Results 1 - 9 of 9
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 516 - 516
1 Dec 2013
Sabesan V Callanan M Sharma V Ghareeb G Moravek J Wiater JM
Full Access

Background

There has been increased focus on understanding the risk factors associated with scapular notching in reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the effect of scapular morphology and surgical technique on the occurrence of scapular notching using the notching index as a comprehensive predictive tool.

Methods

Ninety-one patients treated with a primary RSA were followed for a minimum of 24 months. Using a previously published notching index formula ((PSNA × 0.13) + (PGRD)), a notching index value for all patients was calculated. Radiographic assessment of patients were grouped by Nerot grade of scapular notching, group mean differences for prosthetic scapular neck angle (PSNA), peg glenoid rim distance (PGRD), preoperative scapular neck angle (SNA), notching index and clinical outcomes were compared.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 150 - 150
1 Dec 2013
Wiater B Moravek J Pinkas D Koueiter D Maerz T Marcantonio D Wiater JM
Full Access

Introduction:

Reverse total shoulder arthroplasty (RTSA) has become instrumental in relieving pain and returning function to patients with end-stage rotator cuff disease. A distalized and medialized center of rotation in addition to a semi-constrained implant design allows the deltoid to substitute for the non-functioning rotator cuff. The purpose of this study was to examine the relationship between specific deltoid and rotator cuff muscle parameters and functional outcomes following RTSA.

Methods:

Patients undergoing RTSA by a single surgeon were enrolled in a prospective, IRB approved RTSA outcomes registry. Inclusion criteria were diagnosis of cuff tear arthropathy or massive rotator cuff tear, a minimum 2-year follow-up, and a preoperative shoulder MRI. We excluded patients undergoing revision arthroplasty, fracture, and a history of previous open shoulder surgery. For the 28 patients meeting our criteria, the cross-sectional area (CSA) of the anterior, middle, and posterior deltoid were measured on an axial MRI (Figure 1). Fatty infiltration (FI) of the deltoid, supraspinatus (SS), infraspinatus (IS), teres minor, and subscapularis were assessed on sagittal T1-MRI quantitatively via image processing and qualitatively on the 5-point Fuchs scale by a fellowship-trained musculoskeletal radiologist. Outcome measures included active forward elevation (aFE), active external rotation (aER), active internal rotation (aIR), strength in abduction, Constant-Murley score (CMS), Subjective Shoulder Value (SSV), Visual Analogue Scale (VAS) pain, and American Shoulder and Elbow Surgeons (ASES) total and ASES activities of daily living (ADL) scores as assessed by a trained, clinical research nurse. Correlation of deltoid CSA and FI with outcomes measures was analyzed with a Spearman rank correlation coefficient (ρ) with significance at P < .05.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 383 - 383
1 Dec 2013
Kurdziel M Peers S Moravek J Budge M Newton M Baker K Wiater JM
Full Access

Purpose:

Although short term outcomes of reverse total shoulder arthroplasty (rTSA) have been promising, long-term success may be limited due to complications, including scapular notching. Scapular notching has been explained primarily as a mechanical erosion, however, generation of wear debris may lead to further biologic changes contributing to the severity of scapular notching. Highly cross-linked ultra-high molecular weight polyethylene (UHMWPE) has been used routinely in constrained joint applications such as total hip arthroplasty for reduction of wear debris particles. Although rTSA shares similarity in design conformity, conventional UHMWPE remains the gold standard.

Methods:

A commercially available hip simulator was converted to a 12-station rTSA wear simulator. Conventional and highly cross-linked UHMWPE humeral liners were subjected to 5,000,000 cycles of alternating abduction-adduction and flexion-extension loading profiles. Every 250,000 cycles, liners were evaluated with gravimetric wear measurements and test serum was collected for morphological characterization of wear particles.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 166 - 166
1 Dec 2013
Kurdziel M Sabesan V Ackerman J Sharma V Baker K Wiater JM
Full Access

Purpose:

The optimal degree of conformity between the glenoid and humeral components in cemented total shoulder arthroplasty (TSA) has not been established. Glenoid component stability is thought to be at risk due to the “rocking-horse” phenomenom, which, can lead to increased micromotion and loosening in response to humeral head edge loading. The goal of this biomechanical study is to investigate the influence of glenohumeral mismatch on bone-implant interface micromotion in a cemented glenoid implant model.

Methods:

Twenty-Five cemented glenoid components (Affiniti, Tornier, Inc., Bloomington, MN, USA) were implanted in polyurethane foam biomechanics testing blocks. Five glenoid sizes, 40 mm, 44 mm, 48 mm, 52 mm and 55 mm (n = 5 per glenoid size), were cyclically tested according to ASTM Standard F-2028-08. A 44 mm humeral head (Affiniti, Tornier, Inc., Bloomington, MN, USA) was positioned centrally within the glenoid fixed to a materials testing frame (MTS Mini-Bionix II, Eden Prairie, MN, USA). Phase I testing (n = 3 per glenoid size) involved a subluxation test for determination of the humeral head translation distance which would be used for phase II cyclic testing. During cyclic loading, the humeral head was translated ± distance for 50,000 cycles at a frequency of 2 Hz, simulating approximately 5 years of device use. Glenoid compression, distraction, and superior-inferior glenoid translation were measured throughout testing via two differential variable reluctance transducers.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 482 - 482
1 Dec 2013
Wiater B Moravek J Pinkas D Budge M Koueiter D Marcantonio D Wiater JM
Full Access

Introduction:

Studies have demonstrated both clinical and radiological success of reverse shoulder arthroplasty (RTSA), with follow-up approaching 10-years. To date, most RTSA studies involve cemented fixation of the humeral components, and most involving uncemented RTSAs have used implants not necessarily designed for bony ingrowth. Cementless fixation utilizing proximally porous-coated (PPC) femoral implants has shown long term survivorship approaching 99% at greater than 10-years follow-up in total hip arthroplasty. Currently, the number of commercially available PPC RTSA implants is steadily growing, but there has been no published study examining clinical and radiographic outcomes in PPC, press-fit humeral stems. We hypothesized that the clinical and radiographic results of uncemented RTSA utilizing a PPC humeral stem would be similar to cemented RTSA stems when followed for at least 2-years.

Methods:

A prospective, IRB approved RTSA outcomes registry with 261 patients that underwent RTSA by one fellowship-trained orthopaedic surgeon between 2005 and 2008 was reviewed. Inclusion criteria were diagnosis of cuff tear arthropathy or severe rotator cuff deficiency refractory to all other treatments, and minimum 2-year clinical and radiographic follow-up. Exclusion criteria were proximal humeral fractures, glenohumeral instability, rheumatoid arthritis, incomplete follow-up, and revision arthroplasty. Outcome measures included active forward elevation (aFE), active external rotation (aER), active internal rotation (aIR), Constant-Murley score (CS), Subjective Shoulder Value (SSV), visual analogue scale (VAS) pain, and American Shoulder and Elbow Surgeons (ASES) score. Radiographs at 2 weeks, 3 months, 1 year, 2 years and yearly thereafter were evaluated for humeral component position, osteolysis, humeral component radiolucent lines (RLLs), stress shielding, and scapular notching. Statistical analysis was conducted by an independent institutional statistician.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 149 - 149
1 Dec 2013
Wiater B Pinkas D Koueiter D Buhovecky T Wiater JM
Full Access

Introduction:

Reverse total shoulder arthroplasty (RTSA) has become an accepted surgical treatment for patients with severe deficiency of the rotator cuff. Despite the utility of RTSA in managing difficult shoulder problems, humeral rotation does not reliably improve and may even worsen following RTSA. Several approaches to increase active external rotation (aER) postoperatively have been proposed including the use of concomitant latissimus dorsi tendon transfer (LDTT) or the use of an increased lateral-offset glenosphere (LG). We hypothesized that clinical outcome and range of motion after RTSA with a +4 mm or +6 mm LG would be comparable to RTSA with LDTT in patients with a lack of aER preoperatively.

Methods:

An IRB-approved, prospective, single surgeon RTSA registry was reviewed for patients treated with LDTT or LG for preoperative aER deficiency with minimum 1-year follow-up. Patients qualified for aER deficiency if they had a positive ER lag sign or less than or equal to 10 degrees of aER preoperatively. Matched control groups with patients that did not have preoperative lack of aER and were not treated with LDTT or LG were included for comparison. Outcomes measures included Constant-Murley score (CMS), American Shoulder and Elbow Surgeons (ASES) score, Subjective Shoulder Value (SSV), ASES Activities of Daily Living (ADL) score, Visual Analogue pain Scale (VAS), active forward elevation (aFE), active internal rotation (aIR), and aER. An independent, institutional biostatistician performed statistical analyses.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 481 - 481
1 Dec 2013
Kurdziel M Wiater B Moravek J Pinkas D Wiater JM
Full Access

Purpose:

Glenoid loosening persists as a common cause of anatomic total shoulder arthroplasty (TSA) failure. Considering radiographic evidence of loosening as an endpoint, TSA has a reported survivorship of only 51.5% at 10 years. Component loosening may be related to cementation and it is postulated that poor cement penetration and heat-induced necrosis may partially be responsible. There is a growing interest among surgeons to minimize or abandon cement fixation and rely on biologic fixation to the polyethylene for long-term fixation. De Wilde et al. reported promising early clinical and radiographic results using a pegged, all-polyethylene ingrowth glenoid design implanted without cement. The goal of this study was to compare glenoid micromotion in an all-polyethylene, centrally fluted pegged glenoid using 3 cement fixation techniques.

Materials and Methods:

Glenoid components (Anchor Peg Glenoid, Depuy Orthopaedics, Warsaw, IN, USA) (Figure 1) were implanted in polyurethane foam testing blocks with 3 different fixation methods (n = 5 per group). Group I glenoids were implanted with interference fit fixation with no added cement. Group II was implanted with a hybrid fixation, where only the peripheral pegs were cemented. Group III glenoids were fully cemented for implantation. Glenoid loosening was characterized according to ASTM Standard F-2028. The glenoid component and a 44 mm humeral head were mounted to a materials testing frame (858 Mini Bionix II, MTS Crop., Eden Prairie, MN, USA) with a 750N applied joint compressive force (Figure 1). A humeral head subluxation displacement of ± 0.5 mm was experimentally calculated as a value that simulates glenoid rim loading that may occur at higher load activities. For characterization of glenoid loosening, the humeral head was cycled 50,000 times along the superior-inferior glenoid axis, simulating approximately 5 years of device service. Glenoid distraction, compression, and superior-inferior glenoid migration were recorded with two differential variable reluctance transducers fixed to the glenoid prosthesis.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1232 - 1238
1 Sep 2013
Wiater BP Boone CR Koueiter DM Wiater JM

Some surgeons are reluctant to perform a reverse total shoulder arthroplasty (RTSA) on both shoulders because of concerns regarding difficulty with activities of daily living post-operatively as a result of limited rotation of the shoulders. Nevertheless, we hypothesised that outcomes and patient satisfaction following bilateral RTSA would be comparable to those following unilateral RTSA. A single-surgeon RTSA registry was reviewed for patients who underwent bilateral staged RTSA with a minimum follow-up of two years. A unilateral RTSA matched control was selected for each shoulder in those patients undergoing bilateral procedures. The Constant–Murley score (CMS), American Shoulder and Elbow Surgeons (ASES) score, Subjective Shoulder Values (SSV), visual analogue scale (VAS) for pain, range of movement and strength were measured pre- and post-operatively. The mean CMS, ASES, SSV, VAS scores, strength and active forward elevation were significantly improved (all p < 0.01) following each operation in those undergoing bilateral procedures. The mean active external rotation (p = 0.63 and p = 0.19) and internal rotation (p = 0.77 and p = 0.24) were not significantly improved. The improvement in the mean ASES score after the first RTSA was greater than the improvement in its control group (p = 0.0039). The improvement in the mean CMS, ASES scores and active forward elevation was significantly less after the second RTSA than in its control group (p = 0.0244, p = 0.0183, and p = 0.0280, respectively). Pain relief and function significantly improved after each RTSA in those undergoing a bilateral procedure.

Bilateral RTSA is thus a reasonable form of treatment for patients with severe bilateral rotator cuff deficiency, although inferior results may be seen after the second procedure compared with the first.

Cite this article: Bone Joint J 2013;95-B:1232–8.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 34 - 34
1 Mar 2010
Wiater JM Kempton L
Full Access

Purpose: This paper will present the types and rates of complications of an initial consecutive series of 100 reverse total shoulder arthroplasties (TSA).

Method: Since 2004, the initial 100 consecutive reverse TSA were performed by a single US surgeon in 97 patients with an average age of 72 years. A deltopectoral approach was used in all cases. Diagnoses include 49 shoulders with cuff tear arthropathy, 24 with a failed prior shoulder arthroplasty, 23 with an irreparable rotator cuff tear, 2 with a malunion and post-traumatic arthritis, 1 with rheumatoid arthritis, and 1 with osteoarthritis. All patients had painful pseudoparalysis. Average follow-up was 8 months, with 77 patients having a minimum 2-month follow-up. Two patients have expired (unrelated to surgery), and 1 patient has been lost to follow-up.

Results: Of the 100 shoulders, 9 had local perioperative complications (9%) including 2 dislocations requiring 1 open reduction and 1 closed reduction, 2 intraoperative glenoid fractures, 3 resolved mononeuropathies (radial, ulnar, and musculocutaneous), 1 resolving brachial plexopathy, 1 post-op hematoma, and 1 intraoperative broken screw head. Three of the 4 neuropathies occurred in revision arthroplasty shoulders. Six shoulders (6%) had systemic perioperative complications including subacute MI, DVT, PE, and C. difficile colitis. Two patients (2%) have had complications outside the perioperative period including 1 stable acromial fracture at 5 weeks post-op, and 1 patient with a subluxatable shoulder. No infections occurred. Other than the 2 dislocations and the acromial fracture, no radiographic complications, such as dissociation of the components or catastrophic failure of the glenosphere fixation, were observed. Seven shoulders (7%) had Grade 3 scapular notching and none (0%) had Grade 4 notching. The overall complication rate was 18% with rates of 17% vs. 21% in primary vs. revision arthroplasties, respectively (p=0.91). Transient nerve palsies were more frequent in revisions vs. primaries (12.5% vs. 1.3%, p=0.066).

Conclusion: There is an acceptably low rate of complications related to reverse TSA, particularly severe ones requiring reoperation (2%). Overall complication rates are not significantly different between revisions and primaries, but revisions trended towards more transient nerve palsies.