Results 1 - 20 of 28
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 125 - 132
1 May 2024
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP

Aims

Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants – modular fluted tapered (MFT) femoral components – in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components.

Methods

We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims

Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct.

Methods

We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 48 - 48
23 Jun 2023
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP
Full Access

There is a paucity of long-term data on modular fluted tapered (MFT) stems for two-stage reimplantation following periprosthetic joint infection (PJI). The purpose of this study was to evaluate implant survivorship, radiographic results, and clinical outcomes in a large cohort of reimplantation THAs using MFT stems.

We identified 236 reimplantation THAs from a single tertiary care academic institution from 2000 to 2020. Two designs of MFT stems were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years, mean BMI was 32 kg/m2, and 46% were female. Median stem diameter was 19 mm, and median stem length was 195 mm. Mean follow-up was 7 years. A competing risk model accounting for death was utilized.

The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n=25) and PJI (n=16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered portion of the component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only 2 FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence >5 mm occurred in 2% of unrevised cases, and all stems were radiographically stable at most recent follow-up. Mean HHS was 77 at most recent follow-up.

This series demonstrated that MFT stems were durable and reliable even in the setting of two-stage reimplantation for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily caused by dislocation and recurrent PJI.

Level of Evidence: IV


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 74 - 74
23 Jun 2023
Wilson JM Maradit-Kremers H Abdel MP Berry DJ Mabry TM Pagnano MW Perry KI Sierra RJ Taunton MJ Trousdale RT Lewallen DG
Full Access

The last two decades have seen remarkable technological advances in total hip arthroplasty (THA) implant design. Porous ingrowth surfaces and highly crosslinked polyethylene (HXLPE) have been expected to dramatically improve implant survivorship. The purpose of the present study was to evaluate survival of contemporary cementless acetabular components following primary THA.

16,421 primary THAs performed for osteoarthritis between 2000 and 2019 were identified from our institutional total joint registry. Patients received one of 12 contemporary cementless acetabular designs with HXLPE liners. Components were grouped based on ingrowth surface into 4 categories: porous titanium (n=10,952, mean follow-up 5 years), porous tantalum (n=1223, mean follow-up 5 years), metal mesh (n=2680, mean follow-up 6.5 years), and hydroxyapatite (HA) coated (n=1566, mean follow-up 2.4 years). Kaplan-Meier analyses were performed to assess the survivorship free of acetabular revision. A historical series of 182 Harris-Galante-1 (HG-1) acetabular components was used as reference.

The 15-year survivorship free of acetabular revision was >97% for all 4 contemporary cohorts. Compared to historical control, porous titanium (HR 0.06, 95% CI 0.02–0.17, p<0.001), porous tantalum (HR 0.09, 95%CI 0.03–0.29, p<0.001), metal mesh (HR 0.11, 95%CI 0.04–0.31, p<0.001), and HA-coated (HR 0.14, 95%CI 0.04–0.48, p=0.002) ingrowth surfaces had significantly lower risk of any acetabular revision. There were 16 cases (0.1%) of acetabular aseptic loosening that occurred in 8 (0.07%) porous titanium, 5 (0.2%) metal mesh, and 3 (0.2%) HA-coated acetabular components. 7 of the 8 porous titanium aseptic loosening cases occurred in one known problematic design. There were no cases of aseptic loosening in the porous tantalum group.

Modern acetabular ingrowth surfaces and HXLPE liners have improved on historical results at the mid-term. Contemporary designs have extraordinarily high revision-free survivorship, and aseptic loosening is now a rare complication.

At mid-term follow-up, survivorship of contemporary uncemented acetabular components is excellent and aseptic loosening occurs in a very small minority of patients.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 598 - 603
1 May 2022
Siljander MP Gausden EB Wooster BM Karczewski D Sierra RJ Trousdale RT Abdel MP

Aims

The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes.

Methods

We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m2 (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2).


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1103 - 1110
1 Jun 2021
Tetreault MW Hines JT Berry DJ Pagnano MW Trousdale RT Abdel MP

Aims

This study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA).

Methods

From 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 51 - 51
1 Oct 2020
Wooster BM Kennedy NI Mallet KE Taunton MJ Abdel MP Trousdale RT
Full Access

Introduction

Mechanical or corrosive failure of total knee arthroplasties (TKAs) is difficult to diagnose with current laboratory and radiographic analyses. As such, the goal of this study was to determine the mean blood concentration of cobalt, chromium, and titanium in a series of revision TKAs with mechanical implant failure and evaluate whether they facilitated identification of the underlying TKA failure mechanism.

Methods

Serum cobalt, chromium, and titanium levels and synovial fluid characteristics were evaluated in 12 patients (13 aseptic revision TKAs) who underwent revision TKA between 2000 and 2020 at a single academic institution for mechanical implant failure or corrosion. Seventy-five percent were re-revisions of previously revised TKAs. Mean time to revision was 6 years. Modular metallic junctions were present in 100%. Twenty-five percent did not have another in situ total joint arthroplasty, and the remaining patients did not have a metal-on-metal articulation that could lead to elevation in serum metal ion levels. Mean follow-up after the revision TKA was 8 months.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 8 - 8
1 Oct 2020
Wyles CC Maradit-Kremers H Rouzrokh P Barman P Larson DR Polley EC Lewallen DG Berry DJ Pagnano MW Taunton MJ Trousdale RT Sierra RJ
Full Access

Introduction

Instability remains a common complication following total hip arthroplasty (THA) and continues to account for the highest percentage of revisions in numerous registries. Many risk factors have been described, yet a patient-specific risk assessment tool remains elusive. The purpose of this study was to apply a machine learning algorithm to develop a patient-specific risk score capable of dynamic adjustment based on operative decisions.

Methods

22,086 THA performed between 1998–2018 were evaluated. 632 THA sustained a postoperative dislocation (2.9%). Patients were robustly characterized based on non-modifiable factors: demographics, THA indication, spinal disease, spine surgery, neurologic disease, connective tissue disease; and modifiable operative decisions: surgical approach, femoral head size, acetabular liner (standard/elevated/constrained/dual-mobility). Models were built with a binary outcome (event/no event) at 1-year and 5-year postoperatively. Inverse Probability Censoring Weighting accounted for censoring bias. An ensemble algorithm was created that included Generalized Linear Model, Generalized Additive Model, Lasso Penalized Regression, Kernel-Based Support Vector Machines, Random Forest and Optimized Gradient Boosting Machine. Convex combination of weights minimized the negative binomial log-likelihood loss function. Ten-fold cross-validation accounted for the rarity of dislocation events.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 34 - 34
1 Oct 2019
Bingham JS Arthur JR Trousdale RT Lewallen DG Berry DJ Abdel MP
Full Access

Introduction

Pelvic discontinuity is a challenging complication. One treatment option that has garnered enthusiasm is acetabular distraction. This method obtains stability via distraction of the discontinuity and placement of an oversized socket (± augments) and elastic recoil of the pelvis. The aims of this study were to report implant survivorship, radiographic results, clinical outcomes, and complications of acetabular distraction for pelvic discontinuity in the largest series to date.

Methods

We retrospectively identified all revision THAs with a Paprosky 3B defect and pelvic discontinuity between 2005 and 2017. Of the 162 patients, 32 were treated with distraction. The mean distraction achieved was 5mm (range, 3–8mm). In addition to distraction with a hemispherical cup, augments were utilized in 3 and cages in 19. The mean age at revision was 68 years with 75% female. Mean follow-up was 3 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 11 - 11
1 Oct 2019
Wyles CC Paradise CR Masters TL Patel R Abdel MP Trousdale RT Sierra RJ
Full Access

Introduction

Adverse local tissue reactions (ALTR) can result in devastating soft tissue and osseous destruction, while potentially increasing the risk of concomitant periprosthetic joint infection (PJI). The aims of this study were to evaluate cobalt (Co) and chromium (Cr) levels generated in simulators from metal-on-polyethylene (MoP) and ceramic-on-polyethylene (CoP) constructs, and determine their impact on native tissues and PJI risk through evaluation of human adipose-derived mesenchymal stem cells (AMSCs) and Staphylococcus epidermidis isolates.

Methods

Ten hip simulator constructs were assembled with 36-mm high-offset femoral heads, highly cross-linked polyethylene liners, and titanium stems. Five constructs used CoCr femoral heads and five used ceramic. Constructs were submerged in bovine serum (BS) and run for 1,000,000 cycles. Samples of BS were collected and evaluated for CoCr concentration. Various concentrations of CoCr were chosen for further assessment of cytotoxicity and growth impact on AMSCs and S. epidermidis and compared to inert SiO2.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 73 - 73
1 Oct 2019
Fehring KA Wyles CC Trousdale RT
Full Access

Introduction

In the setting of periprosthetic joint infection, the complete removal of implants and cement can be challenging with well-fixed, cemented implants about the knee. This can get especially complex in the setting of long cemented femoral stems. Osteotomies are well described in the proximal femur and tibia for removal of implants and cement. There is little information available on distal femoral osteotomies to facilitate knee implant and retained cement removal.

Methods

We describe a novel anterolateral oblique distal femoral osteotomy for the removal of well-fixed, cemented components during resection knee arthroplasty that preserves vascularity to the osteotomized segment. Cadaveric anatomic vascular injection studies were performed to document vascularity of the osteotomized segment. Clinical examples, and results will be presented.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 35 - 35
1 Oct 2019
Bedard NA Tetreault MW Hanssen AD Lewallen DG Trousdale RT Berry DJ Abdel MP
Full Access

Introduction

Cementation of a new liner into an existing well-fixed acetabular component is common during revision total hip arthroplasties (THAs) for many indications, but most commonly for lack of a modern compatible crosslinked polyethylene liner. However, little is known about the long-term durability of this strategy. The purpose of this study was to evaluate the long-term implant survivorship, risk of complications, clinical outcomes, and radiographic results of cementing a new highly cross-linked polyethylene (HXLPE) liner into a well-fixed acetabular component.

Methods

We retrospectively identified 326 revision THAs where a non-constrained HXLPE liner was cemented into a well-fixed acetabular component. Mean age at revision THA was 63 years, with 50% being female. The most common indications for revision THA were wear and osteolysis (49%), aseptic femoral loosening (35%), and instability (8%). Mean follow-up was 10 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 36 - 36
1 Oct 2019
Bedard NA Brown TS Lewallen DG Trousdale RT Berry DJ Abdel MP
Full Access

Introduction

Many surgeons are reluctant to use a constrained liner at the time of acetabular component revision given concerns this might result in early acetabular component loosening. We hypothesized that with appropriate initial implant stabilization of highly porous acetabular components with supplemental screw fixation, constrained liners could be safely used at the time of acetabular revision.

Methods

We retrospectively identified 148 revision total hip arthroplasties (THAs) where a constrained liner of one design was cemented into a newly placed highly porous acetabular component fixed with supplemental screws (mean 5 screws). Mean age at revision THA was 69 years, with 68% being female. The most common indications for revision were two-stage re-implantation (33%), recurrent dislocation (30%), and aseptic loosening (22% acetabular; 9% acetabular/femoral component). Mean follow-up was 8 years.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 57 - 61
1 Jun 2019
Chalmers BP Mangold DG Hanssen AD Pagnano MW Trousdale RT Abdel MP

Aims

Modular dual-mobility constructs reduce the risk of dislocation after revision total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chromium (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the early- to mid-term serum Co and Cr levels after modular dual-mobility components were used in revision and complex primary THAs, and specifically included patients revised for ALTR.

Patients and Methods

Serum Co and Cr levels were measured prospectively in 24 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. The mean age was 63 years (35 to 83), with 13 patients (54%) being female. The mean follow-up was four years (2 to 7). Indications for modular dual-mobility were prosthetic joint infection treated with two-stage exchange and subsequent reimplantation (n = 8), ALTR revision (n = 7), complex primary THA (n = 7), recurrent instability (n = 1), and periprosthetic femoral fracture (n = 1). The mean preoperative Co and Cr in patients revised for an ALTR were 29.7 μg/l (2 to 146) and 21.5 μg/l (1 to 113), respectively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 67 - 67
1 Oct 2018
Goldman AH Berry DJ Lewallen DG Trousdale RT Sierra RJ Abdel MP
Full Access

Introduction

Historically, the most common indications for re-revision of a total hip arthroplasty (THA) have been aseptic loosening, instability, infection, and peri-prosthetic fracture. As revision implants and techniques have evolved and improved, understanding why contemporary revision THAs fail is important to direct further improvement and innovation. As such, the goals of this study were to determine the implant survivorship of contemporary revision THAs, as well as the most common indications for re-revision.

Methods

We retrospectively reviewed 2568 aseptic revision THAs completed at our academic institution between 2005 and 2015 through our total joint registry. There were 34% isolated acetabular revisions, 18% isolated femoral revisions, 28% both component revisions, and 20% modular component exchanges. The mean age at index revision THA was 66 years, and 46% were males. The most common indications for the index revision THA were aseptic loosening (21% acetabular, 15% femoral, 5% both components), polyethylene wear and osteolysis (18%), instability (13%), fracture (11%), and other (17%). Mean follow-up was 6 years.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 18 - 18
1 Oct 2018
Chalmers BP Mangold DG Hanssen AD Pagnano MW Trousdale RT Abdel MP
Full Access

Introduction

Modular dual-mobility constructs reduce the risk of dislocation after total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chrome (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the mid-term serum Co and Cr levels after modular dual-mobilities used in revision and complex primary THAs, and specifically included patients revised for ALTR.

Methods

Serum Co and Cr levels were measured prospectively in 22 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. Mean age 64 years with 50% female. The mean follow-up was 4 years. Indications for modular dual-mobility were: periprosthetic joint infection treated with 2-stage exchange and subsequent reimplantation (n=8), ALTR revision (n=7), complex primary THA (n=6), and periprosthetic femoral fracture (n=1). Mean preoperative Co and Cr in patients revised for an ALTR were 29.7 µg/L and 21.5 µg/L, respectively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 31 - 31
1 Oct 2018
Wyles CC Robinson WA Maradit-Kremers H Houdek MT Trousdale RT Mabry TM
Full Access

Introduction

Bilateral total knee arthroplasty (TKA) can be performed under a single-anesthetic (SA) or staged under a two-anesthetic (TA) technique. Recently, our institution began piloting a two-surgeon team SA method for bilateral TKA. The purpose of this study was to compare the inpatient costs and clinical outcomes in the first 90 days after surgery between the team SA, single-surgeon SA, and single-surgeon TA approaches for bilateral TKA.

Methods

All primary TKA performed from 2007–2017 by the two participating surgeons for each of the 3 groups of interest were identified: team SA (N=42 patients; 84 knees), single-surgeon SA (N=146 patients; 292 knees), single-surgeon TA (N=242 patients; 484 knees). No patients were lost to follow-up.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 15 - 15
1 Oct 2018
Petis SM Brown TS Pagnano MW Sierra RJ Trousdale RT Taunton MJ
Full Access

Introduction

The influence of surgical approach for total hip arthroplasty (THA) on scar healing and scar perception is unknown. The purpose of this study was to evaluate patients’ perception of their scar following direct anterior (DA) or posterior approach (PA) for THA utilizing validated scar assessment scales.

Methods

Fifty DA and 58 PA THA patients underwent scar assessment using the Patient Observer Scar Assessment Scale (POSAS) and Stony Brook Scar Evaluation Scales (SBSES). Patients were included if they had at least 1-year follow-up, and had no previous surgery or intervention (i.e. radiation) around the assessed hip. The mean age was different between the cohorts (DA 67 vs PA 62 years, p=0.03). Other variables including gender, BMI, Charlson Comorbidity Index, steroid use, diabetes, and smoking were similar (p>0.05 for all comparisons). All patients had subcuticular running closure, secured with skin adhesive glue. Mean time from THA to scar assessment was 3.1 and 3.6 years for the DA and PA groups, respectively (p=0.18).


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 923 - 924
1 Jul 2018
Abdel MP Tibbo ME Stuart MJ Trousdale RT Hanssen AD Pagnano MW


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 925 - 929
1 Jul 2018
Abdel MP Tibbo ME Stuart MJ Trousdale RT Hanssen AD Pagnano MW

Aims

It has been suggested that mobile-bearing total knee arthroplasty (TKA) might lead to better outcomes by accommodating some femorotibial rotational mismatch, thereby reducing contact stresses and polyethylene wear. The aim of this study was to determine whether there is a difference between fixed- and mobile-bearing versions of a contemporary TKA with respect to durability, range of movement (ROM) and function, ten years postoperatively.

Patients and Methods

A total of 240 patients who were enrolled in this randomized controlled trial (RCT) underwent a primary cemented TKA with one of three tibial components (all-polyethylene fixed-bearing, modular metal-backed fixed-bearing and mobile-bearing). Patients were reviewed at a median follow-up of ten years (IQR 9.2 to 10.4).