header advert
Results 21 - 40 of 58
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 39 - 39
1 Jan 2016
Higashi H Kaneyama R Shiratsuchi H Oinuma K Miura Y Tamaki T Jonishi K Yoshii H Lee K
Full Access

(Introduction)

In Total Knee Arthroplasty (TKA), closed drains have been conventionally used to prevent hematoma. Recently reported “no-drain” methods have been demonstrated to be safe and effective, especially for decreasing hemorrhage. However, there has been no report of a major study on a no-drain method in simultaneous bilateral TKA, only a few small studies. Therefore, this study evaluated the efficacy of no-drain placement in simultaneous bilateral TKA.

(Methods)

Our study included 75 patients (150joints) with preoperative hemoglobin(Hb) level of at least 11.0 g/dl who underwent simultaneous bilateral TKA performed by the same surgeon in our department between January 2012 and December 2013.

There were 12men and 63women, of average age 70.7 ± 7.9years (mean ± SD) and BMI 25.6± 3.8 (mean ± SD). Among them 72 patients had knee osteoarthritis and 3 patients had rheumatoid arthritis. The patella was not replaced in any of the cases. TKAs were performed separately on each knee. A tourniquet was applied between the initial skin incision and the postoperative dressing, and 1000 mg of tranexamic acid was injected into each joint after wound closure.


We compared the ceiling effects of two patient-rating scores, the Disability of the Arm, Shoulder and Hand (DASH) and Patient-Rated Wrist Evaluation (PRWE), and a physician-rating score, the Modified Mayo Wrist Score (MMWS) in assessing the outcome of surgical treatment of an unstable distal radial fracture. A total of 77 women with a mean age of 64.2 years (50 to 88) who underwent fixation using a volar locking plate for an unstable distal radial fracture between 2011 and 2013 were enrolled in this study. All completed the DASH and PRWE questionnaires one year post-operatively and were assessed using the MMWS by the senior author. The ceiling effects in the outcome data assessed for each score were estimated.

The data assessed with both patient-rating scores, the DASH and PRWE, showed substantial ceiling effects, whereas the data assessed with MMWS showed no ceiling effect.

Researchers should be aware of a possible ceiling effect in the assessment of the outcome of the surgical treatment of distal radial fractures using patient-rating scores. It could also increase the likelihood of a type II error.

Cite this article: Bone Joint J 2015;97-B:1651–6.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_11 | Pages 23 - 23
1 Oct 2015
Lee K Clegg P Comerford E Canty-Laird E
Full Access

Introduction

Tendon is prone to degeneration through ageing and injury and current therapies are largely ineffective. The recent identification of a cell population within tendon with stem cell-like characteristics holds potential for regeneration of tendon. The local stem cell environment (niche) is important for stem cell maintenance and function. This study aims to characterize extracellular matrix (ECM) components of the stem cell niche in equine tendon, which is prone to age-related degeneration and rupture.

Materials and Methods

Putative tendon stem cells (TSCs) were isolated from equine superficial digital flexor tendon by low-density plating and differential adhesion to fibronectin. Cells were analysed by flow cytometry using antibodies to mesenchymal stem cell markers, as well as qRT-PCR for stem cell and tenogenic markers. The multipotency of cells was assessed using tri-lineage differentiation assays. ECM components of the tenocyte and TSC niche were analysed using radio-isotope labelling, immunohistochemistry and histology.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 229 - 234
1 Feb 2015
Choi W Lee HJ Kim D Lee C Lee BG Kim J Lee K

We performed a retrospective study to determine the effect of osteoporosis on the functional outcome of osteoporotic distal radial fractures treated with a volar locking plate. Between 2009 and 2012 a total of 90 postmenopausal women with an unstable fracture of the distal radius treated with a volar locking plate were studied. Changes in the radiological parameters of 51 patients with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 (sd 0.56)) were not significantly different from those in 39 patients without osteoporosis (group 2, mean age 61.1, mean T-score –1.72 (sd 0.57)). The mean Disabilities of the Arm, Shoulder and Hand (DASH) score at final follow-up was 11.5 (sd 12.2) in group 1 and 10.5 (sd 13.25) in group 2. The mean modified Mayo wrist score at final follow-up was 79.0 (sd 14.04) in group 1 and 82.6 (sd 13.1) in group 2. However, this difference was not statistically significant (p = 0.35 for DASH score, p = 0.2 for modified Mayo wrist score). Univariable and multivariable logistic regression analysis showed that only the step-off of the radiocarpal joint was related to both a poor DASH and modified Mayo wrist score. Pearson’s correlation coefficient showed a weak negative relationship only between the T-score and the change in volar tilt (intraclass coefficient –0.26, p = 0.02).

We found that osteoporosis does not have a negative effect on the functional outcome and additional analysis did not show a correlation between T-score and outcome.

Cite this article: Bone Joint J 2015;97-B:229–34.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 88 - 93
1 Jan 2014
Venkatesan M Northover JR Wild JB Johnson N Lee K Uzoigwe CE Braybrooke JR

Fractures of the odontoid peg are common spinal injuries in the elderly. This study compares the survivorship of a cohort of elderly patients with an isolated fracture of the odontoid peg versus that of patients who have sustained a fracture of the hip or wrist. A six-year retrospective analysis was performed on all patients aged > 65 years who were admitted to our spinal unit with an isolated fracture of the odontoid peg. A Kaplan–Meier table was used to analyse survivorship from the date of fracture, which was compared with the survivorship of similar age-matched cohorts of 702 consecutive patients with a fracture of the hip and 221 consecutive patients with a fracture of the wrist.

A total of 32 patients with an isolated odontoid fracture were identified. The rate of mortality was 37.5% (n = 12) at one year. The period of greatest mortality was within the first 12 weeks. Time made a lesser contribution from then to one year, and there was no impact of time on the rate of mortality thereafter. The rate of mortality at one year was 41.2% for male patients (7 of 17) compared with 33.3% for females (5 of 15).

The rate of mortality at one year was 32% (225 of 702) for patients with a fracture of the hip and 4% (9 of 221) for those with a fracture of the wrist. There was no statistically significant difference in the rate of mortality following a hip fracture and an odontoid peg fracture (p = 0.95). However, the survivorship of the wrist fracture group was much better than that of the odontoid peg fracture group (p < 0.001). Thus, a fracture of the odontoid peg in the elderly is not a benign injury and is associated with a high rate of mortality, especially in the first three months after the injury.

Cite this article: Bone Joint J 2014;96-B:88–93.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 452 - 452
1 Dec 2013
Lee Y Nho J Lee K Ha Y Koo K
Full Access

Background:

Two-stage reconstruction, reimplantation after removal of an infected prosthesis, has been considered to be the gold standard for treatment of infected hip arthroplasty. However, during the removal of a well-fixed femoral stem, the proximal femur can be damaged and a sequestrum can be formed, which might lead to chronic osteomyelitis and difficulty in reimplantation. We wanted to determine whether infection after hip arthroplasty can be treated without removal of a well-fixed stem.

Materials and Methods:

We treated 19 patients who had an infection after hip replacement, but a well-fixed cementless stem, with 2-stage reconstruction. At the first stage, we removed the acetabular cup, the liner and the head, but not the stem. We then implanted a cup of cement spacer. After control of infection, we reimplanted the acetabular component and head.


Severe hallux valgus deformity is conventionally treated with proximal metatarsal osteotomy. Distal metatarsal osteotomy with an associated soft-tissue procedure can also be used in moderate to severe deformity. We compared the clinical and radiological outcomes of proximal and distal chevron osteotomy in severe hallux valgus deformity with a soft-tissue release in both. A total of 110 consecutive female patients (110 feet) were included in a prospective randomised controlled study. A total of 56 patients underwent a proximal procedure and 54 a distal operation. The mean follow-up was 39 months (24 to 54) in the proximal group and 38 months (24 to 52) in the distal group. At follow-up the hallux valgus angle, intermetatarsal angle, distal metatarsal articular angle, tibial sesamoid position, American Orthopaedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal score, patient satisfaction level, and complications were similar in each group. Both methods showed significant post-operative improvement and high levels of patient satisfaction. Our results suggest that the distal chevron osteotomy with an associated distal soft-tissue procedure provides a satisfactory method for correcting severe hallux valgus deformity.

Cite this article: Bone Joint J 2013;95-B:510–16.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 14 - 14
1 Oct 2012
Wong K Kumta S Tse L Ng W Lee K
Full Access

CT and MRI scans are complementary preoperative imaging investigations for planning complex musculoskeletal bone tumours resection and reconstruction. Conventionally, tumour surgeons analyse two-dimensional (2-D) imaging information, mentally integrate and formulate a three-dimensional (3-D) surgical plan. Difficulties are anticipated with increase in case complexity and distorted surgical anatomy. Incorporating computer technology to aid in this surgical planning and executing the intended resection may improve precision. Although computer-assisted surgery has been widely used in cranial biopsies and tumour resection, only small case series using CT-based navigation are recently reported in the field of musculoskeletal tumor surgery. We investigated the results of CT/MRI image fusion for Computer Assisted Tumor Surgery (CATS) with the help of a navigation system.

We studied 21 patients with 22 musculoskeletal tumours who underwent CATS from March 2006 to July 2009. A commercially available CT-based spine navigation system (Stryker Navigation; CT spine) was used. Of the 22 patients, 10 were males, 11 were females, and the mean age was 32 years at the time of surgery (range, 6–80 years). Five tumours were located in the pelvis, seven sacrum, eight femurs, and two tibia. The primary diagnosis was primary bone tumours in 16 (3 benign, 13 sarcoma) and metastatic carcinoma in four. The minimum follow-up was 17 months (average, 35.5 months; range, 17–52 months). Preoperative CT and MRI scan of each patient were performed. Axial CT slices of 0.0625mm or 1.25mm thickness and various sequences of MR images in Digital Imaging and Communications in Medicine (DICOM) format were obtained. CT and MR images for 22 cases were fused using the navigation software. All the reconstructed 2-D and 3-D images were used for preoperative surgical planning. The plane of tumour resection was defined and marked using multiple virtual screws sited along the margin of the planned resection. We also integrated the computer-aided design (CAD) data of custom-made prostheses in the final navigation resection planning for eight cases.

All tumour resections could be carried out as planned under navigation guidance. Navigation software enabled surgeons to examine all fused image datasets (CT/MRI scans) together in two spatial and three spatial dimensions. It allowed easier understanding of the exact anatomical tumor location and relationship with surrounding structures. Intraoperatively, image guidance with the help of fusion images, provided precise visual orientation, easy identification of tumor extent, neural structures and intended resection planes in all cases. The mean time for preoperative navigation planning was 1.85 hours (1 to 3.8). The mean time for intraoperative navigation procedures was 29.6 minutes (13 to 60). The time increased with case complexity but lessened with practice. The mean registration error was 0.47mm (0.31 to 0.8). The virtual preoperative images matched well with the patients' operative anatomy. A postoperative superficial wound infection developed in one patient with sacral chordoma that resolved with antibiotic whereas a wound infection in another with sacral osteosarcoma required surgical debridement and antibiotic. After a mean follow-up of 35.5 months (17–52 months), five patients died of distant metastases. Three out of four patients with local recurrence had tumors at sacral region. Three of them were soft tissue tumour recurrence. The mean functional MSTS score in patients with limb salvage surgery was 28.3 (23 to 30). All patients (except one) with limb sparing surgery and prosthetic reconstruction could walk without aids.

Multimodal image fusion yields hybrid images that combine the key characteristics of each image technique. Back conversion of custom prosthesis in CAD to DICOM format allowed fusion with navigation resection planning and prosthesis reconstruction in musculoskeletal tumours. CATS with image fusion offers advanced preoperative 3-D surgical planning and supports surgeons with precise intraoperative visualisation and identification of intended resection for pelvic, sacral tumors. It enables surgeons to reliably perform joint sparing intercalated tumor resection and accurately fit CAD custom-made prostheses for the resulting skeletal defect.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 37 - 37
1 Jun 2012
Tang N Hung V Yeung H Liao C Lam T Lee K Ng B Cheng J
Full Access

Introduction

Genetic predisposition is a key causal factor in adolescent idiopathic scoliosis (AIS), which is the most common form of spinal deformity. However, common quantitative genetic effect estimates such as hereditability have not been fully evaluated and reported for this disorder. We aimed to determine the sibling recurrent risk and hereditability of AIS in first-degree relatives of 513 Chinese patients with this disorder.

Methods

Family members of 513 Chinese patients with AIS attending a scoliosis clinic were assessed. A diagnosis of AIS was made with the criteria of Cobb angle greater than 20°. The evaluation included clinical assessment and physical examination in a health screening centre by medical doctors with use of forward bending test. Any positive screening cases were referred to a scoliosis clinic for follow-up spinal radiograph. All radiographs were assessed by an orthopaedic surgeon in the scoliosis clinic. A population prevalence of scoliosis was obtained from the data of a territory-wide screening campaign. The prevalence of AIS among siblings of probands was measured both overall and divided by sex of siblings. The sibling recurrent risk (λs) was calculated for male and female siblings separately with reported population incidence of AIS.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 17 - 17
1 Jun 2012
Yeung H Lam T Liu Z Tam E Sun G Lee K Qiu Y Cheng J
Full Access

Introduction

Despite extensive research, the cause of adolescent idiopathic scoliosis (AIS) is still largely unclear. Girls with AIS tend to be taller and leaner, and have a lower body-mass index (BMI) and lower bone mass, than do healthy girls. Recent MRI studies have shown the presence of relative anterior spinal overgrowth in girls with AIS. The lower bone mineral status and BMI could be related to dysfunctional central regulation pathway of growth, bodyweight, and bone metabolism. Following several interesting reports on the role of leptin in regulation of the above pathway in animals and human beings, our recent study has shown a low leptin concentration in girls with AIS girls compared with healthy adolescents. This finding leads to our new hypothesis that abnormal leptin bioavailability could be associated with the lower bodyweight, lower bone mineral density, and relatively disproportional endochondral skeletal growth in AIS. This study aimed to investigate the leptin bioavailability in girls with AIS.

Methods

53 girls with AIS and 27 healthy girls (aged 11–16 years) were recruited in this preliminary study. Clinical and anthropometric data were obtained. Blood samples were obtained for ELISA of leptin and soluble leptin receptor (sOB-R). Independent Student's t test and multivariate regression were used in group comparison.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 53 - 53
1 Jun 2012
Lam T Hung V Yeung H Yu F Chan C Ng B Lee K Qin L Cheng J
Full Access

Introduction

Adolescent idiopathic scoliosis (AIS) is associated with low bone mineral density, which could be related to its etiopathogenesis. Apart from bone density, bone micro-architectures are equally important for better understanding of disease initiation and progression in AIS. Quantitative assessment of bone quality is hampered by the invasive nature of investigations, until recently when the high-resolution pQCT (XtremeCT) became available for revolutionary in-vivo microimaging and derivation of bone micro-architectural parameters. Our objective was to use this powerful instrument to study bone qualities in AIS and compare findings with those from healthy controls.

Methods

48 girls with AIS and 84 sex-matched healthy controls were recruited. Cobb angle was measured with standing radiographs, and imaging of the non-dominant distal radius was captured with XtremeCT according to a standard protocol.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 54 - 54
1 Jun 2012
Lam T Hung VY Yeung H Chu W Ng B Lee K Qin L Cheng J
Full Access

Introduction

The main challenge in management of adolescent idiopathic scoliosis (AIS) is to predict which curve will progress so that appropriate treatment can be given. We previously reported that low bone mineral density (BMD) was one of the adverse prognostic factors for AIS. With advancement in imaging technology, quantitative ultrasound (QUS) becomes a useful method to assess bone density and bone quality. The objective of this study was to assess the role of QUS as a radiation-free method to predict curve progression in AIS.

Methods

294 girls with AIS were recruited at ages 11–16 years and followed up until skeletal maturity. 269 age-matched healthy girls were recruited as controls. They provided the normal reference for calculation of Z score for QUS parameters. QUS measurements, including BUA (broadband ultrasound attenuation), VOS (velocity of sound) and SI (stiffness index) of the calcaneum, BMD of femoral neck, menarche history, ages, and Cobb angle of the major curve were recorded at baseline as independent variables. The predictive outcome was curve progression defined as an increase of Cobb angle of 6° or more. Logistic regression model and the ROC curve were used for statistical analysis.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 412 - 412
1 Nov 2011
Kim Y Kim J Huh W Lee K
Full Access

Although total knee arthroplasty (TKA) has been a reliable procedure providing durable pain relief, polyethylene (PE) wear remains a major limitation of the long-term success of TKA. One potential method of lowering PE wear in TKA is to use oxidized zirconium (OxZr)-bearing surface. Although wear simulating testing of an OxZr counter surface of femoral component produced less PE wear and fewer particles than did cobalt-chrome (Co-Cr) counter surface of femoral component [1–4], this finding has not been demonstrated in vivo to our knowledge.

We measured in vivo PE wear by isolating and analyzing PE wear particles in synovial fluid from wellfunctioning TKA [5]. The purpose of the current study was to determine the size, shape, and amount of PE wear particles isolated from synovial fluid of patients who underwent a bilateral simultaneous TKA prosthesis, but different materials of femoral components.

We performed a bilateral simultaneous TKA in 100 patients (200 knees) who received an OxZr femoral component in one knee and a Co-Cr femoral component in the other. Mean age was 55.6 (44–60) years. Synovial fluid was obtained from 28 patients (56 knees) who had undergone a simultaneous bilateral TKA under completely sterile conditions at one or two years after the operation. Randomization to an OxZr or Co-Cr femoral component was accomplished with use of a sealed study number envelope, which was opened in the operating room before the skin incision had been made. After the opening the randomization envelope, the first knee received prosthesis indicated by the envelope (OxZr or Co-Cr component) and the contralateral (second TKA) knee received the other prosthesis (OxZr or Co-Cr component).

All operations were performed by one surgeon using the same design of total knee prosthesis: Genesis II (Smith and Nephew, Memphis, Tennessee). Only the material of the femoral component differed between two groups. The preoperative diagnosis was osteoarthritis in all patients. Preoperative and post operative KS and HSS knee scores, KS functional scores and UCLA activity scores were evaluated.

The amount of polyethylene wear particles in the aspirated synovial fluid sample was analyzed by thermogravimetic analysis (TGA) using a TGA instrument (TGA/SDTA 84le model, Mettler Toledo CO., Greifensee, Switzerland). The weight of the sample solution was measured before and after removing the organic content by heating the sample solution. The sample solution was casted onto petri dishes. The petri dish was covered and kept in a dry oven at 60°C for 2 days. While the sample solution was kept in a dry oven for 2 days, a small hole was made on the cover of the petri dish to allow water to evaporate slowly for 2 days. After this procedure, the cover of petri dish was removed and TGA sample was dried at 60°C for another 2 days. After the sample was completely dried out, the dried sample was measured using analytical balance.

TGA was used to determine the weight change profiles of polyethylene subject to heating under a nitrogen atmosphere. The nitrogen flow rate was kept constant at 50mL per minute. TGA data were taken at heating rate as 5°C per minute in the temperature range of 20° to 1000°C. The weight loss data were recorded as a function of time and temperature using special software in computer. When the temperature reached to the point of decomposition of the sample, the sample started to lose weight. By calculating the weight of the sample around the temperature which led to start to decomposition, real amount of polyethylene in the sample was measured. The size and shape of PE particles were examined using scanning electron microscopy (JSH-6360A model, Jeol Co., Tokyo, Japan). The samples were coated using a platinum sputtering machine for 20 sec.

ANOVA, nonparametric chi square test, nonpaired t-test and Mann-Whitney U-test were used for statistical analyses. Differences of P< 0.05 were considered statistically significant.

Mean preoperative KS (27.5 vs 27.2 points) scores, HSS (51.1 vs 51.2 points) knee scores, KS functional scores (55.4 vs 55.4 points) and UCLA activity scores (2.8 vs 2.8 point) were not significantly different between two groups. Mean postoperative KS (93 vs 92 points), HSS knee scores (90 vs 89 points), KS functional scores (78 vs 78 points), and UCLA activity scores (7.8 vs 7.8) were not significantly different. Mean weight of the polyethylene particles was 0.0219 g (SD, 0.0058) in the Co-Cr femoral component groups and it was 0.0214 g (SD, 0.005) in the OxZr group. This difference was not significant (P=0.711139, paired t-test). The size of particles was not different between the two groups. Also, shape of particles was not different between the two groups.

Under the condition and the duration of this study in this specific group of patients, TKA with OxZr or Co-CR femoral knee component had excellent clinical and radiographic outcomes with no osteolysis. While the wear simulator test in vitro demonstrated significant decrease in PE particles in the knees with an OxZr femoral component, our study in vivo revealed that total particle weight, size, and shape of PE wear particles were similar in the knees with an OxZr femoral component and in those with a Co-Cr femoral component.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 443 - 443
1 Nov 2011
Lee K Lee K Kim I Oh Y Park J Nam S Shim Y Jang J
Full Access

This study aims to identify the efficiency of biomechanical and bioactive properties of the bovine cortical bone cage treated with conditionally surface demineralization.

The procured bovine femoral bones were got rid of lipid, protein, and blood materials by chemical process such as 3% hydrogen peroxide and 70% ethanol.

The long shaft bones were cut by band saw. Several bone cages were processed by milling machine. The cortical bone cages were demineralized by 0.6N HCl treatment with various conditions, which were the tendency of HCl treatment time, position, direction. After neutralization with pH 7.0, phosphate buffered saline washing and freeze drying process, the vial vacuum packed bone cages were sterilized by 25kGy gamma irradiation. The SEM and EDS system were proceeded for morphology and Ca content in various layers of bone cage. In vitro test for cell viability and differentiation, extracted supernatant from each bone cage by tissue culture was treated in MC3T3E1 cells. For indentifying releasing materials, the others were carried for quantitative analysis by ELISA. After each conditioned period, mRNA expression was compared by RT-PCR. The axial compression and bending strength were measured by universal testing machine (UTM) for biomechanical property.

Between the outer layer and inner layer of bone cage for 2 hour’s HCl, there was concentrated Ca extracted layer. The tendency of Ca content and direction of demineralised treatment had effects on the compression and elastic strength. In vitro test, initial Osteogenic transcription factor’s mRNA expression and quantitative result of releasing material had rewarding regulation by HCl-treatment time and treated direction. Conditionally surface demineralized bone cage had good osteoconduc-tivity and osteoinductivity for spinal interbody fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 634 - 638
1 May 2011
Cho T Kim J Lee JW Lee K Park MS Yoo WJ Chung CY Choi IH

We investigated the fracture-free survival of long bones stabilised by a telescopic intramedullary rod (TIMR) in patients with osteogenesis imperfecta with respect to the remodelling status of fracture or osteotomy sites and TIMR regions, in order to identify risk factors for fracture. A total of 44 femora and 28 tibiae in 25 patients with a mean age of 5.0 years (1.9 to 10.5) at presentation were studied. There were six patients with Sillence type I, five with type III, 13 with type IV and one with type V osteogenesis imperfecta. All received bisphosphonate treatment at the same stage during the mean follow-up of 7.3 years (0.5 to 18.1). The fracture-free survival was estimated at 6.2 years (95% confidence interval 5.1 to 7.3) by Kaplan-Meier analysis. More than half the fracture or osteotomy sites remained in a less-remodelled state at the latest follow-up or time of fracture. Of the 33 fractures, 29 (87.9%) occurred in long bones containing a less-remodelled site, and these fractures were located at this site. The relative fracture risk at the rod tip was significantly greater than in any other TIMR region (p < 0.001), and this was higher in bone segments having a less-remodelled site.

This study shows a persistent fracture risk in TIMR-stabilised long bones, especially at less-remodelled fracture or osteotomy sites and at the rod tip.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 21 - 22
1 Jan 2011
Ng A Lee K To BS
Full Access

Gentamicin is one of the most widely used antibiotics in Orthopaedic practice. It is commonly used as prophylaxis either through intravenous route, incorporated into bone cement or topical intraoperative irrigation. The former two are well studied. However, there is limited study on the therapeutic efficacy and safety of topical Gentamicin irrigation.

To assess the safety and infection rate of joint replacement surgery when topical gentamicin irrigation was used. This is a non-randomised, prospective study whereby patients undergoing joint replacement surgery were treated with gentamicin irrigation intra-operatively.

A total of 138 patients were divided into two groups in this study. Group A (98 patients) were patients with Total Joint Replacement and group B (40 patients) were patients with hemi arthroplasty of the hips and shoulders. Patients with pre-existing renal impairment were excluded. Two ampoules of Gentamicin (160mg) were irrigated into the wound before implants insertion and wound closure respectively. Intravenous Cefuroxime was also given prophylactically to all patients but none of them had intravenous gentamicin. Plasma Gentamicin level was assayed 4 hours and 24 hours post-operatively.

There were 16 patients in group A (16%; p< 0.001) and 12 patients in group B (30%; p< 0.001)) found to have plasma Gentamicin level > 2mcg/ml. All but 6 had plasma gentamicin level dropped to < 2mcg/ml at 24 hours. Although none of them developed systemic complications, the raise in plasma gentamicin was alarming. The incidence of infection was 6.1% (6 patients) in group A. These were superficial wound infection responded to antibiotics. No infection was reported in group B.

This study did not show apparent reduction in infection rate as compared to the reported literatures. Nevertheless, there was significant systemic absorption of topical gentamicin irrigation. Therefore, monitoring of post-operative plasma gentamicin levels is mandatory to avoid unforseen toxicity.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1548 - 1552
1 Nov 2010
Song K Johnson JS Choi B Wang JC Lee K

We evaluated the efficacy of anterior fusion alone compared with combined anterior and posterior fusion for the treatment of degenerative cervical kyphosis. Anterior fusion alone was undertaken in 15 patients (group A) and combined anterior and posterior fusion was carried out in a further 15 (group B). The degree and maintenance of the angle of correction, the incidence of graft subsidence, degeneration at adjacent levels and the rate of fusion were assessed radiologically and clinically and the rate of complications recorded. The mean angle of correction in group B was significantly higher than in group A (p = 0.0009). The mean visual analogue scale and the neck disability index in group B was better than in group A (p = 0.043, 0.0006). The mean operation time and the blood loss in B were greater than in group A (p < 0.0001, 0.037). Pseudarthrosis, subsidence of the cage, and problems related to the hardware were more prevalent in group A than in group B (p = 0.034, 0.025, 0.013).

Although the combined procedure resulted in a longer operating time and greater blood loss than with anterior fusion alone, our results suggest that for the treatment of degenerative cervical kyphosis the combined approach leads to better maintenance of sagittal alignment, a higher rate of fusion, a lower incidence of complications and a better clinical outcome.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 400 - 400
1 Jul 2010
Ng A Lee K Se To B
Full Access

Introduction: Gentamicin is one of the most commonly used antibiotics in orthopaedic practice. It is mostly used as prophylaxis either through intravenous route, incorporated into bone cement or as local irrigation intra-operatively. The former two have been well studied. However, the literature on the therapeutic efficacy and safety of gentamicin irrigation is sparse. The objective of this study is to assess the safety of gentamicin irrigation in joint replacement surgery and associated infection rate.

Methods: This is a non-randomized, prospective study whereby patients undergoing joint replacement surgery were treated with gentamicin irrigation intra-operatively. Patients with pre-existing renal impairment were excluded. Two ampoules of Gentamicin (160mg) were irrigated into the wound before implants insertion and wound closure respectively. Cefuroxime was given pro-phylactically for all patients but none of them had intravenous gentamicin. Gentamicin level in the blood was assayed at 4 hours and 24 hours post-operation.

Results: A total of 138 patients were divided into two groups in this study. Group A (98 patients) consisted of patients with Total Joint Replacement and group B (40 patients) consisted of patients with hemi- arthroplasty of the hips and shoulders. There were 16 patients in group A (16%) and 12 patients in group B (30%) found to have plasma gentamicin level above 2mcg/ml. All but 6 of them had their gentamicin level dropped to below 2mcg/ml after 24 hours. The incidence of superficial wound infection was 6.1% (6 patients) in group A. No infection was reported for group B.

Discussion: Although none of them developed systemic complications, the plasma gentamicin level is high enough to raise an alarm. In this study, there was no apparent reduction in infection rate as compared to literatures reported. However, there was significant systemic blood gentamicin absorption.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 92 - 92
1 Mar 2010
Lee K Lee K Jung H Shim Y Jang J
Full Access

Demineralized Bone Matrix (DBM) is currently used in various types of orthopaedic applications because of osteoconductive and osteoinductive properties. Fibrin glue is also used in cardiovascular and thoracic surgery due to its hemostatic, chemotactic and mitogenic properties. There is some possibility of being good biomaterial and biodegradable scaffold with DBM-fibrin glue mixture for bone void filler. After total hip replacement surgery, it takes long time to complete bone fusion. If patients have excess weight load after surgery, the artificial joint may not be adhered with patients’s bone.

That is why surgeons have to use any effective treatments for bone fusion for patient’s safety. In order to adapt to these surgical sites, DBMs are shaped in blocks or granules and preferable in porous forms. Combining these DBMs with fibrin glue provides a moldable and self-hardening composite biomaterial. This material will be applied to total hip replacement surgery for the effective fusion between bone and artificial joint. The aim of this work is to study the osteogenic properties of this composite material using in vivo and ex vivo. In radiological study, the DBM composite had been absorbed during one week since implantation surgery and after two weeks, some radio-opaque spots were observed in implantation sites. In histology study, Bone tissue had formed exotically in contact with the surface of the appeared well-mineralized, forming trabeculae between the granules, and had characteristics similar to those of cancellous bone. Bone growth in the tissue engineered filled with DBM and fibrin glue materials increased with implantation time.

In summary, these DBM and fibrin glue composites exhibited interesting biological and mechanical properties for filling large bone defect. These composites may be used in total hip replacement surgery for the effective filler between patient’s bone and artificial joint.


Full Access

To date nine cases treated by cementless total ankle arthroplasty for avascular necrosis of the talar body have been described in the English literature. However, these reports show high complication rates including collapse of the talar component, and as a result cementless total ankle replacement is not recommended for the treatment of avascular necrosis of the talar body. The authors report two cases of ankle osteoarthritis with avascular necrosis of the talar body that were treated by cementless mobile bearing total ankle arthroplasty, because preoperative magnetic resonance images and radionuclide bone scanning showed revascularization of the talus. Recent follow-up plain radiographs of ankles showed no loosening or subsidence. The authors conclude that cementless total ankle arthroplasty for the treatment of avascular necrosis of the talar body is likely to be successful if necrotic bone has healed by creeping substitution and has enough strength to support an implant.