header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 9 - 9
1 Apr 2019
Cavagnaro L Burastero G Chiarlone F Felli L
Full Access

Introduction

Bone loss management represents one of the most challenging issues for the orthopaedic surgeon. In most cases, stems, structural allograft, TMcones, and sleeves are adequate to allow optimal implant stability and durable fixation. In selected cases of wide metadiaphyseal bone defects, these devices do not provide proper intraoperative stability. In such scenarios, further steps are needed and include complex modular reconstruction, substitution with megaprosthesis (exposing patients at high risk of early failure) or joint arthrodesis that can yield unacceptable results. The aim of this paper is to present early results obtained with a new custom-made implant for complex metadiaphyseal bone defects management in knee revision surgery. By means of case presentations the authors would highlight the possibilities and technical notes of this novel device in complex knee revision surgery.

Methods

Since2015, 8 custom-made porous titanium devices were implanted for massive bone defect management in 6 knee arthroplasty revision procedures. Five patients were staged revision for periprosthetic joint infection (PJI) and one patient underwent a staged revision for post-traumatic septic arthritis. Main demographic and surgical data were collected. Clinical (Range of Movement [ROM], Knee Society Score [KSS] and Oxford Knee Score [OKS]), radiological findings and complications were recorded at different time points and statistically evaluated. Mean follow up was 19.5 ± 9.6months.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 46 - 46
1 Dec 2017
Burastero G Cavagnaro L Chiarlone F Riccio G Felli L
Full Access

Aim

Femoral or tibial massive bone defects (AORI F2B-F3 / T2B-T3) are common in septic total knee replacement. Different surgical techniques are described in literature. In our study we show clinical and radiological results associated with the use of tantalum metaphyseal cones in the management of cavitary bone defects in two-stage complex knee revision.

Method

Since 2010 we have implanted 70 tantalum metaphyseal cones associated with constrained or semiconstrained knee prostheses in 47 patients. The indication for revision was periprosthetic knee infection (43 cases, 91.5%) or septic knee arthritis (4 patients, 8.5%) with massive bone defect. All cases underwent a two-stage procedure. Patients were screened for main demographic and surgical data. Clinical and radiological analysis was performed in the preoperative and at 3,6 months, 1 years and each year thereafter in the postoperative. The mean follow-up was 31.1 months ± 18.8. No dropout was observed.