Kuroda Y Tanaka T Miyagawa T Kawai T Goto K Tanaka S Matsuda S Akiyama H

Objectives

Using a simple classification method, we aimed to estimate the collapse rate due to osteonecrosis of the femoral head (ONFH) in order to develop treatment guidelines for joint-preserving surgeries.

Methods

We retrospectively analyzed 505 hips from 310 patients (141 men, 169 women; mean age 45.5 years (sd 14.9; 15 to 86)) diagnosed with ONFH and classified them using the Japanese Investigation Committee (JIC) classification. The JIC system includes four visualized types based on the location and size of osteonecrotic lesions on weightbearing surfaces (types A, B, C1, and C2) and the stage of ONFH. The collapse rate due to ONFH was calculated using Kaplan–Meier survival analysis, with radiological collapse/arthroplasty as endpoints.


Bone & Joint Research
Vol. 7, Issue 3 | Pages 252 - 262
1 Mar 2018
Nishida K Matsushita T Takayama K Tanaka T Miyaji N Ibaraki K Araki D Kanzaki N Matsumoto T Kuroda R

Objectives

This study aimed to examine the effects of SRT1720, a potent SIRT1 activator, on osteoarthritis (OA) progression using an experimental OA model.

Methods

Osteoarthritis was surgically induced by destabilization of the medial meniscus in eight-week-old C57BL/6 male mice. SRT1720 was administered intraperitoneally twice a week after surgery. Osteoarthritis progression was evaluated histologically using the Osteoarthritis Research Society International (OARSI) score at four, eight, 12 and 16 weeks. The expression of SIRT1, matrix metalloproteinase 13 (MMP-13), a disintegrin and metalloproteinase with thrombospondin motifs-5 (ADAMTS-5), cleaved caspase-3, PARP p85, and acetylated nuclear factor (NF)-κB p65 in cartilage was examined by immunohistochemistry. Synovitis was also evaluated histologically. Primary mouse epiphyseal chondrocytes were treated with SRT1720 in the presence or absence of interleukin 1 beta (IL-1β), and gene expression changes were examined by real-time polymerase chain reaction (PCR).


Bone & Joint Research
Vol. 6, Issue 5 | Pages 331 - 336
1 May 2017
Yamauchi R Itabashi T Wada K Tanaka T Kumagai G Ishibashi Y

Objectives

Ultraviolet (UV) light-mediated photofunctionalisation is known to improve osseointegration of pure titanium (Ti). However, histological examination of titanium alloy (Ti6Al4V), which is frequently applied in orthopaedic and dental surgery, has not yet been performed. This study examined the osseointegration of photofunctionalised Ti6Al4V implants.

Methods

Ti and Ti6Al4V implants were treated with UV light, and the chemical composition and contact angle on the surfaces were evaluated to confirm photofunctionalisation. The implants were inserted into femurs in rats, and the rats were killed two or four weeks after the surgery. For histomorphometric analysis, both the bone–implant contact (BIC) ratio and the bone volume (BV) ratio were calculated from histological analysis and microcomputed tomography data.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 16 - 16
1 May 2017
Furumatsu T Inoue H Miyazawa S Tanaka T Fujii M Ozaki T
Full Access

Background

Meniscus repair can restore the function of torn meniscus in anterior cruciate ligament (ACL)-reconstructed knees. However, few reports investigate the relationship between concurrent meniscus repair with ACL reconstruction and postoperative meniscal position. This study aimed to evaluate the size of the medial meniscus in patients who underwent ACL reconstruction and concomitant all-inside medial meniscus repair.

Methods

This study received the approval of our Institutional Review Board. Twenty patients underwent ACL reconstruction and concurrent medial meniscus repair of a peripheral longitudinal tear using the FasT-Fix meniscal repair device. Medial tibial plateau length (MTPL) and width (MTPW) were determined by radiographic images. We evaluated the Lysholm score, anteroposterior instability (difference in KT-2000 arthrometer measurement), meniscal healing, and magnetic resonance imaging (MRI)-based medial meniscal length (MML) and width (MMW). The healing status of repaired medial meniscus was assessed by 2nd-look arthroscopy.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 14 - 14
1 Apr 2017
Tanaka T Furumatsu T Miyazawa S Fujii M Inoue H Ozaki T
Full Access

Background

Hyaluronan (HA) promotes extracellular matrix (ECM) production and inhibits the activity of matrix degrading enzymes in chondrocytes. The meniscus is composed of the avascular inner and vascular outer regions. Inner meniscus cells have a chondrocytic phenotype compared with outer meniscus cells. In this study, we examined the effect of HA on chondrocytic gene expression in human meniscus cells.

Methods

Human meniscus cells were prepared from macroscopically intact lateral meniscus. Inner and outer meniscus cells were obtained from the inner and outer halves of the meniscus. The proliferative activity of meniscus cells was evaluated by WST-1 assay in the presence or absence of HA (MW = 600–1200 kDa; Seikagaku). Gene expression of SOX9, COL2A1, and COL1A1 was assessed by a quantitative real-time PCR analysis. The effect of HA on the gene expression and cellular proliferation was investigated under the treatment of interleukin (IL)-1α. Meniscal samples perforated by a 2-mm-diameter punch were maintained for 3 weeks in HA-supplemented media. Cultured meniscal samples were evaluated by histological analyses.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 141 - 141
1 Feb 2017
Matsumoto T Takayama K Ishida K Tanaka T Inokuchi T Matsushita T Kuroda R
Full Access

Purpose

Recently, kinematic aligned total knee arthroplasty (TKA) has gained interest for achieving better clinical outcomes over mechanical aligned TKA. The primary goal of kinematic aligned TKA is to position the femoral and tibial components so that the angles and levels of the distal and posterior femoral joint lines and the tibial joint line are each restored to the patient's natural alignment, and not to a neutral limb alignment that is unnatural for most patients. Despite good clinical outcomes reported at short to mid-term follow-up, surgeons should know reasons why this method is useful and safe surgery and carefully assess the long-term outcomes until this new technique is settled as standardized procedure for TKA. The main purpose of the present study was to compare postoperative radiography and clinical scores following kinematic and mechanical aligned TKA.

Methods

Sixty TKAs—30 kinematic and 30 mechanical aligned—were performed in patients with varus-type osteoarthritis using a navigation system. Using postoperative double-leg and single-leg standing long leg radiographs, joint line orientation angle to the floor, conventional mechanical axis (cMA), and true mechanical axis (tMA; line from hip center to the lowest point of calcaneus) were compared between the two groups. One-year after surgeries, range of motion and the patient-derived score of the 2011 Knee Society Score (2011 KSS), which includes four categories: symptoms, patient satisfaction, patient expectations, and functional activities, e.g., walking/standing, standard activities, advanced activities, and discretionary activities, were compared between the two groups


Bone & Joint Research
Vol. 6, Issue 2 | Pages 108 - 112
1 Feb 2017
Itabashi T Narita K Ono A Wada K Tanaka T Kumagai G Yamauchi R Nakane A Ishibashi Y

Objectives

The surface of pure titanium (Ti) shows decreased histocompatibility over time; this phenomenon is known as biological ageing. UV irradiation enables the reversal of biological ageing through photofunctionalisation, a physicochemical alteration of the titanium surface. Ti implants are sterilised by UV irradiation in dental surgery. However, orthopaedic biomaterials are usually composed of the alloy Ti6Al4V, for which the antibacterial effects of UV irradiation are unconfirmed. Here we evaluated the bactericidal and antimicrobial effects of treating Ti and Ti6Al4V with UV irradiation of a lower and briefer dose than previously reported, for applications in implant surgery.

Materials and Methods

Ti and Ti6Al4V disks were prepared. To evaluate the bactericidal effect of UV irradiation, Staphylococcus aureus 834 suspension was seeded onto the disks, which were then exposed to UV light for 15 minutes at a dose of 9 J/cm2. To evaluate the antimicrobial activity of UV irradiation, bacterial suspensions were seeded onto the disks 0, 0.5, one, six, 24 and 48 hours, and three and seven days after UV irradiation as described above. In both experiments, the bacteria were then harvested, cultured, and the number of colonies were counted.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 167 - 167
1 May 2012
Chazono M Tanaka T Soshi S Inoue T Kida Y Nakamura Y Shinohara A Marumo K
Full Access

The use of cervical pedicle screws as anchors in posterior reconstruction surgery has not been widely accepted due to the neurological or vascular injury. We thus sought to investigate the accuracy of free-handed pedicle screw placement in the cervical and upper thoracic spine at the early stage of clinical application.

Eight patients (five males and three females) were included in this study. Mean age was 63 years (31 to 78 years). There were three patients with rheumatoid arthritis, three with cervical fracture-dislocation, and two with spinal metastasis. Twenty-four pedicle screws (3.5 mm diameter: Vertex, Medtronic Sofamordanek) were placed into the pedicle from C2 to T2 level by free-handed technique2). Grade of breaching of pedicle cortex was divided into four groups (Grade 0–3). In addition, screw axis angle (SAA) were calculated from the horizontal and sagittal CT images and compared with pedicle transverse angle (PTA). Furthermore, perioperative complications were also examined.

Our free-handed pedicle screw placement with carving technique is as follows: A longitudinal gutter was created at the lamina-lateral mass junction and then transverse gutter perpendicular to the longitudinal gutter was made at the lateral notch of lateral mass. The entry point of the pedicle screw was on the midline of lateral mass. Medial pedicle cortex through the ventral lamina was identified using the probes to create the hole within the pedicle. The hole was tapped and the screw was gently introduced into the pedicle to ensure the sagittal trajectory using fluoroscopy. In the transverse direction, 22 out of 24 screws (92%) were entirely contained within the pedicle (Grade 0). In contrast, only teo screws (8%) produced breaches less than half the screw diameter (Grade 1). In the sagittal direction, all screws were within the pedicle (Grade 0). Screw trajectories were not consistent with anatomical pedicle axis angle; the mean SAA were smaller than the mean PTA at all levels. The pedicle diameter ranged from 3.9 to 9.2 mm. The mean value gradually increased toward the caudal level. There were no neurological and vascular complications related to screw placement.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 256 - 256
1 Nov 2002
Tsujino A Ochiai N Itoh Y Tanaka T Nishiura Y
Full Access

We performed a new operation for ulnar neuropathy caused by recurrent dislocation at the medial epicondyle.

There were eleven patients, eight men and three women, with an average age of 52 years (24–74 years) at the time of surgery. The mean duration of symptoms was 23 months. The severity of the symptoms was McGowan grade 1 in five patients, grade 2 in five patients, and grade 3 in one patient. The operation consisted of ulnar groove plasty proximal to the cubital tunnel. The ulnar nerve was replaced into this reconstructed groove. The nerve was confirmed to be stable throughout the full range of elbow motion.

The cubital tunnel retinaculum of all patients was hypoplastic and the dislocated portion of the ulnar nerves was hard. One nerve showed severe adhesion around the dislocation site. One patient had a pseudo-neuroma. All patients were relieved of discomfort, and motor and sensory function were recovered. The ulnar nerve in the groove showed neither irritation nor adhesion. In patients with grade 1, symptoms or numbness of the fingers was relieved within three months of the operation. Sensory disturbances in patients with grade 2 symptoms also improved within six months. Grade 2 patients with intrinsic muscle weakness regained normal muscular power, and these with patients with intrinsic muscle atrophy had showed increasing muscular power. The patient with grade 3 symptomes recovered normal sensation after 1 year; clawing of the ring and little fin-gers recovered, and the muscle volume was increased.

Friction ulnar neuropathy has been treated traditionally by anterior transpositon or medial epicondylectomy. The ulnar nerve may become entrapped in scar tissue after these operations. We believe that this anatomical position is optimum for the nerve and that this procedure is essential for treatment of friction neuropathy.