header advert
Results 1 - 20 of 26
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 7 - 7
23 Apr 2024
Williamson T Egglestone A Jamal B
Full Access

Introduction

Open fractures of the tibia are disabling injuries with a significant risk of deep infection. Treatment involves early antibiotic administration, early and aggressive surgical debridement, and may require complex soft tissue coverage techniques. The extent of disruption to the skin and soft-tissue envelope often varies, with ‘simple’ open fractures (defined by the Orthopaedic Trauma Society (OTS) open fracture severity classification) able to be closed primarily, whilst others may require shortening or soft-tissue reconstruction. This study aimed to determine whether OTS simple tibial open fractures received different rates of adequate debridement and plastic surgical presence at initial debridement, compared with OTS complex injuries, and whether rates of fracture-related infection, nonunion, or reoperation differed between the groups.

Materials & Methods

A consecutive series of open tibia fractures managed at a tertiary UK Major Trauma Centre between January 2021 and November 2022 were included. Patient demographics, injury characteristics, timing of antibiotic delivery, timing and method of definitive fixation, and frequency of plastic surgical presence at initial debridement were retrospectively collected. The delivery of bone ends at initial debridement was used as a proxy for adequacy of surgical debridement. The primary outcome measure was rate of fracture-related infection, secondary outcomes included rates of reoperation, nonunion, and amputation. Chi2 Tests and independent samples T-tests were used to assess nominal and continuous outcomes respectively between simple and complex injuries. Ordinal data was assessed using nonparametric equivalent tests.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 16 - 16
23 Apr 2024
Murray E Connaghan J Creavin K Egglestone A Jamal B
Full Access

Introduction

By utilising the inherent variability achievable with circular frames, surgeons can manage a wide spectrum of complex injuries, and can deal with deformity at multiple levels, in multiple planes. The aim of this study was to assess functional outcomes utilising patients reported outcome measures (PROMs) of patients being treated with circular (Ilizarov) frame fixation for complex lower limb injuries and assess these results in conjunction with the observed postoperative alignment of the patients’ limbs.

Materials & Methods

Cases were identified using a prospectively collected database of adult patients presenting between July 2018 and August 2021. Functional outcomes were assessed using the American Orthopaedic Foot and Ankle Score (AOFAS), the 5-level EQ-5D (EQ5D5L), the Lysholm Knee Scoring Scale (LKSS), the Olerud-Molendar Ankle Score (OMAS), and the Tegner Activity Scale (TAS). Postoperative radiographs were analysed for fracture union and to quantify malunion (as described in Dror Paleys Principles of Deformity Correction).


Bone & Joint 360
Vol. 13, Issue 1 | Pages 7 - 8
1 Feb 2024
Jamal B Round J Qureshi A


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 10 - 10
1 Jun 2023
Hrycaiczuk A Oochit K Imran A Murray E Brown M Jamal B
Full Access

Introduction

Ankle fractures in the elderly have been increasing with an ageing but active population and bring with them specific challenges. Medical co-morbidities, a poor soft tissue envelope and a requirement for early mobilisation to prevent morbidity and mortality, all create potential pitfalls to successful treatment. As a result, different techniques have been employed to try and improve outcomes. Total contact casting, both standard and enhanced open reduction internal fixation, external fixation and most recently tibiotalocalcaneal (TTC) nailing have all been proposed as suitable treatment modalities. Over the past five years popular literature has begun to herald TTC nailing as an appropriate and contemporary solution to the complex problem of high-risk ankle fragility fractures. We sought to assess whether, within our patient cohort, the outcomes seen supported the statement that TTC has equal outcomes to more traditional open reduction internal fixation (ORIF) when used to treat the high-risk ankle fragility fracture.

Materials & Methods

Results of ORIF versus TTC nailing without joint preparation for treatment of fragility ankle fractures were evaluated via retrospective cohort study of 64 patients with high-risk fragility ankle fractures without our trauma centre. We aimed to assess whether results within our unit were equal to those seen within other published studies. Patients were matched 1:1 based on gender, age, Charlson Comorbidity Index (CCI) and ASA score. Patient demographics, AO/OTA fracture classification, intra-operative and post-operative complications, discharge destination, union rates, FADI scores and patient mobility were recorded.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 38 - 38
1 Jun 2023
Hrycaiczuk A Biddlestone J Rooney B Mahendra A Fairbairn N Jamal B
Full Access

Introduction

A significant burden of disease exists with respect to critical sized bone defects; outcomes are unpredictable and often poor. There is no absolute agreement on what constitutes a “critically-sized” bone defect however it is widely considered as one that would not heal spontaneously despite surgical stabilisation, thus requiring re-operation. The aetiology of such defects is varied. High-energy trauma with soft tissue loss and periosteal stripping, bone infection and tumour resection all require extensive debridement and the critical-sized defects generated require careful consideration and strategic management. Current management practice of these defects lacks consensus. Existing literature tells us that tibial defects 25mm or great have a poor natural history; however, there is no universally agreed management strategy and there remains a significant evidence gap. Drawing its origins from musculoskeletal oncology, the Capanna technique describes a hybrid mode of reconstruction. Mass allograft is combined with a vascularised fibula autograft, allowing the patient to benefit from the favourable characteristics of two popular reconstruction techniques. Allograft confers initial mechanical stability with autograft contributing osteogenic, inductive and conductive capacity to encourage union. Secondarily its inherent vascularity affords the construct the ability to withstand deleterious effects of stressors such as infection that may threaten union. The strengths of this hybrid construct we believe can be used within the context of critical-sized bone defects within tibial trauma to the same success as seen within tumour reconstruction.

Methodology

Utilising the Capanna technique in trauma requires modification to the original procedure. In tumour surgery pre-operative cross-sectional imaging is a pre-requisite. This allows surgeons to assess margins, plan resections and order allograft to match the defect. In trauma this is not possible. We therefore propose a two-stage approach to address critical-sized tibial defects in open fractures. After initial debridement, external fixation and soft tissue management via a combined orthoplastics approach, CT imaging is performed to assess the defect geometry, with a polymethylmethacrylate (PMMA) spacer placed at index procedure to maintain soft tissue tension, alignment and deliver local antibiotics. Once comfortable that no further debridement is required and the risk of infection is appropriate then 3D printing technology can be used to mill custom jigs. Appropriate tibial allograft is ordered based on CT measurements. A pedicled fibula graft is raised through a lateral approach. The peroneal vessels are mobilised to the tibioperoneal trunk and passed medially into the bone void. The cadaveric bone is prepared using the custom jig on the back table and posterolateral troughs made to allow insertion of the fibula, permitting some hypertrophic expansion. A separate medial incision allows attachment of the custom jig to host tibia allowing for reciprocal cuts to match the allograft. The fibula is implanted into the allograft, ensuring nil tension on the pedicle and, after docking the graft, the hybrid construct is secured with multi-planar locking plates to provide rotational stability. The medial window allows plate placement safely away from the vascular pedicle.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 49 - 49
17 Apr 2023
Cooper G Kennedy M Jamal B Shields D
Full Access

Our objective was to conduct a systematic review and meta-analysis, comparing differences in clinical outcomes between either autologous or synthetic bone grafts in the operative management of tibial plateau fractures: a traumatic pattern of injury, associated with poor long-term functional prognosis.

A structured search of MEDLINE, EMBASE, The Bone & Joint and CENTRAL databases from inception until 07/28/2021 was performed. Randomised, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture non-union or chondral defects were excluded. Outcome data was assessed using the Risk of Bias 2 (ROB2) framework and synthesised in random-effect meta-analysis. Preferred Reported Items for Systematic Review and Meta-Analysis guidance was followed throughout.

Six comparable studies involving 352 patients were identified from 3,078 records. Following ROB2 assessment, five studies (337 patients) were eligible for meta-analysis. Within these studies, more complex tibia plateau fracture patterns (Schatzker IV-VI) were predominant. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference −0.45mm, p=0.25, 95% confidence interval (95%CI): −1.21-0.31mm, I2=0%) and long-term (>6 months, standard mean difference −0.56, p=0.09, 95%CI: −1.20-0.08, I2=73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, defect site pain, occurrence of surgical site infections, secondary surgery, perioperative blood loss, and duration of surgery. Blood loss was lower (90.08ml, p<0.001, 95%CI: 41.49-138.67ml, I2=0%) and surgery was shorter (16.17minutes, p=0.04, 95%CI: 0.39-31.94minutes, I2=63%) in synthetic treatment groups. All other secondary measures were statistically comparable.

Our findings supersede previous literature, demonstrating that synthetic bone grafts are non-inferior to autologous bone grafts, despite their perceived disadvantages (e.g. being biologically inert). In conclusion, surgeons should consider synthetic bone grafts when optimising peri-operative patient morbidity, particularly in complex tibial plateau fractures, where this work is most applicable.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 6 - 8
1 Oct 2022
Jamal B Calder P


Aims

Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures.

Methods

A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 41 - 41
1 Dec 2021
Brachimi E Rodger C Brown M Jamal B
Full Access

Abstract

Objectives

Currently, the golden standard for the management of ankle fractures is open reduction and internal fixation (ORIF), a procedure which preserves joint anatomy and function. However, ORIF is associated with high risk of infection, especially in the elderly population, who tend to suffer from osteoporosis and vascular disease. Studies recommend hindfoot nailing (HFN) as a safe and efficient management alternative for this demographic. Unlike ORIF, HFN allows immediate weight-bearing, which has been linked to a lower rate of complications. This study aims to evaluate the outcomes of hindfoot nailing in ankle fractures using a case series of 43 patients.

Methods

This is a retrospective study with a sample size of 43 patients, that have a mean age of 77.3 years and several medical conditions. These patients experienced ankle fractures that were treated with HFN. Data collected included injury patterns, operative complications, rate of radiological union, comorbidities and changes in mobility and housing before and after surgery.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 9 - 9
1 May 2021
Nicholas P Shields D Jamal B
Full Access

Introduction

During its conception, Ilizarov advocated a fine wire tension of between 900N and 1200N for circular frame construction. Wire tension can be achieved via a tensioning device or ‘Russian tensioning’ (a fixed wire lengthening around a bolt). There is limited information on the latter technique. This study aimed to explore the tensions achieved via Russian tensioning and report the impact of a second wire on construct tension.

Materials and Methods

A single 160mm stainless-steel ring was constructed, then 1.8mm stainless steel wires secured using a Russian fixation bolt and Russian tensioned with a 2nd bolt. The angle subtended by tensioning using the 2nd bolt was measured using a goniometer. Angles of 45°, 70° and 90° were repeated in triplicates, with wire tension measured using a calibrated tensiometer. A 2nd orthogonal wire was placed on the opposite side and tensioned to the same angle. Tensions of both wires were remeasured and recorded. Statistical comparison using unpaired t-tests was used to compare mean tensions. A value of p<0.05 was considered significant.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 16 - 16
1 May 2021
Shields D Lewandowski2 K McBride A Kaczmarczyk L Jamal B
Full Access

Introduction

Circular frame fixation has become a cornerstone of non-union and deformity management since its inception in the 1950s. As a consequence of modularity and heterogenous patient and injury factors, the prediction of the mechanobiological environment within a defect is subject to wide variations in practice. Given these wide range of confounding variables, clinical and cadaveric experimentation is close to impossible and frame constructs are based upon clinician experience. The Finite Element Analysis (FEA) method provides a powerful tool to numerically analyse mechanics. This work aims to develop an FEA model of a tibial defect and predict the mechanical response within the construct.

Materials and Methods

The geometry of a tibia was acquired via CT and a series of bone defects were digitally created in the tibial diaphysis. A 4-ring, 10-wire Ilizarov fixator was constructed using 180mm stainless steel rings and 1.8mm stainless steel wires tensioned to 1200N. An axial load (800N) was applied to simulate single leg stance of an 80kg patient. The magnitude of displacement was measured for defects with varying sizes (5–40mm). A numerical analysis was performed in large-strain regime using open-source FEA library (MoFEM).


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_8 | Pages 1 - 1
1 May 2021
MacDonald DRW Neilly DW Davies PSE Crome CR Jamal B Gill SL Jariwala AC Stevenson IM Ashcroft GP
Full Access

The aim of this study was to identify the effect of COVID-19 lockdown on the rates, types, mechanisms and mortality of musculoskeletal trauma across Scotland.

Data for all musculoskeletal trauma requiring operative treatment was collected prospectively from five orthopaedic units across Scotland during the initial lockdown period (23/03/2020-28/05/2020). This was compared with data for the same timeframe in 2018 and 2019. Data collected included all cases requiring surgery, injury type, mechanism of injury, and inpatient mortality.

1315 patients received operative treatment in 2020 compared to 1791 in 2019 and 1719 in 2018. The numbers of all injury types decreased, but the relative frequency of hip fractures increased(36.3% 2020 vs 30.2% 2019, p<0.0001 & 30.7% 2018, p<0.0001). Significant increases were seen in proportion of DIY-related injuries(3.1% 2020 vs 1.7% 2019, p=0.01 & 1.6% 2018, p<0.01) and injuries caused by falls(65.6% 2020 vs 62.6% 2019, p=0.08 & 61.9% 2018, p=0.05). Significant decreases were seen in proportion of RTCs(2.6% 2020 vs 5.4% 2019, p<0.0001 & 4.2% 2018, p=0.02) and occupational injuries(1.8% 2020 vs 3.0% 2019, p=0.03 & 2.3% 2018, p=0.01). A significant increase in proportion of self-harm injuries was seen(1.7% 2020 vs 1.1% 2019, p=0.19 & 0.5% 2018, p<0.0001). Mortality of trauma patients was significantly higher in 2020 (4.9%), than in 2019 (3.2%, p=0.02) and 2018 (2.6%, p<0.0001).

In conclusion, lockdown has resulted in a marked reduction of musculoskeletal trauma requiring surgery in Scotland. There have been major changes in types and mechanisms of injury, and mortality of trauma patients has risen significantly.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_8 | Pages 4 - 4
1 May 2021
Nicholas PRM Shields DW Mthethwa J Jamal B
Full Access

Gavril Ilizarov advocated a fine wire tension of between 900N and 1200N for circular frame construction. Wire tension can be achieved via a tensioning device or ‘Russian tensioning’ (a fixed wire lengthening around a bolt). There is limited information on the latter technique. This study explored the tensions achieved via Russian tensioning and reports the impact of a second wire on construct tension.

A single 160mm stainless-steel ring was constructed, then 1.8mm stainless steel wires were secured using a Russian fixation bolt and Russian tensioned with a 2nd bolt. The angle subtended by tensioning using the 2nd bolt was measured using a goniometer. Angles of 45°, 70° and 90° were repeated in triplicates, with wire tension measured using a calibrated tensiometer. A second, orthogonal wire was added and tensioned to the same angle. Tensions of both wires were remeasured and recorded. Unpaired t-tests were used to compare mean tensions. A value of p<0.05 was considered significant.

Tensioning at all angles was insufficient to achieve the target range of 900–1200N (range 99–110N). A second, orthogonal wire changed frame dynamics such that a 90° angle resulted in both wires achieving adequate tension (mean 1143N, SD 307N). Increases were significant across all tensioning angles (p=<0.002) however only biomechanically relevant for 90°.

Russian tensioning is insufficient with a single wire, however the addition of an orthogonal wire increases tension in both wires, reaching the target range at 90° deflection. Further study using wire tensioners is warranted, and also the impact of non-orthogonal wire constructs.


Bone & Joint Open
Vol. 1, Issue 9 | Pages 541 - 548
8 Sep 2020
MacDonald DRW Neilly DW Davies PSE Crome CR Jamal B Gill SL Jariwala AC Stevenson IM Ashcroft GP

Aims

The UK government declared a national lockdown on 23 March 2020 to reduce transmission of COVID-19. This study aims to identify the effect of lockdown on the rates, types, mechanisms, and mortality of musculoskeletal trauma across Scotland.

Methods

Data for all musculoskeletal trauma requiring operative treatment were collected prospectively from five key orthopaedic units across Scotland during lockdown (23 March 2020 to 28 May 2020). This was compared with data for the same timeframe in 2019 and 2018. Data collected included all cases requiring surgery, injury type, mechanism of injury, and inpatient mortality.


Bone & Joint Open
Vol. 1, Issue 7 | Pages 415 - 419
15 Jul 2020
Macey ARM Butler J Martin SC Tan TY Leach WJ Jamal B

Aims

To establish if COVID-19 has worsened outcomes in patients with AO 31 A or B type hip fractures.

Methods

Retrospective analysis of prospectively collected data was performed for a five-week period from 20 March 2020 and the same time period in 2019. The primary outcome was mortality at 30 days. Secondary outcomes were COVID-19 infection, perioperative pulmonary complications, time to theatre, type of anaesthesia, operation, grade of surgeon, fracture type, postoperative intensive care admission, venous thromboembolism, dislocation, infection rates, and length of stay.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 25 - 25
1 Nov 2016
Halai M Jamal B David-West K
Full Access

Treatment for Freiberg's disease is largely conservative. For severe disease and refractory cases, there are various surgical options. Most studies are from the Far-Eastern population and have short follow-up. The purpose of this study was to report the 5 year clinical outcomes of a dorsal closing wedge osteotomy in the treatment of advanced Freiberg´s disease in a Caucasian population.

Twelve patients (12 feet), with a mean age of 30.7 years (range 17–55), were treated with a synovectomy and a dorsal closing wedge osteotomy of the affected distal metatarsal. There were 10 females and 2 males. All patients were born in the United Kingdom. Clinical outcomes were independently evaluated pre and postoperatively using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring system and a subjective satisfaction score. Nine (75%) feet involved the 2nd metatarsal and 3 feet (25%) involved the 3rd metatarsal. According to the Smillie classification, 6 feet were Grade IV and 6 feet were grade V. Radiological union was evaluated postoperatively.

No patients were lost to follow up and the mean follow-up time was 5.2 years (4–7). AOFAS scores improved from 48.1 +/− 7.4 to 88.9 +/− 10.1 postoperatively (p< 0.001) giving a mean improvement of 40.8. 92% of patients were satisfied with their operation at latest follow-up, reporting excellent or good results. All patients had postoperative radiological union. One patient had a superficial postoperative infection that was successfully treated with oral antibiotics.

A dorsal closing wedge osteotomy is an effective treatment of advanced Freiberg´s disease in a Caucasian population, with good outcomes and few complications.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 47 - 47
1 Oct 2016
Halai M Jamal B Robinson P Qureshi M Kimpton J Syme B McMillan J Holt G
Full Access

Three distal femoral axes have been described to aid in alignment of the femoral component; the Trans Epicondylar Axis (TEA), the Posterior Condylar Axis (PCA) and the Antero Posterior (AP) axis. Our aim was to identify if there was a reproducible relationship between the axes which would aid alignment of the femoral component. This is the first study compare all three distal femoral axes with each other using magnetic resonance imaging (MRI) in a Caucasian population. Our sample group represents real life patients awaiting total knee arthroplasty (TKA), as opposed non-arthritic or cadaveric knees.

We identified the relationship between these rotational axes by performing MRI scans on 89 patients awaiting TKA with patient-specific instrumentation. Measurements were taken by two observers.

Patients had a mean age of 62.5 years (range 32–91). 51 patients were female. The mean angle between the TEA and the AP axis was 92.78° with a standard deviation of 2.51° (range 88° – 99°). The mean angle between the AP axis and the PCA was 95.43° with a standard deviation of 2.75° (range 85° – 105°). The mean angle between the TEA and the PCA was 2.78° with a standard deviation of 1.91° (range 0° – 10°).

We conclude that while there is a reproducible relationship between the differing femoral axes, there is a significant range in the relationship between the femoral axes. This range may lead to greater inaccuracy than has previously been appreciated when defining the rotation of the femoral component. There is most variation between the PCA and the AP axis. The TEA's relationship with the PCA and AP appears important in defining rotation. Due to the well accepted difficulty in defining the TEA intra-operatively, there may be a role for patient-specific instrumentation in TKA surgery with pre-operative MRI.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_17 | Pages 8 - 8
1 Dec 2015
Jamal B Virdy G Aitya S Madeley N Kumar C
Full Access

Calcaneal fracture fixation over the past decade has been practised via an extensile lateral incision. This can be complicated by infection and wound breakdown.

We have developed a new technique for fixation of the calcaneal fractures – MACO. We utilise a 4 cm sub fibular incision to aid joint visualisation and fracture reduction. Fixation is via percutaneous screws.

We analysed our prospectively collected database. 26 fractures were fixed over an 18 month period at Glasgow Royal Infirmary by three consultant surgeons. 22 patients were male and half were smokers. Mean follow up was 5 months (range 1.5 – 18 months).

The mean age of our patients is 41 (range 25–68). The mean pre operative Bohler's angle was 16.7 degrees. Gissane's angle was similarly abnormal with a mean of 129 degrees.

The average duration of surgery was 73 minutes (range 45–100 minutes). Post operatively, Bohler's angle was improved. The mean was 29 degrees. There was no significant difference with Gissane's angle. The mean was 128 degrees.

There were no superficial wound infections. One patient was troubled by wound breakdown with subsequent deep infection. There was no need for metalwork removal in our series of patients. Two patients developed post traumatic osteoarthritis of the sub talar joint. Only one has required sub talar joint fusion.

We conclude that the novel technique which we describe is successful in restoring calcaneal anatomy with few complications. Further follow up is needed to determine the long term outcomes of such surgery.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 10 - 10
1 Apr 2014
Halai M Jamal B Robinson P Qureshi M Kimpton J Syme B McMillan J Holt G
Full Access

Three distal femoral axes have been described to aid in alignment of the femoral component; the Trans Epicondylar Axis (TEA), the Posterior Condylar Axis (PCA) and the Antero Posterior (AP) axis. Our aim was to identify if there was a reproducible relationship between the axes. Hopefully this will aid the surgeon to more accurately judge the rotation of the femoral cutting block by using the axes with the least variation. This is the first study compare all three distal femoral axes with each other using magnetic resonance imaging (MRI) in a Caucasian population awaiting total knee arthroplasty (TKA).

We identified the relationship between these axes by performing MRI scans on 89 patients awaiting TKA with patient-specific instrumentation. Measurements were taken by two observers.

Patients had a mean age of 62.5 years (range 32–91). 51 patients were female. The mean angle between the TEA and AP axis was 92.78°, standard deviation (SD) 2.51° (range 88°–99°). The mean angle between the AP axis and PCA was 95.43°, SD 2.75° (range 85°–105°). The mean angle between the TEA and PCA was 2.78°, SD 1.91° (range 0°–10°).

We conclude that while there is a reproducible relationship between the differing femoral axes, there is a significant range in the relationship between the femoral axes. This range may lead to greater inaccuracy than has previously been appreciated when defining the rotation of the femoral component. There is most variation between the PCA and the AP axis. Most systems have a cutting block with 3° of external rotation from the PCA and this would be parallel to the TEA in the majority, but not all, cases in this series. This data suggests that if the surgeon is to pick two axes to reference from, one should include the TEA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 11 - 11
1 Aug 2013
Jamal B Pillai A Fogg Q Kumar S
Full Access

The anatomy of the first metatarsophalangeal (MTP) joint and, in particular, the metatarsosesamoid articulation remains poorly understood. Its effect on sesamoid function and the pathomechanics of this joint have not been described.

Fresh frozen cadaveric specimens without evidence of forefoot deformity were dissected to assess the articulating surfaces throughout a normal range of motion. The dissections were digitally reconstructed in various positions of dorsiflexion and plantarflexion using a MicroScribe, enabling quantitative analyses in a virtual 3D environment.

In 75% of specimens, there was some degree of chondral loss within the metatarsosesamoid articulation. The metatarsal surface was more commonly affected. These changes most frequently involved the tibial metatarsosesamoid joint.

The tibial sesamoid had an average excursion of 14.2 mm in the sagittal plane when the 1st MTP joint was moved from 10 degrees of plantarflexion to 60 degrees of dorsiflexion; the average excursion of the fibular sesamoid was 8.7 mm. The sesamoids also move in a medial to lateral fashion when the joint was dorsiflexed. The excursion of the tibial sesamoid was 2.8 mm when the joint was maximally dorsiflexed while that of the fibular sesamoid was 3.2 mm.

There appears to be differential tracking of the hallucal sesamoids. The tibial sesamoid has comparatively increased longitudinal excursion whilst the fibular sesamoid has comparatively greater lateral excursion.

This greater excursion of the tibial sesamoid could explain the higher incidence of sesamoiditis in this bone. The differential excursion of the 2 metatarsosesamoid articulations is also a factor that should be considered in the design and mechanics of an effective hallux MTP joint arthroplasty.