Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 20 - 20
7 Nov 2023
Mackinnon T Hayter E Samuel T Lee G Huntley D Hardman J Anakwe R
Full Access

We have previously reported on the medium-term outcomes following a non-operative protocol of a short period of splinting followed by early movement to treat simple dislocations of the elbow.

We undertook extended follow up of our original patient study group to determine whether the excellent results previously reported were maintained in the very long-term. A secondary question was to determine the rate and need for any late surgical intervention.

We attempted to contact all patients in the original patient study group. Patients were requested to complete the Oxford elbow score (OES), the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and a validated patient satisfaction questionnaire. Patients were requested to attend a face-to-face assessment where they underwent a clinical examination including neurovascular assessment, range-of-motion and an assessment of ligamentous stability.

Seventy-one patients (65%) from the original patient study group agreed to participate in the study.

The mean duration of follow-up was 19.3 years. At final follow-up patients reported excellent functional outcome scores and a preserved functional range of movement in the injured elbows. The mean DASH score was 5.22 points and the mean Oxford Elbow Score was 91.6 points. The mean satisfaction score was 90.9 points.

Our study shows that the excellent outcomes following treatment with a protocol of a short period of splinting and early movement remain excellent and are maintained into the very long term. These findings support our hypothesis that this treatment protocol is appropriate and suitable for most patients with simple dislocations of the elbow. The role for primary ligamentous repair for this patient group should be carefully considered. Work to more clearly define the anticipated benefits of surgery for specific patient groups or injury patterns would help to support informed decision making.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 6 - 6
7 Nov 2023
Jeffrey H Samuel T Hayter E Lee G Little M Hardman J Anakwe R
Full Access

We undertook this study to investigate the outcomes of surgical treatment for acute carpal tunnel syndrome following our protocol for concurrent nerve decompression and skeletal stabilization for bony wrist trauma to be undertaken within 48-hours.

We identified all patients treated at our trauma centre following this protocol between 1 January 2014 and 31 December 2019. All patients were clinically reviewed at least 12 months following surgery and assessed using the Brief Michigan Hand Outcomes Questionnaire (bMHQ), the Boston Carpal Tunnel Questionnaire (BCTQ) and sensory assessment with Semmes-Weinstein monofilament testing.

The study group was made up of 35 patients. Thirty-three patients were treated within 36-hours. Patients treated with our unit protocol for early surgery comprising nerve decompression and bony stabilization within 36-hours, report excellent outcomes at medium term follow up.

We propose that nerve decompression and bony surgical stabilization should be undertaken as soon as practically possible once the diagnosis is made. This is emergent treatment to protect and preserve nerve function. In our experience, the vast majority of patients were treated within 24-hours.


Bone & Joint Open
Vol. 2, Issue 5 | Pages 301 - 304
17 May 2021
Lee G Clough OT Hayter E Morris J Ashdown T Hardman J Anakwe R

The response to the COVID-19 pandemic has raised the profile and level of interest in the use, acceptability, safety, and effectiveness of virtual outpatient consultations and telemedicine. These models of care are not new but a number of challenges have so far hindered widespread take-up and endorsement of these ways of working. With the response to the COVID-19 pandemic, remote and virtual working and consultation have become the default. This paper explores our experience of and learning from virtual and remote consultation and questions how this experience can be retained and developed for the future.

Cite this article: Bone Jt Open 2021;2(5):301–304.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 6 - 6
1 Feb 2021
Madurawe C Vigdorchik J Lee G Jones T Dennis D Austin M Pierrepont J Huddleston J
Full Access

Introduction

Excessive standing posterior pelvic tilt (PT), lumbar spine stiffness, low pelvic Incidence (PI), and severe sagittal spinal deformity (SSD) have been linked to increased dislocation rates. We aimed to compare the prevalence of these 4 parameters in unstable and stable primary Total Hip Arthroplasty (THA) patients.

Methods

In this retrospective cohort study, 40 patients with instability following primary THA for osteoarthritis were referred for functional analysis. All patients received lateral X-rays in standing and flexed seated positions to assess functional pelvic tilt and lumbar lordosis (LL). Computed tomography scans were used to measure pelvic incidence and acetabular cup orientation. Literature thresholds for “at risk” spinopelvic parameters were standing pelvic tilt ≤ −10°, lumbar flexion (LLstand – LLseated) ≤ 20°, PI ≤ 41°, and sagittal spinal deformity (PI – LLstand mismatch) ≥ 10°. The prevalence of each risk factor in the dislocation cohort was calculated and compared to a previously published cohort of 4042 stable THA patients.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 27 - 27
1 Oct 2020
Lee G Wakelin E Randall A Plaskos C
Full Access

Introduction

Neither a surgeon's intraoperative impression or computer navigation parameters have been shown to be predictive of postoperative outcomes following TKA. The purpose of this study is to determine 1) whether a surgeon and a robot can predict the 1-year KOOS pain score (KPS) and 2) determine what factors correlate with poor KOOS scores in well aligned and balanced TKA.

Methods

The data of 131 consecutive patients enrolled in a prospective trial was reviewed. All TKAs were performed using a dynamic ligament tensioning robotic system with a tibial first resection technique and a cruciate sacrificing ultracongruent knee implant. Each TKA was graded based on the final recorded mediolateral ligament balance at 10° and 90°: A) <1mm with an implanted insert thickness equal to planned (n=74); B) <1mm (n=25); C) <2mm (n=26); D) >2mm (n=6) (Table-1). The 1-year KPS for each knee grade were compared and the likelihood of achieving an KPS > 90 was calculated. Finally, the factors associated with lower KPS despite achieving a high grade TKA (A/B) was performed. The Mann-Whitney U test and Chi-squared analysis was performed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 14 - 14
1 Oct 2020
Gu Y Madurawe C Kim W Pierrepont J Shimmin A Lee G
Full Access

Introduction

The prevalence of the various patterns of spinopelvic abnormalities that increase the risk for prosthetic impingement is unknown. While prior surgery or lumbar fusion are recognized as a risk factors for postoperative dislocation, many patients presenting for THA do not have obvious radiographic abnormalities. The purpose of this study is to determine the prevalence of large posterior pelvic tilt (PPT) when standing, stiff lumbar-spine (SLL) and spino-pelvic sagittal imbalance (SSI) in patients undergoing primary THA.

Methods

A consecutive series of 1592 patients (56% female) over 2 years underwent functional analysis of spinopelvic mobility using CT, standing, and flexed seated lateral radiographs as part of pre-operative THA planning. The average age was 65 (20–93). We investigated the prevalence of these 3 validated spinopelvic parameters known to increase the risk for impingent and correlated them to the patient's age and gender using Chi squared analysis. Finally, the risk of flexion and extension impingement was modeled for each patient at a default supine cup orientation (DSCO) of 40°/20° (±5°).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 7 - 7
1 Oct 2020
Goswami K Clarkson S Dennis DA Klatt BA O'Malley M Smith EL Pelt CE Gililland J Peters C Malkani AL Palumbo B Minter J Goyal N Cross M Prieto H Lee G Hansen E Ward D Bini S Higuera C Levine B Nam D Della Valle CJ Parvizi J
Full Access

Introduction

Surgical management of PJI remains challenging with patients failing treatment despite the best efforts. An important question is whether these later failures reflect reinfection or the persistence of infection. Proponents of reinfection believe hosts are vulnerable to developing infection and new organisms emerge. The alternative hypothesis is that later failure is a result of an organism that was present in the joint but was not picked up by initial culture or was not a pathogen initially but became so under antibiotic pressure. This multicenter study explores the above dilemma. Utilizing next-generation sequencing (NGS), we hypothesize that failures after two stage exchange arthroplasty can be caused by an organism that was present at the time of initial surgery but not isolated by culture.

Methods

This prospective study involving 15 institutions collected samples from 635 revision total hip (n=310) and knee (n=325) arthroplasties. Synovial fluid, tissue and swabs were obtained intraoperatively for NGS analysis. Patients were classified per 2018 Consensus definition of PJI. Treatment failure was defined as reoperation for infection that yielded positive cultures, during minimum 1-year follow-up. Concordance of the infecting pathogen cultured at failure with NGS analysis at initial revision was determined.


Bone & Joint Research
Vol. 9, Issue 7 | Pages 440 - 449
1 Jul 2020
Huang Z Li W Lee G Fang X Xing L Yang B Lin J Zhang W

Aims

The aim of this study was to evaluate the performance of metagenomic next-generation sequencing (mNGS) in detecting pathogens from synovial fluid of prosthetic joint infection (PJI) patients.

Methods

A group of 75 patients who underwent revision knee or hip arthroplasties were enrolled prospectively. Ten patients with primary arthroplasties were included as negative controls. Synovial fluid was collected for mNGS analysis. Optimal thresholds were determined to distinguish pathogens from background microbes. Synovial fluid, tissue, and sonicate fluid were obtained for culture.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 85 - 85
1 Feb 2020
Dennis D Pierrepont J Madurawe C Lee G Shimmin A
Full Access

Introduction

It is well accepted that larger heads provide more stability in total hip arthroplasty. This is due to an increase in jump height providing increased resistance to subluxation. However, other implant parameters also contribute to the bearing's stability. Specifically, the liner's rim design and the centre of rotation relative to the liner's face. Both these features contribute to define the Cup Articular Arc Angle (CAAA). The CAAA describes the degree of dysplasia of the acetabular liner, and plays an important role in defining the jump height.

The aim of this study was to determine the difference in jump height between bearing materials with a commonly used acetabular implant system.

Methods

From 3D models of the Trinity acetabular implant system (Corin, UK), the CAAA was measured in CAD software (SolidWorks, Dassault Systems, France) for the ceramic, poly and modular dual mobility (DM) liners, for cup sizes 46mm to 64mm. The most commonly used bearing size was used in the analysis of each cup size. For the ceramic and poly liners, a 36mm bearing was used for cups 50mm and above. For the 46mm and 48mm cups, a 32mm bearing was used. The DM liners were modelled with the largest head size possible. Using a published equation, the jump height was calculated for each of the three bearing materials and each cup size. Cup inclination and anteversion were kept constant.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 40 - 40
1 Oct 2019
Lee G Colen D Levin LS Kovach S
Full Access

Introduction

Infection following TKA can be a catastrophic complication that can cause significant pain, morbidity and jeopardize limb viability. The integrity of the soft tissue envelope is critical to successful treatment and infection control. While local tissue flaps can provide adequate coverage for most soft tissue defects around the knee, there are cases that require salvage using microvascular free tissue transfers. The purpose of this study is to evaluate the 1) rate of limb salvage; 2) infection control; and 3) clinical function following free flap coverage for salvage of the infected TKA.

Materials and Methods

We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and 7 women with a mean age of 61.2 years (range 39–81). The median number of procedures performed prior to soft tissue coverage was 5 (range 2–9) and all patients had failed at least one 2 stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function. The rate of limb salvage and infection control were recorded.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 73 - 73
1 May 2019
Lee G
Full Access

Arthrosis of the hip joint can be a significant source of pain and dysfunction. While hip replacement surgery has emerged as the gold standard for the treatment of end stage coxarthrosis, there are several non-arthroplasty management options that can help patients with mild and moderate hip arthritis. Therefore, the purpose of this paper is to review early prophylactic interventions that may help defer or avoid hip arthroplasty.

Nonoperative management for the symptomatic hip involves minimizing joint inflammation and maximizing joint mobility through intra-articular joint injections and exercise therapy. While weight loss, activity modifications, and low impact exercises is generally recommended for patients with arthritis, the effects of these modalities on joint strength and mobility are highly variable. Intra-articular steroid injections tended to offer reliable short-term pain relief (3–4 weeks) but provided unreliable long-term efficacy. Additionally, injections of hyaluronic acid do not appear to provide improved pain relief compared to other modalities. Finally, platelet rich plasma injections do not perform better than HA injections for patients with moderate hip joint arthrosis.

Primary hip joint arthrosis is rare, and therefore treatment such as peri-acetabular osteotomies, surgical dislocations, and hip arthroscopy and related procedures are aimed to minimise symptoms but potentially aim to alter the natural history of hip diseases. The state of the articular cartilage at the time of surgery is critical to the success or failure of any joint preservation procedures. Lech et al. reported in a series of dysplastic patients undergoing periacetabular osteotomies that one third of hips survived 30 years without progression of arthritis or conversion to THA. Similarly, surgical dislocation of the hip, while effective for treatment of femoroacetabular impingement, carries a high re-operation rate at 7 years follow up. Finally, as the prevalence of hip arthroscopic procedures continues to rise, it is important to recognise that failure to address the underlying structural pathologies can lead to failure and rapid joint destruction.

In summary, several treatment modalities are available for the management of hip pain and dysfunction in patients with a preserved joint space. While joint preservation procedures can help improve pain and function, they rarely alter the natural history of hip disease. The status of the articular cartilage at the time of surgery is the most important predictor of treatment success or failure.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 55 - 55
1 May 2019
Lee G
Full Access

Infection following total knee arthroplasty (TKA) can cause significant morbidity to the patient and be associated with significant costs and burdens to the healthcare system. Wound complications often initiate the cascade that can eventually lead to deep infection and implant failure. Galat et al. reported that wound complications following TKA requiring surgical treatment were associated with 2-year cumulative risks of major reoperation and deep infection of 5.3% and 6.0%, respectively. Consequently, developing a systematic approach to the management of wound problems following TKA can potentially minimise subsequent complications.

Unlike the hip, the vascular supply to the soft tissue envelope to the knee is less robust and more sensitive to the trauma of surgery. Therefore, proper soft tissue handling and wound closure at the time of surgery can minimise potential wound drainage and breakdown postoperatively. Kim et al. showed, using a meta-analysis of the literature, that primary skin closure with staples demonstrated lower wound complications, decreased closure times, and lower resource utilization compared to sutures. However, a running subcuticular closure enables the most robust skin perfusion following TKA. Finally, the use of hydrofiber surgical dressings following surgery was associated with increased patient comfort and satisfaction and reduced the incidence of superficial surgical site infection.

A wound complication following TKA needs to be managed systematically and aggressively. A determination of whether the extent of the involvement is superficial or deep is critical. Antibiotics should not be started without first excluding the possibility of a deep infection. Weiss and Krackow recommended return to the operating room for wound drainage persisting beyond 7 days. While incisional negative pressure wound therapy can occasionally salvage the “at risk” draining wound following TKA, its utilization should be limited only to the time immediately following surgery and should not delay formal surgical debridement, if indicated. Finally, early wound flap coverage and co-management of wound complications with plastic surgery is associated with increased rates of prosthesis retention and limb salvage.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 90 - 90
1 May 2019
Lee G
Full Access

Total hip arthroplasty (THA) is effective, reproducible, and durable in the treatment of hip joint arthritis. While improvements in polyethylene materials have significantly reduced wear rates and osteolysis, aseptic loosening of implants remains one of the leading causes of revision THA. Additionally, fears of dislocation and instability have driven the increase in the utilization of larger diameter femoral heads in primary THA which can lead to increased wear when coupled with a polyethylene articulation. Finally, the increasing number of younger and active patients undergoing THA raises questions with regards to the ability of modern conventional bearings to provide durability and longevity beyond second and third decades following joint implantation.

Ceramic-on-ceramic articulations are ideally suited for today's young and high demand patients undergoing primary THA. It has the lowest in-vitro wear properties of any bearing couple and the wear characteristics are further improved by its wettability and lubrication particularly when larger heads are utilised. Additionally, improvements in material properties and prosthesis design have significantly decreased fracture rates and increased the reliability of these implants. Furthermore, reported outcomes and longevity of modern ceramic-on-ceramic THAs in younger patients have all shown excellent survivorship despite patients achieving and maintaining a very high level of activity and function. In short, it is the bearing couple most in tune with current market demands and utilization trends.

While registry data and meta-analyses of published literature have failed to show the superiority of ceramic-on-ceramic articulations compared to conventional bearings at 10 years, there is evidence that even highly crosslinked polyethylene (HXPE) is not immune to wear. Selvarajah et al. reported steady, in-vivo wear rates of HXPE exceeding 0.1mm/year threshold in young THA patients with 36mm ceramic ball heads. Additionally, small osteolytic lesions have been observed in hips with HXPE bearings at 12–14 years follow up. Finally, analysis of all controlled randomised studies have shown less osteolysis of ceramic-on-ceramic hips compared to polyethylene articulations. The significance of these lesions are unclear but the question remains: Can HXPE as a bearing be able to provide over 30 years of service needed to outlast patients younger than 60 years?

Concerns with cost, squeaking, and fractures do not make ceramic-on-ceramic bearings suitable for all patients undergoing primary THA. However, in young, healthy and active patients, a modern ceramic- on-ceramic articulation is most likely to provide the lowest wear rates, lowest risk of osteolysis, and greatest chance for life-long durability.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 56 - 56
1 Oct 2018
Charette R Sloan M Lee G
Full Access

Introduction

Expanded indications and patient demand have significantly increased the number of TKA performed in young and active patients under age 55. While improved materials have decreased the likelihood of early catastrophic wear, concerns remain with the performance and survivorship of TKA implants in this patient population. Therefore, the purpose this study is to evaluate the clinical outcomes, complications, and implant survivorship of TKAs performed in patients under age 55.

Materials and Methods

We retrospectively reviewed 1194 primary TKA performed for the diagnosis of primary knee osteoarthritis performed at our institution between 2013–2016. There were 291 TKA performed in patients under age 55. Patients were excluded if they had 1) prior history of fracture, 2) renal disease, 3) inflammatory joint disease, and 4) required therapeutic anticoagulation. The primary outcome of interest was rate of revision at 30 days, 1, 2, and 5-year time points. Secondary outcomes included postoperative transfusion rate, calculated blood loss, length of stay(LOS), rate of DVT/PE, readmission and reoperation.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 53 - 53
1 Oct 2018
Charette R Sloan M Lee G
Full Access

Introduction

Total hip arthroplasty (THA) is gaining popularity as a treatment for displaced femoral neck fractures (FNF), especially in physiologically younger patients. While elective THA for primary osteoarthritis (OA) has demonstrated low rates of complications and readmissions, the outcomes of THA for FNF are less predictable. Additionally, these THA procedures are equally included in various alternative payment bundles. Therefore, the aim of this study is to assess postoperative complication rates after THA for primary OA compared with FNF.

Methods

The American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database from 2008 to 2016 was queried. Patients were identified using the Current Procedural Terminology (CPT) code for THA (27130) and divided into groups by diagnosis; OA in one group and FNF in another. Univariate statistics were performed. T-test compared continuous variables between groups, and Chi-square test compared categorical variables. Multivariate and propensity matched logistic regression analyses were performed to control for risk factors of interest. The primary outcomes for this study were death or serious morbidity (surgical site infection (SSI), infection, respiratory complication, cardiac complication, sepsis, or blood loss anemia requiring postoperative transfusion). Additional secondary outcomes included the incidence of specific complications, total operative time (time from incision to closure), length of hospital stay and proportion of patients that were discharged home.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 40 - 40
1 Jun 2018
Lee G
Full Access

Total hip arthroplasty (THA) is reliable and reproducible in relieving pain and improving function in patients with end-stage arthritis of the hip joint. With improvements in surgical technique and advances in implant and instrument design, there has been a shift in focus from the technical aspects of the surgical procedure to improving the overall patient experience. In addition, shifts in medico-economic trends placed a premium on early patient mobilization, early discharge, and maximizing patient satisfaction. Arguably, a single most important advance in arthroplasty over the past 2 decades has been the development of multimodal pain protocols that form the foundation of many of the rapid recovery protocols today.

The principal concept of multimodal analgesia is pain reduction through the utilization of multiple agents that synergistically act at various nodes of the pain pathway, thus, minimizing patient exposure to each individual agent and opioids in order to prevent opioid related adverse events (ORAE). Regional anesthesia has been shown to reduce post-operative pain, morphine consumption, and nausea and vomiting compared to general anesthesia but not length of stay. Additionally, general anesthesia has been shown to be associated with increased rates of post-operative adverse events, The use of peripheral nerve blocks in the form of sciatic, femoral or fascia iliaca blocks have not been shown to significantly reduce post-operative pain compared to controls.

Periarticular infiltration of local anesthetics has been shown in some settings to reduce pain during the immediate post-operative period (<24 h). However, no significant differences were noted in terms of early recovery or complications. The use of liposomal bupivacaine (LB) local infiltration decreased pain and shortened length of stay comparable to patients receiving a fascia iliaca compartment block, and has been shown in relatively few randomised trials to provide improved pain relief at 24 hours only compared to conventional bupivacaine. Continuous intra-articular infusion of bupivacaine after THA did not significantly further reduce post-operative pain compared to placebo.

In summary, the use of regional anesthesia when appropriate along with local anesthetic infiltration in the setting of a robust multimodal pain protocol minimises pain and complications while maximizing patient satisfaction following THA.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 94 - 94
1 Jun 2018
Lee G
Full Access

Infection following total knee arthroplasty (TKA) can cause significant morbidity to the patient and be associated with significant costs and burdens to the health care system. Wound complications often initiate the cascade that can eventually lead to deep infection and implant failure. Galat et al. reported that wound complications following TKA requiring surgical treatment were associated with a 2-year cumulative risk of major reoperation and deep infection of 5.3% and 6.0%, respectively. Consequently, developing a systematic approach to the management of wound problems following TKA can potentially minimise subsequent complications.

Unlike the hip, the vascular supply to the soft tissue envelope to the knee is less robust and more sensitive to the trauma of surgery. Therefore, proper soft tissue handling and wound closure at the time of surgery can minimise potential wound drainage and breakdown post-operatively. Kim et al. showed, using a meta-analysis of the literature, that primary skin closure with staples demonstrated lower wound complications, decreased closure times, and lower resource utilization compared to sutures. However, a running subcuticular closure enables the most robust skin perfusion following TKA. Finally, the use of hydrofiber surgical dressings following surgery was associated with increased patient comfort and satisfaction and reduced the incidence of superficial surgical site infection.

A wound complication following TKA needs to be managed systematically and aggressively. A determination of whether the extent of the involvement is superficial or deep is critical. Antibiotics should not be started without first excluding the possibility of a deep infection. Weiss and Krackow recommended return to the operating room for wound drainage persisting beyond 7 days. While incisional negative pressure wound therapy can occasionally salvage the “at risk” draining wound following TKA, its utilization should be limited only to the time immediately following surgery and should not delay formal surgical debridement, if indicated. Finally, early wound flap coverage and co-management of wound complications with plastics surgery is associated with increased rates of prosthesis retention and limb salvage.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 28 - 28
1 Aug 2017
Lee G
Full Access

Total knee arthroplasty (TKA) is reliable, durable, and reproducible in relieving pain and improving function in patients with arthritis of the knee joint. Cemented fixation is the gold standard with low rates of loosening and excellent survivorship in several large clinical series and joint registries. While cementless knee designs have been available for the past 3 decades, changing patient demographics (i.e. younger patients), improved implant designs and materials, and a shift towards TKA procedures being performed in ambulatory surgery centers has rekindled the debate of the role of cementless knee implants in TKA.

The drive towards achieving biologic implant fixation in TKA is also driven by the successful transition from cemented hip implants to uncemented THA. However, new technologies and new techniques must be adopted as a result of an unmet need, significant improvement, and/or clinical advantage. Thus, the questions remain: 1) Why switch; and 2) Is cementless TKA more reliable, durable, or reproducible compared to cemented TKA?

There are several advantages to using cement during TKA. First, the technique can be universally applied to all cases without exception and without concerns for bone health or structure. Second, cement can mask imprecisions in bone cuts and is a remarkably durable grout. Third, cement allows for antibiotic delivery at the time surrounding surgery which has been shown in some instances to reduce the risk of subsequent infection. Finally, cement fixation has provided successful and durable fixation across various types knee designs, surface finishes, and articulations.

On the other hand, cementless knee implants have had an inconsistent track record throughout history. While some have fared very well, others have exhibited early failures and high revision rates. Behery et al. reported on a series of 70 consecutive cases of cementless TKA matched with 70 cemented TKA cases based on implant design and demographics and found that cementless TKA was associated with a greater risk of aseptic loosening and revision surgery at 5 years follow up. Finally, to date, there has not been a randomised controlled clinical trial demonstrating superiority of cementless fixation compared to cemented fixation in TKA.

Improvements in materials and designs have definitely made cementless TKA designs viable. However, concerns with added cost, reproducibility, and durability remain. Cement fixation has withstood the test of time and is not the main cause of TKA failure. Therefore, until there is significant data showing that cementless TKA is more durable, reliable, and reproducible compared to cemented TKA, the widespread use of these implants cannot be recommended.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 107 - 107
1 Aug 2017
Lee G
Full Access

Improvements in ceramic materials, component design, and surgical technique have made ceramic bearing complications increasingly rare. However, when it happens, a fractured ceramic component can cause significant pain and morbidity following total hip arthroplasty (THA). The hard and sharp particulate debris from fractured ceramic components can cause damage to the existing hip prosthesis and jeopardise subsequent revision THA results due to third body wear.

Patients with ceramic fractures can present with sudden onset of pain and dysfunction. Often, the patient will report a noisy hip articulation. Radiographs can range from subtle densities surrounding the hip implant to complete disintegration and loss of sphericity of the femoral head or acetabular liner.

Ceramic component fractures should be treated expeditiously. Revision options for failed ceramic components depend on existing component fixation, position, and locking mechanism and femoral trunnion integrity. In order to retain the implants, the components must be well-fixed, in good position, and have tapers and locking mechanisms that can accept new modular components. Additionally, an extensile exposure and complete synovectomy are necessary to remove as much of the sharp particulate debris. Finally, a new ceramic ball head with a titanium inner sleeve should be used in revisions for fractured ceramics due to their hardness and scratch resistance.

Early results for revision surgery for fractured ceramic components were inconsistent. Allain et al. reported on a series of 105 revisions performed for ceramic head fractures and found that the survivorship at 5 years was only 63%. The authors reported a high reoperation rate and also worse survivorship when the acetabular component was retained, a metal head was used for revisions, age younger than 50 years, and when a complete synovectomy was not performed at the time of revision. More recently, Sharma and colleagues reported on a series of 8 ceramic fractures revised to a metal-on-polyethylene articulation performed with a complete synovectomy. At 10-year follow-up, the authors reported on failures; increased wear; or lesser function compared to 6 matched patients undergoing revision using similar implants for other diagnoses. Others have also reported catastrophic failures when revising fractured ceramic components using metal ball heads.

In summary, ceramic bearing complications in THA are rare but catastrophic events. A systematic approach to evaluation and management is necessary to ensure a safe return.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 2 - 2
1 Apr 2017
Lee G
Full Access

Total hip arthroplasty (THA) is effective, reproducible, and durable in the treatment of hip joint arthritis. While improvements in polyethylene materials have significantly reduced wear rates and osteolysis, aseptic loosening of implants remains one of the leading causes of revision THA. Additionally, fears of dislocation and instability have driven the increase in the utilization of larger diameter femoral heads in primary THA which can lead to increased wear when coupled with a polyethylene articulation. Finally, the increasing number of younger and active patients undergoing THA raises questions with regards to the ability of modern conventional bearings to provide durability and longevity beyond second and third decades following joint implantation.

Ceramic-on-ceramic articulations are ideally suited for today's young and high demand patients undergoing primary THA. It has the lowest in-vitro wear properties of any bearing couple and the wear characteristics further improved by its wettability and lubrication particularly when larger heads are utilised. Additionally, improvements in material properties and prosthesis design have significantly decreased fracture rates and increased the reliability of these implants. Furthermore, reported outcomes and longevity of modern ceramic-on-ceramic THAs in younger patients have all shown excellent survivorship despite patients achieving and maintaining a very high level of activity and function. In short, it is the bearing couple most in tune with current market demands and utilization trends.

While registry data and meta-analyses of published literature have failed to show the superiority of ceramic-on-ceramic articulations compared to conventional bearings at 10 years, there is evidence that even highly crosslinked polyethylene (HXPE) is not immune to wear. Selvarajah et al. reported steady, in-vivo wear rates of HXPE exceeding 0.1 mm/year threshold in young THA patients with 36 mm ceramic ball heads. Additionally, small osteolytic lesions have been observed in hips with HXPE bearings at 12–14 years follow up. Finally, analysis of all controlled randomised studies have shown less osteolysis of ceramic-on-ceramic hips compared to polyethylene articulations. The significance of these lesions are unclear but the question remains: Can HXPE as a bearing be able to provide over 30 years of service needed to outlast patients younger than 60 years?

Concerns with cost, squeaking, and fractures do not make ceramic-on-ceramic bearings suitable for all patients undergoing primary THA. However, in young, healthy and active patients, a modern ceramic-on-ceramic articulation is most likely to provide the lowest wear rates, lowest risk of osteolysis, and greatest chance for life-long durability.