Vol. 102-B, Issue SUPP_5 | Pages 42 - 42
1 Jul 2020
Lotfi N Hughes E McCulloch R Horner C Shepherd D Grover L Nightingale P Davis E
Full Access

Polymethylmethacetate (PMMA) is a bone cement used in over 725,000 primary hip arthroplasties in 2018. Cement integrity is affected by external factors, including temperature, mixing technique and moisture uptake, which can influence cement microstructure. Changes in the cement microstructure may ultimately threaten the survivorship of the implant.

The introduction of enhanced recovery and various local anaesthetic infiltration techniques have been adopted in an attempt to facilitate early mobilisation and reduce length of stay. Our study aims to investigate if the mechanical properties of PMMA are altered with exposure to Ropivacaine LA.

Cements were cured in three separate states (air, serum and serum with LA) and the mechanical properties tested at 24 hours and 28 days. Using Refobacin bone cement provided by ZimmerBIOMET, cylindrical molds (12×6mm) were constructed with a split-mold. The LA used was 2mg/ml Ropivacaine hydrochloride solution. Using pilot data, this study was powered to 80% and a sample size of 10 per group (n=60) was calculated.

Cement samples were subjected to compressive loading using a universal testing apparatus (Zwick/Roell). Yield-strength and modulus values were extracted from the respective stress versus strain curves. Significant differences were determined by one-way anova for each time point, and Bonferroni post-hoc testing to determine significance between actual groups.

At 24-hours there were no significant differences in strength or modulus between groups. At 28-day strength and modulus increased in all groups. Compared to the air group, both serum and LA groups show a significant decrease in compressive strength. The modulus for the LA group is significantly less stiff compared to the air group.

The results suggest that the initial exposure to LA has a significant impact on the physical properties of the PMMA. We propose increased awareness of the potential effects this may have on the longevity and survivorship of cemented implants.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 44 - 44
1 May 2018
Lotfi N Thangarj R Fischer B Fenton P
Full Access

Introduction

Fractures of the distal tibia can be challenging to manage. Numerous surgical techniques have been utilised in managing these however there remains debate as to the optimum method of fixation. This study aims to assess the surgical outcomes and PROMs of patients with distal tibial fractures managed with intramedullary-nails or ring fixation.

Methods

This is a retrospective study of patients with closed distal tibial fractures managed between 01/01/2013–31/12/2016. Adult patients admitted with closed fracture of the distal tibia fixed with an intramedullary-nail or circular-frame were included in the study. Primary outcomes were time of union, alignment of tibia post-operatively and the results of two validated PROMs (Kujala knee score and Olerud and Molander Ankle Score).