header advert
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 150 - 157
1 Jun 2021
Anderson LA Christie M Blackburn BE Mahan C Earl C Pelt CE Peters CL Gililland J

Aims

Porous metaphyseal cones can be used for fixation in revision total knee arthroplasty (rTKA) and complex TKAs. This metaphyseal fixation has led to some surgeons using shorter cemented stems instead of diaphyseal engaging cementless stems with a potential benefit of ease of obtaining proper alignment without being beholden to the diaphysis. The purpose of this study was to evaluate short term clinical and radiographic outcomes of a series of TKA cases performed using 3D-printed metaphyseal cones.

Methods

A retrospective review of 86 rTKAs and nine complex primary TKAs, with an average age of 63.2 years (SD 8.2) and BMI of 34.0 kg/m2 (SD 8.7), in which metaphyseal cones were used for both femoral and tibial fixation were compared for their knee alignment based on the type of stem used. Overall, 22 knees had cementless stems on both sides, 52 had cemented stems on both sides, and 15 had mixed stems. Postoperative long-standing radiographs were evaluated for coronal and sagittal plane alignment. Adjusted logistic regression models were run to assess malalignment hip-knee-ankle (HKA) alignment beyond ± 3° and sagittal alignment of the tibial and femoral components ± 3° by stem type.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 55 - 55
1 Oct 2020
Mahan C Blackburn B Anderson LA Peters CL Pelt CE Gililland JM
Full Access

Introduction

Porous metaphyseal cones are increasingly used for fixation in revision total knee arthroplasty (RTKA). Both cemented shorter length stems and longer diaphyseal engaging stems are currently utilized with metaphyseal cones with no clear evidence of superiority. The purpose of this study was to evaluate our experience with 3D printed titanium metaphyseal cones with both short cemented and longer cementless stems from a clinical and radiographic perspective.

Methods

In total 136 3D printed titanium metaphyseal cones were implanted. The mean patient age was 63 and 48% were female. The mean BMI was 33 and the mean ASA class was 2.5. There were 42 femoral cones in which 28 cemented and 14 cementless stems were utilized. There were 94 tibial cones in which 67 cemented and 27 cementless stems were utilized. The choice for stem fixation was surgeon dependent and in general cones were utilized for AORI type 2 and 3 bone defects on the femur and tibia. The most common fixation scenario was short cemented stems on both the femur and tibia followed by cemented stem fixation on the tibia and cementless fixation on the femur. Clinical data such as revision, complication, and PRO was collected at last follow-up (minimum follow-up 1 year). Radiographic analysis included cone bony ingrowth and coronal and sagittal alignment on long-standing radiographs. Descriptive statistics were used to compare demographics between patients who had malalignment (HKA beyond +/− 3 degrees and flexion/extension beyond +/− 3 degrees). Adjusted logistic regression models were run to assess malalignment risk by stem type.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 24 - 30
1 Jun 2020
Livermore AT Erickson JA Blackburn B Peters CL

Aims

A significant percentage of patients remain dissatisfied after total knee arthroplasty (TKA). The aim of this study was to determine whether the sequential addition of accelerometer-based navigation for femoral component preparation and sensor-guided ligament balancing improved complication rates, radiological alignment, or patient-reported outcomes (PROMs) compared with a historical control group using conventional instrumentation.

Methods

This retrospective cohort study included 371 TKAs performed by a single surgeon sequentially. A historical control group, with the use of intramedullary guides for distal femoral resection and surgeon-guided ligament balancing, was compared with a group using accelerometer-based navigation for distal femoral resection and surgeon-guided balancing (group 1), and one using navigated femoral resection and sensor-guided balancing (group 2). Primary outcome measures were Patient-Reported Outcomes Measurement Information System (PROMIS) and Knee injury and Osteoarthritis Outcome (KOOS) scores measured preoperatively and at six weeks and 12 months postoperatively. The position of the components and the mechanical axis of the limb were measured postoperatively. The postoperative range of motion (ROM), haematocrit change, and complications were also recorded.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 24 - 24
1 Oct 2019
Livermore AT Erickson J Hickerson M Peters CL
Full Access

Introduction

Total knee arthroplasty (TKA) reliably improves pain and function in patients with knee osteoarthritis (OA), though a substantial percentage of patients remain unsatisfied. Reasons include the presence of complications, persistent pain, and unmet expectations. The aim of this study was to determine whether the sequential addition of accelerometer-based navigation of the distal femoral cut and sensor-assisted soft tissue balancing changed complication rates, radiographic alignment, or patient-reported outcomes (PROs) compared to TKA performed with conventional instrumentation.

Methods

This retrospective cohort study included 371 TKAs in 319 patients. All surgeries were performed by a single surgeon in sequential fashion using a measured resection technique with a goal of mechanical alignment. The historical control group, utilizing intramedullary guides for distal femoral resection and surgeon-guided soft tissue balancing, was compared to group 1 (accelerometer-based navigation for distal femoral resection, surgeon-guided balancing) and group 2 (navigated femoral resection, sensor-guided balancing). Primary outcome measures were PROMIS scores including physical function computerized adaptive test (PF CAT), and the Global 10 health assessment (including physical, mental, and pain scores), and Knee Injury Osteoarthritis and Outcome Score (KOOS), measured preoperatively and at 6 weeks and 12 months postoperatively. Radiographic measurements included component position and overall mechanical alignment of the limb and were made at 6 weeks by a single examiner from hip to ankle standing films. Charts were reviewed for pre- and postoperative ROM at 6 weeks, polyethylene insert morphology, and postoperative hematocrit change. Complications were recorded, including manipulation under anesthesia and reoperation. Our study was powered to detect a difference of 1 standard deviation in PF CAT score with 100 patients. Statistical analysis was performed by a statistician including t-tests, multivariate regression, and time series plot analyses.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 64 - 69
1 Jul 2019
Wodowski AJ Pelt CE Erickson JA Anderson MB Gililland JM Peters CL

Aims

The Bundled Payments for Care Improvement (BPCI) initiative has identified pathways for improving the value of care. However, patient-specific modifiable and non-modifiable risk factors may increase costs beyond the target payment. We sought to identify risk factors for exceeding our institution’s target payment, the so-called ‘bundle busters’.

Patients and Methods

Using our data warehouse and Centers for Medicare and Medicaid Services (CMS) data we identified all 412 patients who underwent total joint arthroplasty and qualified for our institution’s BPCI model, between July 2015 and May 2017. Episodes where CMS payments exceeded the target payment were considered ‘busters’ (n = 123). Risk ratios (RRs) were calculated using a modified Poisson regression analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 70 - 70
1 Oct 2018
Wodowski AJ Pelt CE Erickson J Anderson M Gililland J Peters CL Duensing I
Full Access

Introduction

Recent studies of novel healthcare episode payment models, such as the Bundled Payments for Care Improvement (BPCI) initiative, have demonstrated pathways for improving value. However, these models may not provide appropriate payments for patients with significant medical comorbidities or complications. The objective of this study was to identify risk factors for exceeding our institution's target payment, the so-called “bundle busters.”

Methods

After receiving an exemption from the Institutional Review Board, we queried our institutional data warehouse for all patients (n=412) that underwent total joint arthroplasty (TJA) of the hip (n=192), knee (n=207), or ankle (n=13), and qualified for our institution's bundled payments model during the study time period (July 2015 – May 2017). Patients with medical conditions that were not well controlled or were potentially optimizable were all sent for preoperative medical optimization prior to surgery. For each 90-day episode, patient characteristics, medical comorbidities, perioperative data, and payments from the Centers for Medicare and Medicaid Services (CMS) were obtained. Episodes where Medicare payments exceeded the target payment were considered “busters”. The busters were older, and had higher comorbidity scores (all, p<0.01). Variables were summarized using descriptive statistics and risk ratios were calculated using a modified Poisson regression analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 57 - 57
1 Oct 2018
Noble PC Stephens S Mathis S Ismaily S Peters CL Berger RA Pulido-Sierra L Lewallen D Paprosky W Le D
Full Access

Introduction

The demands placed upon joint surgeons are perhaps greatest when treating the revision arthroplasty patient, who present with complications demanding skill in diagnosis and evaluation, interpersonal communication and the technical aspects of the revision procedure. However, little information exists identifying which specific tasks in revision arthroplasty are most difficult for surgeons to master, and whether the greatest challenges arise from clinical, cognitive or technical facets of patient treatment. This study was undertaken to identify which tasks associated with revision total knee replacement (TKR) are perceived as most challenging to young surgeons and trainees to guide future efforts in surgical training and curriculum development.

Methods

We developed an online survey instrument consisting of 69 items encompassing pre-operative, intraoperative, and post-operative tasks that preliminary studies identified as the essential components of revision TKR. These tasks encompassed 4 domains: clinical decision-making skills (n=9), interpersonal assessment and communication (n=7), surgical decision-making (n=35) and procedural surgical tasks (n=18). Respondents rated the difficulty of each item on a 5-level Likert scale, with an ordinal score ranging from 1 (“very easy”) to 5 (“very difficult”. The survey instrument was administered to a cohort of 109 US surgeons: 31 trainees enrolled in a joint fellowship program (Fellows) and 78 surgeons who had graduated from a joint fellowship program within the previous 10 years (Joint Surgeons). Using appropriate parametric and non-parametric tests, the responses were analyzed to examine the variation of reported difficulty of each of the 69 items, in addition to the nature of the task (cognitive, surgical, clinical and interpersonal), and differences between Fellows and Surgeons.