BIOMECHANICAL ANALYSIS OF ANTERIOR PMMA RECONSTRUCTION FOLLOWING TOTAL SPONDYLECTOMY FOR METASTATIC DISEASE



Abstract

Introduction: Patients with spinal metastases often have patterns of disease requiring both an anterior and posterior surgical decompression and stabilisation. Subtotal spondylectomy and circumferential stabilisation can be safely performed via a single posterior transpedicular approach. Polymethyl-methacrylate bone cement (PMMA) has been widely used in spinal column reconstruction with mixed results. PMMA is a potential means for local drug delivery in the prevention of locally recurrent disease. The biomechanical characteristics of anterior reconstruction using PMMA have not been adequately evaluated.

Purpose: To evaluate the stability of an anterior cement construct following total spondylectomy and to compare this reconstruction against alternative stabilisation techniques.

Methods: Ten fresh-frozen human cadaveric spines (T9-L3) were used. After intact analysis, a total spondylectomy was performed at T12. Three potential reconstruction techniques were tested for their ability to restore stiffness to the specimen: (1) multi-level posterior pedicle screw instrumentation from T10-L2 {MP1} [Depuy Acromed], (2) anterior instrumentation [ATL Z-plate II™, Medtronic, Sofamor Danek Instruments] and rib graft at T11-L1 with multi-level posterior instrumentation from T10-L2 {AMPI}, and (3) anterior cement [Simplex P] and pins construct (T12) with multi-level posterior instrumentation from T10-L2 {CMPI}. Each of the three potential reconstruction techniques was tested on each specimen in random order. Non-destructive testing was performed under load control. The specimen was positioned vertically for axial compression and torsion testing, and horizontal for flexion/extension and lateral bending tests. A customised jig was manufactured for this latter purpose.

Results: Only circumferential stabilisation techniques (AMPI, CMPI) restored stiffness to a level equivalent or higher to that of the intact spine in all loading modes (p< 0.05). CMPI provided more stability to the specimen than AMPI in compression and flexion testing (p< 0.05). Posterior instrumentation alone (MPI) did not restore stiffness to the intact level in compression and flexion testing (p< 0.005).

Conclusions: Circumferential reconstruction using an anterior cement construct provides equal or more stability than the intact spine in all testing modes. Posterior stabilisation alone is an inadequate method of reconstruction following total spondylectomy. PMMA has the advantage over traditional anterior reconstruction techniques in that it can be inserted using a single posterior approach and offers the potential value of local drug delivery.