header advert
Results 1 - 3 of 3
Results per page:
Bone & Joint Open
Vol. 2, Issue 7 | Pages 476 - 485
8 Jul 2021
Scheerlinck T De Winter E Sas A Kolk S Van Gompel G Vandemeulebroucke J

Aims

Hip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an anatomical and medialized hip rotation centre.

Methods

Using 3D templating software in 49 CT scans of non-deformed femora, we virtually implanted: 1) small uncemented calcar-guided stems with two offset options (Optimys, Mathys), 2) uncemented straight stems with two offset options (Summit, DePuy Synthes), 3) cemented undersized stems (Exeter philosophy) with three offset options (CPT, ZimmerBiomet), and 4) cemented line-to-line stems (Kerboul philosophy) with proportional offsets (Centris, Mathys). We measured the distance between the templated and the anatomical and 5 mm medialized hip rotation centre.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 43 - 43
1 Dec 2020
Sas A Sermon A van Lenthe GH
Full Access

Prophylactic treatment is advised for metastatic bone disease patients with a high risk of fracture. Clinicians face the task of identifying these patients with high fracture risk and determining the optimal surgical treatment method. Subject-specific finite element (FE) models can aid in this decision process by predicting the mechanical effect of surgical treatment. In this study, we specifically evaluated the potential of FE models to simulate femoroplasty, as uncertainty remains whether this prophylactic procedure provides sufficient mechanical strengthening to the weight-bearing femur.

In eight pairs of human cadaveric femurs artificial metastatic lesions were created. In each pair, an identical defect was milled in the left and right femur. Four pairs received a spherical lesion in the neck and the other four an ellipsoidal lesion in the intertrochanteric region, each at the medial, superior/lateral, anterior and posterior side, respectively. One femur of each pair was augmented with polymethylmethacrylate (5–10 ml), while the contralateral femur was left untreated. CT scans were made at three different time points: from the unaffected intact femurs, the defect femurs with lesion and the augmented femurs. Bone strength was measured by mechanical testing until failure in eight defect and eight augmented femurs. Nonlinear CT-based FE models were developed and validated against the experimentally measured bone strength. Subsequently, the validated FE model was applied to the available CT scans for the three different cases: intact (16 scans), defect (16) and augmented (8). The FE predicted strength was compared for the three different cases.

The FE models predicted the experimental bone strength with a strong correspondence, both for the defect (R2 = 0.97, RMSE= 0.75 kN) and the augmented femurs (R2 = 0.90, RMSE = 0.98 kN). Although all lesions had a “moderate” to “high” risk for fracture according to the Mirels’ scoring system (score 7 or 8), three defect femurs did not fracture through the lesion (intertrochanteric anterior, lateral and posterior), indicating that these lesions did not act as a critical weak spot. In accordance with the experimental findings, the FE models indicated almost no reduction in strength between the intact and defect state for these femurs (0.02 ± 0.1%). For the remaining “critical” lesions, bone strength was reduced with 15.7% (± 14.9%) on average. The largest reduction was observed for lesions on the medial side (up to 43.1%). For the femurs with critical lesions, augmentation increased bone strength with 29.5% (± 29.7%) as compared to the defect cases, reaching strength values that were 2.5% (± 3.7%) higher than the intact bone strength.

Our findings demonstrate that FE models can accurately predict the experimental bone strength before and after augmentation, thereby enabling to quantify the mechanical benefit of femoroplasty. This way FE models could aid in identifying suitable patients for whom femoroplasty provides sufficient increase in strength. For all lesions evaluated in this study, femoroplasty effectively restored the initial bone strength. Yet, additional studies on larger datasets with a wide variation of lesion types are required to confirm these results.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 11 - 11
1 Apr 2018
Sas A Kolk S Pellikaan P Scheerlinck T Van Lenthe H
Full Access

Introduction

Although total hip arthroplasty is a very successful operation, complications such as: dislocation, aseptic loosening, and periprosthetic fracture do occur. These aspects have been studied in large populations for traditional stem designs, but not for more recent short stems. The design rationale of short stems is to preserve bone stock, without compromising stability. However, due to their smaller bone contact area, high peak stresses and areas of stress shielding could appear in the proximal femur, especially in the presence of atypical bone geometries. In order to evaluate this aspect, we quantified the stress distribution in atypical proximal femurs implanted with a commercially available calcar guided short stem.

Methods

Geometrical shape variations in neck-shaft angle (NSA), neck-length (NL) and anteversion (AV), were determined three-dimensionally in the Mimics Innovation Suite (Materialise N.V., Leuven, Belgium) from a CT dataset of 96 segmented femurs. For each shape variation, the femurs that had the two lowest, two average and two highest values were included (18 femurs). Using scripting functionality in Mimics, CAD design files of the calcar guided Optimys short stem (Mathys, Bettlach, Switzerland) were automatically sized and aligned to restore the anatomical hip rotation center. Stem size and position were manually corrected by an orthopedic surgeon before finite element (FE) models were constructed using a non-manifold assembly approach (Figure 1). Material properties were estimated from the CT dataset and loads representing walking and stair climbing were applied [1]. Stress-shielding was evaluated by the change in average strain energy density pre- and post-operatively in three different regions (calcar, midstem, tip) each being subdivided in four quarters (medial, lateral, anterior, posterior) (Figure 2).