header advert
Results 1 - 34 of 34
Results per page:
Bone & Joint Open
Vol. 2, Issue 6 | Pages 371 - 379
15 Jun 2021
Davies B Kaila R Andritsos L Gray Stephens C Blunn GW Gerrand C Gikas P Johnston A

Aims

Hydroxyapatite (HA)-coated collars have been shown to reduce aseptic loosening of massive endoprostheses following primary surgery. Limited information exists about their effectiveness in revision surgery. The aim of this study was to radiologically assess osteointegration to HA-coated collars of cemented massive endoprostheses following revision surgery.

Methods

Retrospective review of osseointegration frequency, pattern, and timing to a specific HA-coated collar on massive endoprostheses used in revision surgery at our tertiary referral centre between 2010 to 2017 was undertaken. Osseointegration was radiologically classified on cases with a minimum follow-up of six months.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 134 - 142
1 Feb 2018
Hexter AT Hislop SM Blunn GW Liddle AD

Aims

Periprosthetic joint infection (PJI) is a serious complication of total hip arthroplasty (THA). Different bearing surface materials have different surface properties and it has been suggested that the choice of bearing surface may influence the risk of PJI after THA. The objective of this meta-analysis was to compare the rate of PJI between metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and ceramic-on-ceramic (CoC) bearings.

Patients and Methods

Electronic databases (Medline, Embase, Cochrane library, Web of Science, and Cumulative Index of Nursing and Allied Health Literature) were searched for comparative randomized and observational studies that reported the incidence of PJI for different bearing surfaces. Two investigators independently reviewed studies for eligibility, evaluated risk of bias, and performed data extraction. Meta-analysis was performed using the Mantel–Haenzel method and random-effects model in accordance with methods of the Cochrane group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 9 - 9
1 Oct 2016
Cheong VS Coathup MJ Mumith A Fromme P Blunn GW
Full Access

Long-term survival of massive prostheses used to treat bone cancers is associated with extra-cortical bone growth and osteointegration into a grooved hydroxyapatite coated collar positioned adjacent to the transection site on the implant shaft [1]. The survivorship at 10 years reduces from 98% to 75% where osteointegration of the shaft does not occur. Although current finite element (FE) methods successfully model bone adaption, optimisation of adventitious new bone growth and osteointegration is difficult to predict. There is thus a need to improve existing FE models by including biological processes of osteoconduction and osteoinduction.

The principal bone adaptation criteria is based on the standard strain-energy remodeling algorithm, where the rate of remodeling is controlled by the difference in the stimulus against the reference value [3]. The additional concept of bone connectivity was introduced, to limit bone growth to neighbouring elements (cells) adjoining existing bone elements. The algorithm was developed on a cylindrical model before it was used on an ovine model.

The geometry and material properties from two ovine tibiae were obtained from computed tomography (CT) scans and used to develop FE models of the tibiae implanted with a grooved collar. The bones were assigned inhomogeneous material properties based on the CT grey values and typical ovine walking load conditions were applied. The FE results show a region of bone tissue growth below the implanted collar and a small amount of osteointegration with the implant, which is in good agreement to clinical results. Some histological results suggest that further bone growth is possible and potential improvements to the model will be discussed. In summary, by including an algorithm that describes osteoconduction, adventitious bone growth can be predicted.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 917 - 924
1 Jul 2016
Whittaker RK Hothi HS Meswania JM Berber R Blunn GW Skinner JA Hart AJ

Aims

Surgeons have commonly used modular femoral heads and stems from different manufacturers, although this is not recommended by orthopaedic companies due to the different manufacturing processes.

We compared the rate of corrosion and rate of wear at the trunnion/head taper junction in two groups of retrieved hips; those with mixed manufacturers (MM) and those from the same manufacturer (SM).

Materials and Methods

We identified 151 retrieved hips with large-diameter cobalt-chromium heads; 51 of two designs that had been paired with stems from different manufacturers (MM) and 100 of seven designs paired with stems from the same manufacturer (SM). We determined the severity of corrosion with the Goldberg corrosion score and the volume of material loss at the head/stem junction. We used multivariable statistical analysis to determine if there was a significant difference between the two groups.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 504 - 511
1 Apr 2016
Ajami S Blunn GW Lambert S Alexander S Foxall Smith M Coathup MJ

Aims

To assess the extent of osteointegration in two designs of shoulder resurfacing implants. Bony integration to the Copeland cylindrical central stem design and the Epoca RH conical-crown design were compared.

Patients and Methods

Implants retrieved from six patients in each group were pair-matched. Mean time to revision surgery of Copeland implants was 37 months (standard deviation (sd) 23; 14 to 72) and Epoca RH 38 months (sd 28; 12 to 84). The mean age of patients investigated was 66 years (sd 4; 59 to 71) and 58 years (sd 17; 31 to 73) in the Copeland and Epoca RH groups respectively. None of these implants were revised for loosening.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1183 - 1191
1 Sep 2015
Briggs TWR Hanna SA Kayani B Tai S Pollock RC Cannon SR Blunn GW Carrington RWJ

The long term biological effects of wear products following total hip arthroplasty (THA) are unclear. However, the indications for THA are expanding, with increasingly younger patients undergoing the procedure.

This prospective, randomised study compared two groups of patients undergoing THA after being randomised to receive one of two different bearing surfaces: metal-on-polyethylene (MoP) n = 22 and metal-on-metal (MoM) n = 23. We investigated the relationship between three variables: bearing surface (MoP vs MoM), whole blood levels of chromium (Cr) and cobalt (Co) and chromosomal aberrations in peripheral lymphocyte pre-operatively and at one, two and five years post-surgery.

Our results demonstrated significantly higher mean cobalt and chromium (Co and Cr) blood levels in the MoM group at all follow-up points following surgery (p < 0.01), but there were no significant differences in the chromosomal aberration indices between MoM and MoP at two or five years (two years: p = 0.56, p = 0.08, p = 0.91, p = 0.51 and five years: p = 0.086, p = 0.73, p = 0.06, p = 0.34) for translocations, breaks, loss and gain of chromosomes respectively. Regression analysis showed a strong linear relationship between Cr levels and the total chromosomal aberration indices in the MoM group (R2 = 0.90016), but this was not as strong for Co (R2 = 0.68991). In the MoP group, the analysis revealed a poor relationship between Cr levels and the total chromosomal aberration indices (R2 = 0.23908) but a slightly stronger relationship for Co (R2 = 0.64292). Across both groups, Spearman’s correlation detected no overall association between Co and Cr levels and each of the studied chromosomal aberrations. There remains no clear indication which THA bearing couple is the most biocompatible, especially in young active patients. While THA continues to be very successful at alleviating pain and restoring function, the long-term biological implications of the procedure still require further scrutiny.

Cite this article: Bone Joint J 2015;97-B:1183–91.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 263 - 269
1 Feb 2014
Batta V Coathup MJ Parratt MT Pollock RC Aston WJ Cannon SR Skinner JA Briggs TW Blunn GW

We reviewed the outcome of 69 uncemented, custom-made, distal femoral endoprosthetic replacements performed in 69 patients between 1994 and 2006. There were 31 women and 38 men with a mean age at implantation of 16.5 years (5 to 37). All procedures were performed for primary malignant bone tumours of the distal femur. At a mean follow-up of 124.2 months (4 to 212), 53 patients were alive, with one patient lost to follow-up. All nine implants (13.0%) were revised due to aseptic loosening at a mean of 52 months (8 to 91); three implants (4.3%) were revised due to fracture of the shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic fracture. Bone remodelling associated with periosteal cortical thinning adjacent to the uncemented intramedullary stem was seen in 24 patients but this did not predispose to failure. All aseptically loose implants in this series were diagnosed to be loose within the first five years.

The results from this study suggest that custom-made uncemented distal femur replacements have a higher rate of aseptic loosening compared to published results for this design when used with cemented fixation. Loosening of uncemented replacements occurs early indicating that initial fixation of the implant is crucial.

Cite this article: Bone Joint J 2014;96-B:263–9.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 78 - 78
1 Dec 2013
Hothi H Cro S Bills P Blunt L Racasan R Blunn GW Skinner JA Hart A
Full Access

Introduction

Metal-on-metal (MOM) total hip arthroplasty using large diameter femoral heads offer clinical advantages however the failure rates of these hips is unacceptably high. Retrieved hips have a wide range of wear rates of their bearing and taper surfaces and there is no agreement regarding the cause of failure.

Detailed visual inspection is the first step in the forensic examination of failed hip components and may help explain the mechanisms of failure. The aim of this study was to determine if there was a correlation between the results of detailed inspections and the volumetric wear of the bearing and taper surfaces of retrieved hips.

Method

Detailed, non-destructive macroscopic and stereomicroscopic examinations of 89 retrieved MOM hip components were performed by a single experienced examiner using quantitative assessment to document the severity of 10 established damage features:

Light scratches, Moderate scratches, Heavy scratches, Embedded particles, Discolouration, Haziness, Pitting, Visible wear zone, Corrosion, Fretting

Each surface was considered in terms of zones comprising of quadrants (cup, head, and taper) and subquadrants (cup and head), Figure 1. Each zone was scored on a scale of 0 to 3 by determining the percentage of the surface area of the zone that exhibited the feature in question: a score of 0=0%, 1<25%, 25%<2<75%, 3>75%. The sum of the scores of each zone was used for the assessment of each damage feature.

The volume of wear at the surfaces of each hip was measured with a Zeiss Prismo coordinate measuring machine (cup and head) and a Talyrond 365 roundness measurement instrument (taper), using previously reported methods1, 2.

Simple linear regression models were used to asses the univariable associations between the inspection scores and wear volumes. Multiple linear regression models were subsequently used to asses the simultaneous contribution of the inspection scores, found significant in univariable analyses, on the wear outcome variables.

All statistical analysis was performed using Stata/IC version 12.1 (StataCorp, USA) and throughout a p value < 0.05 was considered statistically significant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 43 - 43
1 Mar 2013
Dowling RP Pendegrass CJ Blunn GW
Full Access

To try and aid the formation of a soft tissue seal to promote dermal and epidermal attachment to Intraosseous Transcutaneous Amputation Prostheses we compared the effect of titanium surfaces functionalised with fibronectin (fn) or YRGD peptide sequences on human dermal cell (HDF) attachment. We hypothesise that YRGD and fn coatings will significantly increase HDF attachment to titanium alloy substrates. Titanium alloy 10mm discs were polished and acted as control substrates, functionalised surfaces had YRGD or fn adsorbed or silanised onto the polished surface. HDFs were seeded at 10,000/disc and cultured for 1, 4, 24 and 96 hours, fixed and fluorescent immnolocalisation for vinculin was performed. Individual vinculin markers were counted and density calculated as a measure of cell attachment. All assays were performed in triplicate and data were analysed in SPSS 19.0 and results were considered significant at the 0.05 level. Results showed an up-regulation of Focal adhesion density (FA) against controls at all time-points (excluding ad-fn at 4 hours, p=0.057), p values < 0.05, the use of functionalised titanium surfaces may lead to long-term clinical success of ITAP. We have shown a significant positive effect on cell attachment when a synthetic peptide sequence is used. Using synthetic peptide sequence may also be more beneficial from a regulatory stand-point compared with using isolated proteins.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 564 - 569
1 Apr 2012
Pendegrass CJ El-Husseiny M Blunn GW

The success of long-term transcutaneous implants depends on dermal attachment to prevent downgrowth of the epithelium and infection. Hydroxyapatite (HA) coatings and fibronectin (Fn) have independently been shown to regulate fibroblast activity and improve attachment. In an attempt to enhance this phenomenon we adsorbed Fn onto HA-coated substrates. Our study was designed to test the hypothesis that adsorption of Fn onto HA produces a surface that will increase the attachment of dermal fibroblasts better than HA alone or titanium alloy controls.

Iodinated Fn was used to investigate the durability of the protein coating and a bioassay using human dermal fibroblasts was performed to assess the effects of the coating on cell attachment. Cell attachment data were compared with those for HA alone and titanium alloy controls at one, four and 24 hours. Protein attachment peaked within one hour of incubation and the maximum binding efficiency was achieved with an initial droplet of 1000 ng. We showed that after 24 hours one-fifth of the initial Fn coating remained on the substrates, and this resulted in a significant, three-, four-, and sevenfold increase in dermal fibroblast attachment strength compared to uncoated controls at one, four and 24 hours, respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 425 - 430
1 Mar 2012
Picardo NE Blunn GW Shekkeris AS Meswania J Aston WJ Pollock RC Skinner JA Cannon SR Briggs TW

In skeletally immature patients, resection of bone tumours and reconstruction of the lower limb often results in leg-length discrepancy. The Stanmore non-invasive extendible endoprosthesis, which uses electromagnetic induction, allows post-operative lengthening without anaesthesia. Between 2002 and 2009, 55 children with a mean age of 11.4 years (5 to 16) underwent reconstruction with this prosthesis; ten patients (18.2%) died of disseminated disease and one child underwent amputation due to infection. We reviewed 44 patients after a mean follow-up of 41.2 months (22 to 104). The mean Musculoskeletal Tumor Society score was 24.7 (8 to 30) and the Toronto Extremity Salvage score was 92.3% (55.2% to 99.0%). There was no local recurrence of tumour. Complications developed in 16 patients (29.1%) and ten (18.2%) underwent revision.

The mean length gained per patient was 38.6 mm (3.5 to 161.5), requiring a mean of 11.3 extensions (1 to 40), and ten component exchanges were performed in nine patients (16.4%) after attaining the maximum lengthening capacity of the implant. There were 11 patients (20%) who were skeletally mature at follow-up, ten of whom had equal leg lengths and nine had a full range of movement of the hip and knee.

This is the largest reported series using non-invasive extendible endoprostheses after excision of primary bone tumours in skeletally immature patients. The technique produces a good functional outcome, with prevention of limb-length discrepancy at skeletal maturity.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 95 - 95
1 Mar 2012
Wilding CP Maruthainar K Malikian R Stammers J Blunn GW
Full Access

Purpose

To determine the effect that Titanium Nitride (TiN) coatings have on wear rates of ultra high molecular weight polyethylene (UHMWPE)

Background

Ceramic coatings have been shown to confer advantageous countersurface scratch resistance in knee arthroplasty. This may reduce UHMWPE wear rates and revision rates. Dermal hypersensitivity is a common problem with metals; TiN, a ceramic surface, has been used to prevent it. There is little data in the literature regarding the effect of TiN on UHMWPE.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1111 - 1117
1 Aug 2011
Sewell MD Hanna SA McGrath A Aston WJS Blunn GW Pollock RC Skinner JA Cannon SR Briggs TWR

The best method of reconstruction after resection of malignant tumours of the tibial diaphysis is unknown. In the absence of any long-term studies analysing the results of intercalary endoprosthetic replacement, we present a retrospective review of 18 patients who underwent limb salvage using a tibial diaphyseal endoprosthetic replacement following excision of a malignant bone tumour. There were ten men and eight women with a mean age of 42.5 years (16 to 76). Mean follow-up was 58.5 months (20 to 141) for all patients and 69.3 months (20 to 141) for the 12 patients still alive. Cumulative patient survival was 59% (95% confidence interval (CI) 32 to 84) at five years. Implant survival was 63% (95% CI 35 to 90) at ten years. Four patients required revision to a proximal tibial replacement at a mean follow-up of 29 months (10 to 54). Complications included metastases in five patients, aseptic loosening in four, peri-prosthetic fracture in two, infection in one and local recurrence in one. The mean Musculoskeletal Tumor Society score and the mean Toronto Extremity Salvage Score were 23 (17 to 28) and 74% (53 to 91), respectively.

Although rates of complication and revision were high, custom-made tibial diaphyseal replacement following resection of malignant bone tumours enables early return to function and provides an attractive alternative to other surgical options, without apparent compromise of patient survival.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 75 - 75
1 Jan 2011
Parratt MTR Miles J Gokaraju K Spiegelberg BGI Pollock RC Skinner JA Cannon SR Briggs TWR Blunn GW
Full Access

Introduction: Intramedullary cementless fixation of massive tumor prostheses was developed to combat the high incidence of aseptic loosening in a young population of tumor patients. Its use has also expanded to include reconstruction of failed major knee arthroplasty. Our system uses a hydroxyapatite coated titanium stem in conjunction with a hydroxyapatite collar to obtain fixation.

Methods: We present a series of 72 patients (34 females, 38 males) with a mean follow-up of six years (2 months – 14 years). The mean age at the time of surgery was 17 (5 – 77). Within this group, 51 patients had osteosarcomas, 10 had giant cell tumors, eight had Ewing’s sarcoma and one each had malignant fibrous histiocytoma, spindle cell sarcoma and failed total knee arthroplasty. Non-invasive and minimally invasive growing prostheses were used in 33 patients.

Results: Nine patients required revision of the prosthesis at a mean of 5.2 years; 5 for aseptic loosening and four for infection. Twelve patients died at a mean of 20 months (1 – 84) post-operatively. Radiological evidence demonstrated remodelling around both the stem and the collar. There was gap closure to the hydroxyapatite coated collar in cases where seating was not complete. Consistent loss of cortical bone around the mid-stem was noted in the first 12 months but remained stable beyond this time frame.

Discussion: This study highlights our experience with cementless distal femoral endosprostheses. We demonstrate good results with regard to revision rate, gap closure and osseointegration.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 75 - 76
1 Jan 2011
Gokaraju K Miles J Blunn GW Pollock RC Skinner JAM Cannon SR Briggs TWR
Full Access

Introduction: Non-invasive expandable prostheses for limb salvage tumour surgery was first used in 2002 and has now been implanted in a series of 40 skeletally immature patients.

Method: Our review of these includes 24 distal femoral replacements, 5 proximal femoral replacements, 3 total femoral replacements and 8 proximal tibial replacements. These were used to treat 31 osteosarcomas, 7 Ewing’s sarcomas, 1 chondrosarcoma and 1 aneurysmal bone cyst. Patients had a mean age of 11.7 years (7–16). Follow-up extended to 88 months with a mean of 26.3 months.

Results: There has been 1 failure of the prosthesis gearbox which required revision surgery. 4 of the prostheses reached their maximum length and were successfully re-operated to exchange components of the prosthesis and resume lengthening. 3 patients had disseminated meta-static disease (1 being present before primary surgery) and another developed infection of the prosthesis that required an above-knee amputation. There have been 233 lengthenings overall with 1 patient requiring reversal on one occasion due to intractable pain; this pain rescinded 30 minutes after lengthening was reduced by 10mm. Otherwise lengthening was well tolerated despite the significant growth of the limbs: mean 21.2mm (0.5–84mm). At latest follow-up the mean Musculoskeletal Tumour Society score was 75% (26–93%).

Discussion: The results achieved are equivalent to our series of minimally invasive growers which require repeated surgery. Our non-invasive growing prostheses remain reliable and negate the need for recurrent operations, thus resulting in low infection rates. Our results remain encouraging up to 7 years after first use, maintaining leg-length equality and function.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 80 - 81
1 Jan 2011
Gokaraju K Parratt MTR Spiegelberg BGI Miles J Cannon SR Briggs TWR Blunn GW
Full Access

Introduction: Following resection of tumours in the distal femur, reconstruction with joint-sparing prostheses have shown good short-term functional outcomes. There is however limited literature on the affect of knee-sparing prostheses on function of the femoral physes in skeletally immature children.

Method: We discuss two patients, a male (11yrs) and female (10yrs) who had joint-sparing distal femoral prostheses inserted for treatment of Ewing’s sarcoma. The knee joint, along with the distal growth plate, was preserved and fixed to the distal end of the prosthesis using unicortical screws positioned distal to the physis. In the female, these screws were removed 6 months post-op due to prominence of the screws under the skin. In both patients, we assessed radiographs from immediately post-surgery and the most recent follow-up (20 and 28 months respectively). In each set, for the operated limb, we measured the height and width of the distal femoral epiphysis, the total length of the femur and the length of the proximal femoral bone segment from the femoral head to the proximal bone-prosthesis interface. In addition, post-operative assessments of leg lengths, bilaterally, were documented.

Results: In both patients, distal femoral epiphyseal height and width in the operated leg showed no significant change following endoprosthetic replacement. In the female, growth did not resume even after removal of the epiphyseal screws. In both patients, lengths of the femur and the proximal bone segment increased significantly following surgery. The patients demonstrated no clinical leg length discrepancy at the most recent follow-up.

Discussion: This study suggests that the function of the distal femoral growth plate ceases following insertion of joint-sparing distal femoral endoprostheses, probably due to trans-physeal fixation. This does not appear to resume following early removal of distal screws. The proximal growth plate, however, continues to function adequately enough to maintain symmetry in overall leg length.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 80 - 80
1 Jan 2011
Vijayan S Bartlett W Lee R Ostler P Blunn GW Cannon SR Briggs TWR
Full Access

Introduction: Massive endoprostheses are widely employed in limb salvage surgery for malignant bone tumours. Whilst joint preservation rather than replacement is usually attempted, cases arise where there is insufficient bone following tumour resection to allow adequate fixation of a joint sparing prosthesis.

Method: We report a series of four patients (aged 4–12), in which irradiated autologous bone was combined with distal femoral replacement in order to preserve the native hip joint.

Results: There were three cases of Osteosarcoma and one Ewing’s sarcoma. After a mean follow-up of 53.5 months (range 9–168), all four patients are alive without evidence of local recurrence or metastases. One implant was revised after 14 years following fracture of the extending component of the growing endoprosthesis. There were no cases of loosening or peri-prosthetic fracture.

Discussion: This is the first report of a new technique utilising irradiated autologous proximal femoral bone combined with distal femoral replacement in skeletally immature patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1685 - 1689
1 Dec 2010
Gokaraju K Miles J Parratt MTR Blunn GW Pollock RC Skinner JA Cannon SR Briggs TWR

We have reviewed five adult patients treated with endoprosthetic reconstruction of the proximal radius following resection of non-traumatic lesions. The patients had a mean age of 33.4 years (20 to 60) at the time of surgery and the mean follow-up was 7.6 years (0.8 to 16).

Following surgery, all elbows were clinically stable and there was 100% survivorship of the prosthesis. Evaluation of function was assessed clinically and by the Mayo Elbow Performance Score, achieving a mean of 86% (70 to 100).

Results at medium-term follow-up are encouraging with regards to elbow stability, implant survivorship and functional outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1513 - 1520
1 Nov 2009
Sewell MD Spiegelberg BGI Hanna SA Aston WJS Bartlett W Blunn GW David LA Cannon SR Briggs TWR

We undertook a retrospective review of 33 patients who underwent total femoral endoprosthetic replacement as limb salvage following excision of a malignant bone tumour. In 22 patients this was performed as a primary procedure following total femoral resection for malignant disease. Revision to a total femoral replacement was required in 11 patients following failed segmental endoprosthetic or allograft reconstruction. There were 33 patients with primary malignant tumours, and three had metastatic lesions. The mean age of the patients was 31 years (5 to 68). The mean follow-up was 4.2 years (9 months to 16.4 years). At five years the survival of the implants was 100%, with removal as the endpoint and 56% where the endpoint was another surgical intervention. At five years the patient survival was 32%. Complications included dislocation of the hip in six patients (18%), local recurrence in three (9%), peri-prosthetic fracture in two and infection in one. One patient subsequently developed pulmonary metastases. There were no cases of aseptic loosening or amputation. Four patients required a change of bushings. The mean Musculoskeletal Tumour Society functional outcome score was 67%, the mean Harris Hip Score was 70, and the mean Oxford Knee Score was 34.

Total femoral endoprosthetic replacement can provide good functional outcome without compromising patient survival, and in selected cases provides an effective alternative to amputation.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1378 - 1382
1 Oct 2009
Shekkeris AS Hanna SA Sewell MD Spiegelberg BGI Aston WJS Blunn GW Cannon SR Briggs TWR

Endoprosthetic replacement of the distal tibia and ankle joint for a primary bone tumour is a rarely attempted and technically challenging procedure. We report the outcome of six patients treated between 1981 and 2007. There were four males and two females, with a mean age of 43.5 years (15 to 75), and a mean follow-up of 9.6 years (1 to 27). No patient developed a local recurrence or metastasis. Two of the six went on to have a below-knee amputation for persistent infection after a mean 16 months (1 to 31). The four patients who retained their endoprosthesis had a mean musculoskeletal tumour society score of 70% and a mean Toronto extremity salvage score of 71%. All were pain free and able to perform most activities of daily living in comfort.

A custom-made endoprosthetic replacement of the distal tibia and ankle joint is a viable treatment option for carefully selected patients with a primary bone tumour. Patients should, however, be informed of the risk of infection and the potential need for amputation if this cannot be controlled.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1360 - 1365
1 Oct 2009
Sewell MD Spiegelberg BGI Hanna SA Aston WJS Meswania JM Blunn GW Henry C Cannon SR Briggs TWR

We describe the application of a non-invasive extendible endoprosthetic replacement in skeletally-mature patients undergoing revision for failed joint replacement with resultant limb-length inequality after malignant or non-malignant disease. This prosthesis was developed for tumour surgery in skeletally-immature patients but has now been adapted for use in revision procedures to reconstruct the joint or facilitate an arthrodesis, replace bony defects and allow limb length to be restored gradually in the post-operative period.

We record the short-term results in nine patients who have had this procedure after multiple previous reconstructive operations. In six, the initial reconstruction had been performed with either allograft or endoprosthetic replacement for neoplastic disease and in three for non-neoplastic disease. The essential components of the prosthesis are a magnetic disc, a gearbox and a drive screw which allows painless lengthening of the prosthesis using the principle of electromagnetic induction. The mean age of the patients was 37 years (18 to 68) with a mean follow-up of 34 months (12 to 62). They had previously undergone a mean of six (2 to 14) open procedures on the affected limb before revision with the non-invasive extendible endoprosthesis.

The mean length gained was 56 mm (19 to 107) requiring a mean of nine (3 to 20) lengthening episodes performed in the outpatient department. There was one case of recurrent infection after revision of a previously infected implant and one fracture of the prosthesis after a fall. No amputations were performed. Planned exchange of the prosthesis was required in three patients after attainment of the maximum lengthening capacity of the implant. There was no failure of the lengthening mechanism. The Mean Musculoskeletal Tumour Society rating score was 22 of 30 available points (18 to 28).

The use of a non-invasive extendible endoprosthesis in this manner provided patients with good functional results and restoration of leg-length equality, without the need for multiple open lengthening procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1373 - 1377
1 Oct 2009
Spiegelberg BGI Sewell MD Aston WJS Blunn GW Pollock R Cannon SR Briggs TWR

This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee.

In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1257 - 1262
1 Sep 2009
Sundar S Pendegrass CJ Oddy MJ Blunn GW

We used demineralised bone matrix (DBM) to augment re-attachment of tendon to a metal prosthesis in an in vivo ovine model of reconstruction of the extensor mechanism at the knee. We hypothesised that augmentation of the tendon-implant interface with DBM would enhance the functional and histological outcomes as compared with previously reported control reconstructions without DBM. Function was assessed at six and 12 weeks postoperatively, and histological examination was undertaken at 12 weeks.

A significant increase of 23.5% was observed in functional weight-bearing at six weeks in the DBM-augmented group compared with non-augmented controls (p = 0.004). By 12 weeks augmentation with DBM resulted in regeneration of a more direct-type enthesis, with regions of fibrocartilage, mineralised fibrocartilage and bone. In the controls the interface was predominantly indirect, with the tendon attached to the bone graft-hydroxyapatite base plate by perforating collagen fibres.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 815 - 819
1 Jun 2009
Spiegelberg BGI Sewell MD Coltman T Blunn GW Flanagan AM Cannon SR Briggs TWR

We report a case which highlights the progression of osteofibrous dysplasia to adamantinoma and questions whether intralesional curettage is the appropriate treatment. The role of a joint-sparing massive endoprosthesis using cortical fixation is demonstrated and we describe a unique biomedical design which resulted in the manufacture of an end cap to allow amputation through a custom-made proximal tibial replacement, rather than an above-knee amputation following recurrence.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 262 - 262
1 May 2009
Sundar S Pendegrass CJ Blunn GW
Full Access

Research in to tendon-bone healing techniques focus on increasing bone growth at the interface such as cell or growth factor (e.g. BMP-2) augmentation. Demineralised bone matrix (DBM) is osseoinductive and is in use clinically.

Hypothesis: DBM augmentation of a healing tendon-bone interface will result in improved function at 3, 6, 9 and 12 weeks, and a morphology that more closely resembles that of a normal enthesis at 12 weeks.

Materials and methods: An ovine patellar tendon model was used. 19 skeletally mature ewes were allocated to the control group or DBM group. In both groups the patellar tendon was detached, and following tibial tubercle osteotomy, was re-attached using 3 suture anchors. In the DBM group a piece of DBM was placed between the tendon and bone. 2 animals were sacrificed at 6 weeks and 6 animals at 12 weeks. Animals underwent force plate analysis at 3, 6, 9 and 12 weeks. The tendon-bone interface length which was fibrous or fibrocartilaginous, and the area of fibrocartilage, mineralised fibrocartilage and new bone was quantified.

Results: 3 control group animals (33%) failed within 6 weeks. None failed in the DBM group. The DBM group was significantly better than the control at all time points (p< 0.05). DBM produced a significantly more fibrocartilaginous enthesis than the control group (p< 0.05). Controls were significantly more fibrous than the DBM group (p< 0.05). DBM produced significantly more fibrocartilage (p< 0.05), and mineralised fibrocartilage (p< 0.05).

Discussion: 33% of the control group failed within 6 weeks, whilst no failures were observed in the DBM group. DBM animals mobilised earlier and had significantly better function at all time points. Histologically, the DBM group showed a more mature direct type enthesis at earlier time points.

Conclusion: DBM augmentation of a healing tendon-bone interface enhances functional and morphological recovery at earlier time points.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 535 - 541
1 Apr 2008
Pendegrass CJ Sundar S Oddy MJ Cannon SR Briggs T Blunn GW

We used an in vivo model to assess the use of an autogenous cancellous bone block and marrow graft for augmenting tendon reattachment to metallic implants. We hypothesised that augmentation of the tendon-implant interface with a bone block would enable retention of the graft on the implant surface, enhance biological integration, and result in more consistent functional outcomes compared with previously reported morcellised graft augmentation techniques.

A significant improvement in functional weight-bearing was observed between six and 12 weeks. The significant increase in ground reaction force through the operated limb between six and 12 weeks was greater than that reported previously with morcellised graft augmented reconstructions. Histological appearance and collagen fibre orientation with bone block augmentation more closely resembled that of an intact enthesis compared with the morcellised grafting technique. Bone block augmentation of tendon-implant interfaces results in more reliable functional and histological outcomes, with a return to pre-operative levels of weight-bearing by 24 weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 114 - 121
1 Jan 2008
Pendegrass CJ Gordon D Middleton CA Sun SNM Blunn GW

Conventional amputation prostheses rely on the attachment of the socket to the stump, which may lead to soft-tissue complications. Intraosseous transcutaneous amputation prostheses (ITAPs) allow direct loading of the skeleton, but their success is limited by infection resulting from breaching of the skin at the interface with the implant. Keratinocytes provide the skin’s primary barrier function, while hemidesmosomes mediate their attachment to natural ITAP analogues. Keratinocytes must attach directly to the surface of the implant. We have assessed the proliferation, morphology and attachment of keratinocytes to four titaniumalloy surfaces in order to determine the optimal topography in vitro. We used immunolocalisation of adhesion complex components, scanning electron microscopy and transmission electron microscopy to assess cell parameters.

We have shown that the proliferation, morphology and attachment of keratinocytes are affected by the surface topography of the biomaterials used to support their growth. Smoother surfaces improved adhesion. We postulate that a smooth topography at the point of epithelium-ITAP contact could increase attachment in vivo, producing an effective barrier of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1498 - 1503
1 Nov 2007
Hanna SA David LA Aston WJS Gikas PD Blunn GW Cannon SR Briggs TWR

Between 1988 and 2006, 18 patients had a custom-made endoprosthetic replacement of the distal humerus for bone tumours at our institution. There were 11 primary malignant neoplasms, six secondary deposits, and one benign aggressive tumour. The mean follow-up was for 4.4 years (1 to 18.2). Complications occurred in nine patients and included aseptic loosening in three (16.6%), local recurrence in two (11%), infection in two (11%), neuropraxia of the radial nerve in one (5.5%) and a peri-prosthetic fracture in one (5.5%). Excision was inadequate in four patients (22%), all of which developed local recurrence and/or metastases. There were seven deaths from the primary disease after a mean of 2.3 years (1 to 5), one of whom had an above-elbow amputation for local recurrence seven months before death. The remaining six had satisfactory elbow function at their last follow-up. The 11 living patients were evaluated using the Musculoskeletal Tumour Society and Toronto Extremity Salvage scoring systems. The mean scores achieved were 76% (67% to 87%) and 73% (59% to 79%), respectively. Overall, 17 of 18 patients had significant improvement in the degree of their pain following operation.

Custom-made endoprosthetic reconstruction of the elbow for bone tumours is a viable treatment in carefully selected patients. It maintains satisfactory function and provides good pain relief.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 416 - 417
1 Oct 2006
Coathup MJ Smith N Kingsley C Collins L Dattani R Blunn GW
Full Access

Introduction Bone graft supply for impaction grafting can be problematic due to the supply of graft, sterilisation, which alters the biological properties of the graft, and the immunogencity of the graft which may lead to graft rejection. Reducing the amount of graft can be accomplished by using increased amounts of synthetic materials such as hydroxyapatite (HA). This study evaluated the effect of using mixtures of porous HA (Apapore™) with allograft for cemented impaction allografting of the femoral stem in an ovine model. The aim was to test the hypothesis that increased quantities of Apapore™ will be stable and induce similar bone remodelling to that where a 50:50 mixture with allograft was used.

Method Twelve hemi-arthroplasty femoral components were inserted into the right hip of skeletally mature female commercially cross-bred sheep weighing between 65 and 80kg. Femoral components were manufactured from Cobalt Chromium alloy and cemented in place following impaction of the femoral canal. Animals were randomly placed into one of two groups according to the allograft-apapore mixture used. Group 1: Apapore:allograft mixed 50:50. Group 2: Apapore: allograft mixed 90:10. Six animals were investigated in each group. Implants remained in vivo for 6 months. In order to quantify bone formation rates, oxytetracycline injections were given 2 months post-surgery and 3 weeks later, followed by a third administration in the fifth month post-surgery and 3 weeks later. Animals were walked over a force plate pre-operatively and at 8, 16 and 24 weeks post-operatively. Twelve readings of maximum force (Fmax, N/m2) were taken and average values of right over left were calculated as a percentage (%AR/AL) and represented how well the animal used its operated leg where 100% represents full weight-bearing. Thin sections (~70μm thick) were prepared through four regions of the femur. The proximal, mid and tip of the femoral component region and one distal to the implant tip were analysed where bone area, Apapore™ area, Apapore™-bone contact and cement mantle thickness were quantified and compared using image analysis techniques.

Results In both groups, the use of graft resulted in the formation of a cancellous network of bone on the endosteal surface which incorporated the Apapore™ granules. When all regions were compared, femoral bone turnover results demonstrated significantly increased rates in group 1 (0.0021mm day-1) when compared with group 2 (0.0015mm day-1) (p< 0.05). No significant differences were identified when the proximal, mid and tip regions in the two groups were compared however, significantly increased turnover was identified in the distal region in group 1 (0.0027 mm day-1) when compared with group 2 (0.0013mm day-1) (p< 0.05). In both groups increased turnover was observed in the proximal, tip and distal regions with least in the mid region of the stem. Ground Reaction Force (GRF) results demonstrated no significant differences between the two experimental groups at 8, 16 and 24 weeks postoperatively. In both groups, a significant decline in function was demonstrated 8 weeks post-op when compared with pre-operative values and in both groups function gradually increased over time. Results for new bone area demonstrated significantly increased new bone in the proximal and distal regions in both groups (proximal =7.94mm2 and 7.13mm2; distal =7.03mm2 and 8.17mm2, group 1 and 2 respectively) with least new bone in the mid region of the stem (4.53mm2 and 4.79mm2). No significant differences in any of the regions were demonstrated when group 1 and 2 were compared. In both groups, significantly increased amounts of Apapore™ was observed in the proximal and distal regions of the femoral stem with least in the mid and tip region. No significant difference in cement mantle thickness was identified between the two groups.

Discussion Results demonstrated that hips maintained functional stability when a higher amount of Apapore™ mixture was used. Results for bone turnover rates and the amount of new bone formation in the 90:10 mixture demonstrated Apapore™ to be a comparable and suitable alternative to replace allograft in impaction grafting of a femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1245 - 1251
1 Sep 2006
Pendegrass CJ Oddy MJ Sundar S Cannon SR Goodship AE Blunn GW

We examined the mechanical properties of Vicryl (polyglactin 910) mesh in vitro and assessed its use in vivo as a novel biomaterial to attach tendon to a hydroxyapatite-coated metal implant, the interface of which was augmented with autogenous bone and marrow graft. This was compared with tendon re-attachment using a compressive clamp device in an identical animal model. Two- and four-ply sleeves of Vicryl mesh tested to failure under tension reached 5.13% and 28.35% of the normal ovine patellar tendon, respectively. Four-ply sleeves supported gait in an ovine model with 67.05% weight-bearing through the operated limb at 12 weeks, without evidence of mechanical failure.

Mesh fibres were visible at six weeks but had been completely resorbed by 12 weeks, with no evidence of chronic inflammation. The tendon-implant neoenthesis was predominantly an indirect type, with tendon attached to the bone-hydroxyapatite surface by perforating collagen fibres.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 257 - 257
1 May 2006
Wardle NS Lee JKL Haddad FS Blunn GW
Full Access

Background And Aims: Total knee replacements provide a cost effective treatment for painful joint conditions such as osteoarthritis. Their long term performance is governed by ultra-high molecular weight polyethylene (UHMWPE) wear which produces wear debris and leads to osteolysis and aseptic loosening of the implant. Using a new material which is more scratch resistant than cobalt chrome it is hoped to reduce wear of UHMWPE and its subsequent complications.

Methods: Two total knee replacements made from cobalt chrome and two of oxidised zirconium were wear tested in a knee simulator. Surface roughness data from the femoral components was collected. Gravimetric and volumetric wear of the polyethylene inserts was measured. SEM analysis of the surfaces was also performed.

Results: Oxidised zirconium is significantly more scratch resistant than CoCr; Ra (mean average roughness) of 0.7μm compared to 0.43μm (p< < 0.01) at end of test, and confirmed by SEM analysis. This was accompanied by a 4 fold reduction in wear of UHMWPE 49.60mg to 12.48mg (p=0.02). Barium sulphate particles were found to be embedded in the surface of the CoCr implants.

Summary And Conclusions: Oxidised zirconium leads to a reduction in wear of UHMWPE due to its increased resistance to third body wear. It has the potential to increase the longevity of total knee replacements by reducing UHMWPE related complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 873 - 878
1 Jun 2005
Oddy MJ Pendegrass CJ Goodship AE Cannon SR Briggs TWR Blunn GW

We developed an in vivo model of the attachment of a patellar tendon to a metal implant to simulate the reconstruction of an extensor mechanism after replacement of the proximal tibia. In 24 ewes, the patellar tendon was attached to a hydroxyapatite (HA)-coated titanium prosthesis. In 12, the interface was augmented with autograft containing cancellous bone and marrow. In the remaining ewes, the interface was not grafted.

Kinematic gait analysis showed nearly normal function of the joint by 12 weeks. Force-plate assessment showed a significant increase in functional weight-bearing in the grafted animals (p = 0.043). The tendon-implant interface showed that without graft, encapsulation of fibrous tissue occurred. With autograft, a developing tendon-bone-HA-implant interface was observed at six weeks and by 12 weeks a layered tendon-fibrocartilage-bone interface was seen which was similar to a direct-type enthesis.

With stable mechanical fixation, an appropriate bioactive surface and biological augmentation the development of a functional tendon-implant interface can be achieved.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 118 - 123
1 Jan 2001
Coathup MJ Blunn GW Flynn N Williams C Thomas NP

We investigated the implant-bone interface around one design of femoral stem, proximally coated with either a plasma-sprayed porous coating (plain porous) or a hydroxyapatite porous coating (porous HA), or which had been grit-blasted (Interlok). Of 165 patients implanted with a Bimetric hip hemiarthroplasty (Biomet, Bridgend, UK) specimens were retrieved from 58 at post-mortem.

We estimated ingrowth and attachment of bone to the surface of the implant in 21 of these, eight plain porous, seven porous HA and six Interlok, using image analysis and light morphometric techniques. The amount of HA coating was also quantified.

There was significantly more ingrowth (p = 0.012) and attachment of bone (p > 0.05) to the porous HA surface (mean bone ingrowth 29.093 ± 2.019%; mean bone attachment 37.287 ± 2.489%) than to the plain porous surface (mean bone ingrowth 21.762 ± 2.068%; mean bone attachment 18.9411 ± 1.971%). There was no significant difference in attachment between the plain porous and Interlok surfaces. Bone grew more evenly over the surface of the HA coating whereas on the porous surface, bone ingrowth and attachment occurred more on the distal and medial parts of the coated surface. No significant differences in the volume of HA were found with the passage of time.

This study shows that HA coating increases the amount of ingrowth and attachment of bone and leads to a more even distribution of bone over the surface of the implant. This may have implications in reducing stress shielding and limiting osteolysis induced by wear particles.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 927 - 937
1 Nov 1997
Schindler OS Cannon SR Briggs TWR Blunn GW

The use of extendible distal femoral replacements is a relatively new treatment alternative for malignant bone tumours in growing individuals. Although their appearance was widely appreciated, questions about functional practicality and longevity remain unclear. With longer follow-up, advantages of immediate functional restoration and beneficial psychological aspects seem to be overshadowed by an increase in complications such as aseptic loosening, infection or prosthetic failure.

We have reviewed 18 children with such tumours who were treated between 1983 and 1990 by custom-made Stanmore extendible distal femoral replacements. Four died from metastatic disease within 2.5 years of operation and two required amputation for local recurrence or chronic infection.

The remaining 12 patients were followed for a mean of 8.7 years (6 to 13.2). A mean total lengthening of 5.2 cm was achieved, requiring, on average, 4.3 operations. Using the Musculoskeletal Tumor Society rating score the functional result at review was, on average, 77% of the expected normal function, with seven patients achieving ≥ 80%. Revision of the prosthesis was required in ten patients, in six for aseptic loosening, at a mean of 6.2 years after the initial procedure.