header advert
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 17 - 17
1 Dec 2022
Ciapetti G Granchi D Perut F Spinnato P Spazzoli B Cevolani L Donati DM Baldini N
Full Access

Fracture nonunion is a severe clinical problem for the patient, as well as for the clinician. About 5-20% of fractures does not heal properly after more than six months, with a 19% nonunion rate for tibia, 12% for femur and 13% for humerus, leading to patient morbidity, prolonged hospitalization, and high costs.

The standard treatment with iliac crest-derived autologous bone filling the nonunion site may cause pain or hematoma to the patient, as well as major complications such as infection.

The application of mesenchymal autologous cells (MSC) to improve bone formation calls for randomized, open, two-arm clinical studies to verify safety and efficacy.

The ORTHOUNION * project (ORTHOpedic randomized clinical trial with expanded bone marrow MSC and bioceramics versus autograft in long bone nonUNIONs) is a multicentric, open, randomized, comparative phase II clinical trial, approved in the framework of the H2020 funding programme, under the coordination of Enrique Gòmez Barrena of the Hospital La Paz (Madrid, Spain).

Starting from January 2017, patients with nonunion of femur, tibia or humerus have been actively enrolled in Spain, France, Germany, and Italy.

The study protocol encompasses two experimental arms, i.e., autologous bone marrow-derived mesenchymal cells after expansion (‘high dose’ or ‘low dose’ MSC) combined to ceramic granules (MBCP™, Biomatlante), and iliac crest-derived autologous trabecular bone (ICAG) as active comparator arm, with a 2-year follow-up after surgery.

Despite the COVID 19 pandemic with several lockdown periods in the four countries, the trial was continued, leading to 42 patients treated out of 51 included, with 11 receiving the bone graft (G1 arm), 15 the ‘high dose’ MSC (200x106, G2a arm) and 16 the ‘low dose’ MSC (100x106, G2b arm).

The Rizzoli Orthopaedic Institute has functioned as coordinator of the Italian clinical centres (Bologna, Milano, Brescia) and the Biomedical Science and Technologies and Nanobiotechnology Lab of the RIT Dept. has enrolled six patients with the collaboration of the Rizzoli’ 3rd Orthopaedic and Traumatological Clinic prevalently Oncologic.

Moreover, the IOR Lab has collected and analysed the blood samples from all the patients treated to monitor the changes of the bone turnover markers following the surgical treatment with G1, G2a or G2b protocols.

The clinical and biochemical results of the study, still under evaluation, are presented.

* ORTHOUNION Horizon 2020 GA 733288


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 35 - 35
1 Apr 2017
Ciapetti G Fotia C Granchi D Rojewski M Rosset P Gómez-Barrena E Baldini N
Full Access

Background

Delayed bone healing and nonunion are complications of long bone fractures, with prolonged pain and disability. Regenerative therapies employing mesenchymal stromal cells (MSC) and/or bone substitutes are increasingly applied to enhance bone consolidation. Within the REBORNE project, a multi-center orthopaedic clinical trial was focused on the evaluation of efficacy of expanded autologous bone marrow (BM) derived MSC combined with a CaP-biomaterial to enhance bone healing in patients with nonunion of diaphyseal fractures. To complement the clinical and radiological examination of patients, bone turnover markers (BTM) were assayed as potential predictors of bone healing or non-union.

Methods

Bone-specific alkaline phosphatase (BAP), C-terminal-propeptide type I-procollagen (PICP), osteocalcin (OC), β-Cross-Laps Collagen (CTX), soluble receptor activator of NFkB (RANKL), osteoprotegerin (OPG) were measured by ELISA assays in blood samples of 22 patients at BM collection and at follow-ups (6, 12 and 24 weeks post-surgery).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 113 - 113
1 Jan 2017
Boriani F Granchi D Roatti G Merlini L Sabattini T Baldini N
Full Access

The postoperative course of median nerve decompression in the carpal tunnel syndrome may sometimes be complicated by postoperative pain, paresthesias, and other unpleasant symptoms, or be characterized by a slow recovery of nerve function due to prolonged preoperative injury causing extensive nerve damage.

The aim of this study is to explore any possible effects of alpha lipoic acid (ALA) in the postoperative period after surgical decompression of the median nerve at the wrist.

Patients were enrolled with proven carpal tunnel syndrome and randomly assigned into one of two groups: Group A: surgical decompression of the median nerve followed by ALA for 40 days. Group P: surgical decompression followed by placebo. The primary endpoint of the study was nerve conduction velocity at 3 months post surgery, Other endpoints were static 2 point discrimination, the Boston score for hand function, pillar pain and use of pain killers beyond the second postoperative day.

ALA did not show to significantly improve nerve conduction velocity or Boston score. However, a statistically significant reduction in the postoperative incidence of pillar pain was noted in Group A. In addition, static 2 point discrimination showed to be significantly improved by ALA.

Administration of ALA following decompression of the median nerve for carpal tunnel release is effective on nerve recovery, although this is not detectable through nerve conduction studies but in terms of accelerated and improved static two-point discrimination.

The use of ALA as a supplementation for nerve recovery after surgical decompression may be extended to all types of compression syndromes or conditions where a nerve is freed from a mechanical insult.

Furthermore, ALA limits post-decompression pain, including late pericicatricial pain at the base of the palm, the so called pillar pain, which seems to be associated with a reversible damage to the superfical sensitive small nerve fibers.

In conclusion postoperative administration of ALA for 40 days post-median nerve decompression was positively associated with nerve recovery, induced a lower incidence of postoperative pillar pain and was associated with a more rapid improvement of static two-point discrimination. This treatment is well tolerated and associated with high levels of satisfaction and compliance, supporting its value as a standard postoperative supplementation after carpal tunnel decompression.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 11 - 11
1 Jan 2017
Ciapetti G Granchi D Barrena EG Rojewski M Rosset P Layrolle P Donati D Spazzoli B Baldini N
Full Access

Delayed bone healing and nonunion are complications of long bone fractures, with prolonged pain and disability. Regenerative therapies employing mesenchymal stromal cells (MSC) and/or bone substitutes are increasingly applied to enhance bone consolidation. The REBORNE project entailed a multi-center orthopaedic clinical trial focused on the evaluation of efficacy of expanded autologous bone marrow (BM) derived MSC combined with a CaP-biomaterial, to enhance bone healing in patients with nonunion of diaphyseal fractures. To complement the clinical and radiological examination of patients, bone turnover markers (BTM) were assayed as potential predictors of bone healing or non-union.

Peripheral blood was collected from patients at fixed time-endpoints, that is at 6,12 and 24 weeks post-surgery for implantation of expanded autologus MSC and bone-like particles. Bone-specific alkaline phosphatase (BAP), C-terminal-propeptide type I-procollagen (PICP), osteocalcin (OC), β-Cross-Laps Collagen (CTX), soluble receptor activator of NFkB (RANKL), osteoprotegerin (OPG) were measured by ELISA assays in blood samples of 22 patients at BM collection and at follow-up visits.

A significant relationship with age was found only at 6 months, with an inverse correlation for CTX, RANKL and OC, and positive for OPG. BTM levels were not related to gender. As an effect of local regenerative process, some BTM showed significant changes in comparison to the baseline value. In particular, the time course of BAP, PICP and RANKL was different in patients with a successful healing in comparison to patients with a negative outcome. The BTM profile apparently indicated a remarkable bone formation activity 12 weeks after surgery. However, the paucity of failed patients in our case series did not allow to prove statistically the role of BTM as predictors of the final outcome.

Blood markers related to bone cell function are useful to measure the efficacy of a expanded MSC-regenerative approach applied to long bone non-unions. Changes of the markers may provide a support to radiological assessment of bone healing.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 105 - 105
1 Jul 2014
Bonuccelli G Avnet S Fotia C Salerno M Grisendi G Granchi D Dominici M Baldini N
Full Access

Summary

Reciprocal metabolic reprogramming of MSCs and osteosarcoma cells influences tumor-stroma cross talk. Drugs targeting Warburg metabolism may define innovative therapeutic approaches in osteosarcoma.

Introduction

Osteosarcoma (OS) is a malignant primary bone tumour of mesenchymal origin, in which cells with stem-like characteristics (CSCs) have been described. Recent studies have demonstrated a mutual interaction between stroma and tumor cells in exploiting a role in the pathogenesis and progression of cancer, and also in the enhancing stemness phenotype. Here we take in consideration the complex juxtacrine and paracrine intercellular cross talk played by mesenchymal stromal cells (MSCs) with adherent osteosarcoma cells and OS cells with stem-like characteristics (CSCs).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 9 - 9
1 Jul 2014
Di Pompo G Granchi D Poli F Lorenzi B Mandrone M Baldini N
Full Access

Summary Statement

In this study it has been considered an alternative therapeutic approach to bone resorption diseases by using plant decoctions to improve adherence from patients to the treatment. In this context, Hemidesmus indicus represents a possible therapeutic or adjuvant natural compound.

Introduction

The acceleration of bone remodelling, with an excessive osteoclastogenesis or activation of mature osteoclasts, causes the loss of bone mass which is implicated in bone resorption diseases. Conventional therapies are expensive and limited by systemic toxicity and low drug bioavailability. Alternative treatments that are not only effective but also administered employing formulations and dosages different from conventional ones, may improve adherence to therapy, having a positive influence on clinical outcomes. Experimental evidence have attributed antiproliferative and apoptosis inducing activity on different cell lines (including osteoclast precursors or mature osteoclasts) to four plants used in Ayurvedic medicine: Asparagus racemosus (AR), Emblica officinalis (EO), Hemidesmus indicus (HI) and Rubia cordifolia (RC) These properties could be helpful in the treatment of some bone resorption diseases. In order to clarify the possible therapeutic effects of these compounds, the anti-osteoclast activity of their decoctions were evaluated.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1126 - 1134
1 Aug 2012
Granchi D Cenni E Giunti A Baldini N

We report a systematic review and meta-analysis of the peer-reviewed literature focusing on metal sensitivity testing in patients undergoing total joint replacement (TJR). Our purpose was to assess the risk of developing metal hypersensitivity post-operatively and its relationship with outcome and to investigate the advantages of performing hypersensitivity testing.

We undertook a comprehensive search of the citations quoted in PubMed and EMBASE: 22 articles (comprising 3634 patients) met the inclusion criteria. The frequency of positive tests increased after TJR, especially in patients with implant failure or a metal-on-metal coupling. The probability of developing a metal allergy was higher post-operatively (odds ratio (OR) 1.52 (95% confidence interval (CI) 1.06 to 2.31)), and the risk was further increased when failed implants were compared with stable TJRs (OR 2.76 (95% CI 1.14 to 6.70)).

Hypersensitivity testing was not able to discriminate between stable and failed TJRs, as its predictive value was not statistically proven. However, it is generally thought that hypersensitivity testing should be performed in patients with a history of metal allergy and in failed TJRs, especially with metal-on-metal implants and when the cause of the loosening is doubtful.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 571 - 576
1 Apr 2005
Savarino L Granchi D Cenni E Baldini N Greco M Giunti A

There is no diagnostic, non-invasive method for the early detection of loosening after total hip arthroplasty. In a pilot study, we have analysed two serum markers of bone remodelling, procollagen I C-terminal extension peptide (PICP) and cross-linked N-terminal telopeptide (NTx), as well as the diagnostic performance of NTx for the assessment of osteolysis. We recruited 21 patients with loosening (group I), 18 with a well-fixed prosthesis (group II) and 17 at the time of primary arthroplasty for osteoarthritis (OA) (group III). Internal normal reference ranges were obtained from 30 healthy subjects (group IV).

The serum PICP level was found to be significantly lower in patients with OA and those with loosening, when compared with those with stable implants, while the NTx level was significantly increased only in the group with loosening, suggesting that collagen degradation depended on the altered bone turnover induced by the implant. This hypothesis was reinforced by the finding that the values in the pre-surgery patients and stable subjects were comparable with the reference range of younger healthy subjects.

A high specificity and positive predictive value for NTx provided good diagnostic evidence of agreement between the test and the clinical and radiological evaluations. The NTx level could be used to indicate stability of the implant. However, further prospective, larger studies are necessary.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 56 - 56
1 Mar 2005
Granchi D
Full Access

Metals represent the main components of orthopaedic implants. Being in contact with biological fluids, the metallic alloys used for the fabrication of artificial joints undergo corrosion or degradation, therefore they release ions and molecules. Although these do not have antigenic properties, they bind to protein carriers and may act as haptens eliciting a delayed-type hypersensitivity reaction (DTH). Biomaterial-related hypersensitivity is considered as an immunotoxic effect, although little is known about its clinical incidence and its impact on implant failure. The main question about the sensitivity against metals used in the joint prosthesis concern the cause-effect relation with the implant failure. In metal-exposed workers, the diagnosis of DTH is made in vivo by patch testing. For the occupational exposure standard patch-testing protocols are available, but some concerns exist about their applicability to study the hypersensitivity to metal implants. In this case-control study, a panel of representative haptens was used to assess the incidence of positive patch testing in patients undergoing ‘total hip replacement’ (THR) and ‘total knee replacement’ (TKR). The main goal of this study was to evaluate the validity of this relatively simple and safe procedure in the diagnosis of the hypersensitivity reactions to the implant components.

A consecutive series of 286 individuals was enrolled in the study. Five groups of patients were evaluated: Group A included 75 patients (20 M; 55 F; median age 59) candidates to primary THR or TKR; Group B included 98 patients with loosening of THR (27 M; 71 F; median age 67; median follow up: 102 months); Group C included 53 patients with stable THR (13 M; 40 F; median age 68; median follow up: 60 months); Group D included 40 patients with failed TKR (14 M; 26 F; median age 68; median follow up: 24 months); Group E included 20 patients with stable TKR (4 M; 16 F; median age 70; median follow up: 16 months). Osteoarthritis was the most frequent disease that led to joint replacement (59%), followed by hip dysplasia (19%), and trauma (13%). Patients with rheumatoid arthritis were excluded from the study, as well as patients who assumed cortico-steroids or other immunosuppressive drugs.

Fifty-eight patients (21%) had an additional implant at another site. Hypersensitivity to metals was tested by using the most relevant components of Cobalt-Chromium based alloys (CoCrMo), Ti-based alloys (TiAlV), and bone cements. A drop of each hapten was smeared on the Haye’s chamber test, which was applied to the dorsum of the patient. After 48–72 hours, skin reactions were evaluated and graded as 0 (no reaction), 1 (erythema), 2 (edema), 3 (vesicles), or 4 (bulla).

All patients with a medical history of metal DTH showed positive skin reaction. The incidence of positive patch testing to at least one hapten, as well as the frequency of DTH to metal, resulted significantly higher in patients with TKR, while the incidence of positive skin testing to bone cements was similar in all groups. Group B patients with CoCrMo-THR showed a low frequency of nickel-DTH in comparison to Group A (9% and 22%, respectively). In patients with TiAlV-THR the immune status seemed to be unaffected, and these individuals showed a high incidence of vanadium-DTH (Group A: 8%; Group B: 21%; Group C: 19%; p= 0.04). A high incidence of vanadium hypersensitivity was found also in patients with TKR (Group D: 33%; Group E: 20%). The median duration of the implant resulted significantly lower in patients who had a positive patch testing to metals (71 vs 106 months; p= 0.008).

Our results demonstrated the reliability of the panel used for skin testing, which was able to identify a systemic hypersensitivity status. A remarkable finding concerned the prevalence of DTH related to the metal composition of the implant. A significant low frequency of metal DTH, namely nickel, was found in patients with CoCrMo-failed implant. Because nickel is the most common metal sensitizer and its amount in both CoCrMo and TiAlV alloys is very low, we may consider the incidence of nickel DTH as informative for the immune status of the examined group. In the TiAlV group the immune status seems to be unaffected; on the contrary, theese patients showed a high prevalence of vanadium skin reaction. These results confirm the conclusion of previous studies, where the immunocompromised status of patients who had a CoCrMo had been shown and related to the high serum level of chromium and cobalt. Although the cause-effect relation between DTH and implant failure cannot be established, the hypersensitivity should be considered when deciding what type of prosthesis to use. Either if the sensitization precedes or follows the loosening, it participates in the network of events that are responsible for prosthetic loosening, because contributes to mantain the inflammatory process.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 758 - 764
1 Jul 2003
Granchi D Savarino L Ciapetti G Cenni E Rotini R Mieti M Baldini N Giunti A

We aimed to assess whether the immunological abnormalities which have been observed in patients with loose total hip replacements (THRs) are present in patients with a well-fixed prosthesis.

We examined blood samples from 39 healthy donors, 22 patients before THR and 41 with well-fixed THRs of different types (15 metal-on-metal, 13 metal-on-polyethylene, 13 ceramic-on-ceramic). Before THR, the patients showed a decrease in leukocytes and myeloid cells in comparison with healthy donors, and a prevalence of type-1 T lymphocytes, which was confirmed by the increase in ratio of interferon-γ to interleukin 4. Moreover, patients with metal-on-metal or metal-on-polyethylene implants showed a significant decrease in the number of T lymphocytes and a significant increase in the serum level of chromium and cobalt, although no significant correlation was observed with the immunological changes. In the ceramic-on-ceramic group, leukocytes and lymphocyte subsets were not significantly changed, but a significant increase in type-2 cytokines restored the ratio of interferon-γ to interleukin 4 to normal values.

We conclude that abnormalities of the cell-mediated immune response may be present in patients with a well-fixed THR, and that the immunological changes are more evident in those who have at least one metal component in the articular coupling.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 912 - 917
1 Sep 1998
Granchi D Verri E Ciapetti G Stea S Savarino L Sudanese A Mieti M Rotini R Dallari D Zinghi G Montanaro L

Our aim was to determine if the serum levels of bone-resorbing cytokines (IL-1β, TNF-α, IL-6, GM-CSF) are altered in patients with aseptic loosening of a total hip prosthesis, and if such levels are influenced by the type of implant. We determined cytokine levels in sera from 35 patients before revision for failed total hip arthroplasty and compared them with those in 25 healthy donors. We also assessed the soluble receptor of interleukin-2 (sIL-2r) in serum as an indication of a specific immune reaction against the implant.

Our findings showed that the sIL-2r and TNF-α serum level did not change. The IL-6 level was not significantly altered, but was higher in patients with TiAlV prostheses than in those with a CrCoMo implant and in patients with cemented prostheses. The IL-1β level was found to be higher in those with a TiAlV cemented prosthesis than in the control group (p = 0.0001) and other groups of patients (p = 0.003 v uncemented TiAlV, p = 0.01 v cemented CrCoMo, p = 0.001 v uncemented CrCoMo). The GM-CSF level significantly increased in patients compared with healthy subjects (p = 0.008), and it was higher in those with cemented than with uncemented implants (p = 0.01). Only patients with cementless CrCoMo prostheses had levels of GM-CSF similar to those of the control group. The highest GM-CSF concentrations were observed in patients treated with non-steroidal anti-inflammatory drugs (NSAIDs) in the last months before revision (p = 0.04). In addition, when massive osteolysis was observed, the level of GM-CSF tended to decrease to that of the control group.