header advert
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1405 - 1413
1 Aug 2021
Ogura K Fujiwara T Morris CD Boland PJ Healey JH

Aims

Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model.

Methods

We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation.


Aims

Time to treatment initiation (TTI) is generally defined as the time from the histological diagnosis of malignancy to the initiation of first definitive treatment. There is no consensus on the impact of TTI on the overall survival in patients with a soft-tissue sarcoma. The purpose of this study was to determine if an increased TTI is associated with overall survival in patients with a soft-tissue sarcoma, and to identify the factors associated with a prolonged TTI.

Methods

We identified 23,786 patients from the National Cancer Database who had undergone definitive surgery between 2004 and 2015 for a localized high-grade soft-tissue sarcoma of the limbs or trunk. A Cox proportional hazards model was used to examine the relationship between a number of factors and overall survival. We calculated the incidence rate ratio (IRR) using negative binomial regression models to identify the factors that affected TTI.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 398 - 404
1 Feb 2021
Christ AB Fujiwara T Yakoub MA Healey JH

Aims

We have evaluated the survivorship, outcomes, and failures of an interlocking, reconstruction-mode stem-sideplate implant used to preserve the native hip joint and achieve proximal fixation when there is little residual femur during large endoprosthetic reconstruction of the distal femur.

Methods

A total of 14 patients underwent primary or revision reconstruction of a large femoral defect with a short remaining proximal femur using an interlocking, reconstruction-mode stem-sideplate for fixation after oncological distal femoral and diaphyseal resections. The implant was attached to a standard endoprosthetic reconstruction system. The implant was attached to a standard endoprosthetic reconstruction system. None of the femoral revisions were amenable to standard cemented or uncemented stem fixation. Patient and disease characteristics, surgical history, final ambulatory status, and Musculoskeletal Tumor Society (MSTS) score were recorded. The percentage of proximal femur remaining was calculated from follow-up radiographs.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 280 - 284
1 Mar 2020
Ogura K Boland PJ Fabbri N Healey JH

Aims

Although internal hemipelvectomy is associated with a high incidence of morbidity, especially wound complications, few studies have examined rates of wound complications in these patients or have identified factors associated with the consequences. The present study aimed to: 1) determine the rate of wound and other complications requiring surgery after internal hemipelvectomy; and 2) identify factors that affect the rate of wound complications and can be used to stratify patients by risk of wound complications.

Methods

The medical records of 123 patients undergoing internal hemipelvectomy were retrospectively reviewed, with a focus on both overall complications and wound complications. Logistic regression analyses were performed to examine the association between host, tumour, and surgical factors and rates of postoperative wound complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 78 - 83
1 Jan 2008
Schwab JH Healey JH Athanasian EA

We describe a consecutive series of five patients with bone or soft-tissue sarcomas of the elbow and intra-articular extension treated by complex soft tissue, allograft bone and prosthetic joint replacement after wide extra-articular en bloc excision. All had a pedicled myocutaneous latissimus dorsi rotation flap for soft-tissue cover and reconstruction of the triceps. Wide negative surgical margins were obtained in all five patients. No local wound complications or infections were seen. There were no local recurrences at a mean follow-up of 60 months (20 to 105). The functional results were excellent in four patients and good in one. Longer term follow-up is necessary to confirm the durability of the elbow reconstruction.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1658 - 1662
1 Dec 2005
Manoso MW Boland PJ Healey JH Tyler W Morris CD

A retrospective analysis was performed of eight patients with an open triradiate cartilage, who underwent resection for osteosarcoma and reconstruction of the proximal femur with a hemiarthroplasty, in order to identify changes of acetabular development. An analysis of the centre-edge angle, teardrop-to-medial prosthesis distance, superior joint space, teardrop-to-superior prosthesis distance, degree of lateral translation, and arthritic changes, was performed on serial radiographs. The median age at the time of the initial surgery was 11 years (5 to 14).

All patients developed progressive superior and lateral migration of the prosthetic femoral head. Following hemiarthroplasty in the immature acetabulum, the normal deepening and enlargement of the acetabulum is arrested. The degree of superior and lateral migration of the prosthetic head depends on the age at diagnosis and the length of follow-up.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 99 - 99
1 Feb 2003
Shannon FJ DiResta G Ottaviano D Castro A Healey JH Boland PJ
Full Access

To evaluate and compare the stability of an anterior cement construct following total spondylectomy for meta-static disease against alternative stabilization techniques.

After intact analysis of ten cadaveric spines (T9–L3), a T12 spondylectomy was performed. Three reconstruction techniques were tested for their ability to restore stiffness to the specimen using non-destructive tests:

1) multilevel posterior pedicle screw instrumentation (PPSI) from T10–L2 {MPI}, 2) anterior instrumentation from T11–L1 with PPSI {AMPI}, and 3) anterior cement and pins construct (T12) with PPSI {CMPI}.

Circumferential stabilization {AMPI, CMPI} restored stiffness to a level of the intact spine. CMPI provided more stability to the specimen than AMPI. MPI alone did not restore stiffness to the intact level.

Circumferential reconstruction using an anterior cement construct following total spondylectomy is biomechanically superior to posterior stabilisation alone.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 135 - 135
1 Feb 2003
Shannon FJ DiResta G Ottaviano D Castro A Healey JH Boland PJ
Full Access

Introduction: Patients with spinal metastases often have patterns of disease requiring both an anterior and posterior surgical decompression and stabilisation. Subtotal spondylectomy and circumferential stabilisation can be safely performed via a single posterior transpedicular approach. Polymethyl-methacrylate bone cement (PMMA) has been widely used in spinal column reconstruction with mixed results. PMMA is a potential means for local drug delivery in the prevention of locally recurrent disease. The biomechanical characteristics of anterior reconstruction using PMMA have not been adequately evaluated.

Purpose: To evaluate the stability of an anterior cement construct following total spondylectomy and to compare this reconstruction against alternative stabilisation techniques.

Methods: Ten fresh-frozen human cadaveric spines (T9-L3) were used. After intact analysis, a total spondylectomy was performed at T12. Three potential reconstruction techniques were tested for their ability to restore stiffness to the specimen: (1) multi-level posterior pedicle screw instrumentation from T10-L2 {MP1} [Depuy Acromed], (2) anterior instrumentation [ATL Z-plate II™, Medtronic, Sofamor Danek Instruments] and rib graft at T11-L1 with multi-level posterior instrumentation from T10-L2 {AMPI}, and (3) anterior cement [Simplex P] and pins construct (T12) with multi-level posterior instrumentation from T10-L2 {CMPI}. Each of the three potential reconstruction techniques was tested on each specimen in random order. Non-destructive testing was performed under load control. The specimen was positioned vertically for axial compression and torsion testing, and horizontal for flexion/extension and lateral bending tests. A customised jig was manufactured for this latter purpose.

Results: Only circumferential stabilisation techniques (AMPI, CMPI) restored stiffness to a level equivalent or higher to that of the intact spine in all loading modes (p< 0.05). CMPI provided more stability to the specimen than AMPI in compression and flexion testing (p< 0.05). Posterior instrumentation alone (MPI) did not restore stiffness to the intact level in compression and flexion testing (p< 0.005).

Conclusions: Circumferential reconstruction using an anterior cement construct provides equal or more stability than the intact spine in all testing modes. Posterior stabilisation alone is an inadequate method of reconstruction following total spondylectomy. PMMA has the advantage over traditional anterior reconstruction techniques in that it can be inserted using a single posterior approach and offers the potential value of local drug delivery.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 666 - 669
1 Jul 2000
Kawai A Backus SI Otis JC Inoue H Healey JH

We analysed the gait characteristics of 15 patients with prosthetic reconstruction of the proximal femur after resection of a malignant bone tumour using stride analysis and measurement of oxygen consumption. Compared with normal volunteers their gait was slower, with less cadence and reduced stride length. The mean net energy cost of free walking was 141% of normal. The degree of asymmetry of the single-limb support time correlated with the free-walking velocity and the net energy cost. If they used a single cane the subjects walked with less cadence, longer stride length, and prolonged single-limb support times. The net energy cost of walking and asymmetry of the single-limb support time had a negative correlation with the strength of the hip abductor muscles. Their walking performance was better than that of six subjects who had hip disarticulation.