five males between 29 and 75 years of age) diagnosed with chronic hip/knee PJIs and antibacterial activities within joint fluid were measured. The average duration of ALBC spacer implantation was 80 days (range, 36–155 days). Antibiotic concentrations and antibacterial activities of joint fluid at the site of infection were measured during the initial period as well as several months following spacer implantation.

Cement samples loaded with vancomycin/ceftazidime or teicoplanin/ceftazidime exhibited equal or longer antibacterial duration against test bacteria as compared with other ALBCs. Joint fluid samples exhibited antibacterial activity against the test microorganisms including ATCC strains and clinically isolated strains. There were no adverse systemic effects, infection at second stage re-implantation, or recurrent infection at final follow-up.

Vancomycin/ceftazidime ALBC provided broad antibacterial capacity both in vitro and in vivo and was shown to be an effective and safe therapeutic measure in the treatment of hip/knee PJIs.

We thank H.Y. Hsu for performing bioassay.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 14 - 14
1 Dec 2015
Lee S Hu C Chang Y
Full Access

The objective of this study was to compare the elution characteristics, antimicrobial activity and mechanical properties of antibiotic-loaded bone cement (ALBC) loaded with powdered antibiotic, powdered antibiotic with inert filler (xylitol), or liquid antibiotic, particularly focusing on vancomycin and amphotericin B.

Cement specimens loaded with 2 g of vancomycin or amphotericin B powder (powder group), 2 g of antibiotic powder and 2 g of xylitol (xylitol group) or 12 ml of antibiotic solution containing 2 g of antibiotic (liquid group) were tested.

Vancomycin elution was enhanced by 234% in the liquid group and by 12% in the xylitol group compared with the powder group. Amphotericin B elution was enhanced by 265% in the liquid group and by 65% in the xylitol group compared with the powder group. Based on the disk-diffusion assay, the eluate samples of vancomycin-loaded ALBC of the liquid group exhibited a significantly larger inhibitory zone than samples of the powder or the xylitol group. Regarding the ALBCs loaded with amphotericin B, only the eluate samples of the liquid group exhibited a clear inhibitory zone, which was not observed in either the xylitol or the powder groups. The ultimate compressive strength was significantly reduced in specimens containing liquid antibiotics.

Adding vancomycin or amphotericin B antibiotic powder in distilled water before mixing with bone cement can significantly improve the efficiency of antibiotic release than can loading ALBC with the same dose of antibiotic powder. This simple and effective method for preparation of ALBCs can significantly improve the efficiency of antibiotic release in ALBCs.

We thank H.Y. Hsu for performing the bioassay.


The aim was to compare the efficacy of selective ultrasound-screening (SUSS) for developmental dysplasia of the hip (DDH) to clinical screening alone, by comparing outcomes in a contemporary group with those from a 40 year old cohort.

This was a retrospective cohort study. The department's DDH and surgical databases were used to identify all cases of DDH, and all cases of surgery for DDH during the study period (2009–13). Patients born outside our region, and teratologic cases were excluded from analysis. The Obstetric database provided the total number of live births over the five-year period. This data was used to calculate the incidence of late-diagnosis (age over 3 months) DDH and the rate of surgery for DDH in our region. These results were compared to those of a similar study from our institution published in 1977, after the introduction of universal clinical screening. Relative risk (RR) was calculated for the two groups, and analysed for statistical significance.

The incidence of late-diagnosis DDH over the recent 5-year study period was 0.66/1000 live births, compared to 0.6/1000 in the control group. The RR for late-diagnosis DDH was not significantly different between the two groups (RR 1.14, 95% CI 0.6 to 2.2). The rate of surgery for DDH was 0.86/1000, compared to 0.9/1000 live births in the control group. The RR for surgery for DDH in the current study population compared to the historic control was 0.97, but this difference was not statistically significant (95% C.I. 0.57 to 1.68; p=0.92).

Despite advances in screening for DDH over the last 40 years, neither the incidence of late diagnosis DDH, nor rates of surgery for DDH in our region have changed. Whilst previous studies have demonstrated that SUSS does not eliminate late-presenting DDH, this study suggests it confers no advantage over clinical screening alone.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 350 - 350
1 Jul 2014
Lee S Okumachi E Dogaki Y Niikura T Iwakura T Waki T Nishida K Kurosaka M
Full Access

Summary Statement

Low-intensity pulsed ultrasound (LIPUS) enhanced osteogenic differentiation of osteoprogenitor cells derived from mouse induced pluripotent cells (iPSCs) without embryoid body formation. Our findings provide insights on the development of LIPUS as an effective technology for bone regeneration strategies using iPSCs.

Introduction

iPSCs represent a promising cell source for regenerative medicine such as bone regeneration because of their unlimited self-renewal property and ability of differentiation into all somatic cell types. Recently, we developed an efficient protocol for generating a highly homogeneous population of osteoprogenitor cells from embryonic stem cells by using a direct-plating method without EB formation step. It is well-recognised that LIPUS accelerates the fracture healing. There have been several reports showing that LIPUS stimulates the osteogenic differentiation of mesenchymal stem cells (MSCs) in vitro. To date, effect of LIPUS on iPSCs remains unknown. In this study, we investigated in vitro effect of LIPUS on osteogenic differentiation of osteoprogenitor cells derived from mouse iPS cells via a direct-plating method.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 649 - 656
1 May 2013
Park C Jang J Lee S Lee W

The purpose of this study was to compare the results of proximal and distal chevron osteotomy in patients with moderate hallux valgus.

We retrospectively reviewed 34 proximal chevron osteotomies without lateral release (PCO group) and 33 distal chevron osteotomies (DCO group) performed sequentially by a single surgeon. There were no differences between the groups with regard to age, length of follow-up, demographic or radiological parameters. The clinical results were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring system and the radiological results were compared between the groups.

At a mean follow-up of 14.6 months (14 to 32) there were no significant differences in the mean AOFAS scores between the DCO and PCO groups (93.9 (82 to 100) and 91.8 (77 to 100), respectively; p = 0.176). The mean hallux valgus angle, intermetatarsal angle and sesamoid position were the same in both groups. The metatarsal declination angle decreased significantly in the PCO group (p = 0.005) and the mean shortening of the first metatarsal was significantly greater in the DCO group (p < 0.001).

We conclude that the clinical and radiological outcome after a DCO is comparable with that after a PCO; longer follow-up would be needed to assess the risk of avascular necrosis.

Cite this article: Bone Joint J 2013;95-B:649–56.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 32 - 32
1 Apr 2013
Lee S Niikura T Koga T Dogaki Y Okumachi E Waki T Kurosaka M
Full Access

Introduction

Low-intensity pulsed ultrasound (LIPUS) has been reported to enhance healing of fracture and nonunion. Bone morphogenetic protein-7 (BMP-7) has also been reported to promote bone formation. Recently, we demonstrated progenitor cells with osteogenic/chondrogenic differentiation potential existed in human fracture hematoma and nonunion tissue.

Hypothesis

We hypothesised the combined application of LIPUS and BMP-7 would cause major effect on osteogenesis of hematoma-derived cells (HCs) and nonunion tissue-derived cells (NCs).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 56 - 56
1 Apr 2013
Dogaki Y Niikura T Lee S Koga T Okumachi E Waki T Kurosaka M
Full Access

Introduction

Our previous study using microarray analysis showed that Rad (Ras associated with diabetes) was highly expressed in nonunion. The purpose of this study is to investigate the gene expression and immunolocalization of Rad, and other Ras-related G proteins: Rem1 and Rem2 in fracture/nonunion site using rat experimental models.

Hypothesis

We hypothesized that Rad had a significant role in nonunion formation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 80 - 80
1 Apr 2013
Dogaki Y Lee S Niikura T Koga T Okumachi E Waki T Kakutani K Nishida K Kurosaka M
Full Access

Introduction

iPSCs represent a promising cell source for bone regeneration. To generate osteoprogenitor cells, most protocols use the generation of embryoid bodies (EBs). However, these protocols give rise to heterogeneous population of different cell lineage.

Hypothesis

We hypothesized that a direct plating method without EB formation step could be an efficient protocol for generating a homogeneous population of osteoprogenitor cells from iPSCs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 82 - 82
1 Apr 2013
Dogaki Y Lee S Niikura T Koga T Okumachi E Waki T Kurosaka M
Full Access

Introduction

Parathyroid hormone 1–34 (PTH) has been reported to accelerate fracture healing. Previously, we demonstrated human fracture hematoma contained osteo-/chondro-progenitor cells. To date, there has been no study investigating the effect of PTH on fracture hematoma-derived cells (HCs) in vitro.

Hypothesis

We hypothesized PTH treatment affected osteogenesis and chondrogenesis of HCs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 268 - 268
1 Mar 2013
Moon Y Seo J Kim S Jang S Lee S
Full Access

Background and Purpose

Soft-tissue balancing is crucial in total knee arthroplasty, but proper release of medial collateral ligament is a challenging procedure. It has been well recognized that medial gap tends to be more tight than lateral gap in varus knees after surgery. The purpose of this study is to investigate the incidence and predictable factors of medial tibial bone remodeling following navigation-assisted total knee arthroplasty.

Materials and methods

One hundred and sixty-six consecutive patients (221 knees) who underwent navigation-assisted total knee arthroplasty and followed during a minimum of 1 year were included in this study. Radiographic examination including anteroposterior and lateral view of both knees were performed at a regular follow-up schedules of 6 weeks, 3 months, 6 months, 1 year and thereafter, annually after surgery. An independent investigator identified the presence of medial tibial bone remodeling at each follow-up. All information on potential factors affecting medial tibial remodeling were retrieved and classified into 2 types (patient- and surgery-related).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 566 - 566
1 Sep 2012
Lee MC Lee JK Seong SC Lee S Jang J Lee SM Shim SH
Full Access

Summary

Revision TKA using CCK prosthesis showed comparable outcome to PS prosthesis in clinical and radiological results.

Introduction

In revision total knee arthroplasty (TKA), the goal should be to obtain good motion, function and most importantly stability. The stability depends on remaining soft tissue and implant design. The more the ligaments retain function, the less the implant constraint is needed to achieve stability. With increased constraint, the transfer of joint reaction forces to implant-bone interface may lead to mechanical loosening of the implant. Constrained condylar knee (CCK) prosthesis provides more constraint compared with posterior stabilized (PS) prosthesis. The purpose of this study was to compare the clinical, radiological outcome and survivorship of CCK and PS prosthesis in revision TKA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 518 - 518
1 Sep 2012
Lee C Itoi E Kim S Lee J Jung K Lee S Suh K
Full Access

Introduction

Many literatures regarding more specific tests to diagnose the supraspinatus tendon injuries and the best rehabilitation methods to strengthen the supraspinatus have been published. However, conflicting results have been reported. 2-deoxy-2-[18F] fluoro-D-glucose (FDG) positron emission tomography (PET) has been recently used to assess skeletal muscle activities in various fields.

Purpose

To evaluate & compare the metabolic activities of deltoid & rotator cuff muscles after the full-can & empty-can exercises using PET-CT.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 39 - 39
1 Sep 2012
Lee MC Lee SM Seong SC Lee S Jang J Lee JK Shim SH
Full Access

Summary

UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA.

Introduction

Recently highly conforming ultracongruent TKA has been reintroduced with improved wear characteristics and lower complications. The purpose of the study was to assess kinematics and clinical outcome of posterior stabilized and ultracongruent rotating-platform mobile bearing TKA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIII | Pages 17 - 17
1 Jul 2012
Murray O Lee S Mckenna R Kelly M Roberts J
Full Access

Early failure of metal-on-metal (MoM) total hip replacements (THR) is now well established. We review 93 consecutive patients with CPT¯ stems MoM THR. Our series demonstrates a new mechanism of failure, which may be implant combination specific.

Between January 2005 and June 2009, 93 consecutive MoM total hip replacements were preformed using CPT stems by 3 surgeons at our unit. 73 CPT¯ stems, Metasul¯ Large Diameter Heads (LDH) with Durom¯ acetabulae and 20 CPT¯ stems, Metasul¯ 28mm diameter heads in Allofit¯ shells (zimmer). Clinical outcomes were collected prospectively before surgery, at 3 months, 1 year, 2 years, 3 years, and at 5 years post surgery. Revision for any cause was taken as the primary endpoint and the roentgenograms and explanted prostheses were analyzed for failure patterns.

In the LDH/Durom¯ group a total of 13 (18%) patients required revision (figs. 1) at a median of 35 months (range 6-44). 6 (8%) for periprosthetic fracture. All 6 periprostethic fractures were associated with minimal or no trauma and all had ALVAL identified histologically.

To date there have been no failures in the CPT¯/28mm head Allofit¯ group. Several failures demonstrated bone loss in Gruen zones 8 ± 9 ± 10 (fig. 2).

We demonstrate an unacceptably high rate of failure in CPT¯ MoM LDH hip replacements, with a high failure secondary to periprosthetic fracture and postulate a mechanism associated with local toxicity to metal ions. We strongly advise against this combination of prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 656 - 659
1 May 2012
Hwang B Yoon J Nam C Jung K Lee S Han C Moon S

We retrospectively reviewed 30 two-stage revision procedures in 28 patients performed for fungal peri-prosthetic joint infection (PJI) after a primary total knee replacement. Patients were followed for at least two years or until the infection recurred. The mean follow-up for patients who remained free of infection was 4.3 years (2.3 to 6.1). Overall, 17 patients were assessed as American Society of Anesthesiologists grade 3 or 4. The surgical protocol included removal of the infected implant, vigorous debridement and insertion of an articulating cement spacer. This was followed by at least six weeks of antimicrobial treatment and delayed reimplantation in all patients. The mean interval between removal of the prosthesis and reimplantation was 9.5 weeks (6 to 24). After reimplantation, patients took antifungal agents orally for a maximum of six months. Two knees became reinfected at one and two months post-operatively, respectively: one of these subsequently required arthrodesis because of uncontrolled infection.

Fungal PJIs can be treated successfully by removal of all infected material, appropriate antimicrobial treatment and delayed reimplantation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 145 - 145
1 May 2011
Kelly J O’Briain D Walls R Lee S O’Rourke A Mc Cabe J
Full Access

Background: MRSA is a major economic and health issue in Ireland and as such is of particular importance in the appropriate management of orthopaedic patients. Bone, joint and implant infection can lead to unfavourable outcomes with a long protracted in hospital stay inevitable. The cost for the patient, the hospital and society are substantial. Numerous protocols have been proposed internationally to aid in the management of MRSA infection in orthopaedic patients with pre assessment and ring fencing of patients shown to have a favourable impact.

Aims: To analyse the impact of a series of infection control measures on the infection and prevalance of MRSA in both elective and trauma orthopaedic patients.

Methods: We conducted a prospective study of our unit over three time points from 2005 to 2008. All elective and trauma orthopaedic surgery was based in Merlin Park Hospital up until December 2006. Since then all elective orthopaedic surgery has remained based in Merlin Park Hospital with all trauma surgery being moved to University Hospital Galway and all trauma patients based in an exclusively ring fenced orthopaedic ward. We recorded total rates of MRSA infection and colonisation in all orthopaedic patients over nine months of each year from 2005 to 2008, pre and post separation of trauma and elective services. Of note a pre admission screening protocol was implemented in March of 2006. We also prospectively recorded all MRSA data in patients treated through our ring fenced trauma ward from its opening date in November 2006.

Results: 12259 patients were reviewed between 2005 and 2008. The mean age of all admitted patients was 46 with th emean age of all MRSA positiv epatients being 71(p=0.000). There was no statistical difference for gender distribution between MRSA positive patients, but more women were positive than men.

The rates of MRSA infection for 2005, 2006 and 2007 were 0.49%, 0.28% and 0.24% respectively (binomial comparison, 2005 to 2006, p< 0.005 and 2005 to 2007, p< 0.005). Again when trauma and elective units were seperated there was a corrected rate of infection of 0.14% and 0.33% respectively. In 2005 there was 9 Superficial Incisional (SI), 8 Organ Space Infection(OSI) and 4 Deep Incisional (DI), 2006 had 7 SI, 4 OS and 4 DI and in 2007 there was 9 SI, 9 OS and 1 DI seen in the elective unit There was no Deep MRSA infection seen in the new ring fenced trauma unit. MRSA infection was found to cause a considerable increase in length of stay with normal orthopaedic patients staying a mean of 5 days whilst MRSA patients staying 23.4 days (p=0.000).

Conclusion: The separation of emergency and elective orthopaedic services coupled with effective preoperative screening has resulted in a reduction of MRSA infection and improved patient outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 537 - 541
1 Apr 2011
Song WS Kong C Jeon D Cho WH Kim JR Lee S

The use of allografts for the treatment of bone tumours in children is limited by nonunion and the difficulty of finding a suitable graft. Furthermore, appositional growth can’t be expected of an allograft.

We used an overlapping allograft in 11 children, with a mean age of ten years (4 to 15), with a mean follow-up of 24.1 months (20 to 33). There were five intercalary and six intra-articular resections, and the tumours were in the femur in six cases and the humerus in five. Rates of union, times to union, remodelling patterns and allograft-associated complications were evaluated.

No allograft was removed due to a complication. Of the 16 junctional sites, 15 (94%) showed union at a mean of 3.1 months (2 to 5). Remodelling between host and allograft was seen at 14 junctions at a mean of five months (4 to 7). The mean Musculoskeletal Tumor Society score was 26.5 of 30 (88.3%). One case of nonunion and another with screw protrusion required re-operation.

Overlapping allografts have the potential to shorten time to union, decrease rates of nonunion and have positive appositional growth effect.


The minimal invasive total knee arthroplasty has demonstrated shorter hospital stays, less postoperative blood loss, and less pain associated with these techniques but concerns are raised about inaccurate implant alignment due to limited visibility. The combination of computer assisted arthroplasty and MIS could aid in the improvement of the accuracy of implantation.

This prospective randomized study presents the initial results of the first 25 cases of two different imageless computer-assisted arthroplasty, the Orthopilot(B. Braun-Aesculap, Tuttlingen, Germany) and the Ci navigation system(DePuy, Munich, Germany). The same surgeon performed all TKA procedures using the minimidvastus approach. Coronal and sagittal alignments of the femoral and tibial components were determined using postoperative full length radiographs.

Comparison of the 2 groups demonstrated no difference in postoperative limb alignment, femoral and tibial coronal alignment, and sagittal tibial alignment. The sagittal alignment between the 2 groups showed different results. The Orthopilot group showed a tendency toward flexion of the femoral components, and the Ci navigation group showed a tendency toward extension of the femoral components. The tourniquet time was longer by an average of 16minutes in the Ci navigation group. One complication of femoral fracture through the pin site occurred in the Orthopilot group. Combined CAS and MIS has he advantage in improving the accuracy of component alignment but caution is needed for improving sagittal femoral component alignment.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 122 - 122
1 Mar 2010
Lee S Seong S Kim D Lee M
Full Access

The aim of this study was to evaluate the rotational axis of the tibia and the association of its axis to tibial coronal alignment after TKR.

TKRs were performed using navigated mobile bearing system (40 knees), conventional mobile bearing (48 knees) and conventional fixed bearing (40 knees) and preoperative and postoperative CT scans were assessed using 3D image reconstruction-analysis program. The tibial AP axis which was defined as the line connecting the middle of the PCL and the medial edge of the patellar tendon attachment was measured relative to the AP axis of distal femur preoperatively and postoperatively, as well as the coronal angle of the tibia and posterior slope. The tibial coronal alignments in navigation, postoperative plain radiograph and CT were compared.

The AP axis of the tibia was in 2.10° internally rotated position relative to the AP axis of the femur preoperatively and 3.54° postoperatively (range, 19.5° internal rotation to 16.8° external rotation). The coronal angle of the tibia was 0.46° varus on plain radiograph, 0.72° varus on CT, 0.37° valgus in navigation (p=0.005). Posterior slope was 2.53° on plain radiograph and 0.67° in navigation (p< 0.001). There was no correlation between postoperative rotational position of the tibia relative to the femur and the difference in the tibial coronal angle between navigation data and CT.

The proposed anteroposterior axis of the tibia centered between 0 to 5 degrees internally rotated position relative to the femur but showed wide range of deviation. The rotation angle of the tibial cutting in navigated TKR did not influence on the postoperative measurement discrepancy between navigation and CT.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 115 - 115
1 Mar 2010
Park D Lee M Lee D Lee S Kim J Park J
Full Access

Hyaluronic acid (Hyalunan, HA), β-1,4-linked D-glucuronic acid and β-1,3 N-acetyl-D-glucosamine polysaccharide, is a nonsulfated glycosaminoglycan(GAG) conserved in the extracellular matrix (ECM). Due to its biocompatibility, biodegradable properties, HA is widely applied for tissue engineering. However, HA also has defects for tissue engineering such as mechanical properties, difficulty of handling. Thus, it is various modified by chemical reaction to produce HA derivative. HA plays an important role in tissue morphogenesis, proliferation and cell differentiation. Ascorbic acid (AA) has an effect on collagen synthesis and bone mineralization. Ascorbate levels also have a significant effect on osteoblast proliferation and alkaline phosphatase (ALP) expression. However AA is weak to heat and light, thus it is easily degradable. Consequently, we conjugated HA with AA in order to make it more stable and effective. In this study, we prepared HA-AA conjugate and evaluated activity of products in pre-osteoblast.

To produce more effective conjugation, we synthesised HA derivative, HA-N-hydroxysuccinimide, an activated ester of the glucuronic acid moiety. This HA-active ester intermediate is a precursor for drug-polymer conjugates. The degree of substitution was calculated by NMR analysis. The modified HA was dialysed and lyophilised. The yield of conjugation is calculated by Gel Permeation Chromatography (GPC). After the process, HA was conjugated with AA once again as previously mentioned. In this study, the resultant HA-AA conjugate was tested on MC3T3-E1, murine pre-osteoblast cells. We examined cellular viability (cytotoxicity), proliferation and gene expression. The expression of Type 1 collagen was examined by RT-PCR and western blot. Osteocalcin (OCN), osteopontin (OPN) and bone sialoprotein (BSP), bone proliferation and differentiation marker were detected by RT-PCR. Alkaline phosphatase assay was also performed. For confirmation on bone mineralization, alizarin red staining and von Kossa staining was performed.

In conclusion, the in vitro data demonstrate that HA-AA conjugate has an important role in bone formation, as it can increase proliferation and osteogenic differentiation of MC3T3-E1 cells. These observations further support the use of in vivo system for tissue engineering applications.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 161 - 162
1 Mar 2010
Lee S Seong S Kim D Lee M
Full Access

Constrained condylar knee (CCK) prosthesis offers an implant option for complex revision total knee arthroplasties in which stable varus-valgus constraint as well as rotational control is needed for severe bone defect and ligament insufficiency. The aim of this study was to evaluate the clinical and radiological outcome of CCK prosthesis in revision TKA.

Fify-one revision TKAs performed using CCK prosthesis between Jan. 1998 and Feb. 2006 were performed. The mean follow-up period was 5 years and 3 months (2 to 9 years) and the interval between initial and revision TKA was 8 years (4 months to 21 years). The mean age was 67 years. Range of motion (ROM), knee society (KS) score, hospital for special surgery (HSS) score, complication rate and failure rate was evaluated. The tibiofemoral angle and radiolucent line was also evaluated on plain radiograph.

The mean ROM improved from 81.9° to 102°. The mean KS score improved from 49.3° to 79.7°, and KS function score from 50.3 to 71.0 (P< .001). The mean HSS score improved from 50.7 to 78.7 (P< .001). Tibiofemoral angle improved from valgus 3.1° to valgus 5.6° (P< .001). Radiolucent line more than 2mm was observed around 4 femoral and 4 tibial components. Complications including 1 skin necrosis, 1 tibial tubercle nonunion, 2 infections, 3 periprosthetic fractures and 5 arthrofibrosis were observed. Overall rating was excellent or good in 88% at the last follow up.

Revision TKA using CCK prosthesis showed comparable results with other reports in average 5 years follow-up.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 164 - 165
1 Mar 2010
Kim Y Park W Kim K Kim K Lee S
Full Access

Even though spinal fusion has been used as one of the common surgical techniques for degenerative lumbar pathologies, high stiffness in the fusion segment could generate clinical complications in the adjacent spinal segment. To avoid these limitations of fusion, the artificial discs have recently used to preserve the motion of the treated segment in lumbar spine surgery. However, there have been lacks of biomechanical information of the artificial discs to explain current clinical controversies such as long-term results of implant wear and excessive facet contact forces. In this study, we investigated the biomechanical performance for three artificial discs in the lumbar spinal segments by finite element analysis.

A three-dimensional finite element model of five spinal motion segments, from L1 to S, in intact lumbar spine was reconstructed from CT images. Finite element models of three artificial discs, semi-constrained and metal on polyethylene core type (ProDisc® II, Spine Solutions Inc., USA; Type I), semi-constrained and metal on metal type (MaverickTM, Medtronic Sofamor Danek Inc., USA; Type II), and un-constrained and metal on polyethylene core type (SB ChariteTM III, Dupuy Spine Inc., Switzerland; Type III) were developed. Each artificial disc was inserted at L4–L5 segment, respectively. Upper and lower plates of artificial discs were attached on the L4 and L5 vertebrae. Some parts of ligaments and intervertebral disc in L4–L5 motion segment were removed to insert artificial discs. Nonlinear contact conditions were applied on facet joints in lumbar spine model and artificial discs. Bottom of sacrum was fixed on the ground and 5Nm of flexion and extension moments were applied on the superior plate of L1 with 400N of compressive load along follower load direction.

In extension, all three artificial disc models showed higher rotation ratio at the surgical levels, but lower rotations at the adjacent levels than those in the intact model. There was no big difference of the intersegmental rotations among the artificial disc models. For the comparison of the peak von-Mises stresses on the polyethylene core in flexion, 52.3 MPa in type I implant was higher than 20.1 MPa in Type III implant while the peak von-Mises stresses were similar, 25.3 MPa and 26.5 MPa in Type I and III, respectively in extension. The facet contact forces at the surgical level for the artificial disc models showed 140 to 160 N in extension whereas the facet contact force in the intact model was 60 N.

From the results of this study, we could investigate the biomechanical characteristics of three different artificial disc models. The relative rotation at the surgical level would be increases at the early outcome after total disk replacement. The semi-constrained type artificial disc could generate higher wear risk of the implant than unconstrained type. Also all types of artificial disc model have higher risk of facet joint arthrosis, and especially in the semi-constrained and metal on metal type. The results of the present study suggested that more careful care must be taken to choose surgical technique of total disc replacement surgery.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 133 - 134
1 Mar 2010
Kim Y Kim K Park W Lim Y Kim K Lee S
Full Access

Spinal fusion has been used as the gold standard to treat some spinal disorders such as degenerative disc or disc herniation of the cervical spine. However, some clinical complications have been reported caused by high stiffness of spinal fusion. Recently, total disc arthroplasty using motion preservation devices such as artificial discs (ADs) have been proposed as an alternative treatment technique. In current study, we analysed biomechanical influences including inter-segmental motion, facet joint forces, and ligament stresses of two different clinical available ADs and compared with those of intact cervical spine in various loading conditions using finite element analysis.

A three dimensional finite element model was developed for C2-C7 spinal motion segment based on CT images and previous anatomical literatures. The finite element models for two different types of ADs, semi-constraint (Prodisc-C®, Synthes, U.S.A) and un-constraint (Mobi-C®, LDR Spine, U.S.A), were developed. Each AD was inserted at C6–C7 segments. Superior and inferior plates of ADs were fixed on inferior plane of C6 and superior plane of C7 vertebrae, respectively. Based on the conventional surgical techniques, anterior longitudinal ligaments and some parts of intervertebral disc in C6–C7 motion segment were removed to insert ADs. Inferior plane of C7 vertebra was constrained in all directions and 1Nm of flexion, extension, lateral bending and torsion were applied on superior plane of C2 vertebra with 50N of compressive load along follower load direction.

Rotation angle in flexion of C5–C6 segment in cases of semi-constraint and un-constraint AD was 3.3° and 3.7°, respectively. Both values were greater than that in case of the intact cervical spine by 18% and 32%, respectively. Rotation angle in extension, lateral bending and torsion were greater than intact model by 45%, 26% and 43% for the case of semi-constraint AD and 55%, 35%, 100% for the case of un-constraint one, respectively. In extension, facet joint forces were about two times higher than intact model in cases of semi-constraint and un-constraint AD. Also in flexion, on average, ligament stresses in cases of semi-constraint and un-constraint AD were higher than intact model by 66% and 116%, respectively.

The results of this study showed that ADs were useful to generate inter-segmental motion at surgical level. And the un-constraint type of AD had higher mobility than semi-constraint one. However, high mobility of ADs would lead not only higher facet joint forces but also ligament stresses than intact cervical spine. Therefore, more careful care must be taken to choose surgical method of total disc arthroplasty.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 165 - 165
1 Mar 2010
Kim D Lee K Lee S Park C Choi J
Full Access

Ultra-high molecular weight polyethylene (UHMWPE) has been used for the bearing liner or inlay components in total joint replacements such as total hip, knee, and artificial disk since 1960’s. UHMWPE components generate wear debris during articulation, which play a key role in osteolysis, subsequent aseptic loosening, and eventually revision surgery. Efforts to solve the wear problem in UHMWPE and to quantify the amount of wear have driven many studies. But in vivo radiographic penetration depth measurement is the result of both wear and viscoelastic creep. Previous study reported that over 70% of the dimensional changes in UHMWPE acetabular cups were due to creep. Creep deformation was quantified under the static and dynamic compressive pressures (2, 4, 8Mpa) that are clinically relevant for the hip joint loads in normal motions. However, according to the finite element stress analyses in UHMWPE components under the active motions in hip, knee, and artificial disk replacements, very high level of contact pressures locally ranged from under 10MPa up to over 60Mpa. In this study, we quantified the creep of UHMWPE under the several high levels of dynamic compressive pressures and compared the results from the previous results.

For creep tests, UHMWPE rectangular blocks (10mm long, 10mm wide, 8mm thick) were manufactured from molded unirradiated Chirulen® 1020 sheet (MediTECH, Deutchland). MTS 858 hydraulic test machine was used for conducting the dynamic compressive creep tests under the four different sinusoidal (1Hz) maximum pressures of 10, 20, 40, and 60MPa and minimum pressures of 1, 2, 4, and 6MPa, respectively. All tests were conducted for a total duration of 4×103 minutes at ambient conditions. During the test the displacements of crosshead were stored and the changes in thickness of block specimen devided by the initial thickness were calculated to get the creep strain.

The mean dynamic compressive creep strain increased as the loading time increased and had a linear relationship (R2=0.96) with the logarithmic scale of time for all maximun pressures. Over 90% of total creep strain occurred within the first 103 minutes. The rates of creep strain (slopes of curve fitting in logarithmic scale of time) for each maximum pressure were listed in Table 1 with the rates of creep strain for low maximum pressures from the previous study [3]. The rates of creep strain increased linearly as the maximum pressure increased for both current study (R2=0.96) and previous study (R2=0.99). The slope of linearity for the current study with high levels of contact pressures was a little larger than that for the previous study with low levels of contact pressures. This difference in the slope of linearity between current and previous studies lies in the creep recovery during measurement of specimen thickness by micrometer in the previous study. Neglecting this difference, the results of current study can be extrapolated to anticipate the creep strain of UHMWPE under the dynamic compression for the low levels of contact pressures.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 165 - 165
1 Mar 2010
Moon Y Lee S Noh K
Full Access

Purpose: To evaluate the normal glenoid size of the Koreans in their 7th and 8th decades with the Computed tomographic (CT) studies.

Materials and Methods: The CT images were obtained from normal scapulae of the patients (mean age : 68.8, range 62–76) with the humeral fracture cases. A Display workstation version 2.0.73.315 was used to measure the scans to determine the maximal superoinferior(SI) and anteroposterior(AP) diameter of the osseous glenoid vault.

Results: The average diameter of curvature of the glenoid were 31.2±2.3mm(range, 27 to 34mm) in the superior-inferior directions and 26.1±2.4mm(range, 22 to 31mm) in anterior-posterior.

Conclusion: This study showed the normal glenoid size of the Korean and it is smaller than the size which the international literature reported. It would be important factor for the treatment of fracture or arthroplasty implant designs.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 119 - 120
1 Mar 2010
Kim T Seong S Lee S Kim D Lee M
Full Access

The aim of this study was to evaluate passive kinematics of a mobile-bearing, ultracongruent (UC) total knee design compared with a mobile-bearing, posterior stabilised (PS) design intraoperatively using navigation system.

Thirty-four knees of 24 patients which had undergone total knee arthroplasty with UC prosthesis (E-motion®, Aesculap, Tuttlingen, Germany) for primary osteoarthritis and fifteen knees of 14 patients with PS prosthesis (E-motion®) were included in this study. Thirty-one female and seven male patients were included and the mean age was 70.4 years. Patients were followed up for 7.26 months (6 to 12 months). Intraoperative kinematics including valgus/varus rotation, internal/external rotation, and anterior/posterior translation was assessed from 10° to 120° of passive flexion before and after total knee replacement using a surgical navigation system (Orthopilot®, Aesculap). The range of motion (ROM) was measured preoperatively and at the final follow up.

The tibiofemoral alignment in 10° flexion changed from varus 5.85° to valgus 0.38° in UC group and changed from varus 7.45° to valgus 1.08° in PS group (p> 0.05), the magnitude of varus rotation during flexion was 0.01° in UC group and 4.08° in PS group (p< 0.05). PS knee showed the tendency to slight varus alignment during flexion but UC knee showed the tendency toward valgus alignment fter midflexion. The mean internal rotation during flexion was 10.3° in UC group and 13.2° in PS group (p> 0.05). The translation of the femur was 4.99mm posteriorly in UC group and 3.24mm posteriorly in PS group at 120° flexion (p> 0.05). The maximum flexion angle at the final follow up was 123° in UC group and 118° in PS group (p> 0.05). Total knee arthroplasty with high flexion PS prosthesis showed good ROM and satisfactory early clinical results.

UC total knee design showed less varus rotation during flexion, more valgus pattern in higher flexion angle than PS design, similar internal rotation angle and pattern, and similar posterior translation at 120° flexion with PS design.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 159 - 159
1 Mar 2010
Jung K Lee S Song M Hwang S Kim DS
Full Access

Spontaneous osteonecrosis of the knee (SPONK) usually involves a single condyle or plateau. The medial femoral condyle is most often involved and spontaneous osteonecrosis of medial tibial plateau is a rare condition, representing only 2 % of all necrosis reported in the knee. Therefore, SPONK with both involvement of medial femoral condyle(MFC) and medial tibial plateau(MTP) might be extremely rare. SPONK in each MFC or MTP respectively might be extended into corresponding side of the knee at their advanced final stage, howevere, in that situations, significant degenerative change would accompany and it might be difficult to differentiate final staged SPONK form severe osteoarthritis. To the best of our knowledge, SPONK affecting both medial femoral condyle and medial tibial plateau without significant secondary osteoarthritis changes is not reported, even though it was difficult to know which occurred first. We experienced 3 patients with histologically proven osteonecrosis of the medial tibial condyle and medial tibial plateau, and report their radiologic features. All 3 patients showed similar ridiograhic patterns. Medial portion of medial tibial plateau and lateral portion of medial femoral condyle showed longitudinal fracture like-subchondral collapse. Standing anteroposterior radiograph at 30 degree knee flexion showed well fitted features such as “locked” medial condyle. Varus angulation was present. Significant degenerative changes was not shown except for subchondral sclerosis. T1-weighted coronal and Fat suppressed T2-weighted MR images showed subchondral collapse with ill-defined diffuse bone marrow edema changes on both tibial and femoral condyles. At surgical findings, longitudinal track-like groove was shown in both medial femoral condyle and medial tibial plateau. Articular cartilage was denuded and showed glistening surface with bone defect of lateral side of medial femoral condyle and medial side of tibial articular surface. Histological analysis shows necrotic bone, surrounded by an area of fibrovascular granulation tissue on both femoral and tibial sides. Total knee arthoplasty was performed in all 3 patients. As a result of very low prevalence of both involvement of MFC and MTP and limited number of our cases, we could not conclude that radiologic features in our cases are typical radiologic pattern of both involvement. However, based on our cases, we believe that this characteristic radiologic features may considered as one of the possible various radiologic findings of simultaneous involvement in MFC and MTP and allow diagnosis for SPONK with both involvement in MFC and MTP to be facilitated.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 162 - 162
1 Mar 2010
Jung K Lee S Song M Hwang S
Full Access

Arthrodesis is used most commonly as a salvage procedure for failed total knee arthroplasty (TKA). For successful arthrodesis, a stable fusion technique and acceptable limb mechanical alignment are needed. Although the use of intramedullary alignment rods might be helpful in terms of achieving an acceptable limb mechanical axis, fat embolism and intramedullary dissemination of an infection or reactivation of latent infection might occur in failed TKA cases. However, computer-assisted surgery allows precise cuts to be made without breaching medullary cavities. Here, the authors describe a case of knee arthrodesis performed by computer navigation and the Ilizarov method in a patient with a past history of infection. A 45-year-old man visited our hospital with failed total knee arthroplasy. Fortunately, even though infection was treated by debridement with component retention, mild heating was present over the knee, but ESR(erythrocyte sedimentation rate) and CRP(C-reactive protein) were within normal ranges. X-ray showed subsidence of the femoral component and a radiolucent line around the femoral component. Arthrodesis was planned for this patient due to disabling pain, a long-lasting severe functional deficit, failure of the primary TKA for ankylosed knee, and the patient’s poor economic status and his strong desire for arthrodesis. The computer navigation surgery system and the Ilizarov method were used for two reasons. The first reason was that the patient had a past history of infection. At pre-operative evaluation, even though ESR and CRP levels were within normal range, we could not completely rule out the possibility of latent infection due to suspicious findings such as long lasting disabling knee pain, mild heating over the knee, severe osteolytic radiographic changes around the femoral component. In that situation, inserting an IM rod to achieve acceptable mechanical alignment might have reactivated and disseminated a possible latent infection to the femoral or tibial medullary canals. The second reason was that we wanted to reduce the possibility of fat embolism by using computer navigation without instrumentation within the medullary canal. A CT-free, wireless computer navigation system was applied, with trackers fixed to the femur and tibia and no requirement for the use of an IM rod with component retention. Navigated femoral and tibial bone resections were then performed using Stryker software. The femoral resection was conducted at 0° of flexion to the sagittal axis, and the tibial resection at 7 ° of flexion to the sagittal axis. Arthrodesis was held in proper axial and rotational alignment with bone surfaces compressed together. Finally, knee arthrodesis was completed using the Ilizarov method. Based on our experience of the described case, we believe that arthrodesis for failed TKR, especially failure secondary to intraarticular infection, can be considered as another indication for computer navigation.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 163 - 163
1 Mar 2010
Kim HJ Kim TS Kim Y Shu DH Lee S
Full Access

There was used cement in first generation total ankle arthroplasty, but first generation of ankle arthroplasty was abandoned because of aseptic loosening of component. For the treatment of aseptic loosening of ankle arthroplasty, there had been many methods. One of methods of revisional ankle arthroplasty is the ankle arthodesis. The authors report a case of revisional ankle arthroplasty using allograft with hybrid external fixation.

45 year old male had surgery of cemented total ankle arthroplasty on his right ankle 20 years ago. He went to our clinics because of motionless and pain of his right ankle. He got the mild pain on his right ankle after 5 years surgery. His pain was managed by oral NSAIDS for 15 years. The pain was aggravated recently. There were osteophytes on posterior aspect of ankle joint and radiolucency around the implant, subtalar arthrosis at the radiograph. There was also sclerosis around the ankle joint.

The authors decided revisional surgery. At the operative findings, we can see the loosening of talar and tibial component and large posterior osteophyte bridging between remained talus and tibial bone. There were no infection signs. After remove the implant, there was big space remained. For the regaining the limb length, we used femoral head allograft. The graft was fixed with 6.5 mm cannulated screws and addition fixed with ilizarov external fixation. Also additional auto bone graft from the osteophytes was applied. Compression over the ilizarov external fixation was done at the end of the operation. Weight bearing was allowed immediate after surgery. Ilizarov ring was removed 6 weeks after surgery. At the 3 months after surgery, bony union was obtained on radiographs.

AOFAS score was improved from 30 to 70 6 mo after surgery. There was no pain on his right ankle. Patient satisfied with arthrodesis with allograft at final follow-up.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 131 - 131
1 Mar 2010
Kim D Seong S Lee S Lee M
Full Access

Clinical experience has shown the needs for high flexion. The aim of this study was to evaluate the clinical and radiological results of a fixed bearing high flexion posterior stabilized (PS) total knee arthroplasty (TKA).

Between July 2001 and December 2005, 422 TKAs in 288 patients were performed with high flexion PS prosthesis and 378 knees of 258 patients had been followed up for 2 to 6.5 years (mean: 3 years 11 months). We evaluated range of motion (ROM), Knee rating system of the Hospital for Special Surgery (HSS) and Knee Society (KS) score, and radiological results.

The mean flexion improved from 110.1 degrees to 126.7 degrees at the latest follow-up. 333 knees (88 %) showed more than 120 degrees of flexion, 105 knees (28 %) more than 140 degrees of flexion. The mean KS clinical score improved from 39 to 93 points (p< 0.01) and KS function score, from 40 to 85.4 points (p< 0.01). The mean HSS score improved from 41.2 to 86.3 points (p< 0.01). In 28 knees, radiolucent line of 1–2 mm in width was observed at zone 1 without symptoms. Aseptic loosening in 4 knees, Mid-flexion instability in 2 knees, superficial infection in 3 knees and deep infection in 3 knees were observed.

Total knee arthroplasty with high flexion PS prosthesis showed good ROM and satisfactory early clinical results. Complication rate was similar to those of other series. Close observation and serial radiological evaluation are needed for long term results.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 95 - 96
1 Mar 2010
Chang J Vegad T Yoo J Lee S
Full Access

Total Hip Arthroplasty (THA) has been more frequently performed for relatively young patients with osteonecrosis of the femoral head in Korea. Moreover, squatting and sitting with crossed legs are more common in Asian cultures than in Western cultures. Wear debris generated by conventional metal-on-PE articulations has been giving rise to extensive osteolysis. Due to these characteristics, higher incidence of pelvic osteolysis was observed after THA in Korea. As a result, interest in alternative bearings such as ceramic-on-ceramic bearing has been increased. Furthermore, the patients who require revision THA are still young in Korea. With this point of view, an application of ceramic-on-ceramic bearing throughout revision THA seems to be reasonable. The clinical and radiographical outcomes after revision THA with use of third generation ceramic-on-ceramic bearing in Korean patients were evaluated.

Materials and Methods: We have analyzed 42 hips (37 patients; 17 men and 20 women), in whom revision THAs were performed using cementless cups with ceramic-on-ceramic bearing (Biolox Forte; CeramTec, Plochingen, Germany). They underwent THA at a single institution between February 2000 and December 2004, and were consecutively enrolled in this study. Their mean age was 48.8 years (32 – 59 years), and their mean weight was 61.5 ± 5.8 kg (50 – 72 kg) and BMI was 23.8. The mean interval from primary to revision THA was 9.5 ± 3.2 years (3.3 – 16.1 years). The preoperative diagnoses for primary THA were osteonecrosis of the femoral head in 31 hips, neglected femoral neck fracture in 3, rheumatoid arthritis in 2, degenerative osteoarthritis in 2, pyogenic arthritis in 2, tuberculosis arthritis in 1, and fused hip in 1. Dissociation of PE liner was observed in 21 hips (50%). For acetabular cup revision, Trilogy ceramic acetabular cups (Zimmer, Warsaw, IN) were used in 22 hips, EP-FIT plus cups (Plus Orthopedics, Rotkreuz, Switzerland) in 14 hips, and Duraloc Option Ceramic cups (DePuy, Warsaw, IN) in 6 hips. Stems were revised in all hips. The follow-up protocol included radiographic and clinical evaluations, and the mean duration of follow-up monitoring after revision THA was 5.4 ± 1.7 years (3.2 – 8.0 years). At final follow-up examination, clinical outcomes including Harris Hip Score and complications were assessed. All changes in inclination were documented radiographically. The presence of radiolucent lines, vertical or horizontal migration of acetabular cup (> 2 mm), and osteolysis were also evaluated.

Results: At final follow-up evaluation after revision, the average Harris Hip Score was 91.3. There were no revised hips during follow-up period. In 6 hips (14.3%), minor complications were observed: 3 heterotopic ossifications, 2 dislocations, 1 infection. No revision was necessary for the treatment of these complications. There were no hips with radiolucent lines, vertical or horizontal acetabular cup migration or osteolysis during the follow-up period. In 21 hips with bone graft, incorporation of bone graft was observed radiographically at final follow-up examination.

Conclusions: Our data showed that clinical and radiographical outcomes after revision THA using third generation ceramic-on-ceramic bearing were favorable. Revision THA with the use of ceramic-on-ceramic bearing surfaces can be preferentially considered especially in young patients. Further studies with long-term follow-up data are warranted.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 165 - 165
1 Mar 2010
Moon Y Lee S Noh K
Full Access

The treatment of rotator cuff arthropathy due to irreparable massive rotator cuff tear is still challenging. We performed reverse total shoulder arthroplasties for 2 cases of cuff tear arthropathy. The short term follow-up after the surgery reveal excellent results by ASES and UCLA score. However, these results still require long term follow-up and the study about implant design for the shoulder anatomy of the Koreans.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 111 - 112
1 Mar 2010
Lee S Ahn Y Chung S
Full Access

Extensive bone deficiencies in proximal femur remains a significant challenge in hip surgery. In such a situation, one alternative is to use a proximal femoral allograft-prosthesis composite (APC) to restore the mechanical integrity and bone stock. The current study was performed to analyze the results of APC in the treatment of femoral bone deficiency.

From January 1996 to June 2006, 12 patients who received 15 APC (3 of them received repeated APC), were followed for a mean of 4.2 years (range 2.0 to 9.8 years) by one surgeon. 5 were males and 7 were females and the mean age of the patients was 60.9 years (range 32 to 84 years). 6 patients were diagnosed with septic loosening, 5 were with aseptic loosening, 4 were with re-revision arthroplasty, and 1 was with limb salvage procedure due to malignancy and all were treated with fresh-frozen allograft. The surgical technique was used to cement the femoral component into the allograft but not into the host bone except 1 case.

The average Harris hip score improved from 21.8, preoperatively, to 83.2, the latest follow-up, and the all stems showed good stability except 3 cases of aseptic loosening. These 3 cases went through a repeated operation with another APC after mean 83.7 months (51,92,108 months) and their results showed good stability. 11 APC had a good junctional union. One case was showed junctional nonunion that needed onlay graft at 3.3 years after APC. There were no infections (or septic loosening), dislocations and allogragt fractures (except one great trochanter avulsion fracture, neither clinical symptoms nor went a surgical treatment).

This study demonstrated that the use of APC for extensive proximal femoral bone deficiencies showed a clinically, functionally and radiologically good results. Therefore it is considered as a good options.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1094 - 1096
1 Aug 2009
Kim S Moon H Chun Y Chang W Kim S Lee S

We report the case of a 24-year-old man with a congenital meniscoid articular disc of the triangular fibrocartilage complex with extensor carpi ulnaris tenosynovitis. His young age, the normal articular cartilage, the lack of degenerative changes at the margins of the defect and its bilateral occurrence made this diagnosis likely. A congenital defect of the articular disc of the triangular fibrocartilage complex should not be misinterpreted as a traumatic rupture and is usually asymptomatic.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 232 - 232
1 May 2009
Sethi A Lee S Vaidya R
Full Access

The purpose of this study was to investigate the efficacy and fusion rates of a unilateral pedicle screw construct supplemented with a translaminar screw in transforaminal lumbar interbody fusion (TLIF). The construct was used with an aim of providing suitable spine stiffness with minimal implant load for spinal fusion.

Nineteen consecutive patients who underwent single level TLIF were included in the study. All patients had posterior spinal instrumentation using a unilateral pedicle screw construct with a contralateral translaminar screw. Patients were assessed preoperatively and at two, six, twelve and twenty-four weeks following surgery and at the end of one and two years. At every visit Oswestry disability index score,Visual analogue scale for pain and a pain diagram were recorded. A radiographic exam was also conducted and CT scan was done if there was concern about fusion.

The average follow up was twenty-four months. There were twelve males and seven females with an average age of forty-eight years. All patients went on to clinical and radiographic union. Sixteen of nineteen patients had significant clinical improvement on VAS for pain, Oswestry scores and pain medication. Three patients had recurrence of radicular pain on the side of the TLIF leading to reexploration. In all three patients solid fusion was observed but scar tissue was evident and symptoms resolved following redecompression of the foramen.

The biomechanical competence of a construct is evidenced by successful fusion. With the advent of minimally invasive techniques to achieve spinal fusion the goal is to use minimal instrumentation without compromising on the final stiffness of the spine. The construct of unilateral pedicle screws supplemented with a trans-laminar screw led to fusion in all our cases. It requires lesser soft tissue dissection and the posterior implants are 56% cheaper.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 164 - 164
1 Mar 2009
Green S Lee S Joyce T Unsworth A
Full Access

The first metatarsophalangeal (MTP) joint is the key joint of the foot in terms of function during gait. Various replacement toe joint prostheses are commercially available but unlike other replacement joints such as the hip or knee, few simulator based studies have been conducted to evaluate the performance and reliability of these prostheses. Presented are results obtained using a newly developed and validated multi-station MTP joint test-rig that is able to simulate the natural biomechanics of the toe joint. The developed simulator is a multi-station computer controlled electro-pneumatic metataso-phalangeal joint simulator that applies dynamic loading and motions commensurate with the walking gait cycle. This involves the combination of plantar-dorsi flexion range of 32 degrees, 5 degrees of inversion/eversion and toe-off dynamic loading peaking at up to 820 N. Presented are the validation and in vitro test results of MTP joint simulations carried out on silastic and articulating metal and polymer designs of MTP prostheses. Despite being subjected to a reduced loading regime of 300 N peak force, the silastic prostheses were found to perform poorly in the simulator, ultimately failing due to a combination of fatigue crack growth and joint collapse. This behaviour and failure mode was consistent with that of ex vivo origin silastic MTP prostheses examined and provides confidence in the validity of the simulator.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 623 - 628
1 May 2006
Gong HS Chung MS Lee YH Lee S Lee JO Baek GH

We have performed a form of lunate replacement arthroplasty, which included excision of the lunate and insertion of a vascularised radial bone flap wrapped in pronator quadratus, for stage IIIB or stage IV Kienböck’s disease, in 41 patients who have been followed up for more than three years.

All patients reported an improvement in their symptoms, and 20 of the 41 became free of pain after the operation. Extension and flexion of the wrist were increased by a mean of 9° and 6°, respectively (p < 0.05). The radioscaphoid angle and the carpal height ratio were not significantly changed and only minimal deterioration was observed due to degenerative change. The size, density or location of the inserted bone did not change with time.

A vascularised radial bone flap wrapped in pronator quadratus can be a reliable treatment option for advanced Kienböck’s disease, when the pedicled bone and muscle envelope acts as a stable spacer for the excised lunate.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 520 - 523
1 Apr 2006
Lee DY Ahn Y Lee S

We carried out a study to determine the effect of facet tropism on the development of adolescent and adult herniation of the lumbar disc. We assessed 149 levels in 140 adolescents aged between 13 and 18 years and 119 levels in 111 adults aged between 40 and 49 years with herniation. The facet tropism of each patient was measured at the level of the herniated disc by CT.

There was no significant difference in facet tropism between the herniated and the normal discs in both the adolescent and adult groups, except at the L4-L5 level in the adults. Facet tropism did not influence the development of herniation of the lumbar disc in either adolescents or adults.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1081 - 1084
1 Aug 2005
Han I Chang CB Lee S Lee MC Seong SC Kim TK

We sought to determine the degree of correlation between the condition of the patellar articular cartilage and patellofemoral symptoms and function in osteoarthritic patients undergoing total knee arthroplasty. The depth of the osteoarthritic lesion, as graded by the Outerbridge classification and its size and location were assessed to determine the condition of the patellar cartilage in 80 consecutive osteoarthritic knees undergoing total knee arthroplasty. The association between the condition of the cartilage and patellofemoral symptoms and function was investigated by correlation analysis.

The depth and size of the lesion had a significant but weak correlation with anterior knee pain (r = −0.300 and −0.289; p = 0.007 and 0.009, respectively), whereas location had no significant association (p > 0.05). None had a significant association with patellofemoral functional parameters (chair-rising, stair-climbing, and quadriceps power) (p > 0.05).

Our study indicates that patellofemoral symptoms and function are not completely determined by the condition of the cartilage. Caution should be taken when the symptoms and functional limitations are attributed to a lesion in the patellofemoral joint in making a decision regarding patellar resurfacing in total knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 583 - 587
1 Apr 2005
Szöke G Lee S Simpson AHRW Prescott J

Little is known about the increase in length of tendons in postnatal life or of their response to limb lengthening procedures. A study was carried out in ten young and nine adult rabbits in which the tibia was lengthened by 20% at two rates 0.8 mm/day and 1.6 mm/day.

The tendon of the flexor digitorum longus (FDL) muscle showed a significant increase in length in response to lengthening of the tibia. The young rabbits exhibited a significantly higher increase in length in the FDL tendon compared with the adults. There was no difference in the amount of lengthening of the FDL tendon at the different rates. Of the increase in length which occurred, 77% was in the proximal half of the tendon.

This investigation demonstrated that tendons have the ability to lengthen during limb distraction. This occurred to a greater extent in the young who showed a higher proliferative response, suggesting that there may be less need for formal tendon lengthening in young children.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 409 - 409
1 Apr 2004
Sakai T Sugano N Ohzono K Lee S Nishii T Miki H Haraguchi K Yoshikawa H
Full Access

Introduction: The purpose of this study is to evaluate the clinical and radiogra phic outcome of patients with secondary osteoarthritis of the hip, who underwent custom-made cementless THA.

Methods: Between January 1994 and June 1997, 98 prim ary cementless custom-made THA’s were performed in 76 patients with secondary osteoarthritis and reviewed at mean 6 years follow-up (range: 4 – 7.5 years). Nine patients had a previous femoral osteotomy. There were 69 females and seven males. The mean age at operation was 54 years (40 – 73 years). Custom-made, 125 mm-long, titanium femoral components with blasted surface were fabricated based on the computerized tomography.

Results: The mean Harris Hip Score improved from 43 to 95 points. 97 patients (99%) had more than 80 points for total score, and 2 patients (2%) had thigh pain at the latest follow-up. Radiographically, 86 hips (87%) showed obviously extensive bone ongrowth onto the middle part of the stem while 8 hips (9%) showed stable fibrous fixation. Four hips (4%) were unstable: more than 2 mm subsidence in 2 hips and more than 2 degrees varus migration in 2 hips. Of these 4 hips, 2 had intraoperative cracks of the poximal femur and 2 had varus positioning of the stem.

Discussion and conclusion: Cementless THA has been advocated to enhance fit and fill of variable hip geometry. However, some clinical studies failed to show that custom implants significantly improve clinical success or implant longevity because their surface finish was not optimal. Custom-made titanium femoral components with blasted surface showed good clinical results. The reasons for radiolographical failures were because of intraoperative technical errors and these might be derived from 125 mm-long stem with maximum canal fill. A shorter stem may be an option because it may improve the feasibility of stem insertion and the distal fill.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 335 - 335
1 Mar 2004
Kim S Kim S Oh C Lee S Park I Ihn J
Full Access

Aims: To evaluate the early midterm outcomes of primary total hip arthroplasty (THA) using Hydroxyapatite (HA)-coated on smooth surface acetabular component with 28 mm metal head on polyethylene liner articulation. Methods: Seventy primary THA in 63 patients with HA-coated acetabular component were performed consecutively between June 1993 and August 1996. Fifty-four cases were eligible for follow-up of average 71 months (48–104) and the mean age of index operation was 49 years (23–71). The clinical results were analyzed by modiþed Harris hip score, and the radiologic evaluation in terms of stability, polyethylene wear rate (Dorr method), osteolysis around acetabular component was done. Results: Mean Harris hip score improved from 50.9 to 82.2 at the last follow-up. Excellent or good results were found in 38 cases (70%). Eight cases (15%) were unstable radiologically. Pelvic osteolysis was found at 18 cases (33%). The mean polyethylene wear rate was 0.146 mm/year (0.01–0.45). Wear rate of hip dyaplasia was greater than osteonecrosis signiþcantly (p< 0.05). Seven cases (13%) were revised (5 mechanical failures, 2 deep infections). Any bone ongrowth was not found during revision surgery for loose components. Complications included 5 heterotrophic ossiþcations, 2 deep infections, and 1 nonrecurrent dislocation. Conclusion: Primary THA using HA-coated on smooth surface acetabular component showed unsatisfactory clinical results, accelerated polyethylene wear rate accompanying high incidence of osteolysis, and high loosening rate due to lack of bony ongrowth at early midterm.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 150 - 150
1 Feb 2004
Shon W Lee S Hur C
Full Access

Introduction: The results of transtrochanteric rotational osteotomies for osteonecrosis of the femoral head were reviewed.

Materials and Methods: The results of 26 transtrochanteric osteotomy in 24 patients with Ficat stage II or stage III osteonecrosis of the femoral head performed between April 1994 and June 2001 were evaluated. Osteotomy was primarily conducted on patients younger than 50 years of age when the necrotic lesion was at least 30% of the whole femoral head and was located at the superior aspect. Twenty-three hips in 22 patients were available for clinical and radiological follow-up at 59 months (range, 24–109 months). The average age of the patients at the time of the index procedure was 35 years (range, 23–51 years). The results were considered successful if there was no radiologic failure (progression to necrosis, further collapse) or clinical failure (the need for total hip arthroplasty).

Results: Eighteen (78%) hips had a successful result. Two hips showed progressive varus deformity and were treated by valgus osteotomy. One hip survived and one hip underwent a Girdlestone operation followed by total hip arthroplasty to treat an associated deep infection. Four other hips were also subsequently treated with total hip arthropalsty because of head collapse with severe varus deformity or neck fracture in three hips and infection after osteotomy in one hip.

Discussion: Our results suggest that transtrochanteric osteotomy is a dependable procedure in the treatment of a large lesion even in the later stages of osteonecrosis of the femoral head, which is especially true for patients under the age of 50 years.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 145 - 145
1 Feb 2004
Sakai T Ohzono K Lee S Sugano N Nishii T Miki H Takao M Koyama T Morimoto D Yoshikawa H
Full Access

Introduction: In order to investigate the relationship between the degeneration of the acetabular cartilage and the radiological staging of osteonecrosis of the femoral head, the following study was performed.

Materials and Methods: Acetabular cartilage with sub-chondral bone was taken from the superior dome from 34 hips from 30 patients undergoing total hip arthroplasty due to osteonecrosis of the femoral head. The specimens were stained with hematoxylineosin and safranin-O, and were evaluated as to the thinning of cartilage, fibrillation, clefts, and proliferation of chondrocytes. There were 18 females and 12 males with an average age of 49 years. We used the radiological staging system proposed by the working group of the Specific Disease Investigation Committee under the auspices of the Japanese Ministry of Health, Labor and Welfare. There were eight hips in stage IIIA disease (collapse of the femoral head less than 3 mm), 19 hips in stage IIIB disease (collapse 3 mm or greater), and seven stage IV disease hips.

Results: All 34 specimens showed histological abnormalities. In eight stage IIIA hips, six hips were mild and two were moderate histological degeneration. In 19 stage IIIB hips, five hips were mild, six were moderate, and eight had severe arthrosis. Seven stage IV hips had severe arthrosis.

Discussion: Although the radiographs cannot demonstrate early degeneration of cartilage, degenerative changes were present in all stage III hips. Histological degenerative changes in stage IIIB hips were more severe than those in stage IIIA hips. These findings should be kept in mind in treating patients with osteonecrosis of the femoral head.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 298 - 298
1 Nov 2002
Gepstein R Pekarsky I Folman Y Leitner Y David R Nakai O Lee S
Full Access

Study Design: We describe innovative minimally invasive Israeli made Expandable Spinal Fusion System for lumbar spinal fusion, in patients with all caused of mechanical back pain: Degenerative Disc Disease (DDD) at one or two levels from L2–S1, up to Grade l spondylolysthesis. The purpose of the study was to provide a preliminary evaluation of the safety and efficacy of the Expandable Spinal Fusion System in establishing vertebral stability and fusion, and in improving the quality of life of the patients.

The relatively large diameter of currently used cages dictates extensive manipulations, damaging structures that are crucial for spinal stability.

The Expandable Spinal Fusion System, is 5 mm in diameter in closed configuration, applied in a minimally invasive technique, through a 6mm entering opening by an open or percutaneous posterior procedures. Once in position, its dimensions are increased to a precut size in a controlled procedure. Thus, this system maintains the integrity of facet joints, with no or minimal laminectomy, and minimal damage to the surrounding tissues.

Methods: Data were collected in a series of 60 patients with DDD in levels L3–S1. The patients wee operated in the open posterior approach with or without Pedicle Screws and percutaneous posterolateral. Both end-plates faces were treated by special curettes and partially removed. Posterior iliac bone graft was used and 2 tubes device were introduced to the inter-somatic space under direct vision controlled by X-rays C-Arm intensifying magnification.

Data: The implantation approach was posterior in 52 patients, anterior in 2 and percutaneous in 6 patients. Maximal follow up period is 12 months. Patients follow up was completed according to investigational protocol mandate follow up visit at 1.5, 3, 6, 12 months postoperatively. The main at the time of the surgery was 52 years old. 57 underwent surgery at one level as follows: 3 at L3-L4, 32 at L4-L5, and 21 at L5-S1, and 3 underwent surgery at two levels.

Patient questionnaire pain and quality of life was evaluated using the Oswestry questionnaire and VAS measurement. The patient fill those pre-operatively and at each follow up visit.

Results: Although follow up period is short according to preliminary data, the Expandable Spinal Fusion System has proved to be safe, effective, as well as easy to handle for treating all cases of mechanical back pain: DDD. There was no neurological injury, no infection, no death and no worsening of clinical symptoms. There was no breakage or migration of the implant at the last follow-up. Flexion-Extension X-ray show good stability. VAS score for pain dropped from 8 pre op to 2.6 in average 3 months post-op.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 129 - 130
1 Jul 2002
Szõke G Lee S Lakatos J Simpson A
Full Access

It has been shown that the bone, nerve, tendon, and muscle can generate new tissue when a leg is lengthened. In this study we have examined the muscles to see whether the proliferative response occurs uniformly along the fibres or whether it is a disproportionate occurrence, and also to see whether the muscles of animals of different age responded differently.

In five adult (more than 25 weeks) and five young (8 to 9 weeks) New Zealand White rabbits, a mid-diaphyseal tibial osteotomy was created and stabilised with an Orthofix (M-100) external fixator. After seven days, lengthening was carried out at a rate of 1.6 mm/day until a 20% increase in the tibial length had occurred. One hour prior to sacrifice, all of the animals were injected with bromodeoxyridine (BrdUrd, 40mg/kg).

Proliferative response of muscle tissue was assessed by measuring the positive staining index (PSI) of BrdUrd in a two-step indirect immunohistochemistry using the monoclonal antibody Bu20a. We accomplished this staining in transverse sections (between the proximal and middle third, and between the middle and distal third of the muscle belly) and in longitudinal sections along the proximal, middle and distal third of the myotendinous junction (MTJ) of the lengthened flexor digitorum longus muscle belly. The opposite limb was used as a control for each animal.

All of the muscles showed a proliferative response that was significantly higher on the experimental side. There was no difference between the PSI of the proximal transverse sections and the distal transverse sections. The young animals demonstrated significantly increased PSI in all sections compared with the adult animals (immature distal transverse section PSI: 4.91%; mature distal transverse section PSI: 1.67%). The PSI of the longitudinal sections of MTJ showed significantly higher values than in the muscle belly (PSI at the MTJ in adults: 5.23%; PSI at the MTJ in the young: 13.2 %). The PSI result was increased at the distal third of the MTJ in mature and immature rabbits (p0.05).

The muscles show a proliferative response to elongation forming new muscle tissue. The proliferative reaction to lengthening is far greater in the muscles of growing animals compared to adults. The myotendinous junction demonstrates much more intensive proliferative activity than the muscle belly. The distal third of the myotendinous junction shows the highest PSI results. The results of this study help to interpret the results of the animal model for clinical studies and also indicate an advantage in carrying out lengthening on young individuals.


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 2 | Pages 167 - 179
1 May 1951
Gillis L Lee S

A patient with a chronic discharging sinus or an extensive adherent scar is never safe from the risk of malignant change. Examples are still occurring more than thirty years after the end of the first world war. The possibility should be kept in mind by those concerned with the long-term treatment of wounds of this kind. Reasonable prophylactic measures would be: excision of adherent or unstable scars with, if necessary, their replacement by suitable pedicle flaps having a good blood supply; and earlier amputation if a osteomyelitic sinus persists for several years and does not yield to treatment. Supervision of doubtful cases should be frequent and should not be relaxed with the passage of the years. Warty changes or indolent ulceration of scars should be regarded with grave suspicion and investigated by biopsy. Any increase in pain or discharge in association with a sinus should receive prompt attention. Finally, if malignant change supervenes, treatment should be as speedy and as radical as with any other cancer. At least thirteen of our twenty-four patients have died of cancer.