header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 90 - 90
1 Nov 2021
Kowalski E Catelli D Lamontagne M Dervin G
Full Access

Introduction and Objective

Gait variability is the amplitude of the fluctuations in the time series with respect to the mean of kinematic (e.g., joint angles) or kinetic (e.g., joint moments) measurements. Although gait variability increases with normal ageing or pathological mechanisms, such as knee osteoarthritis (OA). The purpose was to determine if a patient who underwent a total knee arthroplasty (TKA) can reduce gait variability.

Materials and Methods

Twenty-five patients awaiting TKA were randomly assigned to receive either medial pivot (MP, m=7/f=6, age=62.4±6.2 years) or posterior stabilized (PS, m=7/f=5, age=63.7±8.9 years) implants, and were compared to 13 controls (CTRL, m=7/f=6, age=63.9±4.3 years). All patients completed a gait analysis within one month prior and 12 months following surgery, CTRLs completed the protocol once. A waveform F-Test Method (WFM) was used to compare the variance in knee biomechanics variables at each interval of the gait cycle.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 47 - 47
1 Feb 2021
Catelli D Grammatopoulos G Cotter B Mazuchi F Beaule P Lamontagne M
Full Access

Introduction

Interactions between hip, pelvis and spine, as abnormal spinopelvic movements, have been associated with inferior outcomes following total hip arthroplasty (THA). Changes in pelvis position lead to a mutual change in functional cup orientation, with both pelvic tilt and rotation having a significant effect on version. Hip osteoarthritis (OA) patients have shown reduced hip kinematics which may place increased demands on the pelvis and the spine.

Sagittal and coronal planes assessments are commonly done as these can be adequately studied with anteroposterior and lateral radiographs. However, abnormal pelvis rotation is likely to compromise the outcome as they have a detrimental effect on cup orientation and increased impingement risk. This study aims to determine the association between dynamic motion and radiographic sagittal assessments; and examine the association between axial and sagittal spinal and pelvic kinematics between hip OA patients and healthy controls (CTRL).

Methods

This is a prospective study, IRB approved. Twenty hip OA pre-THA patients (11F/9M, 67±9 years) and six CTRL (3F/3M, 46±18 years) underwent lateral spinopelvic radiographs in standing and seated bend-and-reach (SBR) positions. Pelvic tilt (PT), pelvic-femoral-angle (PFA) and lumbar lordosis (LL) angles were measured in both positions and the differences (Δ) between standing and SBR were calculated. Dynamic SBR and seated maximal-trunk-rotation (STR) were recorded in the biomechanics laboratory using a 10-infrared camera and processed on a motion capture system (Vicon, UK). Direct kinematics extracted maximal pelvic tilt (PTmax), hip flexion (HFmax) and (mid-thoracic to lumbar) spinal flexion (SFmax). The SBR pelvic movement contribution (ΔPTrel) was calculated as ΔPT/(ΔPT+ΔPFA)∗100 for the radiographic analysis and as PTmax/(PTmax+HFmax) for the motion analyses. Axial and sagittal, pelvic and spinal range of motion (ROM) were calculated for STR and SBR, respectively. Spearman's rank-order determined correlations between the spinopelvic radiographs and sagittal kinematics, and the sagittal/axial kinematics. Mann-Whitney U-tests compared measures between groups.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 109 - 109
1 Jul 2020
Kowalski E Lamontagne M Catelli D Beaulé P
Full Access

The literature indicates that femoroacetabular impingement (FAI) patients do not return to the level of controls (CTRL) following surgery. The purpose of this study was to compare hip biomechanics during stair climbing tasks in FAI patients before and two years after undergoing corrective surgery against healthy controls (CTRL).

A total of 27 participants were included in this study. All participants underwent CT imaging at the local hospital, followed by three-dimensional motion analysis done at the human motion biomechanics laboratory at the local university. Participants who presented a cam deformity >50.5° in the oblique-axial or >60° in the radial planes, respectively, and who had a positive impingement test were placed in the FAI group (n=11, age=34.1±7.4 years, BMI=25.4±2.7 kg/m2). The remaining participants had no cam deformity and negative impingement test and were placed in the CTRL group (n=16, age=33.2±6.4 years, BMI=26.3±3.2 kg/m2). The CTRL group completed the biomechanics protocol once, whereas the FAI group completed the protocol twice, once prior to undergoing corrective surgery for the cam FAI, and the second time at approximately two years following surgery.

At the human motion biomechanics laboratory, participants were outfitted with 45 retroreflective markers placed according to the UOMAM marker set. Participants completed five trials of stairs task on a three step instrumented stair case to measure ground reaction forces while 10 Vicon MX-13 cameras recorded the marker trajectories. Data was processed using Nexus software and divided into stair ascent and stair descent tasks. The trials were imported into custom written MatLab software to extract peak pelvis and hip kinematics and hip kinetic variables. Non-parametric Kruskal-Wallis tests were used to determine significant (p < 0.05) differences between the groups.

No significant differences occurred during the stair descent task between any of the groups. During the stair ascent task, the CTRL group had significantly greater peak hip flexion angle (Pre-Op=58±7.1°, Post-Op=58.1±6.6°, CTRL=64.1±5.1°) and sagittal hip range of motion (ROM) (Pre-Op=56.7±6.7°, Post-Op=56.3±5.5°, CTRL=61.7±4.2°) than both the pre- and post-operative groups. Pre-operatively, the FAI group had significantly less peak hip adduction angle (Pre-Op=2±4.5°, Post-Op=3.4±4.4°, CTRL=5.5±3.7°) and hip frontal ROM (Pre-Op=9.9±3.4°, Post-Op=11.9±5.4°, CTRL=13.4±2.5°) compared to the CTRL group. No significant differences occurred in the kinetic variables.

Our findings are in line with the Rylander and colleagues (2013) who also found that hip sagittal ROM did not improve following corrective surgery. Their study included a mix of cam and pincer-type FAI, and had a mean follow-up of approximately one year. Our cohort included only cam FAI and they had a mean follow-up of approximately two years, indicating with the extra year, the patients still did not show sagittal hip kinematics improvement. In the frontal plane, there was no significant difference between the post-op and the CTRL, indicating that the postoperative FAI reached the level of the CTRLs. This is in line with recent work that indicates a more medialized hip contact force vector following surgery, suggesting better hip stabilization.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 117 - 117
1 Nov 2018
Catelli D Ng K Kowalski E Beaulé P Lamontagne M
Full Access

Cam-type femoroacetabular impingement (FAI) is a common cause for athletic hip injury and early hip osteoarthritis. Although corrective cam FAI surgery can improve patient reported outcome measures (PROMs), it is not clear how surgery affects muscle forces and hip joint loading. Surgery for FAI may redistribute muscle forces and contact forces at the hip joint during routine activities. The purpose of this study was to examine the muscle contributions and hip contact forces during gait in patients prior and after two years of undergoing surgery for cam FAI. Kinematics and kinetics were recorded in 11 patients with symptomatic cam FAI as they completed a gait task. Muscle and hip contact forces during the stance phase were estimated using musculoskeletal modelling and static optimization in OpenSim. All patients reported improvements in PROMs. Post-operatively, patients showed reduced forces in the long head of the biceps femoris at ipsilateral foot-strike and in the rectus femoris at the contralateral foot-strike. The reduced muscle forces decreased sagittal hip moment but did not change hip contact forces. This was the first study to evaluate hip muscle and contact forces in FAI patients post-operatively. Although hip contact forces are not altered following surgery, muscle forces are decreased even after two years. These findings can provide guidance in optimizing recovery protocols after FAI surgery to improve hip flexor and extensor muscle forces.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 4 - 4
1 Jan 2017
Lamontagne M Kowalski E Catelli D Beaulé P
Full Access

Dual mobility (DM) bearing implants reduce the incidence of dislocation following total hip arthroplasty (THA) and as such they are used for the treatment of hip instability in both primary and revision cases. The aim of this study was to compare lower limb muscle activity of patients who underwent a total hip arthroplasty (THA) with a dual mobility (DM) or a common cup (CC) bearing compared to healthy controls (CON) during a sit to stand task.

A total of 21 patients (12 DM, 9 CC) and 12 CON were recruited from the local Hospital. The patients who volunteered for the study were randomly assigned to either a DM or a CC cementless THA after receiving informed consent. All surgeries were performed by the same surgeon using the direct anterior approach. Participants underwent electromyography (EMG) and motion analysis while completing a sit-to-stand task. Portable wireless surface EMG probes were placed on the vastus lateralis, rectus femoris, biceps femoris, semitendinosus (ST), gluteus medius and tensor fasciae latae muscles of the affected limb in the surgical groups and the dominant limb in the CON group. Motion capture was used to record lower limb kinematics and kinetics. Muscle strength was recorded using a hand-held dynamometer during maximal voluntary isometric contraction (MVIC) testing. Peak linear envelope (peakLE) and total muscle activity (iEMG) were extrapolated and normalized to the MVIC and time cycle for the sit to stand task. Using iEMG, quadriceps-hamstrings muscle co-activation index was calculated for the task. Nonparametric Kruskal Wallace ANOVA tests and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred.

The DM group had greater iEMG of the ST muscle compared to the CC (p=0.045) and the CON (p=0.015) groups. The CC group had lower iEMG for hamstring muscles compared to the DM (p=0.041) group. The DM group showed lower quadriceps-hamstrings co-activation index compared to the CON group and it approached significance (p=0.054). The CC group had greater anterior pelvis tilt compared to both DM (p=0.043) and the CON (p=0.047) groups. The DM also had larger knee varus angles and less knee internal rotation compared to both groups, however this never reached significance. No significant differences in muscle strength existed between the groups.

Higher ST muscle activity in the DM group is explained by the reduction in internal rotation at the knee joint as the ST muscle was more active to resist the varus forces during the sit-to-stand task. Reduced quadriceps activity in the CC group is explained by increased pelvic anterior tilt as this would shorten the moment arm and muscle length in the quadriceps, ultimately reducing quadriceps muscle activity. The reduced co-activation between quadriceps and hamstrings activity in the DM group compared to the CC and CON groups is related to better hip function and stability. Combining lower co-activation and larger range of motion for the DM group without impingement, this implant seems to offer better prevention against THA subluxation and less wear of the implant.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 51 - 51
1 Nov 2016
Lamontagne M Ng G Catelli D Beaulé P
Full Access

With the growing number of individuals with asymptomatic cam-type deformities, elevated alpha angles alone do not always explain clinical signs of femoroacetabular impingement (FAI). Differences in additional anatomical parameters may affect hip joint mechanics, altering the pathomechanical process resulting in symptomatic FAI. The purpose was to examine the association between anatomical hip joint parameters and kinematics and kinetics variables, during level walking.

Fifty participants (m = 46, f = 4; age = 34 ± 7 years; BMI = 26 ± 4 kg/m²) underwent CT imaging and were diagnosed as either: symptomatic (15), if they showed a cam deformity and clinical signs; asymptomatic (19), if they showed a cam deformity, but no clinical signs; or control (16), if they showed no cam deformity and no clinical signs. Each participant's CT data was measured for: axial and radial alpha angles, femoral head-neck offset, femoral neck-shaft angle, medial proximal femoral angle, femoral torsion, acetabular version, and centre-edge angle. Participants performed level walking trials, which were recorded using a ten-camera motion capture system (Vicon MX-13, Oxford, UK) and two force plates (Bertec FP4060–08, Columbus, OH, USA). Peak sagittal and frontal hip joint angles, range of motion, and moments were calculated using a custom programming script (MATLAB R2015b, Natick, MA, USA). A one-way, between groups ANOVA examined differences among kinematics and kinetics variables (α = 0.05), using statistics software (IBM SPSS v.23, Armonk, NY, USA); while a stepwise multiple regression analysis examined associations between anatomical parameters and kinematics and kinetics variables.

No significant differences in kinematics were observed between groups. The symptomatic group demonstrated lower peak hip abduction moments (0.12 ± 0.08 Nm/kg) than the control group (0.22 ± 0.10 Nm/kg, p = 0.01). Sagittal hip range of motion showed a moderate, negative correlation with radial alpha angle (r = −0.33, p = 0.02), while peak hip abduction moment correlated with femoral neck-shaft angle (r = 0.36, p = 0.009) and negatively with femoral torsion (r = −0.36, p = 0.009). With peak hip abduction moment in the stepwise regression analysis, femoral torsion accounted for a variance of 13.3% (F(1, 48) = 7.38; p = 0.009), while together with femoral neck-shaft angle accounted for a total variance of 20.4% (R² change = 0.07, F(2, 47) = 6.01; p = 0.047).

Although elevated radial alpha angles may have limited sagittal range of motion, the cam deformity parameters did not affect joint moments. Femoral neck-shaft angle and femoral torsion were significantly associated with peak hip abduction moment, suggesting that the insertion location of the abductor affects muscle's length and its resultant force vector. A varus neck angle, combined with severe femoral torsion, may ultimately influence muscle moment arms and hip mechanics in individuals with cam FAI.