Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 48 - 48
1 Jan 2016
Horiuchi H Akizuki S Nakamura Y Toyota T
Full Access

Background

There are some critical points of Cruciate retaining (CR) TKA. We recognized that it is one of the most important issue how to manage for release of PCL contracture. PCL contracture would lead to poor ROM, stiff or painful knee after CR TKA. PCL release at insertion of femoral / tibial side or cut in PCL itself, “pie craft” were reported. However, for retaining of PCL function after TKA, peeling off PCL itself would be not desirable. Therefore, we proposed to perform V shape-osteotomy at PCL insertion of tibia with osteotome (Fig.1,2) and cancellous bone graft at osteotomy site to get bony union (V-shape osteotomy with cancellous bone graft: VOCG). We would present how to perform VOCG at CR TKA and clinical results.

Patients and Methods

188 knees in 126 patients were received NRG CR TKA (Stryker) at Nagano Matsushiro General Hospital between February 2008 and August 2009. Mean age at operation was 75.1±5.9 years old. The indications for VOCG were positive of POLO test positive, inadequate soft tissue balance because of PCL contracture, or poor pre-operative ROM et al. All patients were reviewed with clinical and radiographic assessments. Clinical evaluation was carried out using the Knee Society Score (knee score and functional score). The range of motion (ROM) was pre- and post-operatively. In order to evaluate the effect of VOCG, clinical outcomes were compared between two groups (with VOCG vs without VOCG).


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 592 - 596
1 May 2008
Akizuki S Shibakawa A Takizawa T Yamazaki I Horiuchi H

We carried out a prospective study of 132 patients (159 knees) who underwent closed-wedge high tibial osteotomy for severe medial compartment osteoarthritis between 1988 and 1997. A total of 94 patients (118 knees) was available for review at a mean of 16.4 years (16 to 20). Seven patients (7.4%) (11 knees) required conversion to total knee replacement. Kaplan-Meier survival was 97.6% (95% confidence interval 95.0 to 100) at ten years and 90.4% (95% confidence interval 84.1 to 96.7) at 15 years. Excellent and good results as assessed by the Hospital for Special Surgery knee score were achieved in 87 knees (73.7%). A pre-operative body mass index > 27.5 kg/m2 and range of movement < 100° were risk factors predicting early failure.

Although our long-term results were satisfactory, strict indications for osteotomy are required if long-term survival is required.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 410 - 410
1 Apr 2004
Saito N Kobayashi S Nawata M Horiuchi H Ota H
Full Access

A prospective randomized study was performed to evaluate the role of cold therapy in the postoperative treatment of total hip arthroplasty (THA). Forty consecutive patients underwent primary total hip arthroplasty for osteoarthritis. All components were not cemented. The patients were randomized: 20 were fitted with a cold therapy device for four days, and 20 were not. They were evaluated in terms of blood loss, creatine phosphokinase (CPK) level, C-reactive protein (CRP) level, and pain relief. No significant difference was found in the amount of postoperative wound drainage between the two groups of patients. The use of cold compressive dressing after THA was not associated with an increase in CPK and CRP level.

The pain score in the postoperative period of THA was significantly lower in the cold therapy group than in the control group. The results of this study support the potential benefit in pain reduction by use of the cold compressive device in the postoperative recovery of patients undergoing THA.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 406 - 406
1 Apr 2004
Kobayashi S Saito N Nawata M Horiuchi H Oota H Iorio R Takaoka K
Full Access

Polyethylene wear is the most important risk factor affecting the durability of total knee arthroplasty. We developed a new method of measuring wear of the tibial polyethylene insert in total knee arthroplasty (TKA) on standard standing radiographs.

Methods: We developed a new method of measuring the shortest distance between the femoral component and the tibial metal tray taking its 3-D position into consideration. The accuracy of the method was examined in 3 conditions. An in vitro examintion measured the thickness of the polyethylene on radiographs of a new PFC prosthesis set on a table. The radiographs were taken from various directions. An in vivo examination measured the polyethylene thickness on patient discharge radiographs of 78 knees. These measurements were compared with known thicknesses of the used inserts. In the third study, wear of the tibial polyethylene insert was measured retrospectively in a series of 84 PFC TKAs with follow-up of 2 to 10 years (6.6 years on average).

Results: The average measurement error was 0.05 mm (SD 0.09 mm) in the in vitro study and 0.14 mm (SD 0.17 mm) in the in vivo study using discharge radiographs. In the series of 84 PFC TKAs, impending failure occurred in 7 knees, 4 of which were revised. Radiographically measured wear of the tibial insert was significantly greater in these failed TKAs than in the other TKAs. The radiographic measurements were well correlated with 3-D measurements of 4 retrieved inserts.

Discussion: Although the radiographic measurement of the tibial insert in TKA was less accurate than that of the socket in THA, it is useful enough to identify TKAs at risk of failure. When the radiographic wear exceeded 1mm, there was a significantly increased probability of impending failure or need for revision.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 412 - 412
1 Apr 2004
Nawata M Kobayashi S Saito N Horiuchi H Ohta H Takaoka K
Full Access

By 1998, 10 patients had undergone 12 revision total knee arthroplasties at our institute. One patient died three weeks after surgery due to cerebral infarction, leaving 11 knees of nine patients for evaluation. Average follow-up was 4.8 years (1 to 9 years). All components were subjected to revision surgery in five knees, the tibial tray and insert in four knees, and only the insert in two knees. Patients were evaluated with clinical examinations, radiographs, and the Knee Society Clinical Rating System.

After revision surgery, the Knee Scores and ROMs were restored to almost the same level as just after the first TKA. Re-revision was performed on two patients, one 103 months and the other 82 months after revision TKA. In those two patients, huge bone loss of the proximal tibial canal was filled with cement without bone graft. The other patients, however whose tibial trays were fixed with cement on adequate grafted bone obtained good results.

The femoral components that were not treated with revision surgery despite small flaws or scratches due to wear and tear of the tibial insert did not cause marked wear of the new tibial insert.

Conclusion: Bone loss of the proximal tibial canal should be filled with bone graft, not with cement only. Femoral components with small flaws or scratches, and without other ploblems, need not to be treated with revision surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1123 - 1127
1 Nov 2003
Akizuki S Takizawa T Horiuchi H

Miller-Galante II total knee arthroplasty (MG II TKA) was performed on 32 knees in 30 patients. On both the femoral and tibial components, the fibre-metal area was plasma-sprayed with hydroxyapatite-tricalcium phosphate (HA-TCP). The clinical and radiographic outcome was evaluated. A mean pre-operative knee score of 26.0 ± 18.6 (SD) increased to 97.5 ± 3.5 and a mean pre-operative functional score of 21.7 ± 15.0 (SD) increased to 83.4 ± 12.4 at follow-up of seven years. Clear zones were common around the components at one month post-operatively but had completely disappeared after six months. An autopsy of a patient who underwent MG II TKA with HA-TCP two years previously, showed osteogenesis in all parts of the fibre-metal, and bone tissue comprised 77.7% of the interface. This coated prosthesis has good early fixation which is maintained at seven years with good clinical and radiographic outcomes.