header advert
Results 1 - 20 of 34
Results per page:
Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims

A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis.

Methods

Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 49 - 49
23 Jun 2023
McCalden R Pomeroy E Naudie D Vasarhelyi E Lanting B MacDonald S Howard J
Full Access

Subsidence remains a concern when utilizing modern tapered fluted titanium (TFT) femoral stems and may lead to leg length discrepancy, impingement, instability and failure to obtain stem osseointegration. This study aims to compare stem subsidence across three modern TFT stems. Our secondary aim was to investigate the influence of bicortical contact or ‘scratch fit’ on subsidence, as well as the role of intraoperative imaging in maximizing this bicortical contact and preventing stem subsidence.

A retrospective review of 271 hip arthroplasties utilizing modern TFT stems in a single institution was performed. Three stem designs were included in the analysis: one monoblock TFT stem (n=91) and two modular TFT stems (Modular A [n=90]; Modular B [n=90]). Patient demographics, Paprosky femoral bone loss classification, bi-cortical contact, utilization of intra-operative imaging and stem subsidence (comparison of initial post-operative radiograph to the latest follow up radiograph - minimum three months) were recorded.

There was no statistically significant difference in the amount of subsidence between the three stems (Monoblock: 2.33mm, Modular A: 3.43mm, Modular B: 3.02mm; p=0.191). There was no statistical difference in subsidence >5mm between stems (Monoblock: 9.9%, Modular A: 22.2%, Modular B: 16.7%). Subgroup analysis based on femoral bone loss grading showed no difference in subsidence between stems. Increased bicortical contact was strongly associated with reduced subsidence (p=0.004). Intra-operative imaging was used in 46.5% (126/271) of cases; this was not correlated with bicortical contact (p=0.673) or subsidence (p=0.521). Across all groups, only two stems were revised for subsidence (0.7%).

All three modern TFT stems were highly successful and associated with low rates of subsidence, regardless of modular or monoblock design. Surgeons should select the stem that they feel is most clinically appropriate.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 78 - 78
1 Dec 2022
Dilernia FD Watson D Heinrichs D Vasarhelyi E
Full Access

Staphylococcus aureus is the most frequently isolated organism in periprosthetic joint infections. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding of its antibacterial characteristics is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against S. aureus.

SF samples were collected from patients undergoing total elective knee or hip arthroplasty. Different S. aureus strains previously found to be sensitive and resistant, UAMS-1 and USA300 WT, respectively, were used. We performed in-vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated the sensitivity to killing, comparing WT and CopAZB-deficient USA300 strains.

UAMS-1 evidenced a greater sensitivity to SF when compared to USA300 WT, at 12 (p=0.001) and 24 hours (p=0.027). UAMS-1 significantly died at 24 hours (p=0.017), and USA300 WT survived at 24 hours. UAMS-1 was more susceptible to the addition of copper at 4 (p=0.001), 12 (p=0.005) and 24-hours (p=0.006). We confirmed a high sensitivity to killing with the addition of exogenous copper on both strains at 4 (p=0.011), 12 (p=0.011), and 24 hours (p=0.011). Both WT and CopAZB-deficient USA300 strains significantly died in SF, evidencing a MBC-Cu of 50µM against USA300 WT (p=0.011).

SF has antimicrobial properties against S. aureus, and UAMS-1 was more sensitive than USA300 WT. The addition of 10µM of copper was highly toxic for both strains, confirming its bactericidal effect. We evidenced CopAZB-proteins involvement in copper effluxion by demonstrating the high sensitivity of the mutant strain to lower copper concentrations. Thus, we propose CopAZB-proteins as potential targets and the use of exogenous copper as possible treatment alternatives against S. aureus.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 21 - 21
1 Aug 2020
Somerville L Zomar B Vasarhelyi E Lanting B Howard J Marsh J
Full Access

Total knee arthroplasty is a successful procedure that reduces knee pain and improves function in most patients with knee osteoarthritis. Patient dissatisfaction however remains high, and along with implant longevity, may be affected by component positioning. Surgery in obese patients is more technically challenging with difficulty identifying appropriate landmarks for alignment and more difficult exposure of the joint. Patient specific instrumentation (PSI) has been introduced with the goal to increase accuracy of component positioning by custom fitting cutting guides to the patient using advanced imaging. A strong criticism of this new technology however, is the cost associated. The purpose of this study was to determine, using a prospective, randomized-controlled trial, the cost-effectiveness of PSI compared to standard instrumentation for total knee arthroplasty in an obese patient population.

Patients with a body mass index greater than 30 with osteoarthritis and undergoing a primary total knee arthroplasty were included in this study. We randomized patients to have their procedure with either standard instrumentation (SOC) or PSI. At 12-weeks post-surgery patients completed a self-reported cost questionnaire and the Western Ontario and McMaster Osteoarthritis Index (WOMAC). We performed a cost-effectiveness analyses from a public health payer and societal perspective. As we do not know the true cost of the PSI instrumentation, we estimated a value of $100 for our base case analysis and used one-way sensitivity analyses to determine the effect of different values (ranging from $0 to $500) would have on our conclusions.

A total of 173 patients were enrolled in the study with 86 patients randomized to the PSI group and 87 to the SOC group. We found the PSI group to be both less effective and more costly than SOC when using a public payer perspective, regardless of the cost of the PSI. From a societal perspective, PSI was both less costly, but also less effective, regardless of the cost of the PSI. The mean difference in effect between the two groups was −1.61 (95% CI −3.48, 026, p=0.091). The incremental cost-effectiveness ratio was $485.71 per point increase in the WOMAC, or $7285.58 per clinically meaningful difference (15 points) in the WOMAC.

Overall, our results suggest that PSI is not cost-effective compared to standard of care from a public payer perspective. From a societal perspective, there is some question as to whether the decreased effect found with the PSI group is worth the reduced cost. The main driver of the cost difference appears to be time off of volunteer work, which will need to be investigated further. In future, we will continue to follow these patients out to one year to collect cost and effectiveness data to investigate whether these results remain past 12 weeks post-surgery.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 32 - 32
1 Jul 2020
Perelgut M Teeter M Lanting B Vasarhelyi E
Full Access

Increasing pressure to use rapid recovery care pathways when treating patients undergoing total hip arthroplasty (THA) is evident in current health care systems for numerous reasons. Patient autonomy and health care economics has challenged the ability of THA implants to maintain functional integrity before achieving bony union. Although collared stems have been shown to provide improved axial stability, it is unclear if this stability correlates with activity levels or results in improved early function to patients compared to collarless stems. This study aims to examine the role of implant design on patient activity and implant fixation. The early follow-up period was examined as the majority of variation between implants is expected during this time-frame.

Patients (n=100) with unilateral hip OA who were undergoing primary THA surgery were recruited pre-operatively to participate in this prospective randomized controlled trial. All patients were randomized to receive either a collared (n=50) or collarless (n=50) cementless femoral stem. Patients will be seen at nine appointments (pre-operative, < 2 4 hours post-operation, two-, four-, six-weeks, three-, six-months, one-, and two-years). Patients completed an instrumented timed up-and-go (TUG) test using wearable sensors at each visit, excluding the day of their surgery. Participants logged their steps using Fitbit activity trackers and a seven-day average prior to each visit was recorded. Patients also underwent supine radiostereometric analysis (RSA) imaging < 2 4 hours post-operation prior to leaving the hospital, and at all follow-up appointments.

Nineteen collared stem patients and 20 collarless stem patients have been assessed. There were no demographic differences between groups. From < 2 4 hours to two weeks the collared implant subsided 0.90 ± 1.20 mm and the collarless implant subsided 3.32 ± 3.10 mm (p=0.014). From two weeks to three months the collared implant subsided 0.65 ± 1.54 mm and the collarless implant subsided 0.45 ± 0.52 mm (p=0.673). Subsidence following two weeks was lower than prior to two weeks in the collarless group (p=0.02) but not different in the collared group. Step count was reduced at two weeks compared to pre-operatively by 4078 ± 2959 steps for collared patients and 4282 ± 3187 steps for collarless patients (p=0.872). Step count increased from two weeks to three months by 6652 ± 4822 steps for collared patients and 4557 ± 2636 steps for collarless patients (p=0.289). TUG test time was increased at two weeks compared to pre-operatively by 4.71 ± 5.13 s for collared patients and 6.54 ± 10.18 s for collarless patients (p=0.551). TUG test time decreased from two weeks to three months by 7.21 ± 5.56 s for collared patients and 8.38 ± 7.20 s for collarless patients (p=0.685). There was no correlation between subsidence and step count or TUG test time.

Collared implants subsided less in the first two weeks compared to collarless implants but subsequent subsidence after two weeks was not significantly different. The presence of a collar on the stem did not affect patient activity and function and these factors were not correlated to subsidence, suggesting that initial fixation is instead primarily related to implant design.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 71 - 71
1 Jul 2020
Vissa D Lin C Ganapathy S Bryant D Adhikari D MacDonald S Lanting B Vasarhelyi E Howard J
Full Access

Dexmedetomidine, an alpha 2 agonist, has been approved for providing sedation in the intensive care unit. Along with sedative properties, it has analgesic activity through its highly selective action on alpha 2 receptors. Recent studies have examined the use of dexmedetomidine as an adjuvant to prolong the duration of peripheral nerve blocks. Studies showing effectiveness of dexmedetomidine for adductor canal block in knee surgery are small. Also, its effectiveness has not been compared to Epinephrine which is a strong alpha and beta receptor agonist. In a previous study, we showed that motor sparing knee blocks significantly increased the duration of analgesia compared with periarticular knee infiltration using local anesthetic mixture containing Epinephrine following total knee arthroplasty (TKA). In this study, we compared two local anesthetic mixtures: one containing Dexmedetomidine and the other Epinephrine for prolongation of motor sparing knee block in primary TKA patients.

After local ethics board approval and gaining Notice of Compliance (NOC) from Health Canada for use of Dexmedetomidine perineurally, 70 patients between the ages 18 – 95 of ASA class I to III undergoing unilateral primary total knee arthroplasty were enrolled. Motor sparing knee block − 1) Adductor canal continuous catheter 2) Single shot Lateral Femoral Cutaneous Nerve block 3) Single shot posterior knee infiltration was performed in all patients using 60 ml mixture of 0.5% Ropivacaine, 10 mg Morphine, 30 mg Ketorolac. Patients randomized into the Dexmedetomidine group (D) received, in addition to the mixture, 1mcg/kg Dexmedetomidine and the Epinephrine (E) group received 200mcg in the mixture. The primary outcome was time to first rescue analgesia as a surrogate for duration of analgesia and secondary outcomes were NRS pain scores up to 24 hours and opioid consumption.

The time to first rescue analgesia was not significantly different between Epinephrine and dexmedetomidine groups, Mean and SD 18.45 ± 12.98 hours vs 16.63 ± 11.80 hours with a mean difference of 1.82 hours (95% CI −4.54 to 8.18 hours) and p value of 0.57. Pain scores at 4, 6, 12, 18 and 24 hours were comparable between groups. Mean NRS pain scores Epinephrine vs Dexmedetomidine groups were 1.03 vs 0.80 at 4 hours, 1.48 vs 3.03 at 6 hours, 3.97 vs 4.93 at 12 hours, 5.31 vs 6.18 and 6.59 v 6.12 at 24 hours. Opioid consumption was also not statistically significant between both groups at 6, 12 18, 24 hours (p values 0.18, 0.88, 0.09, 0.64 respectively).

Dexmedetomidine does not prolong the duration of knee motor sparing blocks when compared to Epinephrine for total knee arthroplasty. Pain scores and opioid consumption was also comparable in both groups. Further studies using higher dose of dexmedetomidine are warranted.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 56 - 56
1 Feb 2020
Broberg J Howard J Lanting B Vasarhelyi E Yuan X Naudie D Teeter M
Full Access

Introduction

Surgeons performing a total knee replacement (TKR) have two available techniques available to help them achieve the proper bone resections and ligament tension – gap balancing (GB) and measured resection (MR). GB relies on balancing ligaments prior to bony resections whereas bony resections are made based on anatomical landmarks in MR. Many studies have been done to compare the joint kinematics between the two techniques, however the results have been varied. These studies were not done with anatomically designed prostheses. The Journey II (Smith & Nephew, Memphis, TN) is one such design which attempts to mimic the normal knee joint structure to return more natural kinematics to the joint, with emphasis on eliminating both paradoxical anterior motion and reduced posterior femoral rollback. Given the design differences between anatomical and non-anatomical prostheses, it is important to investigate whether one technique provides superior kinematics when an anatomical design is used. We hypothesize that there will be no difference between the two techniques.

Methods

A total of 56 individuals were recruited to receive a Journey II prosthesis and randomized evenly to groups where the GB technique or MR technique is used. For all patients in the study, a series of radiostereometric analysis (RSA) images were acquired at 3-months post-operatively at different knee flexion angles, ranging in 20° increments from 0° to 120°. Model-based RSA software (RSACore, Leiden, Netherlands) was used to obtain the 3D positions and orientations of the femoral and tibial implant components, which were in turn used to obtain kinematic measures (contact locations and magnitude of excursion) for each condyle.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 55 - 55
1 Feb 2020
Broberg J Howard J Lanting B Vasarhelyi E Yuan X McCalden R Naudie D Teeter M
Full Access

Introduction

Despite improvements in the survivorship of total knee replacements (TKR) over the years, patient satisfaction following TKR has not improved, with approximately 20% of patients recording dissatisfaction with their new knee joint. It is unclear why many patients feel this way, but it may relate in part to implant designs that do not provide a “natural” feeling knee. Implant manufacturers continue to introduce new concepts for implant design, which are essential for reaching the goal of a “normal” knee after TKR surgery. The Journey II TKR (Smith & Nephew) was developed with this goal in mind. Its anatomical design attempts to mimic the normal knee joint structure to return more natural kinematics to the joint, with emphasis on eliminating both paradoxical anterior motion and reduced posterior femoral rollback. Our objective is to examine patients receiving the Journey II TKR to measure the knee joint contact kinematics of the Journey II TKR compared to a non-anatomically designed implant by the same manufacturer. We hypothesize that the Journey II TKR will have more natural contact kinematics that differ from the non-anatomically designed implant.

Methods

A total of 28 individuals were recruited to receive a Journey II TKR, matching an existing prior cohort with a non-anatomical design from the same manufacturer (Legion TKR, Smith & Nephew). For both groups, a series of radiostereometric analysis (RSA) images were acquired at different knee flexion angles, ranging in 20° increments from 0° to 120°. Model-based RSA software (RSACore, Leiden, Netherlands) was used to obtain the 3D positions and orientations of the femoral and tibial implant components, which were in turn used to obtain kinematic measures (contact locations and magnitude of excursion) for each condyle. Results from the Journey II TKR group at 3 months post-operation were compared to the 2-year post-operative measurements from the Legion TKR group.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 35 - 35
1 Oct 2018
MacDonald SJ Garach M Lanting B McCalden RW Vasarhelyi E Naudie D Howard J
Full Access

Introduction

The infection rate after total joint arthroplasty (TJA) has been shown to be 1–2% in multiple series and registry data. Irrigation, debridement, and polyethylene exchange (IDPE) is a common first line treatment in many cases of acute prosthetic joint infection (PJI). The reinfection rate in open IDPE procedures is variable with studies showing reinfection rates of 10–70% depending on various patient and microbial factors. Our pilot study aimed to determine if the bacterial load in infected total joints was sufficiently reduced by IDPE to allow for the use of post-debridement cultures as an independent marker of procedural success.

Methods

46 prosthetic joint infections underwent irrigation and debridement using 6L of normal saline and 3L of a normal saline and bacitracin mixture prior to the insertion of a new polyethylene liner. This protocol utilized a single equipment setup with all surgical members donning new gloves prior to polyethylene exchange. Between 3 and 5 intraoperative cultures were obtained both prior to and after debridement as per the surgeon's standard protocol. A two-tailed student's t-test was used to evaluate for any differences in the rate of positive culture between these two groups.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 10 - 10
1 Oct 2018
Howard JL Aljurayyan A Somerville L Teeter MG Vasarhelyi E Lanting B
Full Access

Introduction

Early functional recovery following total hip arthroplasty (THA) has the potential to increase patient satisfaction and reduce resource utilization. The direct anterior approach (DA) has been shown to provide earlier recovery compared to the direct lateral (DL) approach based on functional tests and outcome scores. There are limited studies that objectively evaluate functional recovery comparing the two approaches in the early post-operative period. Activity trackers have emerged as a valid tool to objectively quantify physical activity levels and potentially better assess functional status compared to commonly reported functional questionnaires. The purpose of this study is to measure physical activity levels in patients undergoing THA with the DA approach and compare these to THA with the direct lateral approach in the immediate postoperative period.

Methods

In a tertiary academic center we prospectively enrolled patients with primary OA that were eligible for a primary THA undergoing either the DA or the DL approach using the same prosthesis. Patients with comorbidities precluding them from ambulation, diagnoses of AVN or RA or undergoing bilateral THA were excluded. The number of steps walked per day were measured using wristband activity tracking technology for one week preoperatively, the first 2 weeks postoperatively and for 1 week leading up to their 6-week follow-up appointment. The University of California, Los Angeles (UCLA) activity score was also collected at the same two time points. Demographics were analyzed with descriptive statistics. A non-parametric Mann Whitney U test was used to determine whether a difference in physical activity levels exist between the DA and DL approach groups in the first 2 weeks and 6 weeks postoperatively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 30 - 30
1 Aug 2018
MacDonald S Garach M Lanting B McCalden R Vasarhelyi E Naudie D Howard J
Full Access

The infection rate after total joint arthroplasty (TJA) has been shown to be 1–2% in multiple series and registry data. Irrigation, debridement, and polyethylene exchange (IDPE) is a common first line treatment in many cases of acute prosthetic joint infection (PJI). The reinfection rate in open IDPE procedures is variable with studies showing reinfection rates of 10–70% depending on various patient and microbial factors. Our pilot study aimed to determine if the bacterial load in infected total joints was sufficiently reduced by IDPE to allow for the use of post-debridement cultures as an independent marker of procedural success.

46 prosthetic joint infections underwent irrigation and debridement using 6L of normal saline and 3L of a normal saline and bacitracin mixture prior to the insertion of a new polyethylene liner. This protocol utilized a single equipment setup with all surgical members donning new gloves prior to polyethylene exchange. Between 3 and 5 intraoperative cultures were obtained both prior to and after debridement as per the surgeon's standard protocol. A two-tailed student's t-test was used to evaluate for any differences in the rate of positive culture between these two groups.

Of all pre- and post-debridement cultures sampled 66.5% and 60.7% of cultures were positive respectively. No significant difference in the rate of positive intraoperative culture was found between pre-debridement and post-debridement groups (p = 0.52). In 32 of 46 (69%) cases there was no difference in the total number of positive cultures despite a thorough debridement.

Our data shows that open debridement of PJI does not provide a sterile environment, and post-debridement cultures should not be used as an independent marker of procedural success. The role of an irrigation and debridement to reduce the bacterial burden and potentiate the clearance of an infection is established but its efficacy is unclear, and the inability to create a post-debridement sterile environment is a concern.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 16 - 16
1 Aug 2018
McCalden R Ponnusamy K Marsh J Somerville L MacDonald S Naudie D Lanting B Howard J Vasarhelyi E
Full Access

The purpose of this study is to compare 90-day costs and outcomes for primary total hip arthroplasty (THA) patients between a non-obese (BMI 18.5–24.9) versus overweight (25–29.9), obese (30–34.9), severely-obese (35–39.9), morbidly-obese (40–44.9), and super-obese (45+) cohorts.

We conducted a retrospective review of a prospective institutional database of primary THA patients from 2006–2013, including patients with a minimum of three-year follow-up. Thirty-three super-obese patients were identified, and the other five cohorts were randomly selected in a 2:1 ratio (total n = 363). Demographics, 90-day outcomes (costs, reoperations, and readmissions), and outcomes after three years (revisions and change scores for SF12, HHS, and WOMAC) were collected. Costs were determined using unit costs from our institutional administrative data for all in-hospital resource utilization. Comparisons between the non-obese and other groups were made with Kruskal-Wallis tests for non-normal data and chi-square and Fisher's exact test for categorical data.

The 90-day costs in the morbidly-obese ($13,134 ± 7,250 mean ± standard deviation, p <0.01) and super-obese ($15,604 ± 6,783, p <0.01) cohorts were statistically significantly greater than the non-obese cohorts ($10,315 ± 1,848). Only the super-obese cohort had statistically greater 90-day reoperation and readmission rates than the non-obese cohort (18.2% vs 0%, p <0.01 and 21.2% vs 4.5%, p=0.02, respectively). In addition, reoperations and septic revisions after 3 years were greater in the super-obese cohort compared to the non-obese cohort 21.2% vs 3.0% (p = 0.01), and 18.2% vs 1.5% (p= 0.01), respectively. There were no other statistical differences between the other cohorts with the non-obese cohort at 90-days or after 3 years. Improvements in SF12, HHS, and WOMAC were comparable in all cohorts.

The 90-day costs of a primary total hip arthroplasty for morbidly-obese (BMI 40–44.9) and super-obese (BMI>45) are significantly greater than for non-obese patients, yet these patients have comparable improvements in outcome scores. Health care policies, when based purely on the economic impact of health care delivery, may place morbidly-obese and super-obese patients at risk of losing arthroplasty care, thereby denying them access to the comparable quality of life improvements.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 65 - 65
1 Mar 2017
Vasarhelyi E Petis S Lanting B Howard J
Full Access

Introduction

Total hip arthroplasty (THA) is the most effective treatment modality for severe arthritis of the hip. Patients report excellent clinical and functional outcomes following THA, including subjective improvement in gait mechanics. However, few studies in the literature have outlined the impact of THA, as well as surgical approach, on gait kinetics and kinematics.

Purpose

The purpose of this study was to determine the impact of surgical approach for THA on quantitative gait analysis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 10 - 10
1 Mar 2017
Sisko Z Teeter M Lanting B Howard J McCalden R Vasarhelyi E
Full Access

Purpose

Previous retrieval studies demonstrate increased tibial baseplate roughness leads to higher polyethylene backside wear in total knee arthroplasty (TKA). Micromotion between the polyethylene backside and baseplate is affected by the locking mechanism design and can further increase backside wear. This study's purpose was to examine modern locking mechanisms influence, in the setting of both polished and non-polished tibial baseplates, on backside tibial polyethylene damage and wear.

Methods

Five TKA models were selected with different tibial baseplate and/or locking mechanism designs. Six retrieval tibial polyethylenes from each TKA model were matched based on time in vivo (TIV), age at TKA revision, BMI, gender, number of times revised, and revision reason. Two observers visually assessed each polyethylene. Primary outcomes were visual damage scores, individual visual damage modes, and linear wear rates determined on micro-computed tomography (micro-CT) scan in mm/year. Demographics were compared by one-way ANOVA. Damage scores, damage modes, and linear wear were analyzed by the Kruskal-Wallis test and Dunn's multiple comparisons test.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 67 - 67
1 Mar 2017
Vasarhelyi E Weeks C Graves S Kelly L Marsh J
Full Access

Background

The management of the patella during primary total knee arthroplasty (TKA) is controversial. Despite the majority of patients reporting excellent outcomes following TKA, a common complaint is anterior knee pain. Resurfacing of the patella at the time of initial surgery has been proposed as a means of preventing anterior knee pain, however current evidence, including four recent meta-analyses, has failed to show clear superiority of patellar resurfacing. Therefore, the purpose of this study was to estimate the cost-effectiveness of patellar resurfacing compared to non-resurfacing in TKA.

Methods

We conducted a cost-effectiveness analysis using a decision analytic model to represent a hypothetical patient cohort undergoing primary TKA. Each patient will receive a TKA either with the Patella Resurfaced or Not Resurfaced. Following surgery, patients can transition to one of three chronic health states: 1) Well Post-operative, 2) Patellofemoral Pain (PFP), or 3) Serious Adverse Event (AE), which we have defined as any event requiring Revision TKA, including: loosening/lysis, infection, instability, or fracture (Figure 1). We obtained revision rates following TKA for both resurfaced and unresurfaced cohorts using data from the 2014 Australian Registry. This data was chosen due to similarities between Australian and North American practice patterns and patient demographics, as well as the availability of longer term follow up data, up to 14 years postoperative. Our effectiveness outcome for the model was the quality-adjusted life year (QALY). We used utility scores obtained from the literature to calculate QALYs for each health state. Direct procedure costs were obtained from our institution's case costing department, and the billing fees for each procedure. We estimated cost-effectiveness from a Canadian publicly funded health care system perspective. All costs and quality of life outcomes were discounted at a rate of 5%. All costs are presented in 2015 Canadian dollars.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 46 - 46
1 Mar 2017
Teeter M Howard J Vasarhelyi E Yuan X McCalden R Naudie D
Full Access

Background

Patient specific instrumentation (PSI) for total knee replacement (TKR) has demonstrated mixed success in simplifying the operation, reducing its costs, and improving limb alignment. Evaluation of PSI with tools such as radiostereometric analysis (RSA) has been limited, especially for cut-through style guides providing mechanical alignment. The primary goal of the present study was to compare implant migration following TKR using conventional and PSI surgical techniques, with secondary goals to examine whether the use of PSI reduces operative time, instrumentation, and surgical waste.

Methods

The study was designed as a prospective, randomized controlled trial of 50 patients, with 25 patients each in the PSI and conventional groups, powered for the RSA analysis. Patients in the PSI group received an MRI and standing 3-foot x-rays to construct patient-specific cut-through surgical guides for the femur and tibia with a mechanical alignment. All patients received the same posterior-stabilized implant, with marker beads inserted in the bone around the implants to enable RSA imaging. Intraoperative variables such as time, number of instrumentation trays used, and mass of surgical waste were recorded. Patients underwent supine RSA exams at multiple time points (2&6 weeks, 3&6 months and yearly) with 6 months data currently available. Migration of the tibial and femoral components was calculated using model-based RSA software. WOMAC, SF-12, EQ5D, and UCLA outcome measures were recorded pre-operatively and post-operatively.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 66 - 66
1 Mar 2017
MacLean C Lanting B Vasarhelyi E Naudie D McAuley J Howard J McCalden R MacDonald S
Full Access

Background

The advent of highly cross-linked polyethylene has resulted in improved wear rates and reduced osteolysis with at least intermediate follow-up when compared to conventional polyethylene. However, the role of alternative femoral head bearing materials in decreasing wear is less clear. The purpose of this study was to determine in-vivo polyethylene wear rates across ceramic, Oxinium, and cobalt chrome femoral head articulations.

Methods

A review of our institutional database was performed to identify patients who underwent a total hip arthroplasty using either ceramic or oxidized zirconium (Oxinium) femoral head components on highly cross-linked polyethylene between 2008 and 2011. These patients were then matched on implant type, age, sex and BMI with patients who had a cobalt chrome bearing implant during the same time period. RSA analysis was performed using the center index method to measure femoral head penetration (polyethylene wear). Secondary quality of life outcomes were collected using WOMAC and HHS Scores. Paired analyses were performed to detect differences in wear rate (mm/year) between the cobalt chrome cohorts and their matched ceramic and Oxinium cohorts. Additional independent group comparisons were performed by analysis of variance with the control groups collapsed to determine wear rate differences between all three cohorts.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 5 - 5
1 Feb 2017
Akindolire J Marsh J Howard J Lanting B Somerville L Vasarhelyi E
Full Access

Background

Total hip arthroplasty (THA) has become one of the most commonly performed elective procedures. Today, there are nearly 50 000 annual hospitalizations for hip replacement surgery in Canada. This number is projected to increase significantly with the aging population. Periprosthetic joint infection (PJI) is the 3rd leading cause of failure following THA and is reported to occur at an incidence of 1–3%. A two-stage revision THA is the current gold standard treatment and this has a tremendous economic impact on the healthcare system. The purpose of this study is to create an accurate cost estimate of two-stage revision THA and, in turn, evaluate the economic burden of PJI as it compares to primary THA in a Canadian healthcare context.

Methods

We conducted a retrospective review of primary THA cases and two-stage revision THA for PJI at our institution. Patients were matched for age and BMI. We recorded all costs associated with each procedure, including: OR time, equipment, length of hospital stay, readmission rates, and any other inpatient resource use. Unit costs were obtained using administrative data from the case costing department at London Health Sciences Centre. Billing fees associated with the procedure were obtained from the Ontario Schedule of Benefits. Descriptive statistics were used to summarize the demographic characteristics of patients, hospital costs and resource use data. Patients with PJI were compared to the matched cohort of primary THA using the t-test (for continuous variables), and the chi-square test (for categorical variables).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 1 - 1
1 Dec 2016
Zomar B Muir S Bryant D Vasarhelyi E Howard J Lanting B
Full Access

The purpose of our study was to prospectively examine early functional differences in gait between the direct anterior and direct lateral surgical approaches for total hip arthroplasty over the first three months postoperatively.

Forty participants were prospectively enrolled to either the direct anterior (20 patients) or direct lateral group (20 patients) based on their surgeon's expertise. Outcome measures were collected preoperatively at their preadmission appointment and postoperatively at discharge from the hospital, two weeks, six weeks and three months. We used the GAITRite® system to measure gait velocity, stride length, single-limb support and single-limb support symmetry. We also had participants complete the Timed Up and Go test and a series of questionnaires at each visit: WOMAC, SF-12, Harris Hip Score, and pain VAS.

Our primary outcome, gait velocity, was significantly greater in the direct anterior group at discharge and six weeks postoperatively with adjusted mean differences of 0.12m/s and 0.17m/s respectively. Single-limb support symmetry was also significantly better in the direct anterior group at two weeks, six weeks and three months with adjusted mean differences of 0.10, 0.09 and 0.04 respectively. The direct anterior group also had significantly shorter times to complete the Timed Up and Go test at two and six weeks with adjusted mean differences of −9.02s and −2.64s. There were no differences between the groups at any time point for the WOMAC, SF-12, Harris Hip Score, or pain VAS.

Preliminary results of our expertise-based study have found the direct anterior approach to total hip arthroplasty offers better early functional outcomes than the direct lateral approach.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 55 - 55
1 Dec 2016
Lanting B Thoren J Yuan X McCalden R McAuley J MacDonald S Vasarhelyi E Howard J Naudie D Teeter M
Full Access

Adequate fixation of implant components is an important goal for all arthroplasty procedures. Aseptic loosening is one of the leading causes of revision surgery in total knee arthroplasty. Radiostereometric analysis (RSA) is an imaging technique to measure implant migration, with established migration thresholds for well-fixed, at risk, and unacceptably migrating components. The purpose of the present study was to examine the long-term fixation of a cemented titanium fixed bearing polished tibial baseplate.

Patients enrolled in a previous two-year prospective trial were recalled at ten years. All patients received a cemented, posterior-stabilised total knee replacement of the same design implanted by one of three surgeons. Of the original 35 patients, 16 were available for long-term follow-up, with one patient lost to follow-up, nine patients deceased, and a further nine patients unwilling to return to the clinic. Each patient underwent RSA imaging in a supine position using a conventional RSA protocol. Migration of the tibial component in all planes as well as maximum total point motion (MTPM) was compared between all time points (baseline, six weeks, three months, six months, one year, two years) up to the ten year follow-up visits. Outcome scores including the Knee Society Score (KSS), WOMAC, SF-12, and UCLA Activity Score were recorded.

At ten years, the mean migrations of the tibial component were less than 0.1 mm and 0.1 degree in all planes relative to the post-operative RSA exam. There was no significant difference in tibial component migration between time points. However, MTPM increased significantly over time (p = 0.002), from 0.23 ± 0.18 mm at six weeks to 0.42 ± 0.20 mm at ten years. At one year, 13 patients had an acceptable MTPM level, three patients had an ‘at risk’ level, and no patient had an ‘unacceptable’ level. No patients were revised at ten years. WOMAC and KSS were significantly improved (p < 0.0001) at the latest follow-up compared to pre-operatively, but there was no difference in SF-12. The median UCLA Activity Score at latest follow-up was six (range, two to eight).

The tibial baseplate demonstrated solid fixation at ten years. No patients had an unacceptable MTPM level at one year and no patients were revised at ten years, supporting the use of RSA to predict long-term loosening risk. The low level of tibial baseplate migration found in the present study correlates to the low rate of revision for this implant as reported in individual studies and in joint replacement registries.