Abstract

Aim

Femoral or tibial massive bone defects (AORI F2B-F3 / T2B-T3) are common in septic total knee replacement. Different surgical techniques are described in literature. In our study we show clinical and radiological results associated with the use of tantalum metaphyseal cones in the management of cavitary bone defects in two-stage complex knee revision.

Method

Since 2010 we have implanted 70 tantalum metaphyseal cones associated with constrained or semiconstrained knee prostheses in 47 patients. The indication for revision was periprosthetic knee infection (43 cases, 91.5%) or septic knee arthritis (4 patients, 8.5%) with massive bone defect. All cases underwent a two-stage procedure. Patients were screened for main demographic and surgical data. Clinical and radiological analysis was performed in the preoperative and at 3,6 months, 1 years and each year thereafter in the postoperative. The mean follow-up was 31.1 months ± 18.8. No dropout was observed.

Results

Objective and subjective functional scores (KSS, OKS) showed a statistically significant improvement from the preoperative to last follow-up (p <0.001). All cones but one (98.6%) showed radiological osteointegration. We did not find any cone-related intraoperative or postoperative mechanical complication with a 100% survival rate when we consider aseptic loosening as cause of revision. Six non progressive radiolucencies were observed. Two septic failures (4.3%) with implant and cone removal were reported.

Conclusions

The ideal treatment for cavitary bone defects in two-stage TKA septic revision is still unclear. The use of metaphyseal tantalum cones showed excellent clinical and radiographic results with a low rate of related complications. The main finding of our study is the cone-related infection rate (2.9%) in this particular series of patients. This data is comparable or better than other previous report about this topic with unhomogeneous cohort of patients.