header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 24 - 24
2 Jan 2024
Nolan L Mahon J Mirdad R Alnajjar R Galbraith A Kaar K
Full Access

Total shoulder arthroplasty (TSA) and Reverse Total shoulder arthroplasty (RSA) are two of the most performed shoulder operations today. Traditionally postoperative rehabilitation included a period of immobilisation, protecting the joint and allowing time for soft tissue healing. This immobilisation period may significantly impact a patient's quality of life (Qol)and ability to perform activities of daily living (ADL's). This period of immobilisation could be safely avoided, accelerating return to function and improving postoperative QoL.

This systematic review examines the safety of early mobilisation compared to immobilisation after shoulder arthroplasty focusing on outcomes at one year.

Methods

A systematic review was performed as per the PRISMA guidelines. Results on functional outcome and shoulder range of motion were retrieved.

Six studies were eligible for inclusion, resulting in 719 patients, with arthroplasty performed on 762 shoulders, with information on mobilisation protocols on 736 shoulders (96.6%) and 717 patients (99.7%). The patient cohort comprised 250 males (34.9%) and 467 females (65.1%). Of the patients that successfully completed follow-up, 81.5% underwent RSA (n = 600), and 18.4% underwent TSA (n = 136). Overall, 262 (35.6%) patients underwent early postoperative mobilisation, and 474 shoulders were (64.4%) immobilised for a length of time. Immobilised patients were divided into three subgroups based on the period of immobilisation: three, four, or six weeks. There were 201 shoulders (27.3%) immobilised for three weeks, 77 (10.5%) for four weeks and 196 (26.6%) for six weeks. Five of the six manuscripts found no difference between clinical outcomes at one year when comparing early active motion versus immobilisation after RSA or TSA.

Early mobilisation is a safe postoperative rehabilitation pathway following both TSA and RSA. This may lead to an accelerated return to function and improved quality of life in the postoperative period.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 143 - 143
1 Nov 2021
McCarthy C Mahon J Sheridan G Welch-Phillips A O'Byrne J Kenny P
Full Access

Introduction and Objective

Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years.

Materials and Methods

A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively.