header advert
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 28 - 28
24 Nov 2023
De Vecchi E Balzano V Bottagisio M Gavioli L
Full Access

Aim

Antibacterial activity of coatings based on metal and metal oxide nanoparticles (NPs) often depends on materials and biotic targets resulting in a material-specific killing activity of selected Gram-positive and Gram-negative bacteria, including drug-resistant strains. In this perspective, the NPs loading amount, the relative elemental concentration inside the nanogranular building blocks and the deposition method are of paramount importance when the goal is to widen the antimicrobial spectrum, but at the same time to avoid high levels of metal content to limit undesired toxic effects. Aim of the present study was evaluation of the antimicrobial properties of two multielement nanogranular coatings composed of Titanium-Silver and Copper and of Magnesium-Silver and Copper.

Method

Ti-Ag-Cu and Mg-Ag-Cu NPs were deposited on circular cover glasses (VWR) by Supersonic Cluster Beam Deposition. Biofilm-producer strains of Staphylococcus aureus (methicillin susceptible and resistant), Staphylococcus epidermidis (methicillin susceptible and resistant), Escherichia coli (fully susceptible and producer of extended spectrum beta lactamases), and Pseudomonas aeruginosa (susceptible and multidrug-resistant) were selected. The abilities of the selected strains to adhere, colonize and produce biofilm on the discs coated with Ti-Ag-Cu or Mg-Ag-Cu NPs were compared to uncoated circular cover glasses which were used as growth control. Cytotoxicity was also evaluated in order to assess the biocompatibility of the newly synthesized NPs.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 7 - 7
1 Oct 2022
Bottagisio M Viganò M Zagra L Pellegrini A De Vecchi E
Full Access

Aim

The analysis of synovial fluid has proved to be of crucial importance in the diagnostic process of prosthetic joint infections (PJI), suggesting the presence of an infection before the microbiological culture results. In this context, several studies illustrated the efficacy of synovial calprotectin in supporting the diagnosis of PJI [1, 2]. However, several testing methods have been explored to detect synovial calprotectin levels, emphasizing the need to use a standardized, rapid and rapid test.

In this study, synovial calprotectin was analyzed by means of a commercial stool test [3] to explore whether the detected levels might predict PJIs and, therefore, being a promising tool for the fast and reliable diagnosis of this complication.

Method

The synovial fluid of 55 patients underwent to revision of the prosthetic implant were analyzed. The measurement of calprotectin was carried out by of commercial stool test, following the protocol for liquid samples. Calprotectin levels were then compared to other synovial biomarkers of PJI such as leucocyte esterase and count and percentage of polymorphonuclear cells.

Data analysis were performed using R software v4.1.1 (R Core Team) and package “pROC” [4]. Receiver operator characteristics curves were designed using culture test as gold standard to evaluate the area under curve (AUC) of each method (with DeLong method for confidence-interval calculation). Thresholds were calculated to maximize Youden's index; sensitivity and specificity were reported. One-to-one Pearson's correlations coefficient were calculated for each pair of methods. P value <0.05 were considered statistically significant.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 33 - 33
1 Dec 2021
Logoluso N Balato G Pellegrini AV De Vecchi E Romanò CL Drago L Lenzi M Ascione T
Full Access

Aim

Despite the availability of numerous tests, the diagnosis of periprosthetic infection (PJI) continues to be complex. Although several studies have suggested that coagulation-related markers, such as D-dimer and fibrinogen, may be promising tools in the diagnosis of prosthetic infections, their role is still controversial. The aim of this study is to evaluate the diagnostic accuracy of serum D-dimer and fibrinogen in patients with painful total knee replacement.

Method

83 patients with painful total knee replacement and suspected peri-prosthetic infection were included. All patients underwent pre-operative blood tests to evaluate inflammation indices (ESR and CRP) and serum D-Dimer and Fibrinogen levels. The diagnostic performance of the tests was assessed using the ICM definition as the gold standard. The diagnostic accuracy of the D-dimer and fibrinogen was measured by assessing sensitivity, specificity and by calculating the area under the ROC curve.


Aim

Bone and implant-associated infections caused by microorganisms that grow in biofilm are difficult to treat because of persistence and recurrence. Systemic administration of antibiotics is often inefficient because the poor vascularization of the site of infection. This issue has led to the development of biomaterials capable to locally deliver high doses of therapeutic agents to the injured bone with minimal systemic effects. In this context, calcium sulphate/hydroxyapatite (CS/HA) bone graft substitutes are widely used being safe, osteoconductive and resorbable biomaterials that can be easily enriched with consistent amounts of antibiotics. In this in vitro study, the capability of the eluted antibiotics to select the tested bacterial strains for antibiotic resistance was evaluated to confirm the safe use of the product.

Method

S. aureus, S. epidermidis and P. aeruginosa isolated in our Institute from bone and joint infection with different resistance phenotypes were used. 6 × 2.5 mm CS/HA discs were generated by pouring the antibiotic loaded formulations in a mold and were used as a modified disk diffusion test. The resistance selection was evaluated by subculturing cells growing on the edge of the zone of inhibition (ZOI) for seven days. Minimum inhibitory concentrations (MICs) of gentamicin and vancomycin were determined by broth microdilution method before and after the selection of resistance assay. In addition, MICs were assessed after seven day passage on antibiotic free agar plates to evaluate if eventual decrease of antibiotic susceptibility was stable or only transient.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 372 - 377
1 Apr 2019
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E

Aims

Leucocyte esterase (LE) has been shown to be an accurate marker of prosthetic joint infection (PJI), and has been proposed as an alternative to frozen section (FS) histology for intraoperative diagnosis. In this study, the intraoperative assessment of LE was compared with FS histology for the diagnosis of prosthetic hip infection.

Patients and Methods

A total of 119 patients undergoing revision total hip arthroplasty (THA) between June 2015 and December 2017 were included in the study. There were 56 men and 63 women with a mean age of 66.2 years (27 to 88). Synovial fluid was collected before arthrotomy for the assessment of LE using enzymatic colourimetric strips. Between five and six samples were stained with haematoxylin and eosin for FS histology, and considered suggestive of infection when at least five polymorphonuclear leucocytes were found in five high-power fields.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 27 - 27
1 Aug 2018
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E
Full Access

Leukocyte esterase (LE) has shown to be an accurate marker of prosthetic joint infections and has been proposed as an alternative to frozen section (FS) for intra-operative diagnosis. In this study, intra-operative determination of LE was compared with FS for the diagnosis of periprosthetic hip infections.

One hundred and nineteen patients undergoing hip revision surgery due to prosthetic joint failure from June 2015 to December 2017 were considered. Joint fluids were collected before the arthrotomy for determination of LE which was performed by using enzymatic colorimetric strips. Four to six samples were stained with hematoxylin eosin for FS and considered suggestive for infection when at least 5 polymorphonuclear leukocytes in 5 fields at high power fields were found.

Sensitivity and specificity of LE were 100% and 93.8 %, respectively. The positive predictive value was 79.3 %, while the negative predictive value was 100%. Time from collection to response was 20.1 ± 4.4 minutes.

Sensitivity and specificity of FS were 83.3 % and 92.1 %, respectively. The positive and negative predictive values were 84.6 % and 97.1%. Time from sample collection response was 27.2 ± 6.9 minutes.

LE showed a higher sensitivity and a slightly lower specificity and the same diagnostic accuracy of intraoperative FS. The faster turnaround time (about 20 minutes from receiving of sample by the laboratory), its ease of use and the low costs make this test a valuable alternative to frozen sections and is going to replace FS in our clinical practice.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2018
Zagra L De Vecchi E Bortolin M Romanò C Drago L
Full Access

Reliability of microbiological diagnosis of prosthetic joint infection [PJI] strongly depends on the ability to dislodge microorganisms from biofilm and on the rate of contaminating samples during collection in the operating room and processing. The aim of a correct protocol is to avoid false negative and false positive results in order to adapt the correct therapy for each patient.

The object of the present study was to evaluate the impact of a novel closed bag system designed for samples collection and processing based on dithiothreitol (DTT), which is a sulfydryl compound able to remove bacteria from biofilm (MicroDTTect, 4i, Italy), on isolation of contaminant microorganisms in hip prostheses.

Specimens (prostheses, spacers, periprosthetic tissues) were aseptically collected according to a standard protocol into the device, which was transported to the laboratory for culture. Three different models of the system were prospectively evaluated, each being a development of the previous one. The first generation device consisted in an “open” system (DTT eluate was collected with a syringe and dispensed into sterile tubes), the second generation device in a “partially closed” system (DTT eluate collected directly in sterile vacuum tubes) and the third generation device in a “completely closed system” (DTT reservoir directly connected with sealed tubes inside the device). PJI was diagnosed following criteria established by MSIS.

The overall contamination rate, sensitivity and specificity of the first generation “open” system MicroDTTect were respectively 2.6% (1/39), 82.3% and 95.4% in 39 hips. The second generation “partially closed” device was characterized by a contamination rate of 1.96% (1/51), a sensitivity of 84% and a specificity of 96.1% in 51 hips. Contamination rate further decreased in the third generation “closed” system (1.89%, 2/106), while sensitivity (91.3%) and specificity (96.7%) improved in 106 hips. Differences have been also observed in hips (106) when compared to knees (70 cases) prosthetic infections (sensitivity 91.3% vs 89.3% and specificity 96.7% vs 100%).

Our data show as, thanks to its ease of use, low contamination rate and high sensitivity, MicroDTTect can represent a useful tool for improving the microbiological diagnosis of PJIs in hip revisions and has replaced sonication in our practice.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 28 - 28
1 Dec 2017
Bortolin M Bidossi A Toscano M De Vecchi E Romanò CL Mattina R Drago L
Full Access

Aim

Biofilm-related infections represent a recurrent problem in the orthopaedic setting. In recent years, great interest was directed towards the identification of novel molecules capable to interfere with pathogens adhesion and biofilm formation on implant surfaces. In this study, two stable forms of α-tocopherol, the hydrophobic acetate ester and the water-soluble phosphate ester, were tested in vitro as coating for titanium prostheses.

Method

Antimicrobial activity against microorganisms responsible of prosthetic and joints infections was assessed by broth microdilution method. In addition, α-tocopherol esters were evaluated for both their ability to hamper bacterial adhesion and biofilm formation on sandblasted titanium surfaces.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 104 - 104
1 Dec 2015
De Vecchi E Villa F Agrappi S Toscano M Drago L
Full Access

Culture examination is still considered the gold standard for diagnosis of bone and joint infections, including prosthetic ones, even if in up to 20–30% of cases, particularly prosthetic joint infections, it fails to yield microbial growth. To overcome this limitation, determination of markers of inflammation and or infection directly in joint fluid has been proposed.

Aim of this study was to evaluate the applicability of measurement of lecukocyte esterase (LE), C-reactive protein (CRP) and glucose in synovial fluid for diagnosis of bone and joint infections.

Synovial fluids from 80 patients were aseptically collected and sent to laboratory for microbiological cultures. After centrifugation at 3000 rpm for 10 minutes, pellet was used for cultures, while the surnatant was used for determination of LE, CRP and glucose. LE and glucose were evaluated by means of enzymatic colorimetric strips developed for urinanalysis. One drop of synovial fluid was placed on the LE and on the glucose pads and the results were read after about 120 seconds. A LE test graded + or ++, and a glucose test equal to trace or negative were considered suggestive for infection. CRP was measured by an automated turbidimetric method.

On the basis of clinical findings, microbiological, haematological and histological analyses patients were retrospectively divided into 2 groups. Group 1 comprised 19 infected patients (12 males, 7 females age: 70.6 ± 10.3 yrs, range: 47 – 88 yrs) while Group 2 included 61 aseptic patients (32 males and 29 females, age: 61.5 ± 16.3 yrs, range: 15 – 84). Sensitivity of the three tests was 89.5%. 84% and 73,7% for LE, CRP and glucose, respectively. Specificity was 98.4%, 88.5% and 70% for LE, CRP and glucose, respectively. Positive and negative predictive values were 94.4% and 96.8% for LE, 69.6% and 94.6% for CRP and 77.8% and 89.6% for glucose test. When LE was combined with CRP, sensitivity increased to 94.7%, while no differences were observed for LE combined with glucose.

Leukocyte esterase has proven to be a rapid, simple and inexpensive test to rule in or out bone and joint infections. Combination of its measurement with that of CRP increased sensitivity. In conclusion, the combination of leukocyte esterase and CRP may represent a simple and useful tool for diagnosis of bone and joint infections.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 77 - 77
1 Dec 2015
Toscano M De Vecchi E Drago L
Full Access

The role of biofilm in pathogenesis of several chronic human infections is widely accepted, as this structure leads pathogens to persist among the human body, being protected from the action of antibacterial molecules and drugs (1). It has been estimated that up to 65% of bacterial infections are caused by microorganisms growing in biofilms (2). Moreover, biofilm is involved in device-related orthopaedic bacterial infections, which are unaffected by vaccines and antibiotic therapies, constituting a serious problem for the human health care.

The aim of the present work was to evaluate the anti-biofilm action of a selected and patented lactobacillus strain (MD1) supernatant, both on the in-formation- biofilm and on mature biofilm produced by pathogenic bacteria.

MD1 was grown in BHI for 48 h at 37°C. After incubation, the sample was centrifuged for 5’ for 14,000 × g and the supernatant previously filtered and treated in order to obtain the anti-biofilm compounds (Special Supernatant – SS) was collected. Staphylococcus aureus and Pseudomonas aeruginosa strains were grown in BHI for 24h at 37°C. The anti-biofilm ability of the tested SS – lactobacillus strain was evaluated by a spectrophotometric method according to Christensen at al., following the incubation of pathogens and the “mature biofilm” with the lactobacillus supernatant. Confocal Laser Scanning Microscopy was used to confirm the data obtained from Crystal Violet Assay.

After the incubation of the SS with pathogens and mature biofilm, the formation of biofilm was inhibited and a significant disruption of the mature biofilm was observed. Interestingly, the same properties were observed also when the SS pH was neutralized to pH 6.5. In particular, the reduction of biofilm production and the disruption of mature biofilm was about 50–70% for all microorganisms.

The SS lactobacillus strain MD1 exhibited a relevant antibiofilm action against mature and in-formation-biofilm produced by S. aureus and P. aeruginosa strains tested in the study. Moreover, the antibiofilm action has been observed to be pH-independent, as when the supernatant was neutralized to pH 6.5, the reduction of pathogenic biofilm has been still observed. These promising results highlighted the possibility to use this SS-lactobacillus anti-biofilm property to develop a cost-effective and safety treatment able to reduce the impact of pathogenic biofilm on device-related orthopaedic bacterial infections.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 88 - 88
1 Dec 2015
De Vecchi E Signori V Bortolin M Romanò C Drago L
Full Access

Prosthetic implants, periprosthetic and osteoarticular tissues are specimens of choice for diagnosis of bone and joint infections including prosthetic joint infections (PJIs). However, it is widely known that cultures from prostheses and tissues may fail to yield microbial growth in up to one third of patients. In the recent past, treatment of prosthetic implants have been optimized in order to improve sensitivity of microbiological cultures, while less attention has been addressed to tissue samples. For these latter homogenization is considered the best procedure, but it is quite laborious, time-consuming and it is not always performed in all laboratories. Dithiothreitol (DTT) has been proposed as an alternative treatment to sonication for microbiological diagnosis of PJIs. In this study, we evaluated the applicability of MicroDTTect treatment, a closed system developed for transport and treatment of tissues and prosthetic implants with DTT.

For evaluation of applicability of MicroDTTect to tissue specimens, samples (tissues and, in case of PJI, prosthetic implants) from 40 patients (12 PJIs and 5 osteomyelitis and 23 not-infected) were evaluated. MicroDTTect system consists of a sterile plastic bag containing a reservoir which allows for release of a 0.1% (v:v) DTT solution, once the sample is placed into the bag. Comparison of MicroDTTect treatment of prostheses with sonication included samples from 30 patients (14 with aseptic loosening of the prosthesis and 16 with PJIs). Of two tissue samples from the same region, one was placed into MicroDTTect bag and the other was collected in a sterile container with addition of sterile saline. After agitation and centrifugation of the eluate, aliquots of the pellets were plated on agar plates and inoculated into broths which were incubated for 48 hrs and 15 days, respectively.

Treatment of prosthetic implants with MicroDTTect showed a higher specificity and sensitivity than sonication (specificity 92.8% vs 85.7%; sensitivity: 87.5% vs 75.0 % DTT vs sonication). When used for tissue treatment, MicroDTTect showed a sensitivity of 82.3% and a specificity of 97% which were higher than that observed when saline was used (sensitivity: 64.7%; specificity 91%).

Treatment of tissues and prosthetic implants with MicroDTTect may be a practicable strategy to improve microbiological diagnosis of osteoarticular infections, reducing sample manipulation and therefore limiting sample contamination. Moreover, use of MicroDTTect does not require dedicated instrumentation, and is time and cost saving.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 845 - 850
1 Jun 2014
Romanò CL Logoluso N Meani E Romanò D De Vecchi E Vassena C Drago L

The treatment of chronic osteomyelitis often includes surgical debridement and filling the resultant void with antibiotic-loaded polymethylmethacrylate cement, bone grafts or bone substitutes. Recently, the use of bioactive glass to treat bone defects in infections has been reported in a limited series of patients. However, no direct comparison between this biomaterial and antibiotic-loaded bone substitute has been performed.

In this retrospective study, we compared the safety and efficacy of surgical debridement and local application of the bioactive glass S53P4 in a series of 27 patients affected by chronic osteomyelitis of the long bones (Group A) with two other series, treated respectively with an antibiotic-loaded hydroxyapatite and calcium sulphate compound (Group B; n = 27) or a mixture of tricalcium phosphate and an antibiotic-loaded demineralised bone matrix (Group C; n = 22). Systemic antibiotics were also used in all groups.

After comparable periods of follow-up, the control of infection was similar in the three groups. In particular, 25 out of 27 (92.6%) patients of Group A, 24 out of 27 (88.9%) in Group B and 19 out of 22 (86.3%) in Group C showed no infection recurrence at means of 21.8 (12 to 36), 22.1 (12 to 36) and 21.5 (12 to 36) months follow-up, respectively, while Group A showed a reduced wound complication rate.

Our results show that patients treated with a bioactive glass without local antibiotics achieved similar eradication of infection and less drainage than those treated with two different antibiotic-loaded calcium-based bone substitutes.

Cite this article: Bone Joint J 2014; 96-B:845–50.