Vol. 93-B, Issue SUPP_IV | Pages 542 - 542
1 Nov 2011
Dao C Laffosse J Bensafi H Tricoire J Chiron P Puget J
Full Access

Purpose of the study: We report the clinical and radiographic results of a series of revision total hip arthroplasties performed for aseptic loosening using a non-demented modular femoral implant (PP).

Material and methods: From 1991 to 2003, 146 revisions of total hip arthroplasty were performed using the same non-cemented modular femoral implant (PP). At mean nine years follow-up (3.5–17 years), 24 patients had died, 26 had insufficient data for review and 39 were lost to follow-up. The analysis thus included 54 cases. All revisions were performed for aseptic loosening. Mean age at surgery was 60 years. Preoperative bone damage, according to the Sofcot classification, was grade I and II (69%), grade III (26%), grade IV (5.5%). Clinical outcome was assessed with the Harris and Postel-Merle-d’Aubigné scores. The radiological review analysed stem anchoring, lucency and periprosthetic reconstruction.

Results: At mean nine years follow-up, the mean Harris score was 71 points, the mean PMA score 12.8 points. Patient satisfaction was 70%. There were five cases with deep infection (9%), five with dislocation and six intra-operative periprosthetic fractures. Trochanterotomy non-union was noted in 26% of patients. Mean impaction of the femoral stem was 5 mm (range 0–16 mm). There was a statistically significant association between the degree of bone damage and the quality of the bone reconstruction (p=0.012). Mean increase in cortical thickness in zones 1 and 2 (Gruen) was 1.1 mm and 1.6 mm respectively. In Gruen zones 2 and 6, the gain was 6 and 10 mm respectively. There were nine surgical revisions (17%) for deep infection (n=4), recurrent aseptic loosening and fracture of the femoral implant (n=1). The ten-year survival taking aseptic loosening as the endpoint was 90%.0

Discussion and Conclusion: Our work showed the good long-term results obtained with this implant for revision total hip arthroplasty. It allows clinical improvement, periprosthetic bone reconstruction and a low rate of surgical revision.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 292 - 292
1 Jul 2008
BENSAFI H GIORDANO G LAFFOSSE J DAO C PAUMIER F JONES D TRICOIRE J MARTINEL V CHIRON P PUGET J
Full Access

Purpose of the study: Percutaneous compressive plating (PCCP) enables minimally invasive surgery using closed focus technique. We report a prospective consecutive series of 67 fractures (December 2003 – February 2005) followed to bone healing.

Material and methods: Mean patient age was 83 years (range 37–95) with 83% females in a frail population (ASA 3, 4). Two-thirds of the patients had unstable fractures (AO classification) which were reduced on an orthopedic table under fluoroscope. Two minimal incisions were used to insert the material without opening the fracture and without postoperative drainage. Blood loss was noted. Verticalization and weight bearing were encouraged early depending on the patient’s status but were never limited for mechanical reasons. Patients were reviewed at 2, 4 and 6 months.

Results: Anatomic reduction was achieved in 84% of hips, with screw position considered excellent for 45, good for 14, and poor for 6. There were no intraoperative complications. The material was left in place. The hemoglobin level fell 2.2 g on average. Mean operative time was 35 minutes and the duration of radiation exposure 60 seconds. Mean hospital stay was 13 days. General complications were: urinary tract infections (n=10), phlebitis (n=2), talar sores (n=5). Gliding occurred in three cases (4%) with telescopic displacement measuring less than 10 mm in ten cases. There were two varus alignments with no functional impact. There were four deaths within the first three weeks. All fractures healed within three months.

Discussion and conclusion: PCCP has its drawbacks (mechanical, stabilization) as do all osteosynthesis methods used for trochanteric fractures. The technique is reliable and reproducible and is indicated for all trochanteric fractures excepting the subtrochanteric form. PCCP has the advantage of a closed procedure with a minimal incision and limited blood loss for a short operative time. An advantage for this population of elderly frail subjects (ASA 3, 4). PCCP enables immediate treatment with a low rate of material disassembly compared with other techniques.