Total hip replacement (THR) for end-stage osteoarthritis is a commonly performed cost-effective procedure, which provides patients with significant clinical improvement. Estimating the future demand for joint replacement is important to identify the healthcare resources needed. We estimated the number of primary THRs that will need to be performed up to the year 2060.

We used data from The National Joint Registry for England, Wales, Northern Ireland and the Isle of Man on the current volume of primary THR (n=94,936) performed in 2018. We projected future numbers of THR using a static estimated rate from 2018 applied to population growth forecast data from the UK Office for National Statistics up to 2060.

By 2060, primary THR volume would increase from 2018 levels by an estimated 37.7% (n=130,766). For both males and females demand for surgery was also higher for patients aged 70 and over, with older patients having the biggest relative increase in volume over time: 70–79 years (144.6% males, 141.2% females); 80–89 years (212.4% males, 185.6% females); 90 years and older (448.0% males, 298.2% females).

By 2060 demand for THR is estimated to increase by almost 40%. Demand will be greatest in older patients (70 years+), which will have significant implications for the health service that requires forward planning given morbidity and resource use is higher in this population. There is a backlog of current demand with cancellation of elective surgery due to seasonal flu pressures in 2017 and now Covid-19 in 2020. Orthopaedics already has the largest waiting list of any speciality. These issues will negatively impact the health services ability to deliver timely joint replacement to many patients for a number of years and require urgent planning.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 17 - 17
1 Dec 2013
Bolland B Gardner E Roques A Maul C Culliford D Zeineh N O'Hara L
Full Access

This study reports the mid-term results of a large bearing uncemented metal on metal total hip replacement (MOMHTHR) matched series using the Synergy stem and Birmingham modular head in 36 hips (mean follow up 61 months). All patients underwent clinical, metal ion and MRI assessment. Wear analysis was performed on retrieved heads using Redlux non-contact optical profilometry.

Seven patients (19%) have undergone revision surgery. All revisions had two or more of either symptoms, high metal ions or an MRI suggestive of an adverse reaction to metal debris (ARMD). There was no evidence of component malposition or impingement. Frank staining of tissues together with high volume dark brown fluid collections were found in all cases. All stems and cups were well fixed. In 4 cases pubic and ischial lysis (adjacent to the inferior fins) was observed. All 7 cases had radiological, intraoperative and histological evidence of ARMD (Figure 1). The failure cohort had significantly higher whole blood cobalt ion levels and OHS (p = 0.001), but no significant difference in cup size (p = 0.77), gender predominance, stem offset or cup position (p = 0.12). Sleeves had been used in all revision cases

Wear analysis (n = 4) demonstrated increased wear at the trunnion/sleeve interface in a distribution compatible with micromotion (Figure 2). There was normal wear at the articulating surface.

This series further demonstrates unacceptable failure rates in LHMOMTHR in a series where a compatible stem for the BHR modular head was used. Use of a CoCr sleeve within a CoCr head taper appears to contribute to abnormal wear and therefore potential ARMD and subsequent failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 388 - 388
1 Dec 2013
Latham J Cook R Bolland B Wakefield A Culliford D Tilley C
Full Access

Introduction

Metal on metal hip arthroplasty continues to be controversial. Emerging evidence suggests that there are multiple modes of failure, and that the results of revision surgery are influenced by host and implant factors.

Methods

This study compares a single surgeon series of hip resurfacings (Birmingham Hip Resurfacing {BHR}) and large diameter metal on metal total hip replacements (LDMOMTHR). Primary outcome measures included survival rates, failure secondary to histologically identified Adverse Reaction to Metal Debris (ARMD), and patient reported outcome measures (Oxford Hip Score {OHS}) following revision.

Between 1999 and 2005, 458 BHR and 175 LDMOMTHR were performed. At latest review 43 BHR's (9.4%) and 28 LDMOMTHR's (14%) have been revised.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 4 - 4
1 Sep 2012
Bolland B Culliford D Langton D Millington J Arden N Latham J
Full Access

This study reports the mid-term results of a large bearing hybrid metal on metal total hip replacement (MOMHTHR) in 199 hips (185 patients) with mean follow up of 62 months. Clinical, radiological, metal ion and retrieval analysis were performed.

Seventeen patients (8.6%) had undergone revision, and a further fourteen are awaiting surgery (defined in combination as failures). Twenty one (68%) failures were females. All revisions and ten (71%) awaiting revision were symptomatic. Twenty four failures (86%) showed progressive radiological changes.

Fourteen revision cases showed evidence of adverse reactions to metal debris (ARMD). The failure cohort had significantly higher whole blood cobalt ion levels (p=0.001), but no significant difference in cup size (p=0.77), inclination (p=0.38) or cup version (p=0.12) compared to the non revised cohort. Female gender was associated with increased risk of failure (p=0.04). Multifactorial analysis demonstrated isolated raised Co levels in the absence of symptoms or XR changes were not predictive of failure (p=0.675). However the presence of pain (p<0.001) and XR changes (p<0.001) in isolation were significant predictors of failure. Wear analysis (n=5) demonstrated increased wear at the trunnion/head interface (mean out of roundness measurements 34.5 microns (normal range 8–10 microns) with normal wear levels at the articulating surfaces. Macroscopically corrosion was evident at the proximal and distal stem surfaces. Cumulative survival rate, with revision for any reason was 92.4% (95%CI: 87.4–95.4) at 5 years. Including those awaiting surgery, the revision rate would be 15.1% with 89.6% (95% CI: 83.9–93.4). Cumulative survival at 5 years.

This MOMHTHR series has demonstrated unacceptable high failure rates with evidence of high wear at the head/trunnion interface and passive corrosion to the stem surface. Female gender was an independent risk factor of failure. Metal ion levels remain a useful aspect of the investigation work up but in isolation are not predictive of failure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 171 - 171
1 Sep 2012
Mirza S Tilley S Aarvold A Sampson M Culliford D Dunlop D
Full Access

Introduction

Controversy exists as to whether the short external rotator tendons and capsule of the hip should be repaired after posterior approach primary total hip arthroplasty (THA). Recent studies using radiopaque markers have demonstrated that reimplantation of these muscle tendons fail early and may not prevent post operative dislocation.

Methods

Using dynamic ultrasound examination we evaluated the patency of repair in 68 tendon groups (piriformis/conjoint tendon and obturator externus). We demonstrate short and medium term success in the reimplantation of these tendons using the double transosseous drill hole technique of reattaching the tendons and capsule to the greater trochanter. We followed up 21 of our total hip replacements and 13 hip resurfacings and undertook a dynamic ultrasound examination of the external rotators by an experienced musculoskeletal radiologist to assess their integrity at a minimum of 60 days and 100 days and an average of 213 days after the operation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 3 - 3
1 Aug 2012
Bolland B Culliford D Langton D Millington J Arden N Latham J
Full Access

This study reports the mid-term results of a large bearing hybrid metal on metal total hip replacement (MOMHTHR) in 199 hips (185 patients) with mean follow up of 62 months. Clinical, radiological outcome, metal ion levels and retrieval analysis were performed.

Seventeen patients (8.6%) had undergone revision, and a further fourteen are awaiting surgery (defined in combination as failures). Twenty one (68%) failures were females. All revisions and ten (71%) of those awaiting revision were symptomatic. Twenty four failures (86%) showed progressive radiological changes.

Fourteen revision cases showed evidence of adverse reactions to metal debris (ARMD). The failure cohort had significantly higher whole blood cobalt ion levels (p=0.001), but no significant difference in cup size (p=0.77), inclination (p=0.38) or cup version (p=0.12) in comparison to the non revised cohort. Female gender was associated with an increased risk of failure (chi squared p=0.04). Multifactorial analysis demonstrated isolated raised Co levels in the absence of either symptoms or XR changes was not predictive of failure (p=0.675). However both the presence of pain (p<0.001) and XR changes (p<0.001) in isolation were both significant predictors of failure. Wear analysis (n=5) demonstrated increased wear at the trunnion/head interface (mean out of roundness measurements of 34.5 microns +/−13.3 (+/−2SD, normal range 8-10 microns) with normal levels of wear at the articulating surfaces. There was evidence of corrosion at the proximal and distal stem surfaces. The cumulative survival rate, with revision for any reason was 92.4% (95%CI: 87.4-95.4) at 5 years. Including those awaiting surgery, the revision rate would be 15.1% with cumulative survival at 5 years of 89.6% (95% CI: 83.9-93.4).

This MOMHTHR series has demonstrated unacceptable high failure rates with evidence of high wear at the head/trunnion interface and passive corrosion to the stem surface. This raises concern with the use of large heads on conventional 12/14 tapers. Female gender was an independent risk factor of failure. Metal ion levels remain a useful aspect of the investigation work up but in isolation are not predictive of failure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 79 - 79
1 May 2012
Bolland B Culliford D Maskell J Latham J Dunlop D Arden N
Full Access

Objective

To determine the use of oral anti-inflammatory drugs use in the year before and the two years after primary total hip (THR) or knee (TKR) replacement, and to assess whether this varied according to the Body mass Index (BMI).

Design

Population based retrospective case control study.