header advert
Results 1 - 20 of 49
Results per page:
Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 209 - 209
1 May 2011
Corten K Naudie D Teo Y Rorabeck C Macdonald S Bourne R Mccalden R
Full Access

Summary Sentence: Cementless solid tri-spiked titanium shells, with a polished inner surface and improved locking mechanism, demonstrated excellent fixation and survivorship at mid-term (minimum 5 years) follow-up.

Introduction: The tri-spiked Reflection cup (Smith & Nephew, Memphis) is a second-generation solid titanium shell with a polished inner surface, no screw holes and an improved locking mechanism. The purpose of this prospective study was to evaluate the minimum 5-year clinical & radiographic results and survivorship of this second-generation acetabular component.

Methods: Between 1997 and 2003, 659 primary THA were performed using the Reflection tri-spiked socket. None of the shells had adjuvant fixation with screws. The mean follow-up time was 7.0 years (5 to 11 yrs). The patients were followed prospectively using validated clinical outcome scores (WOMAC, SF-12, Harris Hip scores) and yearly radiographs.

Results: Twenty-seven patients had died before the minimum 5-year follow-up period. The mean Harris Hip and WOMAC scores were 89 and 79 respectively at last follow-up. Three sockets (0.6%) had been revised: two for infection, one for component malpositioning. No cup was revised for aseptic loosening. Six liners were exchanged: three for residual instability, 3 for wear associated with aseptic loosening of the stem. Radiographic review of remaining cups in-situ identified no cases of loosening and only a small number of cups (< 3%) with any osteolysis. The KM survivorship analysis with revision for any reason, was 97.5% and 97.4% at 5 and 10 years, while survivorship of the acetabular component was 99.8% at 5 and 10 years.

Conclusions: This second-generation cementless solid tri-spiked titanium shell, with a polished inner surface and improved locking mechanism, demonstrated excellent fixation and survivorship at mid-term follow-up.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 533 - 533
1 Oct 2010
Whitehouse M Bhandari R Bourne R Busch C Macdonald S Mccalden R Rorabeck C Shore B
Full Access

Sixty four patients undergoing total hip replacement (THR) were randomized to receive a peri-articular intra-operative multi modal drug injection or to receive no injection. All patients received patient controlled analgesia (PCA) for 24 hours after surgery.

Patients receiving the peri-articular injection showed significantly less PCA consumption 6 hours postoperatively (P< 0.002). The 24 hour PCA requirement post surgery was also less (P< 0.009).

The VAS score for pain on activity in the post anaesthetic care unit (PACU) was significantly less for injected patients (P< 0.04). The VAS satisfaction score for injected patients in the PACU and 4 hours post-operatively showed no statistical difference.

Peri-articular intra-operative injection with multimodal drugs can significantly reduce post-operative patient controlled analgesia requirements and pain on activity in patients undergoing total hip replacement with no apparent increase in risk.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 331 - 331
1 May 2010
Pietri M Lucarini S Mcdonald S Mccalden R Rorabeck C Bourne R
Full Access

Background: Short-term cure rates of two stage revision for infection after TKR are approximately 90%. Little is known about the long-term reinfection-free survival or the mechanical durability of the reimplanted prostheses. The purpose of the study is to evaluate the mid to long term results of this technique with regards to persistence of infection, clinical and radiographic results. The hypothesis is that the success rate of the technique is maintained through long term follow-up, with a low rate of recurrent infection and mechanical implant failure.

Methods: from January 1990 to august 2002, 124 two stage revision TKR for infection were performed at Our Institution with mean follow-up of 9,8 years (5 to 17,5).

The clinical results were evaluated with SF12, WOMAC, and KSCRS performed preoperatively and postoperatively at 5 and 10 years. A radiographic analysis was performed using x-rays of the last available follow-up.

Results: the WOMAC and KSCRS significantly improved at the 5 years follow-up decreasing slightly at 10 years. The SF12 postoperative variation was not significant. The radiographic results showed possible loosening of the tibial or femoral components on 17% and 12% of patients respectively. There were 17 reoperations, 10 of which for persistent infection (85% of survival at 10 years).

Discusssion and conclusion: we are encouraged by the rate of eradication of infection at 10 or more years in these difficult cases. The long term clinical and radiographic results are satisfactory. The study supports the sustained use of this technique for infected total knee arthroplasties.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 251 - 251
1 May 2009
Erak S Bourne R MacDonald S McCalden R Naudie D Rorabeck C
Full Access

There is an increasing trend towards performing a high tibial osteotomy (HTO) with a medial opening wedge technique. Amongst the potential advantages is easier conversion to a total knee replacement (TKR), although literature regarding this is scarce. We report our early clinical and radiological results, along with the technical issues encountered.

From our database, we identified thirty-one patients who had undergone thirty-two TKRs after medial opening wedge HTOs. Clinic and operative records were reviewed, and our database used for knee society scores. Those patients not seen in the last twelve months were reviewed in clinic. All pre- and postoperative radiographs were reviewed. The average age of the patients was fifty-seven years, and the average time from HTO to TKR was 4.5 years.

Difficulties with patella eversion were seen in 12.5%, and the knee balanced easily in 85% of cases. The tibia had minimal deformity in most cases, and all osteotomies were healed at the time of conversion. A stem was used in ten cases, and only if metalwork was removed at the time of conversion (which was done in twenty-three of the thirty-two). Minimum one year follow-up was available for twenty-six patients, with a mean follow-up time of twenty-eight months (range twelve to ninety-three months). The average Knee Society knee score was eighty-eight, function score seventy-five, and total score one hundred and sixty-two. Compared to non-matched group of 1149 primary TKRs (of older average age), the knee score was significantly lower, and there was a higher percentage of patients in the poor category. Poor results correlated strongly to the presence of chronic pain or workers compensation issues, and also to whether the knee had undergone revision HTO prior to TKR.

We conclude that the conversion of a medial opening wedge HTO to a TKR is relatively straightforward technically, and some aspects are easier than performing a TKR after a lateral closing wedge osteotomy (using historical controls). The clinical results appear inferior to that of a TKR performed without a prior osteotomy, although the results in our osteotomy group were skewed by a small group of chronic pain and workers compensation cases.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 238 - 238
1 May 2009
Skutek M Bourne R Burns A Kearns S Krishna G Rorabeck C
Full Access

The purpose of this study was to analyse the twenty to twenty-five year outcomes of one hundred and ninetyfive cemented, matte finish, HD-2 THRs performed in one hundred and sixty-six patients with osteoarthritis of the hip by two surgeons.

The one hundred and ninety-five THRs (one hundred and sixty-six patients) were followed prospectively by clinical assessment using the Harris Hip Score (HHS) and radiographic analysis.

One hundred and forty-nine patients (90%) died with their implant still functioning or still had a successful implant at twenty to twenty-five years follow-up. Ten patients (6%) underwent a revision for aseptic loosening of the acetabular (n=2, 1.2%) or femoral (n=4, 2.4%) component, or both (n=4, 2.4%), that was related to wear-induced osteolysis. 7 (4.2%) patients (eight hips) were lost to follow-up. The mean HHS at the latest follow-up (twenty to twenty-five years) was 88±9. Radiographically, twenty-nine (85%) of the acetabular components were well fixed and four (12%) were probably or possibly loose. Two hips (6%) had probable or possible loosening of the femoral component. At twenty five years, the calculated cumulative survival rate (Kaplan-Meier method) revealed excellent results for revisions (83%±6, any cause) and aseptic loosening (86%±6, femoral component, 93%±3, acetabular component).

The surviving patients had a good mean follow-up and radiographic fixation, proving the exceptional long-term success of this implant.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 249 - 249
1 May 2009
Davoudpour P Bourne R Ieda T Naudie D Rorabeck C
Full Access

The purpose of this study is to compare the long-term clinical results of two total knee replacement designs (the SAL-II mobile-bearing implant and the fixed-bearing Genesis I implant) to see if there are any advantages to the use of a mobile-bearing design in the long-term.

One hundred and ninety-two patients with an age range between twenty-five to ninety who were implanted with either an SAL-II (Group A) or GEN I (Group B) at London Health Sciences Center, University of Western Ontario, were included in the study. Patients with a diagnosis of inflammatory arthritis or with previous high tibial osteotomy were excluded from the study. Demographic data as well as functional outcome measures such as range of motion, knee alignment, specific measures of activities with daily tasks, and composite knee scores such as the Knee Society Clinical Score and Functional Score were collected from the patients’ medical charts and compared. Data was analyzed using SPSS V14.0 statistical software.

Group A included eighty-three mobile-bearing platform arthroplasties in seventy-seven patients. There were forty-one males and thirty-six females. The average age of the patients at the time of surgery was 67.7. Average follow up time was 10.56 years from the date of surgery. Eleven patients were excluded from the study, ten due to previous HTO surgery and one due to rheumatoid arthritis. At latest follow-up, ten patients required revision, and fifteen patients died. Group B included one hundred and thirty-one fixed-bearing knee arthroplasties in one hundred and fourteen patients. There were forty-one males and seventy-three females. The average age of the patients at the time of surgery was 65.8. Average follow up time was 9.58 years from the date of surgery. Twenty five patients were excluded from the study, twenty three patients due to previous HTO surgery and two patients due to rheumatoid arthritis. At latest follow-up, thirteen patients required revision, and twelve patients had died. Include Results and p-values at this stage. No statistically significant difference was found between the groups, either for the knee score (p=0.536), the function score (p=0.115), the range of movement (p=0.718) and number of revisions. Ten years survivorship for mobile bearing group was significantly lower than the fixed bearing group (p=0.005) although this equalised at fifteen years.

This study is the first long-term study that compares the results of the mobile-bearing and fixed bearing designs performed by the same surgeons in the same period of time. The results of this study show no difference in these two designs at a mean of ten years follow-up although fixed bearing design demonstrated better overall ten years survivorship. This difference can be related to the earlier mobile bearing revisions due to aseptic loosening and instability. Mobile bearing designs have yet to prove their theoretical advantage in clinical practice.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2008
Rorabeck C Naudie D Guerin J Parker D Bourne R
Full Access

This study reports the survivorship free of revision or radiographic loosening of one hundred and eight consecutive cemented Miller-Galante unicompartmental knee arthroplasties at a mean ten-year follow-up.

The purpose of this study was to report our experience with the Miller-Galante (MG) unicompartmental knee arthroplasty (UKA) at a mean ten-year follow-up in order to determine if this procedure can provide durable long-term clinical results.

One hundred and eight cemented MG-UKAs in eighty-two patients performed by two surgeons between 1988 and 1997 were reviewed. There were one hundred and six medial and two lateral MG-UKAs performed. Mean age at surgery was sixty-seven years (range, thirty-nine to eighty-seven). There were forty-four males and thirty-eight females. Mean follow-up was ten years (range, five to thirteen). A Kaplan-Meier survivorship analysis using an end-point of revision surgery or radiographic loosening was employed to determine probability of survival at five and ten years.

Of the eighty-two patients (one hundred and eight knees), nine patients (eleven knees) died and one patient (two knees) was lost to follow-up. Eleven patients (eleven knees) were revised at a mean of four years (range, one to nine), and one patient demonstrated radiographic loosening of the tibial component at seven years. Of the eleven revisions, only two required use of revision components. Mean pre-operative and final follow-up Knee Society clinical and functional scores were forty-seven and fifty-three, and ninety and seventy-nine points, respectively. Kaplan-Meier survivorship analysis revealed a probability of survival free of revision or radiographic loosening of 93% at five years and 88% at ten years.

The results of this study demonstrate that the MG-UKA can provide reliable pain relief and restoration of function in selected patients. Our experience has shown that the survivorship of the MG-UKA approaches that of tricompartmental knee arthroplasty, and suggests that UKA may offer the advantage of ease of revision.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 77 - 77
1 Mar 2008
Burnett R Haydon C Rorabeck C Bourne R
Full Access

The results of a randomized controlled clinical trial of ninety patients comparing resurfacing to non-resurfacing of the patella in total knee arthroplasty (TKA) are reported with a minimum of ten-years of follow-up. Using a cruciate retaining hybrid TKA, the outcome measures included Knee Society Clinical Rating scores, functional testing (stair climb and flexion extension torques), patient satisfaction, anterior knee pain, and a patellofemoral specific questionnaire. The results indicated no difference between the groups in all categories. Results at two and ten years postoperatively are compared. This study represents the longest follow-up to date comparing resurfacing to nonresurfacing of the patella.

Patellar resurfacing in TKA remains controversial.

Purpose: To evaluate the results of resurfacing/non-resurfacing of the patella in a randomized controlled clinical trial at a minimum of ten-years of follow-up.

One hundred knees (ninety patients) with osteoarthritis were enrolled in a prospective randomized controlled double-blinded trial using the same posterior cruciate retaining total knee replacement. Patients were randomized to resurfacing or nonresurfacing of the patella. Evaluations were performed preoperatively and yearly to a minimum ten years (range, 10.1–11.5 years) postoperatively. Disease specific (Knee Society Clinical Rating System), functional (stair climbing, knee flex-ion/extension torques, patellar examination) outcomes were measured. Patient satisfaction, anterior knee pain, and patellofemoral questionnaires were completed. Intraoperative grading of the articular cartilage was performed.

No patients were lost to follow-up; forty-six knees remained alive. Nine revisions (9/90-ten percent) were performed – 7/48 (fifteen percent) in the nonresurfaced and 2/42 (five percent) in the resurfaced group. Three knees in the nonresurfaced group were revised to a resurfaced patella for anterior knee pain. One resurfaced patella was complicated by AVN and fracture, requiring revision. No significant difference was found between the groups regarding revision rates, KSCR score, functional, satisfaction, anterior knee pain, patellofemoral, and radiographic outcomes. Intraoperative cartilage quality was not a predictor of outcome.

This study represents the longest follow up to date of a randomized controlled clinical trial to examine patellar resurfacing in TKA. The results showed no significant difference between the groups for all outcome measures at a minimum of ten-years.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 38 - 38
1 Mar 2008
Frost S Summers K Singh B Chess D McCalden R Bourne R Rorabeck C MacDonald S
Full Access

The pathogenesis of osteolysis in failed total hip arthroplasty is not fully understood. The purpose of this study is to identify CD4+CD25+ Regulatory T cells in periprosthetic tissues in failed total hip replacements secondary to osteolysis. Intra-operative tissue samples and peripheral blood were collected from patients undergoing revision total hip arthroplasty surgery. Regulatory T cells were present in the tissues, and significantly increased in the peripheral blood in patients with failed total hips compared to normal controls. Further characterization of these regulatory T cells are warranted as they may play a role in osteolysis in loose total hip replacements.

Osteolysis remains the most common complication following total joint arthroplasty. To date, no authors have investigated the role of CD4+CD25+ regulatory T cells (TREG) participating in the osteolytic pathogenesis. The purpose of this study is to quantitate the presence of TREG cells in periprosthetic tissues in failed total hip replacements secondary to osteolysis.

Fifteen consecutive patients booked for revision total hip arthroplasty secondary to osteolysis were included. Tissue samples were collected: peripheral blood (PB), synovial fluid (SF), synovial tissue (ST), and interface tissue (IT) between the failed component and the bone defect. Total lymphocytes were isolated and analyzed using fluorescent-tagged antibody cell sorting (FACS) for the presence of TREG cells. Frozen sections of ST and IT were analyzed with immunohistochemistry for TREG cells.

TREG cells were significantly upregulated (p< 0.01) in the PB (68%) of revision hip patients compared to normal controls PB (44%). In the synovial tissue (ST) and interface tissue (IT), 57% of the lymphocytes isolated were TREG cells. The presence of TREG cells in the ST and IT were confirmed with immunohistochemistry.

TREG cells are upregulated in the peripheral blood of patients with failed total hips secondary to osteolysis. The TREG cells are also present in the synovial tissue and interface tissue.

Evidence for involvement of regulatory T cells contribute to our understanding of this complex biologic response to artificial wear particles.

Functional studies of these TREG cells are warranted as they are upregulated in patients with loose total hip replacements.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 75 - 75
1 Mar 2008
MacDonald S Marr J Bourne R McCalden R Rorabeck C
Full Access

Fixed bearing and mobile bearing knee designs are both currently used in clinical practice with little evidence- based research available to determine superiority of one system. We performed a prospective, randomized, blinded clinical trial to compare a mobile bearing to two standard fixed bearing implants. A single observer was used to measure all range of motion scores. We evaluated the short and long- term outcomes of the SAL® (mobile bearing) versus the AMK® and Genesis II® (fixed bearings) total knee joint replacements. Minimum two- year follow-up revealed no differences in the outcome measures (WOMAC, SF-12, Knee Society Clinical Rating System).

The purpose of this study was to compare the results between a cruciate retaining mobile bearing total knee (SAL®, Sulzer) and two cruciate retaining fixed bearing total knee prostheses (AMK®, Depuy and Genesis II®, Smith and Nephew).

Ninety patients were randomized to receive a SAL, AMK, or GenesisII prostheses. Patients were evaluated pre-operatively, at three, twelve months and annually thereafter. Patient demographics, radiographs, and multiple outcome measures (WOMAC, SF-12 and the Knee Society Clinical Rating System) were evaluated.

No patients were lost to follow-up. One patient was withdrawn due to dementia before three months, one patient died prior to the two year follow up, and one patient was revised for infection at 6 months leaving eighty-seven patients at an average follow-up of 3.37 years (range 2.91 – 4.44 years). There were no significant differences in any outcome measures or radiographic findings. There were no differences in KSCRS at two years (SAL - 167, AMK – 158, GenesisII – 166). There were no differences in knee flexion at two years (SAL – 117°, AMK – 115°, GenesisII – 118°).

No differences in multiple outcome measures were seen between a cruciate retaining mobile bearing and two cruciate retaining fixed bearing total knee prostheses.

In this prospective randomized clinical trial no differences could be seen between a mobile bearing and two fixed bearing designs at a minimum of two years follow-up. Long-term evaluation will be required to comment on differences in polyethylene wear and implant longevity.

Funding: London Health Sciences Centre Internal Research Fund


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 79 - 79
1 Mar 2008
MacDonald S Marr J Bourne R McCalden R Rorabeck C
Full Access

Fixed bearing and mobile bearing knee designs are both currently used in clinical practice with little evidence- based research available to determine superiority of one system. We performed a prospective, randomized, blinded clinical trial to compare a mobile bearing to two standard fixed bearing implants. A single observer was used to measure all range of motion scores. We evaluated the short and long- term outcomes of the SAL® (mobile bearing) versus the AMK® and Genesis II® (fixed bearings) total knee joint replacements. Minimum two- year follow-up revealed no differences in the outcome measures (WOMAC, SF-12, Knee Society Clinical Rating System).

The purpose of this study was to compare the results between a cruciate retaining mobile bearing total knee (SAL®, Sulzer) and two cruciate retaining fixed bearing total knee prostheses (AMK®, Depuy and Genesis II®, Smith and Nephew).

Ninety patients were randomized to receive a SAL, AMK, or GenesisII prostheses. Patients were evaluated pre-operatively, at three, twelve months and annually thereafter. Patient demographics, radiographs, and multiple outcome measures (WOMAC, SF-12 and the Knee Society Clinical Rating System) were evaluated.

No patients were lost to follow-up. One patient was withdrawn due to dementia before three months, one patient died prior to the two year follow up, and one patient was revised for infection at 6 months leaving eighty-seven patients at an average follow-up of 3.37 years (range 2.91 – 4.44 years). There were no significant differences in any outcome measures or radiographic findings. There were no differences in KSCRS at two years (SAL - 167, AMK – 158, GenesisII – 166). There were no differences in knee flexion at two years (SAL – 117°, AMK – 115°, GenesisII – 118°).

No differences in multiple outcome measures were seen between a cruciate retaining mobile bearing and two cruciate retaining fixed bearing total knee prostheses.

In this prospective randomized clinical trial no differences could be seen between a mobile bearing and two fixed bearing designs at a minimum of two years follow-up. Long-term evaluation will be required to comment on differences in polyethylene wear and implant longevity.

Funding: London Health Sciences Centre Internal Research Fund


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 121 - 122
1 Mar 2008
MacDonald S Marr J Bourne R Rorabeck C
Full Access

The Self Aligning (SAL I) total knee prosthesis (Sulzer, Winterthur) is a first generation cruciate retaining mobile bearing implant allowing unrestricted rotation and up to 5 mm. of translation. A consecutive series of two hundred and three SAL I components in one hundred and sixty- seven patients were implanted between 1990 and 1994 and were reviewed clinically and radiographically. Quality of life outcomes (SF-12 and WOMAC) were also reviewed pre-operatively and regular intervals. This first generation mobile bearing knee implant in this series, continues to function well at a minimum ten years follow-up, with a mechanical failure rate (8%) comparable to fixed bearing designs.

A consecutive series of SAL I total knee arthroplasties were performed between 1990 and 1994 and were reviewed clinically, radiographically and with standardized quality of life outcome tools, including the SF-12 and the Western Ontario MacMaster Osteoarthritis Index (WOMAC).

Patient demographics, radiographs, and multiple validated outcome measures (WOMAC, SF12, Knee Society Clinical Rating System) were evaluated pre-operatively, at three, twelve, and twenty-four months and every two years thereafter.

The series included two hundred and three SAL I implants in one hundred and sixy-sevenpatients. There have been sixty-nine patient deaths (eighty-five procedures), nine patients (eleven procedures) now reside in nursing homes and are unable to return due to medical complications, two patients (three procedures) could not be located. Nine-teen patients/procedures have had revision surgery. Therefore, seventy-six patients (ninety-three procedures) were evaluated with over ten year follow-up (average 10.89 years, range 10.03–13.72). Indications for revision included, sepsis (three), aseptic loosening (eight), instability (two) and poly-wear (six). The KSCRS was assessed for all remaining patients at greater than ten years including pain (45.83), function(65.60), range of motion extension(0.13) and flexion(113.82) as well as the results of the WOMAC (pain-4.36, joint stiffness-2.29, function-18.66, total- 15.92) and SF-12 (Mental-55.37 Physical- 34.99).

The SAL I mobile bearing implant continues to perform comparably to fixed bearing cruciate retaining designs.

This first generation mobile bearing knee implant continues to function well at a minimum ten years follow-up, with a mechanical failure rate (8%) comparable to fixed bearing designs.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 59 - 59
1 Mar 2008
O’Brien J Burnett R Yuan X MacDonald S McCalden R Bourne R Rorabeck C
Full Access

Isolated liner exchange in revision total hip arthroplasty for the treatment of polyethylene wear is an increasingly common surgical procedure. Twenty-four hips underwent this procedure via the direct lateral approach and were prospectively followed clinically and radiographically. Accessible osteolytic lesions were curetted and bone grafted. At a mean follow-up of forty months, a significant clinical improvement was observed. One cup collapsed into an osteolytic lesion postoperatively; all other lesions regressed. No dislocations have occurred. Isolated liner exchange via the direct lateral approach may reduce dislocation rates while avoiding the morbidity associated with the removal of well-fixed components.

The purpose of this study was to evaluate the clinical and radiographic results of isolated liner exchange in revision total hip arthroplasty (THA) for osteolysis and polyethylene wear via the direct lateral surgical approach.

Retention of well-fixed implants avoids unnecessary bone loss at revision surgery. Previous studies report a significant dislocation rate with isolated liner exchange. Revision via the direct lateral surgical approach may reduce the dislocation rate in surgery for acetabular osteolysis.

Twenty-four hips that underwent an isolated liner exchange revision procedure via the direct lateral approach were prospectively followed. Accessible osteolytic lesions were curetted and bone grafted. Harris Hip Score, WOMAC Index, and radiographic analysis were recorded. The area of osteolytic lesions was calculated using a computer imaging technique.

At mean follow-up of forty months, all except one of the osteolytic lesions had regressed in size. Mean Harris Hip scores improved from sixty-nine to eighty-three and WOMAC indices improved from thirty-seven to twenty-four. No dislocations have occurred. One cup collapsed into an osteolytic lesion postoperatively, requiring an acetabular revision procedure.

Isolated liner exchange is a promising technique that avoids the removal of well-fixed acetabular implants. The increased dislocation rate associated with revision THA may be reduced and osteolytic lesions may be debrided and bone grafted through the direct lateral approach.

Isolated liner exchange via the direct lateral approach reduces the dislocation rate in THA. Retention of wellfixed implants and bone grafting is a procedure that preserves bone stock and addresses osteolytic lesions at revision surgery.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 38 - 39
1 Mar 2008
Howard J Hui A Bourne R Rorabeck C MacDonald S McCalden R
Full Access

The purpose of this study was to determine contact patterns in cementless acetabular cups using a novel computed tomography (CT) scan analysis technique. Eighteen embalmed cadaveric hemipelvis specimens were randomly assigned to receive one of three cup designs. A custom CT platform was designed to optimize imaging of the acetabular cups. After cup implantation, specimens were mounted on the platform and imaged in a spiral CT scanner. Contact analysis was preformed using custom-developed imaging software. The hemisphere, dual geometry and spiked cup designs analyzed using this CT analysis technique demonstrate differences in the amount and distribution of bone pros-thesis contact.

The purpose of this study was to determine contact patterns in cementless acetabular cups using computed tomography (CT) scan analysis.

Eighteen embalmed cadaveric hemipelvis specimens were randomly assigned to receive a hemispherical cup, a dual geometry cup, or a spiked cup. After radiographic templating, an experienced orthopaedic team prepared the specimens and implanted the acetabular cups. A custom CT platform was designed to optimize imaging of the acetabular cups. After cup implantation, specimens were mounted on the platform and imaged in a spiral CT scanner. Contact analysis was preformed using custom-developed imaging software. Contact was defined as a bone-prosthesis distance of 0.5 mm or less.

The mean amount of cup contact was 40.4% (SD=8.2%) in the hemisphere group, 24.7% (SD=2.3%) in the dual geometry group, and 29.7% (SD=9.5%) in the spiked group. Colour mapping of the bone-prosthesis gap was used to identify contact/non-contact regions along the acetabular contour for all cup designs.

Preliminary work with this CT analysis technique demonstrates differences in the amount and distribution of contact in the acetabular cup designs. Future work will involve development of an imaging phantom to clarify error, use of the technique with different cup designs and reaming techniques, and comparison of this technique with conventional CT scan techniques.

This study outlines a novel CT analysis technique for quantitatively determining bone-prosthesis contact for cementless acetabular cups.

The hemisphere, dual geometry and spiked cup designs analyzed using this CT analysis technique demonstrate differences in the amount and distribution of bone prosthesis contact.

Funding: Smith and Nephew


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 79 - 80
1 Mar 2008
Comley A MacDonald SJ McCalden RW Rorabeck C Bourne R
Full Access

In recent years articulating cement spacers have been used to treat infected knee arthroplasty. The aim has been to better maintain tissue planes and joint mobility thereby improving second stage re-implantation surgery. Two groups of patients treated for infected knee arthroplasty were reviewed. Twenty-six patients with articulating and forty patients with static antibiotic-impregnated methyl-methacrylate spacers were compared. The articulating spacers demonstrated easier surgical exposure at second stage and improved range of knee motion after re-implantation. There was no compromise in the rate of infection eradication with articulating spacers. Bone loss at revision was independent of spacer type.

To compare the results of patients treated with articulating versus static antibiotic-impregnated spacers for infected knee arthroplasty.

Articulating cement spacers facilitate re-implantation surgery by maintaining tissue planes and joint mobility without compromising joint stability or eradication rate of infection. Patients demonstrate better range of motion and less complications related to the extensor mechanism with the articulated spacer.

Antibiotic impregnated methyl-methacrylate spacers have become a mainstay in two-stage revision arthroplasty for sepsis. It is thought that articulating cement spacers facilitate prosthesis re-insertion by better maintaining tissue planes and joint mobility between stages.

In the articulating group fewer extensile exposure methods were required at second stage prosthesis reimplantation (19% vs 36 %). No tibial tuberosity osteotomies have been required since using the articulating spacer. The articulating group demonstrated a significantly improved range of flexion compared to the static group(106 vs 97 degrees- p=0.045) and had fewer patients with significant loss of extension or quadriceps lag. Eradication of infection was improved in the articulating group (92% vs 82%) but at shorter average follow-up. The need for augments and stabilized prostheses at revision surgery as a measure of bone loss was no different between the groups but was related to the number of prior surgical procedures.

Twenty-six patients treated with articulating spacers were compared to a matched consecutive group of forty patients treated with static spacers. Minimum follow-up was twelve months from second stage re-implantation (average twenty-two months articulating, forty months static)

Funding: No direct funding from any commercial source has been received for this study. The primary author’s fellowship position is partially funded by Smith and Nephew Richards Inc.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 81 - 81
1 Mar 2008
Burnett R Haydon C Rorabeck C Bourne R
Full Access

The results of a randomized controlled clinical trial of ninety patients comparing resurfacing to non-resurfacing of the patella in total knee arthroplasty (TKA) are reported with a minimum of ten-years of follow-up. Using a cruciate retaining hybrid TKA, the outcome measures included Knee Society Clinical Rating scores, functional testing (stair climb and flexion extension torques), patient satisfaction, anterior knee pain, and a patellofemoral specific questionnaire. The results indicated no difference between the groups in all categories. Results at two and ten years postoperatively are compared. This study represents the longest follow-up to date comparing resurfacing to nonresurfacing of the patella.

Patellar resurfacing in TKA remains controversial. Purpose: To evaluate the results of resurfacing/non-resurfacing of the patella in a randomized controlled clinical trial at a minimum of ten-years of follow-up.

One hundred knees (ninety patients) with osteoarthritis were enrolled in a prospective randomized controlled double-blinded trial using the same posterior cruciate retaining total knee replacement. Patients were randomized to resurfacing or nonresurfacing of the patella. Evaluations were performed preoperatively and yearly to a minimum ten years (range, 10.1–11.5 years) postoperatively. Disease specific (Knee Society Clinical Rating System), functional (stair climbing, knee flexion/extension torques, patellar examination) outcomes were measured. Patient satisfaction, anterior knee pain, and patellofemoral questionnaires were completed. Intraoperative grading of the articular cartilage was performed.

No patients were lost to follow-up; forty-six knees remained alive. Nine revisions (9/90-ten percent) were performed – 7/48 (fifteen percent) in the nonresurfaced and 2/42 (five percent) in the resurfaced group. Three knees in the nonresurfaced group were revised to a resurfaced patella for anterior knee pain. One resurfaced patella was complicated by AVN and fracture, requiring revision. No significant difference was found between the groups regarding revision rates, KSCR score, functional, satisfaction, anterior knee pain, patellofemoral, and radiographic outcomes. Intraoperative cartilage quality was not a predictor of outcome.

This study represents the longest follow up to date of a randomized controlled clinical trial to examine patellar resurfacing in TKA. The results showed no significant difference between the groups for all outcome measures at a minimum of ten-years.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 40 - 40
1 Mar 2008
Haydon C Mehin R Rorabeck C Bourne R McCalden R Macdonald S
Full Access

One hundred and thirty-one cemented femoral stems inserted during revision total hip arthroplasty were reviewed to determine component survival. Harris Hip scores and complete radiographs were analysed. Survival at 10.5 years was 86.9%. Radiographically, 76.9% of the remaining components were classified as stable or possibly loose. Chi-square analysis of demographic and surgical factors determined age < 60 years, male gender and stems > 200 mm in length contributed significantly to failure (p < 0.05). Contrary to published results, we found that longer stems were more susceptible to failure. Revision femoral THA to a cemented component is an effective procedure that exhibits good long-term survival.

The purpose of this study was to determine the long-term survival of cemented femoral components in revision total hip arthroplasty (THA) and to identify factors significant to implant failure.

Cemented femoral components demonstrate good long-term survival and remain a suitable option for revision THA for hips with an intact cortical tube.

We report high long-term survival for this increasingly popular procedure, and contradict published results regarding the relationship between stem length and failure.

A consecutive series of one hundred and thirty-one THA revisions using a cemented femoral component were reviewed. Ninety-four hips in eighty-five patients alive > six years post-operatively were studied with a mean follow-up of 10.5 years. Hips excluded from analysis were thirty deceased and seven lost to follow-up before six years post-operatively. Implant success was graded radiographically and by comparing pre-operative to recent Harris Hip scores.

Of the ninety-four hips, fifteen (16%) femoral components were subsequently revised; nine (9.6%) for aseptic loosening, three (3.2%) for periprosthetic fracture, and one (1.1%) for each of stem fracture, instability, and sepsis. Survival at 10.5 years was 86.9% for all reasons and 91.0% for aseptic loosening as an endpoint. 76.9% of the retained components were radiologically classified as stable or possibly loose at follow-up. Factors significant for failure included age at revision < sixty years (p = 0.003), male patients (p = 0.036) and stems > 200 mm in length (p = 0.024).


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 83 - 83
1 Mar 2008
Comley A McCalden R Rorabeck C MacDonald S Bourne R
Full Access

Constrained acetabular components are a useful adjunct for the potentially unstable hip arthroplasty. There have been concerns over implant failure and early acetabular component loosening secondary to the increased implant constraint. We report the results of a constrained ace-tabular component used as treatment for dislocating hips and as prophylaxis against dislocation in high risk primary and revision hip arthroplasty. At average 3.1 years follow-up only one insert of eighty-nine inserted had failed. No cups have demonstrated radiographic or clinical evidence of loosening. We conclude this implant is safe and effective for both the prevention and treatment of hip instability.

To review the effectiveness and durability of a constrained acetabular component used to treat and prevent recurrent dislocation after total hip arthroplasty

Constrained acetabular components of this type provide both an excellent treatment and preventative option in total hip arthroplasty. There is no evidence of accelerated cup loosening and the implant failure rate remains acceptable despite the increased constraint.

Constrained acetabular components have been mainly used as a salvage option for dislocating hip arthroplasty. There have been concerns over implant failure and early acetabular component loosening secondary to the increased implant constraint. Use of this implant can prevent dislocation in high risk patient groups (eg: revision surgery) without compromising implant longevity. This significantly reduces the potential morbidity associated with hip instability.

Eighty-nine patients received the tripolar constrained acetabular component. Fifteen were inserted for recurrent dislocation whilst seventy-two were inserted in patients felt to be at high risk of dislocation (forty-nine for intra-operative instability at revision surgery, twenty-five for primary THA in patients with poor compliance, neurological conditions or deficient abductor mechanism). One implant failed by component dissociation at eighteen months. All other recurrent dislocators remained stable. There was no evidence of accelerated component loosening at medium term review (range twelve – eighty three months, average thirty-seven months)

Radiographic and clinical data was prospectively collected on eighty-nine patients who had the constrained acetabular component inserted.

Funding: The primary author’s fellowship position is partially funded by Smith and Nephew Richards Inc.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 144 - 144
1 Mar 2008
Kearns S Jamal B Burns A Skutek M Bourne R MacDonald S McCalden R Rorabeck C
Full Access

Purpose: The young patient with hip arthritis remains one of the biggest challenges to arthroplasty surgeons. The difficulty of providing a long-lasting total hip arthroplasty (THA) has been clearly documented in the literature. The aim of this study was to assess the outcomes of uncemented THA’s performed in our unit in patients aged under 50.

Methods: In our unit information on all patients is recorded prospectively on an arthroplasty database. From this database we identified 273 uncemented THAs in 237 patients under the age of 50 performed in our unit between 1985 and 2000 with a minimum of 5 year follow up. Outcomes were assessed in terms of 10 and 15-year survival with revision for any reason as the endpoint. Hip scores at routine and most recent follow-up were also reviewed. All surviving implants were radiographically assessed for acetabular wear, component loosening and for the presence of osteolysis.

Results: The mean age of patients at the time of surgery was 41.1 years. 36 patients had bilateral THA. The overall 10 and 15 year survival was 88.7 ± 2.4% and 65.6 ± 4.8 % respectively. Femoral stem survival was significantly higher at 100 % and 98.4 ± 1.6% at 10 and 15 years. Acetabular component survival was 88.6 ± 2.5 % at 10 years and 65.9 ± 4.8 % at 15 years. In unrevised THA’s 56.9% had asymmetric polyethylene wear > 2mm. 2% had definite evidence of acetabular loosening. 25.5% had radiographic evidence of femoral cortical hypertrophy or spot-welds. The mean HHS pre–operatively, at 5 and 10-year follow-up was 46.4 ± 13, 90.7 ± 12.2 and 87.9 ± 14.7 respectively.

Conclusions: Uncemented THA is effective even in young active patients. The main challenges remain ace-tabular polyethylene wear and loosening. Femoral uncemented stems provide long-term functional fixation. Contemporary bearing surfaces in association with such stems may provide long lasting THA’s even in young active patients.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 121 - 121
1 Mar 2008
Shore B Busch C Bhandari R Ganapathy S MacDonald S Rorabeck C Bourne R McCalden R
Full Access

This Blinded Randomized Clinical Trial outlines: how peri-articular intra-operative multimodal analgesia significantly reduces post-operative analgesia requirement. Sixty-four patients undergoing total knee replacement were randomised to receive a peri-articular intra-operative injection containing ropivacaine, ketorolac, epimorphine and epinephrine or nothing. Patients who received the injection demonstrated greater satisfaction and pain relief. Finally, patients in the injected group did not show any signs of cardio and central nervous system toxicity.

Post-operative analgesia can be associated with troublesome side effects. Good peri-operative analgesia facilitates rehabilitation, improves patient satisfaction and may reduce hospital stay. The purpose of this study was to assess a novel cocktail for peri-articular analgesia after total knee replacement.

Sixty-four patients undergoing total knee replacement were randomised to receive a peri-articular intra-operative injection containing ropivacaine, ketorolac, epimorphine and epinephrine or nothing. The anaesthetic analgesic regime was standardised. All patients received patient controlled analgesia (PCA) for twenty-four hours post surgery, followed by standard analgesia. VAS pain scores during activity and at rest and patient satisfaction scores were recorded pre and post operatively and at six week follow up. PCA consumption and overall analgesic requirement were measured.

PCA use at six, twelve and over twenty-four hours post surgery was significantly less in patients receiving the injection (p< 0.01, p=0.016, p< 0.01). Patient satisfaction in PACU and four hours post operation was greater (p=0.016, p=0.013). VAS for pain during activity in PACU and at four hours were significantly less (p=0.04, p=0.007) in the injected group. The average ROM at six weeks was no different. Overall hospital stay and the incidence of wound complications were not different between the two groups.

Peri-articular intra-operative multimodal analgesia significantly reduces post-operative analgesia requirement. Patient satisfaction and pain relief is greater in the injection group. No cardio and central nervous system toxicity was observed.

Our novel cocktail of ketorolac, epimorphine, epinephrine and ropivacaine provides superior pain relief with no adverse side effects.