header advert
Results 1 - 20 of 21
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 71 - 71
11 Apr 2023
Pelegrinelli A Kowalski E Ryan N Dervin G Moura F Lamontagne M
Full Access

The study compared thigh-shank and shank-foot coordination during gait before and after total knee arthroplasty (TKA) with controls (CTRL).

Twenty-seven patients (male=15/female=12; age=63.2±6.9 years) were evaluated one month prior to and twelve months after surgery, and compared to 27 controls (male=14/female=13; age=62.2±4.3). The participants were outfitted with a full-body marker set. Gait speed (normalized by leg length) was calculated. The time series of the thigh, shank, and foot orientation in relation to the laboratory coordinate system were extracted. The coordination between the thigh-shank and shank-foot in the sagittal plane were calculated using a vector coding technique. The coupling angles were categorized into four coordination patterns. The stance phase was divided into thirds: early, mid, and late stance. The frequency of each pattern and gait speed were compared using a one-way ANOVA with a post-hoc Bonferroni correction.

Walking speed and shank-foot coordination showed no differences between the groups. The thigh-shank showed differences. The pre-TKA group showed a more in-phase pattern compared to the CTRL group during early-stance. During mid-stance, the pre- and post-TKA presented a more in-phase pattern compared to the CTRL group. Regarding shank-foot coordination, the groups presented an in-phase and shank pattern, with more shank phase during mid-stance and more in-phase during late-stance.

The pre-TKA group showed greater differences than the post-TKA compared to the controls. The more in-phase pattern in the pre- and post-TKA groups could relate to a reduced capacity for the thigh that leads the movement. During mid-stance in normal gait, the knee is extending, where the thigh and shank movements are in opposite directions. The in-phase results in the TKA groups indicate knee stiffness during the stance phase, which may relate to a muscular deficit or a gait strategy to reduce joint stress.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 26 - 26
11 Apr 2023
Kowalski E Pelegrinelli A Ryan N Dervin G Lamontagne M
Full Access

This study examined pre-operative measures to predict post-operative biomechanical outcomes in total knee arthroplasty (TKA) patients.

Twenty-eight patients (female=12/male=16, age=63.6±6.9, BMI=29.9±7.4 kg/m2) with knee osteoarthritis scheduled to undergo TKA were included. All surgeries were performed by the same surgeon (GD) with a subvastus approach. Patients visited the gait lab within one-month prior to surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), maximum knee flexion and extension strength evaluation, and a walking task. Variables of interest included the five KOOS sub-scores, TUG time, maximum knee flexion and extension strength normalized to body weight, walking speed, and peak knee biomechanics variables (flexion angle, abduction moment, power absorption). A Pearson's correlation was used to identify significantly correlated variables which were then inputted into a multiple regression.

No assumption violations for the multiple regression existed for any variables. Pre-operative knee flexion and extension strength, TUG time, and age were used in the multiple regression. The multiple regression model statistically significantly predicted peak knee abduction moment, post-operative walking speed, and post-operative knee flexion strength. All four variables added statistically significantly to the prediction p<.05.

Pre-operative KOOS values did not correlate with any biomechanical indicators of post-operative success. Age, pre-operative knee flexion and extension strength, and TUG times predicted peak knee abduction moment, which is associated with medial knee joint loading. These findings stress the importance of pre-surgery condition, as stronger individuals achieved better post-operative biomechanical outcomes. Additionally, younger patients had better outcomes, suggesting that surgeons should not delay surgery in younger patients. This delay in surgery may prevent patients from achieving optimal outcomes. Future studies should utilize a hierarchical multiple regression to identify which variables are most predictive.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 17 - 17
1 Dec 2022
Kowalski E Dervin G Lamontagne M
Full Access

One in five patients remain unsatisfied due to ongoing pain and impaired mobility following total knee arthroplasty (TKA). It is important if surgeons can pre-operatively identify which patients may be at risk for poor outcomes after TKA. The purpose of this study was to determine if there is an association between pre-operative measures and post-operative outcomes in patients who underwent TKA.

This study included 28 patients (female = 12 / male = 16, age = 63.6 ± 6.9, BMI = 29.9 ± 7.4 kg/m2) with knee osteoarthritis who were scheduled to undergo TKA. All surgeries were performed by the same surgeon (GD), and a subvastus approach was performed for all patients. Patients visited the gait lab within one-month of surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), and walking task. Variables of interest included the five KOOS sub-scores (symptoms, pain, activities of daily living, sport & recreation, and quality of life), completion time for the TUG, walking speed, and peak knee biomechanics variables (flexion angle, abduction moment, power absorption). A Pearson's product-moment correlation was run to assess the relationship between pre-operative measures and post-operative outcomes in the TKA patients.

Preliminary analyses showed the relationship to be linear with all variables normally distributed, as assessed by Shapiro-Wilk's test (p > .05), and there were no outliers. There were no statistically significant correlations between any of the pre-operative KOOS sub-scores and any of the post-operative biomechanical outcomes. Pre-operative TUG time had a statistically significant, moderate positive correlation with post-operative peak knee abduction moments [r(14) = .597, p < .001] and peak knee power absorption [r(14) = .498, p = .007], with pre-operative TUG time explaining 36% of the variability in peak knee abduction moment and 25% of the variability in peak knee power absorption. Pre-operative walking speed had a statistically significant, moderate negative correlation with post-operative peak knee abduction moments [r(14) = -.558, p = .002] and peak knee power absorption [r(14) = -.548, p = .003], with pre-operative walking speed explaining 31% of the variability in peak knee abduction moment and 30% of the variability in peak knee power absorption.

Patient reported outcome measures (PROMs), such as the KOOS, do indicate the TKA is generally successful at relieving pain and show an overall improvement. However, their pre-operative values do not correlate with any biomechanical indicators of post-operative success, such as peak knee abduction moment and knee power. Shorter pre-operative TUG times and faster pre-operative walking speeds were correlated with improved post-operative biomechanical outcomes. These are simple tasks surgeons can implement into their clinics to evaluate their patients. Future research should expand these findings to a larger sample size and to determine if other factors, such as surgical approach or implant design, improves patient outcomes.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 90 - 90
1 Nov 2021
Kowalski E Catelli D Lamontagne M Dervin G
Full Access

Introduction and Objective

Gait variability is the amplitude of the fluctuations in the time series with respect to the mean of kinematic (e.g., joint angles) or kinetic (e.g., joint moments) measurements. Although gait variability increases with normal ageing or pathological mechanisms, such as knee osteoarthritis (OA). The purpose was to determine if a patient who underwent a total knee arthroplasty (TKA) can reduce gait variability.

Materials and Methods

Twenty-five patients awaiting TKA were randomly assigned to receive either medial pivot (MP, m=7/f=6, age=62.4±6.2 years) or posterior stabilized (PS, m=7/f=5, age=63.7±8.9 years) implants, and were compared to 13 controls (CTRL, m=7/f=6, age=63.9±4.3 years). All patients completed a gait analysis within one month prior and 12 months following surgery, CTRLs completed the protocol once. A waveform F-Test Method (WFM) was used to compare the variance in knee biomechanics variables at each interval of the gait cycle.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 47 - 47
1 Feb 2021
Catelli D Grammatopoulos G Cotter B Mazuchi F Beaule P Lamontagne M
Full Access

Introduction

Interactions between hip, pelvis and spine, as abnormal spinopelvic movements, have been associated with inferior outcomes following total hip arthroplasty (THA). Changes in pelvis position lead to a mutual change in functional cup orientation, with both pelvic tilt and rotation having a significant effect on version. Hip osteoarthritis (OA) patients have shown reduced hip kinematics which may place increased demands on the pelvis and the spine.

Sagittal and coronal planes assessments are commonly done as these can be adequately studied with anteroposterior and lateral radiographs. However, abnormal pelvis rotation is likely to compromise the outcome as they have a detrimental effect on cup orientation and increased impingement risk. This study aims to determine the association between dynamic motion and radiographic sagittal assessments; and examine the association between axial and sagittal spinal and pelvic kinematics between hip OA patients and healthy controls (CTRL).

Methods

This is a prospective study, IRB approved. Twenty hip OA pre-THA patients (11F/9M, 67±9 years) and six CTRL (3F/3M, 46±18 years) underwent lateral spinopelvic radiographs in standing and seated bend-and-reach (SBR) positions. Pelvic tilt (PT), pelvic-femoral-angle (PFA) and lumbar lordosis (LL) angles were measured in both positions and the differences (Δ) between standing and SBR were calculated. Dynamic SBR and seated maximal-trunk-rotation (STR) were recorded in the biomechanics laboratory using a 10-infrared camera and processed on a motion capture system (Vicon, UK). Direct kinematics extracted maximal pelvic tilt (PTmax), hip flexion (HFmax) and (mid-thoracic to lumbar) spinal flexion (SFmax). The SBR pelvic movement contribution (ΔPTrel) was calculated as ΔPT/(ΔPT+ΔPFA)∗100 for the radiographic analysis and as PTmax/(PTmax+HFmax) for the motion analyses. Axial and sagittal, pelvic and spinal range of motion (ROM) were calculated for STR and SBR, respectively. Spearman's rank-order determined correlations between the spinopelvic radiographs and sagittal kinematics, and the sagittal/axial kinematics. Mann-Whitney U-tests compared measures between groups.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 12 - 12
1 Oct 2020
Lamontagne M Catelli DS Cotter B Mazuchi FAS Grammatopoulos G
Full Access

Introduction

Spinopelvic mobility has been associated with THA outcome. To-date spine assessments have been made quasi-statically, using radiographs, in standing and seated positions but dynamic spinopelvic mobility has not been well explored. This study aims to determine the association between dynamic (motion analysis) and quasi-static (radiographic) sagittal assessments and examine the association between axial and sagittal spinal kinematics in hip OA patients and controls.

Methods

This is a prospective, IRB approved, cohort study of 12 patients with hip OA pre-THA (6F/6M, 67±10 years) and six healthy controls (3F/3M, 46±18 years). All underwent lateral spinopelvic radiographs in standing and seated bend-and-reach (SBR) positions. Pelvic tilt (PT), pelvic-femoral-angle (PFA) and lumbar lordosis (LL) angles were measured in both positions and the differences (Δ) in angles between SBR and standing were computed. All participants performed two dynamic tasks at the motion laboratory: seated maximal trunk rotation (STR) and seated bend and reach (SBR). Three-dimensional joint motion data were collected and processed by a 10-camera infrared motion analysis system (Vicon, Nexus 2.10, UK). Total axial and sagittal spine (mid-thoracic to lumbar) range of motion (ROM) were calculated for STR and SBR, respectively.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 109 - 109
1 Jul 2020
Kowalski E Lamontagne M Catelli D Beaulé P
Full Access

The literature indicates that femoroacetabular impingement (FAI) patients do not return to the level of controls (CTRL) following surgery. The purpose of this study was to compare hip biomechanics during stair climbing tasks in FAI patients before and two years after undergoing corrective surgery against healthy controls (CTRL).

A total of 27 participants were included in this study. All participants underwent CT imaging at the local hospital, followed by three-dimensional motion analysis done at the human motion biomechanics laboratory at the local university. Participants who presented a cam deformity >50.5° in the oblique-axial or >60° in the radial planes, respectively, and who had a positive impingement test were placed in the FAI group (n=11, age=34.1±7.4 years, BMI=25.4±2.7 kg/m2). The remaining participants had no cam deformity and negative impingement test and were placed in the CTRL group (n=16, age=33.2±6.4 years, BMI=26.3±3.2 kg/m2). The CTRL group completed the biomechanics protocol once, whereas the FAI group completed the protocol twice, once prior to undergoing corrective surgery for the cam FAI, and the second time at approximately two years following surgery.

At the human motion biomechanics laboratory, participants were outfitted with 45 retroreflective markers placed according to the UOMAM marker set. Participants completed five trials of stairs task on a three step instrumented stair case to measure ground reaction forces while 10 Vicon MX-13 cameras recorded the marker trajectories. Data was processed using Nexus software and divided into stair ascent and stair descent tasks. The trials were imported into custom written MatLab software to extract peak pelvis and hip kinematics and hip kinetic variables. Non-parametric Kruskal-Wallis tests were used to determine significant (p < 0.05) differences between the groups.

No significant differences occurred during the stair descent task between any of the groups. During the stair ascent task, the CTRL group had significantly greater peak hip flexion angle (Pre-Op=58±7.1°, Post-Op=58.1±6.6°, CTRL=64.1±5.1°) and sagittal hip range of motion (ROM) (Pre-Op=56.7±6.7°, Post-Op=56.3±5.5°, CTRL=61.7±4.2°) than both the pre- and post-operative groups. Pre-operatively, the FAI group had significantly less peak hip adduction angle (Pre-Op=2±4.5°, Post-Op=3.4±4.4°, CTRL=5.5±3.7°) and hip frontal ROM (Pre-Op=9.9±3.4°, Post-Op=11.9±5.4°, CTRL=13.4±2.5°) compared to the CTRL group. No significant differences occurred in the kinetic variables.

Our findings are in line with the Rylander and colleagues (2013) who also found that hip sagittal ROM did not improve following corrective surgery. Their study included a mix of cam and pincer-type FAI, and had a mean follow-up of approximately one year. Our cohort included only cam FAI and they had a mean follow-up of approximately two years, indicating with the extra year, the patients still did not show sagittal hip kinematics improvement. In the frontal plane, there was no significant difference between the post-op and the CTRL, indicating that the postoperative FAI reached the level of the CTRLs. This is in line with recent work that indicates a more medialized hip contact force vector following surgery, suggesting better hip stabilization.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 54 - 54
1 Oct 2019
Lamontagne M Catelli DS Beaulé PE
Full Access

Osteochondroplasty procedure for cam deformity provides excellent outcomes on alleviating pain, improving quality of life and clinical function in femoroacetabular impingement syndrome (FAIS) patients. Although medium-term outcomes on gait biomechanics have been reported, it is unclear how it would translate to better hip muscle forces and joint loading in high range of motion tasks. The purpose of this study was to compare the muscle forces and hip joint contact forces (HCF) during a squat task in individuals before and after cam-FAIS surgical correction. Ten cam-FAIS patients prior and 2-years after osteochondroplasty, and 10 BMI- age- and sex-matched healthy control participants (CTRL) underwent 3D motion and ground reaction forces capture while performing a deep squatting task. Muscle and HCF were estimated using musculoskeletal modeling and comparisons were done using statistical parametric mapping (SPM).

Postoperatives squatted down with a higher anterior pelvic tilt and higher hip flexion compared with the preoperatives. Preoperative semimembranosus generated lower forces than the two other groups on the squat ascending, with no differences detected between post-ops and CTRLs. Preoperatives also showed reduced forces for the distal, ischial and medial portions of the adductor magnus relative to the CTRLs, which although reduced, still presented differences postoperatively. Preoperative anterior and medial contact forces were significantly lower than the CTRL group during both phases of the squat. Postoperative vertical and medial forces were also lower compared to the CTRLs. However, with higher vertical forces during the ascent phase of the squat compared to the preoperative, the postoperative group, significantly increased its HCF magnitude. A higher anterior pelvic tilt was associated with an innate restoration of the pelvis position, once the cam deformity no longer existed. The increased force of the semimembranosus muscle while ascending the squat generated higher vertical HCF, which also influenced the increased HCF total magnitude.

For any tables or figures, please contact the authors directly.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 59 - 59
1 Apr 2019
Lamontagne M Kowalski E Galmiche R Dervin G
Full Access

Many patients who undergo a total knee arthroplasty (TKA) wish to return to a more active lifestyle. The implant must be able to restore adequate muscle strength and function. However, this may not be a reality for some patients as quadriceps and hamstrings muscle activity may remain impaired following surgery.

The purpose of this study was to compare muscle activity between patients implanted with a medial pivot (MP) or posterior stabilized (PS) implant and controls (CTRL) during ramp walking tasks.

Fifteen patients were assigned to either a MP (n=9) or PS (n=6) TKA operated by the same surgeon. Nine months following surgery, the 15 patients along with nine CTRL patients completed motion and EMG analysis during level, ramp ascent & descent walking tasks.

Wireless EMG electrodes were placed on six muscles: vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), semimembranosus (SM) muscles, gastrocnemius medial head (GM), and gastrocnemius lateral head (GL). Participants completed three trials of each condition.

EMG data were processed for an entire gait cycle of the operated limb in the TKA groups, and for the dominant limb in the CTRL group. The maximum muscle activity achieved with each muscle during the level trial was used to normalize the ramp trials. The onset and offset of each muscle was determined using the approximated generalized likelihood ratio.

Peak muscle activity (PeakLE), total muscle activity (iEMG), and muscle onsets/offsets were determined for each muscle for the ramp ascent and descent trials. Non-parametric Kruskal Wallace tests were used to test for statistical significance between groups with α=0.05.

During the ramp up task, both MP and PS groups had significantly greater PeakLE and iEMG for the hamstring muscles compared to the CTRL, whereas the PS group had significantly greater PeakLE compared with the MP group for the SM muscle.

During the ramp down task, both MP and PS groups had significantly greater PeakLE and iEMG for the SM and GL muscles compared to the CTRL. The PS group also had significantly greater iEMG for the BF and VM muscles compared to the CTRL. The MP group had a significantly earlier offset for the SM muscle compared to the CTRL.

Stability in a cruciate removing TKA is partially controlled by the prosthetic design. During the ramp up task, the TKA groups compensated the tibial anterior translation by activating their hamstrings more and for a longer duration. The MP group required less hamstrings activation than the PS group.

During the ramp down task, TKA patients stiffened their knee in order to stabilize the joint. The quadriceps, hamstrings and GL muscle were activated more and for a longer duration than the CTRL group to protect the tibial posterior translation. The PS group required greater BF and VM iEMG than the MP group.

Even if surgery reduced pain, differences in muscle activity exist between TKA patients and healthy controls. The prosthetic design provides some stability to the knee, and the MP implant required less muscle activation than the PS implant to stabilize the knee joint.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 117 - 117
1 Nov 2018
Catelli D Ng K Kowalski E Beaulé P Lamontagne M
Full Access

Cam-type femoroacetabular impingement (FAI) is a common cause for athletic hip injury and early hip osteoarthritis. Although corrective cam FAI surgery can improve patient reported outcome measures (PROMs), it is not clear how surgery affects muscle forces and hip joint loading. Surgery for FAI may redistribute muscle forces and contact forces at the hip joint during routine activities. The purpose of this study was to examine the muscle contributions and hip contact forces during gait in patients prior and after two years of undergoing surgery for cam FAI. Kinematics and kinetics were recorded in 11 patients with symptomatic cam FAI as they completed a gait task. Muscle and hip contact forces during the stance phase were estimated using musculoskeletal modelling and static optimization in OpenSim. All patients reported improvements in PROMs. Post-operatively, patients showed reduced forces in the long head of the biceps femoris at ipsilateral foot-strike and in the rectus femoris at the contralateral foot-strike. The reduced muscle forces decreased sagittal hip moment but did not change hip contact forces. This was the first study to evaluate hip muscle and contact forces in FAI patients post-operatively. Although hip contact forces are not altered following surgery, muscle forces are decreased even after two years. These findings can provide guidance in optimizing recovery protocols after FAI surgery to improve hip flexor and extensor muscle forces.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 1 - 1
1 May 2018
Grammatopoulos G Speirs A Ng G Riviere C Rakhra K Lamontagne M Beaule PE
Full Access

Introduction

Acetabular and spino-pelvic (SP) morphological parameters are important determinants of hip joint dynamics. This study aims to determine whether acetabular and SP morphological differences exist between hips with and without cam morphology and between symptomatic and asymptomatic hips with cam morphology.

Patients/Materials & Methods

A prospective cohort of 67 patients/hips was studied. Hips were either asymptomatic with no cam (Controls, n=18), symptomatic with cam (n=26) or asymptomatic with cam (n=23). CT-based quantitative assessments of femoral, acetabular, pelvic and spino-pelvic parameters were performed. Measurements were compared between controls and those with a cam deformity, as well as between the 3 groups. Morphological parameters that were independent predictors of a symptomatic Cam were determined using a regression analysis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 99 - 99
1 Feb 2017
Lamontagne M Kowalski E Dervin G
Full Access

Introduction

Patients undergoing a total knee arthroplasty (TKA) are now living longer and partaking in more active lifestyles. They expect a high level of post-operative function and long term durability of their implant.

Using electromyography (EMG) analysis helps further explain biomechanical findings by giving insight as to what is occurring at the level of the muscles. Normal biomechanics are not restored post-TKA as patients have reduced knee flexion and weakened quadriceps muscles compared to their healthy peers.

Purpose

The purpose of this study was to compare muscle activation in TKA patients who received a medial pivot (MP) or posterior stabilized (PS) implant to those of healthy controls (CTRL) during a stair ascent task.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 4 - 4
1 Jan 2017
Lamontagne M Kowalski E Catelli D Beaulé P
Full Access

Dual mobility (DM) bearing implants reduce the incidence of dislocation following total hip arthroplasty (THA) and as such they are used for the treatment of hip instability in both primary and revision cases. The aim of this study was to compare lower limb muscle activity of patients who underwent a total hip arthroplasty (THA) with a dual mobility (DM) or a common cup (CC) bearing compared to healthy controls (CON) during a sit to stand task.

A total of 21 patients (12 DM, 9 CC) and 12 CON were recruited from the local Hospital. The patients who volunteered for the study were randomly assigned to either a DM or a CC cementless THA after receiving informed consent. All surgeries were performed by the same surgeon using the direct anterior approach. Participants underwent electromyography (EMG) and motion analysis while completing a sit-to-stand task. Portable wireless surface EMG probes were placed on the vastus lateralis, rectus femoris, biceps femoris, semitendinosus (ST), gluteus medius and tensor fasciae latae muscles of the affected limb in the surgical groups and the dominant limb in the CON group. Motion capture was used to record lower limb kinematics and kinetics. Muscle strength was recorded using a hand-held dynamometer during maximal voluntary isometric contraction (MVIC) testing. Peak linear envelope (peakLE) and total muscle activity (iEMG) were extrapolated and normalized to the MVIC and time cycle for the sit to stand task. Using iEMG, quadriceps-hamstrings muscle co-activation index was calculated for the task. Nonparametric Kruskal Wallace ANOVA tests and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred.

The DM group had greater iEMG of the ST muscle compared to the CC (p=0.045) and the CON (p=0.015) groups. The CC group had lower iEMG for hamstring muscles compared to the DM (p=0.041) group. The DM group showed lower quadriceps-hamstrings co-activation index compared to the CON group and it approached significance (p=0.054). The CC group had greater anterior pelvis tilt compared to both DM (p=0.043) and the CON (p=0.047) groups. The DM also had larger knee varus angles and less knee internal rotation compared to both groups, however this never reached significance. No significant differences in muscle strength existed between the groups.

Higher ST muscle activity in the DM group is explained by the reduction in internal rotation at the knee joint as the ST muscle was more active to resist the varus forces during the sit-to-stand task. Reduced quadriceps activity in the CC group is explained by increased pelvic anterior tilt as this would shorten the moment arm and muscle length in the quadriceps, ultimately reducing quadriceps muscle activity. The reduced co-activation between quadriceps and hamstrings activity in the DM group compared to the CC and CON groups is related to better hip function and stability. Combining lower co-activation and larger range of motion for the DM group without impingement, this implant seems to offer better prevention against THA subluxation and less wear of the implant.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 51 - 51
1 Nov 2016
Lamontagne M Ng G Catelli D Beaulé P
Full Access

With the growing number of individuals with asymptomatic cam-type deformities, elevated alpha angles alone do not always explain clinical signs of femoroacetabular impingement (FAI). Differences in additional anatomical parameters may affect hip joint mechanics, altering the pathomechanical process resulting in symptomatic FAI. The purpose was to examine the association between anatomical hip joint parameters and kinematics and kinetics variables, during level walking.

Fifty participants (m = 46, f = 4; age = 34 ± 7 years; BMI = 26 ± 4 kg/m²) underwent CT imaging and were diagnosed as either: symptomatic (15), if they showed a cam deformity and clinical signs; asymptomatic (19), if they showed a cam deformity, but no clinical signs; or control (16), if they showed no cam deformity and no clinical signs. Each participant's CT data was measured for: axial and radial alpha angles, femoral head-neck offset, femoral neck-shaft angle, medial proximal femoral angle, femoral torsion, acetabular version, and centre-edge angle. Participants performed level walking trials, which were recorded using a ten-camera motion capture system (Vicon MX-13, Oxford, UK) and two force plates (Bertec FP4060–08, Columbus, OH, USA). Peak sagittal and frontal hip joint angles, range of motion, and moments were calculated using a custom programming script (MATLAB R2015b, Natick, MA, USA). A one-way, between groups ANOVA examined differences among kinematics and kinetics variables (α = 0.05), using statistics software (IBM SPSS v.23, Armonk, NY, USA); while a stepwise multiple regression analysis examined associations between anatomical parameters and kinematics and kinetics variables.

No significant differences in kinematics were observed between groups. The symptomatic group demonstrated lower peak hip abduction moments (0.12 ± 0.08 Nm/kg) than the control group (0.22 ± 0.10 Nm/kg, p = 0.01). Sagittal hip range of motion showed a moderate, negative correlation with radial alpha angle (r = −0.33, p = 0.02), while peak hip abduction moment correlated with femoral neck-shaft angle (r = 0.36, p = 0.009) and negatively with femoral torsion (r = −0.36, p = 0.009). With peak hip abduction moment in the stepwise regression analysis, femoral torsion accounted for a variance of 13.3% (F(1, 48) = 7.38; p = 0.009), while together with femoral neck-shaft angle accounted for a total variance of 20.4% (R² change = 0.07, F(2, 47) = 6.01; p = 0.047).

Although elevated radial alpha angles may have limited sagittal range of motion, the cam deformity parameters did not affect joint moments. Femoral neck-shaft angle and femoral torsion were significantly associated with peak hip abduction moment, suggesting that the insertion location of the abductor affects muscle's length and its resultant force vector. A varus neck angle, combined with severe femoral torsion, may ultimately influence muscle moment arms and hip mechanics in individuals with cam FAI.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 3 - 3
1 Nov 2016
Lamontagne M Kowalski E Dervin G
Full Access

The purpose of this study was to compare lower limb joint mechanics in patients who underwent a total knee arthroplasty (TKA) with either a posterior stabilised (PS) or with a medial pivot (MP) implant to healthy controls (CTRL) during stair ascent and descent tasks.

Six PS (age: 67.2±1.5 years, BMI: 31.0±3.2 kg/m2) and 11 MP (age: 62.3±6.0 years, BMI: 29.7±3.9 kg/m2) TKA patients matched to 10 healthy CTRL participants (age: 65.6±5.5 years, BMI: 27.2±5.0 kg/m2) were included in the study. TKA patients went through 3D motion analysis after unilateral TKA with either a MP (11.7±3.4 months post-surgery) or PS (10.1±3.4 months post-surgery) implant performed using either a subvastus or medial parapatellar approach. Kinematic and kinetic data was collected using a 10-camera Vicon and two portable Kistler force plates placed on the first and second stair of a three-step staircase. Nonparametric Kruskal Wallace ANOVA tests were used and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred.

When comparing both stair tasks, stair ascent showed a larger number of significant differences in kinematic and kinetic variables than stair descent. Peak knee extension was significantly (p < 0.05) greater in both TKA groups compared to the CTRL during stair descent, whereas only the PS group had significantly (p = 0.02) greater knee extension angle than the CTRL during stair ascent. The PS group had a significantly (p = 0.01) lower peak knee extension moment than the CTRL group during both tasks and compared to the MP group during stairs ascent. During stair ascent, the MP group had significantly (p = 0.02) larger peak hip extension moments than both PS and CTRL group.

Greater knee extension angles in TKA groups at foot strike during stair tasks support the notion that TKA groups exhibit stiff knee during stance to reduce or avoid shear displacement on the operated knee. This could also result from many years of muscle adaptation waiting to receive a knee replacement. Reduced peak knee extension moment in the PS group during stairs tasks showed a quadriceps deficiency that could increase the risk of revision or of other joint replacement on the contralateral side or ipsilateral hip. MP group reproduced similar joint loading patterns as the CTRLs which may reduce their risk of revision. In conclusion, TKA patients continue to exhibit discrepancies from healthy knee mechanics during stair ascent and descent. Further research examining muscle function especially during stair ascent is warranted.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 2 - 2
1 Nov 2016
Lamontagne M Kowalski E Dervin G
Full Access

The purpose of this study was to compare lower limb muscle activity in patients who underwent a total knee arthroplasty (TKA) with a medial pivot (MP) implant to healthy controls (CTRL) during a stair ascent task.

Seven MP (age: 61.4±6.5 years, BMI: 30.0±4.7 kg/m2, 12.4±3.8 months post-surgery) patients who underwent a TKA performed using either a subvastus or medial parapatellar approach were age- and BMI-matched to seven healthy CTRL participants (age: 62.4±4.2 years, BMI: 26.3±2.7 kg/m2) for comparison in this study. Participants underwent electromyography (EMG) analysis while completing a three-step stairs ascent task. Portable wireless surface EMG probes were placed on the vastus lateralis (VL), rectus femoris (RF), vastus medialis (VM), biceps femoris (BF) and semimembranous (SM) muscles of both lower limbs. Peak linear envelope (peakLE) and total muscle activity (iEMG) were extrapolated and normalised to a maximal voluntary contraction. Nonparametric Kruskal Wallace ANOVA tests were used and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred.

The operated limb had significantly lower iEMG in the VAL, RF and BF muscles, and significantly lower peakLE in the SM muscle compared to the non-operated limb. The operated-limb of the MP group had significantly lower iEMG in the VAL and BF muscles, and significantly lower peakLE in the VAL, RF and SM muscles compared to the CTRL group. The non-operated limb in the MP group had significantly larger peakLE and iEMG in the RF muscle compared to the CTRL group.

Differences in muscle activity between the operated and non-operated limbs in TKA patients with a MP implant demonstrates a compensatory strategy to reduce loading on the operated limb by relying on the non-operated limb. This same strategy has been reported in other studies investigating other functional tasks. This reliance on the non-operated limb resulted by having greater peakLE and iEMG in the RF muscle compared to the healthy CTRLs. These differences between limbs could also result from many years of muscle adaptation waiting to receive a knee replacement. In conclusion, TKA patients exhibit discrepancies in muscle activity compared to healthy knees and differences between operated and non-operated limbs. Post-surgery rehabilitation should rely on unilateral strength exercises of the quadriceps and hamstrings muscles to reduce discrepancies to allow for a more balanced muscle activity between limbs.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 181 - 181
1 Jul 2014
Speirs A Frei H Lamontagne M Beaule P
Full Access

Summary

The cartilage layer from cam-type femoroacetabular impingement deformities had lower stiffness and increased permeability compared to normal cartilage. This is consistent with osteoarthritis and supports the hypothesis of abnormal contact stresses.

Introduction

Femoroacetabular impingement (FAI) has recently been associated with osteoarthritic (OA) degeneration of the hip and may be responsible for up to 90% of adult idiopathic OA cases. FAI results from deformities in the hip joint which may lead to abnormal contact stresses and degeneration. The more common cam-type deformity consists of a convex anterior femoral head-neck junction which impinges the anterosuperior acetabular rim during flexion and internal rotation of the hip. Increased subchondral bone density has been reported in this region which may be a bone remodelling response to increased contact stress. The abnormal contact is expected to cause degeneration of the cartilage layer. The goal of this study was to assess the mechanical properties of cartilage retrieved from the cam deformity and to compare this with normal articular cartilage from the femoral head. It is hypothesised that the cartilage will have a lower elastic modulus and higher permeability than normal cartilage.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 343 - 343
1 Jul 2014
Speirs A Huang A Lamontagne M Beaule P
Full Access

Summary Statement

This study quantifies compositional differences in cartilage between CAM deformities of symptomatic FAI patients and normal cadaver controls. It shows a resemblance of CAM-FAI cartilage with those of osteoarthritic hips, objectively supporting previous hypothesis of abnormal contact stresses in CAM-FAI.

Introduction

Degeneration of cartilage within articular joints is a pathological feature of osteoarthritis (OA). Femoroacetabular impingement (FAI), a condition of abnormal contact between the articular surfaces of the femur and acetabulum, has been widely associated with early onset OA of the hip. The purpose of this study was to quantitatively compare the proteoglycan (PG) content of the weight-bearing cartilage in surgical FAI patients versus those of cadavers without FAI.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 560 - 560
1 Nov 2011
Varin D Speirs A Benoit D Beaulieu M Lamontagne M Beaulé PE
Full Access

Purpose: A functional centre of rotation (CoR) is often required in biomechanical analysis of the hip or as a landmark in computer guided surgery. It was previously shown that circumduction motions predict a CoR that is inferior and lateral to the geometric centre of the hip bearing surfaces. It is therefore necessary to establish the best method for determining the CoR to improve surgical planning. The objective of this study was to compare the predicted CoR from circumduction and star motions, and to compare these to the geometric centre of the joint.

Method: Eight cadaveric hips from four cadavers were tested. Prior to testing, CT scans of the cadavers were made from the iliac crest to the tibial plateau; the alpha angle for all hips was less than 50° so all hips were considered ‘normal’. Reflective marker arrays were rigidly mounted on the femoral diaphysis and iliac spine using 4mm Steinman pins. A five-camera Vicon system (Oxford, UK) was used to track the motions of the arrays during manipulation of the lower limb. To determine the functional hip centre, trials consisting of five cycles each of circumduction, flexion-extension and abduction-adduction were performed on each lower limb; three trials of each motion were performed. The range of motion was approximately 45° in the coronal and sagittal planes. For the ‘star’ motion, the flexion-extension and abduction-adduction trial data were combined. Following the trials the hip was dissected to expose the articular surfaces of the femoral head and acetabulum. These surfaces were traced using a pointer equipped with reflective markers to determine the geometric centre. To calculate the functional centre, the 3D coordinates of the markers were used to construct a local-to-global 3D transform for each frame throughout the trial. The geometric centre was calculated using a least-squares sphere fit (Gauss-Newton) of the trace data, calculated in the respective local coordinate systems. The coordinates of the functional centres were then transformed to an anatomic coordinate system, using the geometric centre as the origin. All calculations were performed using Matlab (Mathworks, Inc, MA, USA). A t-test was performed in each anatomic direction to detect differences in CoR predicted by the two motions.

Results: Both the circumduction and star motions resulted in a similar CoR. Differences were 0.41±2.25mm in the anterior-posterior direction; 0.09±0.72mm in the superior-inferior direction; and 0.21±0.82mm in the medial-lateral direction, none of which were significant (p> 0.5). The overall mean distance between the CoR predicted by the two motions was 2.0±1.3mm. The functional centre was also found to be lateral and inferior to the geometric centre, and was consistent for each motion. Results for the acetabulum showed similar trends.

Conclusion: This study has shown that circumduction and star motions are equivalent in predicting the hip functional CoR; differences were small compared to the dimensions involved in studies such as gait analyses. However, both motions predicted a CoR that was inferior and lateral to the spherical centre of the femoral head, suggesting that the hip does not act as a true ball-and-socket joint with congruent spherical bearing surfaces. This may have important consequences in studies at the scale of the hip joint, especially for pathological conditions such as femoroacetabular impingement.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 554 - 554
1 Nov 2011
Ng KG Rouhi G Lamontagne M Beaulé PE
Full Access

Purpose: Femoroacetabular impingement (FAI) is recognized as a pathomechanical process that leads to hip osteoarthritis (OA). Past research has been focused on treatments for FAI; however, few studies have been done to link FAI with the progression of OA. It is hypothesized that elevated mechanical stimuli could provoke bone remodeling in the subchondral bone and articulating surfaces due to cam FAI (aspherical head-neck deformity), which would accelerate the progression of OA. Using finite element analysis (FEA), the aim is to compare healthy hips to hips with cam FAI – investigating the mechanical stimuli effect of FAI towards OA.

Method: Net joint reaction forces were obtained from joint kinematics, kinetics, and by inverse dynamics calculation for a dynamic squat motion of a control subject and a cam FAI patient (both males with comparable age, BMI, and femur lengths). CT scans were acquired from both subjects. Data slices were compiled using 3D-DOCTOR (Able Software Corp, MA) to form a 3D model with slice thickness calibrated at 1.25mm in the superior-inferior axis. ANSYS (ANSYS, PA) software was used for FEA. The femur models were given quadrilateral shell elements and modeled as linear elastic orthotropic materials. The ground reaction forces were applied to the femur models, simulating dynamic loads, using boundary conditions specific to hip loading. Von Mises stresses were determined to examine stress concentrations and adverse loading conditions. Strain energy distributions were determined to examine the effect of stimuli on the initiation and rate of bone remodeling.

Results: At the maximum squat-depth, the FEA results demonstrated that the net forces acting on the FAI hip produced high mechanical stimuli regions around the head and neck. The highest stress concentration (590 MPa) was located at the anterosuperior head-neck junction, where cam FAI is most prominent. For the control hip, stresses were significantly lower (maximum of 151 MPa) and dissipated around the head. For both the FAI and the control hip, the maximum strain energy concentrations were seen at the superior portion of the head (4.725 kJ vs. 2.192 kJ for FAI vs. control hip respectively).

Conclusion: The increase in mechanical stimuli can be due to the loading configurations as well as to the abnormal geometry of the cam deformity. Assuming that the strain energy density (SED) and its rate is linearly proportional to the rate of bone turnover, based on a recent semi-mechanistic bone remodeling theory, a higher rate of bone turnover is expected in the FAI than in a normal hip. Depending on the level and rate of SED, the rate of bone remodeling will vary in order to provide a new homeostatic configuration. The next-step analysis, examining the mechanical stimuli in the acetabulum and its cartilage, is currently in progress. This would provide useful information about the possible locations of OA initiation and establish a link between FAI with cartilage degeneration.