header advert
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1662 - 1668
1 Nov 2021
Bhanushali A Chimutengwende-Gordon M Beck M Callary SA Costi K Howie DW Solomon LB

Aims

The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements.

Methods

Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 3 - 3
1 Mar 2021
Chimutengwende-Gordon M Callary S Davidson J Costi K Pannach S Stamenkov R Howie DW Solomon LB
Full Access

Femoral impaction bone grafting (IBG) may be used to restore bone stock in revision total hip arthroplasty (THA) and allow use of a shorter, than otherwise, length prosthesis. This is most beneficial in young patients who are more likely to require further revision surgery. This study aimed to assess the results of femoral IBG for staged revision THA for infection. A prospective cohort of 29 patients who underwent staged revision THA for infection with femoral IBG and a cemented polished double-tapered (CPDT) stem at the final reconstruction was investigated.

The minimum follow-up was two years (2 – 10 years, median 6 years). Stem subsidence was measured with radiostereometric analysis. Clinical outcomes were assessed with the Harris Hip, Harris Pain, and and Société Internationale de Chirurgie Orthopédique et de Traumatologie Activity (SICOT) Scores. The original infection was eradicated in 28 patients. One patient required a repeat staged revision due to re-infection with the same organism. At two-year follow-up, the median subsidence at the stem-bone interface was −1.70 mm (−0.31 to −4.98mm). The median Harris Hip Score improved from 51 pre-operatively to 80 at two years (p=0.000), the Harris Pain Score from 20 to 44 (p=0.000) and the SICOT Score from 2.5 to 3 (p=0.003).

As successful eradication of infection was achieved in the majority of patients and the stem migration was similar to that of a primary CPDT stem, this study supports the use of femoral IBG during the final reconstruction of the femur after staged revision THA for infection.


Aims

The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) may improve quality of life for amputees by avoiding soft-tissue complications associated with socket prostheses and by improving sensory feedback and function. It relies on the formation of a seal between the soft tissues and the implant and currently has a flange with drilled holes to promote dermal attachment. Despite this, infection remains a significant risk. This study explored alternative strategies to enhance soft-tissue integration.

Materials and Methods

The effect of ITAP pins with a fully porous titanium alloy flange with interconnected pores on soft-tissue integration was investigated. The flanges were coated with fibronectin-functionalised hydroxyapatite and silver coatings, which have been shown to have an antibacterial effect, while also promoting viable fibroblast growth in vitro. The ITAP pins were implanted along the length of ovine tibias, and histological assessment was undertaken four weeks post-operatively.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 276 - 282
1 Feb 2017
Mumith A Coathup M Chimutengwende-Gordon M Aston W Briggs T Blunn G

Aims

Massive endoprostheses rely on extra-cortical bone bridging (ECBB) to enhance fixation. The aim of this study was to investigate the role of selective laser sintered (SLS) porous collars in augmenting the osseointegration of these prostheses.

Materials and Methods

The two novel designs of porous SLS collars, one with small pores (Ø700 μm, SP) and one with large pores (Ø1500 μm, LP), were compared in an ovine tibial diaphyseal model. Osseointegration of these collars was compared with that of a clinically used solid, grooved design (G). At six months post-operatively, the ovine tibias were retrieved and underwent radiological and histological analysis.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 67 - 68
1 Jan 2011
Chimutengwende-Gordon M Pendegrass C Blunn G
Full Access

Background: Osseointegrated amputation prostheses avoid soft tissue complications associated with traditional socket prostheses. Forces are transmitted directly to the skeleton resulting in improved function. However, approximately 50% of transcutaneous implants become infected due to the lack of a successful skin-implant seal. Intraosseous Transcutaneous Amputation Prostheses (ITAP) are designed to integrate with the skin preventing epithelial downgrowth and infection.

Fibronectin adsorption enhances fibroblast adhesion in vitro; however, in vivo, fibronectin becomes desorbed from the implant surface. Covalent attachment of fibronectin by silanisation has been shown to be durable in vitro. The silanisation process for fibronectin includes a stage of passivation with sulphuric acid which alters surface characteristics.

Aims: The aim of this study was to determine if in vitro fibroblast adhesion to silanised fibronectin (SiFn) titanium alloy could be improved by omitting or reducing the length of time of passivation. The study also assessed the effects of SiFn on dermal attachment in vivo comparing the results with adsorbed fibronectin substrates and with uncoated controls.

Methods: Scanning electron microscopy, Ra profilometry and contact angle measurement (n=6) were used for topographical characterization of surfaces. Anti-vinculin antibodies were used to immunolocalize fibroblast adhesion sites after 24 hours. The morphology of fibroblasts on each surface was evaluated using scanning electron microscopy. Subcutaneous plates were implanted onto the tibiae of an ovine model (n=3) in order to evaluate the performance of the modified SiFn surface in vivo. Hydroxyapatite (HA) and adsorption of fibronectin to HA (HAFn) were also tested because HA coatings are currently applied to the dermal section of ITAP in clinical trials. After four weeks, a histological assessment of the percentage of soft-tissue attachment and cell alignment relative to the implant was performed.

Results: Passivation produced rougher, more hydrophobic surfaces with numerous microcracks and was associated with poorer fibroblast adhesion and spreading than un-passivated controls in vitro.

SiFn with passivation resulted in poorer cell adhesion than SiFn without passivation. Reducing the time period for passivation did not reduce the detrimental effects of passivation In vivo, HAFn and SiFn resulted in higher median values for soft-tissue attachment than simple adsorption of fibronectin; however, the differences were not statistically significant. Cell alignment was significantly different for HAFn and SiFn compared with controls (p< 0.05), with cells on the fibro-nectin treated surfaces orientated more perpendicular to the implant surface.

Conclusion: Omission of passivation improves fibro-blast adhesion to SiFn surfaces in vitro. Coating with fibronectin either by silanisation onto titanium alloy or by adsorption onto HA surfaces affected the orientation of cells in vivo, implying that tissue attachment was enhanced. A time course may be of value to determine if fibronectin coatings are lost over time in vivo.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1361 - 1363
1 Oct 2005
Hardy JRW Chimutengwende-Gordon M Bakar I

We reviewed the records of 107 consecutive patients who had undergone surgery for disruption of the knee extensor mechanism to test whether an association existed between rupture of the quadriceps tendon and the presence of a patellar spur. The available standard pre-operative lateral radiographs were examined to see if a patellar spur was an indicator for rupture of the quadriceps tendon in this group of patients. Of the 107 patients, 12 underwent repair of a ruptured patellar tendon, 59 had an open reduction and internal fixation of a patellar fracture and 36 repair of a ruptured quadriceps tendon. In the 88 available lateral radiographs, patellar spurs were present significantly more commonly (p < 0.0005) in patients operated on for rupture of the quadriceps tendon (79%) than in patients with rupture of the patellar tendon (27%) or fracture of the patella (15%). In patients presenting with failure of the extensor mechanism of the knee in the presence of a patellar spur, rupture of the quadriceps tendon should be considered as a possible diagnosis.