header advert
Results 1 - 20 of 23
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 71 - 71
11 Apr 2023
Pelegrinelli A Kowalski E Ryan N Dervin G Moura F Lamontagne M
Full Access

The study compared thigh-shank and shank-foot coordination during gait before and after total knee arthroplasty (TKA) with controls (CTRL).

Twenty-seven patients (male=15/female=12; age=63.2±6.9 years) were evaluated one month prior to and twelve months after surgery, and compared to 27 controls (male=14/female=13; age=62.2±4.3). The participants were outfitted with a full-body marker set. Gait speed (normalized by leg length) was calculated. The time series of the thigh, shank, and foot orientation in relation to the laboratory coordinate system were extracted. The coordination between the thigh-shank and shank-foot in the sagittal plane were calculated using a vector coding technique. The coupling angles were categorized into four coordination patterns. The stance phase was divided into thirds: early, mid, and late stance. The frequency of each pattern and gait speed were compared using a one-way ANOVA with a post-hoc Bonferroni correction.

Walking speed and shank-foot coordination showed no differences between the groups. The thigh-shank showed differences. The pre-TKA group showed a more in-phase pattern compared to the CTRL group during early-stance. During mid-stance, the pre- and post-TKA presented a more in-phase pattern compared to the CTRL group. Regarding shank-foot coordination, the groups presented an in-phase and shank pattern, with more shank phase during mid-stance and more in-phase during late-stance.

The pre-TKA group showed greater differences than the post-TKA compared to the controls. The more in-phase pattern in the pre- and post-TKA groups could relate to a reduced capacity for the thigh that leads the movement. During mid-stance in normal gait, the knee is extending, where the thigh and shank movements are in opposite directions. The in-phase results in the TKA groups indicate knee stiffness during the stance phase, which may relate to a muscular deficit or a gait strategy to reduce joint stress.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 26 - 26
11 Apr 2023
Kowalski E Pelegrinelli A Ryan N Dervin G Lamontagne M
Full Access

This study examined pre-operative measures to predict post-operative biomechanical outcomes in total knee arthroplasty (TKA) patients.

Twenty-eight patients (female=12/male=16, age=63.6±6.9, BMI=29.9±7.4 kg/m2) with knee osteoarthritis scheduled to undergo TKA were included. All surgeries were performed by the same surgeon (GD) with a subvastus approach. Patients visited the gait lab within one-month prior to surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), maximum knee flexion and extension strength evaluation, and a walking task. Variables of interest included the five KOOS sub-scores, TUG time, maximum knee flexion and extension strength normalized to body weight, walking speed, and peak knee biomechanics variables (flexion angle, abduction moment, power absorption). A Pearson's correlation was used to identify significantly correlated variables which were then inputted into a multiple regression.

No assumption violations for the multiple regression existed for any variables. Pre-operative knee flexion and extension strength, TUG time, and age were used in the multiple regression. The multiple regression model statistically significantly predicted peak knee abduction moment, post-operative walking speed, and post-operative knee flexion strength. All four variables added statistically significantly to the prediction p<.05.

Pre-operative KOOS values did not correlate with any biomechanical indicators of post-operative success. Age, pre-operative knee flexion and extension strength, and TUG times predicted peak knee abduction moment, which is associated with medial knee joint loading. These findings stress the importance of pre-surgery condition, as stronger individuals achieved better post-operative biomechanical outcomes. Additionally, younger patients had better outcomes, suggesting that surgeons should not delay surgery in younger patients. This delay in surgery may prevent patients from achieving optimal outcomes. Future studies should utilize a hierarchical multiple regression to identify which variables are most predictive.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 17 - 17
1 Dec 2022
Kowalski E Dervin G Lamontagne M
Full Access

One in five patients remain unsatisfied due to ongoing pain and impaired mobility following total knee arthroplasty (TKA). It is important if surgeons can pre-operatively identify which patients may be at risk for poor outcomes after TKA. The purpose of this study was to determine if there is an association between pre-operative measures and post-operative outcomes in patients who underwent TKA.

This study included 28 patients (female = 12 / male = 16, age = 63.6 ± 6.9, BMI = 29.9 ± 7.4 kg/m2) with knee osteoarthritis who were scheduled to undergo TKA. All surgeries were performed by the same surgeon (GD), and a subvastus approach was performed for all patients. Patients visited the gait lab within one-month of surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), and walking task. Variables of interest included the five KOOS sub-scores (symptoms, pain, activities of daily living, sport & recreation, and quality of life), completion time for the TUG, walking speed, and peak knee biomechanics variables (flexion angle, abduction moment, power absorption). A Pearson's product-moment correlation was run to assess the relationship between pre-operative measures and post-operative outcomes in the TKA patients.

Preliminary analyses showed the relationship to be linear with all variables normally distributed, as assessed by Shapiro-Wilk's test (p > .05), and there were no outliers. There were no statistically significant correlations between any of the pre-operative KOOS sub-scores and any of the post-operative biomechanical outcomes. Pre-operative TUG time had a statistically significant, moderate positive correlation with post-operative peak knee abduction moments [r(14) = .597, p < .001] and peak knee power absorption [r(14) = .498, p = .007], with pre-operative TUG time explaining 36% of the variability in peak knee abduction moment and 25% of the variability in peak knee power absorption. Pre-operative walking speed had a statistically significant, moderate negative correlation with post-operative peak knee abduction moments [r(14) = -.558, p = .002] and peak knee power absorption [r(14) = -.548, p = .003], with pre-operative walking speed explaining 31% of the variability in peak knee abduction moment and 30% of the variability in peak knee power absorption.

Patient reported outcome measures (PROMs), such as the KOOS, do indicate the TKA is generally successful at relieving pain and show an overall improvement. However, their pre-operative values do not correlate with any biomechanical indicators of post-operative success, such as peak knee abduction moment and knee power. Shorter pre-operative TUG times and faster pre-operative walking speeds were correlated with improved post-operative biomechanical outcomes. These are simple tasks surgeons can implement into their clinics to evaluate their patients. Future research should expand these findings to a larger sample size and to determine if other factors, such as surgical approach or implant design, improves patient outcomes.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 90 - 90
1 Nov 2021
Kowalski E Catelli D Lamontagne M Dervin G
Full Access

Introduction and Objective

Gait variability is the amplitude of the fluctuations in the time series with respect to the mean of kinematic (e.g., joint angles) or kinetic (e.g., joint moments) measurements. Although gait variability increases with normal ageing or pathological mechanisms, such as knee osteoarthritis (OA). The purpose was to determine if a patient who underwent a total knee arthroplasty (TKA) can reduce gait variability.

Materials and Methods

Twenty-five patients awaiting TKA were randomly assigned to receive either medial pivot (MP, m=7/f=6, age=62.4±6.2 years) or posterior stabilized (PS, m=7/f=5, age=63.7±8.9 years) implants, and were compared to 13 controls (CTRL, m=7/f=6, age=63.9±4.3 years). All patients completed a gait analysis within one month prior and 12 months following surgery, CTRLs completed the protocol once. A waveform F-Test Method (WFM) was used to compare the variance in knee biomechanics variables at each interval of the gait cycle.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 25 - 25
1 Aug 2020
Salimian A Howatt J Dervin G Kim P
Full Access

The Oxford mobile bearing knee prosthesis (Zimmer Biomet Inc, Warsaw, Ind) is considered a good treatment option for isolated medial compartment knee arthrosis. From February 2001 until August 2016, 1719 primary Oxford medial unicompartmental knee replacement procedures were completed at our center by a group of seven surgeons. We undertook this study to examine the long-term survivorship of the Oxford unicompartmental knee replacement looking at survivorship and reasons for failure.

A retrospective consecutive case series review was completed, and all revisions and re-operations were identified. Conversion to total knee replacement (TKA) was considered a failure. Kaplan-Meier survival analysis was used to calculate the 15-year survivorship of the group overall. We specifically looked at age, gender, BMI and surgeon caseload in addition to the reasons for failure. A statistical analysis was performed and differences in survivorship were compared for the variables listed. A logistic cox regression was performed to explore predictors of revision.

Overall 15-year survivorship was 89.9%. Female survivorship of 88.1% was statistically worse than the male group at 91.8% (p=0.018). Younger patients (75yrs of age (p= 0.036). There was a large range in surgical case load by individual surgeons (range 17–570 knees). There were no statistically significant differences in age, BMI, or gender when comparing the individual surgeon groups. There was a large range in 15-year survivorship between individual surgeons (range 78.3% – 95%). Overall the most common reason for revision was due to wear of the unreplaced portion of the knee (lateral and/or patella-femoral joint) followed by aseptic loosening, polyethylene dislocation, infection or persistent pain.

The 15-year survivorship results of the Oxford medial unicompartmental knee replacement at our center compares favourably to other published series and large registry data series. We found a reduction in survivorship in female patients and younger patients (< 5 5yrs). There were also significant differences in survivorship based on the individual surgeon. A more selective patient approach yielded the best long-term survivorship and equivalent to that of total knee replacement. We therefore suggest using a more selective approach when choosing patients for a medial unicompartmental knee replacement with the Oxford mobile bearing prosthesis in order to enhance long-term survivorship.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 12 - 12
1 Jul 2020
Dervin G Cooke TDV
Full Access

Integrated Regional Orthopaedic (MSK) Assessment clinics (ROAC) are now mandated in many provinces for the assessment and triage of patients referred for total joint arthroplasty (TJA). Their introduction underscores the lack of means for Primary Care Physicians (PCP) to appropriately refer patients for surgical consideration. Thus, problems arise when patients who are clear candidates for surgery are subject to a significant extra step in the care pathway by attending a ROAC while those who have insufficient problems are also seen, contributing to costs and crowding the access portal. We postulated that a patient reported outcome measure, decision aid combined with a validated grading of a weight bearing knee X-ray would provide an inexpensive yet effective tool to significantly improve the referral process for Knee OA (compared with the current mechanism).

To date we have enrolled two hundred and forty-five consenting patients to the study, all referred by their PCP to the ROAC with a diagnosis of symptomatic Knee Osteoarthritis. All patients were evaluated as per the current ROAC protocol which included a medical history, physical examination and an X-ray (standing AP, lateral and patella-femoral skyline). Prior to the visit, subjects were sent a copy of a patient decision aid, Oxford Knee Score (OKS) and requested to answer whether their current clinical status described as Patient Acceptable Symptom State (PASS2) was acceptable. All radiographs were analyzed and scored for OA severity using the validated grading from 0 – 13.

Of the 245 cases, 200 completed OKS and PASS2 uestionnaires and had standing X-rays for evaluation (only 120 completed the decision aid and these were left out of this report). Of the 200 included cases, 104 were referred from the ROAC to see a surgeon. In analysis, we found that a self-reported PASS 2 answer NO and an AP X-ray graded at 6 or above predicted over 75% of those patients that were referred. This represents a 3.4 greater likelihood of referral using this simple analysis. The OKS did not modify this prediction.

Thus, use of a validated grading of a standing AP X-ray along with a response, ‘readiness for surgery’ indicated 75% of patients appropriate for surgical consideration. Patients with less severe gradings are likely being unnecessarily referred to ROAC leading to overuse of scarce resources, crowding the access and adding to costs, others, who score higher, are being needlessly delayed. The ability to discreetly screen for the best possible candidates should be a continued focus of ROAC and will lead to improved use of expensive resources, overall patient care and satisfaction and the provision of tools to the PCP for appropriate referral.


Young, active patients with end-stage medial osteoarthritis (OA) secondary to anterior cruciate ligament (ACL) deficiency present a treatment challenge for surgeons. Current surgical treatment options include high tibial osteotomy (HTO) with or without ACL reconstruction, unicompartmental knee arthroplasty (UKA) with ACL reconstruction, and total knee arthroplasty (TKA). A recent systematic review reported a much higher rate of complications in HTO combined with ACL reconstruction than with UKA-ACL (21.1% vs 2.8%), while survivorship between the two procedures was similar. UKA offers several advantages over TKA, namely faster recovery, lower blood loss, lower rate of postoperative complications, better range of motion, and better knee kinematics. However, UKA has classically been contraindicated in the presence of ACL deficiency due to reported concerns over increased incidence aseptic loosening tibia. However, as a majority of patients presenting with this pathology are young and active, concerns about implant longevity with TKRA and loss of bone stock have arisen.

As a result, several authors have described combining ACL reconstruction with medial UKA to decrease the tibiofemoral translation-related stress on the tibial component, thereby decreasing aseptic loosening-related failures. The purpose of this study was to compare the functional outcomes and survivorship of combined medial UKA and ACL reconstruction (UKA-ACL) with those of a matched TKA cohort. We hypothesized that UKA-ACL patients would have better functional outcomes than TKA patients while maintaining similar survivorship.

Material and Methods

We conducted a case-control study establishing UKA-ACL as the study group and TKA as the control group by a single senior surgeon between October 2005 and January 2015. We excluded patients who were over the age of 55 at the time of surgery and those who had less than two-year follow-up. A total of 21 patients (23 knees) were ultimately included in each group. Propensity matching was for age-, sex-, and body mass index (BMI)-matched control group of TKA cases.

Surgical technique


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 59 - 59
1 Apr 2019
Lamontagne M Kowalski E Galmiche R Dervin G
Full Access

Many patients who undergo a total knee arthroplasty (TKA) wish to return to a more active lifestyle. The implant must be able to restore adequate muscle strength and function. However, this may not be a reality for some patients as quadriceps and hamstrings muscle activity may remain impaired following surgery.

The purpose of this study was to compare muscle activity between patients implanted with a medial pivot (MP) or posterior stabilized (PS) implant and controls (CTRL) during ramp walking tasks.

Fifteen patients were assigned to either a MP (n=9) or PS (n=6) TKA operated by the same surgeon. Nine months following surgery, the 15 patients along with nine CTRL patients completed motion and EMG analysis during level, ramp ascent & descent walking tasks.

Wireless EMG electrodes were placed on six muscles: vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), semimembranosus (SM) muscles, gastrocnemius medial head (GM), and gastrocnemius lateral head (GL). Participants completed three trials of each condition.

EMG data were processed for an entire gait cycle of the operated limb in the TKA groups, and for the dominant limb in the CTRL group. The maximum muscle activity achieved with each muscle during the level trial was used to normalize the ramp trials. The onset and offset of each muscle was determined using the approximated generalized likelihood ratio.

Peak muscle activity (PeakLE), total muscle activity (iEMG), and muscle onsets/offsets were determined for each muscle for the ramp ascent and descent trials. Non-parametric Kruskal Wallace tests were used to test for statistical significance between groups with α=0.05.

During the ramp up task, both MP and PS groups had significantly greater PeakLE and iEMG for the hamstring muscles compared to the CTRL, whereas the PS group had significantly greater PeakLE compared with the MP group for the SM muscle.

During the ramp down task, both MP and PS groups had significantly greater PeakLE and iEMG for the SM and GL muscles compared to the CTRL. The PS group also had significantly greater iEMG for the BF and VM muscles compared to the CTRL. The MP group had a significantly earlier offset for the SM muscle compared to the CTRL.

Stability in a cruciate removing TKA is partially controlled by the prosthetic design. During the ramp up task, the TKA groups compensated the tibial anterior translation by activating their hamstrings more and for a longer duration. The MP group required less hamstrings activation than the PS group.

During the ramp down task, TKA patients stiffened their knee in order to stabilize the joint. The quadriceps, hamstrings and GL muscle were activated more and for a longer duration than the CTRL group to protect the tibial posterior translation. The PS group required greater BF and VM iEMG than the MP group.

Even if surgery reduced pain, differences in muscle activity exist between TKA patients and healthy controls. The prosthetic design provides some stability to the knee, and the MP implant required less muscle activation than the PS implant to stabilize the knee joint.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 99 - 99
1 Feb 2017
Lamontagne M Kowalski E Dervin G
Full Access

Introduction

Patients undergoing a total knee arthroplasty (TKA) are now living longer and partaking in more active lifestyles. They expect a high level of post-operative function and long term durability of their implant.

Using electromyography (EMG) analysis helps further explain biomechanical findings by giving insight as to what is occurring at the level of the muscles. Normal biomechanics are not restored post-TKA as patients have reduced knee flexion and weakened quadriceps muscles compared to their healthy peers.

Purpose

The purpose of this study was to compare muscle activation in TKA patients who received a medial pivot (MP) or posterior stabilized (PS) implant to those of healthy controls (CTRL) during a stair ascent task.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 90 - 90
1 Nov 2016
Gauthier-Kwan O Dervin G Dobransky J
Full Access

An outpatient TKA program was developed by integrating advances in analgesia, rehabilitation, and minimally invasive surgical techniques with the objective of improving value in elective total knee arthroplasty (TKA) while maintaining quality standards. Previous studies have established the safety of outpatient TKA in selected populations, but the literature is devoid of outcome measures in these patients. Our goal was to investigate the quality of recovery, patient satisfaction, and safety profile in the first 90 days undergoing outpatient TKA.

One hundred TKAs in 93 consecutive patients with end-stage arthritis of the knee candidate for primary TKA were enrolled in this prospective matched cohort study. Patients that underwent inpatient TKA (47 TKAs) were compared with patients that underwent planned outpatient TKA (53 TKAs). The following 28 day post-operative scores were recorded: quality of recovery (QoR-18) and pain scores by Numerical Rating Scale (NRS-11). Satisfaction with pain control (0 to 10) and quantity of opioid use was collected. Secondary outcome measures of 90-day complications, readmissions, and emergency department (ED) visits were recorded.

Ninety-six percent of patients planned for outpatient TKA met our defined multidisciplinary criteria for same-day discharge. QoR-18 at post-operative day one was statistically higher in the outpatient TKA group. Otherwise, outcome measures were not statistically different between the 2 groups. Two patients required overnight admission: 1 for extended motor-block and 1 for vasovagal syncope. There were 7 ED visits in the in the outpatient group and 4 in the inpatient group. One outpatient was admitted for irrigation and debridement with liner exchange for an acute infection 2 weeks post-operatively. One inpatient required manipulation under anesthesia at six weeks post-operatively.

Outpatient TKA in selected patients produced a post-operative quality of recovery and patient satisfaction similar to that of inpatient TKA. Our results support that outpatient TKA is a safe alternative that should be considered due to its potential cost-savings and comparable recovery.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 3 - 3
1 Nov 2016
Lamontagne M Kowalski E Dervin G
Full Access

The purpose of this study was to compare lower limb joint mechanics in patients who underwent a total knee arthroplasty (TKA) with either a posterior stabilised (PS) or with a medial pivot (MP) implant to healthy controls (CTRL) during stair ascent and descent tasks.

Six PS (age: 67.2±1.5 years, BMI: 31.0±3.2 kg/m2) and 11 MP (age: 62.3±6.0 years, BMI: 29.7±3.9 kg/m2) TKA patients matched to 10 healthy CTRL participants (age: 65.6±5.5 years, BMI: 27.2±5.0 kg/m2) were included in the study. TKA patients went through 3D motion analysis after unilateral TKA with either a MP (11.7±3.4 months post-surgery) or PS (10.1±3.4 months post-surgery) implant performed using either a subvastus or medial parapatellar approach. Kinematic and kinetic data was collected using a 10-camera Vicon and two portable Kistler force plates placed on the first and second stair of a three-step staircase. Nonparametric Kruskal Wallace ANOVA tests were used and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred.

When comparing both stair tasks, stair ascent showed a larger number of significant differences in kinematic and kinetic variables than stair descent. Peak knee extension was significantly (p < 0.05) greater in both TKA groups compared to the CTRL during stair descent, whereas only the PS group had significantly (p = 0.02) greater knee extension angle than the CTRL during stair ascent. The PS group had a significantly (p = 0.01) lower peak knee extension moment than the CTRL group during both tasks and compared to the MP group during stairs ascent. During stair ascent, the MP group had significantly (p = 0.02) larger peak hip extension moments than both PS and CTRL group.

Greater knee extension angles in TKA groups at foot strike during stair tasks support the notion that TKA groups exhibit stiff knee during stance to reduce or avoid shear displacement on the operated knee. This could also result from many years of muscle adaptation waiting to receive a knee replacement. Reduced peak knee extension moment in the PS group during stairs tasks showed a quadriceps deficiency that could increase the risk of revision or of other joint replacement on the contralateral side or ipsilateral hip. MP group reproduced similar joint loading patterns as the CTRLs which may reduce their risk of revision. In conclusion, TKA patients continue to exhibit discrepancies from healthy knee mechanics during stair ascent and descent. Further research examining muscle function especially during stair ascent is warranted.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 21 - 21
1 Nov 2016
Chen B Garland K Roffey D Poitras S Lapner P Dervin G Phan P Wai E Kingwell S Beaulé P
Full Access

The Spine Adverse Events Severity System (SAVES) and Orthopaedic Surgical Adverse Events Severity System (OrthoSAVES) are standardised assessment tools designed to record adverse events (AEs) in orthopaedic patients. The primary objective was to compare AEs recorded prospectively by orthopaedic surgeons compared to trained independent clinical reviewers. The secondary objective was to compare AEs following spine, hip, knee, and shoulder orthopaedic procedures.

Over a 10-week period, three orthopaedic spine surgeons recorded AEs following all elective procedures to the point of patient discharge. Three orthopaedic surgeons (hip, knee, and shoulder) also recorded AEs for their elective procedures. Two independent reviewers used SAVES and OrthoSAVES to record AEs after reviewing clinical notes by surgeons and other healthcare professionals (e.g. nurses, physiotherapists). At discharge, AEs recorded by the surgeons and independent reviewers were recorded in a database.

AE data for 164 patients were collected (48 spine, 52 hip, 33 knee, and 31 shoulder). Overall, 98 AEs were captured by the independent reviewers, compared to 14 captured by the surgeons. Independent reviewers recorded significantly more AEs than surgeons overall, as well as for each individual group (i.e. spine, hip, knee, shoulder) (p2), but surgeons failed to record minor events that were captured by the independent reviewers (e.g. urinary retention and cutaneous injuries; AEs Grade 0.05). AEs were reported in 21 (43.8%), 19 (36.5%), 12 (36.4%), and five (16.1%) spine, hip, knee, and shoulder patients, respectively. Nearly all reported AEs required only simple or minor treatment (e.g. antibiotic, foley catheter) and had no effect on outcome. Two patients experienced AEs that required invasive or complex treatment (e.g. surgery, monitored bed) that had a temporary effect on outcome.

Similar complication rates were reported in spine, hip, knee, and shoulder patients. Independent reviewers reported more AEs compared to surgeons. These findings suggest that independent reviewers are more effective at capturing AEs following orthopaedic surgery, and thus, could be recruited in order to capture more AEs, enhance patient safety and care, and maximise different complication diagnoses in alignment with proposed diagnosis-based funding models.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 2 - 2
1 Nov 2016
Lamontagne M Kowalski E Dervin G
Full Access

The purpose of this study was to compare lower limb muscle activity in patients who underwent a total knee arthroplasty (TKA) with a medial pivot (MP) implant to healthy controls (CTRL) during a stair ascent task.

Seven MP (age: 61.4±6.5 years, BMI: 30.0±4.7 kg/m2, 12.4±3.8 months post-surgery) patients who underwent a TKA performed using either a subvastus or medial parapatellar approach were age- and BMI-matched to seven healthy CTRL participants (age: 62.4±4.2 years, BMI: 26.3±2.7 kg/m2) for comparison in this study. Participants underwent electromyography (EMG) analysis while completing a three-step stairs ascent task. Portable wireless surface EMG probes were placed on the vastus lateralis (VL), rectus femoris (RF), vastus medialis (VM), biceps femoris (BF) and semimembranous (SM) muscles of both lower limbs. Peak linear envelope (peakLE) and total muscle activity (iEMG) were extrapolated and normalised to a maximal voluntary contraction. Nonparametric Kruskal Wallace ANOVA tests were used and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred.

The operated limb had significantly lower iEMG in the VAL, RF and BF muscles, and significantly lower peakLE in the SM muscle compared to the non-operated limb. The operated-limb of the MP group had significantly lower iEMG in the VAL and BF muscles, and significantly lower peakLE in the VAL, RF and SM muscles compared to the CTRL group. The non-operated limb in the MP group had significantly larger peakLE and iEMG in the RF muscle compared to the CTRL group.

Differences in muscle activity between the operated and non-operated limbs in TKA patients with a MP implant demonstrates a compensatory strategy to reduce loading on the operated limb by relying on the non-operated limb. This same strategy has been reported in other studies investigating other functional tasks. This reliance on the non-operated limb resulted by having greater peakLE and iEMG in the RF muscle compared to the healthy CTRLs. These differences between limbs could also result from many years of muscle adaptation waiting to receive a knee replacement. In conclusion, TKA patients exhibit discrepancies in muscle activity compared to healthy knees and differences between operated and non-operated limbs. Post-surgery rehabilitation should rely on unilateral strength exercises of the quadriceps and hamstrings muscles to reduce discrepancies to allow for a more balanced muscle activity between limbs.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 97 - 97
1 Sep 2012
Dervin G Thurston PR
Full Access

Purpose

Patients with anterior cruciate ligament (ACL) deficiency and symptomatic medial compartment osteoarthritis (OA) present a challenge in management. These are often younger than typical primary OA patients and aspire to remain athletically active beyond simple ADLs. Combined ACL reconstruction and valgus tibial osteotomy (ACLHTO) is a well documented surgical option for patients deemed wither too young or too active for total knee arthroplasty. Unicompartmental knee arthroplasty (UKA) is an established surgical treatment for symptomatic medial osteoarthritis of the knee refractory to conservative management. A commonly cited contraindications is symptomatic ACL deficiency because of previous reports detailing premature failure through loosening of the tibial component. Improved results and endoscopic ACL reconstructive procedures have led to an enticing concept of combining ACL reconstruction with medial unicompartmental knee arthroplasty (ACLUKR) for those ACL-deficient medial osteoarthritic (OA) knees. We sought to compare the outcomes in 2 cohorts of patients who underwent either ACLHTO or ACLUKR for this clinical problem.

Method

Patients presenting with symptomatic bone on bone medial compartment OA and concomitant ACL deficiency (clinical or asymptomatic) were evaluated for surgery after exhausting non operative management. Patients who were under 40 or had plans to return to high impact loading sports and/or who had more moderate OA were offered combined ACL – medial opening wedge tibia osteotomy as a surgical procedure of choice. Patients were considered for combined ACL Oxford replacement if they were primarily seeking pain relief and were not engaged or aspiring to return to high impact or pivoting sports. All cases but one were concurrent ACL with either HTO or UKR with autogenous hamstring grafts used in all but 2 cases


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 25 - 25
1 Sep 2012
Prud'homme-Foster M Louati H Parai M Dervin G
Full Access

Purpose

Unicompartmental knee replacement (UKR) is an established, bone preserving surgical treatment option for medial compartment osteoarthritis (OA). Early revision rates appear consistently higher than those of total knee replacement (TKR) in many case series and consistently in national registry data. Failure with progression of OA in the lateral compartment has been attributed, in part, to surgical technical errors. In this study we used navigation assisted surgery to investigate the effects of improper sizing of the mobile bearing and malrotation of the tibial component on alignment and lateral compartment loading.

Method

A total of eight fresh frozen cadaveric lower limbs were used in the study. After thawing overnight, a Brainlab navigation system with an Oxford (Biomet, Inc) medial UKR module was used to capture the native knee anatomy and alignment using a digitizing probe. Following registration, the case was performed with navigation verified neutral cuts and an ideal insert size was selected to serve as a baseline. The bearing thickness was subsequently increased by 2 mm increments to simulate progressive medial joint overstuffing. Excessive tibial internal rotation of 12 was also simulated at each of the intervals. Knee alignment in varus or valgus was recorded in real time for each surgical scenario with the knee in full extension and at 20 of flexion. Lateral compartment peak pressure was measured using a Tekscan pressure map.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 263 - 263
1 Jul 2011
Dervin G Evans H Madden S Thurston PR
Full Access

Purpose: Unicompartmental replacement for medial compartment arthrosis of the knee has become popular with eligible patients because of the shortened recovery time, decreased tissue damage and easier future revision. Contemporary multimodal anesthesia has added the potential to safely perform this as outpatient surgery reducing inpatient bed burden. We describe our initial pilot experience with this approach.

Method: The first 25 patients who fulfilled the criteria developed underwent same day surgery for unicompart-mental arthroplasty for medial (19) or lateral (3) compartment replacement with either the Oxford knee (20) or the Uniglide (2). All patients were treated with an indwelling femoral nerve catheter supplied by Ropivacaine through a constant release pump (Stryker) which was discontinued at 48 hours. Home care support was made available in first 72 hours by way of RN and physiotherapy visits and mandatory use of walker or crutches for the first 48 hours.

Results: Patients in this cohort were universally very satisfied with the model of postop care as described and particularly pleased to avoid a hospital stay. Eighty percent of those who were offered this model chose it. The use of narcotic oral medication was consistently about 50% less than that observed to similar inpatients treated without catheter, and eight patients had complete opioid sparing experience. There were no complications related to the catheter, in particular serious falls or longer term neurologic sequelae. The clinical results were very good and equal to those who were in patients.

Conclusion: Outpatient unicompartmental replacement can be performed safely recognizing the decreased surgical trauma and pain stimuli associated with UKR and a relatively younger and healthier cohort screened for this alternative. These patients are amongst the most satisfied with their perioperative course and all would do the same again if given the chance. Other models of analgesia could be considered, though the catheter does seem to have a large opioid sparing effect that likely contributed to patient well being and satisfaction.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 2 - 2
1 Mar 2010
Dare EV Poitras P Dervin G Giulivi A Griffith M Hincke MT
Full Access

Purpose: The objective of this project is to evaluate the human fibrin glue, CryoSeal®, as a scaffold for articular cartilage tissue engineering. An autologous system would eliminate risks associated with biocompatibility and virus transmission.

Method: Human articular chondrocytes were isolated from articular cartilage harvested from consenting patients undergoing total knee arthroplasty. The cells were encapsulated into CryoSeal® fibrin glue – which is derived from a single patient’s plasma using the Cryo-Seal® Fibrin Sealant System (Thermogenesis Corp.) – and cross-linked with genipin, which is a natural cross-linking agent with anti-inflammatory activity. The resulting gels were cultured in vitro for up to 7 weeks under either normal (21%) or low oxygen (5%) conditions and were evaluated for mechanical properties, extracellular matrix (ECM) production, viability, and biodegradation. Fibrin glue components were isolated from either fresh or frozen plasma.

Results: The dynamic compression modulus of the genipin cross-linked fresh plasma (FSP) CryoSeal® gels increased by ~4.4-fold over 5 weeks in culture. The glycosaminoglycan (GAG) content of the FSP gels increased by 4.7-fold over 5 weeks in low oxygen (LO) culture, which was 1.7-fold greater than in normal oxygen (NO) culture. The total collagen content of the FSP cultures increased by 6.0-fold over 5 weeks in LO culture, which was 2.2-fold greater than in NO culture. These changes in ECM were confirmed by histology (Alcian Blue) and immunostaining (to detect collagen II, collagen I, aggrecan, Sox9) of gel cryosections. After 5 weeks in LO culture the FSP CryoSeal®-encapsulated chondrocytes expressed a 6.4 ± 1.1 fold increase in collagen II gene expression, which was 5.8 ± 1.0 fold greater than in NO cultures. In addition, chondrocyte viability within the FSP and frozen plasma (FZP) CryoSeal® gels was ~90% at both 24 hours and 2 weeks after gelation. When fibrin hydrogels were implanted subcutaneously into rats it was found that inflammation was inhibited with increasing genipin and when the material origin was species-specific.

Conclusion: The CryoSeal® fibrin gel system demonstrates promise for autologous human articular cartilage tissue engineering. An in vivo orthopaedic implantation model must be developed for further testing.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 2 - 3
1 Mar 2010
Ahmed TAE Halpenny M Atkins H Giulivi A Dervin G Griffith M Hincke M
Full Access

Purpose: Articular cartilage is a physiologically hypoxic tissue with a gradient of oxygen tension ranging from about 10% oxygen at the cartilage surface to less than 1% in the deepest layers. The overall goal of the study was to determine whether an injectable allogeneic/autologous fibrin scaffolds in combination with mesenchymal stem cells (MSCs) is suitable for articular cartilage tissue engineering, and to determine the effect of hypoxic culture conditions on the stability of cell-fibrin scaffolds. The secondary goal was to enhance the accumulation of extracellular matrix (ECM) inside the fibrin scaffold under these conditions.

Method: Chondroprogenitor clonal cell line RCJ3.1C5.18 (C5.18) and human mesenchymal stem cells (hMSCs) were encapsulated in fibrin hydrogel and fibrin glue scaffolds. The stabilization of fibrin scaffolds and development of ECM components were evaluated using zymography, SDS-polyacrylamide electrophoresis (SDS-PAGE), immunochemistry, spectrophotometry, RT-PCR including real time and histology (Ahmed TA., et al. Tissue Engineering2007;13(7): 1469–77).

Results: After encapsulation of C5.18 and hMSCs, fibrin gels quickly degraded under normoxic conditions (21 % oxygen) due to upregulation of plasminogen and matrix metalloproteinases (MMPs) genes especially MMP-2, -3, and -9. Protease inhibitors such as aprotinin and galardin (GM6001), in combination or separately, prevented the fibrin-C5.18 hydrogels breakdown for up to 5 weeks. Only a combination of aprotinin and galardin resulted in accumulation of ECM components such as collagen II and aggrecan. In contrast, fibrin-hMSCs hydrogels were found to be stable under hypoxic conditions (5% O2) for up to 4 weeks in the absence of inhibitors, suggesting that hypoxic conditions may downregulate the expression of the enzymes responsible for fibrin-hydrogel breakdown.

Conclusion: These results suggest that in C5.18 and MSCs cell lines, expression of matrix metalloproteinases (MMPs) and plasmin is upregulated under normoxic conditions and is responsible for fibrin-hydrogel breakdown. Moreover, inhibition of both proteases is required to enhance the accumulation of ECM. However, fibrin hydrogel scaffolds were stabilized under low oxygen tension, which is more physiological than normoxia and therefore these constructs may be stable after implantation in the absence of protease inhibitors.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 56 - 56
1 Mar 2008
Fallatah S Dervin G Brunet J Conway A Hrushowy H
Full Access

We reviewed forty-three patients who had humeral head replacement for proximal humeral fractures between 1992–2000, with a minimum of two years of follow-up. The patients were evaluated for range of motion, post-operative pain, and the overall activities using the American Shoulder and Elbow Surgeons Evaluation form (ASESE) and the Western Ontario Rotator Cuff Index (WORC). Patients with delayed surgery had more pain than those with primary hemiarthroplasty, all of which were treated with the Global type prosthesis. Postoperative pain was significantly associated with the presence of intra-operative cuff tear.

The purpose of this study was to evaluate the functional outcome after hemiarthroplasty for proximal humeral fractures and whether the prosthesis type, intra-operative technique, or the presence of previous surgery would affect the outcome.

The Medical records and radiographs of patients who had hemiarthroplasty for proximal humeral fractures between 1992–2000 were reviewed. Forty-three patients were identified, thirty-seven with acute fractures and six with fracture related complications. One surgeon performed fifteen cases (35%), while the rest divided among eleven others. The patients were evaluated for pain, range of motion, strength, stability, and function using the American Shoulder and Elbow Surgeons Evaluation form (ASESE) and Western Ontario Rotator Cuff Index. The radiographs were reviewed by the senior authors.

The mean age of the patients at presentation was sixty-nine year (range forty-six to ninety-five year). The mean duration of follow-up was 4.6 years. The mean active forward elevation was ninety-six, active external rotation twenty-two, and the mean active internal rotation was eight. Fifteen percent of the patients reported severe pain and twenty-five percent were unable to sleep on the affected side. The patients with previous surgeries and those with intra-operative cuff tear were found to have more post-operative pain (p=0.027 and 0.022 respectively). The Global type prosthesis was used in all the cases of secondary hemiarthroplasty (p=0.031) and all the Neer prostheses were cemented (0.001).

We concluded that integrity of rotator cuff and primary surgery were more inclined to better results. There does remain significant stiffness and pain in most patients however.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 112 - 112
1 Mar 2008
Brown C Deheshi B Dervin G
Full Access

Femoral neck fractures in the elderly has a devastating impact on health and resources. Past trends suggest pinning un-displaced fractures in the more active elderly patients and resorting to arthroplasty in those less active. In our study the failure rate for un-displaced fractures (18.4%) was greater than that quoted in the literature and greater than the failure rate of fractures treated with arthroplasty (7.4%). Failures consisted of AVN (5), nonunion/malunion (1) and loss of fixation (1). This data suggests that arthroplasty would decrease the failure rate in our study group.

To evaluate the outcome of ORIF for un-displaced femoral neck fractures in the elderly at a tertiary care teaching hospital.

ORIF of femoral neck fractures in the elderly at our institution resulted in higher failure rates than quoted in the literature. A large multi-center randomized controlled trial is warranted to establish clear guidelines in the management of these injuries.

In our study the failure rate for undisplaced fractures was greater than fractures treated with arthroplasty. The clinical relevance of this data suggests that not all un-displaced fractures go on to uneventful union.

Of the forty-five patients that met the inclusion criteria for un-displaced femoral neck fracture, seven of which were originally treated at our institution failed, resulting in 18.4% failure rate. In comparison, our complication rates for displaced femoral neck fractures treated with arthroplasty results in a 7.4% failure rate. Failures consisted of AVN (5), nonunion/malunion (1) and loss of fixation (1).

Retrospective study. Patients sixty-five to eighty years of age with un-displaced femoral neck fractures repaired by cannulated screw fixation from 1995 to 2001. X-ray confirmation was done when fracture was not described in the chart. Failure of pinning was defined as requiring re-operation or arthroplasty.

Recent studies argue in favor of arthroplasty for most displaced femoral neck fractures. Despite the limitations of our study, the failure rate of the un-displaced femoral neck fracture is higher than that quoted in the literature, and suggests that arthroplasty would decrease the failures in our study group.