header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 20 - 20
1 Oct 2018
Galea V Connelly J Matuszak S Botros MA Rojanasopondist P Nielsen C Huddleston J Bragdon C Malchau H Troelsen A
Full Access

Introduction

The aim of this study was to evaluate the effects of posterior tibial slope (PTS) and posterior condylar offset (PCO) on patient-reported pain and function one year after TKA.

Methods

A total of 500 patients from 11 clinics in 6 countries were enrolled into a prospective, multicenter study. All patients were indicated for primary TKA for OA and received components from a single manufacturer. All liners were made from vitamin-E stabilized, highly crosslinked (95 kGy) polyethylene; 54.7% were posterior stabilized (PS) and the remaining were cruciate-retaining.

The Knee Injury and Osteoarthritis Outcome Score (KOOS) was administered at the one-year follow-up visit. The KOOS pain and activities in daily life (ADL) sub-scores were dichotomized and served as the primary outcomes. Dichotomization was done with the patient acceptable symptom state (PASS), defined by previous studies as the value of the PROM above which patients deem their state as acceptable (84.5 points for KOOS pain and 83.0 points for KOOS ADL).

Plain lateral radiographs were taken and assessed for PTS (Figure 1) and PCO (Figure 2). PTS was categorized as above (excessive flexion), within (ideal), or below (extension) the safe zone of 0° − 7° of flexion. PCO increases or decreases of greater than 3mm were compared against no change (≤ 3mm). Each of the two sagittal positioning metrics was tested against the KOOS pain and ADL PASS at one year.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 36 - 36
1 Aug 2018
Muratoglu O Galea V Connelly J Shareghi B Kärrholm J Sköldenberg O Salemyr M Laursen M Bragdon C Malchau H
Full Access

The primary purpose of the current study was to evaluate and compare the wear properties of vitamin E-doped, highly-crosslinked PE (VEPE) and one formulation of moderately cross-linked and mechanically-annealed ultra-high molecular weight PE (ModXLPE) in patients five years after primary THA. We also sought to understand whether polyethylene wear is associated with radiographic evidence of bone resorption or with deterioration in patient-reported outcome measures (PROMs).

A total of 221 patients from four international centers were recruited into a prospective RSA and clinical outcomes study. Seventy percent (76%) of patients received VEPE (vs. ModXLPE) liners, and 36% received ceramic (vs. metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA radiographs were collected to measure PE wear.

We observed similar bedding in through the one-year interval and wear through the two-year interval between the two liner types. However, there was significantly more femoral head penetration in the ModXLPE cohort compared to the VEPE cohort at the five-year follow-up (p<0.001). The only variables independently predictive of increased wear were ModXLPE (vs VEPE) liner type (β=0.22, p=0.010) and metal (vs. ceramic) femoral head type (β=0.21, p=0.013). There was no association between increased wear and radiolucency development (p=0.866) or PROMs. No patients were found to have evidence of osteolysis.

At five-years postoperatively, patients treated with VEPE (vs. ModXLPE) and ceramic (vs. metal) femoral heads demonstrated decreased wear. At the longest follow-up (five years postoperatively), the wear rates for both liner groups were very low and have not led to any osteolysis or implant failures via aseptic loosening.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 25 - 25
1 Jan 2018
Malchau H Galea V Connelly J Shareghi B Kärrholm J Sköldenberg O Laursen M Bragdon C Muratoglu O
Full Access

Osteolysis secondary to ultra-high molecular weight polyethylene (UHMWPE) wear is a leading cause of late-term implant failure via aseptic loosening in patients treated with total hip arthroplasty (THA). Radiation crosslinking of UHMWPE has been shown to decrease wear. However, the resulting polymer (crosslinked-PE) has a high free radical content. Two different methods that have been used to reduce the remaining free radicals are mechanical annealing and chemical stabilization using Vitamin E, a free radical scavenger.

The primary purpose of the current study was to evaluate and compare the wear properties of vitamin E-doped crosslinked-PE (VEPE) and one formulation of mechanically annealed crosslinked-PE using radiostereometric analysis (RSA) in patients five years after primary THA. We also sought to understand the association between polyethylene wear and patient-reported outcome measures (PROMs).

Three-hundred and five patients from six international centers were enrolled. Seventy-six percent were treated with highly-crosslinked (95 kGy) VEPE liners, and the rest received moderately-crosslinked (50 kGy) (ModXL), mechanically annealed liners. Data was collected prospectively at one-, two-, and five-year intervals.

At the 5-year follow-up, proximal femoral head penetration into the VEPE liners (median = 0.05mm (range, −0.03–1.20)) was significantly lower than the penetration into the ModXL liners (median = 0.15mm (range, −0.22–1.04)) (p<0.001). In the VEPE cohort the median proximal penetration did not increase from one- to five-year follow-up (p=0.209). In contrast, there was a significant increase in femoral head penetration for the ModXL group (p<0.001) during that same time. Multivariable regression showed that the only variable predictive of increased wear was ModXL liner type (B=0.12, p<0.001). There were no differences in PROMs between the liner groups, and there was no correlation between polyethylene wear and PROMs for the cohort as a whole.

The current study is the largest analysis of polyethylene wear at five-year follow-up using the RSA technique. We observed similar bedding in through the two-year interval between the two liner types, however, there was significantly more wear in the ModXL cohort at five-years. Currently, the wear rates for both liner groups are below the osteolysis threshold and have not led to any implant failures via aseptic loosening. Continued follow-up will provide a better understanding of the association between wear rate and clinical outcomes.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 100 - 100
1 Feb 2017
Bragdon C Donahue G Lindgren V Galea V Madanat R Muratoglu O Malchau H
Full Access

Introduction

Complication and revision rates have shown to be high for all metal-on-metal (MoM) bearings, especially for the ASR Hip System (ASR hip resurfacing arthroplasty (HRA) and ASR XL total hip arthroplasty (THA)). This prompted the global recall of the ASR Hip System in 2010. Many studies have previously explored the association between female gender and revision surgery MoM HRA implants; yet less research has been dedicated to exploring this relationship in MoM THA.

The first purpose of this study was to assess the associations between gender and implant survival, as well as adverse local tissue reaction (ALTR), in patients with MoM THA. Secondly, we sought to report the differences between genders in metal ion levels and patient reported outcome measures (PROMs) in patients with MoM THA.

Methods

The study population consisted of 729 ASR XL THA patients (820 hips) enrolled from September 2012 to June 2015 in a multicenter follow-up study at a mean of 6.4 (3–11) years from index surgery. The mean age at the time of index surgery was 60 (22–95) years and 338 were women (46%). All patients enrolled had complete patient and surgical demographic information, blood metal ion levels and PROMs obtained within 6 months, and a valid AP pelvis radiograph dating a maximum of 2 years prior to consent. Blood metal ion levels and PROMs were then obtained annually after enrollment. A sub-set of patients from a single center had annual metal artifact reduction sequence (MARS) MRI performed and were analyzed for the presence of moderate-to-severe ALTR.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 128 - 128
1 Feb 2017
Bragdon C Galea V Donahue G Lindgren V Troelsen A Marega L Muratoglu O Malchau H
Full Access

Introduction

Studies of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) have reported high complication and failure rates due to elevated metal ion levels. These rates were shown to be especially high for the Articular Surface Replacement (ASR) HRA, possibly due to its unique design. Associations between metal ion concentrations and various biological and mechanical factors have been reported. Component positioning as measured by acetabular inclination has been shown to be of especially strong consequence in metal ion production in ASR HRA patients, but few studies have evaluated acetabular anteversion as an independent variable.

The primary objective of this study was to evaluate the associations between component orientation, quantified by acetabular inclination and anteversion, and blood metal ions. Secondly, we sought to report whether conventional safe zones apply to MoM HRA implants or if these implants require their own positioning standards.

Methods

We conducted a multi-center, prospective study of 512 unilateral ASR HRA patients enrolled from September 2012 to June 2015. At time of enrollment our patients were a mean of 7 (3–11.5) years from surgery. The mean age at surgery was 56 years and 24% were female. All subjects had complete demographic and surgical information and blood metal ions. In addition, each patient had valid AP pelvis and shoot-though lateral radiographs read by 5 validated readers measuring acetabular abduction and anteversion, and femoral offset. A multivariate logistic regression was used with high cobalt or chromium (greater than or equal to 7ppb) as the dependent variable. The independent variables were: female gender, UCLA activity score, age at surgery, femoral head size, time from surgery, femoral offset, acetabular abduction, and acetabular anteversion.