header advert
Results 101 - 120 of 159
Results per page:
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 307 - 307
1 May 2010
Pandit H Glynjones S Gundle R Gibbons C Mclardy-Smith P Whitwell D Athanasou N Gill H Murray D
Full Access

Introduction: We report on a group of 20 metal-onmetal resurfaced hips (17 patients) presenting with a soft tissue mass associated with various symptoms; these masses we termed pseudotumours.

Methods: All patients underwent plane radiography; CT, MRI and ultrasound investigations were also performed for some patients. Where samples were available histology was performed. Metal ion levels were measured in six patients and one patient had the metal ion levels in the joint fluid measured.

Results: All patients in this series were female. Presentation was variable; the most common symptom was pain or discomfort in the hip region. Other symptoms included spontaneous dislocation, nerve palsy, a noticeable mass or a rash. In all cases a soft tissue mass was present in the region of the hip, this was either solid or cystic. The common histological features were extensive necrosis and lymphocytic infiltration. The blood cobalt and chromium levels varied considerably between the six patients that had these measurements. The median blood chromium level was 3.8 μg/L (range 0.8 to 23 μg/L) and that for cobalt was 11.5 μg/L (range 2.1 to 15 μg/L). The synovial fluid sample taken from a single joint contained much higher metal levels, 701 μg/L for chromium and 329 μg/L for cobalt. Twelve of the 20 cases have so far required revision to a conventional hip replacement.

Discussion: This complication is best imaged with ultrasound, and is not detected by normal xray. We estimate that about 1% of patients develop a pseudotumour in the first five postoperative years. The cause of these pseudotumours is unknown and is probably multifactorial, further work is required to define this; they may be manifestations of a metal sensitivity response. We are concerned that with time the incidence of these pseudo-tumours will increase.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 274 - 274
1 May 2010
Pandit H Steffen R Gundle R Mclardy-Smith P Marks B Beard D Gill H Murray D
Full Access

Introduction: Although resurfacing hip replacements are widely used there are few little independent outcome data to support this. The aim of this study was to report the 5 year clinical outcome and 7 year survival of an independent series.

Method: 610 Birmingham hip resurfacings were implanted in 532 patients with an average age of 51.8 years (range 16.5–81.6 years) and were followed for between 2 to 8 years; 120 of this series had minimum five year follow-up. Two patients were lost. There were 23 revisions, giving an overall survival of 95% (95% CI 85–99%) at seven years. Fractured neck of femur (n=13) was the most common reason for revision, followed by aseptic loosening (n=4). There were also 3 patients who had failures that were possibly related to metal debris. At a minimum of 5 year follow-up 93% had excellent or good outcome according to the Harris Hip Score. The mean Oxford Hip Score was 16.1 points (SD 7.7) and the mean UCLA activity score was 6.6 points (SD 1.9). There were no patients with definite evidence of radiographic loosening or greater than 10% of neck narrowing.

Discussion: The results demonstrate that with the Birmingham Hip Resurfacing, implanted using the extended posterior approach, the five year survival is similar or better to the reported survival rates for cemented and hybrid THR’s in young patients.

Conclusions: Considering these patients are young and active these results are good and support the use of resurfacing. However, further study is needed to address the early failures; particularly those related to fracture and metal debris.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 367 - 373
1 Mar 2010
Kendrick BJL Longino D Pandit H Svard U Gill HS Dodd CAF Murray DW Price AJ

The Oxford Unicompartmental Knee replacement (UKR) was introduced as a design to reduce polyethylene wear. There has been one previous retrieval study involving this implant, which reported very low rates of wear in some specimens but abnormal patterns of wear in others. There has been no further investigation of these abnormal patterns. The bearings were retrieved from 47 patients who had received a medial Oxford UKR for anteromedial osteoarthritis of the knee. None had been studied previously. The mean time to revision was 8.4 years (sd 4.1), with 20 having been implanted for over ten years. The macroscopic pattern of polyethylene wear and the linear penetration were recorded for each bearing. The mean rate of linear penetration was 0.07 mm/year. The patterns of wear fell into three categories, each with a different rate of linear penetration; 1) no abnormal macroscopic wear and a normal articular surface, n = 16 (linear penetration rate = 0.01 mm/year); 2) abnormal macroscopic wear and normal articular surfaces with extra-articular impingement, n = 16 (linear penetration rate = 0.05 mm/year); 3) abnormal macroscopic wear and abnormal articular surfaces with intra-articular impingement +/− signs of non-congruous articulation, n = 15 (linear penetration rate = 0.12 mm/year). The differences in linear penetration rate were statistically significant (p < 0.001).

These results show that very low rates of polyethylene wear are possible if the device functions normally. However, if the bearing displays suboptimal function (extra-articular, intra-articular impingement or incongruous articulation) the rates of wear increase significantly.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 374 - 379
1 Mar 2010
Kendrick BJL Rout R Bottomley NJ Pandit H Gill HS Price AJ Dodd CAF Murray DW

With medial unicompartmental osteoarthritis (OA) there is occasionally a full-thickness ulcer of the cartilage on the medial side of the lateral femoral condyle. It is not clear whether this should be considered a contraindication to unicompartmental knee replacement (UKR). The aim of this study was to determine why these ulcers occur, and whether they compromise the outcome of UKR.

Case studies of knees with medial OA suggest that cartilage lesions on the medial side of the lateral condyle are caused by impingement on the lateral tibial spine as a result of the varus deformity and tibial subluxation. Following UKR the varus and the subluxation are corrected, so that impingement is prevented and the damaged part of the lateral femoral condyle is not transmitting load. An illustrative case report is presented.

Out of 769 knees with OA of the medial compartment treated with the Oxford UKR, 59 (7.7%) had partial-thickness cartilage loss and 20 (2.6%) had a full-thickness cartilage deficit on the medial side of the lateral condyle. The mean Oxford Knee Score (OKS) at the last follow-up at a mean of four years was 41.9 (13 to 48) in those with partial-thickness cartilage loss and 41.0 (20 to 48) in those with full-thickness loss. In those with normal or superficially damaged cartilage the mean was 39.5 (5 to 48) and 39.7 (8 to 48), respectively. There were no statistically significant differences between the pre-operative OKS, the final review OKS or of change in the score in the various groups.

We conclude that in medial compartment OA, damage to the medial side of the lateral femoral condyle is caused by impingement on the tibial spine and should not be considered a contraindication to an Oxford UKR, even if there is extensive full-thickness ulceration of the cartilage.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1566 - 1574
1 Dec 2009
Glyn-Jones S Pandit H Kwon Y Doll H Gill HS Murray DW

Metal-on-metal hip resurfacing is commonly performed for osteoarthritis in young active patients. We have observed cystic or solid masses, which we have called inflammatory pseudotumours, arising around these devices. They may cause soft-tissue destruction with severe symptoms and a poor outcome after revision surgery. The aim of this study was to determine the incidence of and risk factors for pseudotumours that are serious enough to require revision surgery.

Since 1999, 1419 metal-on-metal hip resurfacings have been implanted by our group in 1224 patients; 1.8% of the patients had a revision for pseudotumour. In this series the Kaplan-Meier cumulative revision rate for pseudotumour increased progressively with time. At eight years, in all patients, it was 4% (95% confidence interval (CI) 2.2 to 5.8). Factors significantly associated with an increase in revision rate were female gender (p < 0.001), age under 40 (p = 0.003), small components (p = 0.003), and dysplasia (p = 0.019), whereas implant type was not (p = 0.156). These factors were inter-related, however, and on fitting a Cox proportional hazard model only gender (p = 0.002) and age (p = 0.024) had a significant independent influence on revision rate; size nearly reached significance (p = 0.08). Subdividing the cohort according to significant factors, we found that the revision rate for pseudotumours in men was 0.5% (95% CI 0 to 1.1) at eight years wheras in women over 40 years old it was 6% (95% CI 2.3 to 10.1) at eight years and in women under 40 years it was 13.1% at six years (95% CI 0 to 27) (p < 0.001).

We recommend that resurfacings are undertaken with caution in women, particularly those under 40 years of age but they remain a good option in young men. Further work is required to understand the aetiology of pseudotumours so that this complication can be avoided.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 414 - 414
1 Sep 2009
Simpson D Pandit H Gulati A Gray H Beard D Price A Murray D Gill H
Full Access

Statement of purpose: The aim of this study is to evaluate different designs of unicompartmental knee replacement (UKR) by comparing the peak von Mises and contact stresses in polyethylene (PE) bearings over a step-up activity.

Summary of Methods: A validated finite element (FE) model was used in this study. Three UKR designs were modelled: a spherical femoral component with a spherical PE bearing (fully-congruent), a poly-radial femoral component with a concave PE bearing (semi-congruent), and a spherical femoral component with a flat bearing (non-congruent).

Kinematic data from in-vivo fluoroscopy measurements during a step-up activity was used to determine the relative tibial-femoral position as a function of knee flexion angle for each model. Medial and lateral force distribution was adapted from loads measured in-vivo with an instrumented implant during a step-up activity. The affect that varying the bearing thickness has on the stresses in the bearing was investigated. In addition, varus-valgus mal-alignment was investigated by rotating the femoral component through 10 degrees.

Summary of Results: Only the fully congruent bearing experienced peak von Mises and contact stresses below the PE lower fatigue limit (17MPa) for the step-up activity (fully congruent PE peak contact stress, 5MPa). The highest PE contact stresses were observed for the semi-congruent and non-congruent designs, which experienced approximately 3 times the PE lower fatigue limit. Peak PE von Mises stresses for the semi-congruent and non-congruent designs were similar, peaking at approximately 25MPa. Peak PE von Mises stresses were ameliorated with increased bearing thickness. Varus-valgus mal-alignment had little effect on the peak stresses in the three UKR designs.

Statement of Conclusions: Fully congruent articulating surfaces significantly reduce the peak contact stresses and von Mises stresses in the bearing. The FE model demonstrates that fully congruent bearings as thin as 2.5mm can be used without increasing the contact stresses significantly. Fully congruent designs can use thinner bearings and enable greater bone preservation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Pandit H Jenkins C Gill H Beard D Marks B Price A Dodd C Murray D
Full Access

Introduction: The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of bearing dislocation confirmed the elevated lateral tibial joint line to be a contributory factor. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from the distal femur nor to over tighten the knee and therefore ensure that the tibial joint line was not elevated. Other modifications to the technique were also introduced including use of a domed tibial component.

Aim: The aim of this study is to compare the outcome of these iterations: the original series [series I], Series II with improved surgical technique and the domed tibial component [Series III].

Method: The primary assessment of outcome was bearing dislocation at one year. One year was chosen as all the dislocations in the first series occurred within a year. In series I, there were 53 knees, in series II 65 knees and in series III 60 knees, all with a minimum of one year follow up.

Results: In series I, there were 6 bearing dislocations (11%) and the average range of movement (ROM) was 110°. In the second series, there were 2 dislocations (3%) and the average ROM was 118°. In the third series, there were no primary dislocations and the average ROM was 125°.

Conclusions: The improved surgical technique and implant design has reduced the dislocation rate to an acceptable level so a mobile bearing can now be recommended for lateral UKR.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 500 - 500
1 Sep 2009
Monk P Pandit H Gundle R Whitwell D Ostlere S Athanasou N Gill H McLardy-Smith P Murray D Gibbons C
Full Access

We report on a group of 20 metal-on-metal resurfaced hips (17 patients) presenting with a soft tissue mass associated with various symptoms. We describe these masses as pseudotumours.

All patients underwent plain radiography and fuller investigation with CT, MRI and ultrasound. Where samples were available, histology was performed. All patients in this series were female. Presentation was variable; the most common symptom was pain or discomfort in the hip region. Other symptoms included spontaneous dislocation, nerve palsy, an enlarging mass or a rash. The common histological features were extensive necrosis and lymphocytic infiltration. Fourteen of the 20 cases (70%) have so far required revision to a conventional hip replacement and their symptoms have either settled completely or improved substantially since the revision surgery. Two of the three bilateral cases have asymptomatic pseudotumours on the opposite side.

We estimate that about 1% of patients develop a pseudotumour in the first five postoperative years after a hip resurfacing. The cause of these pseudotumours is unknown and is probably multi-factorial, further work is required to define this; they may be manifestations of a metal sensitivity response. We are concerned that with time the incidence of these pseudotumours will increase.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 411 - 411
1 Sep 2009
Jenkins C Barker K Pandit H Dodd C Murray D
Full Access

The purpose of this study was to determine if a single physiotherapy intervention would enable patients to kneel following Unicompartmental knee arthroplasty (UKA).

Kneeling is an important functional activity that is frequently not performed after knee arthroplasty, thus affecting a patient’s ability to carry out basic tasks of everyday life. There is however no clinical reason why patients should not kneel and many with proposed knee surgery ask about the possibility of kneeling after their operation.

Sixty adults participated in a prospective randomised controlled trial with blinded assessments. At 6 weeks post-operatively UKA patients were randomised to either the Routine care group where no advice on kneeling was given or to the Kneeling intervention group where participants were taught and given advice on how to kneel and were encouraged to do so. They were re-assessed at 1 year. The primary outcome measure was Question 7 of the Oxford Knee Score which asks the question “Could you kneel down and get up again afterwards?”

Pre-operatively there was no difference in the kneeling ability of the two groups. At 1 year the difference in kneeling ability between the two groups was highly significant (p< 0.05). Spearman’s correlation coefficient showed no significant association between a change in score of Question 7 at 1 year and the following factors; scar position, numbness, range of flexion, arthritic involvement of other joints and pain. Linear regression analysis also confirmed that these factors were not successful in predicting a change in kneeling ability.

This study showed that the single factor predictive of kneeling ability was the physiotherapy intervention provided at 6 weeks post-operatively and it is suggested that kneeling should be incorporated into patient’s post-operative rehabilitation programmes.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Pandit H van Duren B Jenkins C Gill H Beard D Price A Dodd C Murray D
Full Access

Introduction: Treatment options for the young active patient with isolated symptomatic medial compartment OA and pre-existing ACL deficiency are limited. Implant longevity and activity levels may preclude TKA, whilst HTO and unicompartmentasl knee arythroplasty (UKA) are unreliable due to ligamentous instability. UKAs tend to fail because of wear or tibial loosening resulting from eccentric loading. Combined UKA and ACL reconstruction may therefore be a solution.

Method: Fifteen patients with combined ACL reconstruction and Oxford UKA (ACLR group), were matched (age, gender and follow-up period) with 15 patients with Oxford UKA with intact ACL (ACLI group). Prospectively collected clinical and x-ray data from the last follow-up (minimum 3 years, range: 3 – 5) were compared. Ten patients from each group also underwent in-vivo kinematic assessment using a standardised protocol.

Results: At the last follow-up, the clinical outcome for the two groups were similar. One ACLR patient needed revision due to infection. Radiological assessment did not show any significant difference between relative component positions and none of the patients had pathological radiolucencies suggestive of component loosening. Kinematic assessment showed posterior placement of the femur on tibia in extension for the ACLR group, which corrected with further flexion.

Conclusions: The short-term clinical results of combined ACL reconstruction and UKA are excellent. Lack of pathological radiolucencies and near normal knee kinematics suggest that early tibial loosening due to eccentric loading is unlikely.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 426 - 426
1 Sep 2009
McDonnell S Thomas G Rout R Osler S Pandit H Beard D Gill H Dodd C Murray D Price A
Full Access

Aim: The aim of this study was to asses the accuracy of skyline radiographs in the assessment of the patellofemoral joint, when compared to open intraoperative assessment.

Methods: Eighty nine patients undergoing knee replacement surgery were included in the study. Skyline radiographs were obtained preoperatively. These radiographs were assessed and graded by an experienced musculoskeletal radiologist using the Altman and Ahlbäck classifications. The grades were calculated for both the medial and lateral facets of the PFJ. Intraoperative assessment of the Patellofemoral joint was undertaken at the time of surgery. The damage was graded using the modified Collins classification (0: Normal, 1: Superficial damage, 2: Partial thickness cartilage loss, 3: Focal Full thickness cartilage loss < 2cm2, 4: Extensive full thickness cartilage loss < 2cm2). Data was obtained for the Medial Facet, Lateral Facet and Trochlea.

Results: Spearman’s rank correlation coefficient between the radiographic and macroscopic changes within the lateral PFJ were poor with both the Altman 0.22 (p=0.0350) and Ahlbäck 0.24 (p=0.018). The correlation of the medial PFJ was slightly better with a coefficient for Altman 0.42 (P< 0.0001) and Ahlbäck 0.34 (P> 0.001).

Conclusion: In conclusion skyline radiographs provide a poor to moderate preoperative assessment of the degree of osteoarthritis within the patella-femoral joint. This has significant implications for establishing radiographic criteria for planning patella-femoral joint replacement.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 410 - 410
1 Sep 2009
Longino D Hynes S Rout R Pandit H Beard D Gill H Dodd C Murray D Cooper C Javaid M Price A
Full Access

Purpose: The aim of this study is to compare the long-term survival results of TKA in patients under the age of 60, using

revision surgery and

poor functional outcome as the end-points.

Method: From our knee database we identified a cohort of 60 total knee replacements that had been performed over 15 years previously. We identified those who had died, those who had been revised and established the Oxford Knee Score (OKS) for all those still surviving.

Results Using the following endpoint criteria the cumulative 15-year survival was (A) revision surgery alone = 78% (CI 12), (B) revision surgery or an OKS less than or equal to 24 (50% of total OKS) = 63% (CI 13), and (C) revision surgery or moderate pain = 48% (CI 14).

Conclusion The functional survival of TKA in patients under the age of 60 decreases in the second decade following implantation with a significant number of prostheses failing the patient due to knee pain


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Pandit H Jenkins C Beard D Gill H Marks B Price A Dodd C Murray D
Full Access

Introduction: The information in the literature about the relative merits of cemented and cementless unicompartmental knee replacement (UKR) is contradictory, with some favouring cementless fixation while others favouring cemented fixation. Cemented fixations give good survivorship but there is concern about the radiolucency which frequently develops around the tibial component. The exact cause of the occurrence of radiolucency is unknown but according to some, it may suggest suboptimal fixation.

Method: Sixty-two knees (31 in each group) were randomised to receive either cemented or cementless UKR components. The components were similar except that the cementless had a porous titanium and hydroxyappatite (HA) coating. Patients were prospectively assessed by an independent observer pre-operatively and annually thereafter. The clinical assessment included Oxford Knee Score, Knee Society Scores and Tegner activity score. Fluoroscopically aligned radiographs were assessed for thickness and extent of radiolucency under the tibial implant.

Results: At one year there were no differences in the clinical outcome between the groups and there were no loose components. No radiolucencies thicker than 1mm were seen. At one year none of the cementless tibias and 30% of the cemented tibias had complete radiolucencies. One out of 31 cementless (3%) and 12 out of 31 cemented (39%) had partial radiolucencies. This difference between these two groups was high significant (p< 0 0001).

Conclusions: This study clearly demonstrates that the incidence of radiolucency beneath the tibial component is influenced by component design and method of fixation. With identical designs of tibial component none of the cementless components developed complete radiolucences whereas 30% of the cemented components did. We conclude that HA achieves better bone integration than cement.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 406 - 406
1 Sep 2009
Pandit H Glyn-Jones S Gundle R Whitwell D Gibbons C Ostlere S Athanasou N Gill H McLardy-Smith P Murray D
Full Access

Introduction: We report on a group of 20 metal-on-metal resurfaced hips (17 patients) presenting with a soft tissue mass associated with various symptoms; these masses we termed pseudotumours. All patients underwent plane radiography; CT, MRI and ultrasound investigations were also performed for some patients. Where samples were available histology was performed.

Methods: All patients in this series were female. Presentation was variable; the most common symptom was pain or discomfort in the hip region. Other symptoms included spontaneous dislocation, nerve palsy, a noticeable mass or a rash. The common histological features were extensive necrosis and lymphocytic infiltration. Fourteen of the 20 cases (70%) have so far required revision to a conventional hip replacement and their symptoms have either settled completely or improved substantially since the revision surgery. Two of the three bilateral cases have asymptomatic pseudotumours on the opposite side.

Conclusions: We estimate that about 1% of patients develop a pseudotumour in the first five postoperative years after a hip resurfacing. The cause of these pseudotumours is unknown and is probably multi-factorial, further work is required to define this; they may be manifestations of a metal sensitivity response. We are concerned that with time the incidence of these pseudotumours will increase.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1019 - 1024
1 Aug 2009
Grammatopolous G Pandit H Kwon Y Gundle R McLardy-Smith P Beard DJ Murray DW Gill HS

Inflammatory pseudotumours occasionally occur after metal-on-metal hip resurfacing and often lead to revision. Our aim was to determine the severity of this complication by assessing the outcome of revision in these circumstances and by comparing this with the outcome of other metal-on-metal hip resurfacing revisions as well as that of matched primary total hip replacements.

We identified 53 hips which had undergone metal-on-metal hip resurfacing and required revision at a mean of 1.59 years (0.01 to 6.69) after operation. Of these, 16 were revised for pseudotumours, 21 for fracture and 16 for other reasons. These were matched by age, gender and diagnosis with 103 patients undergoing primary total hip replacement with the Exeter implant.

At a mean follow-up of three years (0.8 to 7.2) the outcome of metal-on-metal hip resurfacing revision for pseudotumour was poor with a mean Oxford hip score of 20.9 (sd 9.3) and was significantly worse (p < 0.001) than the outcome for fracture with a mean Oxford hip score of 40.2 (sd 9.2) or that for other causes with a mean Oxford hip score of 37.8 (sd 9.4). The clinical outcome of revision for pseudotumour was also significantly worse (p < 0.001) than the outcome of matched primary total hip replacements. By contrast, the outcome for fracture and other causes was not significantly different from that of matched primary total hip replacements (p = 0.065). After revision for pseudotumour there were three cases of recurrent dislocation, three of palsy of the femoral nerve, one of stenosis of the femoral artery and two of loosening of the component. Five hips required further revision. In three of these there was evidence of recurrent pseudotumour, and one is currently awaiting further revision. The incidence of major complications after revision for pseudotumour (50%) was significantly higher (p = 0.018) than that after revision for other causes (14%).

The outcome of revision for pseudotumour is poor and consideration should be given to early revision to limit the extent of the soft-tissue destruction. The outcome of resurfacing revision for other causes is good.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 469 - 474
1 Apr 2009
Gulati A Pandit H Jenkins C Chau R Dodd CAF Murray DW

Varus malalignment after total knee replacement is associated with a poor outcome. Our aim was to determine whether the same was true for medial unicompartmental knee replacement (UKR). The anatomical leg alignment was measured prospectively using a long-arm goniometer in 160 knees with an Oxford UKR. Patients were then grouped according to their mechanical leg alignment as neutral (5° to 10° of valgus), mild varus (0° to 4° of valgus) and marked varus (> 0° of varus). The groups were compared at five years in terms of absolute and change in the Oxford Knee score, American Knee Society score and the incidence of radiolucent lines.

Post-operatively, 29 (18%) patients had mild varus and 13 (8%) had marked varus. The mean American Knee Society score worsened significantly (p < 0.001) with increasing varus. This difference disappeared if a three-point deduction for each degree of malalignment was removed. No other score deteriorated with increasing varus, and the frequency of occurrence of radiolucent lines was the same in each group.

We therefore conclude that after Oxford UKR, about 25% of patients have varus alignment, but that this does not compromise their clinical or radiological outcome. Following UKR the deductions for malalignment in the American Knee Society score are not justified.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 47 - 47
1 Mar 2009
van Duren B Pandit H Gallagher J Beard D Dodd C Gill H Murray D
Full Access

Introduction: Treatment options for the young active patient with isolated symptomatic medial compartment osteoarthritis and pre-existing anterior cruciate ligament (ACL) deficiency are limited. Implant longevity and activity levels may preclude total knee arthroplasty (TKA), whilst high tibial osteotomy HTO and unicompartmental arthroplasty (UKA) are unreliable due to ligamentous instability. UKA’s tend to fail because of wear or tibial loosening resulting from eccentric loading. Combined UKA and ACL reconstruction may therefore be a solution.

Method: Fifteen patients with combined ACL reconstruction and Oxford UKA (ACLR group), were matched (age, gender and follow-up period) with 15 patients with Oxford UKA with intact ACL (ACLI group). Prospectively collected clinical and x-ray data from the last follow-up (minimum 3 years, range: 3–5) were compared. Ten patients from each group also underwent in-vivo kinematic assessment using a standardised protocol.

Results: At the last follow-up, the clinical outcome for the two groups were similar (ACLR: OKS 46, KSS (objective): 99, ACLI: OKS 43, KSS (objective): 94). One ACLR patient needed revision due to infection. Radiological assessment did not show any significant difference between relative component positions and none of the patients had pathological radiolucencies suggestive of component loosening. Kinematic assessment showed posterior placement of the femur on tibia in extension for the ACLR group, which corrected with further flexion.

Conclusions: The short-term clinical results of combined ACL reconstruction and UKA are excellent. Lack of pathological radiolucencies and near normal knee kinematics suggest that early tibial loosening due to eccentric loading is unlikely. Similarly, wear is unlikely to be a problem because of the wear resistance of mobile bearing devices.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 47 - 48
1 Mar 2009
van Duren B Gallagher J Pandit H Beard D Dodd C Gill H Murray D
Full Access

Introduction: The Oxford unicompartmental knee replacement (UKR) use in the lateral compartment has been associated with a reduced flexion range and increased medial compartment pain than seen with its medial counterpart due to, in part, the inadequacy of a flat tibial tray replacing the domed anatomy of the lateral tibia. A new design incorporating a domed tibial component and a biconcave meniscal bearing has been developed to overcome these problems.

This study reports a clinical comparison of new and old establishing whether this modified implant has maintained the established normal kinematic profile of the Oxford UKR.

Method: Patients undergoing lateral UKR for OA were recruited for the study. Fifty one patients who underwent UKR with the domed design were compared to 60 patients who had lateral UKR with a flat inferior bearing surface. Kinematic evaluation was performed on 3 equal subgroups (n = 20); Group 1-Normal volunteer knees, Group 2-Flat Oxford Lateral UKR’s and Group 3-Domed Oxford Lateral UKR’s. The sagittal plane kinematics of each knee was assessed using videofluoroscopic analysis whilst performing a step up and deep knee bend activity. The fluoroscopic images were recorded digitally, corrected for distortion using a global correction method and analysed using specially developed software to identify the anatomical landmarks needed to determine the Patella Tendon Angle (PTA) (the angle the patella tendon and the tibial axis).

Knee kinematics were assessed by analysing the movement of the femur relative to the tibia using the PTA.

Results: PTA/KFA values, for both devices, from extension to flexion did not show any significant difference in PTA values in comparison to the normals as measured by a 3-way ANOVA. The Domed implant achieved higher maximal active flexion during the lunge exercise than those with a flat implant. Only 33% of the flat UKR’s achieved KFA of 130° or more under load whilst performing a lunge, compared with 75% of domed UKR’s and 90% of normal knees. No flat UKR achieved a KFA of 140° or more, yet 50% of all domed UKR’s did, as did 60% of all normal knees.

Conclusions: There was no significant difference in sagittal plane kinematics of the domed and flat Oxford UKR’s. Both designs had favorable kinematic profiles closely resembling that of the normal knee, suggesting normal function of the cruciate mechanism. The domed knees had a greater range of motion under load compared to the flats, approaching levels seen with the normal knee, suggesting that limited flexion for the flat plateau results from over tightening in high flexion and that this is corrected with the domed plateau. Problems with the second generation of lateral Oxford UKA have been rectified by a new bi-concave bearing without losing bearing stability and normal kinematics.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 185 - 189
1 Feb 2009
Pandit H Jenkins C Beard DJ Gallagher J Price AJ Dodd CAF Goodfellow JW Murray DW

We randomised 62 knees to receive either cemented or cementless versions of the Oxford unicompartmental knee replacement. The implants used in both arms of the study were similar, except that the cementless components were coated with porous titanium and hydroxyapatite. The tibial interfaces were studied with fluoroscopically-aligned radiographs.

At one year there was no difference in clinical outcome between the two groups. Narrow radiolucent lines were seen at the bone-implant interfaces in 75% of cemented tibial components. These were partial in 43%, and complete in 32%. In the cementless implants, partial radiolucencies were seen in 7% and complete radiolucencies in none. These differences are statistically significant (p < 0.0001) and imply satisfactory bone ingrowth into the cementless implants.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 531 - 532
1 Aug 2008
Barker KL Newman MA Pandit H Murray DW
Full Access

Introduction: Metal-on-metal hip resurfacing arthroplasty (HRA) is currently recommended for younger, active patients with high expectations but information about outcomes is limited. Reports concentrate on wear, fracture rates and radiographic appearance, rather than function. Studies that report function do not describe rehabilitation protocols. This data is important to discussions about likely outcomes and restrictions prior to consent and to fully evaluate HRA.

Methods: Consecutive Conserve HRA operations were reviewed 1 year post-surgery. Function was assessed using 3 validated questionnaires; the OHS (Oxford Hip Score), HOOS (Hip Disability and Osteoarthritis Outcome Score) and UCLA Activity Scale. Complications, pain, ROM, muscle strength, single leg stand, walking and stair climbing ability were recorded.

Results: 125 HRA were reviewed (68 right, 57 left hips) in 120 patients (71 male, 49 female) of mean age 56 years. 86.7% recorded no complications, but 20% had pain at 3 months. The median OHS was 15, median UCLA 7 (active) and mean HOOS 82.78%. Operated hip flexors, extensors and abductors were weaker (p=0.000) and hip flexion ROM a mean 94.46 ± 12.71 (55–120) degrees. For 25% walking was limited, 7.6% needed a stick and 10% a stair rail. The OHS correlated with HOOS pain subscale (r=0.812, p=0.000), flexion ROM (r=0.426, p=0.000), hip extensor (r=0.359, p=0.000) and abductor (r=0.424, p=0.000) strength. Pain at 3 months correlated with the HOOS pain subscale (p=0.000, r= 0.503).

Discussion: Although outcomes were generally good with few complications, high levels of function and activity 25% had poor outcomes; with pain, restricted hip flexion, decreased strength, limited walking and functional problems, particularly putting on socks. Pain present at 3 months was associated with pain and worse function at 1 year. It is postulated this sub-optimal recovery may be related to current rehabilitation protocols adopted from THA and not tailored to HRA.