header advert
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 33 - 33
1 Dec 2021
Logoluso N Balato G Pellegrini AV De Vecchi E Romanò CL Drago L Lenzi M Ascione T
Full Access

Aim

Despite the availability of numerous tests, the diagnosis of periprosthetic infection (PJI) continues to be complex. Although several studies have suggested that coagulation-related markers, such as D-dimer and fibrinogen, may be promising tools in the diagnosis of prosthetic infections, their role is still controversial. The aim of this study is to evaluate the diagnostic accuracy of serum D-dimer and fibrinogen in patients with painful total knee replacement.

Method

83 patients with painful total knee replacement and suspected peri-prosthetic infection were included. All patients underwent pre-operative blood tests to evaluate inflammation indices (ESR and CRP) and serum D-Dimer and Fibrinogen levels. The diagnostic performance of the tests was assessed using the ICM definition as the gold standard. The diagnostic accuracy of the D-dimer and fibrinogen was measured by assessing sensitivity, specificity and by calculating the area under the ROC curve.


Bone & Joint Research
Vol. 8, Issue 5 | Pages 199 - 206
1 May 2019
Romanò CL Tsuchiya H Morelli I Battaglia AG Drago L

Implant-related infection is one of the leading reasons for failure in orthopaedics and trauma, and results in high social and economic costs. Various antibacterial coating technologies have proven to be safe and effective both in preclinical and clinical studies, with post-surgical implant-related infections reduced by 90% in some cases, depending on the type of coating and experimental setup used. Economic assessment may enable the cost-to-benefit profile of any given antibacterial coating to be defined, based on the expected infection rate with and without the coating, the cost of the infection management, and the cost of the coating. After reviewing the latest evidence on the available antibacterial coatings, we quantified the impact caused by delaying their large-scale application. Considering only joint arthroplasties, our calculations indicated that for an antibacterial coating, with a final user’s cost price of €600 and able to reduce post-surgical infection by 80%, each year of delay to its large-scale application would cause an estimated 35 200 new cases of post-surgical infection in Europe, equating to additional hospital costs of approximately €440 million per year. An adequate reimbursement policy for antibacterial coatings may benefit patients, healthcare systems, and related research, as could faster and more affordable regulatory pathways for the technologies still in the pipeline. This could significantly reduce the social and economic burden of implant-related infections in orthopaedics and trauma.

Cite this article: C. L. Romanò, H. Tsuchiya, I. Morelli, A. G. Battaglia, L. Drago. Antibacterial coating of implants: are we missing something? Bone Joint Res 2019;8:199–206. DOI: 10.1302/2046-3758.85.BJR-2018-0316.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2018
Zagra L De Vecchi E Bortolin M Romanò C Drago L
Full Access

Reliability of microbiological diagnosis of prosthetic joint infection [PJI] strongly depends on the ability to dislodge microorganisms from biofilm and on the rate of contaminating samples during collection in the operating room and processing. The aim of a correct protocol is to avoid false negative and false positive results in order to adapt the correct therapy for each patient.

The object of the present study was to evaluate the impact of a novel closed bag system designed for samples collection and processing based on dithiothreitol (DTT), which is a sulfydryl compound able to remove bacteria from biofilm (MicroDTTect, 4i, Italy), on isolation of contaminant microorganisms in hip prostheses.

Specimens (prostheses, spacers, periprosthetic tissues) were aseptically collected according to a standard protocol into the device, which was transported to the laboratory for culture. Three different models of the system were prospectively evaluated, each being a development of the previous one. The first generation device consisted in an “open” system (DTT eluate was collected with a syringe and dispensed into sterile tubes), the second generation device in a “partially closed” system (DTT eluate collected directly in sterile vacuum tubes) and the third generation device in a “completely closed system” (DTT reservoir directly connected with sealed tubes inside the device). PJI was diagnosed following criteria established by MSIS.

The overall contamination rate, sensitivity and specificity of the first generation “open” system MicroDTTect were respectively 2.6% (1/39), 82.3% and 95.4% in 39 hips. The second generation “partially closed” device was characterized by a contamination rate of 1.96% (1/51), a sensitivity of 84% and a specificity of 96.1% in 51 hips. Contamination rate further decreased in the third generation “closed” system (1.89%, 2/106), while sensitivity (91.3%) and specificity (96.7%) improved in 106 hips. Differences have been also observed in hips (106) when compared to knees (70 cases) prosthetic infections (sensitivity 91.3% vs 89.3% and specificity 96.7% vs 100%).

Our data show as, thanks to its ease of use, low contamination rate and high sensitivity, MicroDTTect can represent a useful tool for improving the microbiological diagnosis of PJIs in hip revisions and has replaced sonication in our practice.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 28 - 28
1 Dec 2017
Bortolin M Bidossi A Toscano M De Vecchi E Romanò CL Mattina R Drago L
Full Access

Aim

Biofilm-related infections represent a recurrent problem in the orthopaedic setting. In recent years, great interest was directed towards the identification of novel molecules capable to interfere with pathogens adhesion and biofilm formation on implant surfaces. In this study, two stable forms of α-tocopherol, the hydrophobic acetate ester and the water-soluble phosphate ester, were tested in vitro as coating for titanium prostheses.

Method

Antimicrobial activity against microorganisms responsible of prosthetic and joints infections was assessed by broth microdilution method. In addition, α-tocopherol esters were evaluated for both their ability to hamper bacterial adhesion and biofilm formation on sandblasted titanium surfaces.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 90 - 90
1 Jan 2017
Gallazzi E Bortolin M Romanò D Drago L Romanò C
Full Access

Development of antibacterial surfaces or coatings to prevent bacterial adhesion and hence colonization of implants and biofilm formation is an attractive option, in order to reduce the tremendous impact of implant-related infections associated with modern surgery. To overcome the lack of in vivo and clinical models, able to evaluate the performance of anti-adhesive coatings, we designed an in vitro experimental setting that allows to quantitatively evaluate the ability of a coating to reduce bacterial adhesion on a given surface; this model may efficiently serve as a surrogate endpoint to validate anti-adhesive medical devices and compounds. Here we report the results the evaluation of the anti-adhesive properties of a patented, fast-resorbable hydrogel coating, (“Defensive Antibacterial Coating”, DAC).

Sterile sandblasted titanium discs of approximately 5cm2 surface area were used as substrates for bacterial adhesion. The gel was prepared as follows: syringes prefilled with 300 mg of DAC powder (Novagenit Srl) were reconstituted with 5 ml of sterile water to obtain a hydrogel with a DAC concentration of 6%. Two experiments were conducted. In the first, 200 mg of hydrogel were homogenously spread on the surface of titanium disc, with the spreading device provided by the manufacturer. Both coated and uncoated substrates (controls) were overlaid with a standardized inoculum (108 CFU/ml) of a wild methicillin-resistant Staphylococcus aureus strain, previously isolated from a peri-prosthetic joint infection, for 15, 30, 60 and 120 minutes. Afterwards, non-adherent bacteria were removed by rinsing with sterile saline. The remaining adhered cells were seeded on agar plates for CFU count. In the second experiment, the discs were first inoculated with bacterial cells followed by a treatment with the hydrogel and bacterial count as described above. Ten discs were used for each condition and each time interval (total 160 discs).

The adhesion density of S. aureus on titanium discs pre-treated with DAC was significantly lower than that observed on untreated controls at each time point. In particular, the average number of adherent bacteria at 15, 30, 60 and 120 minutes of incubation, was respectively reduced by 86.8%, 80.4%, 74.6% and 66.7%, compared to controls (p<0.001). DAC treatment of discs with previously adhered S. aureus reduced bacterial adhesion, at 15, 30, 60 and 120 minutes of incubation, by, respectively, 84.0% (p<0.05), 72.8%, 72.3% and 64.3% (p<0.001), compared to untreated controls.

Our results shows that DAC, “Defensive Antibacterial Coating”, has anti-adhesive properties that allow to reduce bacterial adhesion on a sanded titanium surface by more than 80%, even in the presence of remarkably high bacterial loads (108 CFU/ml), of multi-resistant bacteria (MRSA) and even in the case of previous contamination. Providing anti-adhesive properties to a surface with a fast-resorbable coating may be a safe option to protect inorganic and organic surfaces and biomaterials. Those observation could be the pre-requisite for its in vivo application.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 15 - 15
1 Dec 2016
Morelli I Drago L George D Gallazzi E Scarponi S Romanò C
Full Access

Aim

The induced membrane technique (IMT) or Masquelet technique is a two-step surgical procedure used to treat bony defects (traumatic or resulting from tumoral resections) and pseudo arthroses, even caused by infections. The relatively small case series reported, sometimes with variants to the original technique, make it difficult to assess the real value of the technique. Aim of this study was then to undertake a systematic review of the literature with a particular focus on bone union, infection eradication and complication rates.

Method

A systematic review was carried out following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses for Individual Patient Data (PRISMA-IPD) guidelines. PubMed and other medical databases were searched using “Masquelet technique” and “induced membrane technique” keywords. English, French or Italian written articles were included if dealing with IMT employed to long bones in adults and reporting at least 5 cases with a 12 months minimum follow-up. Clinical and bone defect features, aetiology, surgical data, complications, re-interventions, union and infection eradication rates were recorded into a database. Fischer's exact test and unpaired t-test were used for the statistical analysis on the individual patient's data.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 43 - 43
1 Dec 2016
Romanò C Malizos K Blauth M Capuano N Mezzoprete R Logoluso N Drago L
Full Access

Aim

Aim of this study is to present the first clinical trial on an antibiotic-loaded fast-resorbable hydrogel coating*, in patients undergoing internal osteosynthesis for closed fractures.

Method

In this prospective, multi-centre, randomized, controlled, prospective study, a total of 260 patients were randomly assigned, in five European orthopaedic centres, to receive the antibiotic-loaded DAC coating or to a control group, without coating. Pre- and post-operative assessment of laboratory tests, wound healing, clinical scores and x-rays were performed at fixed time intervals.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 80 - 80
1 Dec 2016
Malizos K Capuano N Mezzoprete R D'Arienzo M Van Der Straeten C Drago L Romanò C
Full Access

Aim

Infection remains among the first reasons of failure of joint prosthesis. According to various preclinical reports, antibacterial coatings of implants may prevent bacterial adhesion and biofilm formation. Aim of this study is to present the first clinical trial on an antibiotic-loaded fast-resorbable hydrogel coating*, in patients undergoing hip or knee prosthesis.

Method

In this multi-center, randomized, prospective, study, a total of 380 patients, scheduled to undergo primary or revision total hip or knee joint replacement, using a cementless or a hybrid implant, were randomly assigned, in six European orthopedic centers, to receive the antibiotic-loaded DAC coating or to a control group, without coating. Pre- and post-operative assessment of clinical scores, wound healing, laboratory tests and x-ray were performed at fixed time intervals.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 33 - 33
1 Dec 2016
Trentinaglia MT Drago L Logoluso N Morelli I Romanò C
Full Access

Aim

Implant-related infections, including peri-prosthetic joint infection (PJI) and infected osteosynthesis, are biofilm-related. Intra-operative diagnosis and pathogen identification is currently considered the diagnostic benchmark; however the presence of bacterial biofilm(s) may have a detrimental effect on pathogen detection with traditional microbiological techniques. Sonication and chemical biofilm debonding have been proposed to overcome, at least partially, this issue, however little is known about their possible economical impact. Aim of this study was to examine direct and indirect hospital costs connected with the routine use of anti-biofilm microbiological techniques applied to hip and knee PJIs.

Method

In a first part of the study, the “Turn Around Time (TAT)” and direct costs comparison between a system to find bacteria on removed prosthetic implants*, a closed system for intra-operative tissue and implant sampling, transport and anti-biofilm processing, versus sonication has been performed. An additional analysis of the estimated indirect hospital costs, resulting from the diagnostic accuracy of traditional and anti-biofilm microbiological processing has been conducted.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 104 - 104
1 Dec 2015
De Vecchi E Villa F Agrappi S Toscano M Drago L
Full Access

Culture examination is still considered the gold standard for diagnosis of bone and joint infections, including prosthetic ones, even if in up to 20–30% of cases, particularly prosthetic joint infections, it fails to yield microbial growth. To overcome this limitation, determination of markers of inflammation and or infection directly in joint fluid has been proposed.

Aim of this study was to evaluate the applicability of measurement of lecukocyte esterase (LE), C-reactive protein (CRP) and glucose in synovial fluid for diagnosis of bone and joint infections.

Synovial fluids from 80 patients were aseptically collected and sent to laboratory for microbiological cultures. After centrifugation at 3000 rpm for 10 minutes, pellet was used for cultures, while the surnatant was used for determination of LE, CRP and glucose. LE and glucose were evaluated by means of enzymatic colorimetric strips developed for urinanalysis. One drop of synovial fluid was placed on the LE and on the glucose pads and the results were read after about 120 seconds. A LE test graded + or ++, and a glucose test equal to trace or negative were considered suggestive for infection. CRP was measured by an automated turbidimetric method.

On the basis of clinical findings, microbiological, haematological and histological analyses patients were retrospectively divided into 2 groups. Group 1 comprised 19 infected patients (12 males, 7 females age: 70.6 ± 10.3 yrs, range: 47 – 88 yrs) while Group 2 included 61 aseptic patients (32 males and 29 females, age: 61.5 ± 16.3 yrs, range: 15 – 84). Sensitivity of the three tests was 89.5%. 84% and 73,7% for LE, CRP and glucose, respectively. Specificity was 98.4%, 88.5% and 70% for LE, CRP and glucose, respectively. Positive and negative predictive values were 94.4% and 96.8% for LE, 69.6% and 94.6% for CRP and 77.8% and 89.6% for glucose test. When LE was combined with CRP, sensitivity increased to 94.7%, while no differences were observed for LE combined with glucose.

Leukocyte esterase has proven to be a rapid, simple and inexpensive test to rule in or out bone and joint infections. Combination of its measurement with that of CRP increased sensitivity. In conclusion, the combination of leukocyte esterase and CRP may represent a simple and useful tool for diagnosis of bone and joint infections.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 20 - 20
1 Dec 2015
Galliera E Drago L Romano C Marazzi M Vassena C Romanelli MC
Full Access

Post operative prosthetic joint infection (PJI) is the most common cause of failure of total joint arthroplasty, requiring revision surgery, but a gold standard for the diagnosis and the treatment of PIJ is still lacking [1].

SuPAR, the soluble urokinase plasminogen activation receptor, has been recently described as a powerful diagnostic and prognostic tool, able not only to detect sepsis but also to discriminate different grade of sepsis severity [2,3]

This study aimed to examine the diagnostic value of SuPAR in post operative PJI, in order to explore the possible application of this new biomarker in the early diagnosis of PJI.

The level of SuPAR have been measured in PJI patients and controls (patients undergoing prosthesis revision without infection), and correlated with pro and anti inflammatory markers (CRP C-reactive protein, IL-6, IL-1 TNFα, IL-10, IL-12, IL-8, IL1ra and the chemokine CCL2).

Statistical analysis of Receiver Operating Characteristic (ROC) curves and Area Under the Curve (AUC) was performed

As described in Figure 1, serum SuPAR displayed a strongly significative increase in PJI patients compared to not infected controls, and a significative positive correlation with C-reactive protein, IL-6, IL-1 and TNFα and the chemokine CCL2.

SuPAR displayed a very good AUC, significantly higher than CRP and IL-6 AUC

This study clearly show that the measure of Serum level of SuPAR provide a extremely important benefit because it is a precise indicator of bacterial infection, and the addition of SuPAR serum level measurement to classical inflammatory markers can strongly improve the diagnosis of prosthesis joint infection

The authors acknowledge ViroGates, Denmark for providing suPARNOSTIC Standard Kit.

The authors would also acknowledge the Italian Ministero dell’ Istruzione, Università e Ricerca (MIUR) and Italian Ministero della Salute for providing funds for this research project.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 17 - 17
1 Dec 2015
George D Volpin A Scarponi S Drago L Haddad F Romano C
Full Access

The best surgical modality for treating chronic periprosthetic shoulder infections has not been established, with a lack of randomised comparative studies. This systematic review compares the infection eradication rate and functional outcomes after single- or two-stage shoulder exchange arthroplasty, to permanent spacer implant or resection arthroplasty.

Full-text papers and those with an abstract in English published from January 2000 to June 2014, identified through international databases, were reviewed. Those reporting the success rate of infection eradication after a single-stage exchange, two-stage exchange, resection arthroplasty or permanent spacer implant were included, with a minimum follow-up of 6 months and sample size of 5 patients.

Eight original articles reporting the results after resection arthroplasty (n = 83), 6 on single-stage exchange (n = 75), 13 on two-stage exchange (n = 142) and 8 papers on permanent spacer (n = 68) were included.

The average infection eradication rate was 86.7% at a mean follow-up of 39.8 months (SD 20.8) after resection arthroplasty, 94.7% at 46.8 months (SD 17.6) after a single-stage exchange, 90.8% at 37.9 months (SD 12.8) after two-stage exchange, and 95.6% at 31.0 months (SD 9.8) following a permanent spacer implant. The difference was not statistically significant.

Regarding functional outcome, patients treated with single-stage exchange had statistically significant better postoperative Constant scores (mean 51, SD 13) than patients undergoing a two-stage exchange (mean 44, SD 9), resection arthroplasty (mean 32, SD 7) or a permanent spacer implant (mean 31, SD 9) (p=0.029). However, when considering studies comparing pre- and post-operative Constant scores, the difference was not statistically significant.

This systematic review failed to demonstrate a clear difference in infection eradication and functional improvement between all four treatment modalities for established periprosthetic shoulder infection. The relatively low number of patients and the methodological limitations of the studies available point out the need for well designed multi-center trials to further assess the best treatment option of peri-prosthetic shoulder infection.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 77 - 77
1 Dec 2015
Toscano M De Vecchi E Drago L
Full Access

The role of biofilm in pathogenesis of several chronic human infections is widely accepted, as this structure leads pathogens to persist among the human body, being protected from the action of antibacterial molecules and drugs (1). It has been estimated that up to 65% of bacterial infections are caused by microorganisms growing in biofilms (2). Moreover, biofilm is involved in device-related orthopaedic bacterial infections, which are unaffected by vaccines and antibiotic therapies, constituting a serious problem for the human health care.

The aim of the present work was to evaluate the anti-biofilm action of a selected and patented lactobacillus strain (MD1) supernatant, both on the in-formation- biofilm and on mature biofilm produced by pathogenic bacteria.

MD1 was grown in BHI for 48 h at 37°C. After incubation, the sample was centrifuged for 5’ for 14,000 × g and the supernatant previously filtered and treated in order to obtain the anti-biofilm compounds (Special Supernatant – SS) was collected. Staphylococcus aureus and Pseudomonas aeruginosa strains were grown in BHI for 24h at 37°C. The anti-biofilm ability of the tested SS – lactobacillus strain was evaluated by a spectrophotometric method according to Christensen at al., following the incubation of pathogens and the “mature biofilm” with the lactobacillus supernatant. Confocal Laser Scanning Microscopy was used to confirm the data obtained from Crystal Violet Assay.

After the incubation of the SS with pathogens and mature biofilm, the formation of biofilm was inhibited and a significant disruption of the mature biofilm was observed. Interestingly, the same properties were observed also when the SS pH was neutralized to pH 6.5. In particular, the reduction of biofilm production and the disruption of mature biofilm was about 50–70% for all microorganisms.

The SS lactobacillus strain MD1 exhibited a relevant antibiofilm action against mature and in-formation-biofilm produced by S. aureus and P. aeruginosa strains tested in the study. Moreover, the antibiofilm action has been observed to be pH-independent, as when the supernatant was neutralized to pH 6.5, the reduction of pathogenic biofilm has been still observed. These promising results highlighted the possibility to use this SS-lactobacillus anti-biofilm property to develop a cost-effective and safety treatment able to reduce the impact of pathogenic biofilm on device-related orthopaedic bacterial infections.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 88 - 88
1 Dec 2015
De Vecchi E Signori V Bortolin M Romanò C Drago L
Full Access

Prosthetic implants, periprosthetic and osteoarticular tissues are specimens of choice for diagnosis of bone and joint infections including prosthetic joint infections (PJIs). However, it is widely known that cultures from prostheses and tissues may fail to yield microbial growth in up to one third of patients. In the recent past, treatment of prosthetic implants have been optimized in order to improve sensitivity of microbiological cultures, while less attention has been addressed to tissue samples. For these latter homogenization is considered the best procedure, but it is quite laborious, time-consuming and it is not always performed in all laboratories. Dithiothreitol (DTT) has been proposed as an alternative treatment to sonication for microbiological diagnosis of PJIs. In this study, we evaluated the applicability of MicroDTTect treatment, a closed system developed for transport and treatment of tissues and prosthetic implants with DTT.

For evaluation of applicability of MicroDTTect to tissue specimens, samples (tissues and, in case of PJI, prosthetic implants) from 40 patients (12 PJIs and 5 osteomyelitis and 23 not-infected) were evaluated. MicroDTTect system consists of a sterile plastic bag containing a reservoir which allows for release of a 0.1% (v:v) DTT solution, once the sample is placed into the bag. Comparison of MicroDTTect treatment of prostheses with sonication included samples from 30 patients (14 with aseptic loosening of the prosthesis and 16 with PJIs). Of two tissue samples from the same region, one was placed into MicroDTTect bag and the other was collected in a sterile container with addition of sterile saline. After agitation and centrifugation of the eluate, aliquots of the pellets were plated on agar plates and inoculated into broths which were incubated for 48 hrs and 15 days, respectively.

Treatment of prosthetic implants with MicroDTTect showed a higher specificity and sensitivity than sonication (specificity 92.8% vs 85.7%; sensitivity: 87.5% vs 75.0 % DTT vs sonication). When used for tissue treatment, MicroDTTect showed a sensitivity of 82.3% and a specificity of 97% which were higher than that observed when saline was used (sensitivity: 64.7%; specificity 91%).

Treatment of tissues and prosthetic implants with MicroDTTect may be a practicable strategy to improve microbiological diagnosis of osteoarticular infections, reducing sample manipulation and therefore limiting sample contamination. Moreover, use of MicroDTTect does not require dedicated instrumentation, and is time and cost saving.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 284 - 284
1 Jul 2014
Meani E Fini M Giavaresi G Drago L Romanò C
Full Access

Summary Statement

An Implant Disposable Antibacterial Coating (i-DAC®) is described, consisting of a fully resorbable, biocompatible hydrogel, able to release antibacterial and antibiofilm agents. Direct application of the hydrogel on implants prevented infection occurrence in an in vitro model of peri-prosthetic infection.

Introduction

Biofilm-related infections are among the main reasons for failure of joint prosthesis with high associated social and economical costs. Bacterial adhesion and subsequent biofilm formation have been shown to develop early after biomaterials implant into the human body, when a “race to the surface” takes place between the host's cells and the colonizing bacteria eventually present at the surgical site. Providing an antibacterial/antibiofilm coating of the implant may then play a strategic role in preventing biofilm related infections. Here we report the results of a series of in vitro and in vivo studies, partially performed under the European 7th Framework Programme (Implant Disposable Antibiotic Coating, IDAC, collaborative research project # 277988), concerning a fully resorbable, biocompatible antibacterial hydrogel coating (DAC®, Novagenit, Italy). The patented hydrogel, a co-polimer comprising of hyaluronic acid and a polylactic acid, has been designed to be mixed with various antibacterial agents and applied directly on the implant at the time of surgery, being fully resorbed within few days.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 845 - 850
1 Jun 2014
Romanò CL Logoluso N Meani E Romanò D De Vecchi E Vassena C Drago L

The treatment of chronic osteomyelitis often includes surgical debridement and filling the resultant void with antibiotic-loaded polymethylmethacrylate cement, bone grafts or bone substitutes. Recently, the use of bioactive glass to treat bone defects in infections has been reported in a limited series of patients. However, no direct comparison between this biomaterial and antibiotic-loaded bone substitute has been performed.

In this retrospective study, we compared the safety and efficacy of surgical debridement and local application of the bioactive glass S53P4 in a series of 27 patients affected by chronic osteomyelitis of the long bones (Group A) with two other series, treated respectively with an antibiotic-loaded hydroxyapatite and calcium sulphate compound (Group B; n = 27) or a mixture of tricalcium phosphate and an antibiotic-loaded demineralised bone matrix (Group C; n = 22). Systemic antibiotics were also used in all groups.

After comparable periods of follow-up, the control of infection was similar in the three groups. In particular, 25 out of 27 (92.6%) patients of Group A, 24 out of 27 (88.9%) in Group B and 19 out of 22 (86.3%) in Group C showed no infection recurrence at means of 21.8 (12 to 36), 22.1 (12 to 36) and 21.5 (12 to 36) months follow-up, respectively, while Group A showed a reduced wound complication rate.

Our results show that patients treated with a bioactive glass without local antibiotics achieved similar eradication of infection and less drainage than those treated with two different antibiotic-loaded calcium-based bone substitutes.

Cite this article: Bone Joint J 2014; 96-B:845–50.