Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 17 - 17
3 Mar 2023
Warder H Semple A Johnson DS
Full Access

A hip fracture represents the extreme end of osteoporosis, placing a significant burden on secondary care, society, and the individual patient. The National Hip Fracture Database (NHFD) reports each hospital's attainment of the BPT with other measures, along with reporting outcomes. There is clearly wide variability in provision of orthogerriatrician (OG) services across the dataset. Unfortunately, despite overwhelming evidence that provision of an OG service is of benefit, it is presently challenging to recruit to this important specialty within the UK.

Publicly available reports from the NHFD were obtained for each of the 177 participating hospitals for 2017. This was matched with information held within the annual NHFD Facilities Audit for the same period, which include hours of OG support for each hospital. This information was combined with a Freedom of Information request made by email to each hospital for further details concerning OG support. The outcome measures used were Length of Stay (LoS), mortality, and return to usual residence. Comparison was made with provision of OG services by use of Pearson's correlation coefficient. In addition, differences in services were compared between the 25% (44) hospitals delivering outcomes at the extremes for each measure.

Attainment of BPT correlated fairly with LoS (−0.48) and to less of a degree with mortality (−0.1) and return home (0.05). Perioperative medical assessment contributed very strongly with BPT attainment (0.75). In turn perioperative medical assessment correlated fairly with LoS (−0.40) and mortality (−0.23) but not return home (0.02). Provision of perioperative medical assessment attainment was correlated fairly with total OG minutes available per new patient (0.22), total OG minutes available per patient per day (0.29) and number of days per week of OG cover (0.34); with no link for number of patients per orthogeriatrician (0.01). Mortality for the best units were associated with 30% more consultant OG time available per patient per day, and 51% more OG time available per patient. Units returning the most patients to their usual residence had little association with OG time, although had 59% fewer patients per OG, the best units had a 19% longer LoS. For all three measures results for the best had on average 0.5 days per week better routine OG access.

There is no doubt that good quality care gives better results for this challenging group of patients. However, the interaction of BPT, other care metrics, level of OG support and patient factors with outcomes is complex. We have found OG time available per patient per day appears to influence particularly LoS and mortality. Options to increase OG time per patient include reducing patient numbers (ensuring community osteoporosis/falls prevention in place, including reducing in-patient falls); increasing OG time across the week (employing greater numbers/spreading availability over 7 days per week); and reducing LoS. A reduction in LoS has the largest effect of increasing OG time, and although it is dependent on OG support, it is only fairly correlated with this and many other factors play a part, which could be addressed in units under pressure.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 424 - 424
1 Sep 2009
Khan WS Anand S Tew S Andrew JG Johnson DS Hardingham TE
Full Access

There is an ever-increasing clinical need for the regeneration and replacement of tissue to replace soft tissue lost due to trauma, disease and cosmetic surgery. A potential alternative to the current treatment modalities is the use of tissue engineering applications using mesenchymal stem cells that have been identified in many tissue including the infrapatellar fat pad. In this study, stem cells isolated from the infrapatellar fat pad were characterised to ascertain their origin, and allowed to undergo adipogenic differentiation to confirm multilineage differentiation potential.

The infrapatellar fat pad was obtained from total knee replacement for osteoarthritis. Cells were isolated and expanded in monolayer culture. Cells at passage 2 stained strongly for CD13, CD29, CD44, CD90 and CD105 (mesenchymal stem cell markers). The cells stained poorly for LNGFR and STRO1 (markers for freshly isolated bone marrow derived stem cells), and sparsely for 3G5 (pericyte marker). Staining for CD34 (haematopoetic marker) and CD56 (neural and myogenic lineage marker) was negative.

For adipogenic differentiation, cells were cultured in adipogenic inducing medium consisting of basic medium with 10ug/ml insulin, 1uM dexamthasone, 100uM indomethacin and 500uM 3-isobutyl-1-methyl xanthine. By day 16, many cells had lipid vacuoles occupying most of the cytoplasm. On gene expression analyses, the cells cultured under adipogenic conditions had almost a 1,000 fold increase in expression of peroxisome proliferator-activated receptor gamma-2 (PPAR gamma-2) and 1,000,000 fold increase in expression of lipoprotein lipase (LPL). Oil red O staining confirmed the adipogenic nature of the observed vacuoles and showed failure of staining in control cells.

Our results show that the human infrapatellar fat pad is a viable potential autogeneic source for mesenchymal stem cells capable of adipogenic differentiation as well as previously documented ostegenic and chondrogenic differentiation. This cell source has potential use in tissue engineering applications.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 422 - 422
1 Sep 2009
Fox AE Johnson DS Havely D Cook GE
Full Access

Purpose of Study: We aimed to reduce the work intensity involved in auditing high volume procedures (eg knee arthroscopy) by developing and validating a tool which uses routinely acquired hospital data, to target those patients most likely to have developed an undesirable post-operative outcome.

Methodology: The work was a collaboration effort between the Orthopaedic and Clinical Effectiveness departments. During the period 1997–2003, 2926 elective knee arthroscopies were identified as having been performed in our unit. Linkage of routinely collected data held on the hospital’s computerized Patient Administrative System (PAS), hospital theatre system and A& E system, with data from the Office of National Statistics concerning death, high-lighted 183 cases (Core group) meeting one or more of four indicators: readmission < 28 days, return to theatre < 28 days, return to A& E < 28 days, and length of stay 4+ days (Graph 1). The accuracy of the tool to identify undesirable post-operative outcomes was made comparing the Core group and a Random sample (N=240).

Results: Accuracy of OPCS-4 coding for arthroscopic procedure performed was 77.1% in the core group and 96.4% in the random sample. The new tool yielded a sensitivity of 38% and specificity of 95%. Where major complications were concerned the sensitivity rose to 100%. For major complications the proposed model indicated a 0.6% complication rate vs 0.5% actual rate. For minor complications the proposed model indicated a 1.4% rate vs 3.8% actual rate. Overall complication rate within our unit was comparable to the published literature.

Conclusion: The tool has achieved its aim of identifying all major complications and undesirable events, along with many minor complications. As the tool identifies additional information it must be used as an aid to identifying patients for case note review. However, in our study it reduced the number needed to less than 7% of the total.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 582 - 582
1 Aug 2008
Khan WS Jones RK Nokes L Johnson DS
Full Access

Introduction: There has been an increasing use of orthotic knee braces in the management of knee injuries. To ensure the biomechanics of the knee are not adversely affected, it is important that orthotic knee braces accurately provide the desired angle of immobilisation. The objective of our study was to measure the actual knee flexion angles for a lockable orthotic knee brace, and measure the resulting knee flexion moment.

Materials and methods: Eight healthy male volunteers participated in the study looking at six different types of knee immobilisation: locked in 0, 10, 20, 30 degrees of knee flexion, with the brace unlocked, and without a brace. Force and 3-dimensional motion data were collected using a single Kistler force plate and an eight-camera Qualisys ProReflex motion analysis system.

Results: The kinematic knee flexion angles were significantly different when compared with the angles set at the orthotic knee brace for 0 degrees (p=0.001) and 10 degrees (p=0.011). The kinematic knee flexion angle when no brace was used was significantly different from the angle for the unlocked orthotic knee brace (p= 0.003). The knee flexion moment was directly proportional to the knee flexion angle. There was a statistically significant difference between the knee flexion moment for the six types of immobilisation (p< 0.001).

Discussion: The knee flexion angles measured using the kinematic data did not always correspond with the angle set at the orthotic knee brace. These findings highlight inadequacies in the design of lockable orthotic knee braces, especially at low flexion angles of 0 and 10 degrees. The resulting higher actual knee flexion angles were associated with greater knee flexion moments and joint reaction forces at the tibiofemoral and patellofemoral joints. This can, at best result in increased energy expenditure and decreased agility, and at worse potentially augment injuries to the knee.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 6 - 6
1 Mar 2008
Bonshahi A Parsons SJ Helm AT Johnson DS Smith RB
Full Access

The study was established to assess the long-term results and differences between autogenous and synthetic anterior cruciate ligament (ACL) reconstruction.

We randomised 50 patients into 2 groups: 26 (52%) underwent reconstruction with middle third patellar tendon graft (PTG) harvested using the ‘Graftologer’ (Neoligaments) and 24 (48%) underwent reconstruction with the Leeds-Keio ligament (LK).

Subjective knee function was assessed using the Lysholm score, Tegner activity score, IKDC grading, and clinical assessment of anterior knee pain. Laxity was tested clinically, including anterior draw at 20° (Lachman), pivot shift, and arthrometric measurements using the Stryker laxometer.

At five years we have noted no significant difference in Lysholm scoring and Pivot shift between the LK group and patellar tendon group. But there was a significant difference in Tegner activity level and IKDC activity scores with PTG faring better at five years. There is no significance difference in anterior knee symptoms between the groups.

Conclusion: Due to the success of PTG/Hamstring in routine primary ACL reconstruction there does not seem to be a role for artificial ligaments. However, if we just look at functional outcome and patient satisfaction, LK patients seem to be doing as well as PTG at five years. So, there may be a place for the Leeds Keio graft where autologous tissue is unavailable.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 911 - 914
1 Jul 2007
Khan WS Nokes L Jones RK Johnson DS

We describe the influence of the angle of immobilisation during partial weight-bearing on the forces across the extensor mechanism of the knee. Gait analysis was performed on eight healthy male subjects with the right knee in an orthotic brace locked at 0°, 10°, 20° and 30°, with the brace unlocked and also without a brace. The ground reaction force, the angle of the knee and the net external flexion movement about the knee were measured and the extensor mechanism force was calculated.

The results showed a direct non-linear relationship between the angle of knee flexion and the extensor mechanism force. When a brace was applied, the lowest forces occurred when the brace was locked at 0°. At 30° the forces approached the failure strength of some fixation devices. We recommend that for potentially unstable injuries of the extensor mechanism, when mobilising with partial weight-bearing, the knee should be flexed at no more than 10°.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 440 - 440
1 Apr 2004
Bonshahi A Parsons SJ Helm AT Johnson DS Smith RB
Full Access

The study was established to assess the long-term results and differences between autogenous and synthetic anterior cruciate ligament (ACL) reconstruction.

We randomised 50 patients into 2 groups: 26 (52%) underwent reconstruction with middle third patellar tendon graft (PTG) harvested using the ‘ Graftologer ‘ (Neoligaments), and 24 (48%) underwent reconstruction with the Leeds-Keio ligament (LK).

Subjective knee function was assessed using the Lysholm score, Tegner activity score, IKDC grading, and clinical assessment of anterior knee pain. Laxity was tested clinically, including anterior draw at 20° (Lachman), pivot shift, and arthrometric measurements using the Stryker laxometer.

At five years we have noted a slight reduction in Lysholm scoring in the LK group, as well as reduced Tegner activity level. Pivot shift and laxity were significantly greater in the LK group.

Compared with earlier results, which showed little subjective difference between the groups, the autogenous PTG group show more sustainable long-term results than the synthetic (LK) group. There is no significant difference in anterior knee symptoms between the groups.


Aim: We conducted a prospective, randomised study of 50 patients, 40 (80%) male and 10 (20%) female, with anterior cruciate ligament (ACL) rupture to compare the results of ligament reconstruction by middle third patellar tendon graft (M) or synthetic Leeds-Keio (LK) ligament.

Method: The patients were randomised into two groups. 26 (52%) underwent PTG repair and 24 (48%) LK repair. Subjective knee function was classified using the Lysholm score, Tegner activity score and IKDC grading. Laxity was tested by clinical examination including anterior draw, pivot shift and arthrometric measurements using the Stryker Laxometer (Stryker Corporation, Kalamazoo, Michigan, USA).

Results: We present the early (two to five-year follow-up) results of this on-going trial. There was no statistical difference between the two groups in activity levels, both pre-injury and current. However, both pivot shift and anterior laxity were significantly greater in the LK group at two years and greater.

Discussion: While the LK group did develop significantly greater laxity, it is demonstrated that the functional outcome is not affected. We conclude therefore that if the results of surgery were to be based on a functional outcome rather than objective measurements of laxity, it would seem logical that the LK is an acceptable alternative to autogenous PTG.

However whilst function appears to be as good the less successful objective criteria do suggest reservations for the long term results of the Leeds-keio graft.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 160 - 160
1 Jul 2002
Johnson DS Macleod A Smith RB
Full Access

The aim of this trial was to assess the clinical examination findings commonly used for the ACL deficient knee.

For reliability testing and criterion validation 102 patients with ACL injuries were assessed by a single observer, 35 by a second observer and 47 again by the initial observer. For construct and criterion validation 30 patients were assessed pre-operatively and a mean of 1.7 years after ACL reconstruction. The Lysholm 11, Tegner and Cincinnati outcome measures were assessed along with instrumented knee laxity (Stryker test), the one hop test (OHT) and graded tests (including anterior draw, Lachman test, quality of end point, and pivot shift test).

The outcome measures were found to be reliable except the Cincinnati system. All examination findings were of unsatisfactory reliability, with the exception of the OHT and the Stryker test. Construct validation revealed a significant improvement in all outcome measure scores and examination findings following ACL reconstruction. Criterion validation revealed that of the examination findings only the OHT had a satisfactory correlation with the symptom of giving way and the Lysholm/Tegner measures. Comparison of the difference between the desired and actual Tegner activity levels with the examination findings revealed an improvement in all levels of correlation.

With the exception of the OHT, the clinical examination findings used for the ACL deficient knee are unreliable and correlate poorly with the functional outcome of the patient. They may, however, have some benefit in assessment of deficiency of the anatomical structures and the findings should be presented individually, rather than forming part of the functional assessment of the patient.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 162 - 162
1 Jul 2002
Zenios M Johnson DS Clayson AD Kay P
Full Access

The aim of this randomised prospective study was to establish whether the use of knee splints following total knee replacement is necessary.

The study included 81 patients undergoing total knee replacement who were randomised into a ‘splint’ and a ‘no splint’ group postoperatively. Patients in the ‘splint’ group had their knee splinted in extension in the early post-operative period but the splint was removed for the patients to do exercise. Splintage was completely removed when the patient could straight leg raise. Patients in the ‘no splint’ group had a wool and crepe bandage applied around their knee and allowed to fully mobilise from the first postoperative day. The following parameters were recorded: The range of movement preoperatively, 5 days post-operatively and 6 weeks postoperatively; the length of time to straight leg raise; the blood drained from the wound. and the amount of postoperative analgesia required.

Using the unpaired 2 tailed t-test it was found that patients in the four ‘no splint’ group achieved significantly greater flexion at 5 days and 6 weeks post-operatively but drained significantly more blood from the wound. Transfusion requirements were similar in the two groups. There was no other significant difference in the parameters measured between the two groups.

In conclusion we found no evidence to advocate the use of knee splints following total knee arthroplasty.