header advert
Results 1 - 20 of 41
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1702 - 1708
1 Nov 2021
Lawrie CM Kazarian GS Barrack T Nunley RM Barrack RL

Aims

Intra-articular administration of antibiotics during primary total knee arthroplasty (TKA) may represent a safe, cost-effective strategy to reduce the risk of acute periprosthetic joint infection (PJI). Vancomycin with an aminoglycoside provides antimicrobial cover for most organisms isolated from acute PJI after TKA. However, the intra-articular doses required to achieve sustained therapeutic intra-articular levels while remaining below toxic serum levels is unknown. The purpose of this study is to determine the intra-articular and serum levels of vancomycin and tobramycin over the first 24 hours postoperatively after intra-articular administration in primary cementless TKA.

Methods

A prospective cohort study was performed. Patients were excluded if they had poor renal function, known allergic reaction to vancomycin or tobramycin, received intravenous vancomycin, or were scheduled for same-day discharge. All patients received 600 mg tobramycin and 1 g of vancomycin powder suspended in 25 cc of normal saline and injected into the joint after closure of the arthrotomy. Serum from peripheral venous blood and drain fluid samples were collected at one, four, and 24 hours postoperatively. All concentrations are reported in µg per ml.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1449 - 1456
1 Sep 2021
Kazarian GS Lieberman EG Hansen EJ Nunley RM Barrack RL

Aims

The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following total knee arthroplasty (TKA).

Methods

A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using the Ovid Medline, Embase, Cochrane Central, and Web of Science databases in order to assess the impact of the patient-reported outcomes measures (PROMs) and implant placement accuracy on outcomes following TKA. Studies assessing the impact of implant alignment, rotation, size, overhang, or condylar offset were included. Study quality was assessed, evidence was graded (one-star: no evidence, two-star: limited evidence, three-star: moderate evidence, four-star: strong evidence), and recommendations were made based on the available evidence.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 73 - 77
1 Jul 2021
Lawrie CM Barrack RL Nunley RM

Aims

Dual mobility (DM) implants have been shown to reduce the dislocation rate after total hip arthroplasty (THA), but there remain concerns about the use of cobalt chrome liners inserted into titanium shells. The aim of this study was to assess the clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) at mid-term follow-up in young, active patients receiving a modular DM THA.

Methods

This was a prospective study involving patients aged < 65 years, with a BMI of < 35 kg/m2, and University of California, Los Angeles activity score of > 6 who underwent primary THA with a modular cobalt chrome acetabular liner, highly cross-linked polyethylene mobile bearing, and a cementless titanium femoral stem. Patient-reported outcome measures, whole blood metal ion levels (μg/l), and periprosthetic femoral BMD were measured at baseline and at one, two, and five years postoperatively. The results two years postoperatively for this cohort have been previously reported.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 98 - 102
1 Jul 2021
Freiman S Schwabe MT Barrack RL Nunley RM Clohisy JC Lawrie CM

Aims

The purpose of this study was to determine the access to and ability to use telemedicine technology in adult patients undergoing total hip arthroplasty (THA) and total knee arthroplasty (TKA), and to determine associations with the socioeconomic characteristics of the patients, including age, sex, race, and education. We also sought to understand the patients’ perceived benefits, risks, and preferences when dealing with telemedicine.

Methods

We performed a cross-sectional survey involving patients awaiting primary THA and TKA by one of six surgeons at a single academic institution. Patients were included and called for a telephone-administered survey if their surgery was scheduled to be between 23 March and 2 June 2020, and were aged > 18 years.


Bone & Joint Open
Vol. 2, Issue 3 | Pages 191 - 197
1 Mar 2021
Kazarian GS Barrack RL Barrack TN Lawrie CM Nunley RM

Aims

The purpose of this study was to compare the radiological outcomes of manual versus robotic-assisted medial unicompartmental knee arthroplasty (UKA).

Methods

Postoperative radiological outcomes from 86 consecutive robotic-assisted UKAs (RAUKA group) from a single academic centre were retrospectively reviewed and compared to 253 manual UKAs (MUKA group) drawn from a prior study at our institution. Femoral coronal and sagittal angles (FCA, FSA), tibial coronal and sagittal angles (TCA, TSA), and implant overhang were radiologically measured to identify outliers.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 18 - 18
1 Oct 2020
Nunley RM Barrack RL Lawrie CM
Full Access

Introduction

Modular dual mobility (MDM) prostheses are increasingly utilized for total hip arthroplasty (THA) to mitigate the risk of postoperative instability in high risk patients. Short-term reports on clinical outcomes are favorable but there are few studies on young active patients. This study quantified proximal femoral stress shielding and metal ion release in MDM combined with modern cementless stem design in young active patients.

Methods

This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m2 and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. DEXA scans were performed at 6 weeks postoperatively as a baseline, then again at 6 months, 1 year, 2 years and 5 years postoperatively as were metal ions.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 54 - 54
1 Oct 2020
Freiman S Schwabe M Pashos G Barrack RL Nunley R Adelani M Pascual-Garrido C Clohisy J Lawrie C
Full Access

Introduction

The purpose of the study was to determine access to and, ability to use telemedicine technology in an adult hip and knee reconstruction patient population and we seek to understand these patients' perceived benefits, risks and preferences of telemedicine.

Methods

We performed a cross-sectional telephone administered survey on patients scheduled to undergo primary THA and TKA by one of six surgeons at a single academic institution between March 23 and June 2, 2020.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 24 - 24
1 Oct 2020
Kazarian GS Barrack RL Barrack TN Lawrie CM Nunley RM
Full Access

Introduction

The purpose of this study was to compare the radiographic outcomes of manual versus robotic-assisted medial unicompartmental knee arthroplasty (UKA).

Materials & Methods

Postoperative radiographic outcomes from 86 consecutive robotic-assisted UKAs (RAUKA group) from a single academic center were retrospectively reviewed and compared to 253 manual UKAs (MUKA group) drawn from a prior study at our institution. Femoral coronal and sagittal angles (FCA, FSA), tibial coronal and sagittal angles (TCA, TSA), and implant overhang were radiographically measured to identify outliers. Clinical results at 4–6 weeks postoperative were compared to a control cohort of total knee arthroplasty (TKA) patients from our institution.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 69 - 69
1 Oct 2020
Lawrie CM Barrack RL Nunley RM
Full Access

Introduction

Bone mineral density (BMD) is correlated with component migration and aseptic loosening after total knee arthroplasty (TKA). Older implant designs have demonstrated BMD loss up to 23% in the first 6 months after TKA, and continued to BMD decline at an average of 5% per year for as long as 2 years after TKA. The impact of component design and fixation method on BMD loss after TKA in modern implant designs has not been fully elucidated. The purpose of this study is to determine the effect of tibial tray thickness and fixation method (cemented versus cementless) on BMD loss patterns of the proximal tibia in two different modern TKA implant systems

Methods

A prospective, nonrandomized, single center study of patients undergoing primary TKA by one of two surgeons was performed with four study cohorts: cemented DePuy Attune, cementless DePuy Attune, cemented Stryker Triathlon, cementless Stryker Triathlon. Target sample size was 80, with 20 per cohort based on adhoc power analysis. Exclusion criteria included: age over 75, BMI >40, inflammatory arthritis, previous knee surgery involving the femur, tibia or tibial bone, and diagnosis of osteopenia/osteoporosis. Implant fixation type was based on surgeon intraoperative assessment of patient bone quality. Demographic data was collected preoperatively. Dual Energy X-ray Absorptiometry (DEXA) Bone Density Monitoring was performed at 6 weeks and one year postoperatively. Bone mineral density was calculated from the DEXA scans for 4 zones for the tibia relative to the keel or central peg: anterior, posterior, medial and lateral. Results were reported as BMD at 1 year postoperatively as a percentage of BMD at 6 weeks postoperatively.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 47 - 51
1 Jul 2020
Kazarian GS Schloemann DT Barrack TN Lawrie CM Barrack RL

Aims

The aims of this study were to determine the change in the sagittal alignment of the pelvis and the associated impact on acetabular component position at one-year follow-up after total hip arthroplasty (THA).

Methods

This study represents the one-year follow-up of a previous short-term study at our institution. Using the patient population from our prior study, the radiological pelvic ratio was assessed in 91 patients undergoing THA, of whom 50 were available for follow-up of at least one year (median 1.5; interquartile range (IQR) 1.1 to 2.0). Anteroposterior radiographs of the pelvis were obtained in the standing position preoperatively and at one year postoperatively. Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Apparent acetabular component position changes were determined from the change in pelvic ratio. A change of at least 5° was considered clinically meaningful.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 163 - 169
1 Jun 2020
Lawrie CM Jo S Barrack T Roper S Wright RW Nunley RM Barrack RL

Aims

The aim of this study was to determine if the local delivery of vancomycin and tobramycin in primary total knee arthroplasty (TKA) can achieve intra-articular concentrations exceeding the minimum inhibitory concentration thresholds for bacteria causing acute prosthetic joint infection (PJI).

Methods

Using a retrospective single-institution database of all primary TKAs performed between January 1 2014 and May 7 2019, we identified patients with acute PJI that were managed surgically within 90 days of the initial procedure. The organisms from positive cultures obtained at the time of revision were tested for susceptibility to gentamicin, tobramycin, and vancomycin. A prospective study was then performed to determine the intra-articular antibiotic concentration on postoperative day one after primary TKA using one of five local antibiotic delivery strategies with tobramycin and/or vancomycin mixed into the polymethylmethacrylate (PMMA) or vancomycin powder.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 4 - 4
1 Oct 2019
Lawrie CM Okafor LC Kazarian GS Barrack TN Barrack RL Nunley RM
Full Access

Background

The purpose of this study was to assess the overall clinical and radiographic outcomes of unicompartmental knee arthroplasty (UKA) in the 2–10 year postoperative period. The secondary goal was to compare outcomes between fixed- (FB) and mobile-bearing (MB) implant designs.

Methods

We performed a retrospective analysis of 237 consecutive primary medial UKAs from a single academic center. All cases were performed by high-volume fellowship-trained arthroplasty surgeons, though UKA comprised <10% of their overall knee arthroplasty practice (<20 medial UKAs per surgeon per year). Clinical outcomes included the Oxford Knee Scores (OKS) and revision rates. Femoral and tibial coronal and sagittal angles (FCA, FSA, TCA, TSA) were radiographically measured. FCA (>±10º deviation from the neutral axis), FSA (>15º flexion), TCA (>±5º deviation from the neutral axis), and TSA (>±5º deviation from 7º) outliers were defined. Far outliers were defined as measurements that fell an additional >±2º outside of these ranges. Outcomes were compared between the FB and MB groups.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 34 - 34
1 Oct 2019
Lawrie CM Jo S Barrack TN Barrack RL
Full Access

Introduction

Periprosthetic infection (PJI) after primary total knee arthroplasty (TKA) remains a challenging issue affecting 1–2% of cases. Locally delivered prophylactic antibiotics, including tobramycin or gentamicin mixed in polymethylmethacrylate (PMMA) bone cement and vancomycin powder, are increasingly used despite a lack of high quality evidence for either practice. In this study, we report the antibiotic susceptibility of organisms recovered in culture from patients with acute prosthetic joint infection after primary TKA to gentamicin, tobramycin and vancomycin.

Methods

Using a retrospective database of all primary TKA performed at a single institution between January, 1 2014 and July 1, 2018, we identified 18 cases of acute PJI after primary TKA, as defined by the Musculoskeletal Infection Society 2011 guidelines as less than 3 months from symptoms or index surgery to presentation. The use of antibiotic bone cement during the index procedure and time to surgical management of the infection were recorded. Fluid cultures and tissue cultures were obtained intraoperatively at the time of revision. The organisms from positive cultures underwent MIC testing to gentamicin, tobramycin and vancomycin using a gradient diffusion method (ETEST). MIC breakpoints for susceptibility were based on Clinical and Laboratory Standards Institute definitions.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 23 - 23
1 Oct 2019
Lawrie CM Barrack TR Abu-Amer W Adelani MA Clohisy JC Barrack RL Nunley RM
Full Access

Introduction

The utility and yield of the current practice of routine screening of asymptomatic patients after primary total hip arthroplasty (THA) and total knee arthroplasty (TKA) is unclear. The purpose of this prospective survey study was to determine the utility of the routine on year follow up visit primary THA and TKA.

Methods

We prospectively enrolled all patients undergoing primary THA and TKA. At one-year follow-up, patients were asked to complete a survey that asked about satisfaction with the and if they thought the visit was worthwhile. Surgeons also completed a survey which asked if any intervention was done, if any problems were diagnosed/avoided, and if the visit was worthwhile. Data was analyzed and compared between patients and surgeons, and was also compared to the need for any additional interventions


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 8 - 8
1 Oct 2019
Lawrie CM Schloemann D Kazarian GS Barrack TN Barrack RL
Full Access

Background

The aim of this study was to determine the change in standing pelvic sagittal alignment and associated impact on functional acetabular component position at follow-up after total hip arthroplasty (THA).

Patients and Methods

A retrospective review was performed on 91 consecutive patients who had undergone primary THA by a single surgeon via a posterior approach in the lateral decubitus position. Of these, 41 patients had high quality standing AP pelvis radiographs preoperatively, at six weeks postoperatively, and at one year postoperatively available for analysis. Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Apparent changes in the functional acetabular component position were determined from the change in pelvic ratio between the preoperative and one year postoperative standing AP pelvic radiograph. A change of at least five degrees was considered clinically meaningful.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 61 - 63
1 Jul 2019
Lawrie CM Schwabe M Pierce A Nunley RM Barrack RL

Aims

The aim of this study was to compare the actual cost of a cemented and cementless total knee arthroplasty (TKA) procedure.

Materials and Methods

The cost of operative time, implants, cement, and cementing accessories were included in the overall cost of the TKA procedure. Operative time was determined from a previously published study comparing cemented and cementless implants of the same design. The cost of operative time, implants, cement, and cementing accessories was determined from market and institutional data.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 31 - 36
1 Jun 2019
Nam D Nunley RM Clohisy JC Lombardi AV Berend KR Barrack RL

Aims

Whether patient-reported pain differs among surgical approaches in total hip arthroplasty (THA) remains unclear. This study’s purposes were to determine differences in pain based on surgical approach (direct anterior (DA) vs posterolateral (PL)) and PL approach incision length.

Patients and Methods

This was a retrospective investigation from two centres and seven surgeons (three DA, three PL, one both) of primary THAs. PL patients were categorized for incision length (6 cm to 8 cm, 8 cm to 12 cm, 12 cm to 15 cm). All patients had cementless femoral and acetabular fixation, at least one year’s follow-up, and well-fixed components. Patients completed a pain-drawing questionnaire identifying the location and intensity of pain on an anatomical diagram. Power analysis indicated 800 patients in each cohort for adequate power to detect a 4% difference in pain (alpha = 0.05, beta = 0.80).


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 45 - 50
1 Jun 2019
Schloemann DT Edelstein AI Barrack RL

Aims

The aims of this study were to determine the change in pelvic sagittal alignment before, during, and after total hip arthroplasty (THA) undertaken with the patient in the lateral decubitus position, and to determine the impact of these changes on acetabular component position.

Patients and Methods

We retrospectively compared the radiological pelvic ratio among 91 patients undergoing THA. In total, 41 patients (46%) were female. The mean age was 61.6 years (sd 10.7) and the mean body mass index (BMI) was 20.0 kg/m2 (sd 5.5). Anteroposterior radiographs were obtained: in the standing position preoperatively and at six weeks postoperatively; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post-anaesthesia care unit. Pelvic ratio was defined as the ratio between the vertical distance from the inferior aspect of the sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior aspect of the SI joints. Changes in the apparent component position based on changes in pelvic ratio were determined, with a change of > 5° considered clinically significant. Analyses were performed using Wilcoxon’s signed-rank test, with p < 0.05 considered significant.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 365 - 371
1 Apr 2019
Nam D Salih R Nahhas CR Barrack RL Nunley RM

Aims

Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell (vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed ‘high-risk’ for dislocation undergoing total hip arthroplasty (THA), their performance in young, active patients has not been reported. This study’s purpose was to assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular DM acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design.

Patients and Methods

This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m2 and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (sd 6.5)) were enrolled. All patients had a minimum of two years’ clinical follow-up. Patient-reported outcome measures, whole blood metal ion levels (ug/l), and periprosthetic femoral BMD were measured at baseline, as well as at one and two years postoperatively. Power analysis indicated 40 patients necessary to demonstrate a five-fold increase in cobalt levels from baseline (alpha = 0.05, beta = 0.80). A mixed model with repeated measures was used for statistical analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 32 - 40
1 Jan 2019
Hellman MD Ford MC Barrack RL

Aims

Surface replacement arthroplasty (SRA), compared with traditional total hip arthroplasty (THA), is more expensive and carries unique concern related to metal ions production and hypersensitivity. Additionally, SRA is a more demanding procedure with a decreased margin for error compared with THA. To justify its use, SRA must demonstrate comparable component survival and some clinical advantages. We therefore performed a systematic literature review to investigate the differences in complication rates, patient-reported outcomes, stress shielding, and hip biomechanics between SRA and THA.

Materials and Methods

A systematic review of the literature was completed using MEDLINE and EMBASE search engines. Inclusion criteria were level I to level III articles that reported clinical outcomes following primary SRA compared with THA. An initial search yielded 2503 potential articles for inclusion. Exclusion criteria included review articles, level IV or level V evidence, less than one year’s follow-up, and previously reported data. In total, 27 articles with 4182 patients were available to analyze.